Loading...
PRE 2010 DOCS0 Village of Fridley, Minn. BUILDING PERMIT 40 N? 804 Office of ]INSPECTOR OF BUILDINGS Owned' Architect Fridley, Minn., Builder LOCATION OF BUILDING NO. T_U .I,e B —Part of Lot Lot Block Addition or Sub -Division DESCRIPTION OF BUILDING Front ± -- Depth _-::�;�j Height— Stories —.4/— Manner of Construction To be used as To be complete Estimated Cqst_,' ti Permit to hereby granted to 4= (iwl:, _Z­1=_.q.r-,.*' the bu1lding'_L'r— described In the above statement. This permit is granted upon the express condition that the person to whom it is granted, and his agents, employees and workmen, in all the work done in, around and upon said building, or any part thereof, shall conform In all respects to the ordi- nances of Fridley, Minn., regarding the construction, alteration, maintenance, repair and moving of buildings within the city limits, and this permit may be revoked at any time upon violation of any of the provisions of said ordinances. AGREEAMNT AND SWORN STATEMENT In consideration of the issue and delivery to me by the Inspector of Buildings of Fridley of the above permit, I hereby agree to do the proposed work in accordance with the description above set forth and according to the provisions of the ordinances of Fridley, and, being first duly sworn, I hereby state and say that the facts stated by me and contained in the above permit are true as therein stated. Subscribed and sworn to before me at Fridley, Afinnesota, _Js day 0 0 2 CV ��-6 From: unknown Page: 2/2 Date: 8/17/2006 3:48.40 PM •••" `-"" •• VI ri mmy IV. VJ I'VMJ' JI I roves. uN LAM= VI iIIl.WV V,W..•17 Effective 1/1/04 CITY OF FRIDLEY - MOVMG [ i WRECKING r APPLICATION 6431 University Ave NE Fridloy MN 55932 (763) 572-3604 FAX (763) 571-1287 Job Address: 44&- 40Q _ Legal DescripL iun: Owner & Address: _ _ �.:� --� ai. Contrartor:_� . ,P _ Tel. #i Address: state l V License # DESCRIPTION OF BUH.DING HOUSE: Length Width _ _ Height _ Sq: FL. Cu. Ft. GARAGE:I.ength Width HeighL E'W Sq. Ft. Cu. Ft. OTHER: Leng Lfi EstiniaLed Cast $ Water Bill Paid: Moving Route: Width Height Sq. FL. Cu. FL. ONE AT 651-484-0002 Yes [ 1 or Collect [$ Appzox. Completion Date LITY LOCATION STRUCTURE. ] Signature The undersigned hereby makes application for a permit to wreck/move the building described above, agreeing to do all work in strict accordance with the City Ordinances and rulings of the Building Division, and the State Code which requires any water well on the property to be sealed by a State licensed water well driller, and hereby declares that all facts and representations stated in this application are true and correct. ALL DEMOLITON DEBRIS, INCLUDING FOUNDATION & SLAB, SIIALL BE REMOVED FROM SITE. ye --71, Date Signature Jul 30 06 11:25p Robert 952-895-9628 3uilding AND MATERIALS: o-� F Ll7 LDING (USING THE 199- U.B C FEE SCHEDULE) /7 D b- F® TYPE Permit No.: Inspections . a5 E tre Back Page for Fee Schedule 0%, of Building Permit Fee Kt D RESIDENT [AL APPLICATION '1 .0' times the total jot. valuation Received By: 763-572-3604 License Surcharge $ CITY (:)'.IF FRIDLEY SAC Charge $ Date Recd: )ATE l OfO YOUR E- df • L ADDRESS �� �1 v -� rv.a t. / D X51 �i t�r �-�' P� ;ITEADDRESS Zi n�v1 g� �` S"{ .I�✓� —_—• F're Determined by Engineering "HIS APPLICANT IS: UA VAER OCONTRAC' f 01: Total Due $ � PROPERTY OWNER! NAME: �O� 4 -✓-"4 THIS IS AN APPLICATIOI I FOR A PERMIT -NOT VALID UNTIL PROCESSED TENANT ADDRESS: kk L -*� �" �' �.t iZ%'c CIT'l t ! t� STATFl^_YZ1P„ pffmit and yrork is no to s:art without a perrr.it; that the work will be in accordance with the approved PHONE: 2 b 311-5 ? t - 3 lt� j ---• r res and�ppr: v� t Fplans. rh_ CONTRACTOR NAME: --` STATE LICENSE # EXP DATE SUBMIT A COPY OF YOUR STATE LICENSE ADDRESS: —_—. CITY STATE ZIP WITH APPLICATION PHO FAX GLE FAMILY/NEW CONSTR1 L7°ioid SEM PROPERTY TYPE 0 TWO FAMILYINEW CONSTRUC•I ION STORIES PERMIT TYPE D ADDITION C au.IL`-.GE/SHED O WINDOWS 0 BASEMENT FINISH CR(i�l 0 DRAIN TILE 0 DECK 0 SI A7.0 THER ' l C SVIMJMING POOL M114EW 1: ADDITION TYPE OF WORK: O MAINTENANCE/REPAIR C i RI i N: )DELING DESCRIBE WORK BEING DONE: 512E OF IMPROVEMENT LE:1GTf IVIIDTHi . �, EIEIGHT -' ''. S . Ft. oO OFING ❑ HOUSE Or.: �— VUM$ER OF SQUARES O HOUSE & 3,61L0E BASEMENT REMODELING SUBMIT: GARAGES 0 ATTACHE ) GARAGE I. 2. Existing Floor Plan Proposed flour plan PROPOSED SIZE: E3DE TACHE. ) GA:;.AGE 3. List of structural members to be used PROPOSED HEIGHT: SIDING FOR NEW CONSTRUCTION INCLUDING DECKS, i 3 Vinyl 0So8=tt ADDITIONS. & PORCHES SUBMIT: • Aluminum 0 Trim I, Site Pian/Survey showing the existing structures • Other ❑ Fascia and proposed project 2. Two sets of construction plans WI1�TfdOWS 3. Energy Calculations IN E)USTING OPENINGS OYes ONo LOCATION OF WD- D("%.i DR FOR NEW OPENINGS -DESCRIBE SIZE OF —_—• _ OPENING CHANGES & TYPE OF WINDOW TO BE INSTALLED NUNS R OF WINDOWS ALL FEES ARE BASED ON VALUATION, INC LUIIING THE COST OF LABOR AND MATERIALS: (USING THE 199- U.B C FEE SCHEDULE) /7 D b- F® TYPE TOTAL JOB VALUATION $ OCCUPANCY Permit Fee $ Plan Review $ . a5 E tre Back Page for Fee Schedule 0%, of Building Permit Fee Kt D Fire Surcharge $ '1 .0' times the total jot. valuation Surcharge $ .001; 5 x Permit Valuation Minimum $.50YVP(� License Surcharge $ g:i.I; 0 (State Licensed :2esidential Contractors) � SAC Charge $ S :: S.iO per SAC Unit (flans to MWCC for determination) Club Cut Escrow $ _ft + b ft = ft x $21 = $ Erosion Control $ $45l] Conservation Plan Review Park Fee $ F're Determined by Engineering Sewer Main Charge $ ELgrmment necessary ( ) Non Necessary ( ) Total Due $ � �� _� Make checks payable to: City of Fridley Attach Stipulations THIS IS AN APPLICATIOI I FOR A PERMIT -NOT VALID UNTIL PROCESSED I hereby apply for a building permit and I acknowledge that 'be information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of I ri=le y and with the Minnesota Construction Codes; that I understand this is not a permit but only an application fora pffmit and yrork is no to s:art without a perrr.it; that the work will be in accordance with the approved c cI plan in the case of all Worh re r res and�ppr: v� t Fplans. rh_ ---. �WHTESIGNATUREOFAPPLICAR ��� �� �������-�,�y �r �� i .4L Kolden Engineering May 19, 2003 To Whom It May Concern: ECOPY RE: Allan Block "Standardized Manual for Pre -Engineered Retaining Walls" I have reviewed Allan Block "Standardized Manual" wall designs and installation procedures enclosed with this letter, and certify the designs and design methodologies presented therein, with the following limitations: 1. The Allan Block segmental retaining wall shall be installed in strict compliance with the building codes, and have legal permits and inspections as required by the local building department. Certification of proper installation shall be by the permit holder, and is beyond the scope of this document. Proper installation is otherwise assumed, and is a condition of use of this certification. 