PRE 2010 DOCSGEOTECHNICAL ENGINEERING 1925 Oakcrest Avenue Roseville, Minnesota 55113 PROJECT: REPORT OF SUBSURFACE INVESTIGATION W0WQ1VVD1 PROPOSED RESIDENCE ROTTLUND COMPA-M,-, INC. VILE 8100 RUTH STREET P.O. BOX 32082 FRIDLEY, MINNESOTA FRIDLEY, MINNESOTA 55432 GEC JOB IVO. 1083 CC: SUBURBAN ENGINEERING DATE: MAY 28, 1976 INTRODUCTION As requested by Suburban Engineering, we conducted a subsurface investigation at this project on May 25, 1976. Three test borings were drilled. Based on the results of the borings, we have provided recommendations for design and construction of the building foundation and floor slab. The location of the building and general site conditions are illustrated on the attached drawing. We understand that the building will be two story. The lower level will be a walk -out to the west. This level will be approximately 20" below Ruth Street. There is a terrace retaining wall system west of the house. The wall is constructed of railroad ties. The wall leads down to a creek. We assume that the building will be of conventional design, with normal tolerance to settlement, and constructed in accordance with applicable building code requirements. Deviations from the above design information and assumptions could necessitate altering our recommendations. HYDROLOGY • SOIL AND FOUNDATION ENGINEERING • TEST BORINGS MATERIALS TESTING • PERCOLATION TESTING • ENGINEERING GEOLOGY • CONSTRUCTION INSPECTION GEC #1083 Page 2 TEST BORINGS The boring locations are shown on the attached sketch. The borings were made using the standard penetration - split spoon, thin wall tube, and static cone methods. Additional information regarding the test boring procedure is on the attached sheet. The soils were classified in accordance with the ASTM Visual - Manual Method (ASTM D 2488). Logs of the borings are attached. Each log shows: the depths to the boundaries between the soil layersT the description, classifica- tion, and geologic identification of the sails; the surface eleva- tion at the boring; water level measurements; the standard penetra- tion resistance (N column), the results of laboratory tests; the results of static cone tests; and other information. Sheets describing terminology used on the logs are attached. The elevation of the ground surface at the borings was determined in reference to the centerline of Ruth Street. An assumed bench mark elevation of 100.0' was used there. SUBSURFACE CONDITIONS The soil profile encountered in the borings consists of fill over sandy coarse alluvium over sandy clay and clayey sand glacial till. (Refer to the attached sheet for a description of geologic termin- ology.) The fill is mostly silty sand. Leaves were present in the fill in Boring #2. Based on the presence of the leaves and low penetration resistance, it is apparent that the fill is uncontrolled. Geotechnical Engineering Corporation The ground water table was encountered in the borings at about elevation 89. Water was seeping out through the retaining wall. The elevation of the water surface at Rice Creek was at 828. Apparently the ground water table slopes down steeply toward Rice Creek and, in fact, intersects the surface along the retaining wall. DISCUSSION AND RECOMMENDATIONS The natural soils should provide suitable support for the building and floor slab. Based on the results of the field and laboratory information, we recommend a design bearing pressure of up to 1000 psf for footings. All fill should be removed from below the proposed building. The surficial fill should be replaced with compacted fill. The excava- tion should be oversized on a 1 : 1 ratio beyond the edge of proposed footings. The fill material should be sandy, compacted to at least 95% of standard proctor density. Footing elevations can be lowered to reduce the amount of excavation and filling in the oversized area. As discussed with Suburban Engineering, consideration should be given to evaluating the stability of the slope behind the retaining wall. As requested, we have not conducted such an analysis in the present investigation. Subsurface conditions can vary from that encountered in the borings. Depending on the extent of the variability, this could necessitate altering our recommendations and the cost of construction. Additiona.' exploration will be needed to evaluate the extent of