Loading...
PRE 2010 DOCSSUBJECT PERMIT NO. City of Fridley ®15091 AT THE TOP OF THE TWINS BUILDING PERMIT r RECEIPT NO. • COMMUNITY DEVELOPMENT DIV. { PROTECTIVE INSPECTION SEC. 1 . � CITY HALL FRIDLEY 55432 NUMBER REV. DATE PAGE OF APPR VED BY 612-660-3450 910-F15 3/27/79 JOB ADDRESS 5627 West Bavarian Pass. N.E. 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 1 18 Innsbruck Villages SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Darrel A. Farr Development Corp. 7286 - 72nd Lane North, Npls. 560-8110 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 6 USE OF BUILDING Residential 7 CLASS OF WORK NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 8 DESCRIBE WORK Construct a 24' x 34' Townhouse and a 23' x 20' Garage 9 CHANGE OF USE FROM TO STIPULATIONS TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, Wood Frame VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT. CU. FT. AUTHORIZED IS NOT. COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION 22,936 Total OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $30,375 $15.19 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMITFEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- $91.74 $425.00 STRUCTION OR THE PERFORMANCE OF CONSTRUCTION. PLAN CHECK FEE TOTAL FEE $22.94 $554.87 SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT (DATE) WHEN PROPERLY VALIDATED THIS IS YOUR PERMIT ` BLDG INSP DAT SIGNATURE OF OWNER IIF OWNER BUILDER) (DATE) Alli,u (;AT I ON. 1:01Z R).:S1 DJ:N' CJAJ,, AL'1'EAZA.1'ION ) OR ADWTION BUILIJTI G 111:1z;•IIT CITY OI" 1:RJDI.1:Y, .Sli\:\'1113.) r1 0,::�EI;�S NI�I.1I::�Ai',�►N��J+. ,�e���- TSI, ��}��s3;uILDRR: •�L�t*t� A1L� �AD��.�ss:T'! : x/15. SIN. -70 .9410 LOT: / BLOCK • /JP ADDITION • ramm A rU e I CORINER LOT: INSIDE LOT:- SETBACK:* SI DEY/ D : Applicant attach to this form Two Certificates of Survey of Lot and proposed building location drawn on these Certificates. DESCRIPTION OF BUILDING To .Be Used As: mama amse- Front: wal- Depth: Height : 2 0. Square'Feet: /7493 Cubic Feet: Front: 6 —Depth: Height: to Square. Feet;_410 Cubic Feet: Type of Construction: WDoct Tntme, Estimated Cost: $ ToCompleted: d • T Beb� C � ! to % % The undersigned hereby makes application for a permit for the work herein specified, agreeing to do all work in strict accordance with the City of Fridley Ordinances and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application. are true and correct. d7 DATE: (See Reverse Side For Additional Information.) fieftA6 a V. Cie. 0)4, P.c, A-1.44 17 s.� ,a- 4 -1®y-7 CITY OF FRIDLEY APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES PARTIAL RATE SCHEDULE GRAVITY WARM AIR: Furnace Shell & Duct Work * Replacenent of Furnace Repairs & Alterations-gp to $500.00 Repairs & Alterations each add. $500.00 MECHANICAL WARM AIR: Furnace Shell & Duct Work to 100,000 BTU each add. 50,000 BTU *Replacement of Furnace Rapairs & Alterations -up to $500.00 Repairs & Alterations each add. $500,00 STIAb, OR HOT WATER SYSTEM: Boiler & Lines up to 100,000 BTU each addn. 50,000 BTU Boiler only up to 100,000 BTU each addn. 50,000 BTU OII*BURNER- to 3 gal. per hour each add. 3 gal. per hour RATE TOTAL ,lob Address tr4 d % $12,00 7.00 7.00 S Department of Bgijdings 4.00 City of Fridley Tel. #571-3450 The undersigned hereby makes application for a permit for the work herein $12.00 $.� specified agreeing to do all work in strict accordance with the City Codes 4.00 $ and rulings of the Department of Buildings, and hereby declares that all the 7.00 $ facts and representations stated in this application are true and correct. 7.00 $ 4.00 yO Fridley, Minn. , 19 Ot MER &4A4696 `4192 0+� $12.00 4.00 7.Oq 0 -pp S;q-qA TA. PQ GASy BURNER- from 100,000 BTU '�o 1qq, j9q ATN S}.A• AG (over 199,999 BTU see Fee Sche4}}le� GAS FITTING FEES: 1st 3 Fixtures / x $ 3.Aq Additional Fixtures Gas Range to 199,000 BTU x s4A:AA AIR CONDITIO.yING s MrW-o1loi FAN HEATING SYSTEMS VENTILATING SYSTEMS See Fee Schedule ALTERATIONS $ REPAIRS State Surcharge ROUGH INSP. OO Date FINAL INSP. (� A6 -09". Date APPROVAL FOR PERMIT TOTAL FEE REINSPECTION FEE ($10.00) S S S $ /®.d® S �UD q /®.0 o $ 9 $ .50 $ is S® MINI:bIX FEE FOR ANY HEATING PERMIT IS $7.50 PLUS $.50 STATE SURCHARGE *Attached stack verification form Plip OF BUILDING PsEP AS TR