2. The system used shall be exclusively the Allan Block Retaining Wall Systems addressed in the attached manual. 3. The retaining wall shall be installed in strict compliance to the Allan Block Installation Guides, fully satisfying all installation requirements defined therein, including the specifications or provisions delineated in the "Standardized Manual Procedure," the General Notes and the Drainage Notes. 4. The soil types and specific site conditions shall be within the limitations defined in the manual, including slopes above the wall or live load surcharge. No appreciable slope whatsoever is permitted at the foot of the wall. If tiered walls are used, the foot of the upper wall shall not be less than two times the height of the lower wall back from the top of the lower wall. In all cases, the foundation, infill and retained soils shall have a friction angle of not less than 27 degrees, and have a unit weight of no greater than 120 pounds per cubic foot. The maximum slope above the wall or the maximum surcharge is as indicated in the manual. Alternatively, the maximum live load surcharge on a level surface above the wall shall not exceed 125 pounds per square foot. In no case shall sloping soil surcharges be combined with the live load surcharges; that is, both conditions existing concurrently are beyond the scope of the manual and this evaluation letter. Appropriate site and soil analysis shall be performed by others to verify the parameters fall within the limitations set forth in the design manual. Any wall design that has one or more specific conditions that are outside the limitations given here and in the manual is beyond the scope of this certification. 5. Sufficient site drainage shall be provided, as designed by others, but sufficient to prevent the build up of hydrostatic pressure on the wall at any time during the fiill service life of the structure; and in full compliance to the Allan Block design criteria. Certification of site drainage and water management shall be made by the permit holder, and is a condition of this certification. Kolden Engineering 17475 Iceland Trail Lakeville, MN 55044 PH: 952-201-5346 FAX: 952-892-7038 Allan Block "Standardized Manual for Pre -Engineered Retaining Walls Page 2 of 2 6. Where required in the manual, the geogrid shall be the AB Reinforcement Grid, or approved equal. 7. Wall heights greater than six feet are beyond the scope of both the Allan Block manual and this certification letter. 8. Global stability and seismic design are not considered, and are beyond the scope of this certification letter. While global stability and seismic design are probably not going to be a governing issue for the walls installed within the limitations of the Allan Block manual, it is impossible to predict the variables of every conceivable application. Therefore, the permit holder is advised to consult an appropriate design professional if there is any doubt about the conditions of a wall design for any specific job sit, with respect to global stability or seismic design requirements. The evaluation of the Allan Block design manual and wall designs specified therein was conducted in accordance with the design criteria defined in the Allan Block Engineering Manual (Reference: ABENG.M5.0196). In my opinion, the retaining wall designs specified therein, used strictly within the specific parameters indicated, comply with the design criteria indicated, which I deem is acceptable under the provisions of the building code. I hereby certify that this plan, specification, or report was prepared by me or under my direct gupery nand th t I a ardul_v Registered Professional Engineer under the laws of the State of Thomas A. Kolden, P.E. Minnesota Registration No. 24080 Kolden Engineering 17475 Iceland Trail Lakeville, MN 55044 PH: 952-201-5346 FAX: 952-892-7038 Note: An Allan Block Retaining Wall Systems — Standardized Manual for Pre -Engineered Retaining walls must be on file and accepted by the local municipality for this form to be utilized. This Standardized Manual must be approved, verified and stamped by a local engineer. PROCEDURE: Refer to the AB Standardized Manual on file with the Municipality for complete directions. Determine the required wall height and geometry. • The wall height (H) represents the distance from the ground surface at the base of the wall to the top of the wall. • Identify what the condition above the wall is. The condition above the wall can be one of three things. Condition I is for a level slope above the wall with no surcharge. Condition II is for a level slope with a uniform live load surcharge of 125 PSF (generally a load associated with passenger vehicles). Condition III is for a sloped backfill with no surcharge. 2. Determine the soil classification that is predominant at the site using the Uniform Building Code (UBC). The Standardized Manual is limited to two soil conditions, which are Sandy Soil or Clayey Soil. 3. Based on the specific requirements for the wall (Wall Height, Condition, UBC Soil Type and Allan Block Retaining Wall block type) determine the design. • Geogrid: Determine if geogrid is needed. If the wall height is less than the maximum Gravity Wall heights and the additional conditions are met the retaining wall can be built without geogrid reinforcement. The specifications for each Allan Block Retaining Wall block provided Gravity Wall heights.. • Geogrid length, L: Geogrid length is measured from the front face of the Allan Block units to the back of the geogrid length. Geogrid Layers: The total number of geogrid layers needed. Geogrid Position: The location of each geogrid layer above the base. 4. Submit the design and this completed form, which references the AB Standardized Manual to the Building Department if required. • Determine what the building department requirements are. • Identify if the wall falls_within those requirements. • The Allan Block Installation Guide for Allan Blwk Retaining Walls (when geogrid is needed) or the Allan Block Installation Guide for Allan Block Landscape Walls (when