Loading...
AF - 42860SUBJECT P City of Fridley � � � � 2 AT THE TOP OF THE TWINS g U I L D I N G P E R M I T r � �• COMMUNITY DEVELOPMENT DIV. �� �� r � ~ � PROTECTIVE INSPECTION SEC � � � / ' � /'��1 � CITY HALL FRIDLE� 55432 NUMBER pEV DATE PAGE OF APPROVED B� �"'"'� � ��' 612-571-3450 910-F15 10/30/96 / / JOB ADDRESS 139 Christenson Court NE t LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 3O 1 Christenson Crossing SHEET 2 PROPERTY OWNER MAIL AODRESS Z�P PHONE The Rottlund Co 2681 Long Lake Rd, Roseville MN 55113 638-0500 1335 3 CONTRACTOR MAIL ADDRESS Z�P PHONE LICENSE NO Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAII ADDRESS Z�P PHONE LICENSE NO 6 USE OF BUILDING Residential 7 CLASS OF WOHK Q NEW 0 ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE R B DESCRIBE WOHK Cnostruct a 66' x 24' Townhouse and a 22' x 12' Garage 9 CHANGE OF USE FROM TO STIPULATIONS See notations on plan. Paid Park Fee of $375.00 TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD SEPARATE PERMITS ARE REOUIRED FOR ELECTRICAL. PLUMBING, HEATING. VENTILATING OR AIR CONDITIONING THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED Ofi ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTFEET PARKING I HEREBY CERTIFV THAT I HAVE HEAD AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORREC7. ALL PROVISIONS OF LAWS VAIUATION SURTAX Fire SC AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED @ WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT W67 f 372 �33. 6$ �67.37 DOES NOT PRESUME TO GIVE AUTHORITV TO VIOLATE OR CANCEL THE pEqMIT FEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- STRUCTION OR THE PERFORMANCE OF CONSTRUCTION. �CS7.ZS �gOO.00 PLAN CHECK FEE TOTAI FEE � �----- `� � � License SC $5.00 $1,693.30 + PF S�GNAIUHE OF CON'RACT R AUTMORIZED AGENT IDATEi WHEN PpOPEfiLY LIDATED THIS IS VOUR PERMIT ^ � � �'��--��'G� S�GNATUAEOFOWNEFlUFOWNEABUILDEAi i0AT6 BLD '�NSP ��a1E NEW ADDN ALTER �] �] [l CITY OF FRIDLEY SINGLE FAMILY AND DUPLEXES R-1 AND R-2 Building Permit Application Effective 3/1/96 ConstructionAddress: % �j q ,,.) � ��:n� �� ►� �,T' Legal Description: �� i �j�k �'LN�,�-��NhP�� �° ���1 NC� Owner Name & Address: �-�L,�ti� Hp ��5 Tel. #%n '?��j� Q�Op Contractor: �p�T�►� j-�p (� MN LICENSE # l 3� -�"j Address:�lo�'1 l.h�C� I A1� �AD � �1�11.1.� ,� lill�i, �113 Te1. #�o�g —���CX� Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. LIVING AREA: GARAGE AREA: DECK AREA: OTHER: DESCRIPTION OF IlV�ROVEMENT Length � 1� =0 ` Width 7�] = ��� Height p� p" Length ` %Q" Width IZ�O" Height ��'�" Length °-- Width � Hgt/Ground — � � � io�� , r� Sq. Ft. ,� X,� �� . Sq. Ft. o`�fny xlB•��G.`� 5q. Ft. � Corner Lot [�([ Inside Lot [] Ft. Yd Setback Side Yard Setbacks Tyge of Construction: ���` ��j"rl �-1 L Estimated Cost: $ r^�s_ �, �" Approx. Completion Date: y�9� . �� 37aZ• 1�b � (Cost on Back) Driveway Curb Cut Width Needed: Ft. + 6 Ft = Ft x$ _$ DATE: I (� � I$ '91v APPLICANT: : � T 1. #���� �,-�j�� _ O.CO�— � �,� Permit Fee Fire Surcharge State Surcharge SAC Charge License Surcharge Driveway Escrow Erosion Control Park Fee Sewer Main Charge Y C�YII:� I� $ �7. �ZS $_s�� $ �3. (� $ ��d.00 $ v�. PX� v $ $ $�7�• � $ � � �i �• CITY USE ONLY Fee Schedule on Reverse Side .001 of Pernut Valuation (1/lOth%) $.50/$1,000 Valua.tion � $900 per SAC Unit $5.00 (State Licensed Residential Contractors) Alt. "A" or Alt. "B" Above `� , $450.00 Conservation Plan Review x Fee Determined by Engineering Agreement Necessary [ J Not Necessary [] ' STIPULATIONS: .