Loading...
PRE 2010 DOCSQ twin city testinq ana cimirmEmnq tanomtorL&ww014 — 662 CROMWELL AVENUE ,d"•tO"0j+. " ST PAUL. MN 55114 j T PHONE 612/646 -Mol REPORT OF: DENSITY TESTS OF COMPACTED FILL MARION HILLS ADDITI PROJECT: 52ND & PIERCE ST NE DATE: June 7, 1979 FRIDLEY, MINNESOTA REPORTED TO: Environmental Land Forms Inc COPIES TO:l�Pridley Building Inspector 4511 Colfax Ave South Minneapolis, MN 55409 Attn: Grant Guerri LABORATORY No. 11-4190 TEST NUMBER: DATE TAKEN: UNIFIED SOIL CLASSIFICATION: (Moisture -Density Sample Number) LOCATION: DEPTH BELOW FOOTING ELEVATION: DEPTH BELOW EXISTING GRADE: FIELD DENSITY DETERMINATION 1 June 4, 1979 Sand, fine to medium grained, a little grave-, brown(SP-S 1 Lot 12 H Rk 2 June 4, 1979 Sand, fine to medium grained, a little gravel, brown (SP -SM) -1 Lot 13 PH N 3 June 4, 1979 Sand, fine to medium grained, a little gravel, brown(SP-SM)-1 Lot 14 N sM 4 June 4, 1979 Sand, fine to medium grained, a little gravel, brown(SP-SM)-1 Lot 15 A 611 Method Density in Place By Nuclear Density Method "B.", ASTM:D2922-71 (44 Basis) Dry Density (pcf) 125.5 124 128 128 Moisture Content (%) 5.1 8.1 7.3 5.1 Plus #4 Material W 6 8 8 7 LABORATORY MOISTURE -DENSITY RELATION OF SOIL: Method ASTM:D698-70, Method "A" (44 Basis) Maximum Dry Density (pcf) 121.3 121.3 121.3 121.3 Optimum Moisture (°b) 9.5 9.5 9.5 9.5 COMPACTION TEST RESULTS: Compaction (i') 103.5 102 105 105 REMARKS: These.tests are only indicative of the compaction at the locations and elevations shown. AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS. AND AUTHOR- IZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL Twin City Tes ng and Engineering Laboratory, Inc. B `a,G Y • CITY OF 1 RIOLEY, SUBJECT 6431 UNIVERSITY AVE. NE. FRIOLGY, MN. 55432 46121 5713450 VARIANCES ADDRESS rx-Z� � - 77a DATE APPEALS COMMISSION: APPROVED DISAPPROVED DATE 14,H^ N0. CITY COUNCIL REVIEW: REQUIRED: rYES CITY COUNCIL: APPROVED DISAPPROVED DATE N0. STIPULATIONS: ..... .... .... ....... NAME �' l`g�� L421 r d e� RECEIPT No. � LO_ T NO. BLOC_ K NO. TRACT OR ADDITION LEGAL DESCRIPTION: VARIANCE•REQUEST(S): (Attach plat or survey of property showing building, variances, etc., where applicable) =� r - Section(s) of the City Code: List specific hardship(s) which requires the variance(s): ,�i���� �- ®� � ®T,. ,�-7 .., .► tee.... _ r - DATE —��-5 SIGNATURE_ ADDRESS TELEPHONE NO ����� VARIANCES FOR CITY USE ONLY Board members notified of meeting by May 10, 1985 List member , date notified. and 'Yes' or "No" for plans to atten hearing. ' Plan Gabel Name • Date* To Attend end I Barna. : Plemel r Gerou Betzold Person nuking appeal and the following property owners having property w— ithin 200 feet notified: Name (all 55421). By Whom M/M Stanley Prokopowicz-1350 52nd Avenue N.E.:, Phone Or Mail Notified M/M Keith Hedges -1340 52nd Avenue N.E: It M/M Carl Newqui'st, 1336 52nd Avenue N.E. . :ter • Ms. Emily L. Miller, 1330 52nd Avenue N.E. M/M Harvey Peterson, 1310 52nd Avenue N.E. M/M Bernt Westeren, 5222 Pierce Street N.E. Ms. Hildagard Lindberg, 5216 Pierce Street N.E. M/M Donald Ward, 5231 Fillmore Street. N.E. M/M Douglas White 5211 Fillmore Street N.E. M/M Theodore Raines, 5221 Fillmore Street N.E. M/M Richard Larson, 5210 Pierce Street N.E. M/M Donald Fulcher, 5206 Pierce Street e.E. I ' M/M Patrick Finn, �� `�'�£V. M/M Richard Tkaczik, 12323 Gladiola St. N. .A _— roan Rapids 55x33 M/M Joseph Vattinson, 5215 Pierce Street N.E. M/M D4vid Holmstrom 5241 Pierce Street. N.E. M/M Gary Cirks, 5230 Buchanan Street N.E. M/M Gary Major, 5220 Buchanan Street N.E. — M/M Charles Nara, 5170 Buchanan Street N.E. --�q�P Rema-ld _ M/M Michael Bock, 1345 52nd Avenue N.E. MH Paui Berff, 1345 &24W Avenue, W.9 —1 CITY OF FRIDLEY APPLICATION FOR PLUMBING AND GAS FITTING PERMIT RATE SCHEDULE PLUMBING FIXTURE RATES: NO. RATE Now Fixtures i Future Fixtures Old Opening, New Fixture Beer Dispenser Blow Off Basin Catch Basin Rain Water Leader Hydraulic Valve Sump Or Receiving Tank Yater Treating Appliance Hot Water HeaterU Gas Range Gas Dryer $ 5.00 $ 3.50 S 1.50 S 4.00 $ 5.00 6 5.00 S 5.00 $ 5.00 S 5.00 $ 7.00 $ 5.00 $ 10.00 $ 10.00 ALL OTHERS AND/OR REPAIRS AND ALTERATIONS It of Value of Fixture or Appliance Reinspection Fee $ State Surcharge (SI5.00) TOTAL FEE TOTAL 8 8 8 8 8 8 8 8 8 7DO 8 8 8 Bitective Aug. 1, i9bi sr y� Job Address --5�.20 2 - Department Department of Buildings City Of Fridley Tel. •571-3450 The undersigned hereby makes application for a Permit for the work herein specified agreeing to do all work in strict accordance with the City Codes and rulings of the Department of Buildings, and h eby declares that all the facts and representations stated in this appli tion are true and correct / Fridley, Mn. 1960 OWNER?/.4�J2`cf /,yN C�i�IF/E D/fe��-.�•d.�% KIND OF BUILDING �%Q/y1Lr USED AS TO BE COMPLETED ABOUT �'� 3/—� % �• ESTIMATED COST 4 NEW BU LDING PERMIT NO. PERMIT NO. Company Signed By Tel. No. ROUGH INSP. Date FINAL INSP. 9,- x 2 J, 7 Date APPROVAL FOR PERMIT HINIHUM FEE FOR ANY PLUMBING PERMIT IS $10.00 PLUS THE 8.50 STATE SURCHARGE r N o, c o a o Water +e+ a� e 1R C w F R go X u 4e C ++ H w q w Heater t m W pw O C m awi uC a m kO e rn u a ani ri< in ai w CCCr+o w U 3 gg tai ,as lec lot 2nd ]rd h (R) - Future Connection Opening Connected with Sewer (*) - New Fixture, Old Opening Water RATE SCHEDULE PLUMBING FIXTURE RATES: NO. RATE Now Fixtures i Future Fixtures Old Opening, New Fixture Beer Dispenser Blow Off Basin Catch Basin Rain Water Leader Hydraulic Valve Sump Or Receiving Tank Yater Treating Appliance Hot Water HeaterU Gas Range Gas Dryer $ 5.00 $ 3.50 S 1.50 S 4.00 $ 5.00 6 5.00 S 5.00 $ 5.00 S 5.00 $ 7.00 $ 5.00 $ 10.00 $ 10.00 ALL OTHERS AND/OR REPAIRS AND ALTERATIONS It of Value of Fixture or Appliance Reinspection Fee $ State Surcharge (SI5.00) TOTAL FEE TOTAL 8 8 8 8 8 8 8 8 8 7DO 8 8 8 Bitective Aug. 1, i9bi sr y� Job Address --5�.20 2 - Department Department of Buildings City Of Fridley Tel. •571-3450 The undersigned hereby makes application for a Permit for the work herein specified agreeing to do all work in strict accordance with the City Codes and rulings of the Department of Buildings, and h eby declares that all the facts and representations stated in this appli tion are true and correct / Fridley, Mn. 1960 OWNER?/.4�J2`cf /,yN C�i�IF/E D/fe��-.�•d.�% KIND OF BUILDING �%Q/y1Lr USED AS TO BE COMPLETED ABOUT �'� 3/—� % �• ESTIMATED COST 4 NEW BU LDING PERMIT NO. PERMIT NO. Company Signed By Tel. No. ROUGH INSP. Date FINAL INSP. 9,- x 2 J, 7 Date APPROVAL FOR PERMIT HINIHUM FEE FOR ANY PLUMBING PERMIT IS $10.00 PLUS THE 8.50 STATE SURCHARGE r SUBJECT PE City of Fridley r. G 18 5 5 4 AT THE TOP OF THE TWINS BUILDING PERMIT r RECEIP i L'COMMUNITY DEVELOPMENT DIV. r PROTECTIVE INSPECTION SEC. i CITY HALL FRIDLEY 55432 L , NUMBER REV. DATE PAGE OF APPROVED BY ----� ,; 612-571-3450 910-F15 7/23/86 10B ADDRESS 5202 Pierce Street N.E. 