geogrid is not needed). • Any additional documents requested by the building department. LIlV DATIONS: This manual does not consider the following special considerations. If any of them are present on the site this manual should not be used without consulting with a qualified engineer. • Noticeable water within the soil or large amounts of surface runoff directed at the retaining wall. • A slope greater than 4H:1 V descending from the front toe of the wall. • Walls built in a terraced application where their space apart is less than twice the lower walls individual wall height. • Any wall higher than 6 f , supporting a slope steeper than specified or heavy truck 4.nd highway loading. • Requirements to include seismic loading in the calculations. • Requirements to analyze the site for global stability. DOC # D1133 Last printed 7/7003 11:12 AM ALLAN BLOCK RETAINING WALL SYSTEMS STANDARDIZED MANUAL FOR PRE-ENGINEERED RETAINING WALLS The following information is provided for construction of retaining walls up to 6 feet in height Varying soil strengths and loading conditions are addressed. The pre- engineered walls on the following pages are designed solely for the Allan Block Retaining Wall System, and are based on the Allan Block design methodology. The following Allan Block Retaining Wall blocks are included in this manual. AB STONE • • ' . ' 2,Y Unit Size: 11 7/ 8"d x 7 3/4"h x 17 5/8"w Weight: 75 lbs. (approximately) Coverage: 0.95 sq. ft. per unit Notes: Gravity Wall (no geogrid) maximum height is 5.5 ft. The following conditions must be true or geogrid reinforcement is required according to the pre-engineered tables for AB Stones. 1. Level slope and no surcharge above the wall 2. Sandy Soil - UBC soil type 3 or better. UBC soil type 4 and 5 requires geogrid reinforcement. 000 Unit Size: 11 7/ 8"d x 7 3/4"h x 17 5/8"w Weight: 75 lbs. (approximately) Ceva.95 s . ft. per unit Notes: Gravity Wall (no geogrid) maximum height is 4.0 ft. The following conditions must be true or geogrid reinforcement is required according to the pre-engineered tables for AB Classics, AB Rocks, or Dover. 1. Level slope and no surcharge above the wall 2. Sandy Soil - UBC soil type 3 or better. UBC soil type 4 and 5 requires geogrid reinforcement. AB JUNIOR OR PALERMO AB LITE STONES OR BARCELONA sk :wk�T Y a 1 !E Nn 7".&Atlix 3' Page 2 Unit Size: 9 1/2"d x 7 3/4"h x 8 1/2"w Weight 35 lbs. (approximately) Coverage: 0.46 sq. ft per unit Notes: Gravity Wall (no geogrid) maximum height is 4.0 ft. The following conditions must be true or geogrid reinforcement is required according to the pre- engineered tables for AB Juniors or Palermo. 1. Level slope and no surcharge above the wall 2. Sandy Soil - UBC soil type 3 or better. UBC soil type 4 and 5 requires geogrid reinforcement. Unit Size: 11 7/ 8"d x 3 7/8"h x 17 5/8"w Weight 35 lbs. (approximately) Coverage: 0.48 sq. ft. per unit Notes: Gravity Wall (no geogrid) maximum height is 4.0 ft The' following conditions must be true or geogrid reinforcement is required according to the pre-engineered tables for AB Lite Stones or Barcelona. 1. Level slope and no surcharge above the wall 2. Sandy Soil - UBC soil type 3 or better. UBC soil type 4 and 5 requires geogrid reinforcement. Page 3 STANDARDIZED MANUAL PROCEDURE 1. Determine the required wall height and geometry. • The wall height (H) represents the distance from the ground surface at the base of the wall to the top of the wall. • Identify what the condition above the wall is. The condition above the wall can be one of three things. Condition I is for a level slope above the wall with no surcharge. Condition II is for a level slope with a uniform live load surcharge of 125 PSF (generally a load associated with passenger vehicles). Condition III is for a sloped backfill with no surcharge. Condition I: Condition II: Condition III: Level Slope. No Surcharge Level Slope 125 PSF Surcharge Slope Backfill 3:1 Maximum No Surcharge 2. Determine the soil classification that is predominant at the'site using the Uniform Building Code (UBC). Sandy Soil - Soil Twe 3 This soil type includes Sandy Gravel and/or Gravel (GW and GP) Clay Soil - Soil Type 4/5 This soil type includes Clay, Sandy Clay, Silty Clay, and Clayey Silt (CL, ML, MH, and CH) And/or Sand, Silty Sand, Clayey Sand, Silty Gravel, and Clayey Gravel (SW, SP, SM, SC, GM, and GC) Note: When using this standardized manual to obtain building permits it may be necessary to document the UBC soil type. Assistance from a licensed engineer in the form of a letter identifying the specific soil may be helpful, however a complete soils report and investigation should not be necessary. In many residential developments a soils investigation is available from previous property development. The developer, building department or public works department may have these reports on file. Page 4 3. Based on the specific requirements for the wall (Wall Height, Condition, UBC Soil Type and Allan Block Retaining Wall block type) determine the design. • Geogrid: Determine if geogrid is needed. If the wall height is less than the maximum Gravity Wall heights and the additional conditions are met the retaining wall can be built without geogrid reinforcement The specifications for each Allan Block Retaining Wall block provided Gravity Wall heights. • Geogrid length, L: Geogrid length is measured from the front face of the Allan Block units to the back of the geogrid length. • Geogrid Layers: The total number of geogrid layers needed. • Geogrid Position: The location of each geogrid layer above the base. 4. Submit the design to the Building Department if required. Determine what the building department requirements are. Identify if the wall falls within those requirements. If a building permit is required submit the following: v The Standardized Manual with the specific design that applies to the wall identified. The Allan Block Installation Guide for Allan Block Retaining Walls (when geogrid is needed) or the Allan Block Installation Guide for Allan Block Landscape Walls (when geogrid is not needed). Any additional documents requested by the building department 5. This manual does not consider the following special considerations. If any of them are present on the site this manual should not be used without consulting with a qualified engineer. Noticeable water within the soil or large amounts of surface runoff directed at the retaining wall. • A slope descending from the front toe of the wall. • Walls built in a terraced