pp� PQM?T`ETRA 3APQNT 71 FSTT:pR pESCP4PTTPIJ PF FURNACE/FUP-NER #.TTNr- Pr $QWP?t F? ITSt Stearn, #(Rt Waters WarA} A}r- No. Trade Name Size No. Capacity Sq., Ft. HDR BTU Ses P&P HP Total Connected Load v(rjr -17 `f Kind of Fuel Q__ BURNER - Trade Name '" Size No. a ®? A?.116- X5, Capacity Sq. Ft. EDR BTU HP Company Signed By Tel. No. - jog �'7 PP Windows Doors Guide --"- ---- --' --r— - Reference Out. Wali Int. Wall Ceiling Roof Floor Kind How Applied Yes-No Yes -No 19 HEAT LOSS CALCULATIONS HEATMOA AIR CONDMONING CO. MINNEAPOLIS, MINN. Weatherstrips A.S.H.V•E. Construction; No. Insulation Windows Doors Guide --"- ---- --' --r— - Reference Out. Wali Int. Wall Ceiling Roof Floor Kind How Applied Yes-No Yes -No 19 I ---- _ _-- FI. a -C,. Room Length ,� Width 9 Height �/F Room I Length` Width a/ Height Windows and Doors-Crackage and Area ., t4tindows and Doors-Crackage and Area I No. Width Height _ of pane I of pane No. of Lineal ft. Area lights of crack sq. it. i d•h i H ight No. of No' rt pa nr-_-f of cane Irghts Linea. Area of rac. I sq. h. ----�- -- -- _It Coef! Btu ! r,rf� Btu Infiltration 'ra� In filtration --- -- --- ---1--- - I Glass °m / �, G lass _` i Exp. wal I_2011Exp. wal INet exp. wall --- ---- Net exp. wall - :. Int. wall ----_, Int. wall 1 Ceiling Ceiling ie f�� �j "--P Floor Floor — Total Btu. Total Btu. Required sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. It. E.D.R. or sq. Ins. W.A. Leader area 'g�Fl. �a;;� �> �• .Room Length lalWidth r„ Height j FI Room Length Width /O Height •.._ g IC.00f! Btu Windows and Doors-Crackage and Area Windows and Doors-Crackage and Area No. Width—� Height No. of Lineal ft. of pane of pane Ilghts of crack ,-- Area sq. ft, l'.rrr—_� Hr.�,nt N•.,, cf :�naa tt.� Area Ne%• I of pan'! 4phts cf ; rac' sq. ft. Coef B to Infiltration I _ ------ Glass ! - - i Infiltration I J Glass — --- - --+—._ --- Exp. ----------- � .—.__--G __---- -- --- 111 � __ — fwall dp c7_ Exp. wal l Net exp. wal I �! %/ et exp. r:a i _ Cb? i � ,si � -• -- - - - - Int. wall nt. a., Ceiling -- r•illna fal rte. ---- -- -- rV fG A Floor --- Tota! Btu. j a s T _ to s;u. ` • P� - Required sq ft. F.D.R. or sq. !ns. W.A. _=ader are, � � Re.; . r.r"i �.� ft. E.D.R. or sq I s. W.: -t. +.f a rr ,area Fl. Room 1 i en rh t+ Width H c ht --------------- i . F� f� ! f ngth Wirith Hei ht Windows and Doors- Coni kagta and Area i No. Width—T N1 qht f ` t... ;.� 4••-, t `Inric,vr and Doors Crackaye anti Area - .' ti_ ._•V rT-I r.t Aired I ..^� I )VVof pane T lights , k 4 ri. o*"'', _'— _ _lt .i-- f : r c —4- - -- - r L Coef--- --i i B t 1 -_�� • .` ti �- Infiltration I Glass I Ir,f; rat,nn i Class f - Exp. wall Exp. waif Net exp. wall ;J1. kill I Int. wall 1 I -- --- - � tnt• -- Ceiling- -- — — }}'}-----i ---- '�-� wall I - --'_----- - _ Cr i.l rg_.-_. F l oor ; F I ocr -- f Total Btu Required sq. ft. E.D.R. or sq. ins. W.A. Leader area, Total Btu. Required sq. ft. E.D.R. or so. fns. W.A. Leader area ti �f A-41 CITY OF FRIDLEY 6431 UNIVERSITY AVENUE N.E., FRIDLEY, MINNESOTA 56432 TELEPHONE ( 612)571-3450 December 26, 1979 Darrel A. Farr Development Corp. 7286 - 72nd Lane North Brooklyn Center, MN 55428 Re: Final Inspections at 5616 West Bavarian Pass N.E. & 5627 West Bavarian Pass N.E. Dear. Sirs: Final inspections were made on December 20, 1979 of the above addresses and the following items were noted which must be completed before the structures can be finaled out; 5616 West Bavarian.Pass N.E. 1. Provide sod in the front and side yards by June 15, 1980. 2. Provide handrail and guardrail on inside stairway by January 21, 1980. 3. Provide access door to plumbing -wall at bathtub by January 21, 1980. 