Loading...
AF - 42840SUBJECT P O.� City of Fridley . 2 5 6�� AT THE TOP OF THE TWINS gU I L D I N G P E R M I T r � � � �' COMMUNITY DEVELOPMENT DIV. fJ r � ~ � PROTECTIVE INSPECTION SEC. �j��p 1 i � � /'�'1 � CITY FIALL FRIDLE� 55432 NUMBER REV DATE PAGE Oi APPROVED BY �""� � �'� 612-571-3450 910-F15 11/18/97 � � JOB ADDRESS 132 Christenson Court NE t LEGAL LOT NO. BLOCK TR71CT OR ADOITION SEE ATTACHED DESCR. 14 1 Christenson Crossing SMEET 2 PROPERTY OWNER MAIL ADDRES$ 21P PNONE Rottlund Company Inc 2681 Long Lake Rd, Roseville MN 55113 638-0500 3 CONTRACTOFi MAIL ADDRESS ZIP PFIONE IICENSE NO. Same 1335 d ARCFIITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAII ADDRESS Z�P PHONE LICENSE NO. 8 USE OF BUILDING Residential Townhouse & Garage 7 CLASSOFWORK NEW ❑ ADDITION 0 ALTERATION O REPAIR O MOVE � REMOVE � 8 DESCRIBE WORK Construct a 38' x 25' Townhouse and a 22' x ZO' Garage 8 CHANCiE OF USE FROM TO STIPULATIONS See notations on plan. Paid $375.00 park fee. :�%����� � � Before di$gir?g caSi fior all utility locafions �`EPARaTE PERMITS REQl�tREO F0� � a5a•o�o2 �lRIN6, HEATING, p��M81NG AN� 51� REQUIRED BY LAVif � TYPE OF CONST. OCCUPANCY GROUP OCCUPANCV LOAD SEPARATE PERMIFS ARE REQUIRED FOfi ELECTRICAL, PLUM8ING, HEATING, VENTILATING OR AIR CONOITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION 20NING' SO. FT. CU. FT. AUTHORI2ED IS NOT COMMENCED WITHIN 80 DAVS, OR IF CONSTRUCTION OF WORK IS SUSPENOED OR ABANDONEO FOR A PERIOD OF 120 OAVS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTFEET PARKING 1 HEREBY CERTIFV THAT I HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS Of LAWS VALUATION SUFTAX Fire SC AND OFDINANCES GOVEfiNING THIS TVPE OF WORK WILL BE COMPLIED 118�3LZ �5�.16 WITH WHETHEA SPECIfIED HEflEIN OR NOT. THE GRANTING Of A PERMIT � LLS.3L DOES NOT PFiESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL TNE pERMIT FEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- @ STRUCTIO THE PER FMANCE Of CONSTRUCTION W982•2S $950.00 „ PLAN CHECK FEE TOT L FEE � -��- % Licens C $5. 2,114.73 + PF SIG A UREO ON'RACT ORAUTMOR12EDAGENT IDATEI EN R P VALI T D THIS IS YO/UR PERMIT `. /i � r / � SiGNATUREOFOWNEi7iiFOWNERBU�IDER� �DATE� BlD �NSp �1l.TE NEW ADl�1V ALTER � �� [l CITY OF FRIDLEY � SINGLE FAMILY A1vD DUPLEXES R-1 AND R_2 BUILDING PERMIT APPLICATION Effective 1/1/97 �� � �� � � ; � ConstructionAddress:_ l32 G��i�S'7-�j(/50 CP1U/�T�` � Legal Description: G�%� /57T�j0 �O�Si/l/G7 � LDCfC / � �j7' / � --7- , Owner Name & Address: � uE �T�t c►�� -��,, ��l ( N�. Tel. # �, �--���_ Contractor: S��fYIE MN LICENSE #_ I 3� Address: ,'��o$ � ���� ��F '�yc��� J � �E , Nl i�{ �, 51! Tel. # _ !� �8 � d JGp Attach to this application, a Certificate of Survey of the �� F"' gd'�� �� s lot, with the proposed co�truction drawn on it to scale. ��� % �3 u,�w/�� i221 �a��,$=����'Y�� ' DESCRIP'rI4N OF IlVIPROVEMENT u��� �� ���� � 3 r Go,1`l � ��y Y�6. � LIVING AREA: � Length 3�� �(' �� Width �S� I� Height .�. Sq. Ft. l�o� Z GARAGE �REA: Length �a-� O`' Width o`�D'-O �' Height 2/ =��� Sq. Ft. ��% �� DECK AREA: Length Width HgtJGround Sq. Ft. .