HomeMy WebLinkAbout2013-089 Plunkettes 40 52nd Way NE CITY OF FRIDLEY
FIRE DEPARTMENT ��r+ " " � � �
6431 University Avenue NE ���;Q1'�„ �' , � � � �"� ��e�=
Fridley, Minnesota 55432 �.�����°�� � �'�` S � � ��k�° �,'�'"
r� 4�„
763 572-3621 or 763 572-3612 ` � `` "� '" �� ' k � �` � �A � ;`�
( ) ( ) �' ece�ip �ofa'���� p�erm►�;No��.���`�� 3 9 F��� � ` �
��.� �#q vx�w� 1�1��P r�� u. ! a� I�'i ��"�'s I �`v.,.. r �}E �°a x� v�' r�#' @ 'L g'
(fax) (763) 572-8825 � �k�Q04502453/97 25�;�'` � " E�'��" �'�����k��'}���; ���n'w� '�'° ;-
�, Rs� .�"��m�F„ ��3 ��xt� s u� � '� ��."
"�t1��5��k'E ''�,a. �i .� ��....a'A�'�ro i .� � ��� �u.��,�� i ��y � r ,�
JOB ADDRESS: 40 52"d Way NE, Fridley MN
NAME OF BUSINESS: Plunkettes
DESCR/PT/ON OF PERM/T(SJ: Sprinkler System
ERC/D# (Hazardous Materials)lf applicable: COST VALUAT/ON OF JOB(Required): $ 4,000.00
(A copy of the contract must accompany the application for permit)
. ", PERM/T FEE: $97.25 DATE WORK SCHEDULED:
OWNER: OWNER ADDRESS:
OWNER PHONE:
CONTRACTOR: Viking Auto Sprinkler Co
ADDRESS: 301 York Ave
State Lic#: C0005 St Pau/MN 55130
PHONE# 651.558.3237
This permit is granted subject to compliance with applicable codes, ordinances and regulations governing the
above-described operations. This permit is non-assignable and shall be maintained in the place of business or
site for which this permit is granted. It shall be the responsibility of the permittee to contact the Fire Marshal's
Office for final inspection of the permitted activity.
G� FO
DA7'E• R d�a 1—('�
BY•
10I08I2013 �����FY RtaE��` . �f� �„_
� �
Date Authoriz by: Matthew Fie , _ c or
Contractor's Materiat and Test Certificate for flboveground piping
PROCEDURE
Upon completion of work inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative.
All defects shall be corrected and system left in service before contractor's personnei finally leave the job.
A certificate shall be filled out and signed by both representatives.Copies shall be prepared for approving authorities,owners and contractor.
It is understood the owner's representative's signature in no way prejudices any ciaim against contractor for faufty materiai,poor workmansfiip,
or failure to comply with approving authority's requirements or Iocal ordinances.
PROPERTY NAME: Plunketts X
PROPERTY ADDRESS: 40 NE 52nd Way
ACCEPTED BY APPROVING AUTHORITIES(NAMES):
Fridtey
ADDRESS:
PLANS INSTALLATION CONFORMS TO ACCEPTEO PLANS ✓ YES N�J
EQUIPMENT USED IS APPROVED Q YES ❑ NO
IF NO,EXPLAIN DEVIATIONS:
HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATIOI ✓ YES NO
OF CONTROL VAWES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT?
IF NO,EXPLAIN
INSTRUCTIONS
HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: � YES NO
1. SYSTEM COMPONENTS INSTRUCTIONS „n�, YES ❑ NO
2. CARE AND MAINTENANCE INSTRUCTIONS �YES ❑ NO
3. NFPA 25 Q YES � NO
LOCATION SUPPLIES BUILDINGS:
OF SYSTEM
MAKE MODEL YEAR OF ORIFICE QUANTITY TEMPERATURE
MANUFACTURE SIZE RATING
Reliable FIFR P 2012 1/2" 25 155•F
SPRINKLERS
PIPE AND Type of Pipe: CONFORMS TO NFPA 13 ,Dyna Flow,XI pipe,Sched-10
FITTINGS Type of Fitting: CONFORMS TO NFPA 13 ,Anvil steel fittings
ALARM DEVICE MAXIMUM TIME TO OPERATE
ALARM VALVE THROUGH TEST CONNECTION
OR FLOW NPE MAKE MODEL MIN SEC
I N DICATOR VAN E POTTER
DRY VALVE Q.O.D.
MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO.
XXX )OCX
TIME TO TRIP TIME WATER ALARM
THROUGH TEST WATER AIR TRIP POINT REACHED OPERATED
CONNECTION' PRESSURE PRESSURE AIR PRESSURE TEST OUTLET' PROPERLY
MIN SEC PSI PSI PSI MIN SEC YES NO
ORY PIPE without
OPERATING Q.O.D.
TEST Wdh
Q.O.D.
IF NO,EXPLAIN
�MEASURED FROM TIME INSPECTOR'S TEST CONNECTION IS FULLY OPENED
OPERATION
�PNEUMATIC �ELECTRIC �HYDRAULIC
PIPING SUPERVISED YES NO DETECTING MEDIA SUPERVISED YES NO
DOES VALVE OPERATE FROMTHEIVIANOALTRIP AND/�RRENIZ3TE CONTROL STATIONS YES NO
DELUGE AND IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO,EXPLAIN
PREACTIOfV
VALVES YES NO
DOES EACN CIFcCUIT OPEF<ATE DOES EACH CIRCUIT MAXIMUM TIME TO
MAKE MODEL SUPERVISION LOSS ALARM? OPERATE VALVE RELEASE? OPERATE RELEASE
YES NO YES NO MIN. SEC.
PRESSURE LOCATION MAKE& SETTING STATIC PRESSURE RESIDUAL PRESSURE FLOW RATE
REDUCING &FLOOR MODEL (FLOWING)
VALVE TEST IN�ET(PSI) OUTLET(PSI) INLET(PSI) OUTLET(PSI) FLOW(GPM)
TEST : y ros ic es s s a e ma e a no ess an psi . ars or o ours or pai . ars a ove
DESCRIPTION static pressure in excess of 150 psi(10.2 bars)for two hours.Differential dry-pipe valve clappers shall be left open during
test to prevent damage.All abovegroung piping leakage shall be stopped.
PNEUMATIC:Establish 40 psi(2.7 bars)air pressure and measure drop which shall not exceed 1'r4 psi(.01 bars)in 24 hours.
Test pressure tanks at normal water level and air pressure and measure air pressure drop which shail not exceed
134 psi(0.1 bars)in 24 hours.
ALL PIPING HYDROSTATICALLY TESTED AT 200 PS!LBARS)FOR 2 HRS. IF NO,STATE REASON
DRY PIPWG PNEUMATICALLY TESTED ❑YES �NO /3d /S 5 O O r!£/[
EQUIPMENTOPERATESPF20PERLY QYES CJNO wvRl���-G- /'2tS�kR £
DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDT7IVES i41VD�URROSIVE CHEMICALS,SODIUM SILICATE OR
DERIVATIVES OF SODIUM SILICATE,BRINE,OF.!)TN�RS.PRRSL�6LFJ.'N�AM.�l,c1NERE NOT USED FOR TESTING SYSTEMS
OR STOPPING LEAKS? � YES NO
TESTS DRAIN READING OF GAGE LOCATED NE?�n'04A i cR. RESIDUAL PRESSURE WITH VALVE IN TEST
TEST SUPPLY TEST CONNECTION: PSI (_BARS) CONNECTION OPEN WIDE PSI
UNDERGROUND MAINS AND LEAD IN CONECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE
TO SPRINKLER PIPING.
VERIFIED BY COPY OF THE U FORM NO.856 �YES �NO OTHER EXPLAIN
FLUSHED BY INSTALLER OF UNDER-
GROUND SPRINKLER PIPING �/ YES NO
IF POWDER-DRIVEN FASTENERS ARE USED IN CONCF�EiE,tiiAS FcEP- IF NO,EXPLAIN
RESENTATIVE SAMPLE TESTING BEEN SATISFACTORILY COMPLETEDT ./ YES NO
BLANK TESTING NUMBER USED LOCATIONS NUiVIBER REMOVED
GASKETS 0
WELDED PIPING ✓ YES NO
IF YES...
DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY
WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3? �YES Q NO
DO YOU CERITIFY THAT THE WELDING WAS PREFORMED BY WELDERS QUALIFIED IN
WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS D10.9,LEVEL AR-3? Q YES �NO
DO YOU CERITIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A
DOCUMENTED QUALITY CONTROL PROCEDURE TO ENSURE THAT AL�DISCS ARE
RETRIEVED.THAT OPENINGS IN PIPING ARE SMOOTH.THAT SLAG AND OTHER
WELDING RESIDUE ARE REMOVED,AND THAT THE INTERNAL DIAMETERS OF
PIPING ARE NOT PENETRATED? ✓ YES NO
CUTOUTS DO YOU CERITIFY THE YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL
DISCS CUTOUTS(DISCS)ARE RETRIEVED? J YES NO
HYDRAULIC �;AM�PIATE PROVIDED IF NQ,EX?LAIl�:
DATA
NAMEPLATE � YES NO
DATE LEFT 1N SERVYCE'VS�'ri?+�L GOhiTR01.VHtVES OPEN:
REMARKS
NAME OF SPRINKLER CONTRACTOR
VIKtNG AUTOMATIC SPRINKLER COMPANY
TESTS TNESSED B
SIGNATURES FOR PRO ERTY O NER SIGNE TIT�,y�. DATE
� � �iitc��rll�-/ L'ct -�/—/3
FOR I KL R CO TRA�J O IGNED) TITLE DATE
L S� /.� C F/Z �7fElZ �v-/�-/�
ADDITIONAL EXPLA TIO ND NOTES
CITY OF FRIDLEY
FIRE DEPARTMENT
FIRE MARSHAL'S OFFICE
DEPARTMENT OF FIRE PREVENTION
Fire Sprinkler Plan Review Comments
Date: October 08, 2013
Address: Plunkettes
40 52nd Way
Fridley, MN 55432
Project: Relocate and change sprinkler heads for remodel.
Contractor: Viking Sprinkler Company
301 York Ave.
St Paul, MN 55130
651-558-3237
The conditions contained herein shall be considered as requirements for the project. The
City expects that ALL work performed will meet the requirements of 2010 NFPA 13.
1) At the START of the job
- Call 763-572-3621 and speak with / leave a message for Matthew Field that the job is
starting
- Include the Permit number and address of job site in your message
- Leave the estimated time that the work will be completed
2) Call for a rough-in inspection prior to installing ceilings
3) At the END of the job
- Call 763-572-3621 to set up a fmal inspecrion
Reviewed by Matthew Field, Fire Marshal
<
4
Bulletin 014 Rev.J
�
�w. � Model F1 FR Series �.
0
Quick Response �
�
Standard Spray �
�
Model F1 FR56 Sprinkler Types
Standard Upright ��~ � •r�. �,�
°"" �;;;`�
Standard Pendent � � �
Conventional `` `
Vertical Sidewall
Horizontal Sidewall ' �
��� ���
Modei F1 FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP Upright Pendent Conventional
Horizontal Sidewall ���
Model Fi FR56 Concealed Sprinkler Types y� . � :,,
Standard Pendent
Model F1 FR42, F1 FRXLH & Fi FR28 Sprinkfer ��-� �"�.�
Types Vertical Sidewall Horizontal Sidewall Recessed
Standard Upright PendenVF1/F2
Standard Pendent �
�,� ``' � �:' ,,,,.- �
Model F1 FR42, F1 FRXLH & F1 FR28 Recessed �., �: ;• a �....,
Sprinkler Types > �� 4�
� ;�
Standard Pendent � ��'
#:
Model F1 FR56LL&F1 FR42LL Low L�d Sprinkler � . �;' -,+ ..',°'. '`� �
Ty�* Recessed Concealed Recessed
Standard Pendent Horizontal Sidewall Pendent Pendent/FP
Less than 0.25% Lead Content
Listing & Approvals ��` �,�� �
��, �� y`'
1. Underwriters Laboratories Inc. and Certified for � �,
Canada(cULus). �' °; � `;� `
2. Factory Mutual Approvals (FM) -
3. Loss Prevention Council (LPCB, UK) XLH Upright XLH Pendent XLH Recessed
4. VdS Schadenverhutung GmbH PendentFl/F2
I 5. *NSF Certified to NSF/ANSi Standard 61 Annex G to apply water to a fire much faster than
UL Listing Category standard sprinklers of the same tem-
Sprinklers,Automatic&Open(VNIV) perature rating. r
�uick Response Sprinkler The glass bulb consists of an accu- F `'
rately controlled amount of special fluid �
Product Description hermetically sealed inside a precisely
f Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, manufactured glasscapsule.This glass XLH Recessed
FIFRXLH & F1FR28 Series Sprinklers are quick response bulb is specially constructed to provide PendentFP
sprinklers which combine the durabiliry of a standard sprin- fast thermal response.