the variability. CLOSURE Report Prepared By: 4� Robert E. Pendnrgast, P.E. Minn. Reg. No. -8450 Geotechnical Engineering Corporation GEC JOB -IO: 1083 VERTICAL SCALE: 1'..3° LOG OF BORING NO: 1 PROJECT: HOUSE FOUNDATION, 8100 RUTH STREET, FRIDLEY, MINNESOTA DEI P'TH° SURFACE ELEVATION:97.0 N �B AMPLE �J REC FIELD& LABORATORYTESTS FEET DESCRIPTION AND CL IFICATION GEOLOGY TYPE MC DEN I P. L. 1 SILTY SAND medium grained, grayish brown, (nonplastic -SM) 3- 4 SAND 'medium grained, DEPTH FILL 1 1 6 N N N SS SS SS 12 12 12 COARSE gray, ALLUVIUM MATER LEVEL 5/25 A.C. (Sp -SM) 14.0 13.5 5/25 1045 4 Y SS 18 8.0 BOf11 fV G COMPLETED: 5/25/76 5/25 1-1 2:07 11.0 7.7 CREW CHIEF: S•B-RIG: BoMb g 10- 5 Y SS 12 11- SANDY CLAY with a little gravel, TILL 12- gray` 5 Y SS 18 (CL) 13- 14- 15- 5 Y SS 18 16 --END END OF BORING 7- 17- Is- 18- 19- 19- 20- 20-21- 21- DEPTH DRILLING METHOD WATER LEVEL MEASUREMENTS ®-14%: HSA 2 ®ATE TIME SAMPLED DEPTH CASING DEPTH CAVE-IN DEPTH DRILLING MUD LEVEL MATER LEVEL 5/25 A.C. 16 14.0 13.5 5/25 1045 8.0 BOf11 fV G COMPLETED: 5/25/76 5/25 1-1 2:07 11.0 7.7 CREW CHIEF: S•B-RIG: BoMb NOTE: REFER TO THE ATTACHED SHEETS FOR AN EXPLANATION OF TERMINOLOGY ON THIS LOG GEC JOB -NO: 1083 VERTICAL SCALE: 1^=3' LOG OF BORING NO: 2 PROJECT: _ HOUSE_F"OUNDATION, 8100 DEPTH, SURFACE ELEVATION: 0A In FEET DESCROPTOON AND CLASSIFOCATION SILTY SAND 1 medium grained, grayish brown, 2 (SP -SM) 3 SILTY SAND medium grained, 4 dark, contains leaves SAND, medium grained, s grayish brown, .(SP) B 1 o - SANDY CLAY with a little gravel, 11- gray, (CL) 12- 13- 14- 15- 16- END OF BORING 17- 16- 19 - 20 - 21 JTH STREET, FRIDLEY, MINNESOTA AMPLE I FIELD & LABORATORYTESTS GEOLOGY N WB TYPE REC. MC DEN I PL qc 1 IN I SS 0�� 8 e8 -5 ? SS COARSE ALLUVIUM 48 s 8 TILL 5�� S S Y .-c 8 <8 6 1 Y I SS 20"Nom 6IYI SSI 1110 DEPTH DRILLING METHOD WATER LEVEL MEASUREMENTS NOTE: REFER TO THE ATTACHED SHEETS FOR AN EXPLANATION OF 0-14% : HSA DATE TIME SAMPLED DEPTH CASING DEPTH CAVE-IN DEPTH DRILLING MUD LEVEL WATER LEVEL 1:00 16 13.0 11.7 _5Z25 5 2 5 1:45 7.7 BORING COMPLETED: 5 25 765 25 2:08 8.8 7.6 TERMINOLOGY ON THIS LOG CREW CHIEF:q R RIG: Rnmlh GEC JOB NO: 1083 VERTICAL SCALE: 1"=3' LOG OF BORING NO: 3 PROJECT: DEPTH,SURFACE ELEVATION:9� FIELD & LABORATORYTESTS ion � 3 FEET DESCRIPTION AND CLASSIFICATION GEOLOGY N WE SAMPLE TYPE REc. MC DEN I €.L. Qu 1 -_ 2 Not sampled to 7' 3- 4- 5- 7 __ CLAYEY SAND 900 with a little gravel, TILL 3TW gray, (Sc) 1300 1$ -----------END OF BORING.,_. ®- 10- 11 - 11- 12- 12 -131- 13- 14- 14- 15- 15- is- 15- 17- 17- Is- 17- 19- 19 -20- 20- 21- 21 -DEPTH DEPTHDRILLING METHOD WATER LEVEL MEASUREMENTS NOTE: REFER TO SAMPLED SAMPLED BASING CAVE-IN DRILLING WATER 0-`7 : HSA DATE TIME DEPTH DEPTH MUD LEVEL LEVEL THE ATTACHED SHEETS FOR AN EXPLANATION OF Not taken. BORT N G TERMINOLOGY COMPLETED: 5/25 76 ON THIS LOG CREW CHIEF: 8 • B RIG: Bomb C TEST BORING AND SAMPLING PROCEDURES STANDARD PENETRATION - SPLIT SPOON (ASTM D 1586) A 1-3/8" ID, 2" OD steel sampling tube is.driven into the soil with a 140 pound weight falling 30". The number of hammer blows required to drive the sampler 1', after an initial set of 1/2', is the standard penetration test ("N" value). The "N" value is an indication of the strength and compressibility of soil. Split spoon samples normally are taken at intervals of 22' or 5'. At 22' intervals, the depth to contacts between soil layers can be determined to an accuracy of about 1'. At 5' intervals, the depth to contacts between soil layers is determined approximately, and the type of material present between sampling intervals is inferred based on the action of drilling tools. The bore hole is advanced between sampling intervals with a plugged, hollow stem auger, with casing, or by jetting. To prevent caving, the bore hole is kept open by means of hollow stem auger, casing or drilling mud. AUGER BORINGS An auger is drilled into the soil. The auger is then spun or retracted, and samples are taken at the ground surface or off the auger. Using this method, determination of the depth to contacts between layers normally is approximate only. THIN WALL TUBE SAMPLES (ASTM D 1587) Comparatively undisturbed samples are taken with thin wall tubes which are pushed hydraulically into soil. STATIC CONE TESTS The static cone test entails measuring the force required to push a steel cone penetrometer into soil. The.cone diameter is 24" and the apex angle is 60'. The cone is pushed hydraulically at a rate of 1" per second. The static cone bearing pressure, qc, is the total load divided by the projected end area of the cone. The static cone bearing pressure is an indication of the strength and compressibility of soil. CORING (ASTM D 2113) Coring is done with a. diamond or carbide bit on a double tubed barrel. Geotechnical Engineering Corporation TERMINOLOGY ON BORING LOGS DRILLING, SAMPLING, AND TESTING A,B,N: A, B or N size casing or core. AC: At completion of boring. 