L J \ 612-560-3450
910-F15
12/30/77
L
JOB ADDRESS 5656 West Bavarian Pass N.E.
1 LEGAL
LOT NO.
BLOCK
TRACT OR ADDITION SEE ATTACHED
DESCR.
2
3
Innsbruck villages SHEET
2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE
Darrel A. Farr Development Corp. 7286 - 72nd Lane No. 560-8110
3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO.
Same
4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO.
5 ENGINEER MAILADDRESS ZIP PHONE LICENSE NO.
6 USE OF BUILDING
Residential
7 CLASS OF WORK
❑ NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE
x
8 DESCRIBE WORK
Construct a 24' x 35.5' Townhouse and a 20' x 23' Garage (Sunnenheim)
9 CHANGE OF USE FROM TO
STIPULATIONS Provide combustion air to furnace area.
TYPE OF CONST.
OCCUPANCY GROUP
OCCUPANCY LOAD
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
VENTILATING OR AIR CONDITIONING.
Wood Frame
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
ZONING
SQ. FT.
CU. FT.
AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION
984+460
Total
OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT
R-1
.22,936.
ANY TIME AFTER WORK IS COMMENCED.
NO. OWLG. UNITS
OFFSTREET PARKING
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
1
STALLS GARAGES
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
VALUATION
SURTAX
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED.
$15.19
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT
$30,375
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PERMIT FEE
SACCHARGE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON-
$375.00
STRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
$91.74
PLAN CHECK FEE
TOTAL FEE
$22.94
$504.87
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT (DATE)
q ' W EN PR ER LI TED HIS IS YOUR P� SIT
f
BLDG. )NSP DAT
SIGNATURE OF OWNER IIF OWNER BUILDER) (DATE)
A111'L1(;'TION 1:011%
OR ADDITION 131UII,I)ING 1'J:Iti•I11'
CITY Ul ] I:Ill1J;1', •tTi\,�t:S�?'I'��
0. -IN IIS NAME:�A J, De - . &,,q,utrILDF:R: 13,2;9% PC
ADDRESS :7j et. � Lake. Aloy$4 ADDRESS : � ►. SSS- 8
s
LOT: BLOC:: ADDITION: .��!�1X AVeftl
CORNER LOT: INSIDE LOT: SETBACK: ; * SIDE -YARD:
Applicant attach to this form Tc -7o Certificates of Survey of Lot and proposed
building location drawn on these Certificates.
DESCRIPTION OF BUILDING
Scto-r.-P elop 04
To .Be Used As:
�r� �►�s�
Front: a4- Depth : .3 Height: 2 O
Square Feet:-46ih9Z Cubic Feet: ��Z0 0
-23 -2-: , 9J4 \
Q§- Front:2,0 Depth : Height: / O �� �� , t
—<6® �1
Square Feet; ''IaO Cubic Feet: x``900
Type of Construction: Woo4 Ft -a e, Estimated Cost: $
To Be Completed:—
The_
The undersigned hereby makes application for a permit for the work herein
specified, agreeing to do all work in strict accordance with the City of
Fridley Ordinances and rulings of the Department of Buildings, and hereby
declares that all the facts and representations stated in this application
are true and correct.
DATE: % sirNATUP.E : 0 /�
(See Reverse Side For Additional information.)
SAC'
?1eW I D� Nm8us n �3 /4, e- To
FurA), Aebq'
MECHANICAL WARM AIR:
Signed By
Furnace Shell & Duct Work to 100,000 BTU
APPLICATION FOR
POWER PLANTS AND HEATING,
COOLING, VENTILATION, REFRIGERATION AND
4.00
.AIR
CONDITIONING SYSTEMS AND DEVICES
PARTIAL RATE SCHEDULE
$
Repairs & Alterations -up to $500.00
.