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 12 1 Marian Hills Addition SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Pat/Arlene Finn 544-1234 3 CONTRACTOR MAIL ADDj9ESS ZIP PHONE LICENSE NO, Comfort'Suilders Inc. 10001 Ives Lane, Maple Grove, PIN 55369 522-3691 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE" LICENSE NO. 6 USE OF BUILDING Residential 7 CLASS OF WORK NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 8 DESCRIBE WORK Construct a 2,000 sq. ft. Dwelling and a 704 sq. ft. Garage SEPARATE PERMITS FSE 9 CHANGE OF USE FROM ntATING, PLUMBING AND $I STIPULATIONS Front Yard variance reapproved on July 21, 1986. Provide a hard surface driveway. Provide sod in the front and side yards. Provide City with copy of verifying survey before capping. Soil tests may be required prior to pouring footing SEWER LOCATION: "Y" is 80' SW from Manhole on property line. Expose Wye prior to establishing minimum footing elevation. WATER LOCATION: Near south culdesac line. Valve may be exposed. DRIVEWAY CURB CUT: If Necessary: $13.50 per foot ��� THE CITY OF FRIDLEY DOES NOT GUARANTEE THE NO �e� ACCURACY OF UTILITY LOCAtIONS AND ELEVATIONS. j 1�fil(tj@o THIS DATA Ii FOA INFORMATION PURPOSES ONLY, AND PERSONS USING THIS INFORMATION SHOULD OWWRED g* LAV,- VERIFY IT ON THE SITE• SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD VENTILATING OR AIR CONDITIONING. Wood Frame THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT R-1 ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $159,050 $79.53 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- $ 583.00 $475.00 STRU N O THE PERFORMA CE OF CONSTRUCTION. PLAN CHECK FEE TOTALFEE �.: 7, �p $145.75 $1,283.28 SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT IDA EIWHEN PROPERLY V IDATED THIS IS YOUR PERMIT BLDG IN5o gA7E SIGNATURE OF OWNER IIF OWNER BUILDER) IDATEI NEW 06 City of Fridley Effective 4/1/86 ADDN. [ ] R-1 AND R-2 ALTER. [ ] Building Permit Application Construction Address: to -a I \ eyC-e- Legal Description: 3 c3r Owner Name & Address: � Avkv�e. � �v® Tel. # S yV-03 Contractor: CDrrm�Clv Tel. # --5DA- 3Cra / Address: 10nO ��r�� i ✓�,�-pew ��'©�i� �� �o�' Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF IMPROVEMENT LIVING AREA: Length Width Height Sq. Ft. Z<NcJc) GARAGE AREA: Length Width Height Sq. Ft. 7v DECK AREA: Length Width Hgt/Ground Sq. Ft. OTHER: Corner Lot [ ] Inside Lot [X Ft. Yd. Setback Side Yard Setback Type of Construction:k V'jl---) Estimated Cost: $ �— Approx. Completion Date: Alt. A Alt B Proposed Driveway Width If New Opening Is Desired: $ $ See Back Page for Explanation DATE: APPLICANT: Tel. CITY USE ONLY Permit Fee Plan Check State Surcharge SAC Charge Park Fee Sewer Main Charge TOTAL STIPULATIONS: � — S�•ts Scke $ /C)60 3, 1)0 Fee Schedule on Reverse Side 25% of Building Permit Fee $.50/$1,000 Valuation $475 per SAC Unit Fee Determined by Engineering Agreement Necessary [ ] Not Necessary Z0i68 Rc- qV,rtrw a -t uv, TJ s - mti Via— — 01 U e)`4 i , CITY OF FRIDLEY ` APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES RATE SCHEDULE - RES I DENTIA L RATE TOTAL Job Address OCIP Furnace Shell and Duct Mork, (Alen replacement furnace) $ 20.00 $ Department of