5627 West Bavarian Pass N.E. Provide access door to plumbing -wall at bathtub by January 21, 1980. We will expect the above items to be completed by the scheduled dates when reinspections will be made to determine compliance. If you have any questions on these items, please contact me at 571-3450. Sincerely, DARREL G. CLARK Chief Building Official DGC/mh (PEI 6" Roof) UBC 17-5 ROOM FIRE TEST STANDARD FOR INTERIOR OF FOAM PLASTIC SYSTEMS Project No. 12480-93842 July 1, 1992 h Prepared for: Patio Enclosures, Inc. 720 East Highland Road Macedonia, Ohio 44056 Project No. 12480-93842 Patio Enclosures Inc. ABSTRACT July 1, 1992 Page n of iii This report describes the results obtained when 6" Insul-Roof insulated panels were tested in accordance with UBC 17-5 Room Fire Test Standard For Interior of Foam Plastic Systems. The test material was mounted on the ceiling of the test room. Flaming on the surface of the insulated panels did not extend to the outer extremities of the test area within a 15 -minute period and smoke levels generated during the test period were not excessive. The details, procedures and observations reported herein are correct and true within the limits of sound engineering practice. This report describes the analy- sis of a distinct assembly and includes descriptions of the test procedure followed, the assembly tested, and all results obtained. All test data are on file and remain available for review by authorized persons. The undersigned project manager was• responsible for the supervision of the construction of the test assembly and performance of the fire test. Signed: Reviewed an proved: erbert W. Stansberry I ilham . Fitch, P.E. No.55296 Project Manager Executive Vice President July 1.1992 July 1,199 Date Date �*SA !0. - O FRI, �eORATO'o Project No. 12480-93842 July 1, 1992 Patio Enclosures Inc. Page iii of iii TABLE OF CONTENTS Y= INTRODUCTION PAGE 1 PROCEDURE 1 TEST SPECIMEN 2 TEST RESULTS 3 CONCLUSIONS 5 APPENDICES Appendix A: CONSTRUCTION DRAWINGS 6 Appendix B: GRAPHICAL THERMOCOUPLE DATA 14 Appendix C: TABULAR THERMOCOUPLE DATA ~ ° ~ _ "' : ' 17 Appendix D: DETAILS OF DAMAGE :_ ;-.:.:. 20 - Appendix E: Appendix PHOTOGRAPHS 23 Last Page of Document 25_ SpA A r � ' Im Project No. 12480-93842 July 3, 1992 Patio Enclosures Inc. Page 1 DnRODUCTION This report presents the results of an investigation of a room corner fire test con- ducted according to UBC 17-5 "Room Fire Test Standard for Interior of Foam Plastic Systems". This document contains a description of the material evalu- ated, procedures used, and the results. Note that the results listed apply only to the specimens tested, in the manner tested, and not to the entire production of this or similar materials, nor to the performance of this material when used in com- bination with other materials. This procedure is technically equivalent to Underwriters Laboratories "Classification of Interior Finish Materials Using a Room Fire Test" (UL 1715), and PICC 401/March 1980, An Enclosed Room Fire Test," The Society of the Plastics Industry, Inc. PROCEDURE The standard test facility consists of an enclosed 8' wide, 12' long and 8' high room with walls and ceiling and a doorway 2-1/2' wide and 7' high centered in one of the 8' walls. When ceilings are included in the evaluation, an 8' square ceiling must have two edges resting on or adjoining the intersecting wall sections (see Appendix A, Fig. 1). All vertical or horizontal joint details must be representative of those intended for use in field conditions. The remainder of the interior of the room is constructed of gypsum wallboard screwed to 2" x 4" metal studs. The test structure is located inside a building which is free of excessive drafts. The fuel source is a wood crib constructed of 1.5" x 1.5" sticks of white fir cut into 15" lengths. The crib must have a dry wood weight of 30 lbs. and be 15" square in plan. One 8-d nail is driven at each intersection of two sticks. The , crib is assembled in tiers of five sticks each with each tier oriented 90 degrees to. the sticks in the adjacent tiers. Prior to placement in the test room, the crib is conditioned until the moisture content is 8 percent or less. The crib is placed on four brick pieces, one under each corner of the crib, to provide not less than a 3" space between the floor and the lower surface of the crib. Project No. 12480-93842 July 1, 1992 Patio Enclosures Inc. Page 2 Ignition of the crib is accomplished by evenly distributing 1 lb. of shredded and rfluffed wood excelsior beneath the crib over a 21" x 21" area and soaking with 4 oz. of ethyl alcohol. A minimum of four 24 ga. Type K, Chromel-Alumel thermocouples are utilized for temperature measurement in the test room. The placement of these thermocouples is shown in Figure 2 in Appendix A. Documentation of the test consists of 35mm color prints, color video tape and thermocouple data. Temperature readings on all thermocouples are taken prior to the start of the test and continued at 15 second intervals to the completion of the fire exposure. A wall or ceiling material is judged as having met the requirements of the test standard if it meets the following criteria: 1. Charring of the foam plastic shall not extend to the outer extremities of the test area within a 15 -minute period after ignition of the excelsior. Discoloration extending not more than 114"' into the foam plastic shall not be considered as charring. 