�( a�'� `�9 OTI�R: _ � _ _ . � '..� �,��f, ��c� . � �r g�3 � � Constniction Type: R��32/��U7'1/kt� Fstimated Cost: $(�Z,7�1 /�QO . (Fee Schedule on Back) Driveway Curb C�t '9Vidth Needed: Ft. + 6 Ft = Ft x$ _$ �ATE: l� ° 29 -�1 �7 APPLICANT: �J� (�� Tel. # (� �� - �S� 2 Permit Fee Fire Surcharge � tate Surcharge SAC Chazge License Surcharge Driveway Escrow �rosion Control ?ark Fee 3ewer Main Charge TOTAL �TIPULATIONS: � Z. 2� $ l( � $ ,/� $ d� $ �� $ CITY USE ONLY Fee Schedule on Reverse Side .001 of Permit Valuation (1/lOth%) $.50/$1,000 Valuation $950 per SAC Unit � $5.00 (State Licensed Residential Contractors) Alt. "A" or Alt. "B" Above $ �50.00 Conservation Plan Review . $ � Fee Determined by Engineering �� � � � a � � $� Agreement Necessary [] Not Necessary j] $ o �'� i I3UII.DIi\'G I'EiLVIIT FEE SCFiEDULE 1'lle Chief Building Official shall, before issuing perniits for the erection oC any building or structure, or fi�r an}� addition to any existing building or structure,� or for any alteration or repair to any existing building or sttucture, upon application therefore, require the payment by the applicant for such permit of fees to the amount herein below set forth and in the manner herein provided to-wit: . . TOTAL VALUE $1 to $S00 � $�O1 to $2,OOp 52,001 to $25,000 $25,001 to $50,000 �50,001 to $100,000 $100,001 to $500,000 �500,001 to $1,000,000 $1,000,001 and up FEES $21 iMinimum Fee is $21 plus surcharge) $21 for first $500 plus $2.75 for each additional $100 or fraction thereof, to and including $2,000 $62.25 for first $2,000 plus $12.50 for each additional $1,000 or fraction thereof, to an�i including $25,000 � , $349.75 for first $25,000 plus $9.00 for each addi6onal$1,000- or fraction thereof, to and including $50,000 $574.75 for. first $50,000 plus $6.25 for each additional $1,000 or fraction thereof, to and including $1Q0,000 $887.25 for first $100,OQ0 plus $5.00 for each additional $1,OOO�or fraction thereof,.to and includi.ng $Spp,000 $2887.25 for the first $500,000 plus �4.25 for each additional $1,OU0 or fraction thereof, to.and including $1,000,000 �• $5012.25 for the first $1,000,000 plus $2.75 for each additional $1,Q00 or fraction thereof DRTVEWAY DEPRESSION ESCRO�V (Concrete C�rb Streets Only) Alternate "A": Removal and replacement of curb and gutter only - Driveway width plus 6 feet times $13.50. Alternate "B": Removal and replacement of curb and gutter and install a 3 foot wide approach with 6 inch depth - Driveway width plus 6 feet times $15.75. . . VERIF�CATION OF FOUNDATIO`T . Pernii�s for construction wilI be issued a minimum of 24 hours from the time of application to allow for pro�er rc��ie«• of the proposed structure and of the construction site. r1 t:;e�tilicate of Survey of tlic lot, showin� the location of the foundatio;� ��rice it has it has been constructr•;! �i�i :��� r�quired h�fore �rc��ecding �vith the framin�. �* � * PIONEEp * ang neer **** LAND SURyEYORS • GYN, ENpNEEFtS LAND PLANNERS . WVpSCAPE