- BUII..DING PERNII'T FEE SCHEDULE The Chief Building Official shall, before issuing permits for the erection of any building or structure, or for any addition to any existing building or structure, or for any alterarion or repair to any existing building or structure, upon application therefore, require the payment by the applicant for such permit of fees to the amount herein below set forth and in the manner herein provided to-wit: TOTAL VALUE $1 to $500 $501 to $2,000 $2,001 to $25,000 $25,001 to $50,000 $50,001 to $100,000 $100,001 to $500,000 $500,001 to $1,000,000 $1,000, 001 and up � FEES $21 (Minimum Fee is $21 plus surcharge) $21 for first $500 plus $2.75 for each additional $100 or fraction thereof, to and including $2,000 $62.25 for first $2,0(l0 plus $12.50 for each additional $1,000 or fraction thereof, to and including $25,000 $349.75 for first $25,000 plus $9.00 for each additional $1,l?00 or fra.ction thereof, to and including $50,000 $574.75 for first $50,0� plus $6.25 for each additional $1,000 or fraction thereof, to and including $1(�,000 $887.25 for first $100,000 plus $5.00 for each additional $1;000 or fraction thereof, to and including $500,000 $2887.25 for the first $500,000 plus $4.25 for each additional $1,000 or fraction thereof, to and including $1,000,000 $5012.25 for the first $1,00O,OOU plus $2.75 for each additional $1,000 or fraction thereof DRIVEWAY DEPRESSION ESCROW (Concrete Curb Streets Only) Alternate "A" : Removal and replacement of curb and gutter only - Driveway width plus 6 feet times $13.50. Alternate "B": Removal and replacement of curb and gutter and install a 3 foot wide approach with 6 inch depth - Driveway width plus 6 feet times $15.75. VERIFICATION OF FOUNDATION Permits for construction will be issued a minimum of 24 hours from the time of application to allow for proper review of the proposed structure and of the consti�ction site. A Certif cate of Survey of the lot, showing the location of the foundation once it has it has been constructed will be required before proceeding with the framing. Sheet1 EXTERIOR ENVELOPE THERMAL TRANSMITTANCE WORKSHEET R01°l'LUND CO. INC. PRODUCT: BENTON DEVELOPMENT: CHRISTIANSON CROSSING CITY: FRIDLEY SITE ADDRESS: ��q (,Ml21 �TEVJ�GIJ �UC.[.�2.� DATE: 9-12-96 ASSEMBLY AREA (Sq Ft) U-FACTOR U-FACTOR X AREA CEILING/ROOF EXPOSED WALL INSULATED AREA 1060.97 0.043 45.62 FRAMING AREA 187.23 0.089 16.66 WINDOWS 122.00 0.500 61.00 DOORS 37.80 0.067 2.53 RIM JOIST 0.00 0.035 0.00 FIREPLACE WALL 0.00 0.072 0.00 ABOVE GRADE FOUNDATION WALL 0.00 0.087 0.00 FOUNDATION WINDOWS 0.00 0.00 FLOOR OVER UNHEATED SPACES (U = 0.04) O.W 0.00 OTHER 0.00 O.dO TOTALS E 1408.00 ' F 125.82 AVERAGE U-FACTOR: F / E = G ' G 0.089 REQUIRED U-FACTOR (from Energy Code) (U = 0.110) H 0.110 If C is greater than D, or G is greater than H, revise the design as necessary to meet the envelope criteria of the Energy Code. 1) U-Factor for skylighu and windows must be determined by the National Fenestration Rating Council Standard 100-91 or ASHRAE 1993 Handbook of Fundamentals, Chapter 27, table 5. 2) Thermal Transmittance of opaque comgonents (including integrally insulated masonry and metal stud framing) use part 7670.0450, subpart 4. Page 1� � BEC-19-1996 i2�25 SUPERIQR TRUSS P.�02� �r.. �rv �rr4+ Wd►� �j� �P+i�."7r7 �j q � � iJ611�i tl� T� ,�,� . , . . � �--°• �. q_ _�....� , � � � � �1`�6� �� ���[�� c°tn'ax' � n � +r�rr�t�r a �.Mw r�r _ . . Is�R'.M�iI��W • • •..... •� ���.n i�����i/s��.r�-s��� � � i�'��� ia�r�e �. ,-a7a;8 :f9-9D ,12�J-� . . G.9d:e �70 I � , • .. . n�, .. ..,,., '�2�9 - ��t�,_.,__.��e. „ , ,�;SD,�B �9-4� O-�a# fMi e . , a • „ �a.9D�1ti — ���,@ F'o.