P - 80966B�i� �ing
Inspections
763-572-3604
763-502-4977 FAX
MECHANICAL
RESIDENTIAL APPLICATION
CITY OF FRIDLEY
EFFECTIVE 1-1-2012
Permit No.:
Received
�� f�e��
DATE 3— 2c p�� 2- YOUR E-MAIL ADDRESS�� L'"� r{��11.i'1SL0I� C[ZA�j ✓'�"I..i CF.� I u ��
SITE ADDRESS �� � S S, � I 1 M �Y`C. C�1 V"C.� � N�
THIS APPLICANT IS: ❑ OWNER �ONTRACTOR
PROPERTY
OWNER/
TENANT
CONTRACTOR
SUBMIT A COPY OF
YOURSTATE
LICENSE WITH
APPLICATION
NAME:�'`/� � 1f-�-� C.lX7 C�1(1
ADDRESS: �� 5 S. F� I I MOYY�[� GI 1�. n,�CITY r^y-j u( p�,�_ STATE (�ZIP ��{ 3
PHONE: � �.Q 3—��7 2--732 3
COMPANY NAME: '
CONTACT PERSON: ��1(Y�,1 �(..t ���-{�/l:Q_.!'1SC,(���
STATE LICENSE # � EXP DATE
ADDRESS:C��'?� �"� S`�' l�i � CITY �-{-QY1t7V'�V STATE�� ZIP r-`�S3y �
PHONE-I l.P� -�Z� � (�� �_---- FAX `1 �,Q �=y ��] �I_�S - _. __
PERMIT TYPE � SINGLE FAMILY ❑ TWO FAMILY
TYPE OF WORK: � NEW � REPLACEMENT
�1 TOWNHOUSE
❑ ALTERATION/REMODEL
DETAILED DESCRIPTION OF WORK � Y1�S�Yi.[� 0. h�r,�� lA�\V C�►�c� I�"1 hp,v_
FEES ARE BASED ON $10.00 PER FIXTURE, EXCEPT WHERE NOTED. FIXTURES: (INDICATE TOTAL NUMBER OF EACH BELOVI�
PROVIDE HEAT LOSS CALC'S PER MANUAL J�2'0"06 ASHRAE HANDBOOK. 2
Equipment Installed MFG:��U(vIQ,Y� MODEL: u�s�( I3� I�I 3 SIZEBTU _J�
�A/C $25.00
AIR TO AIR EXCHANGEER $15
BOILER $35.00
CHIMNEY LINER $10.00
DUCT WORK $]0.00
MFG:
MODEL:
MFG: MODEL:
FIREPLACE (GAS) $15.00
FIREPLACE (WOOD) $35.00
FURNACE $35.00
GAS DRYER $10.00
GAS PIPING $]0.00
SIZEBTU
SIZEBTU
GAS RANGE/OVEN $10.00
NEW GAS GRILL $10.00
GAS UNIT HTR $10.00
POOL HEATER $35.00
VENTILATOR $15.00
THIS IS AN APPLICATION FOR A PERMIT-NOT VALID UNTIL PROCESSED
I hereby apply for a building permit and I acknowledge that the information above is complete and accurate; that the work will be in
conformance with the ardinances and codes of the City of Fridley and with the Minnesota Construction Codes; that I understand this is
not a permit but only an application for `a permit and work is not to start without a permit; that the work will be in accordance with the
approved plan in the case o,f all work whid� re�es review and approval of plans.
� l- \
SIGNATURE OF
APPROVALINSPECTORSSIGNA
PRINTNAMEC(�lilj�t��t�1(i'�nP.Vl�iLp�G DATE 3"'2�D-IZ
,..'J � _. l � /�
City of Fridley
�uildi�g Inspections Department
6431 University Avenue NE, Fridley, MN 55432
763-572-3604 FAX: 763-502-4977
, Cor�fort Matters Heating and Cooling, Inc
' 10981 4th St NE - Hanover, MN 55341
763-493-2665 - corey@comfortmatters.com
Sales Consultant: David Simon
Job#: Aldrich
Date: 03/27/2012
Ann Aldrich
1045 S Fillmore Circle NE
Fridley, MN 55342
System I (Average Load Procedure)
Design Conditions
Location: Minneapolis/St Paul AP, Minnesota Elevation: 834 ft Daily Range: Medium
Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 44° N Design Grains: 24
Summer: 88 75 Heated Area 1610 Sq.Ft.
Winter: -11 70 Cooled Area 1610 Sq.Ft.
HeatlLoss Summary (July Heat Load Calculations)
Gross Sensible Latent
Area �oss Gain Gain
Walls 414 2538 756 0
Windows 70 3232 4166 0
Doors
Ceilings
Skylights
Floors
Room Internal Loads
Blower Load
Hot Water Piping Load
Winter Humidification Load
Infiltration
21 612 197
1330 4094 2527
0 0 0
73 8030 0
0 2860
1707
0
0 0
12290 880
0
0
0
0
400
0
0
0
1004
Ventilation 0 0 0
Duct Loss/Gain EHLF=O ESGF=O 0 0 0
AED Excursion n/a 2216 n/a
Subtotal 30796 15309 1404
Total Heating 30796 Btuh
Total Cooling 16713 ` Btuh
�
Approved ACCA
MJ8 Calculations
10 kw of electric heat
61 Linear ft. of Hydronic Baseboard
*Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA. All computed
calculations are estimates based on building use, weather data, and inputted values such as R-Values,
window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as
This application has g/ass areas that produce large cooling /oads for part af the day. Variab/e air vo/ume
devices are required to overcome large spikes in solar load for one or more rooms. Install a zoned system or
provide zone control (individual, motorized, thermostatically controlled dampers) for problem rooms. Sing/e
speed equipment may not be suitable for this application.
Adtek AccuLoad Report Version 3.0.7 Page 1