kler with the attractive low profile of a decorative sprinkler. At normal temperatures, the glass buib contains the fluid
The Models F1 FR56, F1 FR56LL, F1 FR42, F1 FR42LL, in both the liquid and vapor phases. The vapor phase can
FIFRXLH & F1FR28 Series Recessed automatic sprinklers be seen as a small bubble. As heat is applied, the liquid
utilize a 3.0 mm frangible glass bulb. These sprinkiers have expands,forcing the bubble smal4er and smaller as the liq-
demonstrated response times in laboratory tests which are uid pressure increases. Continued heating forces the liquid
five to ten times faster than standard response sprinklers. to push out against the bulb, causing the glass to shatter,
IThis quick response enables the Model F1 FR56, F1 FR56LL, opening the waterway and allowing the deflector to distrib-
F1 FR42, F1 FR42LL, F1 FRXLH & F1 FR28 Series sprinklers ute the discharging water.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Application
Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick
response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
*Pin tle
(XL H On ly�
Deflector
Load Screw
Washer Bulb
Fram e Cup
014FG06A
Model F1FR42,FIFRXLH Upright
Technical data:
Models Discharge Coefficient Response Thread yyorking Working Temperature Ftnish
Size pressure Pressure Rating
F1 FR56 K 5.6
**Fi FR56LL�'�
F1FR42 Quick 1�2��NPT See See
*'F1FR42LL�'� K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature ��Finish Table"
Fi FRXLH Ratings"Table.
F1 FR28 K 2.8
�'�Low l.ead Sprinklers available only with Temperature Rating 200°F/93°C
Material Data:
Frame Deflector Load Screw *Pintle Cup Washer Bulb
DZR Brass CDA Alloy 260, CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360
CDA Alloy 220
QM Brass or or or coated with PTFE Adhesive Glass
I *'Low Lead Brass CDA AlIoy510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
2.
Model Fi FR56, Upright, Pendent & Conventional Sprinklers
Model F1 FR42, F1 FRXLH & F1 FR28 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Instailation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler ldentification Number
(SIN)
Orifice
Size US Metric Height Organization Upright Pendent
Standard-Upright(SSU)and Pendent Deflectors Marked to Indicate Position
1/2"(15mm)�'� 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,2,3,4 RA1425�'x2x3� RA1414�'xzx3> I
7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) 1 RA1423�'� RA1413
3/8"(10mm) 1/2"NPT(R1/2) 2.8 40 2.25"(57mm) 1 RA1421�'> RA1411
Conventional-Install in Upright or Pendent Posltion
15mm�'� 1/2"NPT(R1/2) 5.6 80 57mm 3,4 RA1475�3�
�'�cULus listed corrosion resistant(Polyester coated)sprinkler.
�z>Polyester coated FM approved sprinkler.
�3>Polyester coated LPCB&VdS approved sprinkler RA1425,RA1414&RA1475.
�
Upright Pendent Conventional
Modef F1 FR56LL & F1 FR42LL Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler ldentification Number
(S1N)
Orifice
Size US Metrlc Height Organization Pendent
Standard-Pendent Deflectors Marked to Indicate Position
1(2"(15mm)�'� 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) 1,5 RA1414
7/16"(11mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) 1,5 RA1413
�'>cULus listed corrosion resistant(Polyester coated)sprinkler.
3.
Model F1 FR56, F1 FR42, Fi FRXLH & F1 FR28 Quick Response Recessed Pendent Sprinkler�'�
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Sprinkler ldentification Number
Orifice Size US Metric Height (SIN)
1!2"(15mm) 1/2"NPT(RYz) 5.6 80 2.25"(57mm) RA1414
7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) RA1413
3/8"(10mm) 1/2"NPT(R1/2) 2.8 40 2.25"(57mm) RA1411
�'>Refer to escutcheon data table for approvals&dimensions
Model Fi FR56LL & F1 FR42LL Quick Response Recessed Pendent Sprinkler�'>
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Sprinkler ldentification Number
Orifice Size US Metric Height (SIN)
1/2"(15mm) 1/2"NPT(R'/z) 5.6 80 2.25"(57mm) RA1414
7/16"(10mm) 1/2"NPT(R1/2) 4.2 60 2.25"(57mm) RA1413
�'�Refer to escutcheon data table for approvals&dimensions
,,.,-�E�.