� i� �f�, bat�S< � : • �D+�T ! � ' ' �oa1� ° '�� � . � Q� 3 �� . f , �� , . ' �...{ ', � j � � ��k$'- p' _ �e ;� , � . 2 d��� ��.•f!}!�j �n . �� � �• P. �� 41 10 ' � 4�a �° �18� 1F�a ' . . i . . #7¢� 7�to-� �.�� ��� � ' ' 1aF � --- � � , ,� .��.,�._.�,,..� r�a� � ; � f!� t�i4�fliii '_'..,. � � � � itpq IIA'1� � � ��0 . R�piehl��lqp� f•fl! lii �{t! � fl.9�►�tJtb � 11i�t�Opf. Hi'/�. , : � ', I� � � m Mm�/11� � �!0 ' ftb - �� tliW .,. ,� _. ..-.��� .'� � s x� s� tw.e o ut�p�°� �mw ����a�w�+� . .ear c�oa�u, a�x � e�r r� • r� �! x + � x..a -� �ar�► �`�4a�r a�e,awr�4 �. sam.ed.w.� n,d;�, • � idl� 8�i 4�/f � 19Qr` i.� UJ it X � Olq� i1QOf I.ti , j �A�1�11i •t�ii4? (�1i/OrR�y9w1l1� ' � , ' �Cllp� 4•tOs t�'94l, �1 f s°��•1�a �,■!8� 6+i.-i:�a �Tr-12�,1'a� t�f�.sl6 � . � 1� ��a.�il�, s.1Q.-���f�t�v��l ��10� l..a�.7-o�-f9� � Lp1�D C1�fttb} .� � `�: �.�',�'-� t� r�d�'r �'3�--�`a': .,:� P'�' ��:- � �`►�! .'�;��a � �� ��-�i�an +'� °� �� � _ k'��}� , .� W t � .�� rl ./�I�J°; L� � �-' ° � � C , �; i�4{�,�i � O�t.�, ' . �. . . . ! ' � p�t�it' � N01� 7871 � �,� � f�, • :, • . p ,- '. , � h�rsby e�reiff► � I Eon ar.- ' e � .. waa � �ndv_�r -d ° ' ' 9 ' ,• � r��er� �('ip�M��� m� f1�a'1 l am � t� ca�aept' '.� � —'T�^ � ' � � �1 Profiat�i ' va� ` 1' d dar �,or� s �„e � btate.� a�ud �ha� � a� : . 7 �� P � � F8h B . i � -- ���.-.-..., _-�-.... -.-.��. -- - , . I : '.`� . 5 . . . :. • . ' ' pa�a��� '� •� f ��*�`' 1h�. Ne► � r � � • k' . .� . � � . ..T.�.s, � . e. . . � � . . • ' • ' , . TO'iF� P. �! , ' . — �.�� �* * * PIONE�A * eng neer * * ** uNO suR�s • av� LAND PLANNERS • LANDSCAPE ARCHIlECTS Certificate of Survey for: House Address: House Model: 2422 Enterprise Drive Mendota Helghta, MW 55120 (612) 681-1914 FAX:881-9488 825 Htghway 10 N.E. Blatne, MN 55434 (612) 783-1880 FAX:783-1883 THE .RO TTL UND COMPANY 139 C�stenson Couri � Be ton \ d� t N6�•p0 �Q < ` ✓p• / -� / Fz�j 29 ` \ ��°a °' O.C� O�4 � F � � / V / � .� e �� G. ,1 �30. � � � ��o � � d' o• \ Qi 'OOot ; ` `'� . � � GP� 1 � , �2'�'cp c �� 1 � � � � LW �0` `V�Ov � ' � IN �60 � �/ � (� i� - _� �,�9 CHRISTENS�N CO URT x eao.o Denotes Exfst[ng Eletirotlan � Dsnotes Proposed ElewtJon --�- Denotes Drainoge Flow Direction -� Denotes Drolnoge dc UtilJty Easement —o-- Denotes Monument --�- Denotea Offaet Iron Beorh�gs shown cre assumed �d /V �I'°�� � Garogo Slab Elevation: $50•42. (at doa-) NOTE: Propoasd buDding site groding is tn aceordonee rith the yrodinq pla�a a{sproved by ths dty eng�near. NOTE: Contractor muet vsrlfy aA dima�sfons & driveway Oeaign. LO T 30 . BLOCK 1 CHRIS�'ENSON CROSS.�l1TG ANOKA COUNTY. MINNESOTA We hereby certify that this survey, plon or report was prepared by me or under my dtrect superviston and that I c duly licensed Land Surveyar under the laws of the State of Mlnnesota. Dated this 16TA day of bc�ol�o/ A.D. 19� Signed: PIONEER ENGINEERING, P.A. - �_� ���� Scale: 1�= 3�� BY 1.� � v � .� Robert B. Sikich, L.S. Reg. No. 14891 or � 16190C35 Terrence E. Rothenbacher, L.S. Reg. No. 20595 irr v•� aJ1V I.J41� y"'! 1 J6.1f V�6 JiVJ ' pEC 03 '96 05�42PIM ENGII�EERING TECH SYC �ia/e�/1996 ia:98 1-5�7-8�2�s18s �urcr�iurc i rcu;� � r �- r.- �� �-ti�, F'Hlat b'L/ b1 P.1� • R'DtC�,E �a/�$ ' 7� ' • � ..r... I Tim 7yi,e ' '°_' � � • ' J �^ i � s47f1 ' R� ..` J.� —, r7 f �Ii�J�+d 13! � �tMQLLO�'Al1iS " - .. f . ��� ' ° -q-,o:e . .. �-io _, �,�-o a ��. � � � , ' Q-taa s�.�o e,z-� s-� ' � o��io.�e ! . . 4� � • , 6 i � • 9a��tz ° �� ��� �N : .���, � ; �'Ct-t �� a�, - ' �%�t- 'W f,10 � � . . �� + � : � : n a - e, '; � �,t'• �4 4x7a � . • � ; ` • . � ' ' � .' ! ' � � �i a, D4 u • ;~. '14 1� 70 � . � ' �} �m �Sn 4x4, . . , �� _ . . 