application where their space apart is less than twice the lower walls individual wall height • Any wall higher than 6 ft, supporting a slope steeper than specified or heavy truck and highway loading. Requirements to include seismic loading in the calculations. Requirements to analyze the site for global stability. ALLAN BLOCK TYPICAL SECTION The section below is a typical section of an Allan Block Retaining Wall. Various conditions are noted relative to the above the wall condition. Additionally, dimensions pertinent to the wall design are defined within the drawing. Figure 1: Allan Block Typical Section OPTIONAL ALLAN BLOCK CAPSTONE ALLAN BLOCK AB STONE, AB CLASSIC, AB ROCKS, AB JUNIOR OR AB LITE.. STONES BLOCK —� WALL HEIGHT, H 1 BLOCK TYPICAL T 6 in J_ ' p5F S�RCHPRGE 125 4 in DRAIN TILE VENTED TO DAYLIGHT GEOGRID REINFORCED BACKFILL Page 5 8 PCKF\L�- 5`OPEp M p,X�M�M 3� UNDISTURBED NATIVE SOIL I -WELL GRADED 3/4in GRANULAR DRAINAGE ROCK WITH LESS THAN 10% FINES LAYER #3 LENGTH --► LAYER #2 -GEOGRID REINFORCEMENT, 500 Ib/ft MINIMUM LONG TERM ALLOWABLE DESIGN STRENGTH, SEE DESIGN TABLES FOR GEIOGRID POSITION 4 in DRAIN TILE VENTED TO DAYLIGHT ALLAN BLOCK TYPICAL SECTION NOT TO SCALE AB STONES noun i�i%�'. MW Condition Condition 1: Table 1: SANDY SOIL UBC Soil Type 3 Condition 11: Page 6 Condition 111: Condition Above Wall Wall Height, ft Geogrid Length, ft Geogrid Position (# courses above base) Layer #1 Layer #2 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - - 4 - - 5 - - - - 6 4 1 1 3 5 7 II: 125 PSF Surcharge 3 - - - - - 4 - - _ - - 5 3 1 3 5 - 6 4 1 3 5 7 III: 3:1 Maximum Slope Above the Wall 3 - - - - - 4 - - - 5 - - - - - h 4 ^1 3 5 7 Table 2: CLAY SOIL -- UBC Soil Type 4/5 Condition Above Wall Wall Height, ft Geogrid Length, ft Geogrid Position (# courses above base) Layer #1 Layer #2 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 II: 125 PSF Surcharge 3 3 1 3 - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 III: 3:1 Maximum Slope Above the Wall 3 3 1 3 - - 4 3 1 3 - - 5 4 1 3 5 - 6 4 1 3 5 7 AB CLASSIC, AB ROCKS, and DOVER Page 7 Condition 1: Condition 11: Condition 111: Table 3: SANDY SOIL - UBC Soil Type 3 Condition Above Wall Wall Height; ft Geogrid Length, ft Geogrid Position (# courses above base) Layer #1 Layer #2 layer #3 layer #4 I: No Slope or Surcharge 3 - - - - - 4 - _ _ _ _. 5 3 1 3 5 - 6 4 1 3 5 7 II: 125 PSF Surcharge 3 - - - - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 III: 3:1 Ma)amum Slope Above the Wall 3 - - - - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 Table 4: CLAY SOIL — UBC Soil Type 4/5 Condition Above Wall Wall Height; ft Geogrid Length, k Geogrid Position (# courses above base) Layer #1Layer #2 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 If: 125 PSF Surcharge 3 3 1 3 - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 III: 3:1 Ma)amum Slope Above the Wall 3 3 1 3 - - 4 3 1 3 - - 5 4 .1 3 5 - 6 4 1 3 5 7 AB JUNIOR and PALERMO Page 8 noun NOs` V � V p%r Condition 1: Table 5: SANDY SOIL - UBC Soil Type 3 Condition 11: Condition 111: Condition Above Wall Wall Height, ft Geogrid Length, ft Geogrid Position (# courses above base) Layer #1 Layer #2 1 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - - 4 - - - - - 5 3 1 3 5 - 6 4 1 3 5 7 II: 125 PSF Surcharge 3 - - - - - 4 3 1 3 - - 5 3 1 3 5 - 6 4. 1 3 5 7 III: 3:1 Maximum Slope Above the Wall 3 - - - - - 4 31 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 Table 6: CLAY SOIL - UBC Soil Type 4/5 Con&tion Above Wall Wall Height, ft Geogrid Le ft Geogrid Position (# courses above base) Layer #1 Layer #2 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 II: 125 PSF Surcharge 3 3 1 3 - - 4 3 1 3 - - 5 3 1 3 5 - 6 4 1 3 5 7 III: 3:1 Maximum Slope Above the Wall 3 3 1 3 - - 4 3. 1 3 - - 5 4 1 3 5 - 6 4 1 3 5 7 Page 9 AB LITE STONES and BARCELONA Table 7: SANDY SOIL - UBC Soil Type 3 Condition 111: Condition Above Wall Wall Height, ft Geogrid Length, ft Geogrid Position (# courses above base) Layer #1 Layer #2 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - - 4 - _ - _ _ 5 3 1 2 6 10 - 6 4 2 1 6 1 10 1 14 II: 125 PSF Surcharge 3 - - - - 4 3 2 6 - - 5 3 2 6 10 - .6 4 2 6 10 14 III: 3:1 Ma)amum Slope Above the Wall 3 - - - - - 4 3 2 6 - - 5 3 2 6 10 - 6 4 2 6 10 14 Table 8: CLAY SOIL - UBC Soil Type 4/5 Condition Above Wall Wall Height, ft Geogrid Length, ft Geogrid Position (# courses above base) Layer #1 Layer #2 Layer #3 Layer #4 I: No Slope or Surcharge 3 - - - - - 4 3 2 6 - 53 2 6 10 - 6 4 2 6 1 10 14 II: 125 PSF Surcharge 3 3 2 6 - - 4 3 2 6 - - 5 3 2 6 10 - 6 4 2 6 10 14 III: 3:1 Ma)amum Slope Above the Wall 3 3 2 6 - - 4 3 2 6 - - 5 4 2 6 10 - 6 4 2 6 10 14 Page 10 GENERAL NOTES 1. All design tables in this manual have been constructed with the Allan Block design methodology, ABENGMAN1099. 2. Retaining wall units and installation must conform to the Allan Block Modular Retaining Wall Systems Specification Guidelines and the Geogrid Reinforcement Systems Specification Guidelines as published in the Allan Block Design Manual, ABENG.M11-99 and the AB SPEC BOOK, ABENG4-00. 3. All installation procedures must be in accordance with the Allan Block installation guidelines, ABINST.1-0600 or ABINST.2-0600. 4. Base trench must be excavated to undisturbed soil. Remove any unsuitable or unstable soils and replace with compacted structural fill. Do not over excavate for the base trench unless it is necessary to remove unsuitable or unstable soils. 5. Minimum embedment depth of base course is 1 in. per ft of wall height minimum for gravity walls (no geogrid). For all geogrid reinforced walls 1 block (8 in) should be buried. Geogrid Reinforcement must have a minimum Long Term Allowable Design Strength of 500 lb/ft EMBEDMENT DEPTH rza • . . FINISH GRADE. BELOW WALL � I � 4 in (100 mm) DRAIN TILE VENTED TO DAYLIGHT ALLAN BLOCK SECTION - EMBEDMENT DEPTH 6. Global stability and seismic loading are not considered in this design. It is the responsibility of the project owner to determine if local codes or conditions necessitate their inclusion in the wall structural analysis. 7. If the site conditions, soil conditions or water conditions vary from those listed in this manual a qualified engineer must be consulted to evaluate the conditions. 8. Reference documents are available at allanblock.com. Page 11 DRAINAGE NOTES 1. If water is encountered in the area of the wall during excavation or construction, a drainage system (chimney, composite or blanket) must be installed as directed by the geotechnical or site engineer. 