GRAVITY WARM AIR:
RATE
TOTAL
,�+
,lob Address e5 lPS 0
Furnace Shell & Duct Work
$12.00
$
Boiler & Lines up to 100,000 BTU
Replacement of Furnace
7.00
$
4.00
Repairs & Alterations -up to $500.00
7.00
$
Department of Buildings
Repairs & Alterations each add. $500.00
4.00
$�
City of Fridley
$10.00
$
each add. 3 gal. per hour
Tel. #571-3450
MECHANICAL WARM AIR:
Signed By
Furnace Shell & Duct Work to 100,000 BTU
$12.00
$ o0 0
each add. 50,000 BTU
4.00
S
Replacement of Furnace
7.00
$
Repairs & Alterations -up to $500.00
7.00
$
Repairs & Alterations each add. $500.00
4.00
$
STEAM OR HOT WATER SYSTEM:
Boiler & Lines up to 100,000 BTU
$12.00
$
e4ch addn. 50,000 BTU
4.00
$
Boiler only up to 100,000 BTU
7.00
$
each addn. 50,000 BTU
6.00
$
OIL BURNER- to 3 gal. per hour
$10.00
$
each add. 3 gal. per hour
10.00
$
GAS BURNER- from 100,000 BTU to 199,999 BTU
$10.00
$ 1,0,e
(over 199,999 BTU see Fee Schedule)
$
GAS FITTING FEES:
1st 3 Fixtures x
$ 3.00
$
Additional Fixtures x
$ 1.00
$
Gas Range to 199,000 BTU x
$10.00
$
AIR CONDITIONING 9M'4//'9 L��-/
$
FAN HEATING SYSTEMS See Fee Schedule
$
VENTILATING SYSTEMS
$
ALTERATIONS & REPAIRS
$
State Surcharge
$ .50
TOTAL FEE
$ � S®
ROUGH INSP. REINSPECTION FEE
Date s� ($10.00)
FINAL INSP. I `
Date
APPROVAL FOR PERMIT
MINIMUM FEE FOR ANY HEATING PERMIT 13 $7.50 PLUS $.50 STATE SURCHARGE
The undersigned hereby makes application for a permit for the work herein
specified agreeing to do all work in strict accordance with the City Codes
and rulings of the Department of Buildings, and hereby declares that all the
facts and representations stated in this application are true and correct.
,F�r'idley, Minn. 9-31 , 1929
OWNER ,~eZ / ✓�IZ&
KIND OF BUILDING
USED AS
TO BE COMPLETED ABOUT 20
ESTIMATED COST CRC? &®
OLD - NEW BUILDING PERMIT NO. PERMIT NO.
DESCRIPTION OF FURNACE/BURNER
HEATING or POWER PLANTS, Steam, Hot Water,(Warm Air- No.
Trade Name M4,074- Size No. ffJT�e4z=_ e
Capacity Sq. Ft. EDR BTU HP
Total Connected Load a -9 -7-79 Kind of Fuel Com$
BURNER - Trade Name Size No.
Capacity Sq. Ft. EDR BTU HP
L"Ju. v
Company
Signed By
Tel. No.
,r
e,.HEAT LOSS CALCULATIONS 4
q -7 ++
f
MINNEAPOLIS MINN
Weatherstrips A.S. H. V. E, Construction No. r .
Insulation
Windows Doors Guide Out. Mall Int. Wall Ceiling Roof Floor Kind
Reference How Applied
Yes --No Yes—No 18
FI. Room Length Width ®
Windows and Doors—Crackage and Area
Nb. Width Height No. of Lineal ft. Area
of pane of pane lights of crack sq. ft.
HeightQ
9
FI Room Length® Width ® Height
Windows and Doors—Crackage and Area
No. Width Height No. of Lineal ft. Area
of pane of pane lights of crack sq. ft.
� ,
Coef Btu
Infiltration 7
Glass
Exp, we I I
Net exp, wall
Int. wall
Coef Btu
Infiltration �
Glass
Exp. wa I I E
Net exp. wall 9
d
Ceiling
Floor ®
Total Btu.
Int. wall
Ceiling ,� `®� 2
Floor
�
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
Width Height
Windows and Doors—Crackage and Area
No. Width Height No. of Lineal ft. Area
of pane of pane lights of crack sq. ft.
Total Btu.
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
FI Room I Length/Width /0 Height
Windows and Doors—Crackage and Area
of pane of pane lights of crac�3
No, Widrh Height No. of Lineal ?_Lf
Goef
Btu
F�4 -
Btu
Infiltration
Glass
Exp. wall
Infiltration
Glass
Exp. wall
wall
Net exp, we l
Int. wall
Int. wap.
Ceiling
Ceiling
Floor
Floor
Total Btu.
Total Btu.
Required sq. ft. E.D.R. or sq. ins. W.A. Leader. area
FL t Room Length l Width
Windows and Doors—Cracka e and Area
g
No, Widrh Height No. of Lineal ft. Area
of ne of pa a lights of crack sq. ft,
HeightFI.