7•�Q-7 �,, �8-1.� .. . , � ,I . . . i.�c.7 � 7.ia� ��+i� aq� ' T mi�o �+o ea e�, a� vae .�r�u � �'�e � �a�. �.�a �e aa a�i� ��o �n .� ��11 # ,lyialm.ar t.�l�• �C Oa1S � Qstr ��NO yrp � It�/iti � i�L 1Qi0 � � � '1�i � � �'i �04 Y Ilh �.w���w�.s�o w.�o�ra� �,. .. _ ,. e __ .. , . ::ro'��.C�NO�CNO1iAt��xfl�tl..� �� �M�e��en�'1��. • RiD:�4�:2�46�Baz • ' � 1�EYi � y� 74 4 FPP �3 •E�e�o" i41'QiOi� � a�e� ar IO� � a�e � � ' i11�as�d�Tf�lA01 i.94.MltIL��s10W t.el ' �4ws ; W,ur�.) ' 1.16fo� �st6�Y�3•i ` � � �li►eif� ; YO' i 1,��-sd�F Z 3ao, 7-h-liii, 4��•1�8. d�E+�-1� i�o-t�. �/-i�0, i�P.�I:�s dF1 3 tOR�:9�t4.�0li, f0�11■Pl�, ll•l:m7lli, I•tsstoli 1�ipee) w ! � , �-s■.�s3o. �t=�s. s-t:.� �-�d■�s, i•�a-u�, s�.��� p+� � L� � asi.�.a � oi � , � , � �w-�+--���: �"• .+ - � � , . fy" t d� ►�o b ' ar r � �t 1 e � W Yt � �°� h* �qe� , ��i � • . � �. �. �. ��9� ������� C`; i � ' I DEC-04-1996 08� 0? . 1 5�7 8'72 5185 p, � f i � !� - i� I � � ' U a> W 0 s � � � 1 � V � . � Z O i"' � z w � cri �' �- v J OW O 0 U � cs ¢ � U� Q W � � _ � � �C`3 Z � Z Z O �� d Z W U � O ¢ � p O Q �- z �O OQ U � Q � Q W � � � O Z O U W a � � Z Z m } ¢ cN+� Q � � N � `m Z•.,.d. �•=�o � � � c� T I U t�0 lL � � � W � Q g m O � � � U � F �a � � � � w 0 -a - c -� o `� .` U � l o>.�. 3 � �►- m U o� .c m � �: ti.. ..t_. _ V 1 m O � � O Y ' ' '3 .`�c � m U � �� Q c m tC � !� m i i U i O O m «� v � m D � � � � � L o t � � Q N -C � a.c� o c Q . s � � � � 3 o u, E �' y � Q o p � m'zs � m � 5 ° r �,� � -a c � � c° � � c° u� � a► o ( � � � � \ � � � � � � o � �"= ��' � m � �- � � � m � �` �` O � � � � � O o 0 0 .o � � � � � C � � � � m y r- Y � 3 � m m � 3 � ���3. O �i LL, @ � m +' � C — E � m t V > ? � � � � C C V m � � a� � o� �. a „Q = 0 fA tlf j � /l�� � I.L Q V Q 0 w � � � � 0 J � m �:� �� l�`� � 0 Z �-- � ¢ W � � -� F- � O U 0 Ll1 a � � tti Q� E �`a � g� � 0 = o p Z � � � N J � � � .� m � U � N fl � C = o ° ar U ° o U Q ►- m �� i Z o m � � Z F EI] �1 .�l v� ui �» � � 0 0 °o_ 0 0 � r r N � � � m � C at � N � � � 0 � � � N � Q 1 � c C O �' � C O U Q � m 7 � I-- � �� O C � o � .�, O � � � C Q � � Q N •j. a.. Q � O m m 3 i � -� O� O � Q T � > O m U � � Q i (� � Q � O C C! O � � � � o E � O N Ur � 0 W 0 Z N � a _ E as z m "a t�6 � m C 7 f- m m � � � � t i 3 � m � � c IlJ W LL J H � F " Wi z a � O U Z � Q � w � _ � a m 'a > 0 Q Q _ O O N v � W ltJ LL Z � H U W � � Z LIJ � Z 0 Z � ¢ U � � w > Y a F- � �w � Z w ,� � � � Y Z U � m � � W � U O J a Lt.. � � 0 t 3 � i � m A = Q/ Q � � � t6 m � Q' O N � qf � a c s o .. 73 O � c C O U '- � O cu�i O � � � � U � � � i . d 3 CHIlYINEY AND STACg VERI�ICATION The undersigaed hereby verifies that the existing chimney or stack: 1. Has l�en carefully examined Yes (�) No () 2. Is fi�ee from rust or deterioration �3. Has no foreiga objects lodged within 4. Is securely supported 5. Meets all current Code requirements for size and total BTU's conn�ted 6 Has total heating BTU's of All other BTLI's TOTAL BTU's 7. Has a liner been provided for water heater 8. Has combustion air been provided for water heater Remarks: . List ALTERATIONS Being Done: HEATING CO: Signed By: Date: Yes()No() Yes ( ) No ( ) Yes ( ) No ( ) _ Y� _� ) _No _( _ ) - Yes()No() Yes ( ) No ( ) G y � � Client: Address: City: Phone: Fax: Comment: Rottlund Homes� 2681 Long Lake Road Roseville, Minnesota 55113 638-0500 638-0501 YOUR BUILDER FOR LIFE Company: Representative: Address: City: Phone: Fax: Comrnent: e Flare Heating & Air conditioning, Inc. Randy 9303 Plymouth Ave. N. Golden Valley. Minnesota 55427 , 542-1166 542-3101 YOU CAN FEEL THE DIFFERENCE , ::::.:::::::::::<::::::<:•::::<:<:::>::»::>:>::::�:�:; :.::::.::::::.::.::: .. :<;,:.:>::::::>::: .:: : { :: ::: > : , : > <::::: : > :. > ::: :: ; :: , :.: > . ::::::::. � :::: :.:.::.:.::.;�:.