Buildings bill University Ave. N.L.. Fridley, NN S5412 Burner City of Fridley Gas Piping $ 10.00 S �b�m Tel. 0571-1450 Iping needed with mer furnace) $ 10.00 $ The undersigned hereby nuke/ application for a permit for the Work herein Range specified agreeing to do all Work In strict accordance with the City Codes Gas Dryer $ 10.00 $ and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct. • Air Conditioning (all sizes) $ 10.00 $ Fridley. farm. /m? -3o _• l'�� Ij All Others/Repair@ and Alterations OWNER Q /ieC^tC It of Value of Appliance or Mork Sri RIND OF BUILDING -- COMf1ERCIAL/INDUSTRIAL 1 USED AS PP `U;'i� It of Value of Appliance or Mork S TO at COMPLETED ABOUT r�f3 Z S ESTIMATED COST State Surcharge $ .SO pff - NEM @UILDIMG PERMIT ND. fERl1IT N0. WTAL rn S S.�p,S Reinspection tee (S1S.00) DESCRIPTION OF FlfftNACE/BURNER Rough Insp. HEATING or POWER PLANTS. Stem Not ester Mann Air- No. Date None �/ = i� /1%G�W/a alae No. / / � S ?�� Trade - Final In@p. Sri /?_ Kn►� NP Date Capacity Sq. Ft. EDR Approval for Permit i Total Connected toad Rind of Fuel IV4 f 6A s BUMMER - Trade Name Size No. Capacity Sq. Ft. EDM BTU RP MIN)MUM FEE FOR ANY HEATING PERMIT IS $10.00 Company PLUS S. SO STATE SURCHARGE Signed y Attach stack verification fors with replacnnent furnace Isermits Tel. •Air Conditioners can not In- placed in -:td.• yard vitlsout. rntten I"mts%ton frnn adp.tning netglu■ir. ROBERTS-HAMILTON COMPANY HEAT LOSS CALCULATIONS MINNEAPOLIS. MINN. Weatherstrips AS.H.V.E. Construction No. Insulation Guide Windows I Doors Reference Out. Wall I Int. Wall I Ceiling I Roof I Floor Kind I How Applied Yes—No Yea --No 19 Fl.l Room I Length Width Height AFI.1 Room i Length,3 O Width 2 V Height /,Z Windows and Doors—Crarkage and Area Windows and Doors—Crackage and Area Width Height No. of final ft. Area I Width Heialu No of Linal ft. Ara I No. of pane of pane lights of crack so. ft. No. of ane of Dane lights I of crack so. ft. I I I I I Coef. Btu Infiltration Glass Exp. wall Net ezp. wall Int. wall Ceil.or floor Total Btu. Required sq. ft. E.D.R. or eq. ins. W.A. Leader area FI.1 Room I Length. ? / Width 11a Heiaht % Windows and Doors—Crackage and Area lCoef. Btu Width Height No of Lina) ft. Area No. of pane of pane lights of crack sq. ft / /,v 4 3® f,/ fr6 Glass Ezp. wall (,f! Coef. Btu Infiltration 3 t9 Int. wall $ 3,3- Ylab Glass pl?_ 00 Coil. or floor ,`� .10 Total Btu. • Ezp. wall d.2 4 1 a Required sq. h. E.D.R. or. sq. ins. W.A. Leader area �pu F1.I� aQS Room I Length /0 Width 7 Height.? < Net exp. wall Ceil. or floor Ceil. or floor I q 9 1 Int. wall Ceil. r floor Total Btu. Required sq. ft. E. D.R. or sq. ins. W.A. `Leader area 3 iN Fl.j -13A174 Room I Length /S Width 5- Height /Z Windows and Doors—Crackage and Area 3 0 Width I Haght No. of Lmea1 ft. Area I No. of Dane of Dene lights of eraclt so. ft. :7 Infiltration-- Glass nfiltrationGlass Exp. wall 4MR yo Net exp. wall , Q /41 Int. wall Totalr' / -Required sq.h.E.D.R.oreq.ins.W.A.Leaderarea W6 I I I I lCoef. Btu Infiltration ' 0 3e Glass Ezp. wall (,f! Infiltration Net exp. wall &®U 3 t9 Int. wall $ 3o- Exp. wall 00 pl?