4 in (100 mm) ----7�` -'— 4 In (100 mm) DRAIN TILE DRAIN TILE VENTED TO DAYLIGHT —/ 37. MINIMUM FALL VENTED TO DAYLIGHT 6 In (150 mm) MINIMUM ALLAN BLOCK TYPICAL SECTION — CHIMNEY DRAIN 2. Drain tile must be vented to daylight at the ends of the wall. If this is not possible vent the drain file to daylight through the wall face, above finish grade, at a minimum of 50 ft intervals. CUT NOTCH IN ALLAN BLOCK TO ALLOW FOR DRAM. TENDMZY 1D DRAIN PIPE \� u DR YARIMUE IRISE N O. -M OR DRAINAGE ROCK 025 In OF D< ORm/FFR1 EATER RIS 'a LESS THAN 109. FINES FINISH GRADE TO WELL GRADED GRANULAR 4 In (100 GIRD) DRAIN TILE THE WALL FACE WITH a VENTED THROUGH THE FACE AN IMPERVIOUS SOIL DRAINAGE RDCK 0.23 In to 13 in IS mm to 30 mm) H POSSIBLE ELEVATION ON 50 . :{;,." •. Ft (15 m) CENTERS MAXIMUM LESS THAN 106 FlNES 1 0.7 H 6 In (150 mm) MINIMUM \ BLANKET DRAM 4 in (100 mm) ----7�` -'— 4 In (100 mm) DRAIN TILE DRAIN TILE VENTED TO DAYLIGHT —/ 37. MINIMUM FALL VENTED TO DAYLIGHT 6 In (150 mm) MINIMUM ALLAN BLOCK TYPICAL SECTION — CHIMNEY DRAIN 2. Drain tile must be vented to daylight at the ends of the wall. If this is not possible vent the drain file to daylight through the wall face, above finish grade, at a minimum of 50 ft intervals. CUT NOTCH IN ALLAN BLOCK TO ALLOW FOR DRAIN PIPE WELL GRADED GRANULAR DRAINAGE ROCK 025 In TO IS In (5 mm TO 38 mm) 'a LESS THAN 109. FINES FINISH GRADE TO SLOPE AWAY FROM 4 In (100 GIRD) DRAIN TILE THE WALL FACE WITH a VENTED THROUGH THE FACE AN IMPERVIOUS SOIL OF THE WALL AT THE LOWEST OR SURFACE. POSSIBLE ELEVATION ON 50 . :{;,." •. Ft (15 m) CENTERS MAXIMUM LOW PERMEABILITY GRANULAR MATERIAL PLACED IN CORES OF THE ALLAN BLOCK AS WELL AS M THE INFILL SOIL - 3. Surface water must not be allowed to pond or be trapped in the area above or below the wall. Water must not be allowed to drain over the top of the wall. Establish final grade with a positive gradient away from the wall structure. . 4. Concentrations of surface water runoff should be managed by providing necessary structures, such as paved ditches, drainage swales, catch basins, etc. PER9EABLE CONCRETE' R ASPHALT LINMG I2 (100 mm) THICK Page 12 4 Im. (100 mm) VEGITATION OR EROTION CONTROL B Im. (200 mm) IMPERMEABLE SOIL ALLAN SLOCiG SECTION - SWALE DETAILS 5. All roof eaves near the wall must be guttered and discharged away from the wall. Gutters, downspouts and connections must have adequate capacity to carry storm water away from the wall. 6. Irrigation activities at the site should be done in a controlled and reasonable manner. S-X,a krrr__j5 N w NEW [ j CITY OF FRIDLEY Effective 1/1/2003 ADON (j 6431 University Ave NE, Fridley, MN 55432 (763) 57 -3604 Bldg Insp ALTER [ ] SINGLE FAMILY AND DUPLEXES R-1 AND R-2 (71 -12J�7 Fax BUILDING PERMIT APPLICATION /J� 1 U� Construction Address: Legal Description: Owner Name & Address: Contractor: SeA4Wp C15, MN LICENSE Address:� �� ia,�ria v (?�-1� �3 , S�R PZUJ -_5;� 11 Tel. LIVING AREA: GARAGE AREA: DECK AREA: OTHER: Attach to this Spp4cation, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF IMPROVEMENT Length Width I Height Sq. Ft. Q Length Width �® Height Sq. Ft. 4<0 Length Width Hgt/Ground Sq. Ft. ;Construction Type: Estimated Cost: $T Driveway Curb Cut Width Needed: Ft. + 6 Ft = Ft x :DATE:/ �, APPLICANT: Tel. #9Si ,A�6 33 Call (763) 572-3604 for Permit Fees if mailing in application. Fax to 63-579-1287 if using credit card and we will call you for card number. Permit Fee fire, Surcharge State Surcharge SAC Charge ;license Surcharge Curb Cut Escrow Erosion Control P -.a r_- 06-y.QA,5 Sewer Main Charge $ 5 lia5' $ 4.WD $ 'l�1 $ TOTAL $ LI L41.,-19 CITY USE ONLY - Fee Schedule on Reverse Side .001 of Permit Valuation (1110th%) $.50!$1,000 Valuation $1275 per SAC Unit $5.00 (State Licensed Residential Contractors) Alt. "A" or Alt. 'B" Above $450.00 Conservation Plan Review Fee Detennined by Engineering Agreement Necessary[ } Not Necessary[ PLOT PLAN 4 - Mr. Robert LeClaire 4624 3rd St. NE 71 Fridley, MN 55421 H763-571-2107 612-661-4918 LOT SIZE: X13( T "Ilk t --77 HOUSE SIZE: 11771! SQ. FT. CITY CROSS STREETS: --A T AND -T 44-- "4 DIRECTION LEGAL DESCRIPTION LOT: 4 - - ---- BLOCK: ADDITION: 14 .-� LOT SIZE: X13( T "Ilk t HOUSE SIZE: SQ. FT. CROSS STREETS: T AND 44-- "4 DIRECTION t SUSSEL GARAGES �12 � Manufactured Trusses ROOF: GABLE REVERSE GABLE HIP EAVE OVERHANG: RAKE OVERHANG: SEAL DOWN SHINGLES WITH PLYWOOD OR WAFERBOARD ROOF SHEATHING AND 15 LB. FELT. Roof Sheathing�� Seal Down Shingles 2" x 4" DbVTriple Top Plate NOTE: 1) Roof approved by Minnesota State Buliding Dept. as meeting Minnesota State Code Requirements of 40# snow load. RAFTERS: Trusses @ 24" O.C. STUDS: 2" x 4t316" O.C. WALL SHEATHING: SIDING C!EA-1 f � OVERHEAD DOOR HEADER: Double 2" x 12" or 2 - Micro Lams x 2"x 4" studs 2"x6" Treated Bottom Plate Sill Sealer 1 Row 6" Concrete Blocks 11 � SLAB: NOMINAL 4" RE-INFORCED CON( (t*'J Ice and Water Protection Trim 1"x4" Sub Fascia \ Fascia Soffit 3/4" Cove —2" x 4" Studs *--'Siding 5/8° Gyp. Shts. Only on Walls within 3' of interior lot Lines, Floor to Roof Shtg. 1/2" x 7" Anchor Bolt w/Re-Bar Tle To Slab 2" x 4" Treated Bottom Plate --•-•-•-•-•-•-•-•- - _ °f Above Grade I 8" �♦ Grade Form TT -077A Nge2of2 Figure 1. Recommended construction details for APA portal frame bracing without hold- ns MAX. HEIGHT 10' EXTENT OF HEADER A . y MIN. 3" X 11.28" NET HEADER L .� 8' TO 18' FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 1813 SINKER NAILS AT 3" O.C. TYP. 1000 LB STRAP OPPOSITE SHEATHING FASTEN SHEATHING TO HEADER WITH 8D COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWN AND 3" O.C. IN ALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP. WIDTH BASED ON 6:1 HEIGHT -TO -WIDTH RATIO: FOR 120" HEIGHT, MIN. WIDTH - 20", FOR 98" HEIGHT, MIN. WIDTH a 16", ETC. MIN. (2) 2x4 - MIN. (2) 2x4 FOR A PANEL SPLICE (IF NEEDED), PANEL EDGES SHALL BE 1 BLOCKED, AND OCCUR WITHIN 24" OF MID -HEIGHT. ONE ROW OF TYP. SHEATHING -TO -FRAMING NAILING 19 REQUIRED. IF 2X4 BLOCKING IS USED, THE 2X4'8 MUST BE NAILED TOGETHER WITH 318D SINKERS MIN. 2"X2"X3/18" PLATE WASHER _ ANCHOR SOLT PER CODE U SHEATHING FILLER IF NEEDED 16D SINKER NAILS IN 2 ROWS ® 3" O.C. 1000 LB HEADER STRAP 318" MIN. THICKNESS WOOD STRUCTURALPANEL SHEATHING MIN. 2x4 FRAMING TYP. SECTIONA-A,,,,, 7011 South 19th Street. P.O. Box 11700. Tacoma, WA 98411-0700 Telephone: (283) 888-8800 • Fax Number. (283) 888-7265 FRAMING FOR 16D NAIL ® 24 GYPSUM WALL IN. O.C. BOARD. (OPTIONAL) BD NAIL ® a IN. O.C. IN ALL PANEL EDGES NOT PART OF PORTAL FRAME PORTAL FRAME WALL AUG -21-2006 07:59 EBCO 9529390543 P.03i06 , vvL� wNs� mygl eWNYf NY � m ME \if is $ �o�W opi� Z Q OW O Q fYC �C '• d mM� oPSi p&r 0000 �N •• Mu" y 3 CL •�]�.. YYY wiuioiv p� mmlp .t W .i NNNNa RN cam t�r AA �I pF 000� oeeee "10 O �Yi 7.i� C �l1{� .