2. Smoke levels generated during the test period shall not be excessive. S. Structural panels shall sustain the applied load during the test period. TEST SPECDMq The panels used to construct the room ceiling panel were identified as 6" Insul- Roof insulating panels. The foam cores used were nominal 1.5 PCF expanded poly -styrene foam and the sheet metal skins were .024" nominal thickness aluminum. The adhesive used to attached the skins to the cores was a one -part, moisture -cured urethane. The I -beams that formed the panel -to -panel joints consisted of two extruded aluminum T -beams joined together with an extruded plastic spline (Fig. 5, Appendix A). A tab/hanger bracket was mounted on the right side of the assembly to facilitate mounting to the side wall of the room (Fig. 4, Appendix A). Extruded aluminum fascia were used to cap the panels on the remaining three sides (Fig. 6, Appendix A). The overall size of the ceiling assembly was 9' square. The ceiling assembly covered a 8' square section of the r y Project No. 12480-93842 July 1, 1992 Patio Enclosures Inc. Page 3 q room with the remaining length overhanging the back: and lett side walls. A view of the completed ceiling assembly may be found in Appendix A (Fig. 3). Installation procedures followed are described in Appendix A (Construction Sequence). The remaining wall and ceiling sections were constructed of 5/8" type X gypsum wallboard screwed on 12" centers to standard 2" x 4" metal studs placed every 24". The interior dimensions of the room were 8'x 8'x 12' as specified in the standard. TEsrxESUnas The test was begun at 10:00 am, June 19, 1992, with Mr. Joseph Hetzel, of Patio Enclosures, Inc., in attendance. The ambient temperature was 84°F with a relative humidity of 70%. The thermocouples were positioned in accordance with the standard and their outputs verified after connection to the data acquisition system. The wood crib used in this test had the following properties: ( Wood Species: White fir Wood Grade: Construction Grade or better Avg. Moisture Content: 6.75% Crib Weight: 30.0 pounds TIlV1E (mi= _ 0B5'VATION . 0.00 Ignition of excelsior. 0:05 Ignition of the crib. 0:12 Flames reached 3' level. 0:23 Light smoke from excelsior, at 5' level. 0:47 Flames reached 4' level. �I 1:04 Flames reached 5' level 1:38 Flames reached 7' level 1:50 Room smoke dissipating. ' 2:05 Flames reached the ceiling. 2:05 Warpage of the panel skin on the panel in the corner. 222 Warpage of the panel skin on the second panel from the corner. �. 1W O��GO► po'y Project No. 12480-93842 Patio Enclosures Inc. July 1, 1992 Page 4 2:25 Warpage of the panel skin on the third panel from the corner. 2:47 Smoke leakage from the outside corner of the ceiling assembly. 3:10 Coating darkening on the panel over the crib. 3:57 Skin peeling from second panel along edge of I -Beam. 5:09 Coating darkening on the second panel. 6.52 Coating peeling directly over the crib. 9:28 Flames bleaching of the panel skin over the crib. 12:27 Flames receding; no longer touching the ceiling. 12:44 Flames at the 7' level. 14:07 Flames at the 6' level. 15:00 Crib extinguished; test terminated. Additional Observations Insulated panels on the ceiling had no after -flame. The paint on the ceiling was blackened in an area extending roughly 4' from the corner along each wall. The paint was consumed in a small area (roughly 1' square) directly above the crib. The metal skin of the panels was warped in an triangular area extending to the extremities of both the back and side walls and approximately 2' along their adjoining walls. A diagram of these damaged areas may be found in Appendix D (Fig. 7). After removing the sheet metal skins from the panels, the damage to the foam cores could be observed. The EPS was completely consumed and