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
B & om Length Width
Windows and Doors—Crackage and Area
No. Width Hi:,ght No. of Lineal ft. Area
of pane of pane it is of crack sq. ft,
Height
Coef
Btu
--------------
Infiltration
Glass
Coe
Btu
Infiltration
Glass+
Exp. wall
Exp, wall
:I'I
Net exp. wall
_
Net exp, wall
r
Int. wall
Int. wall
Ceiling ®�
Floor
Ceiling
Floor
Total Stu.
------------------
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
Total Btu.
Required sq. ft. E•DF,. or sq. ins. W.A. Leader area
I
flAII�INF�Pr11 IC AAlnln!
Weatherstrips A. S. H. V. E. Construction No u�.�v �• Insulation
Windows Doors Guide Out. Wall Int. Wall Ceiling Roof Floor Kind How Applied
Reference
Yes -No Yes -No 19 -
Fl �!' Room Length Width ®Q Height F1.4l, Room Length Width ® Height
Windows and 150 rs—Cracka
7
HEAT LOSS CALCULATIONS
TO
ARM
9%-nPunn7tlnann men— o -n
flAII�INF�Pr11 IC AAlnln!
Weatherstrips A. S. H. V. E. Construction No u�.�v �• Insulation
Windows Doors Guide Out. Wall Int. Wall Ceiling Roof Floor Kind How Applied
Reference
Yes -No Yes -No 19 -
Fl �!' Room Length Width ®Q Height F1.4l, Room Length Width ® Height
Windows and 150 rs—Cracka
Windo s and Doors—Crackage and Area
No. Width Height
of ane of pane
light
No. o14W
No.
No. of Lineal ft. Area
lights of crack sq. ft.
S[2�
Coefi
Btu
Coef Btu
Infiltration
Glass
rg
®S(j
Infiltration
Glass
1
Exp, wall ®
Exp. wall"
Net expwal I
•Int. walll
°c
Net exp. wal I
Int. wall
®®
Ceiling°
Floor
�
Ceiling
Floor
Total Btu.
Total Btu.
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
FI. Room Length Width
Height
FI. Room Length Width Height
WindAs and Doors—Crackage and Area
Windows and Doors—Crackage and Area
Width Hei ht
No. a No. of Lineal k Area
of pane of pane lights of crack sq. ft.
No. Width Height No. of Lineal ft. Area
of pane of pane lights of crack sq. ft.
® ®
Coef Btu
Coef
Btu -"
Infiltration
Infiltration
Glass
Q
Glass
-
Exp. wall ®�
Exp. wall
Net exp. wall
Net exp. wall
Int. wall
Int, wall
�a
Ceiling y
Ceiling
Floor
Floor
Total Btu. Z-
-
Total Btu.
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
Required sq. ft. E.D.R. or sq. ins. W.A. Leader area
Fl. Room Length Width Height
Fl. Room
Length Width Height
Windows and Doors-Crackage and Area
Windows and Doors-Crackage and Area
No. Width Height No. of Lineal ft.
of ane of ane lights of crack
A•ea
sq. ft.
No W,nin Height No. of Lineal ft. Area
of pane of pane lights of crack sq, ft.
Coef Btu
Coef Btu
Infiltration
Infiltration
Glass
—[a s—s
Exp. wall
Exp. wall
j
!
Net exp. wall
Net exp. wall
Int. wall
Int. wall
Ceiling
Ceiling
Floor
Floor
+vaar ow• - - - Total Btu.
Required"sq. ft. E.D.R. or sq. ins. W.A. Leader area Required sq. ft. E.D.R, or sq. ins. W.A. Leader area
CITY OF FRIDLEY
APPLICATION FOR PWMBING AND GAS FITTING PERMIT
Job Address �6 BCO
Department of Buildings
City of Fridley
Tel. #571-3450
The undersigned hereby makes application for a permit for the work herein
specified agreeing to do all work in strict accordance with the City Codes
and rulings of the Department of Buildings, and hereby declares that all
the facts and representations stated in this application are true and correct
{Fridley, Mn. ` , 19 JD
OWNER r'.
KIND OF BUILDING
USED AS
TO BE COMPLETED ABOUT
PARTIAL RATE SCHEDULE
�
Water
0
-01m
PLUMBING FIXTURE RATES:
NO.