4 cas: 4" inside diameter casing. CONS: One dimensional consolidation test. DEN: Dry density, pounds/cubic ft. FA: 6" diameter flite auger, motor driven. HYD: Hydrometer grain size analysis test. HA: Hand auger. HSA: 34" inside diameter hollow stem auger. JW: Jet with water. JDM: Jet with drilling mud. LL: Liquid limit. MC: Moisture content, percent of dry weight. N: Standard penetration test, penetration resistance, or N value, blows/ft. ORG: Organic content, percent. PERC Percolation rate, minutes per inch. PERM: Permeability test. PL: Plastic limit. qc: Static cone bearing pressure, tons/sq. ft. Qu: Unconfined compressive strength, tons/sq. ft. REC: In split spoon sampling, the length of sample recovered, in inches. In rock coring, the length of core recovered as a percentage of the total core run. SA: Sieve analysis test. SG: Specific gravity. SL: Shrinkage limit. SS: Standard Split Spoon Sampler. Steel, 1-3/8" inside diameter, 2" outside diameter. 2 TW: 2" diameter thin wall tube sampler. 3 TW: 3" diameter thin wall tube sampler. Wash: Cuttings returned from jetting. WB: Describes whether the sample appears to be waterbearing. (See attached sheet for additional information.) WH: Sampler advanced by static weight of drill rod & 140 lb. hammer. WR: Sampler advanced by static weight of AW size drill rod. -200: Amount of material finer than #200 sieve, percent. : Water level symbol. (See attached sheet for additional information.) Q9otechn1i ng Corporation TERMINOLOGY ON BORING LOGS GROUND WATER The level of ground water in a boring is indicated by the water level symbol (® ), in the WB column. The purpose of the water level symbol is: first, to indicate that ground water or saturated soil was present in the boring, and secondly, to indicate the apparent upper level of the ground water. Absence of the water level symbol does not necessarily mean that ground water was not encountered, or that the water table or piezometric surface was not penetrated. The water level symbol with an arrow pointed downward indicates that the water level is at or below the level indicated. Conversely, the water level symbol with an.arrow pointing upward indicates that the water level is at or above the level indicated. The water level symbol can represent various ground water conditions. These include: a "normal" condition, in which all of the soil below the water table appears to be saturated; a "perched" condition; an artesian condition; and layers of waterbearing sandy soil contained within clayey soil. Determination of the ground water level is often an interpretive process. The determination is based on various factors, including water level measurements, the appearance of samples, overall subsurface conditions, and site conditions. Consequently, the indicated depth of the ground water level may be quite accurate, or it may be only an approximation. The presence of ground water and the level of the water table change with time. The information in the WB column is based on observations and measurements made at the time the boring was drilled and water level measurements were taken. This information could be different at other times. Other notation in the WB column describes whether soil samples appear to be waterbearing or saturated. Y means yes, N means no, and ? means questionable, marginal or indefinite. Road TERMINOLOGY ON BORING LOGS GEOLOGY The geologic description in the column "GEOLOGY", indicates the apparent depositional origin or stratigraphic name of the material. The general categories of geologic deposits are: BEDROCK Normally dense, consolidated rock. Can also be soft, compressible and non-cemented. COARSE Sandy (and gravelly) soil. Stratified. Deposited ALLUVIUM