-- n..,.,_i -- r— ._1
��v�e�m L" ' _��
n..�mi ___'_"
I I"X I/1'REOUCER
__I___
r � ___ __
�__v_� �5/B'OiA.[66.JmmJ
r r___I��e., OiE iN CENrv� �
I
___�J i'x r%'FCOUCEF \ /
� I 2 5/1ti"Ob1.(591mm] � �
�N��� 1\ / l[SCA�ia[OxrrrvL a�u[rvsOx LUP
f-\ � /-I L. J
� � j o urc cciuHC rncc or rrr�x+c
A/M4X�MUU NECE55�17�5.�mm/ �
rzccess=/e79.�T/ — IO fACE Of CE2M/G
_�t/JJ��� �/ ,`1� 0/M£NSIOn'
��/.7r�9rmm1 ✓J J > V A��ss_�/.rrvmm) ]�\� A/NAN/MU4 NECE55�]-II2TJ9mm)
a0JU5IUENI � I u�HiuUl//1ECE55 J B 9.Smm AI NM/MUM RECE55-I'(pS.Imm)
° /T ) ��V�
!/0 u5/MENI,� �—J aI, ~RECE55
rscu 6 /S7T1I' i
��1 A�NNiM��/fE�'ESS-I-/6'[ . ,] A��NINUM RELE55�9/I6711.Jmm]
t=zn^' Fz Es�.,, '"'" v,'�soemmJ TI Al MIMMUN RfCE55� �T�S.�mm/
u�a�eccFSSS.i-r/e7aacmm/ nausr,u[Nr �
— -- r Ma�.uw. .,_s/e7<r..v�m� �r/�"ou. �
(as.cm.�)
'iri�mi
I Model F1FR56,F1FR56LL,F1FR42,F1FR42LL,F1FRX�H& Model F1FR56,F1FR56LL,F1FR42,F1FR42LL,FIFRXLH& I
F1FR28 F1 or F2 F1FR28 FP
Model Fi FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installatlon Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal K Factor Sprinkler
Nominal Thread Size Sprinkler Approval Identification
Orifice US Metric Height Organizatlons Numbers SIN
'/z" 15mm Yz"NPT R1/2 5.6 8.0 2.25" 57mm 1,2,3,4 RA1485�2�
15mm '/z"NPT R1/2 5.6 8.0 2.25" 57mm 4�'�
�'��PC Approval is for pendent position only.
�z�cULus Listed corrosion resistant(Polyester coated)sprinkler.
Sprinkler Type Deflector to Ceiling Distance
Min.-Max.
U ri ht 4" 102mm -12" 305mm
Pendent 4" 102mm -12" 305mm
Vertical Sidewall
4.
Model F1 FR56 Quick Response Horizontal Sidewall Sprinkler
Deflector:HSW
Installation Wrench:Model D Sprinkler Wrench
Installation Data: Horizontal Sidewall
Nominal K Factor Sprinkler Approval Organizations
Height and Type of Approval Sprinkler
Nominal Orifice Thread Size Identification
Ordinary Numbers SIN
US Metric Light Hazard Hazard � �
Yz"(15mm) YZ"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435�'��2� I
I �'�cULus Listed corrosion resistant(Polyester coated)sprinkler.
�2�Polyester coated FM approved sprinkler.
FACE OF F/T7lNG
TO FACE OF CE/LING DIMENS/ON
F7 ESCUTCHEON
AT MAX/MUM RECE55= 1(25.4mmJ
A7 M/N/MUM RECE55= 3/8(9.5mm] Fi S�TCHEON
FZ ESCUTCH£ON AT MAXIMUM REC£55 � 1-3/8r34.9mmJ
1"
AT MAX/MUM RECESS = J/4(l9mm] A7 MINIMUM RECESS= 2-i/16'r52.4mm]
AT MIN/MbM RECESS = 3/8(9.SmmJ F7 ESCUiCHEON
AT MAXIMUM RECE55 = 1-5/8(41.JmmJ
'Y�I II� 2 I/4"HOLE DIA. ��8. Ar MIN/MUM RECfSS a 2-I/16r57.4mm�
(57.2mmJ (J.2mmJ
- . 1"X i/2°REOUCER r
�� ^1 ��)
;�"r ; a'-tz°
Horizontal Sidewall i 15/16°DIA. 1 ai (I01.6mm-J04.Bmm]
(49.2mmJ iw�--- —'-- 2 27/32"DIA. C£ILING 70
I � (72.2mmJ DEFL£CTOR
1 � iu� i _ � �
1 �_r__L_.