RATE
E-1
to
ym�
�
e(d
u
a
w
Heater
—4
k m
to
$
C
m
ti.
43
N
M
.iC R
Fol
Catch Basin
x
$5.00
Signed BY
W
a
m
$
.��
i+ o
°a
g
ro m
ro
$
uCi
m
ag.04
var.
U
O
to
H
3
Caw
y
w
U w
.t 3
ROUGH INSP.
Electric Water Heater
O
as
lec
Date
GAS FITTING FEES:
•
FINAL INSP.
lst 3 fixtures
_x
"$3.00
$
3.0
' Date
Additional Fixtures
x
$1.00
$
Gas Range to 199,000 BTU
x
$10.00
$
APPROVAL FOR PERMIT
REPAIRS & ALTERATIONS
1st
First $100.00
$5.00
$
each add. $100.00 or fraction
$2.00
$
MINIMUM FEE FOR ANY PLUMBING PERMIT IS $7.50 pLUS $.50 STATE SOLE
State Surcharge
2nd
.50
TOTAL FEE
$
'Y
REINSPECTION FEE
3rd
4th
(R) = Future Connection Opening
Connected with Sewer
(*) = New Fixture, Old Opening
Water
Job Address �6 BCO
Department of Buildings
City of Fridley
Tel. #571-3450
The undersigned hereby makes application for a permit for the work herein
specified agreeing to do all work in strict accordance with the City Codes
and rulings of the Department of Buildings, and hereby declares that all
the facts and representations stated in this application are true and correct
{Fridley, Mn. ` , 19 JD
OWNER r'.
KIND OF BUILDING
USED AS
TO BE COMPLETED ABOUT
PARTIAL RATE SCHEDULE
ESTIMATED COST
PLUMBING FIXTURE RATES:
NO.
RATE
TOTAL
OLD - NEW BUILDING PERMIT NO.
PERMIT NO.
Number Fixtures
L x
$3.00
Future Fixture Opening
x
$2.00
$
011p1nyEa
ti.
New Fixture, Old Opening
x
$2.00
$
Catch Basin
x
$5.00
Signed BY
Water Heater - to 99,000 BTU
f'���"[FF���
T x
$5.00
$
.��
Tei. No.
�% - 4// 931
100,000 BTU to 199,000 BTU
x
$10.00
$
Water Softener
x
$7.00
$
New Ground Run Old Building
x
$5.OU
$
ROUGH INSP.
Electric Water Heater
x
$5.00
$
Date
GAS FITTING FEES:
•
FINAL INSP.
lst 3 fixtures
_x
"$3.00
$
3.0
' Date
Additional Fixtures
x
$1.00
$
Gas Range to 199,000 BTU
x
$10.00
$
APPROVAL FOR PERMIT
REPAIRS & ALTERATIONS
First $100.00
$5.00
$
each add. $100.00 or fraction
$2.00
$
MINIMUM FEE FOR ANY PLUMBING PERMIT IS $7.50 pLUS $.50 STATE SOLE
State Surcharge
$
.50
TOTAL FEE
$
'Y
REINSPECTION FEE
(S10.O�J)
97-84-416051
CITY OF FRIDLEY
• APPLICATION FOR PLUMBING AND GAS FITTING PERMIT
PARTIAL RATE SCHEDULE
PLUMBING FIXTURE RATES:
NO.
RATE
TOTAL
Number Fixtures
x
$3.00
m
Future Fixture Opening
x
$2.00
v
New Fixture, Old opening
x
br
$
Water
e
b
Catch Basin
°�Aj
$5.00
b
C
e
$5.00
m
+� s,
w
w
�
Water Softener
Heater
$7.00
_
$
New Ground Run old Building
x
$5.00
e
Electric Water Heater
�
$5.00
$
GAS FITTING FEES:
�
1st 3 fixtures
x
•$3.00
$
Additional Fixtures
$
' o
•�
ar�r��7
x
�
H
�
0
8
+� "v,
�
run
$
�J
M
V
5
00
ymy
W
to
3
O w°
vii
W
U 00
3
eayp
C9
�mE
t7
0
S
1@C
1st
n,
2nd
3rd
4 th
(R) - Future Connection Opening
Connected with Sewer
M s New Fixture, Old Opening
Water
PARTIAL RATE SCHEDULE
PLUMBING FIXTURE RATES:
NO.
