Ordinance No. 0448 02-02-1970ORDINANCE N0. 448 : �,. � 7 AN ORDINANCE TO AMEND CHAPTER 46 OF THE CITY CODE OF THE CITY OF FRIDLEY (BOILDING PHRMIT FEES) The City Council of the City of Fridley hereby amends Chapter 46 of the City Code of the City of Fridley, Anoka County, Minnesota, to read as follows: , 46.022. No wood framing for any structure may be spaced more than sixteen (16) inches on center, except that in the case of plank and beam construction where the same is of a type approved by the Building Inspector as substantially fit for the purpose, a wider spacing may be used. � 46.2. That Sections 200.010 thru 208.050 of the Code of Ordinance, City of Minneapolis, A9innesota as amended December 31, 1968, is hereby adopted by reference and established as a schedule of fees to be used in connection with the Building Code of the City of Fridley with the following exceptions: 1. In Section 201.020 of the Code of Ordinance, City of Minneapolis, delete reference to fireproof buildings and sub- stitute Construction Type I, II and IV buildings as defined in the Uniform Building Code 1967 edition. 2. In Section 201.040 of the Code of Ordinance, City of Minneapolis, delete reference to non-firepxoof buildings and insert Type III and V buildings as defined in the Uniform Building Code 1967 edition. 3. Section 2QY.030, 201.080 and Sections 206.010 to 206.070 of the Code of Ordinance, City of Minneapolis are deleted and are not a part of the City Code of the City of Fridley. 46.033. All buildings having any heating, air conditioning, refrigeration or other mechanical equipment located on the roof shall be required to have a stair leading to a scuttle or bulkhead in said roof to make such equipment easily accessible to maintenance and inspection personnel. The stair leading to the scuttle or bulkhead shall be placed at an angie of not more than 60 degrees to the horizontal, with flat steps not less than six inches in width and a minimum and maximum length of 24 inches at the tread. �o riser shall be more than nine inches, and hand- rails shall be provided on both sides of the access stairs. The minimwn opening of the scuttle or bulkhead shall be not less than six square feet in area with the minimum dimension being not less than two feet. In no case shall this required access stairs be located in or pass through the elevator shaft or elevator machine room. A suitable platform or walkway shall be provided if water stands at the location of the mechanical equipment or in the passage leading thereto. Proper permanent lighting shall be provided to light the access route and the equipment. The switch for such lighting shall be located inside the building near the required access. Appliances shall be located with at least six feet of ' clearance from the edge of the roof or similar hazards wherever possible. If the clearance is less than six feet, a suitable rail or guard not less than forty-two inches in height shall be provided. Each appliance shall have an accessible disconnect switch and a 110-120 volt A.C. grounding type convenience outlet on the roof near the appliance. Said convenience outlet shall be on the supply side of the disconnect switch. Protection from the weather shall be provided either by the design of the appliance itself or by an enclosure around the service area of the appliance only. This enclosure shall permit easy entry and movement, shall be of reasonable height, and shall have at least two feet of clearance to either side of the service access panel of the appliance. FRAMING FEES , ROOF ACCESS• AND ROOF APPLIANCES .�..,..� . J , s � . ORDINANCE N0. 448 CONTINUED. 46.5. The following codes of the City of Minneapolis as found in the Minneapolis Code of Ordinances, are hereby _ adopted by reference: Electrical Code being Chapters 140 to 146, inclusive, dated February 21, 1969 and as amended to date. Heating, Air Conditioning and Refrigeration Code being Chapters 100 to 119 inclusive, dated July 1, 1960 and as amended to date. Pluinbing and Gas Piping Installation Code, being Chapters 130 to 133, inclusive, dated July 1, 1960 and as amended to date, except that Section 132.480 of the Minneapolis Code be amended to permit the use of neoprene gaskets to be used on cast iron pipes. Said exception to pertain to horizontal lines only. Except that Section 113.77D (2) of said adopted code be amended under Class B Vent flues to provide for a venting capacity of at least 75,000 B.T.U. instead of the 50,000 presently provided. (Ref. 297) (Ref. 408). PASSED BY THE CITY COUNCIL OF THE CITY OF FRIDLEY THIS 2ND DAY OF FEBRUARY, 1970. . � �,� D �i�� MAYOR - JA°K 0. KIRKHAM ATTEST: � Q%��� C�`s� CI�Y°CLERK - MARVIN C. BRUNSELL First Reading: January 19, 1970 Second Reading: February 2, 1970 Publish.......: February 11, 1970 n ELECTRICAL� HEATING AN PLUMBING � � �