�::::::::.:�.::.::.::::�.;:...::::.�.�.�.:�:.:::::::::..:..,.::;.,::.::::: :.::::.::.::.::.�:::;::..:::::�.. .: : : �. .. >. . . . : : . . : ..: :.: : . <: ::: :: :: ., :.: . ..:.: ..: ..: :.: .. . ............... .. ........... ::.: ...,.... :•..:::�w::•: . .. :?S-"'!.•::�:•;'?' ii:�^vti� i>x>�:�:::�{:'%}: • •::::::. .�:....,:: ' .. •.:. . .....................•: ::::. ... .......... . .•::4.•:::�..:::;:,.::•::......:�•,::..•r:....:�::t:�::;:;:;�:;::�;��fi�:$: ...>.,...... . :,•.,•. + ....... .::.,..,-•:..;..::.:..: :::::::::::.:::...:..•.:�::.:...:...:.:: :�::..::::: ::•:.: .:. ,. •:. :. � ., . ... ........................................•:::::::: •:.�:::::::..••..•..••.:::::•:•r•a>:,.;x:..•t2:t•:•::•:::.S•53;:�'t:'t�•�:::•r:�i�:::•�::�::::�.:::52•::: •:.xt•::::•;:•::•::::... ..... . . . ........ ..., .........,,.........:: •::. :,.t. .. :+:\.•�. i:•'.:E� .:�;: •. : : ... .•:..•::::.:.: �:...:. : : � a • .: , .: . : • :: +:.. x :. ; g ; : : : , . r +: � . . . :.. . . . .�.:?•.>•..4.;.;.; :;�. , ........:•::::::::.:�:.:::::: ::v.:[•::t:•::::.;•::. ......•::.�:::......:•:•:.�:.� w... . . .; ...:: •:.:.; ......•:r'wi:i:..`•<:•:�::�:::�.`�:`•i::'t:�:: .., .. :.:. ... .e•:::::v ..:............'• �•.ti;•.;;....:,.,:::�'•�• .....::.....:..'...... ...... ..................... ......x...:::........ . ::.......•.:.::..... .. ..:>:.� . .: •...•.�::::. ... ....... `•:::: ..:.:.. ::::::............ �:..:.':.•: •::::•'•�.�'...... . .c........:: •.:•::... •...r:::.:•:::: :•r:..�::::::::......................... . . .. .......�............... . . ....... :�. ... . .. �.. .•�.�. �..:..:::::..•:::.:::: :•:::.::•:.�:::r:.::: :• ::.::.:::..... ............ . .. . .... ............e.......o.............. ................. .......................:. •.:xr.::..v].....h\.. ..,.... ..........."'.....:.::x..: :�•:: •::: .; ..; . .............. ..................�..........................tv.•:::u; ..; ....... ,........ ..........h�.•.v:.::. ..::x.•: :•.. }..a....�.......... ........ ................�................n........... . . ... . ♦..... r. . . .. '�� ............................................. .......a...................\...........�............. ....� .......v.... ... ..................... ............. ::::.�.� .....\. .. ...n e... �.0 . ...n.. .�.v.•::x. w:::: .; ...... ..u..�....vn... :::.� :::::::::............................................. .. ........ �..........................�.....�............. �..,. �.....,.:..•.•.•.•�.•n6::�...,.,..y::::}:.•.x.C:..•:::.•}::v;...1;....:.:}::v:•}.v:.�.•.x.•:•x: Project Name: Refer�nce �ity: Daily Temperature Range: Latitude: Elevation: Winter: Summer: Minneapolis. Minnesota Medium 44 Degrees 834 Feet Outdoor Outdoor Indoor Indoor Grains � Bulb Wet Bulb flgJ� � Bulb Difference -20 N/A N/A 72 N/A 95 75 50% 75 36 Total Building Supply CFM: 659 Square feet of room area: 1,186 CFM per square foot: 0.556 Square feet per ton: 817.931 Tota( heating required with outside air: 50,755 Btuh 50.755 MBH Total sensible gain: 13,050 Btuh 76 % Total latent gain: 4,197 Btuh 24 % Total cooling required with outside air: 17,247 Btuh 1.437 Tons (based on sensible + latent) 1.450 Tons (based on 75% sensible capacity) Calculations are based on 7th edifion of ACCA Manual J. AII computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. � �omponent Area