RATE
TOTAL
Number Fixtures
x
$3.00
$
Future Fixture Opening
x
$2.00
$
New Fixture, Old opening
x
$2.00
$
Catch Basin
x
$5.00
$
Water Heater - to 99,000 BTU
x
$5.00
$
100,000 BTU to 199,000 BTT
x
$10.00
$
Water Softener
x
$7.00
_
$
New Ground Run old Building
x
$5.00
$
Electric Water Heater
x
$5.00
$
GAS FITTING FEES:
1st 3 fixtures
x
•$3.00
$
Additional Fixtures
x
$1.00
$
Gas Range to 199,000 BTU
x
$10.00
$
REPAIRS $ ALTERATIONS
First $100.00
$5.00
$
each add. $100.00 or fraction
$2.00
$
State surcharge
$ .50
TOTAL FES
$ 10.50
REINSPECTION FEE
(510.00)
Job Address 5656 West Bavarian Pass
Department of Buildings
City of Fridley
Tel. #571-3450
The undersigned hereby makes application for A permit for the work herein
specified agreeing to do all work in strict accordance with the City Codes
and rulings of the Department of Buildings, and hereby declares that all
the facts and representations stated in this application are true and correct
Fridley, Mn. 9-19-78 . 19
OWNER FARR DEV®
KIND OF BUILDING r 3'TIB
USED AS
TO BE COMPLETED ABOUT 9-26-78
ESTIMATED COST 20.00 n .
OLD - NEW BUILDING PERMIT NO. PERMIT NO. /
Company
MININEGASC .
Signed By
Tel. No.
ROUGH IN".
Date
FZrimINSP. 7,7
Date
APPROVAL FOR PERMIT
MINIMUM FEE FOR ANY PLUMBING PERMIT IS $7.50 PLUS $.SO STATE SMCMUM
SUBJECT
City of Fridley240
a9
AT THE TOP OF THE TWINS
BUILDING
PERMIT
r
RECEIPT NO.
t • COMMUNITY DEVELOPMENT DIV
r � � PROTECTIVE INSPECTION SEC.
j®
NUMBER
REV
4015/96
PAGE OF
APPROVED BY
/--'1 CITY HALL FRIDLEY 55432
612-571-3450
910-F15
JOB ADDRESS
I LEGAL
LOT NO.
BLOCK
TRACT OR ADDITION
SEE ATTACHED
DESCR.
I 2
3 Innsbruck
Villages
SHEET
2 PROPERTY OWNER MAIL ADDRESS
ZIP PHONE
Bob S encer 5656 West Bavarian Pass NE
571-2691
3 CONTRACTOR MAIL ADDRESS
ZIP PHONE LICENSE NO.
Columbus Exteriors Inc 2131 111 Ln NW, Coon RqpjdR, WIN
55-433 868-
4 ARCHITECT OR DESIGNER MAIL ADDRESS
ZIP PHONE LICENSE NO.
5 ENGINEER MAIL ADDRESS
ZIP PHONE LICENSE NO
6 USE OF BUILDING
Residential
7 CLASS OF WORK
❑ NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE
8 DESCRIBE WORK
Reside Townhouse; Soffit/Fascia
9 CHANGE OF USE FROM TO
STIPULATIONS
Install ventilation per State Building Code.
TYPE OF CONST.
OCCUPANCY GROUP
OCCUPANCY LOAD
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
ZONING
SQ. FT.
CU. FT
AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION
OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT
ANY TIME AFTER WORK IS COMMENCED.
NO. DWLG. UNITS
OFFSTREET PARKING
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
1
ISTALLS GARAGES
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
VALUATION
SURTAX
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMI'1�
00
.60
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE T
PERMIT FEE
SAC CHARGE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON-
$112.25
STRUCTION OR THE PERFORMANCE OF CONSTRUCTION
Fire SC $5.20
PLAN CHECK FEE
TOTAL FEE
License SC
$5,90
1 $125.05
SIGNAT RE 6FCONTRACTORORAUTHORIZEDAGENT IDATEI
WHEN PROPER ALI DATED THIS IS YOUR PERMIT
"BLD
fGY
SIGNATUREOF OWNERUF OWNERSUILDERI IDATEI
INSP
PATE
ADDN [ } CITY OF FRIDDLEY
.ALTER [d
SINGLE FAMILY AND DUPLEXES R-1 AND R-2
Building Permit Application
ConstructionAddress:
Legal Description:
West Bavarian
r,rrecuve sl i/yo
ass
Owner Name & Address: -5we't C- 0 -,,-
Tel. #j�
Contractor: Columbus Exteriors, inc-MNLICENSE# 3509
Address: 2131 111th In NW, Coon Rapids, MN 55433 Tel.#8
_68_9195
Attach to this application, a Cerfficate of Survey of the
lot, with the proposed construction drawn on it to scale.