%ip�•Ni n'muaa m ww -ap DO P vi R ! r � � W D If N 1.!., .n r 7Y, • .Y El 1Od�i {�iB `e�0 '1i� Oe M :oma`^''-e.$m �E L"' �m P•µ�Y.®M.�.. j A W S 'Y � �• S.�i.$ Q 0104 9%011 X m •C OA13-A"� 11 Omtfm M�. mO W6•a N m M.'� V� Vi Ge ppj1 !(CSI, ppp��I a b oslip{� "�+ ami •m•I 's 8 �; r N� .7 a W N �~ 9 ,�yrr �C On, ii a'• o '43 p1 to w m 94 M act a, m ld S; ° N a r•II P a n -h Nm3e,T"}�.2y 1l o Qg mNllno b* 19 r �gS Rem �z� �b 1 NvbN•C C . N a —e � M O 5�w'�'11'Q mC b N w H Hma .■ c 06CL (0 Hm4 zg a�=� •�gI Wqt Ww Cyd �nyj .n n nw otR p p ID O m b N W41COGtl n ?�a� 4 N 1114 p.3-��`�_fTo-�••g�•oo op 1A airy t„pem I�I er m d G t0 q pI F1 aM A n mm1 I� r_1 NYN b'. O INOI r'MprpNLX Y. 7 v p 7 C 21 r NAtalNMll ' S'I to 00 7y 0 T . II oew y A � •° � Qa0U0 I a�6d Q 0 N cao®oN• [f ..}v�7{ �� I I I YID WA F.• r ry 0 �� ONOAO 11 I p 3 ffl1 J m ;K O N y O O 9 Cl)•O �CO+.i o1 �C}F 4�pMCrp 1� G Q �� '� 0 l oWOt4P -"V a X17 a X �or4g I�• otwvabfl �w LO 9 9 hl M Nr 9 T T LA T L) M W Ln Im LD CU Q Job Name: _Truss ED: Al Qtv: 2 Orwa_ lite x-mr- RL=T SIZE 334.0 1 0- 2- 0 1204 4.00" 1_89.- 2 19-30- 0 1209 4.00" 1.89" 81te R620IREMUTS sho are based QILT an the twos nateclal at each bearing IC BOWCE AxL SHO, CSI 1-2 -2277 0.0e 0.51 0.59 2-3 -1941 0.34 0.37 0.71 3-4 -2277 0.09 0.51 0.59 BC FCRCc AXL Pao CBI 5-6 2076 0_51 0,;0 0.91 6-7 1912 0.47 0.18 0.65 7-9 1912 0.47 0.18 0.65 8-9 2076 0,5L 0.40 0.91 NES FORCE CSX NCB 6CAC2 CSI 2-6 295. 0_14 3-7 03 0.05 2-7 83 0_05 3-8 235 0.14 TC 2x4 SPY C2LOOF1,81 Plating spec • ANSI/TPI - 1995 2x4 SPP ft/02-CAN 2-3 TRIS DESIGN IB TnB COMPOSITE RESULT OP BC 2x4 SPF #1/42-CA18 MULTIPLE LOAD CASES. NRB 2x3 SPF Slim -CAN IRC/IBC trues plate values are based on Drainage most be provided to avoid ponding. testing and approval as required by FRC 1703 nip -Drop : 0-1-9 and ANSI/TPI and are reported in available This truss is designed using the doeunents such as ICBO #1607. ASC97-98 Wind Specification Bldg Enclosed = Yee, Importance Factor o 1.00 Truss Location = Not End Zone Hurricane/Ocean Lane - No,Exp Category m C Bldg Length - 40.00 ft, Sin width o 26.00 ft dean roof height - 9.49 ft, mph = 90 TPI Standard Occupancy, Dead Load = 10.2 pof Designed as Main Wind Force Resisting System and Components and Cladding Tributary Area a 60 sgft This design based on chord bracing applied per the following schedule: max 0.c. from to £C 36.0011 7-11- 4 12- 0-12 UPLIFT REACTIC04(S) Support Main B lib NON --Wind 2 -168 lb 7.114 4-1-8 7-11.4 7-11.4 12-0.12 20-0.0 7.11.4 I 4.1.8 I 7-11-4 1 2 g 4 4.06 5 X10 2 211 4.4 4-4 3.3.7 SFIIP S-0.3 t5 �-s..1s1 2.4 3-0 2.4 20-0.0 D-0 3 B 7 8 9 54-14 4-7-2 4-7-2 i 5,4.14 i 5.4-14 10.0-0 14.7.2 20.0-0 All plates are 20 gauge Truswal Connectors unless preceded by WWI for HS 20 gauge or "1111" for 18 gauge, posilloned per .taint Detail Reports available from Tnsswal Software, unless noled. ME DEFLECTION (open) c 1./999 MEM 7-6 QIVE) LC 1 L= -O.IL" D= -0.06" T= -0_ d'oint Locations =-- 1 0- 0- 0 6 5- 4-14 2 7-11- 4 7 10- 0- 0 3 12- 0-12 B Id- 7- 2 6 20- 0- 0 9 20- 0- 0 5 0- 0- 0 812112006 Scale: 3118' =1• nEnineered Building Components - 146 Washinglon Ave, S. ff /L1'(1Y11V V Read ail notes on this sheet and give a copy of it to the Freceing Contractor. 7Zrsdesi-m is form,indiidudbdidingrgmpanawnotarmMslem.llbrsWenbmdanspaaficalicnspr*;Mcdbcthecorcyloemnenuaclurer9and done inusetdaoceubhtbeeuacm ertiamsofTPiand AFFAd*tgnslxairrds. Nares,»ndtiliyisassumed fir disnos ionalaxsracy.Ilimersions we tobeterifedby11WComponent morafatturerardbrbudding designer priortof flealeon. The building designermastamonsiodukshe loXU p_r_ wilizedor 06dadi`eeloratcoedthe loading imposed byLhrloalbuiWingcode and %beputuuhrzpplirffidon. rhe designaaumesR,atthe top chani is lateralyfiretalbgtbenuforfloor sheilh�gandtbebwtamckmrdala:o�llybranadbyarigid�ealhrngmRerialdiTcalymuched,unlcssothermist nosed. bmcingslrOvnisrarbrosalsupp*atfcacpancrdsnxmbenonly torodreeboMingleugt4 TbhCompomcroshall not bepluslinany etrviranmentling uAcum ftnwidw000ntentohhewood toeueedt9%own•'erCause, canneworills[teorresion.Fal:ricue,handle, ijoAlSCLIY6 arc) brace this mus in ecoordanor. with dec fell owing standards Joint and LalLing Derail ROP ots' available as output trern TnsaaI software, :4NSKRIL','WTCAI'. Wood TtussCcueer ntilotAsiea$tarderdDesignResponsibilflies,'BiIiLDWOC*_VFONE!,7SAFETYDIFORMArION'- (UCSi1.03) and TOSSqh6ARYSBEETSbyW-MAand TP[ The Truss Pluto Instiluce(fP)itlocamiatJ33DOnarioDrive,MdsnHupklns,MN643 . aormwnd PpwSsaalte(AFFA}islocaledatIILLk9lhSlrcel,NW. Sic 900.Washingent,DC236 E°g• dab •E�, Chk: D99ar WORK ORS R# DB18Q11 7C Live 3$.00 of P TC Dead 7.00(18( 0.00 PSI ac Dead 1Di30psf TOTAL 5200 psi Apprax.tWG?erPly: BD lbs DurFacs "As Pe1,15 RepMbrBud 1.15 O.C.SpaCiR 9 2 0-0 Design Spec IRC4 Satin T6.5.S1- 0 W1 In 9 UN T in 3) D L) M Lli U) 9 Job Name: Truss !D: A2 -GT Qty: 2 ERG x -LOC EGA= 3228 BLQ'e TC 2X4 SFr C2loan.e6 1 0- 2- O plating2i spec ANSZ/TPI - 1995 2 19-30- O L 1913 4.00°913 4.00- 2.43^ 2X4 SPF 61/82 -CAN 2-4 THIS UggliLS THE CODOWITS RESULT Or 2.43, BC 2X9 SPF C2101IM SE Bit6-420IR3W-M shorn ane based ONLY MDLTZPLE LORD CASES. on the trues material at each bearing mS26H 2x3 SPP STUD -CAM ZRC/IBC truss plate values are based on Drainage uBt be provided to avoid pending. testing and approval as required by IHC 1703 71C EMACEn7o atm X51 Permanent bracing is required 4by others) to and ANSEAM7 and arca reported in available Prevent rotation/toppling. See HCS1 1-03 doeaments such ae IC80 81607. 