ARCHITECTS Certificate of Survey for: House Address: House Model: 2422 Enterprlse Drive Mendota Heights, MN 551T0 (812) 881-1914 FAX:681-9488 625 Ffighway 10 N.E. Blalna, MN 55434 (612) 783-188D FAX:783-1883 THE RO TTL UND COMPANY _ 132 C.tir�istenson Court Halston A CHRISTENSON CO URT /� , r�/ / �O o � �°��O'� 15� � oF a�oc�c� _ /� 851.0 /A 14 '� ROp � �� F�� so�Ry / - - �s°oo �O oo�� � D �� �r o0 C �R�� g 13 \�` roP oF e�oc�c- aP� O r3� O � ��O.o° � �O / \ � V � �---- �� - � � SATELLITE LANE x sao.o Denotes Exlsting ElevotJon � Denotes Proposed Elevotfon �,RppO.SED BUILDWG ELEVATIONS —�- Denotes DraJnage Flow DfrectJon � Denotes DroJnoge & Utplty Easement Gorage Slab Elevation: 1.5 (at door) �� �@llOt@3 Monument NOTE: Propoaed buAding ait� grad(ng is in oeeardones �rith the t Denofes Offset Iron BearTngs shown are assumed 9roding plans approvsd by the c(ty enginear. NOTE: Contractor muet vsrity eq dimenslona dc driveway dealqn. LOT 14 , BLOCK 1 CHRISTENSON CROSSING ANOKA COUNTY. MINNESOTA We hereby certify that this survey, plan or report wos prepared by me or under my direct su eMston and that I a duly ticensed Land Surveyor under the laws of the State of Minnesota. Dated this ��� day of ���a�� A.D. 19� Signed: PIONEER ENGINEERING, .A. ----� S c a le : 1 inch = 3 O feet _,_ BY �, Robert B. Sikich, L.S. Reg. No. 14891 or � 16190.19 TRB Terrence E. Rothenbacher, L.S. Reg. No. 20595 MAY-12-199? 15�41 ti rn � � c � c O .� � Z � O `'� 3 � � ~ w � > C7 � Z � � U S O O U p � 4 Z �� � _ ��„ Z y <� z G!) Z H O z� a° • �o ��� �¢ 0 �Z oQ �z Z � O �ti U � J Q L�l d Q � 0 O N U � � Z z j N d � p �� � � a� Z �����c � _ � � 1 r , � ti �1 � a.� � � �J I (��, v 1 � C.%� � � � � � 0 ¢ m � W � � � W _ � .� d � CITY OF FRIDLEY v c � � t � � � Y U N ` U � �w � U m .� � s • � � � — m� 3 .c �° i 0 � '3 .`QC � y a c d c�a O O N � C.) 'i3 m OoU6 A cC I .0 ` � .O 'p„ v, � ic � C = v y � � a � �3°oH ���s � � p � c Z3 � � O � � � ���_°� � � m � � �n,a o �L .` � � .� _ � ° �, � � v � Q � a� cu . � N i.�. i � J � � F � I o � �� � � � $ � � � � 0 0 � � 1 ,,,� 'd v ti � � � 7 � � � O C � � � Z �LO� �ti� � C � � y � �, m � � Z :a � a.ti ,c m �¢�.a � C O N Uf j tA cti a�a c� h ,.r � O z i�- � � a � � � ., ¢ 0 w � � � Z � � m � O � E- � LJJ . ` \� � � `� $ o g O Q N � � � v� c � � C7 Z 0 m C� N m � ¢ t rn c c 0 � c U a . �b 1 � � � ^ � � = C p �Z W � � N J �� a � � u C � C C � � U � � U =ti _ � ' l,/1 � � c� � '�' �v ._ m =Z � `o d � Z1=m.ti Z N N � lu _ E Z � � � m c m m 612� � � 128? P.01�2 � � � � \. �� � � � .. � � �- � 8 Z IJJ _ O\ qn • ( � v J � � �� �: U o¢D 0 � O C � 0 0 � m Q � � � � Q `� `o �. � � j r O o ¢ Y � o` C�i c � � Q c Q, � a O c � = � �. � m o E � E c�nv. U � � � uJ � � V7 J � � �4 � O w v� � �� � v� � a� O c � 0 a� � � U c ►-t- i W s � � o � � Q 1-- � w w �w a � m �� c�i U Z o m � a O U ¢ s J a tL (WS'.' � r � � � � .uN O N � � � C Q . O N � � cs C a 'c � � o .� `o � c � c o iII LL' tn O O o � � U � � w � c. 0 ZV a�i �.. ?"