Ordinance No. 0448 02-02-1970ORDINANCE N0. 448
: �,. �
7
AN ORDINANCE TO AMEND CHAPTER 46 OF THE CITY CODE OF THE
CITY OF FRIDLEY (BOILDING PHRMIT FEES)
The City Council of the City of Fridley hereby amends Chapter 46
of the City Code of the City of Fridley, Anoka County, Minnesota,
to read as follows:
, 46.022. No wood framing for any structure may be spaced more than
sixteen (16) inches on center, except that in the case
of plank and beam construction where the same is of a type
approved by the Building Inspector as substantially fit for the
purpose, a wider spacing may be used.
�
46.2. That Sections 200.010 thru 208.050 of the Code of
Ordinance, City of Minneapolis, A9innesota as amended
December 31, 1968, is hereby adopted by reference and established
as a schedule of fees to be used in connection with the Building
Code of the City of Fridley with the following exceptions:
1. In Section 201.020 of the Code of Ordinance, City
of Minneapolis, delete reference to fireproof buildings and sub-
stitute Construction Type I, II and IV buildings as defined in
the Uniform Building Code 1967 edition.
2. In Section 201.040 of the Code of Ordinance, City
of Minneapolis, delete reference to non-firepxoof buildings and
insert Type III and V buildings as defined in the Uniform
Building Code 1967 edition.
3. Section 2QY.030, 201.080 and Sections 206.010 to
206.070 of the Code of Ordinance, City of Minneapolis are deleted
and are not a part of the City Code of the City of Fridley.
46.033. All buildings having any heating, air conditioning,
refrigeration or other mechanical equipment located
on the roof shall be required to have a stair leading to a scuttle
or bulkhead in said roof to make such equipment easily accessible
to maintenance and inspection personnel. The stair leading to the
scuttle or bulkhead shall be placed at an angie of not more than
60 degrees to the horizontal, with flat steps not less than six
inches in width and a minimum and maximum length of 24 inches
at the tread. �o riser shall be more than nine inches, and hand-
rails shall be provided on both sides of the access stairs. The
minimwn opening of the scuttle or bulkhead shall be not less than
six square feet in area with the minimum dimension being not less
than two feet. In no case shall this required access stairs be
located in or pass through the elevator shaft or elevator machine
room.
A suitable platform or walkway shall be provided if water
stands at the location of the mechanical equipment or in the
passage leading thereto. Proper permanent lighting shall be
provided to light the access route and the equipment. The switch
for such lighting shall be located inside the building near the
required access.
Appliances shall be located with at least six feet of
' clearance from the edge of the roof or similar hazards wherever
possible. If the clearance is less than six feet, a suitable
rail or guard not less than forty-two inches in height shall be
provided.
Each appliance shall have an accessible disconnect switch
and a 110-120 volt A.C. grounding type convenience outlet on the
roof near the appliance. Said convenience outlet shall be on the
supply side of the disconnect switch.
Protection from the weather shall be provided either by
the design of the appliance itself or by an enclosure around the
service area of the appliance only. This enclosure shall permit
easy entry and movement, shall be of reasonable height, and shall
have at least two feet of clearance to either side of the service
access panel of the appliance.
FRAMING
FEES
,
ROOF ACCESS•
AND ROOF
APPLIANCES
.�..,..�
.
J
,
s
�
.
ORDINANCE N0. 448 CONTINUED.
46.5. The following codes of the City of Minneapolis as found
in the Minneapolis Code of Ordinances, are hereby
_ adopted by reference:
Electrical Code being Chapters 140 to 146, inclusive,
dated February 21, 1969 and as amended to date.
Heating, Air Conditioning and Refrigeration Code being
Chapters 100 to 119 inclusive, dated July 1, 1960 and as amended
to date.
Pluinbing and Gas Piping Installation Code, being
Chapters 130 to 133, inclusive, dated July 1, 1960 and as amended
to date, except that Section 132.480 of the Minneapolis Code be
amended to permit the use of neoprene gaskets to be used on cast
iron pipes. Said exception to pertain to horizontal lines only.
Except that Section 113.77D (2) of said adopted code
be amended under Class B Vent flues to provide for a venting
capacity of at least 75,000 B.T.U. instead of the 50,000 presently
provided. (Ref. 297) (Ref. 408).
PASSED BY THE CITY COUNCIL OF THE CITY OF FRIDLEY THIS 2ND DAY OF
FEBRUARY, 1970.
. � �,� D �i��
MAYOR - JA°K 0. KIRKHAM
ATTEST:
� Q%��� C�`s�
CI�Y°CLERK - MARVIN C. BRUNSELL
First Reading: January 19, 1970
Second Reading: February 2, 1970
Publish.......: February 11, 1970