_ 00 Coil. or floor Pe G le 0 Total Btu. d.2 4 1 a Required sq. h. E.D.R. or. sq. ins. W.A. Leader area F1.I� aQS Room I Length /0 Width 7 Height.? < Windows and Doors—Crackage and Area idth eight No of Linal (t. Area No. of pate of pane lights of crack sq. it. Width Height No. of Litxd k. Area No. of pane of pari lights of crack sq. k. 0 3e Coef. Btu Infiltration / 3,5- :5-6,0 Glass $ 3o- Exp. wall Exp. wall Net. exp. wall Net exp. wall /1 Int. wall Ceil. or floor Ceil. or floor I q 9 1 v Total Btu. Required sq. ft. E.D.R. or sq. ine.W.A. Leader area I(� e FI.1,4Q �,e Room I Length 7 Width 7 Height Windows and Doors—Crackage and Area idth eight No of Linal (t. Area No. of pate of pane lights of crack sq. it. 3 � ?J �® Coef. Btu Infiltration .70 3 S Glass .2 / .700 IJO 6, J Exp. wall & Net. exp. wall Int. wall Ceil. or floor I q 9 1 v oB t u I.,j L/ 4.,c Required ag.ft.E.D.R.oraq.ins.W.A. Leaderarea &t I • HEAT LOSS CALCULATIONS ROBERTS-HAMILTON COMPANY Weatherstrips A.S.H.V.E. Construction No. Guide J MINNEAPOLIS. MtNN. Insulation Windows1-Yes--No Doors Reference 11I Out. Wall ( lat. Wall eiling I Roof I Floor Windows and Width No. of pane 1Y Kind I How Applied Yes—No Btu 19 J_S� c 1 q 30 0 Exp. wall Exp. wall Ivy Ceil. or floor / F1.1 E;V*y, Room I Length 6 Width Height 13 F1.1 '&&/ Room I Length 2 3 Width T3 Height Winc, ows and Doors—Crackage and Area �- �� Windows and Doors —Crackage and Area b C� Width He1ght Nn. of incl ft. Area [ �(/ No4 of pane of pane lights of crack sq. ft. ®�� Ceil. or floor Width No. of pane tight No of LOT h. of pane lights LOT!! Area sq. ft. / O Required sq.h.E.D.R.orsq.ins.W.A.Leaderarea / )90 1/90 V 6 / I Y % I i/,K- I It, S I I I I I Coef. Btu Infiltration Glass Exp. wall 228 Net exp. wall 902 Iq 7 70 Int. wall ail. r floor "Orotal Btu. Required sq. ft. E.U.R. or sq. ins. W.A. Leader ares 1 Fl.i' ./ LL Room 1 Lenath T Width 3 Heiaht Windows and Doors—Crackage and Area I I JCoef. Width Haght No of Lineal ft. Area No. of pane of= lights of crack sq. ft Required sq. ft. E. D.R. or sq. ins. W.A. Leader area 1 '-? 1 Fl.j),QLjkjhp4Room I Length (; Width Height Windows and Width No. of pane 1Y Doors—Crackage and Area Height No. of Lineal ft. Arca of pane lights of crack sq. (t. 34,/ Coef.Btu Infiltration % Btu 3 Glass c 1 q 30 0 Exp. wall Exp. wall Ivy Ceil. or floor Net exp. wall 13 3 �. Int. wall Required sq. ft. E.D.R. or. sq. ins. W.A. Leader area / 17I.1&AA A7- Room I Lenath Z/ Width / 8 Heiaht Ceil. or floor Int. wall Ceil. or floor / O Required sq.h.E.D.R.orsq.ins.W.A.Leaderarea Total Btu. I I JCoef. /S o S' Required sq. ft. E. D.R. or sq. ins. W.A. Leader area 1 '-? 1 Fl.j),QLjkjhp4Room I Length (; Width Height Windows and Width No. of pane 1Y Doors—Crackage and Area Height No. of Lineal ft. Arca of pane lights of crack sq. (t. 34,/ 3 �2 Re Coef. Btu Infiltration 33-1 c Glass ® `j Exp. wall Ivy Ceil. or floor Net exp. wall 13 3 Int. wall Required sq. ft. E.D.R. or. sq. ins. W.A. Leader area / 17I.1&AA A7- Room I Lenath Z/ Width / 8 Heiaht Ceil. or floor Int. wall Total Btu. / O Required sq.h.E.D.R.orsq.ins.W.A.Leaderarea / D.S6 I I I I JCoef. Btu Infiltration S I(A Glass V6, 3 Q /3 crp Exp. wall �2 Re Btu Net exp. wall 10 1411S-0 Int. wall / Fl g 0 Glass ---294 Y& 30 Ceil. or floor Exp. wall 3 57 Total Btu. Required sq. ft. E.D.R. or. sq. ins. W.A. Leader area / 17I.1&AA A7- Room I Lenath Z/ Width / 8 Heiaht Windows and Doors—Crackage and Area 8 Width eight No. of Lineal ft. Ara No. of of pane lights of crack sq. ft. y s ys / 3F 3/ / 3 Coef. Btu Infiltration /7,3 3 S / Fl g 0 Glass ---294 Y& 30 1-396 Exp. wall 3 57 31.2 Net exp. wall .2 (o(/j' y