RES 1965-172 - 00011491236
RESOLUTION -N0. 172 -1965
A RESOLUTION ORDERING TAE REPAIR OR REMOVAL OF THE STRUCTURE LOCATED
AT 5612/5614 - 6TH STREET NORTHEAST IN THE CITY OF FRIDLEY BY REASON
OF ITS BEING A HAZARDOUS STRUCTURE
WHEREAS` on August 13, 1965; James H. Hensley, City of Fridley
Health Officer and Building Inspector, inspected the property and
reported the following conditions:
1. Improper storage of garbage.
2. Improper burning of garbage.
3. Garbage littered on the grounds.
1:. Front and rear premises littered with trash and refuse.
5. Overgrowth of weeds.
WHEREAS, on August 23, 1965, Leonard Eichmiller, City of Fridley
Electrical Inspector, inspected the property and reported that
electrical outlets in the kitchen of each dwelling unit are poorly
located necessitating the use of an excessive number of drop cord
connections and thereby causing a hazard.
WHEREAS, the said Electrical Inspector reported that no outside
light exists over the rear entry to provide security for the tenants
and enable users to avoid hazards at the rear of the dwelling units at
night.
WHEREAS, the said Electrical Inspector reports that the proper
remedy of these existing conditions is the installation of additional
20 ampere capacity circuits and outlets in the kitchen and the
installation of an outside light over the rear doorway with an inside
switch.
WHEREAS, on August 31, 1965, William Sanden, City of Fridley
Plumbing and Heating Inspector, inspected the property and reported
the following conditions which in the opinion of the Plumbing and
Heating Inspector impair the required 1 -hour fire rating of the
furnace rooms and which require the following or equal repairs:
EXISTING CONDITIONS NECESSARY REPAIRS
1. The exhaust stack of the furnace 1. Cover door head with cement -
passes within 6 inches of the door asbestos or equal non -
head, c_ ' said door head being made combustible material.
of combustible materials.
2. The doors on the furnace rooms are 2. Install 1 -3/414 solid core doors
not solid core doors. with proper louvers.
3. The louvers to the furnace rooms 3. Equip the louvers with fire
are not equipped with fire dampers.
dampers.
4. The sheet rock on the walls of 4. Install sufficient sheet rock ,
the furnace rooms measures on both sides of wall to make
3/8 inch thickness. 2" thickness, or sufficient
sheet rock on the interior to
provide a 1 -hour fire rating to
the furnace rooms.
237
RESOLUTION N0. 172 -1965 (Continued)
WHEREAS, on August 24, 1965, Allen Jensen and Clarence Belisle, City
of Fridley Building Inspectors inspected the premises and reported the
following existing conditions requiring the following or equal repairs:
EXISTING CONDITIONS
1. The foundations are cracked in
' various places. The cracks have
not been repaired allowing water
to seep into the crawl space.
2. The center beam has an inadequate
number of supports.
J
3. The crawl space is open to the
outside allowing water, rodents
and vandals to enter at will and
heat to escape.
4. The floor tile are loose, cracked
and broken. Water has entered and
soaked the floor underlayment.
There is no covering or flooring
over the underlay (sub - floor) other
than floor tile. (Single floor
construction.)
5. Ceiling joists lifted in small
areas as a result of the storm.
Ceiling water damaged as a
result of storm damage.
NECESSARY REPAIRS
1. Point up the cracks as necessary.
2. Pour 5 concrete pads equally
spaced under the beam and build
supporting columns out of masonry
on the concrete pads.
3. Install doors with locks on the
crawl space openings.
4. Strip and examine sub - floor.
Replace sub -floor as needed.
Install Lrc plywood over sub -
floors and then install new
tile floor covering or other
covering as required.
5. Reset and renail all loose
joists. Remove and replace
damaged ceilings and ceiling
insulation.
6. Walls have cracks and holes in a 6. Remove sheetrock wherever
few places. Possibly due to evidence of damage exists,
storm damage making the condition renail loose studs and recover
of some of the wall studs doubtful. with new sheet rock.
7. The roofing was damaged by the 7.
storm. New roofing was installed
without proper preparation of the
sub - roofing. Workmanship rejected:
Remove all roofing material.
Examine roof sheathing and repair
and renail roof sheathing and roof
components as required. Install
new roofing over proper roof
sheathing.
8. The siding on the south and west 8. Remove siding on south and west
walls is cracked, broken and walls and replace with new siding.
gouged. A lack of proper Repair any damaged shakes on other
maintenance is evident. walls. Paint as necessary.
9. The building suffers from a lack of 9. Scrape and reputty all windows as
proper maintenance. The window needed. Scrape, sand and repaint
putty is dried, unpainted, cracked entire structure as needed.
and broken loose. Facia, cornice
and trim need painting to prevent
deterioration.
10. The owner has allowed the tenants 10. Provide proper off- street parking
to park on the weeds surrounding for each dwelling unit. (the
the building in lieu of providing ordinance requires paved off street
off- street parking. parking for 2 cars per dwelling
unit in the rear with paved driveways
for new construction.)
11. The lawns are weeds. 11. Sod the lawns properly.
238
RESOLUTION NO. 172 -1965 (Continued)
NOW, THEREFORE, BE IT RESOLVED, by the City Council of the City of
Fridley, as follows:
1. That a notice pursuant to Minnesota Statutes 1162.39 to 462.40
concerning hazardous buildings be preoared by the City Attorney and
City Manager; that said notice give the owners until December 20, 1965,
to remove said hazardous condition or make the necessary repairs to
correct the defects enumerated by the City Health Inspector, the
City Electrical Inspector, the City Building Inspector, and the
City Plumbing and Heating Inspector; that said notice be served
on the owners as provided by said Minnesota Statutes and the
City Attorney is authorized to proceed in District Court Anoka
County to enforce said notice and order if the necessary
corrective action is not taken by the owner.
PASSED AND ADOPTED BY THE CITY COUNCIL OF THE CITY OF FRIDLEY THIS
20TH DAY OF SEPTEMBER, 1965.
WJ rl9k
MAYOR - Willi J. Nee
ATTESTS
AW
CITY C - Marvin C. Brunsell
RESOLUTION NO. 173 -1965
A RESOLUTION ORDERING THE REPAIR OR REMOVAL OF THE STRUCTURE LOCATED
AT 5618/5620 - 6TH STREET NORTHEAST IN THE CITY OF FRIDLEY BY REASON
OF IT BEING A HAZARDOUS STRUCTURE
WHEREAS, on August 23, 1965) J=Ws H.`Hwmagyy City of Fridley -'
Health Officer sand Build1mg;Inspector4nspected the pretty' and_
reported the following conditions:
1. Improper storage and burining or garbage.
2. Front and rear premises littered with trash and refuse.
3. Overgrowth of weeds.
WHEREAS, on August 232 1965, Leonard Eicbmiller, City of Fridley
Electrical Inspector, inspected the premises and reported that the
electrical outlets in the kitchen of each of the dwelling units are
poorly located necessitating the use of an excessive number of drop
cord connections and thereby causing a hazard.
WHEREAS, the said Electrical Inspector reported that no outside
light exists over the rear entry to provide security for the tenants
and enable users to aboid hazards at the rear of the dwelling units at
night.
,iHEREAS, the said Electrical Inspector reports that the proper
remedy of these existing conditions is the installation of additional
20 ampere capacity circuits and outlets in the kitchen and the
installation of an outside light over the rear doorway with an inside
switch.