from fast moving waters in streams, rivers and deltas. FILL Formed or deposited by man. FINE Clayey and silty soil. Stratified. Deposited from ALLUVIUM slow moving waters in streams, rivers, and lakes. LAKE Clayey soil. Laminated. Deposited from'very slow DEPOSIT moving waters in ponds and lakes. LOESS Silty soil. Non -stratified. Upper layer. Deposited from wind. OUTWASH Coarse alluvium deposited from glacial meltwaters. SLOPE Organic and inorganic material washed from slopes WASH and deposited in depressions. SWAMP Peat, muck, and marl. Formed principally through DEPOSIT deposition and accumulation of organic material. TILL Non -stratified. Often contains a wide range of grain sizes, from clay through boulders. Deposited directly from glaciers. TOPSOIL Upper, black layer of soil. Contains both inorganic and organic material. Formed by weathering and organic accumulation. TUMBLEROCK Dominantly gravel, boulders and rock slabs deposited from gravity flow dowan hills or cliffs. WEATHERED Bedrock undergoing substantial weathering through BEDROCK disintegration or decomposition. WEATHERED Inorganic. Texture is transitional between topsoil SOIL and underlying non -weathered soil. Geotechnical Engineering Corporation v �. #2 g #1 Proposed 351 House m GEC #1083 11 _--South Property Line scale: 1" = 20' Geotechnical Engineering Corporation -P O �4 -P En IC: 4J 9 44 0 RM � fu 4 26' 43 �. #2 g #1 Proposed 351 House m GEC #1083 11 _--South Property Line scale: 1" = 20' Geotechnical Engineering Corporation -P O �4 -P En IC: 4J 9 44 0 RM City of Fridley SUBJECT P - - ®1358'7 AT THE TOP OF THE TWINS PERMIT r t ` BUILDING R IPT NO. `L______ COMMUNITY DEVELOPMENT DIV. PROTECTIVE INSPECTION SEC. ", 'Frio " s, r--'1CITY HALL FRIDLEY 55432 NUMBER REV. DATE PAGE OF APPROVED BY 612-580-3450 910-F15 6/14/76 JOB ADDRESS 8100 Ruth Street N.E. 1 LEGAL LOT NO. BLOCK TRACTOR ADDITION SEE ATTACHED DESCR. 4 3 Bourdeau's Spring Brook Addition SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE The Rottlund Company, Inc. P.O. Box 32082 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 6 USE OF BUILDING Residential 7 CLASS OF WORK Ij NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE Asa nags&@ Am 8 DESCRIBE WORK VvAgrilfiv Construct.a 48" x 2716" Dwelling and a 24' x 24' Garage 4211 Before Wng IOC21 TELEPHONE - ELECTRIC - GAS 9 CHANGE OF USE FROM EQ ,IRE(` {iii w BY LW REQUIRED HEATING, PLUMBING AND SIGNS. STIPULATIONS Provide a hard surface driveway. Provide sod in - the front and side yards Provide a verifying survey before capping. Provide soil borings and compaction tests. Provide City with copy of truss design. SEWER SERVICE (Approx. 14' Deep) 160' South of Manhole (Inv. 841.49) WYE ELEV: 842.18 TOP OF FOOTING: 845 WATER LCOATION: MUST BE TAPPED. 6" CIP 15' East of east property line. Assessing has record of water service but as-builts don't show water extended. TIME 'CITY Of FNDW DOES NOT GUARANTEE THE '--IMPORTANT— ACCURACY OF UTILITY LOCATIONS AND ELEVATIONS. NOTIFY THE �RfDl.l+Y ENI RIDLEY TT"15 DATA IS FOR INFORMATION PURPOSES ONLY ANI L?1V1Slt"N ��I C: CU CURB PERSONS USING 9 SHOULD VERIFY TIME INFORMATIO14 FtDIVIE lei. AVL( REPLACEMENT ON THE 51T1:. AT V;;.'vL-WAY OPENINGS, SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SQ. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT 3 -I- 576 25,999 + 5760 ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT`I HAVE READ AND EXAMINED THIS APPLICATION 71 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED. WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT $39,890 $19.95 DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- STRUCTION OR THE PERF44RMA E OF CONSTRUCTION. $58.75 $350.00 e®p-hp aerf ; PLAN CHECK FEE TOTAL FEE --%- / 'ev-0-2, b - / I - $428.70 SIGNA 'O E OF CONTRACTOA OR AuTfIORIZEDAGENT (DATE) WHEN -PROPERLY VALIDATED THIS IS YFUR PERMIT G Ir BLDG INSP DATE` SIGNATURE OF OWNER (IF OWNER BUILDER) (DATE) APPLICATION FOR RLSIIENTIAL, ALTERATION! OR ADDITION BUILDING PERMIT CITY OF FRIDLEY, MINNESOTA OWNER'S NAME : ,QA, ( Q.7f yY BUILDER: 2/24,-, ' F o. yj.- ADDRESS • ADDRES S:—P- 110: :P N0: �r:? 