Int. wall )90 1/90 V 6 Ceil. or floor / / 90h Total Btu. 1XZ S Required sq. ft. E.D.R. or sg. ins.W.A. Leader area V f3 Fl.ISt)1,4Q . Room I Lenxth / 9 Width 717 Heiaht H Windows and Doors—Crackage and Area C Width Height No ofLineal ft. Area No. of pane of pane lights of crack sq. (t. G / 3 Coef. Btu Infiltration /7,3 3 S (a OSS Glass ---294 3 0 1i/(®.20 Exp. wall 3,4R Net. exp. wall Int. wall )90 1/90 V 6 Cei . or oo / / 90h To Btu. / -9 Viso Required sg. h. E.D.R. or sg. ins. W.A. Leader area ,Z q/ ROBERTS-HAMILTON COMPANY HEAT LOSS CALCULATIONS MINNEAPOLIS. MINN. Weatherstrips A.S.H.V.E.. Construction No. Insulation Guide WindowsI Doors Reference Out. Wall j Int. Wall I Ceiling j_.!10_0f I Floor Kind I How Applied Yes—No Yea --No 19— X 9 X Fl.l Room I Length Width 9 Height F1.1CA&g6T Room I Length 8 Width Height Windows and Doors—Crackage and Area Windows and Doors—Crackage and Area Width Haght No. of ineal h. Ara Width Height No. of Lineal ft. Ara I No. of pane o! pane li rs of crack sg. !t. I No. of pane o! pane lights l of crack I q. h. Coef.I Btu Infiltration 1.2,T JSO Glass 41 0 / 91 ® 9 b Exp. wall % Net exp. wall 91Vs Infiltration Int. wall (o Glass 3010 3 Ceil r floor / Total Btu. --f207,0-v- / / Required sq. ft. E.U.R. or sq. ins. W.A. Leader area FIJM. AA -Al Room I Lenath 11 Width ) / Height Windows and Doors—Crackage and Area s ry t,,d g/r WidthHe�ghc Nn Of Lineal ft. Area No. of pane Intl lights of crack sq. ft 41 0 / 91 ® 9 b o Coef. Btu Infiltration Infiltration (o Glass 3010 3 3 u 9,& Exp. wall / Exp. wall Net exp. wall 2.2 Int. wall 1 Int. wall Ceil. r floor / / 7/ —FF _!% a Btu. -2070 V p Required sq, ft. E. D.R. or sq. ins. W.A. Leader area " Fl.:,M-%)ttw,Room I Length $ Width 5' Height Windows and Doors—Crackage and Area Width I Height No. of Lined ft. Ara 2 No. of para of para lights of creek aq. (t. I - Glass 3 ® 1 /.?-0 Exp. wall /0 to Net exp. wall Int. wall Lor floor Boor i otal Btu. r / Reouired s4. h. E.D.R. or sia.ins. W.A. Leader area ' 2 D.S6 I I I I I ICoef.I Btu Infiltration Glass Exp. wall Net exp. wall `v Int. wall Ceil. r floor P. .2 To—tai Btu. ge / 0 Required sq. ft. E.D.R. or. sq. ins. W.A. Leader area Z F1.1 AIN Re.. I Length A, Width J -2 Height Windows and Doors—Crackage and Area Oi— Width ieight No. of Lineal h. Ara No. of party of pane lights of crack . sq. h. 30 ® 9 b o Coef. Btu Infiltration (o 3T 3010 Glass 3 Exp. wall ,2 2.2 Net exp. wall 1 Int. wall Ceil. Ir floor 19,2- 1/ '771) Btu. imcquirca sq. rr. c.L.n. or sq. rens. w _m. L -eager area 1 1!&e .Z F1.1 14. G 04% Room I L-ensrth J 9 Width /.T_ Height Windows and Doors--Crackage and Area Oi— Width eight No of Lineal ft. Area No. of park of pane lights of crack sq. ft. 3D Coef. Btu Infiltration Glass Ezp. wall a 4p¢ Net. ezp. wall Int. wall Ceil. or floor 's ij 10.0,/-) Total Btu. ins. W.A. Leader area Coef.I Btu Infiltration I H. 4 t / y' Glass S-28 Exp. wall '� Net exp. wall Int, wall Ceil.or floor I Total Btu. Required sq. ft. E.D.R. or sq. ins. W.A. Leader area FI.1 Room I L.eneth Width Height Windows and Doors=Crackage and Area 5 Tb M L Width Haght No of Lineal ft. Area No. of pane of pare lights of crack sq. ft ROBERTS-HAMILTON COMPANY GG// HEAT LOSS CALCULATIONS Infiltration MINNEAPOLIS.