2012-00876 -; _ / ..esito Page 1 of 1
Corey Neubert
From: "Chris Plessel"<cplessel@bkbm.com>
To: <neubertc@comcastnet>
Sent: Tuesday,June 12,2012 10:56 AM
Subject: River Pointe Apartment Deck Ledge alternate
Cory,
Per you request,we reviewed an alternate to use the GRK RSS 5/16 x 4 fastener in place of the 5/8 lag screws at
the ledger board connection to the existing building. We recommend as an alternate, using the 5/16 x 4 GRK
RSS fasteners at 7"oc spacing in a W pattern.
Chris Plessel P.E.
Project Manager
BKBM Engineers
5930 Brooklyn Blvd.
Minneapolis, MN 55429
Direct 763-843-0455
Mobile: 612-206-6113
Main: 763-843-0420 Fax: 763-843-0421
E-Mail: cple sel@bkbm.cam Web: www.bkbm.corn