Sen. Lat. Sen. Total � Description Quan Loss Gain Gain Gain ; � 4A Window Double Pane & Storm Clear Glass Wood Frame 138 4,328 0 3,448 3,448 � SM Glass Door pouble Clear Glass Wood Frame 40 2,028 0 1,200 1,2Q,0 � 11 C Door Metal Polystyrene Core 38 1,643 0 422 422 � 121 Wall R-19 + 1/2" Asphlt Board(R-1.3) 1,192 6,032 0 1,547 1,547 ; 16H Ceiling R-38 Insulation 1,186 2,837 0 1,357 1,35�'! � 23C Siab/Warm Duct 11/2" Edqe Insulation(R-8) 176 16,192 0 0 0 � Subtotals for structure: 2,770 33,060 0 7,974 7,974 ; Active People: 4 0 920 1,200 2.120 ! Inactive People: 0 0 0 0 0 ! Appliances: 0 0 300 1,200 1.500 � Lighting:_ _ ____ � - 4 -- � � Ductwork: 0 3,786 0 0 0 i Infiltration: wnter CFM: 47.4, Summer CFM: 31.6 216 4.801 774 696 1,470 � Ventilation: Winter CFM: 90.0, Summer CFM: 90.0 0 9,108 2,203 1,980 4,183 ! Sensible Gain Total: 13.050 � Temperature Swing Multiplier: X1 00 �_Building Load Totals: 50,755 4,197 13,050 17,247 i �tal Building Supply CFM: 659 Square feet of room area: 1,186 CFM per square foot: 0.556 Square feet per ton: 817.931 Total heating required with outside air: 50,755 Btuh 50.755 MBH Total sensible gain: 13,050 Btuh 76 % Total latent gain: 4,197 Btuh 24 % Total cooling required with outside air: 17,247 Btuh 1.437 Tons (based on sensible + latent) 1.450 Tons (based on 75% sensible capacity) Calculations are based on 7th edition of ACCA Manual J. All computed results are esfimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ; � I I f� Cf� J����� HOUSE HEATING TEST RECORD ��f, ���� ; `�, a��..��` .� d ✓°�� � ' . � ,,. _;,.� ���'� -����,�� � � APT. ' FLDOR CITY �_SUBURB OCCUPANT � � � ���OWNER ' ."HEAT,LOSSl.T..�AT�-�FFiTG. INST. �^ ��� SOLD BY �-� INSTALLED BY � �� E{sctrical Wmk Br °��L � Gos Lins By � TYPE OF HEAT GA FA � HW STEAM SPACE HTR. UNIT HTR. OTHER �, GAS DEStGN CONVERSION MAKE '- MAKE OF BURNER Mod�l „�^ �' �'� �` � Modsl �`- � {f � x�-- ..; l', i .Tr%,' s�" r Gi' Ssrial G , Max. BTU RaNng — INPUT � MAKE OF FURNACE . � � • Model �, CONTROlS , ,� . � THERMOSTAT �� H ,�16PIup � Vsnt Sizs Valve KIND OF LINER SiZE � NQ�IE � Limh Drait Hood quluror �° •� � � Limit SsHin � �� Filten Sizs � umber � Fan Setting �,� � e Chimnsr Location � ,. Insids Outsids Pilor Tr� ! `l � Chimney Consirucfion Pilot Make "' �S c-� � Pilot Model � " - ��� Smoks Bomb Wiring Pilot Timing �_ �� D►aft � �` Tsct Tcy L.W. Cut Off �� ° Doar P�essurs Lig �iny Inst -''`y ¢ ,/r,� f � ; �a Prsssure � �' sresnt CO� �� Dote Tsste'd • : �- - Input CFH "'„y^ ' Per�e�nt OZ ��� Compony Teating �"�: °�� .� Stock 7emp. �,-��°`�- -- -- Pertant CO Name of Teater ~ . . ' � ,(r r - p. 6 Form 235 � � � � � �'' � 7 C !0 � � O a� � � � W > 0 Z O F- W� � W Z' m � Q � J N � 0 LL � cG O CL �C �p � � � M � � a n U co tL in U � � � W _ � N � � � � � � O m O o � � Q � _ .;:.;:.:::::::.: � ::»::><:::>:::><:: �=>::::� � ::::�::»� z ::� .; :::;:� O:::...:>:<:;:..: � o c W � Q LL 0 1-- ;>::..�;:.:::.:: tn :>::>::::>::::>::::>: Z :j:<::s::::'a:� — ::x:::,;� tt1 ::<t`�:::;:;�; m :;;�.;::t;i:Q; ��::.� O �>::.;::=:s.:. � w � � � � � X � ~ Lt.. u- :;:�;:.;;;;:-»: Q ;;;;;;;;;;;;;;>:>:; .....�, CC .;'s:?::=:<�; W :::=:�>:<::<"": Ftf:', m :�:�>::>:>::::. � � z 3 Y � � � � a:.:: :::::.:.. � <3=:�:�::�>?<�»:: � c � c � E � a r� v � m o` `o `o o` o� o 0 0 0 �!: m IJ.. LL LL LL. V � � W � � Q m O � � y D � � ' � v�- � U L J U ip _ � � � � Y - Y � = 3 m � � � i c m : � � � a � U N " U � > tD � i � 'O � � c � � � c � � o � `o •� > � 3 0 : � o� �o� � � � ; o � .�m r c m ! m � A � O � � a� i -� D� � m � �.