the underside of the upper metal skin was discolored in an area roughly 2' square directly over the crib. The EPS foam was still intact and slightly melted along the two overhanging sides of the ceiling assembly. About 1/4" of EPS was left; in an area extending, from 4" beyond the corner, 3-1/2 to 4' along both corner walls. Approximately 1- 1/2" of EPS remained in the area from the aforementioned section roughly 6-1/2' along both walls. The remaining area was left with a thickness of about 3 to 5" of EPS. Several small patches of completely undamaged EPS foam existed along the right side wall and the front of the ceiling assembly. A diagram of these damaged area may be found in Appendix D (Fig. 8). A P0 ino, oliAvoo Project No. 12480-93842 July 1, 1992 Patio Enclosures Inc. Page 8 J ' t i At no time during the test did liquified EPS enter the testing chamber. No drips, flaming or otherwise, were noted inside the room. No burnthrough was present on the sample and the outside surface of the corner remained cool throughout the duration of the test. CONCLUSIONS The test was completed with the entire ceiling visible at all times after the first minute. Smoke generation during the first minute was due to the excelsior material and the wood crib. Minimal damages as described above occurred. The smoke level was low. b1► -Jb' INS e0�ATO�,Q► CORIRIERCIIIL TEST1118, COMPRff 3 Standard Test Method for : SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS ASTM E 84-89a Material Tested: Aluminum over EPS Report Number 78757-R Test Number 2268-8426 May 21, 1991 Prepared for: Patio Enclosures, Inc. Macedonia, Ohio COMMERCIAL TESTING COMPANY Jonathan Jackson Executive Vice President I TESTINO . RESEARCH • ENOINEERINO INTRODUCTION: I This report represents test results on a material submitted for testing by Patio Enclosures, Inc., of Macedonia, Ohio. The test was conducted in accordance with the American Society for Testing and Materials Standard Test Method for "Surface Burning Characteristics of Building Materials," E 84-90, also known as the Steiner Tunnel Test. This method is similar to ANSI 2.5, NFPA No. 255, UBC No. 42-1, and UL No. 723. This method has been approved for use by agencies of the Department of Defense and for listing in the DoD Index of Specifications and Standards. The E 84 standard should be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions. It should not be used for the appraisal, description, or regulation of the fire hazard or fire risk of the materials. No consideration is made for results that may be obtained if the material being evaluated were tested in combination with other materials. In the light of present knowledge, fire performance of any material cannot be evaluated on the basis of one test. However, results of this test may be used as one element of a fire risk assessment that takes into account all of. the factors which are pertinent to an assessment of the fire hazard of a particular end use. These test results represent only the sample tested and are not necessarily indicative of apparent identical or similar materials. .All test data are on _ file and available for review by authorized persons. PURPOSE: The purpose of this test method is to determine the relative burning behavior of a material by observing the flame spread along the surface of the specimen. It is intended to provide comparative measurements of surface flame spread and smoke development of materials with that of select grade red oak and inorganic fiber .reinforced cement board under specific fire exposure conditions. The test exposes a nominal 24 -feet long by 21 -inches wide specimen to a controlled air flow and flaming fire adjusted to spread the flame along the entire length of a red oak specimen in 5} minutes during a 10 -minute test duration while flamespread over its surface and density of the resulting smoke are measured and recorded. Test results are calculated relative to the red oak specimen, which has an arbitrary rating of 100, and the cement board, which has a rating of 0. The test results are expressed as Flamespread Index and Smoke Density. However, there is not necessarily a relationship between these two measurements. TEST PROCEDURE: The test specimens, selected and identified by the Client, were conditioned to