LIVING ARFA: length Width Height Sq. Ft.
GARAGE AREA: Length Width Height Sq. Ft.
DECK AREA: Length Width Hgt/Ground Sq. Ft.
OTHER: Vinyl siding Aluminum trim
Corner Lot [ ] Inside Lot [ Ft. Yd Setback Side Yard Setbacks
Type of Construction: Estimated Cost:
Approx. Completion Date:
(Cost on Back)
Driveway Curb Cut Width Needed: Ft. + 6 Ft - Ft x $ _ $
DATE: ~-/ %'� APPLICANT: Tel. (- 7
Permit Fee
Fire Surcharge
State Surcharge
SAC Charge
License Surcharge
Driveway Escrow
Erosion Control
Park Fee
Sewer Main Charge
TOTAL
iTIPULATIONS:
CITY USE ONLY
Fee Schedule on Reverse Side
.001 of Permit Valuation WIWI%,)
$.501$1,000 Valuation
$moi per SAC Unit
$5.00 (State Licensed Residential Contractors)
Alt. "A" or Alt. "B" Above
$450.00 Conservation Plan Review
Fee Determined by Engineering
Agmement Necessary [ ] Not Necessary [ ]
SuB.,ECT
PERMIT N_0_
City of Fridley
?` 14 8
AT THE TOP OF THE TWINS
BUILDING PERMIT
f
RECEIPT NO.
COMMUNITY DEVELOPMENT DIV.
L
r 1 PROTECTIVE INSPECTION SEC.
i
f�
I �
_
CITY HALL FRIDLEY 55432
NUMBER
REVDATE
PAGE OF
APPROVED BY
j 612-571-3450
910-F15
5/7/96
JOB ADDRESS
See Below
1 LEGAL
LOT NO.
BLOCK
TRACT OR ADDITION SEE ATTACHED
DESCR.
Variou
SHEET
2 PROPERTYOWNER MAIL ADDRESS ZIP PHONE
Various
3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO
Columbus Exteriors Inc 2131 Ill Ln, Cnon Rapids MN 99431 969-
4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO
5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO
6 USE OF BUILDING
Townhouses
7 CLASS OF WORK
❑ NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE
8 DESCRIBE WORK
Reside 44 Units (11 Buildings)
9 CHANGEOFUSEFROM TO
STIPULATIONS
5600,5602,5604,5606 West Ba v Jan Pass; 5601,5603,5605,5607 West
Bavarian Pass; 5610,5612,5614,5616 est-$e�ae#ee-Fess; 5620,5622,5624,5626 West
Bavarian Pass; 5620,5622,5624,5626 North Innsbruck Ct; 1521,1523,1525,1527
Trapp Court; 5650,5652,5654,56 West Bavarian Pass; 5660,5662,5664,5666 West
Bavarian Pass; 5661,5653,5655,5657 West Bavarian Pass; 5671,5673,5675,5677 West
Bavarian Pass; and 5681,5683,5685,5687 West Bavarian Pass
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
TYPE OF CONST.
OCCUPANCY GROUP
OCCUPANCYLOAD
VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
ZONING
SO. FT.
CU. FT.
AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION
OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT
ANY TIME AFTER WORK IS COMMENCED.
NO. DWLG. UNITS
OFFSTREET PARKING
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
44
STALLS GARAGES
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
VALUATION
SURTAX
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT
$228,800
$114.40
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PERMIT FEE
SAC CHARGE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON-
$1,532.25
Fire SC $228.80
STRUCTION R THE PERFORMANCE OF CONSTRUCTION.
PLAN CHECK FEE
TOTAL FEE
License SC $5.00
$1,880.45
SI OF CONTRACTOR OR AUTHORIZED AGENT (DATEI
WHEN PROPERLY IDATED THIS IS YOUR PERMIT
( i
&GNATURE OF OWNERUF OWNER BUILDER( (DATEI
BLDG SP ',A It
..