0 0 STREET: ��' RI. LOT: BLOCK: ADDITION: !3 c CORNER LOT: INS IDE. LOT: SETBACK: SIDE YARD: ) � ' Applicant attach to this form Two Certificates of Survey of Lot and proposed building location drawn on these Certificates. DESCRIPTION OF BUILDING To Be Used AS: 91A/9%e, FAPA .f y <� Front: S' __Depth: `� �, " Height: Square Feet: ---/,3_Q-6 Cubic Feet: Front: 2!j Depth: J_ q ' Height: Square Feet; `) Cubic Feet: Type of Construction: A ov„e_ Estimated Cost: To Be Completed: © ;—) t `�? J ° ° ® 64F ® s The undersigned hereby makes application for a permit for the work herein specified, agreeing to do all work in strict accordance with the City of Fridley Ordinances and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct. DATE: o o - -7 L. SIGNATURE:_ (See Reverse Side For Additional Information.) ENGiN_"F---_;'H%!G 11VIC LEFNGIM�ERS 0; LAND SURVEYORS' -- 900'. BURNSVILLE.. .MINNESOTA Certlflcate of Survey.F -o r. c— 17 N y 5( % 1bF W. :!s Q_ tt L 115. 0 7 EAST 104 DRAIHAGEt4- U i 10TY, -o INDICATE 5 IRON T. Al E . ---ALU.- BEARINGS -DE5CRIPTION I hereby certify that this survey, plan or report was prepared by me or under my direct LOT -4 1 'BLO.CK :3 supervision and that I am a duly *rkt-gistered 30WRDEAV)('5Surveyor Land SPRING 131RCOK ADDITION or under the laws of the ,. ' La1; , of Minnesota. A NQKA -CO. U N TY MAIES07-A-1- -n M_- Reg. No 'o I a, 0 f- /)f. #, CZv looeolds?,- f__p r ,,t ��SiS5er7Cr I �a(" hws k;-7c,:�);cr /foo, Air) �vr,v9 0 O/, I �et> GP I eell%c �--- bai e,0--le0/4 TS qoi ti� �ffo�v (k CITY OF FRIDLEY APPLICATION FOR PLUMBING AND GAS FITTING PERMIT Job Address 4' /100 X''9•/4 '57 Ire - Department of Buildings City of Fridley Tel. #571-3450 The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the City Codes and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct Fridley, Mn. 1976 OWNER CI -M-5 KIND OF BUILDING/.t AQP USED AS Z&- TO & TO BE COMPLETED ABOUT PARTIAL RATE SCHEDULE m ESTIMA D COST PLUMBING FIXTURE RATES: m RATE rt OLD NEW ILDING PERMIT NO. v Number Fixtures X N $ Water m o m u r. •ca N A $ &-Z) Company w w x $2.00 Heater v .0 Iq x N $' E •I cd W _� x m ro W 100,000 BTU to 199,000 BTU x $10.00 $ Water Softener .N $7.00 $ New Ground Run Old Building x $5.00 $ ROUGH INSP. it N O •rzi Electric Water Heater x $5.00 N 1 O O � N4.) to N N M .0 Date o w x in $ o w vci w/ v w 3 $ 0 o a/s lec to 3: Uro Gas Range to 199,000 BTU x $10.00 $ 1st 2nd 3rd 4th (R) = Future Connection Opening Connected with Sewer () = New Fixture, Old Opening Wates Job Address 4' /100 X''9•/4 '57 Ire - Department of Buildings City of Fridley Tel. #571-3450 The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the City Codes and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct Fridley, Mn. 1976 OWNER CI -M-5 KIND OF BUILDING/.t AQP USED AS Z&- TO & TO BE COMPLETED ABOUT PARTIAL RATE SCHEDULE ESTIMA D COST PLUMBING FIXTURE RATES: NO. RATE TOTAL OLD NEW ILDING PERMIT NO. PERMIT NO. Number Fixtures x $3.00 $ c3 e0 CsY PGF Future Fixture Opening y x $2.00 $ &-Z) Company New Fixture, Old Opening x $2.00 $ Signed By Catch Basin x $5.00 $' Tel. No. / /� 30 y �+��' lJ Water Heater - to 99,000 BTU _� x $5.00 $ 100,000 BTU to 199,000 BTU x $10.00 $ Water Softener x $7.00 $ New Ground Run Old Building x $5.00 $ ROUGH INSP. Date Electric Water Heater x $5.00 $ GAS FITTING FEES: FINAL INSP. 7 (� Date 1st 3 fixtures x $3.00 $ Additional Fixtures x $1.00 $ APPROVAL FOR PERMIT Gas Range to 199,000 BTU x $10.00 $ REPAIRS & ALTERATIONS First $100.00 $5.00 $ each add. $100.00 or fraction $2.00 $ --r MINIMUM FEE FOR ANY PLUMBING PERMIT IS $7.50 State Surcharge $ .50 ,1 TOTAL FEE $ REINSPECTION FEE ($10.00) r y ti -7 5-0 CITY OF FRIDLEY APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES PARTIAL RATE SCHEDULE GRAVITY WARM AIR: RATE TOTAL Furnace Shell & Duct Work $12.00 $ Replacement of Furnace 7.00 $ Repairs & Alterations -up to $500.00 7.00 $ Repairs & Alterations each add. $500.00 4.00 $ MECHANICAL WARM AIR: Furnace Shell & Duct Work to 100,000 BTU $12.00 $ % 1__,00 each add. 50,000 BTU 4.00 $ Xy 0a Replacement of Furnace 7.00 $ Repairs & Alterations -up to $500.00 7.00 $ Repairs & Alterations each add. $500.00 4.00 $ STEAM OR HOT WATER SYSTEM: Boiler & Lines up to 100,000 BTU $12.00 $ each addn. 50,000 BTU 4.00 $ Boiler only up to 100,000 BTU 7.00 $ each addn. 50,000 BTU 6.00 $ OIL BURNER- to 3 gal. per hour $10.00 $ each add. 3 gal. per hour 10.00 $ GAS BURNER- from 100,000 BTU to 199,999 BTU $10.00 $ (over 199,999 BTU see Fee Schedule) $ GAS FITTING FEES: a 1st 3 