Loading...
2015-01644Page 1 Residential Heat Loss and Heat Gain Calculation 9/17/2015 In accordance with ACCA Manual J Report Prepared By: �e ✓ ®� �� 4� Elk River Heating & Air Conditioning, Inc. An affiliate of.- Twin f:Twin Peaks Heating and Capstone Homes For: 437 Longfellow mks, MN Design Conditions: Minneapolis/St Paul Indoor: Outdoor: Summer temperature: 70 Summer temperature: 92 Winter temperature: 72 Winter temperature: -20 Relative humidity: 55 Summer grains of moisture: 98 Daily temperature range.Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 15,430 2,199 17,629 34,644 (1.5 tons ) Basement 2,408 242 2,650 8,281 Bedroom 1,271 114 1,385 2,457 Living Room 954 85 1,039 3,709 Bathroom 183 43 226 1,154 Laundry 0 0 0 961 Main Floor 13,020 1,958 14,978 26,362 Bedroom 1,167 114 1,281 3,437 Bedroom (2) 877 114 991 2,346 Living Room 5,242 1,275 6,517 7,258 Kitchen 2,463 341 2,804 6,658 Bathroom 104 0 104 461 Bedroom (3) 1,649 114 1,763 3,166 All Rooms 1,518 0 1,518 3,036 Whole House 15,430 2,199 17,629 34,644 (1.5 tons ) HVAC -Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load cal ulatfons are estimates only, actual loads may vary due to weather and construction differences.