Loading...
P - 48655Building Inspections 763-572-3604 763-502-4977 FAX MECHANICAL RESIDENTIAL APPLICATION CITY OF FRIDLEY EFFECTIVE 1-1-2012 Permit No. Received Date�;,,�: �U DATE 3' Z.�Q —� Z YOUR E-MAIL ADDRESS����� D,h S� [.(� �i�-�..j �}ew'$ , SITE ADDRESS ��4 I S, r' �' � �,�`C► Cji �'(�A N�L.. THIS APPLICANT IS: ❑ OWNER `�CONTRACTOR PROPERTY OWNER/ TENANT CONTRACTOR SUBMIT A COPY OF YOURSTATE LICENSE WiTH APPLICATION NAME:� � �(_ �� �,,,^}Y1hS O h ADDRESS:_� � ( S . �j � � M OY`` C,,IY. � �. CITY �` �`,2,��STATE�(�( ZIP�C�, '� PHONE: �Q.I Z` S S�-1- L? G 8 9 COMPANYNAME:�I���/-�- Cp•-L7�e1'.S rJ�� �L.S,7�-� �„j �n�T� lr1 L.• CONTACT PERSON: �( STATE LICENSE # EXP DATE ADDRESS: �l`�"IXI �-) � Si' N� CITYk}QNc7�et.✓ STATEi�I� ZIP �J�3� � PHONE 1 l.Q 3' ZdD-{+Pt-I�I I F� �-� � 3- y a sr-� c.e � Y PERMIT TYPE � SINGLE FAMILY ❑ TWO FAMILY TYPE OF WORK: � ��'�' �REPLACEMENT �TOWNHOUSE ❑ ALTERATION/REMODEL DETAILED DESCRIPTION OF WORK (�p,j-}-a,(,� a n�� .�}=�y Lp hG( ���p�y FEES ARE BASED ON $10.00 PER FIXTURE, EXCEPT WHERE NOTED. FIXTURES: (INDICATE TOTAL NUMBER OF EACH BELOV� PROVIDE HEAT LOSS CALC'S PER MANUAL J 2006 ASHRAE HANDBOOK. Equipment Installed MFG: C��� G h MODEL: � S �(13171K (� SIZEBT[J �_ � A/C $25.00 AIR TO AIR EXCHANGEER $15 BOILER $35.00 CHIMNEY LINER $10.00 DUCT WORK $]0.00 MFG: MODEL: MFG: MODEL: FIREPLACE (GAS) $15.00 FIREPLACE (WOOD) $35.00 FURNACE $35.00 GAS DRYER $10.00 GAS PIPING $10.00 SIZEBTU SIZEBTU GAS RANGE/OVEN $10.00 NEW GAS GRILL $10.00 GAS LTNIT HTR $10.00 POOL HEATER $35.00 VENTILATOR $15.00 THIS IS AN APPLICATION FOR A PERMIT-NOT VALID UNTIL PROCESSED I hereby apply for a building permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Fridley and with the Minnesota Construction Codes; that I understand this is not a permit but only an application for a permit and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of all work wh�i requires review and approval of plans. SIGNATURE OF APPLICANT APPROVALINSPECTORS NAME��� `t��11(�l'-}%1p11j^(.b'd DATE 3 Z�.¢ "L �2.. TIATF � � � I1 City of Fridley `�uilding Inspections Department 6431 University Avenue NE, Fridley, MN 55432 763-572-3604 FAX: 763-502-4977 �� Comfort Matters Heating and Cooling, Inc 10981 4th St NE - Hanover, MN 55341 763-493-2665 - corey@comfortmatters.com Sales Consultant: David Simon Job#: Johnson Date: 03/27/2012 Rick Johnson 1041 S Fillmore Circle NE Fridley, MN 55342 System 1 (Average Load Procedure) Design Conditions Location: Minneapolis/St Paul AP, Minnesota Elevation: 834 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 44° N Design Grains: 24 Summer: 88 75 Heated Area 1330 Sq.Ft. Winter: -11 70 Cooled Area 1330 Sq.Ft. Heat/Loss Summary (July Heat Load Calculations� Gross Sensible Latent Area Loss Gain Gain Walls 657 3892 1035 0 Windows 108 4986 4431 0 Doors 21 476 153 0 Ceilings 1330 4094 2527 0 Skylights 0 0 0 0 Floors 73 8030 0 0 Room Internal Loads 0 2860 400 Blower Load 1707 0 Hot Water Piping Load 0 0 Winter Humidification Load 0 0 0 Infiltration 11850 839 957 Ventilation 0 0 0 Duct Loss/Gain EHLF=O ESGF=O 0 0 0 AED Excursion n/a 1715 n/a Subtotal 33328 15267 1357 Total Heating 33328 Btuh Total Cooling 16624 Btuh Approved ACCA MJ8 Calculations 10 kw of electric heat 66 Linear ft. of Hydronic Baseboard *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed calculations are estimates based on building use, weather data, and inputted values such as R-Values, window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as This application has g/ass areas that produce large cooling /oads for part of the day. Variab/e air volume devices are required to overcome large spikes in so/ar load for one or more rooms. lnstall a zoned system or provide zone contro/ (individual, motorized, thermostatically controlled dampers) for problem rooms. Sing/e speed equipment may not be suitable for this application. Adtek AccuLoad Report Version 3.0.7 Page 1