• MI1IN. Weatherstrips A.' H.V.E. Exp. wall 2 Construction No. Insulation Net exp. wall Guide Ceil. or floor Windows I Doors Reference Out. Wall I Int. Wall I Ceiling I Roof I Floor KindI How Applied Yes—No Yes—No 19 I Fl.l Room I Length Width Height F1.1 Room I Length Width Height Windows and Doors—Cracks a and Area i g4 �� Windows and Doors—Cracks a and Area Width HritT No. gLireal ft. Ara G Width Height No. of Lineal ft. Area No. of pane of parte li s of nock p. [t. it of No. of pone of pane lights of crack p. h. { �Q v 47 z Coef.I Btu Infiltration I H. 4 t / y' Glass S-28 Exp. wall '� Net exp. wall Int, wall Ceil.or floor I Total Btu. Required sq. ft. E.D.R. or sq. ins. W.A. Leader area FI.1 Room I L.eneth Width Height Windows and Doors=Crackage and Area 5 Tb M L Width Haght No of Lineal ft. Area No. of pane of pare lights of crack sq. ft Coef. Btu Infiltration g Glass B Z® Exp. wall 2 , Net exp. wall Int. wall Ceil. or floor Total Btu Required sq, ft. E. D.R. or sq. ins. W.A. Leader'area FIJI Room I Length Width Height Windows and Doors—Crack,age and Ares '� Width Heittht No. of Lina) ft. Area No, of pant of pane lights of crack sq. ft. ra Coef. Infiltration Glass Exp. wall Net exp. wall Int. wall rp] Ceil. or floor Total Btu. Required sq.ft.E.D.R. or sq.ins. W.A. Leader area D.S6 11 Coef.I Btu Infiltration Glass Exp. wall – / 3,g T07 Net exp. wall Int. wall Ceil. or floor I Total Btu. Required sq. ft. E.D.R. or. sq. ins. W.A. Leader area Fl.1 Room. I L.enath Width Height Windows and Doors—Crackage and Area Width HNo. of Luteal ft. Ara No. or Done— Of= lights of crack sq. k. Coef. Btu Infiltration Glass , Exp. wall Net exp. wall Int. wall Ceil. or floor Total Btu. Ikequired sq. ft. E.D.R. or sq. ine.W.A. Leader area I FI.1 Room I Length Width Height Windows and Doors—Crackage and Area Width eight of Lineal ft. Area NO. of nave of cane lights of trach — h Infiltration Glass Exp. wall Net. exp. wall Int. wall Ceil. or floor Total Btu. Leader Btu AW lip CIiYOF FRIDLEY CIVIC CENTER • 6431 UNIVERSITY AVE. N.E. FRIDLEY, MINNESOTA 55432 • PHONE (612) 571-3450 March 4, 1987 Mr. Pat Finn 5202 Pierce Street N.E. Fridley, M[Q 55421 Re: Final Inspection at 5202 Pierce Street N.E. Dear Mr. Finn: A final inspection was conducted on March 2, 1987 of the above address and the following items were noted which must be completed before the structure can be f inaled out: 1. Provide City with copy of verifying survey by March 20, 1987. 2. Provide combustion air to furnace roam by March 20, 1987. 3. Install stair or barricade opening to storeroom Linder garage by March 20, 1987. 4. Provide a cover over the attic access in the garage by March 20, 1987. 5. Clean the debris from the front yard by March 20, 1987. 6. Provide sod in the front and side yards by July 1, 1987. 7. Provide a hard surface driveway by July 1, 1987. We will expect the above items to be completed by the scheduled dates when reinspections will be conducted to determine compliance. If you have any questions on these items, please feel free to contact me at 571-3450. Sincerely, DARREL G. CLARK Chief Building Official DGC/mh Richard Tkaczik Construction Inc. 12323 GLADIOLA N.W. COON RAPIDS, MN 55433 (612)421-9009 March 17, 1989 City of Fridley: I Pat Finn Sr. of 5202 Pierce St. N.E.-Fridley, Minnesota do not object to the placement of the air conditioner to be installed at 5201 Pierce St. N.E.