- -- -
SUBJECT
TYPE OF CONST.
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
City ®f Fridley
SURTAX
THIS.PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
3 0 7 4 6
AUTHORIZED IS NOT COMMENCED WITHIN 80 DAYS, OR IF CONSTRUCTION
AT THE TOP OF THE TWINS
BUILDING
PERMIT
ANY TIME AFTER WORK IS COMMENCED.
NO DWLG. UNITS
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
FEE
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
ft -COPT NO.
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
COMMUNITY DEVELOPMENT DIV.
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT
$1,748
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PERMIT FEE
r PROTECTIVE INSPECTION SEC.
ST RUCTI OR THE RFORMANCE OF CONSTRUCTION
$63.15
OBJ
1 1 �•"1 CITY HALL FRIDLEY 55432
NUMBER
REV
DATE
t oOf.
PAGE OF
APPROVED By
612-571-3450
910415
J3/17/00
/ /
JOB ADDRESS ' °°5650, 5652, 56.54, 5656 West Bavarian Pass NE
11' LEGALLOT
NO.
BLOCK
TRACT OR ADDITION
SEE ATTACHED
DESCR.
•1-4
3
1 Innsbruck Villages
SHEET
2 PROPERTY OWNER MAIL ADDRES$
ZIP PHONE
3 CONTRACTOR MAIL ADDRESS
ZIP PHONE
LICENSE NO
Stock Roofing Inc. 3840 205 Ln Anoka MN 55303
213-1455
3112
4 ARCHITECT OR DESIGNER MAIL ADDRESS
ZIP PHONE
LICENSE NO.
S ENGINEER MAILADDRESS
ZIP PHONE'
LICENSE NO
A ° B t' USE OF'BUILDING
Reside
7 CLASS OF WORK
8 DESCRIBE WORK
Reroof
Lal Townhouse Garage
O NEW O ADDITION
9 CHANGE OF USE FROM
STIPULATIONS
O ALTERATION J3 REPAIR ❑ MOVE ❑ REMOVE
Buildine (20 SO Tear -off
TO---
SEPARATE
OS-=
iDAM
OCCUPANCY GROUP IOCCUPANCYLOAD
SO. FT
CU FT.
TYPE OF CONST.
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
VENTILATING OR AIR CONDITIONING
SURTAX
THIS.PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
ZONING
AUTHORIZED IS NOT COMMENCED WITHIN 80 DAYS, OR IF CONSTRUCTION
OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT
ANY TIME AFTER WORK IS COMMENCED.
NO DWLG. UNITS
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
FEE
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
VALUATION
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
VALID
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT
$1,748
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PERMIT FEE
PROVISIONS OF ANY OT RST TE OR LOCAL LAW REGULATING CON-
ST RUCTI OR THE RFORMANCE OF CONSTRUCTION
$63.15
OBJ
PLAN CHECK F E
Licen
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT iOATE�
t oOf.
iDAM
OCCUPANCY GROUP IOCCUPANCYLOAD
SO. FT
CU FT.
OFfSTREET PARKING
STALLS GARAGES
SURTAX
.87
SAC RGE
F e SC $1.75
FEE
0
20.77
VALID
THIS IS YOUR PERMIT
CITY OF FRIDLEY INSPECTION DIViSION
6431 University Ave NE
Fridley, MN 55432 APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION,
763.572-3604 REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES
RATE SCHEDULE
Residential
Furnace Shell and Duct Work, Burner -
Also Replacement Furnace
(Side Vent - Fill Out Back)
Gas Piping (Needed with new furnace,
but not replacement)
Gas Range
Gas Dryer
*Air Conditioning - All Sizes
All Others/Repairs & Alterations (LIST ON BACK)
1% of Value of Appliance or Work
Commercial/Industrial
1.25% of Value of Appliance or Work
Effective On January 1, 200*1
JOB ADDRESS 56-56 CAJ, &4L 'g/()
OWNER9®,3P
Rate TOTAL
BUILDING USED AS
$ 30.00 �
ESTIMATED COST "< ���• �® PERMIT.NO.���
$ 10.00 $
DESCRIPTION OF FURNACE AND OR BURNER
$ 10.00 $
No. of Heating Units_ Circle One (Steam) (Hot Water) arm Air))
$ 10.00 $ Trade Name % 6z�- � Size No.