TURN COLLAR UNTIL \\,'
�\
71CHT AG4INST SPRINKLER \�; Fi ESCUTCHEON
WRENCH BO55. �
� 3/4(19mm)ADJUSTMENi
F2 ESCU7CNEON
I/?[12.7mmJ AOJUSTMENT
RFCFSSFp HSW W�F1 OR F2 ESCUTCHEON ��
(if FM APPROV£D FOR 4"- 6'(101.6MM - 152.4MMJ C£lLINC TO DEFCEC70R WITH F2 ONLY.
Note: For Recessed HSW Sprinklers use installation wrench GFR2.
cULus permits use with F1, F2 or FP escutcheons for"Light Hazard"
only.While FM limits use for the same hazard with the F2 escutcheon
only.
Model F1 FR56 Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
"K"Factor Temp. Rating Max. Sprinkler
Nominal Thread Model Ambient Bulb Approvals Identification
Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN)
Yz"(15mm) 5.6 80 'h"NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1 RA1414
'/z"(15mm) 5.6 80 '/z"NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 1,4�'� RA1414
Yz"(15mm) 5.6 80 '/2"NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C Yellow 1 RA1414
Yz"(15mm) 5.6 80 '/2"NPT F1FR 200°F/93°C 165°F/74°C 150°F/65°C Green 1 RA1414
�'>For VdS only=155°F/68°C Norbulb and 1/2"[12,7mm]adjustment.
Model F1 FR56LL Quick Response Concealed Pendent Sprinklers
Installation Wrench: Model RC1 Sprinkler Wrench
Technical Data:
"K"Factor Temp. Rating Max. Sprinkler
Nominal Thread Model Ambient Bulb Approvals Identification (
Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN)
'/z"(15mm) 5.6 SO Yz"NPT F1FR56LL 200°F/93°C 165°F/74°C 150°F/65°C Green 1,5 RA1414
5.
I --�_—
�'x t/z"REOUr,iNC ,°x �/z° REOUCrnc\
TFE OR ,1_BON rFE OR E�BOW
�..._._._. _____._' .�
- �� ---.1 � �(- - �__ . .___ � -
� --_ -- ,--- f ---_�_ I �_-_�_
} _ __
� .J �__ �_.-. I
�f� � ..�-'--�---2 5/8"DIA I l ��� ' , .� 2 5/B°OIA.
2 5�16�� OIA — � HOLE lN CEILING I 2 5/16�� DIA — � HOLE lN CE/LING
CUP � � CUP—_I
..... . 0 VN 1 1/2' MAX. __.T..... � _. � FACE'OF Fl7T G
'� --�— FACE OF FlT7iNG , i.:.(
����� '� � , 70 FACE OF CEILINC
"" � 0(M ON
..�. _.
��J�r. 70 FACE OF C£IUNG ""„
...�..T� �:::::::� ENSi
�=�, �I ....I i i........_.. DIMFNSION � .� +
I
!'EILINC � �,iii.ii. "'�� --'.
--_ i�i���� � � CEILING • '•�•�•��
_^ _ ._._ i 5/76" N,AX. � I I -- 3�4„
1
1/2�� MAX. �
�s/�s" �covER no�us�ENr / i
CO�ER ADJUS7MEN7 , I � I � �
COVER PLA rE—I--
COVER Pi,4*E— � ASSEMBLY �_ 3 5/16"' DIA.
ASSEMBLY 3 5/76" DIA. -- �
SPRINKLER
SPRINKLER—�
CONCEALED. 1/2° ADJUSTMENT o>>��a�� CONCEALED 5�16" ADJUSTMENT o�»�
Figure 1 Figure 2
Installation Aid
A protective cap is included for use during installation. gagement. A choice of two cover plate assemblies provide I
Im orp tant:The F1 FR56 Sprinkler with Model CCP cover either 1/2"(13mm)or 5/8"(8mm)of cover adjustment,
plate is not an FM Approved combination, Do not install these sprinklers in ceiling which have positive
InstallatiOn pressure in the space above.