„ � ¢ �� Client: Address: City: Phone: Fax: Comment: Rottiund Homes 2681 Long Lake Road Roseville� Minnesota 55113 638-0500 638-0501 YOUR BUILDER FOR LIFE Project Name: Reference Ciiy: Daily Temperature Range: Latitude: Elevation: Winter: Summer: Medium 44 Degrees 834 Feet Outdoor Outdoor Indoor � Bulb Wet Bulb fl�1�tIL01. -20 N/A N/A 95 75 50% Total Building Supply CFM: 664 Square feet of room area: 2,054 Company: Representative: Address: Ciiy: Phone: Fax: Comment: Minnesota Indoor Grains � Bulb Diff�r�nc� 72 N/A 75 36 �f�-�� ro ��( Flare Hea�ng & Air conditioning, Inc. Randy 9303 Plymouth Ave. N. Golden Valiey, Minnesota 55427 542-1166 542-3101 YOU CAN FEEL THE DIFFERENCE CFM per square foot: 0.323 • Square feet per ton: 1,197.276 Total heating required with outside air: 41.498 Btuh 41.498 MBH Total sensible gain: � 14,608 Btuh 74 % Total latent gain: 5,147 Btuh 26 % Total cooling required with outside air: 19,755 Btuh 1.646 Tons (based on sensibie + latent) • � 1.716 Tons (based on 75% sensible capacity) Caiculations are based on 7th edition of ACCA Manual J. All computed results are estimates as buiiding use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � � Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 4A Window Double Pane & Storm Clear Glass Wood Frame 189 5,929 0 5,389 5,389 11 C Door Metal Polystyrene Core 40 1,730 0 444 444 121 Wall R-19 + 1/2" Asphlt Board(R-1.3) 1,495 7,564 0 1,940 1,940 15B Wall 2-5' Below Grade 8/12° BIk+R-5 530 3,608 0 0 0 16H Ceiling R-38 Insulation 1,027 2,457 0 1.175 1,175 21 A Basemt Floor 2' or More Below Grade 1,027 2,268 0 0 0 Subtotals for structure: 4,308 23,556 0 8,948 8,948 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 � Appliances: 0 0 600 1,200 1,800 Lighting: 0 0 0 : Ductwork: 0 0 0 0 0 ; Infiltration: Winter CFM: 87.3, Summer CFM: 58.2 229 8,834 1,424 1,280 2,704 � Ventilation: Winter CFM: 90.0, Summer CFM: 90.0 0 9,108 2,203 1,980 4,183 � Sensible Gain Total: 14�608 �, Temperature Swinq Muitiplier __ X1.00 Buildinq Load Totals� 41,498 5,147 14.608 19,755 fotal Building Supply CFM: 664 � Square feet of room area: �L,054 CFM per square foot: 0.323 Square feet per ton: 1,197.276 Total heating required with outside air: 41,498 Btuh 41.498 �MBH Total sensible gain: 14,608 Btuh 74 % Total latent gain: 5,147 Btuh 26 % Totai cooling required with outside air: 19,755 Btuh 1.646 Tons (based on sensible + latent) 1.716 Tons (based on 75°/a sensible capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � Component Area Sen. Lat. Sen. Total Description Quan Loss Gain Gain Gain 4A wndow Double Pane & Storm Clear Glass Wood Frame 189 5,929 0 5,389 5,389 11 C Door Metal Polystyrene Core 40 1.730 0 444 444 121 Wall R-19 + 1/2" Asphit Board(R-1.3) 1,495 7,564 0 1,940 1,940 15B Wall 2-5' Below Grade 8/12" BIk+R-5 530 3,608 0 0 0 16H Ceiling R-38 Insulation 1,027 2,457 0 1,175 1,175 21 A Basemt Floor 2' or More Below Grade 1.027 2,268 0 0 0 Subtotals for structure: 4,308 23.556 0 8,948 8,948 Active People: 4 0 920 1,200 2,120 Inactive People: 0 0 0 0 0 Appliances: 0 0 600 1,200 1,800 Lighting: 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: �nter CFM: 87.3. Summer CFM: 58.2 229 8,834 1,424 1,280 2,704 Ventilation: Winter CFM: 90.0, Summer CFM: 90.0 0 9,108 2,203 1,980 4,183 Sensible Gain Total: 14,608 Temperature Swinq Multiplier• X1.00 Zone Load Totals: 41.498 5,147 14,608 19,755 -Supply CFM: 664 � CFM per square foot: 0.323 Square feet of room area: 2,054 Square feet per ton: 1,197.276 � . ... ..... .. ..... ....... ... . ......... .... . ......... ::: •nv.:v.