Fixtures _� x $ 3.00 $ Additional Fixtures x $ 1.00 $ Gas Range to 199,000 BTU x $10.00 $ AIR CONDITIONING FAN HEATING SYSTEMS � See Fee Schedule $ VENTILATING SYSTEMS $ ALTERATIONS & REPAIRS $ State Surcharge $ .50 TOTAL FEE $ "3 IF, S'o ROUGH INSP. REINSPECTION FEE Date C$10.00) FINAL INSP. - - Date �( APPROVAL FOR PERMITf�' MINIMUM FEE FOR ANY HEATING PERMIT IS $7.50 Job Address O /O 0 %Z " /--Z .S - Department of Buildings City of Fridley Tel. #571-3450 The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the City Codes and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct. 7 Fridley, Minn. % "e- °, , 19 A � OWNER /� KIND OF BUILDING -A O/;P - USED AS � cies/1/ i% TO BE COMPLETED ABOUT% - ESTIMATED COST - Z k 6 S o 0 OLD BUILDING PERMIT NO. PERMIT NO. _ DESCRIPTION OF FURNACE/BURNER HEATING or POWER PLANTS, Steam, Hot Water,zul Ai No.' Trade Name Yn er . d Size No. C tv /0j- Capacity 0S-Capacity Sq. Ft. EDR /G`J_nu.)BTU HP _ Total Connected Load 5 L Kind of Fuel �� l BURNER - Trade Name Size No. Capacity Sq. Ft. EDR BTU HP G10. p tt Company �7Eo. SEOG�h'st��K e pFRgned By VL.iS i 1001 XENIA AA,-. -r? r r IMINNEAPOLIS, ,N Tel. No. 545 I 1 ° CULATI&S HEATING& AIR CONDITIONING CO. MINNEAPOLIS, MINN Weatherstrips A.S.H.V.E, Construction No. Insulation Guide W i ndows Dors out. Wa I I int. Wall Ceiling Roof Floor Kind HoarApplied Reference T- Yes—No Yes—No 19 1.,4 / .ZIA ,_Room Length 17 Width I 5� Height F1. 6- Room I Learh 09 ;?- Width/,? Height Windows and Doors—Crackage and Area Windows and Doors—Crackage and Area 4, dth Height No. of Lineal f'. Area �ro"3 ne of P. N v � f j;'ack pane lights 0 so. fr. 3 0. ,4 1 No. �e,gnt N eal Are 11 g4l'. of crack sq. a 21- o'! ra ft. _Z4 Coef j Btu Coef j Btu Infiltration Infiltration CY 1_9 V61 Glass 34 L�6r 2;( 110 Glass z e—C -0 Exp. wa I I 47� Exp. wa I I., Net exp. wall INet 3 exp. wall Int. wall Z) (n Int. wall Ceiling 1"'71 Ceiling Floor Floor Total Btu. Total Btu. 41, Required sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. ft. E.D.R. or sq. ins. W.A. Leader area DOM I Length Width// Height z Fl.,oc-0 Room I Length Width Height Windows and Doors—Crackage and Area Windows and Doors—Crackage and Area No. Width Height No. of Lineal ft. Area of pane of pane lights of crack sq. ft. Width Height No. of Lineal ft. Area of P-vm of pa nn lights of crack sq. ft. /Z Coef Btu Coef Btu Infiltration Infiltration W A Glass 7. 10 S—,o Glass Exp. wall Exp. wa I I Net exp. wall Net exp- wall Int. wall Int. wall Ceiling bazzl- /9/r /a I elf C) Ceiling 7 Z Floor v Floor 'X Total Btu. Total St.. Required sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. ft. E.D.R. or sq. ins. W.A. Leader area If FI Room Length Width 6- Height FI. Room Length Z Width Height 0-5 _001 I Windows and Doors—Crackage and Area Windows Windows and Doors—Crackage and Area Height No. of Lineal ft. No. of I of pane f pang ie lights of crack Area sq. ft. No. Width Height No. of Lineal cracf. of pane of pane lights of k Area sq. ft. Coef l Btu Coef Btu Infiltration , Infiltration V Glass"� 4 Glass Exp. wall j Exp. wall Net exp. wall 14-7 I/V !i I V Net exp. wall I - Int. wall Int. wall Ceiling�( ov Ceiling J Floor Floor Total Btu. 9P 1� Total Btu. Required sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. ft. E.D.R. or sq. ins. W.A. Leader area MINNEAPOLIS, M WIN. :-CALCULATIONS HEATING&AIR CONDITIONING CO. Weatherstrips A. S. H. V. E. Guide Reference 19 Construction No. Insulation W, ndows DcKffs Out. Wall Int. Wall Ceiling Roof Fl" Kind How Applied Yes—No f Yes No I I z [F I - �4 60 7r WHeight Length �dth Z 2 -eight F1 He i grit Windows and Doors—Crackage and Area Height N1. No. ' hof Linea! ft. P3,4- n, lights of crack. sq, VP Windows and Doors—Crackage and Area W, & 4e" Nc,, L+neai It. Area N.C. q hi of pane i c I ,ane gl,,- sq. ft. of C,ack --7Co­ef Btu ICoef! Btu Infiltration -7r Infiltration --7 6— 7 Glass to) Glass 4 Exp. wa I Exp. wal I o, -P 7,r 711 Net exp. wall 1 0 Net exp. wall lht. wail Ceiling M Z017= Int. wall Ceiling Floor Zig L Floor J 31 Tota I Btu. Tota I Btu. �z 7 00 Required sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. ft. E.D.R. or sq. ins. W.A. Leader area ,,�,/,-eoom I Length /,;?