Quick response sprinklers are intended for installation as After a 25/e"(67mm)diameter hole is cut in the ceiling,the
specified in NFPA 13. Quick response sprinklers and stan- sprinkler is easily installed with the Model RC1 Wrench. A
dard response sprinklers should not be intermixed. Teflon*based thread sealant should be applied to the sprin-
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, kler threads only. The Model RC1 Wrench is then used to
F1 FRXLH & F1 FR28 Recessed �uick Response Sprin- engage the sprinkler wrenching surfaces and to install
klers are to be installed as shown. The Model F1 or F2 Es- the sprinkler in the fitting. When inserting or removing the
cutcheons illustrated are the only recessed escutcheons wrench from the sprinkler/cup assembly,care should be tak-
to be used with the Model F1 FR56, F1 FR56LL, F1 FR42, en to prevent damage to the sprinkler, p0 NOT WRENCH
F1 FR42LL, F1 FRXLH& F1 FR28 Sprinklers. The use of any ON ANY OTHER PART OF THE SPRINKLER. The cover
other recessed escutcheon will void all approvals and ne- plate is then pushed onto the cup. Final adjustment is made
gate all warranties. by hand turning the cover plate until the skirt flange makes
When installing Model F1 FR56, F1 FR56LL, F1 FR42, full contact with the ceiling. Cover plate removal requires
F1 FR42LL, F1 FRXLH & F1 FR28 Sprinklers, use the Model turning in the counter clockwise direction.
D Sprinkler Wrench. Use the Model GFR2 Wrench for install- After installation, inspect all sprinklers to ensure that there
ing F1FR56, F1FR56LL, F1FR42, FiFR42LL, FIFRXLH & is a gap between the cover plate and ceiling and that the
F1FR28 Recessed Pendent Sprinklers. Any other type of four cup slots are open and free from any air flow impedi-
wrench may damage these sprinklers. ment to the space above.
NOTE: A leak tight '/z" NPT(R1/2) sprinkler joint can be Concealed cover plate%up assemblies are listed only for
obtained with a torque of 8-18 ft-Ibs (10,8 -24,4 N-m). Do use with specific sprinklers. The use of any other concealed
not tighten sprinklers over maximum recommended torque. cover plate/cup assembly with the Model F1 FR56 Pendent
It may cause leakage or impairment of the sprinklers. Sprinkler or the use of the Model CCP Concealed cover
The Models F1 FR56/CCP & F1 FR56LUCCP Concealed plate assembly on any sprinkler with which it is not specifi-
Sprinkler use the'/z" orifice, Y2" NPT(R1/2), Model F1FR56 cally listed my prevent good fire protection and will void all
&F1 FR56LL Pendent Sprinkler with a threaded Model CCP 9uarantees,warranties, listings and approvals.
cup which is factory attached to the sprinklers. The Model Glass bulb sprinklers have orange bulb protectors to
F1FR56 Pndent is available in temperature rating of 135°F minimize bulb damage during shipping, handling and in-
(57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The stallation. REMOVE THIS PROTECTION AT THE TIME THE
Model F1FR56LL Pendent is available only in a rating of SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE
200°F(93°C).The concealed sprinkier assemblies are com- PROTECTION. Removal of the protectors before this time
pleted by the installation of the attractive low profile Model may leave the bulb vulnerable to damage. RASCO wrench-
CCP push on cover plate assembly, rated 135°F(57°C) or es are designed to install sprinklers when covers are in
165°F(74°C)for the F1 FR56 and 165°F(74°C)for the FIFR56 place. REMOVE PROTECTORS BY UNDOING THE CLASP
LL.The cover plate and sprinkler cup assemblies are joined BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO-
using a cover plate skirt with flexible tabs for threaded en- TECTORS.
"DuPont Registered Trade Mark
6.