•.r :..:. �v •: •:::. ••::. •:.s. •.•.•. •. :.v:. •:::::: •:x.�.� �•v.•.• . �:e.; �r.,.,....;••,.iii•:�:i�•i.•}::+v:+.;•�\ \' .'��'. "?•:'i'•i"•::: :;•.; :v,.•. ...\ ..::...; .. .:•'.�: •.• •: k:.•. vvh•:.•.•::.'�.•TV.•\h. . p♦ \ . .� 1 �'�. •::;.1.�.. 'v ♦ . \y� r::::.:::.•. •�i\t:.};.;};.x;.v:•.:C•:..:v,•.,.,.•:::::::.:.•.•:::.•::.�v:{%'•i:n;•: •:•': �.,...::::: :w.•.... v ''c... .: •\va.��. .... �. .\.'•.i•°.:+. �\. v:.�:: V •.•:.5••\.k� . �n. '�.� ..8..> >�\:o•i::.:bYv'-\ < . \vi�� .\ti�,`.tii:ti:y:\\\,. },• ♦..Y.... •>.:`•:.; .•.•1: . \ ..\e.. �.vb. n\ .••4 ��,�• n•.•::.vv::.�4v...n....n�.v .. . .. . .:::::::.v.w:.•: L�•i::•. . ...v .... .��:�.•:.�••:.•.•.•vw.: n �v �.v.;.•.e:`•:. vv.•? • .. v.. ��.. . n:.;;:n,•; :, •.;•.;.�}w, •S -. 1 +?•`.•: ..�. . \... .. �r, \.•::8:•:v:? .. E` :. v .�•:•. �t' .�\\+:ti: .o ..1 �\ti�\•ir �, �}.:v'Ctid4.��. ...i. .\ • .. ::x.•.•.•:.•.•.• t•::..•.vv�� �.•�.••4: •. •:.v.•n-.:: •: •.......v. n�•:•.•\•\ . vx:. ... �•::?:x::�.w..�.vv.. .v. 4 ••�.\�•:\i�.8:.•. ♦ .6 ;,y�„ .,.}.:: •.h ° � "�. .4.�... .. . . . �:: ! .� :C •••:�. . . 'w ti::::'7 .0.4,....:fi: v}:>.•..; ;...n v..`'���'.'v. :.••)i•:.::•>�:. .:b. .o ti2\laa•.v: :,....+:�\\\•:�+.ti�:4: • v:. •..i:•.:i•:•' i•., •:.. . � ..� :i. . .; .;, . . .} �...:.nv. ........v.},6., ., v,•�ry•:•\\i4:�V�•.�•p•..'% � . .r..•n•:.. �'•.•x .4•:�..\•..•:�:•i�•:�'+S'•\��.. . \ . ...4....n \n\\�'�i:•:•Y.:�:•:•. � :.. . . ♦... ..:.,..:•.!.•:::.•:�:k:a:•::.•.`+.'�. k.'w�'..,.:�`••a:ca>::•x•::•:..k ............'.:.�..t.......••.V.::c.'�:,.�a. ... ... \�.....,:..,.,........roa',....,..,� c\.+..:ti:::.......\.ti� .`'!._ ... . . .. • t\•,�.::�.........n.. .. ;..�.. .....�.. :..W ... ........•::::.. •r::: \::,v,.; ..�.. c;��.,'>.\v ••r... ... .t �...... . ,;..>.. •.�.,:2..'...:.,••,,.... � . ... ...�.., . .. .�.....�.....��.......�..t .\...... .\..�............\...�.�.... .\.. ♦\v..... �.�....•::...�v.iv1. ♦ •�..v�:•?...'}h•.•..:�.•:v.•'•�y}::•:i:•::v�v�.,v�:V.,v;4<_.:�.\1.� :v:•.v•n'�..o:•.•�V J"o�:i:?;•�:-�!•n•.E..\�:,•`,�,r :+. . .�. . .'ti.•..�.•.,.•::,: •:: . •:w:�� v .s.�:::. •. •. •:...o.. .;a\:.,•: \\.. ..:y,..+�..+..5. •:xb..... •.... ,� ..::.v...••..�.•..,+ti`s:..:::. •. c 1,�:�-.a \.....�\\_.c.w). •..•.•::!.�:.Z.......x.. .Sc .:\..; . :il,�,�,�,\�•:::x•:.•.•.•.ss•.�:.•.•.�:: �. v..:::::h �"•:::::.v�}:i:•i:•.'h�::.•:^....., ''�.\.•.�.. •.i•:•:•'•}�:'v:L•:�::\..•.• ...ti .E., h:ti\2..,:��.•.•'.v.•.•'.vx.v....4:•.\\.fi.`•R�•i:•:r •v.. .... �\... \ti.�. �Cv:•::ii.+:i•.v.i...... \ ..u. . .. :V�.. �: •::::::A'J•..\..........v...... . ...\. v\.�....... .v .... ............. v\ �.ti�h .... 4. ...n.....