equilibrium in an atmosphere with the temperature maintained between 69°F and 73°F, and the relative humidity between 47 and 53 percent. The zero �iiiiill� ..j reference and other parameters critical to furnace operation were verified on 4^ the day of the test by conducting a 10 -minute burn using J -inch cement board. Periodic tests using NOFMA certified select grade red oak flooring provided data for the 100 reference. The material were then tested in accordance with test method procedures. TEST SPECIMENS: Identification: Aluminum over EPS Composition: Aluminum covered EPS panels consisting of Falcon Manufacturing 1.5 lbs/ft9 density EPS covered on both sides with Nichols Homeshield 0.024 -inch aluminum 3105-H174. The aluminum is adhered to the EPS with Morton Thiokol Mor -AD Adhesive. Finished thickness of the panels is nominally 3 inches. Mounting: The panels as received were physically self-supporting and required no additional sample preparation. The panels were placed onto the ledges of the tunnel furnace and the test conducted as specified in the E 84 standard. TEST RESULTS: Test results, calculated on the basis of observed flame propagation and the integrated area under the recorded smoke density curve, are presented below. In recognition of possible variations due to limitations of the test method, the results are rounded to the nearest number divisible by five. Data for flame spread and smoke development are shown as solid lines on the computer generated graph at the end of the report. FLAMESPREAD SMOKE Test Specimen INDEX DENSITY GRC Board 0 0 Red Oak 100 100 Aluminum over EPS 15 80 OBSERVATIONS: Specimen ignition was recorded at 0.74 minutes with a maximum flame spread distance of 4.2 feet at 4.74 minutes. The maximum temperature recorded during the test was 629°F. The aluminum covering the EPS stayed in place and prevented the molten foam plastic from entering the test chamber during the 10 -minute test duration. There was no afterflame after extinguishment of the tunnel furnace burner. E 84 TUNNEL TEST DATA SHEET CLIENT: PATIO ENCLOSURES INC. TEST NUMBER: 2268-8426 MATERIAL IDENTIFICATION: ALUMINUM OVER EPS DATE: MAY 21s 1991 TEST RESULTS: TIME TO IGNITION = 8.74 MINUTES DISTANCE MAXIMUM SPREAD s 4.2 FEET TIME TO MAXIMUM SPREAD = 4.74 MINUTES FLAME SPREAD INDEX = 15 ' FUEL CONTRIBUTED a 18 SMOKE DEVELOPED INDEX = Be 28 F L A M E18 P R A D8 8 dotted line a Med oak 8 28 x T- 48 M 68 K 88 E ' 1885 1 2 3 4 5 6 7 8 9 18 TIME (MINUTES) 1 676 -' SUBJECT City of Fridley 2 215 AT THE TOP OF THE TWINS BUILDING PERMIT i COMMUNITY DEVELOPMENT DIV. �° _ ►; PROTECTIVE INSPECTION SEC. r e NUMBER REV DATE PAGE OF APPROVED By i A '►',`; CITY HALL FRIDLEY 55432 .►►► Z Jae 612-571-3450 1 910-F15 9/30/93 JOB ADDRESS 5627 West Bavarian Pass NE 1 LEGAL LOT NC BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 1 18 Innsbruck Villages SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Lyle/Jan Christie/Hoffman 5727 West Bavarian Pass NE 571--4234 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Patio Enclosures. Inc 5120 Cedar Lake Rd, St Louis Park 55416 525-1494 1676 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 6 USE OF BUILDING Residential 7 CLASS OF WORK ❑ NEW ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 8 DESCRIBE WORK Construct a 10t x 121 Three Season Porch_ Addition 9 CHANGE OF USE FROM TO STIPULATIONS See notations on plan. WARNING Before digging call for all utility locations 454.0002 REQUIRED BY LAW TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. ZONING SQ. FT. CU. FT. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT NO. DWLG. UNITS OFFSTREET PARKING ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION I STALLS GARAGES VALUATION SURTAX AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $10,400 $5.20 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT PERMIT FEE SAC CHARGE DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE P OVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- $12.6.00 Fire SC $10.40 S CTION OR THE PERFORMANCE OF CONSTRUCTION. PLAN CHECK FEE TOTALFEE License SC $5,0 $146.60 SIGNATURE OF CONTRACT R OR AUTHORIZED AGENT IDATEI WHE P ALIDATED THIS IS YOUR PERMIT BLDdr INSP DATE SIGNATURE OF OWNER 0F OWNER BUILDERI IDATEI F NEW [ ] ADDN ALTER [ ] Effectiv 3/ 