� � � m v � � � � rn � ` , 1 � \Y1 V � 0 � � � m c 3 O � `� 1 v� cnU � �� � �, V V� \ O Z � J R W a\ F-• 0 z H � � � a � �p�, � V1 � J � z � ¢ a Q � a o. � � � � m Z c '� m W v E � Z . � � Ur m w a v� � � � � � H 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 � i: v ui r: r� i: r: o i. o 0 o ui Q v�vl��viv��f��V�i�sv� � OC Z �I I I I I I I I I� I I Z W � w � X � � Z m � � J a a� m !� � m � � m s 7 V U # [L �C * 3 ` �— Q � (� C m Z m � � �� j� � > m � � C C� C J'm ,� m N# # a 7 C Q. m tll `m O � 4�1 � �� 3 t��i p, 0 p m� Q I`- = 2¢ � li a � ►- 3 V C m �N N Y �. 3-Q m o... . E cYa a o y°' o H Z O m m U ai°[ �'n ��� C7 C7 m � � � O O O m � 0 � C r' � � °C w W = a . Q z Z (� � m Q N � U � a °C � > > � 2 W Z aQ � Q � d � � c� � W �n m � LL � Q W ~ � � � � Z � a y Q � a �o � �o Z O F W � � �. � � W �' � a 0 w � Z � F � a w W m w � p U � � S ZQ `�° � � � � H � � � � Q Q a m Z ` n. O � 0 0 � m � � a °C � ' a� � � � � �z � Q ' U # � � W � V = O � �"" o N 0 � c . o�C Q � m � � c I s rn � 0 � m v m 0 Q a Q � _ U1Y OF FRIDLEY FR[DLEY MUNIC[PAL CENTER • 6431 UNIVERSITY AVE. N.E. FR[DLEY. MN 55432 •(612) 571-3450 • FAX (612) 571-1287 October 9, 1997 Rottlund Homes 2681 Long Lake Rd Roseville, MN 55113 Re: Final Inspection at 139 Christenson Court NE, Fridley, MN Dear Sirs: A final inspection was conducted on October 9, 1997 for the above noted townhouse. We found that the construction of the building unit complies, to the best of our knowledge and belief, with all the requirements of the building codes of the City and the State of Minnesota relating thereto, and permission is hereby given for the occupancy of said unit. If you have any questions on this matter, please feel free to contact me at 572-3603. Sincerely, G�� �w� BARRY RIESCH Building Inspector RJ/mh � SUBJECT P N . - City of Fridley 2 7 2 0 6 AT THE TOP OF THE TWINS g U i L D I N G P E R M I T r ; � RECEIPT NO. � `y _ COMMUNITY DEVELOPMENT DIV. �� r � � PROTECTIVE INSPECTION SEC. 1 i � � /�"1 � CITY HALL FRIDLEV 55432 NUMBER REV DATE PAGE Of APPROVED BY �----�' �•' 612-571-3460 910-F15 8/17/98 / / JOB AODRESS 139 Christenson Ct NE 1 LEGAL �OT NO. 9LOCK TRACT OR ADDITION SEE ATTACHED DESCR. 3O 1 Christenson Crossing SHEET 2 PROPEF;TY OWNER MAIL AODRESS 21P PMONE Ke�V Bergstram 502-9550 3 CONTRACTOR MAIL ADDRESS Z�P PHONE IICENSE NO. Rnight Construction & Design 4808 Lamplighters Ln Minnetonka MN 55345 470-1649 200228 3 d ARCHITECT OR DESIGNER MAII ADDiiESS ZIP PMONE LICENSE NO. 5 ENGINEER MAtL ADDRESS ZIP PFIONE LICENSE NO 8 USE OF BUILDING Residential 7 CLASS OF WORK ❑ NEW � ADDITION ❑ ALTERATION � REPAIR O MOVE O REMOVE B DESCRIBE WORK and garage Reroof house (15 Sq) Tear-off � 8 CHANGE OF USE FROM TO STIPULATIONS Underlayment must comply with State Building Code. TYPE OF CONST. OCCUPANCY GROUP OCCUPANCV �OAO SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL. PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOIO IF WORK OF CONSTRUCTION ZONINO SQ. FT. CU. FT. AUTHORIZED IS NOT COMMENCEO WITHIN BO DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONEO FOR A PERIOD OF 120 OAYS AT ANY TIME AFTER WORK IS COMMENCEO. NO. DWLG. UNITS OFfSTqEET PARKING I HEREBY CERTIFV THAT I HAVE READ AND EXAMINEO THIS APPLICATION STALIS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SUFTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILI 8E COMPLIED WITH WHETHEF SPECIFIED MEREIN OR NOT. THE GRANTING OF A PERMIT $1251 �.63 DOES NOT PRESUME T GIVE AUT ORITY TO VIOLATE OR CANCEL THE pEFM1T fEE SAC CHARGE PROVISIONS OF A O HER STA E R LOCAL LAW REGULATING CON- S RUCT N OR TN P FORMANC F CONSTRUCTION ��F3.