Temperature Ratings Finishes �'>
' Sprinkler _ ______Standard Finishes___._.________
i Max.Ambient r -
�� Classification I Tem erature Bulb Color S rinkler Escutcheon Cover late�'�
' °C ,F Temp. Bronze I Brass
�� Ordinary � 57 135 100°F(38°C) Orange Chrome Plated Chrome Chrome
�' Ordinary � 68 j 155 100°F(38°C) i Red Polyester Plated White
��, Intermediate ; 79 � 175 150°F(66°C) Yellow Coated�^��5��6� White Painted
I Intermediate ; 93 ! 200 150°F(66°C) Green S ecial A lication Finishes
Hi h�'� ' 141 � 286 225°F 107°C Blue S rinkler Escutcheon Cover late�'�
I�'�Not available for recessed sprinklers. Bright Brass�3� Bright Brass Bright Brass
Black Plated Black Plated Satin
Escutcheon Data�'> Black Paint�2��6� Black Paint Off White
�'�SIN RA1435-cULus permits use with F1,F2 or FP escutcheons for"light Off White�2��6� Off White Black Paint
hazard"only,while FM limfls use for same hazard with F2 escutcheon only. Satin Chrome Satin Chrome Black Plated
�'�Other finishes and colors are available on special order.Consult the
Maintenance factory for details.Custom color painted sprinklers may not retain their
The Model Fl FR56, F1 FR56LL, F1 FR42, F1 FR42LL, UL Corrosion resistance listing.Coverplate custom paint is semi-gloss,
unless specified otherwise.
FIFRXLH and Model F1FR56, F1FR56LL, F1FR42, �z� cULusListedonly.
F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Sprinklers should �" 2oo°F(93°C)maximum.
be inspected and the sprinkler system maintained in accor- `°' �u�us i�sted °corrosion resistance�� applies to SIN Numbers RA1435
dance with NFPA 25. Do not clean s rinklers with soa and (HSV�, RA�a85(VSV�, RA�a25 (Upright), RA�414 (Pendent) and
P P RA1415(Pendent) in standard black or white. Corrosion resistance in
water, ammonia or any other cleaning fluids. Remove dust other polyester colors is available upon request.
by using a soft brush or gentle vacuuming. Remove any 'S' FM Approvals finish as"Polyester coated"applies to SIN Number
sprinkler which has been painted (other than factory ap- s RA1414,RA1435 and RA1425 in standard black or white.
plied) or damaged in any way, A stock of spare sprinklers �CBandVdSApprovedfinishappliesonlytoRA1425,RA1414andRA1475.
Ordering Information
should be maintained to allow quick replacement of dam- Specify:
aged or operated sprinklers. Prior to installation, sprinklers 1. Sprinkler Model
should be maintained in the original cartons and packaging 2 Sprinkler Type
to minimize the potential for damage to sprinklers that would 3. Orifice Size
cause improper operation or non-operation. 4. Deflector Type
Sprinkler Types 5. Temperature Rating
Standard Upright 6. Sprinkler Finish
Standard Pendent 7. Escutcheon Type
Conventional 8. Escutcheon Finish (where applicable)
Recessed Pendent 9. Cover plate Model
Vertical Sidewall 10. Cover plate Thread size
Horizontal Sidewall 11. Cover plate Temperature
Recessed Horizontal sidewall 12. Cover plate Adjustment
Concealed pendent 13. Cover plate Finish
Maximum Working Pressure Note:WhenModeIF1FR56Recessedsprinklersareordered,thesprinklers
175 psi(12 bar) and escutcheons are packaged separately.
100% Factory tested hydrostatically to 500 psi(34.5 bar)
7.
Reliable. . . For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers • Deluge valves
• Flush automatic sprinkfers • Detector check valves
• Recessed automatic sprinklers • Check valves
• Concealed automatic sprinklers • Electrical system
• Adjustable automatic sprinklers • Sprinkler emergency cabinets
• Dry automatic sprinklers • Sprinkler wrenches
• Intermediate level sprinklers • Sprinkler escutcheons and guards
• Open sprinklers • Inspectors test connections
• Spray nozzles • Sight drains
• Alarm valves • Ball drips and drum drips
• Retarding chambers • Control valve seals
• Dry pipe valves • Air maintenance devices
• Accelerators for dry pipe valves • Air compressors
• Mechanical sprinkler alarms • Pressure gauges
• Electrical sprinkler alarm switches • Identification signs
• Water flow detectors • Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection AssociaUon,Factory
Mutual Research Corporation,or other similar organizations and also with The provisions of governmental codes or ordinances whenever applicable.
Products manufactured and disVibuted by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign counVies.
Manufactured by
The Reltable Automatic Sprinkler Co.,Inc. � Recycied
i n (800)431-1588 Sales Offices Paper
� '� � (800)848-6051 Sales Fax
Revision lines indicate updated or new data.
(914)829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.10/13 P/N 9999970300