1-2 -4315 0.20 0.39 8.58 and ANSI/TPI L. 2-3 -4008 0.37 0.39 0.76 3-4 -4908 0.37 0-39 0.76 4-5 -4316 0.20 0.39 O.S9 PC rMr. AHI. Hh9 car 6-7 4025 0.42 0.15 0.57 7-0 4035 0.42 0.19 0.62 8-9 4034 0.42 0.19 0.62 9-10 4025 0.42 D.L5 0,57 WE, TUMM Cal l® PORCH CSI 2-7 327 0.20 4-8 653 0.51 2-8 853 0.51 4-9 327 0.20 3-8 -349 0.11 6-41.4 4.0.12 4.0.12 5-,1.4 5-11.4 10.0.0 14.0.12 20.0.0 5-11-4 8-1-6 5.11 4 1 5-114 2 3 5 4 CM 29611 2165 X00 UPLIFT REACTIONIs) Supl:sirt Mai21Win 2tcn-Hind Chit: 2 -210 ib T"s trues is designeck using the TC Live ASC87-98 Mind Speeification Approx. Wt. Per Ply: 81 lbs 21dg Enc30aed = Yes, Importance Factor - 1.00 7.00 psi Truss Location = Not End Zone BC Live Harr-tcane/Ocean Line = No , Earp Catego = C Bldg Length - 40.00 Pt, HlWidth = 26.00 £t dg Mean roof height = 9.15 ft, mph o 90 BC Dead TPI Standard 0oarpancy, Dead Load = 10.2 pe€ O.C.Spacing 2-0.0 Designed as Main Wind Force Resisting System and Compensate and Cladding TOTAL Tributary Area a 67 eq€t Sevin Te,6,31 - 0 CASE NI DESIGN LOADS ---------------- Dir L.PIf L. Loc R.plf R.Loc LL/TL 7C vert 104.00 - 1- 0- 0 104.00 0- 0- 0 0.67 TC Vert 84.00 0- 0- 0 84.00 5-11- S 0.83 TC Vert 1(11.28 5-11- 4 101.28 14- 0-12 0.83 TC Vert 84.00 14- 0-12 84.00 20- 0- 0 0.83 TC Vert 104.00 20- D- 0 104.00 21- 0- 0 0.67 HC Vert 38.23 D- D- D 38.23 5-11- S 0.00 HC Vert 97.51 5-11- 4 97.51 14- 0-12 0.51 BC Vert 38.23 14- D-12 38.23 20- 0- D 0.00 .Type.., lbs X.Loc LL/TL TC Vert 60.0 - 1- 0- 0 1.00 TC Vert 160.1 5-L1- 4 1.00 TC Vert 36.0 5-L1- 4 0.00 TC Vert 180.1 14- 0-12 1.00 TC Vert 35.0 14- 0-12 0.00 TC Vert 60.0 21- 0- 0 1.00 T 5$ 2-4 5.6 4-0 T 2a T-0-3 15 4-8 a y03./6 I -7 2.4 3-6 2.4 1 20-0-0 iii 8 � 8 9 10 6.043-11-3 3.11.6 6-0-8 6-0-8 10.0-0 13.11-8 20.0.0 All plates are 20 gauge Truswal Connectors unless preceded by "MX' far HS 20 gauge er `H" for 46 gauge positioned perJoFnl Detail Repnds available from Tmswai software, unless noted, a ffAIUVL1YV Rwd all notes on thissheel and gnr a copy oifit to [lie Erecting CenIM016r, Engineered 7hisdesignisforanindividualbuiadingcompmrmtnoluusss}iterrL 3thashoambasedonsp4a6cnionsprovidedhylo,ownpmmaLinatanfsc9urer n ane done in xoord2twe with lbe wrram eenioni ofM and APPA drsign slandards. No r�p0nsibibn iiaasvvaed. inr diimdmi0sal aoaaacy. Dimensions BuiIQFng Mclsbcvenfiadbylheomepooma=Sjjfsturcran&0rbuitdireekdowprior iolabdraeon.Thcbuildngdsignramuuuserwolhartiseaoads 110imllonlhisdaWgnmedore-reedikeloading impMedbythe tMIbuildingepdeand sheparliedarapplkmian 7hedesign msunslhallhetop chcffi Components is erillybcs-Ad bylhemoforDoor shmillitgand Mahatwmebmdiilaleralhbmwd yarigid zMaihiagmaierWdimly uradred,aNessoftm ise noted. wingslry-m isBorb0e¢I yd'centpao,-n[smambosenh•rorcduxbucklingIerrglh.71dieaanpnnemshallnot UPIKedinany at',*MUM11nalwill ceuielhermistsmco0ntentefihcwnodae¢ntdl9fieanftrquscuoanworpliteooneien gabricamliandleinsiali and br -e chis ova in amordanre with the follindre siandards-loin; andCuaing Defad Repays' ovailalsle as onpm Ihoan Tnswal sollwara. WNW" V- Wood Tmss Comsii af_4mcrka SIEmdsd Design Re Wansttaflim%UILDING COMPON ah7• SAFETY' IWF0P-MATIW4'- 148 Wasilinglon Ave. S. (SCSI 1-0) mil M CS1 sl:_WMARY SHEETS' bg WTCA and TPL T& 7nrts Plaie EnaRate (TPi) is loosed In 5113 DOrrif a, Drive, Madison, Hopkins,MNISM3 (852)rA-49D2116'iarantin537L97he.4niericanForasiendPaperAssoaalimr(.4FPA)is5arateditE]11LS[bSt¢[,TW,Sn6004Vashiyglon,DC20036. MAX DEFLSCTIOM {span) : L/825 MSM 7-8 (LIVE) LC 1 I= -0.29° D- -D.14- T= -0., = Joint Locations --= ®1� 0- 0 0 6 0- 0- O 2 5-L1- 4 7 6- 0- 8 3 10- G- 0 8 Lo- 0- 0 4 14- 0-12 9 13-L1- 6 5 2D- 0- 0 10 20- 0- 0 8/21/2006 Scale, 3146" a 1' Eng. Job: ,EJ. WORK ORDER# Chit: Dsgnr: DB18011 TC Live 35.00 psi Approx. Wt. Per Ply: 81 lbs TC Dead 7.00 psi DDrFacs L=1A5 P-1.16 BC Live 0.00 pet Rep alba Bnd 100 BC Dead 10,00 psf O.C.Spacing 2-0.0 Design Spee IRC TOTAL 52.00 psf Sevin Te,6,31 - 0 a M Lh M M N In Ol O U P4 W Ol LQ N Job Name: - Truss ID: J1 Qty: 10 Drwa: aBG x-rrx MEACr 816t 1000-0 1 O- 2- 0 473 4.00" 1.501- .50"2 25- 9-C 1D0 4.00" 1.30" 3 5- 9- 4 209 4.00" 1.50^ BRo RCWJIPMMNrs shown are basad MY an the truas anterial at each bearing 7L• PORCe Ntl EM COX 1-2 -420 0.90 0.15 0.15 2-3 -43 0.00 0.15 0.15 3-0 -4 0.00 11.00 O." BC MP=O Axi Yno COI 4-5 303 0.09 0.13 0.23 5-0 0 0.00 0.00 G.00 NEB Form C91 RSB XoRC6 Cor 2-5 -411 0.15 TC 2x4 SFF kl/112-CAM Bc 2x4 SFF 41/82 -CAF MES 2x3 SFF STUD -CAN Mark all interior bearing location. Iastall interior suplaortiel before erection_ Shiva beariags (if needed) for reg, support. Plating speo : ANSI/M - 1995 TRIS DEBIGN Is MM CO MSITB RESULT OF MULTME LOAM CASES. LRC/211C truss plate valves are based on testing and approval as regn1red by TBC 1703 and ANSI/TBI and are reported in available documents such as ICBG #1607. 34-9 344 4�- 2.6-12� 5.11.4 UPLIFT REACTIONS) : support C&C b Non wind 2 -64 lb 3 -50 ib Thia truss is designed using the A9C67-9B Find Specification Bldg Enclosed - Yes, Importance Factor - L.00 Trues Location = Not End Sane Rarricans/Crean Line - No , Exp Category c C Bldg Length = 40.00 ft, Bldg Width = 26 -DG ft Mean roof height = 9.00 ft, uph = 90 TPI Standard Occupancy, Dead Load = L0.2 psE Designed as Main Find Force Eesistiag System and Coa ponsants and Cladding Tributary Area - 32 sgft 2-7-7 SHP MAX DBFLBCTI]IM (span) r L/999 MM 4-5 (LnM) LC 1 L= w_01" D= -0.03" T= -D.' =1 Joint Lnoations �__ ,Joint 0 4 0- 0- D 2 3- 4- a 5 5-11- 4 3 5-11- 4 5-114 4 g 5-11.4 5.11.4 8/21/2006 All plates are 20 gauge Truswal Conn=lors OVER 3 SUPPORTS unless preceded tiY'MX" for HS TO gauge or "H" for 1G ®Boge, positioned per JoIrA Detail Reports avalFsbleirom Truswa11 l software, unless noted. Seale: 19132" = r WARNING Read all notes o;•i 11jis skeet and gi we a copy of it to the Erecting Con rracror. Eng' Joh .15J. Engineered 7hstksytnfor animlMdualbuild9a2componentr inns system. ItInbeen based fmipeci6maonsProvided byThe ownpancra.Mmakettver done inamordencewitislhecuscrt Ctdc; WORK ORDS R# Building and versions arm wdAFPAdesignslardards. Nonspormbi5tyisamumedeordimeetieoalnxurwy. Dimensions membescnliedlrrw d§ecampancatm,tnuiaclarcrandabuildingdesignerr4iorm6hricrtiay. The! toildingdcsgnamust aw-cuinthee Onleads utiliaedasthisdesiperect Dsgni: DB18a11 amponents exceedOrLasdingimposedbythe local boitdingcoo wdthe psuimisapplissiort7hededguanunjorbulhetupclurd isbleallybramibythesnorernaorsheubingandthebottomchardislaterallybraxedbyarigidshw2ingmalmialdirectlys robed, ueltsselhernise uasnd.Brxtngihaxnisfar laterdsupper. ofoomponaftcrniWsanlyto TOUve MAD pat Approx. WLPer PAY: 23 lbs reduce bueklingteupb. This amponemalvrariot bepbeadimany 0Minr9MM;hastlleumethemoishavconminfebosoedtoescrod19%andrmmmetonncaorplaseamrodaiFstricate,handle, install TO Dead 7.00 pal' BC Live DarFs6SL=1.1513=1.15 Rep MbrBnd4.15 and trace this [rust inrcoordaacewith the following sandards3aintandOningEWAIttePods!Msila69eesomput6oninneatrattaase„ CADpsf 146 Washington Ave. S. Hopkins, M 55343 'ANSLMPr e.'w7CA r • Wrol TrsmQuncil erAfaMQ1 StEdud Desi3a COMPONMW W07Y WOMMA O . MM 1-44 rands-mCS) SUMMARY SR6B75'twXV MAMW 7M. The Tnui fame nstitae (Vi) i5 brAft! M 583 DUrafisoDrive. Madium, BC Dead 1p M pst OC.Spetislg 2-0-11 Design Spee IRC (952) 935.4902 Mriscensin 1719. The Amer an Forest andPsperAsmdaGtc5G1 PA) it located as 11 is 191h area¢ .VV,Sre.860,WsshinglOn,pC28036. TOTAL 52.00 p3( Sesigneqn Spec - 0 77�1 r4 X16 KBH CO_ NSULTINQ INC. PaulD. Schimnowski,.Owner..................