� . .... . ..... Total heating required with outside air: 41,498 Btuh 41.498 MBH Total sensible gain: � 14,608 Btuh 74 °/a Total latent gain: 5,147 Btuh 26 °/a Total cooling required with outside air: 19,755 Btuh 1.646 Tons (based on sensible + latentj 1.716 Tons (based on 75% sensible capacity) � ., � � x ! e ADDRESS ��'_ OCCUPAN��`' HEAT LOSS SOLD BY ' Elsef►icol Work Br6 ,, � I�'�I . .. -...-.(�--r-�� TE TYPE OF HEAT GA FA .,,w i r:;;, . �. `Ft '� !�, W. ;q� :., ,. . :.. .s:. ...::.tY ^'� �_.. i . . .., , . � ,.. ' _ d., HOUSE HEA I G 7E5T RECORD ���✓ ���' - o ,, PT. FLOOR CITY �SUBURB OWNER iNST. _ ° - INSTALLED BY Gos Lins Br _HNf 57EAM SRA6E HTR. UNIT HTR. OTHER GAS ESI � MAKE MAKE OF BURNER _ Mod�� Modal S�rial � Ma:. BTU:Rating — INPUT MAKE OF FURNACE �, Model . COMTROLS : 4 :... .s �-_ ., ti k : THERMOSTAT r" �Heat vq V4nf Siza ,� Volvs ��,---��c�'t°��''° KIND OF L Limit Limit S�Hiny Fon Setting _ _ Oraft Hood _ Filtars CON V E RSI ON Chimnsy Location � r � losid� � Outsids Pllot Typs /'����-� � • Chim�ey Conshudion Pilot Make �"/�-�"��-��-� = Pilot Model �� Smeke Bomb Wiring �'� - Pilot Timing � Draft ' Tsst Teq L.W. Cut Off � Door Pressuro Lightiny Inat. ",� r / Prossuro ` P eet COZ Dcre Tssted _ Input CFH Pe�eset OZ Compurty Testing Smck Temp. Peresnt CO Nams of Testsr Form 235 1 " `� n Of Of � l0 7 � � � c O a� �i � W � 0 Z O F W � w Z Z � a' � 0 •� � � `m Z u' > � o O � � � � � •� � U m u. �n U � � � ('� � � W Q 0 Q m O � � � 0 w � O Z w � W 2 X � � Z m � J a � � 01 � L'..lJ � 9 � � � �� N c 3 O � � ¢ "0 a� N � � C 'o .� m � ,\ � l� � �.. ' a � O � Z F- � � w a � � � >- / Z ¢ � a � O U � m Z � m W � Z � � nJ. v� N 0 U 'O N � E w � � 1 � � 0 z w F- � O� O �� �� 000000000000 0 000000000000 0 � v ui n� r• n o i: o 0 o ui � � � � � � � � � � � � a� � I I I I I I I I�� I Z I N N } � � � '� � a� � � � .� t � Y * LL c�o a � cyo °: 3 � f- a °� � c Z� c �� rn W � a�i d o� � � S � 'azi � °: °: � � o`. .- c d �p •y d o�� �o ��� � c a � d� a� d � a� p � a�' p m r° a� E- __ �a �` � m �.�0 3r3 a.. � ��p a N� N � � l0 7 f�0 � � N N V � Z O m m U ac m 3� 3 C7 (7 m V` � � ' I I � � 0 ; C F 'u. . � z 0 F � J Q � 0 C Ql0 ` Q Q = w o °o � � � m ° o � Q a� � � � W > �" O � C � � Q � m � 0 c I t rn � � a m '0 N O a a ¢ o � � � � m �f � t � 7 � m � � w w LL � � � _ CITY OF FRlDLEY FRIDLEY MUNIC[PAL CENTER • 6431 UNIVERSITY AVE. N.E. FRIDLEY, MN 55432 •(612) 571-3450 • FAX (612) 571-1287 March 9, 1998 Rottlund Homes 2681 Long Lake Rd Roseville, MN 55113 Re: Final Inspection at 132 Christenson Court NE, Fridley, MN Dear Sirs: A final inspection was conducted on March 6, 1998 for the above noted townhouse. We found that the construction of the building complies, to the best of our knowledge and belief, with all the requirements of the building codes of the City and the State of Minnesota relating thereto, and permission is hereby given for the occupancy of said building. If you have any questions on this matter, please feel free to contact me at 572-3603. Sincerely, ��f�_.. , � .. .. . Building Inspector : t_ ���_