11�12 CITY OF FRIDLEY SINGLE FAMILY AND DUPLEXES R-1 AND R-2 Building Permit Application Construction Address: IT7 W, & /1 PASS Legal Description: Owner Name & Address: Ali If ehr'04 BL d AAD Hog � � Tel. # 5"7/- YZ3Y Contractor: �,4 ��� �A/� 1�r�� ,Zjt��, MN LICENSE # 1b %� Address: 6/20 C, -64W 1-41fe AM 5.5'5116 Tel. # .'o?5'- / V9 V _ Attach to this application, a Certificate of Survey of the �t¢X 5-2,5— If -q7 lot, with the proposed construction drawn on it to scale. J;,,", U} ; Jje e DESCRIPTION OF IMPROVEMENT LIVING AREA: Length Width Height Sq. Ft. GARAGE AREA: Length Width Height Sq. Ft. DECK AREA: Length Width HgYGround 5" Sq. Ft. OTHER: ®® A e H / 10 12- .fi`''®/re eFeP.5,0,✓ .4hocevi Saeveq /4No ,she s vio 14Aa vA 4✓e 6a Corner Lot j ] Inside Lot ' Ft. Yd Setback lige Yard Sacks Type of Construction: 95 a de/)i&,1- Estimated Cost: $ /0.41 l&4 Approx. Completion Date: 943019.3 (Cost on Back) Driveway Curb Cut Width Needed: Ft. + b Ft = Ft x $ = $ DATE: % % r�...3 APPLICANT: ` _.te2 Tel. 00 Permit Fee $ %' ee" On Fire Surcharge $ / 0 , V o State Surcharge $ 57. �2 C' SAC Charge $ License Surcharge $ 'S ' D o Driveway Escrow $ Park Fee $ Sewer Main Charge $ TOTAL STIPULATIONS: $ I y tc, &0 CITY USE ONLY Fee Schedule on Reverse Side .001 of Permit Valuation (1/10th%) $.501$1,000 Valuation $700 per SAC Unit $5.00 (State Licensed Residential Contractors) Alt. "A" or Alt. "B" Above Fee Determined by Engineering Agreement Necessary j ] Not Necessary [ IA(jAIS1PRUCK " Maims n�tenatce�itt July 1,J, 1993 VILLAGES I Association Jan 1=1865man j Kyle Christie 5627 W. Bavarian Pass Fridle,,:, Mn 55432 Per your request, this is notific:1, n that your motion for the addition of a three season porch to your -.own home, presented at June 1993 Homeowners Meeting was passed. The riotion was presented with t ,- assurance that the porch would conform to the current buildi.Ag standards as regards col)r, siding and roofing appearance and general blending with the current buildings appearance as you describe at the meeting. Since: the additions made to build ngs in the association are not covered by the normal mainu nance, I would suggest that you would "add" the porch to future scheduled work which is plann:d by the association such ads painting and normal maintenance, This may be done by costa: ting the maintenance chairtlerson (me for now) when association work is scheduled, get the n erne of the contractor doing the work for the association, and arranging to have your work done it the same time, at your exicnse. This is usually more cost effective for you. Enjo). your new porch. Sinc§:Tcly, • r� `J1 C. Thomas Eldredge Chair-- - Maintenance Committee Inns'�� •-uk Villages Association Board of Directors. R s Innsbruck Villages Associatiory Maintenance Committee , 5624 W. Bavarian Pass, Fridley, MN 55432 i Office: 635-4470 Home. 571-ss83 City of Fridley SUBJECT 4t#M IT NO. 2.979 AT THE TOP OF THE TWINS r BUILDING PERMIT( EIPT NO. E � • COMMUNITY DEVELOPMENT DIV. r E PROTECTIVE INSPECTION SEC. 1 i CITY HALL FRIDLEY 55432 NUMBERREV ATE PAGE OF APPROVED BY 612-571-3450 910 F15 3/28/97 ID JOB ADDRESS See Below - Multiple Buildings 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO Columbus Exteriors Inc 2131 111 In, Coon Rapids MN 55433 868-9195 3509 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO 6 USE OF BUILDING Townhouse Buildings 7 CLASS OF WORK O NEW O ADDITION 0 ALTERATION REPAIR G MOVE O REMOVE 8 DESCRIBE WORK Reside 11 Buildings 9 CHANGEOFUSEFROM TO STIPULATIONS Install building wrap and have inspection of same unless manufacturer" - specifications state it is not required. 5600,5602,5604,5606 North Innsbruck Ct; 1511,1513,1515,1517 North Innsbruck Dr; 1510,1512,1514,1516 Trapp Ct; 1531,1533,1535,1537 Trapp Ct; 1511,1513,1515,1517 Trapp Ct; 5610,5612,5614,5616 W Bavarian Pass; 5621,5623,5625 5627 Bavarian Pass; 5631,5633,5635,5637 W Bavarian Pass; 5651,5653,5655,5657 W Bavarian Pass; 5680, 5682,5684,5686 West Bavarian Pass; 5691,5693,5695,5697 West Bavarian Pass SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL. PLUMBING, HEATING, TYPE OF CONST OCCUPANCYGROUP OCCUPANCYLOAD VENTILATING OR AIR CONDITIONING THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT THE GRANTING OF A PERMIT $232,000 $116.00 DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- STRUCTION OR THE PERFORMANCE OF CONSTRUCTION $.,547.25 Fire SC $232.00 7 PLAN CHECK FEE TOTAL FEE LieSC 5.00 $1,900.25 SIGNA EOFCOWPACTORORAUT.IORIZEDAGENT (DATE, H NP ERLY V IDATED THIS IS YOUR PERMIT 0/0' SGNA^.IRE Oc (VNEP-I' O�%NER Buwt DER, IDATE, i^(, I 5P nAT{ SUBJECT �I City of Fridley �05'7 AT THE TOP OF THE TWINS BUILDING PERMIT f NO. • _____ COMMUNITY DEVELOPMENT DIV. `L - r 1 � PROTECTIVE INSPECTION SEC. �q i A "" ;� CITY HALL FRIDLEY 55432 NUMBER REV GATE PAGE OF APPROVED By ---- . L J� 612-571-3450 910-F15 5/13/97 JOB ADDRESS 5627 West Bavarian Pass NE 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 1 I 18 Innsbruck Villages SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Lyle Christie 5627 West Bavarian Pass NE 571-4234 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO Justus Lumber 330 11 Ave S, Hopkins HN 55343 938-2741 2780 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO 6 USE OF BUILDING Residential 7 CLASS OF WORK O NEW ❑ ADDITION J] ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 8 DESCRIBE WORK Replace two windows 9 CHANGE OF USE FROM TO STIPULATIONS Replacement bedroom windows must meet the State Egress Code. Install smoke detectors to meet the State Building Code.. TYPE OF CONST. OCCUPANCY GROUP OCCUPANCYLOAD SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SQ. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING 1 I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $2,550 $1.27 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SACCHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- $74.75 Fire SC $2.55 STRUCTION R THE PER€ORMANCE OF CONSTRUCTION r PLAN CHECK FEE TO L FEE X� /3 Lic e $5. $83.57 SIGNATURE 5F CONTRACTOR ORAUTHORIZED AGENT ID TEI ENAOP VALID D THIS IS YOUR PERMIT `=13 r SIGNATURE OF OWNER OF OWNER BUILDERI IDATEI - BLD INSP TE NEW ( ] Effective 1/1/97 ADDN [ ] CITY OF FRIDLEY ALTER [ ] SINGLE FAMILY AND DUPLEXES R-1 AND R-2 BUILDING PERMIT APPLICATION ConstructionAddress: �-G A% W. 136092SAN C S. Legal Description: Owner Name & Address: O L 6- C H 2► S :1 r Tel. # S 71- y 2 3 y Contractor: 'SV s-ry s LuM 0 6P— MN LICENSE # A7 F o Address: 330 111-1' 6Vt S /- -5Y3g3 Tel. # g3F-A-741 Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF H"ROVEIIENT LIVING AREA: Length Width Height Sq. Ft. GARAGE AREA: Length Width Height Sq. Ft. DECK AREA: Length Width Hgt/Ground Sq. Ft. OTHER: kEeL ICr TWO w"/1200J c MANE sjzC f-1 S License Surcharge Construction Type: Driveway Curb Cut Width Needed: Ft. + 6 Ft = Estimated Cost: $ (Fee Schedule on Back) Ft x $ _ $ DATE: S113APPLICANT: Tel. # 7`j1 STIPULATIONS: CITY USE ONLY Permit Fee $ % Fee Schedule on Reverse Side Fire Surcharge $ . �^ .001 of Permit Valuation (1/10th%) State Surcharge $ /- $.50/$1,000 Valuation SAC Charge $ $950 per SAC Unit License Surcharge $ S-,610 $5.00 (State Licensed Residential Contractors) Driveway Escrow $ Alt. "A" or Alt. "B" Above Erosion Control $ -$450.00 Conservation Plan Review Park Fee $ Fee Determined by Engineering Sewer Main Charge $ Agreement Necessary [ ] Not Necessary [ ] TOTAL $ (�13 . S �7 STIPULATIONS: CITY OF FRIDLEY PERMIT NO.: 2004-01787 6431 UNIVERSITY AVENUE NE FRIDLEY, MN 55432 DATE ISSUED: 10/05/2004 572-36U4 YAX: (763) 571-1287 ADDRESS : 5627 W BAVARIAN PASS NE PIN : 243024410218 LEGAL DESC : INNSBRUCK VILLAGES : LOT 1 BLOCK 18 PERMIT TYPE : ELECTRICAL PROPERTY TYPE : TOWNHOUSES CONSTRUCTION TYPE : ADDITION/ALTERATION VALUATION NOTE: ELECTRICAL PERMIT BECOMES VOID 12 MONTHS AFTER PERMIT ISSUE DATE. INSTALL A SAVERS SWITCH. # INSPECTIONS 1 APPLICANT HUNT ELECTRIC CORPORATION 2300 TERRITORIAL RD ST PAUL, MN 55114- n 1AFRO W_ JANACE MOSS 5627 W BAVARIAN PASS NE FRIDLEY, MN 55432 AGREEMENT AND SWORN STATEMENT This permit becomes null and void if work or construction authorized is not commenced witin 60 days or if construction or work is suspended or abandoned for a period of 120 days at any time after work is commenced. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of wort will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. Applicant Date Bldg Insp Date ELEC PERMIT FEE - MIN (RESI) 20.00 STATE SURCHARGE, ELEC FLAT 0.50 TOTAL 20.50 PAID WITH CHECK # 118132 SEFAKATE FERWI'S REQUIRED FOR WORK OTHER THAN DESCRIBED ABOVE.