-Fridley, Minnesta. CITY OF FRIDLEY INSPECTION DIVISION 15'�1� I �S V 6431 University Ave NE (" Fridley, MN 55432 APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, 572-3604 REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES Effective On , JOB ADDRESS RATE SCHEDULE The undersigned hereby makes application for a permit for the work herein Residential Rate TOTAL specified agreeing to do all work in strict accordance with the City Codes and Furnace Shell and Duct Work, Burner — rulings of the Building Division, and hereby declares that all the facts and Also Replacement Furnace $ 30.00 $ representations stated in this application are true and correct. (Side Vent — Fill Out Back) a r AUG! 3 '3 188 Gas Piping (Needed with new furnace) $10.00 $ OWNER, Gas Range $10.00 $ / BUILDING USED AS Gas Dryer $10.00 $ ESTIMATED COST PERMIT NO. "7 *Air Conditioning — All Sizes $ 25.00 $ DESCRIPTION OF FURNACE AND OR BURNER All Others/Repairs $ Alterations (LIST ON BACK) 1% of Value of Appliance or Work $ No. of Heating Units Circle One (Steam) (Hot Water) (Warm Air) Trade Name Size No. Commercial/Industrial BTU HP EDR 1.25% of Value of Appliance or Work $ Fuel Total Connected Load State Surcharge $ .50 Burner Trade Name Size No. BTU HP EDR TOTAL FEE $ � -� .RICMIOID £_ SONS ELEC> C� T. 'fFntaG.aA ` HEATING COMPANY alba:OLI�EI�F x MINIMUM FEE FOR ANY HEATING/COOLING/VENTILATION CXy " ,r' �� 1100 REFRIGERATION/AIR CONDITIONING PERMIT IS $25.00 Signed By j' ;`��° Tel No. PLUS THE $.50 STATE SURCHARGE REINSPECTION FEE $42.00/Hr Approved By Rough—In Date Final Dat *Air Conditioners can not be placed in a side yard without FILL OUT BACK SIDE FOR ST K VERIFICATION ON written permission from adjoining property owner. REPLACEMENT FURNACE List ALTERATIONS Being Done: HEATING CO: Signed By: Date: I CEMWgEY AND STACK VERIFICATION The undersigned hereby verifies that the existing chimney or stack: 1. Has been carefully examined Yes () No ( ) 2. Is free from rust or deterioration Yes () No ( ) 3. Has no foreign objects lodged within Yes( ) No ( ) 4. Is securely supported Yes ( ) No ( ) 5. Meets all current Code requirements for size and total BTU's connected Yes () No ( ) 6 Has total heating BTU's of All other BTU's TOTAL BTU's 7. Has a liner been provided for water heater Yes () No ( ) 8. Has combustion air been provided for water heater Yes () No ( ) Remarks: List ALTERATIONS Being Done: HEATING CO: Signed By: Date: I CIIYOF FRIDLEY FRIDLEY MUNICIPAL CENTER • 6431 UNIVERSITY AVE. N.E. FRIDLEY, MN 55432 • (763) 571-3450 • FAX (763) 571-1287 February 21, 2003 Mr. Robert Engler 5202 Pierce Street NE Fridley, MN 55421 Re: Final Inspection at 5202 Pierce Street NE Contractor: Golden Valley Heating & Air Dear Mr. Engler: A mechanical permit was issued on August 15, 2001 to install an air conditioner at your address. According to the 1991 Uniform Mechanical Code a final inspection shall be conducted on the work authorized by this permit. As of this date the inspection has not been requested. The permit fee that was paid covers the inspection to make sure the work was completed according to the Codes. We will keep your permit open for another 30 days and if we do not hear from you within this time to set up the inspection, we will mark the permit "no inspection called for by homeowner after notification" and take no further action. To set up the inspection or to have any questions answered, please contact the Building Inspection Division at (763) 572-3604. Sincerely, DJ/mh