19 BTU 60,000HP EDR
25.00 $ Fuel ,0S Total Connected Load
State Surcharge
TOTAL FEE
MINIMUM FEE FOR ANY HEATING/COOLING/VENTILATION
REFRIGERATION/AIR CONDITIONING PERMIT IS $25.00
PLUS THE $.50 STATE SURCHARGE
REINSPECTION FEE $47.00/Hr
*Air Conditioners can not be placed in a side yard without
written permission from adjoining property owner.
Burner Trade Name Size No.
$ BTU HP EDR
$ The undersigned hereby makes application for a permit for the work herein
specified agreeing to do all work in strict accordance with the City Codes an
$ .50 rulings of the Building Division, and hereby declares that all the facts and
$SS, So representations stated in this application are true and correct.
DATE
HEATING CO A45 sA) krZ 7-t '*%
Signed _/r�ic.et_ 1 TEL # 1�G/� S
1
Approved B Rough -In Date Final Date
BACK SIDE MUST BE FILLED IN ON VENT SIZE, VENT CONNECTORS
AND COMBUSTION AIR VERIFICATION
COMMON VENT VENT CONNECTOR AND COMBUSTION AIR VERIFICATION
When replacing an existing furance, the undersigned hereby verifies that the
venting has been examined and is free from rust, deterioration, obstructions,
and is securely supported and firestopped where required. Yes No ( )
The venting system is plastic/PVC and meets all current codes and manufacturer
specifications including sizing, length, number of elbows and termination. Yes No ( )
The undersigned also verifies that the replacement unit is a listed assembly
and meets the current codes and manufacturer's specifications. This does
include AGA-GAMA Category I Central Furnace Venting Tables for fan
assisted and natural draft appliances. YesV No ( )
The existing combustion air is sized and installed to meet the current codes
and manufacturer's specifications.
Yes ( ) No ( )
When required to install a new combustion air, it will be sized and installed
to meet the current codes and manufacturer's specifications.
Yes ( ) No ( )
When installing a new venting system, the undersigned hereby verifies that
it is a listed assembly and meets the current codes and manufacturer's
specifications. This does include AGA-GAMA Category I Central Furnace
Venting Tables for fan assisted and natural draft appliances.
Yes( ) No( )
Is the common vent and vent connectors sized and installed correctly after
an appliance has been removed from the common vent and vented
separately as per current codes.
Yes( )No( )
Appliance Type and Size/Common Vent and Vent Connector Information
Appliance #1 Type Au P- AC F BTU Input 6 ®; OOD Fan Assisted or Nat FFA '45!ir5 r�-6
Appliance #2 Type BTU Input IX, 61-00 Fan Assisted or Nat
Appliance #3 Type BTU Input Fan Assisted or Nat
Total Appliances Total Btu Input
Common Vent Type Vent Height Diameter inches
Appliance #1 Vent Connector Height ft Length ft Diameter in Type
Appliance #2 Vent Connector Height ft Length ft Diameter in Type
Appliance #3 Vent Connector Height ft Length ft Diameter in Type
ALTERATIONS: (Describe) -
f/JSv GiZL 7iz��
+ A r -L Colo nT7-xc9/JE�c
HEATING CO: Z 7 � 9' -91C
Signed By: Date
C[NOE
FRIDLEY
FRIDLEY MUNICIPAL CENTER • 6431 UNIVERSITY AVE. N.E. FRIDLEY, MN 55432 • (763) 571-3450 • FAX (763) 571-1287
January 18, 2002
Mr. Robert Spencer
5656 West Bavarian Pass NE
Fridley, MN 55432
Re: Final Inspection at 5656 West Bavarian Pass NE
Contractor: Krinkie Heating & Air Conditioning
Dear Mr. Spencer:
A mechanical permit was issued on July 12, 2001 to install a furnace and an air
conditioner at your address. According to the 1991 Uniform Mechanical Code a final
inspection shall be conducted on the work authorized by this permit. As of this date,
no inspection has been called for.
The permit fee that was paid covers the inspection to make sure the work was
completed according to the Codes. We will keep your permit open for another 30
days and if we do not hear from you within this time to set up the inspection, we will
mark the permit "no inspection called for" and no further action will be taken.
To set up the inspection or to have any questions answered, please contact the
Building Inspection Division at (763) 572-3604.
Sincerely,
DJ/mh