�0 Fire $C �1.26 PLAN CNECK FEE TOTAL FEE � � License'S $5.00 $49. 9 SIGNATUREOFCON� ACiORORAUTFI F EDAGENT ID TEI N P PEFI V IDATED T S I$ �1R PERMIT ^+ �� / l G! � � U �l '7: S� NATUREOFOWNEFl�iFOWNER8UILDER� iDATE� BLOG SP rydTE I�EW � ADDN ALTER [] Ll [l CITY OF FRIDLEY SINGLE FAMILY AND DUPLEXES R-1 AND R-2 BUILDING PERMIT APPLICATION ConstructionAddress: _ � � � Cl'�L`Si , �.�,-, Ccs��- Legal Description: Effective 1 / 1 /98 �� �� ��'�1 Owner Name & Address: p� �����A,,,� Tel. # S�Z— °t S� Contractor: � � � a, t�l� (..'o .� 5 �, � ` � � MN LICENSE # Address: e-[ Y. o`� ��� 4.. c1n � 5 � M� „� �i J..��e�►— Tel. ��� v-1 lQ `�°� LIVING AREA: GARAGE AREA: DECK AREA: Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. Length I.ength DESCRIPTION OF IlVIPROVEMENT Width Height Sq. Ft. Width Height Sq. Ft. Width Hgt/Ground Sq. Ft. OTHER: %.r2 ��i�( ��i S O � � �� Construction Type: �� Estimated Cost: $ ��^ (Fee Schedule on Back) Driveway Curb Cut Width Needed: DATE: � � c`1 � `� � APPLICANT: Permit Fee Fire Surcharge State Surcharge SAC Charge License Surcharge Driveway Escrow Erosion Control Park Fee Sewer Main Charge TOTAL STIPULATIONS: Ft. + 6 Ft = nFt x$ CITY USE ONLY _$ Tel. � $ �/,3 •G U Fee Schedule on Reverse Side $ /� Z � .001 of Permit Valuation (1/lOth%) $ � 3 $.50/$1,000 Valuation $ $1000 per SAC Unit $ sr• oV $5.00 (State Licensed Residential Contractors) $ Alt. "A" or Alt. "B" Above $ $450.00 Conservation Plan Review $ Fee Determined by Engineering $ Agreement Necessary [ J Not Necessary [] . . , .. -, BUII.DING PERMIT FEE SCHEDULE The Chief Building Official shall, before issuing permits for the erection of any building or structure, or for any addition to any existing building or structure, or for any alteration or repair to any existing building or structure, upon application therefore, require the payment by the applicant for such permit of fees to the amount herein below set forth and in the manner herein provided to-wit: TOTAL VALUE $1 to $500 $501 to $2,000 $2,001 to $25,000 $25,001 to $50,000 $50,001 to $100,000 $100,001 to $SOO,Q00 $500,001 to $1,000,000 $1,000,001 and up FEES $21 (Minimum Fee is $21 plus surcharge) $21 for first $500 plus $2.75 for each additional $100 or fraction thereof, to and including $2,000 $62.25 for first $2,000 plus $12.50 for each additional $1, 000 or fraction thereof, to and including $25,000 $349.75 for first $25,000 plus $9.00 for each additional $1,000 or fraction thereof, to and including $50,000 $57�.75 for first $50,000 plus $6.25 for each additional $1,000 or fraction thereof, to and including $100,000 $887.25 for first $100,000 plus $5.00 for each additional $1,000 or fraction thereof, to and including $500,000 $2887.25 for the first $500,000 plus $4.25 for each additional $1,000 or fraction thereof, to and including $1,000,000 $5012.25 for the first $1,000,000 plus $2.75 for each additional $1,000 or fraction thereof DRIVEWAY DEPRESSION ESCROW (Concrete Curb Streets Only) Alternate "A" : Removal and replacement of curb and gutter only - Driveway width plus 6 feet times $13.50. Altemate "B" : Removal and replacement of curb and gutter and install a 3 foot wide approach with 6 inch depth - Driveway width plus 6 feet times $15.75. VERIFICATION OF FOUNDATION Permits for construction will be issued a minimum of 24 hours from the time of application to allow for proper review of the proposed structure and of the construction site. A Certificate of Survey of the lot, showing the location of the foundation once 'it has it has been constructed will be required before proceeding with the framing.