—Width Height AFFI,01:�kir Room Length Width _3 Height Windows and Doors—Crackage and Area No. Width Height No. of Lineal ft. Area of pane of pane lights of crack_ sq. ft. '93 73 — Windows and Doors—Crackage and Area No. Width Height No. of Lineal ft. Area of pane, of ,,) h I an lights of crack sq ft. E Coefj Btu jCoefj Btu Infiltration Infiltration GlassI 74-C Glass -3 tIZ7 /9--5,v Exp. wall 916 Exp. wa I I Net exp. wail Net exp. wall Int. wall Int. wall Ceiling Ceiling Ir Floor Floor 51 Total Btu, o, Total Btu. Required sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. ft. E.D.R. or sq. ins. W.A. Leader area v We Fl. Room I Length Width Height Fl. Room i Length Width Height Windows and Doors—Crackage and Area Windows and Doors—Crackage and Area N, Height � No. f Lineal f,- Area f ane C ofanlights of crack No. 3f Lineal Area Width Height ft. No. pane of pane hols of crack sq. ft. of :4oefi Btu i Coef Btu Infiltration d Infiltration Glass Glass Exp.,' e11 i Exp. wall Net exp. wa I I Int. wall Ceiling Floor Ne I j I II Total eller area • 53-84-9915051 CRY Of Fridl0y ' ' ��rr.•1 Application for �'lurt'�=3 i 6 6 6 6 • Dop't. of Bldg%. phone M-3450 DESCRIPTION 0: V1011> d8100 °tzth atreet NE Numbs:. 1:' azd L cNion of Fixtures ' City of Tridley: _ � 7 < 7 . e s N w�Tt� writ. t:�s cuG The undersigned hereby smokes appl cat'on for a permit for the, cork H wlth tt:e Cit,T O:�:t o ii M s . `. : o (� j 3 fi u u • (u specified, a� ening to do all work is strict acco:darce hereby declares Lhat s:I t.`:e is N and ruling of the D�;parttrent of nuild.'ngr, and are true zrd rorT�"t' 8sca • , and represertatlons stated 1n . Is appllcatson , 8-30-76 co nec r n , iYidley, Man ?nd I Owner ROTTL COMP 3:d —' - Kind of Building t:•y - Ccrrtt::.d witz . • FL :::o Ge:.:z:::: CT•c:r.�. uoasr (] U5ad as s ?{av Flx:un. Old 074aings Cc:rpcol C] 9-h-7 � r®'ams-"-•'ate- To be completed about • 10.00 Estim.3ted Coat, S PARTIAL RATE SCHEDULE p•t�=t :,,• - Old--Now. Building Permit Lr~+18ING rjXTU?E RATES: NO. RATE TOTAL Sinned x $2.00• S NumberFixturrs :............... �.�..--- By— Future Fixture Opening 6 • . • • ••• • • • • •---- • X 51.50 S "-- Busins Phone N ��., New Fixture Old Opining 6 0�0 6 ••' • • • • ------ x S 1.50 i ..--» -•-- • Catch Bilin 0 . 6 ... 6 . . 0 .. 6 6 0 6 0 6 .. .®�.. x $3.25 = ' • ' `Fater Neater 11:0 to W.000 BTUs • 6 • • ------ x S.3 S � NOUGH • New Ground Run 016 Bidr.:..:.... ----- x %,, S 00 S . Eiectt:.c Y.a:er Y.sw... • .........�.�...�... a •-• $2 FINnL .. 1AS 3'iT 611 G FEES: NO. WITZ TOTAL ' • 1st3Fixtures ••••a••••••°'•"" x $2.00 ' Ad41tlanal Fixtures ............... ---•-- x $ .75 S . Gs R.S +e to 159,000 BTU 6....... 6 .• x $5.00 ....... , .50- State Surcha:9a ' XL`a =RATI0XS—P.sfer to Cods _ .1kzCrl'ytfon..ease. safe .66.i6666..6..a.6....r..... ' - - 5.50 • • TOTAL f'L2d n t$. - • 1 rJAN unroF FRIDLEY FRIDLEY MUNICIPAL CENTER • 6431 UNIVERSITY AVE. N.E. FRIDLEY, MN 55432 • (612) 571-3450 • FAX (612) 571-1287 WEED NOTICE August 20, 1991 Michael Melby 8100 Ruth Street N.E. Fridley, MN 55432 RE: Noncompliance of Fridley City Code 105 (Weeds) at the Following Property: Location: 8100 Ruth Street N.E. Legal Description: Lot 4, Block 3, Bourdeaux's Spring Brook Addition Property I.D. No.: 03-30-24-24-0041 Dear Mr. Melby: Fridley City Code 105 (copy enclosed) states that it is unlawful to maintain land in the City upon which weeds, grass, or rank vegetation exceeds ten (10) inches in height; or other noxious growth exists as outlined in the ordinance. This was enacted to protect the health and safety of the community and its residents. A recent inspection of the above referenced property revealed conditions which are not in compliance with this ordinance. It is important that you take appropriate steps to correct this situation immediately. I will conduct a reinspection on or shortly after September 3, 1991, at which time full compliance is expected. Should this deficiency still exist, I will instruct the City's Public Works Department to abate the condition. In the event the City abates the condition, you will be served a notice in writing indicating the work performed and the costs and expenses involved. The total amount must be paid to the City within 30 days after this notice or before the following October 1, whichever is later. If this is not done, the costs and expenses shall become a lien in favor of the City; and a 150 penalty will be added to the amount due as of the date, with the total costs, expenses, and penalty thereupon to be certified to the County Auditor for entry on the tax books as tax against the land. Please call me at 572-3595 if you have questions or wish to discuss this further. Thank you for your cooperation! Sincerely, Steven Barg Weed Inspector CE -91-362 i dry Z�- Ct-AM"AlOe %L 4.4,JXCVOL4�� AAA� wry b.o . STEVE BARG I happened to stop by and talk to the lady at 8066 Ruth Drive and she showed me her waste pile in the back. The pile has been substantially reduced, its only about 2'/2 to 3 feet high and she is working on it 4nd will continue working on it. In talking to the neighbor, it is a lot better then it use to be. I noticed behind that Pet Food Warehouse off of Commerce Lane, their fence is falling down and the posts are laying all over the back of the property. Since it is so visible from the right-of-way you may want to check with them on cleaning up their back yard. I noticed that the Hanna Car Wash property on 73rd and University, there is a weed problem. I don't know who owns it anymore but we should try and get that lot cleaned up. June 5, 1992 ADDRESS FILE Property at 8100 Ruth Drive. I visited the back of the property to investigate the railroad tie retaining wall behind the house on Springbrook Creek. The house has a total of three tiers of railroad tie walls. The bottom wall along the creek has experienced considerable erosion and it starting to lean, rot and fail. I suggested to the property owner, Mr. Melby, home phone 780-2815, that he work with the property owner to the north and submit a request to the City with a sketch indicating what they propose to do and approximate cost for City participation in a storm water project. Based upon the lack of horizontal distance behind the homes, it would appear that rip rap will not work but one or two batches of gabions on the lower section with filter fabric, would prevent any further erosion and also secure the toe of the hill that backs up to the house. SUBJECT PER 2 4f t77 2 Cit�of Fr Fridley > ETWINS BUILDING PERMIT R NO. i COMMUNITY DEVELOPMENT DIV. 1 1 PROTECTIVE INSPECTION SEC. ��Tyy Ci� 1 � NUMBERREV DATE PAGE OF APPROVED BY t CITY HALL FRIDLEY 55432 j 612-571-3450 910-F15 7/18/96 JOB ADDRESS 8100 Ruth Street NE 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 4 3 Bourdeaux's Spring Brook SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Stock Roofing Inc 289 Liberty St NE, Fridley, MN 55432 780-3561 3112 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 6 USE OF BUILDING Residential 7 CLASS OF WORK ❑ NEW ❑ ADDITION ❑ ALTERATION REPAIR ❑ MOVE ❑ REMOVE 8 DESCRIBE WORK Reroof House & Garage (26 Sq) Tear -off 9 CHANGE OF USE FROM TO STIPULATIONS Underlayment must comply with the State Building Code. TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $2,000 $1.00 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- $62.25 ire SC $2.00 STRUCTION OR THE PERFO MANCE OF CONSTRUCTION PLAN CHECK F O AL FEE L n SC .00 $70.25 SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT IDATEI N LY V 1 ED THIS IS YOUR PERMIT SIGNATURE OF OWNER 0F OWNER BUILDER) IDATEI LOG IN MATE NEW [ ] Effective 3/1/96 ADDN [ ] CITY OF FRIDLEY ALTER [ ] SINGLE FAMILY AND DUPLEXES R-1 AND R-2 Building Permit Application ConstructionAd r ss. d e Legal Description: Owner Name & Address: Tel. # Contractor: Jr�� %���i - G " MN LICENSE # 3 Address: �r �,�i ��ic�l y Tel. # Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF IMPROVEMENT LAVING AREA: Length Width Height Sq. Ft. GARAGE AREA: Length Width Height Sq. Ft. DECK AREA: Length Width Hgt/Ground Sq. Ft. OTHER: Corner Lot [ ] Inside Lot [ ] Type of Construction: Approx. Completion Date: Ft. Yd Setback Side Yard Setbacks Estimated Cost: $ �� o 4&( ry , Ob Driveway Curb Cut Width Needed: _ DATE: 7-16 —�6 APPLICANT: Permit Fee Fire Surcharge State Surcharge SAC Charge License Surcharge Driveway Escrow Erosion Control Park Fee Sewer Main Charge TOTAL STIPULATIONS: $ 252-; (Cost: on Back) Ft. + 6 !Ft = t x $ CITY USE ONLY Fee Schedule on Reverse Side =$ 0 Tel. #_,7,y0 —3S� .001 of Permit Valuation (1/10th%) $.50/$1,000 Valuation $900 per SAC Unit $5.00 (State Licensed Residential Contractors) Alt. "A" or Alt. "B" Above $450.00 Conservation Plan Review Fee Determined by Engineering Agreement Necessary [ ] Not Necessary [ ]