-........................._............»_......-................,-.........-...........-......-.---_............._.................._............... August 22, 2006 Robert LeClaire 4624 3`d Street NE Fridley, MN 55421 RE: Segmental Retaining Wall Typical Sections 4624 3`d Street NE Fridley, Minnesota KBH No. 2006.092 Dear Mr. LeClaire: This letter is being sent to discuss our typical engineered section for the segmental retaining wall at the 4624 3"d Street NE project in Fridley, Minnesota. This design is based on written information provided by you during a site visit on August 22, 2006. No formal soil report was provided for this project. I understand that the proposed Allan Block Classic Retaining Wall System will be located along the north property line. The wall will vary in exposed height from 5.5' to 1' and will be about 100' long. Level slopes will be located at the top and bottom of the wall. A minimum embedment depth of 6" should be maintained for all wall sections. No other surcharge or groundwater loads have leen designed for the wail. Direct all surface drainage away from the wall. The attached typical section should be referenced for the appropriate wall section height. Special note should be made of the wall embedment depth and the geosynthetic fabric (geo-grid) length as measured from the front face of the wall. Refer to Allan Block Retaining Wall Systems Standard Specifications for installation information and details. The design of the wall system assumes the following: Soil conditions: Sandy Silt/Clay, friction angle = 32.0 degrees, unit weight of 120.0 Ib/ft3 Allowable soil bearing capacity = 1,500 psf No external surcharge loading behind the wall Level slope at top and bottom Minimum embedment depth = 6" Block Type: Allan Block Classic Geosynthetic Fabric Type: Fortrac 35/20-20 Direct all surface drainage away from the wall. The wall design was performed using the design guidelines presented in the second addition of the "Design Manual for Segmental Retaining Walls" KBH Consulting, Inc. 7226 391h Street North, Suite 100 Oakdale, MN 55128 (651) 779-7700 4624 3rd Street NE, Fridley, Minnesota August 22, 2006 Page 2 (DMSRV) published by NCMA in 1996. If soil conditions, proposed wall layouts, or other design parameters vary from that assumed, a revised analysis may be needed. Please call me if you have any questions or need more information. Thank you. Sincerely, y � _ Paul Schimnowski, PE MN #40126 DESIGN PARAMETERS AND PROVISIONS 1. REFER TO ALLAN BLOCK RETAINING WALL SYSTEMS STANDARD SPECIFICATIONS FOR SEGMENTAL RETAINING WALL UNITS. 2. SEE PRODUCT MANUFACTURER INSTALLATION RECOMMENDATIONS FOR CONSTRUCTION SEQUENCE AND INSTALLATION NOTES. 3. NO PRODUCT/MATERIAL SUBSTITUTIONS WILL BE ALLOWED WITHOUT PRIOR WRITTEN PERMISSION OF KBH CONSULTING, INC. 4. OWNER OR OWNER'S REPRESENTATIVE IS RESPONSIBLE FOR ENSURING THE CONDITIONS STATED HEREIN ARE ACCURATE PRIOR TO AND DURING CONSTRUCTION. NOTIFY KBH CONSULTING, INC. IN WRITING OF ANY DISCREPANCIES OR CHANGES TO THE CONDITIONS SHOWN ON THESE DOCUMENTS. 5. REFER TO WALL ELEVATION NOTES FOR WALL SURCHARGE LOADINGS AND SLOPES AT TOP AND BOTTOM OF WALL(S). REFER TO WALL CALCULATIONS FOR BEARING CAPACITY REQUIREMENTS. 6. FINAL SITE GRADES AND ROOF DRAINS SHALL DIRECT RUNOFF AWAY FROM ANY RETAINING WALLS. 7. KBH CONSULTING, INC. ASSUMES NO LIABILITY FOR INTERPRETATION OF SUBSURFACE CONDITIONS, SUITABILITY OF SOIL DESIGN PARAMETERS AND INTERPRETATIONS OF SUBSURFACE GROUNDWATER CONDITIONS. 8. THE OWNER OR OWNER'S REPRESENTATIVE IS RESPONSIBLE FOR CONTACTING THE WALL DESIGN ENGINEER TO SCHEDULE A SITE VISIT PRIOR TO THE START OF BLOCK PLACEMENT. 9. THE WALL DESIGN WAS PERFORMED USING DESIGN GUIDELINES PRESENTED IN THE SECOND EDITION OF THE "DESIGN MANUAL FOR SEGMENTAL RETAINING WALLS" (DMSRW). PUBLISHED BY NCMA IN 1996. 10. THE DESIGN OF THIS RETAINING WALL WAS BASED UPON INFORMATION NOTED ON THE KEY PLAN. 11. THE INFORMATION PROVIDED WITHIN THESE DOCUMENTS IS FOR THE STRUCTURAL DESIGN OF THE PROPOSED WALL(S) ONLY. THE REQUIREMENTS FOR AND/OR WORK RELATED TO HANDRAILS, GUARDRAILS, OR OTHER LIFE/SAFETY ISSUES ARE EXCLUDED FROM THESE DOCUMENTS AND ARE TO BE PROVIDED BY OTHERS. 12. RESPONSIBILITY FOR GLOBAL/SLOPE STABILITY RESTS WITH THE SITE CIVIL OR GEOTECHNICAL ENGINEER KBH Consulting, Inc. 7226 39th Strut North, Suite 100 Oakdale, MN 55128 (651)779-7700 SRWall (ver 3.22 April 2002) Page 6 �lln -- --- " 6.1 degrees 6.33 ft 6.0 ft � n Ll _o Fortrac 35/20-20 Fortrac 35/20-20 /I 0.5 ft Fortrac 35/20-20 -0.5 ft 3.6 ft Proiect Identification: Proj ect `oe���il►���� t//// Name: 4624 3rd Street NE, Fridley, IST ®esu` ..®�• o Section: 5.5' exposed height section Data Sheet: 2006.092 Owner: Robert LeClaire ENGINEER a Client: Robert LeClai.re .� esl ,• 40126 v Prepared by: Paul D. Schimnovski, PE iso ,q;I I Date: August 22 2006 /n WO�� Time: 02:58:53 PM Data file: c:\documents and settings\pawl schimnovski\my documents\kbh files\srwall files\2006.092-6ft City of Fridley Building Inspections Department 6431 University Avenue NE, Fridley, MN 55432 763-572-3604 FAX: 763-502-4977 MECHANICAL PermitNo.' i- 3a' ,,ions RESIDENTIAL APPLICATION Received By:l :w ,-572-3604 CITY OF FRIDLEY n 163-502-4977 FAX DATE - U- YOUR'ADDRESS SITE ADDRESS (C'I , ,( !2 i THIS APPLICANT IS: ❑ OWNER )<ONTRACTOR PROPERTY NAME: ADDRESS: 6_% � �� CITY STATE ZIP OWNER/ TENANT PHONE: CONTRACTOR COMPANY NAME: SUBMIT A COPY OF CONTACT PERSON: YOUR STATE STATE LICENSE # XP DATE `�� LICENSE WITH ADDRESS: CI�T`Y���q �Y STATEIfDIIP APPLICATION PHONE _ FAX -1LQ_J-- lF +4 - 0 PERMIT TYPE SINGLE FAMILY ❑ TWO FAMILY ❑ TOWNHOUSE TYPE OF WORK- ❑ NEW PLACEMENT ❑ ALTERATION/REMODEL DETAILED DESCRIPTION OF WORK PER MS 16B.665 the permit fee is a minimum of $15.00 or 5% of the total cost up to $500.00, whichever is greater, for the improvement, installation or replacement of a residential fixture, excluding the fixtures. (This should reflect only the cost of labor ) Labor cost under $600 = $15.00. Labor cost between $300 to $500 = cost of labor X.05 = FOR PROJECTS WHERE LABOR EXCEEDS $500, FEES ARE BASED ON $10.00 PER FIXTURE, EXCEPT WHERE NOTED. FIXTURES: (INDICATE TOTAL NUMBER OF EACH BELOW) Equipment Installed MFG:?yun �1 (� tvo MODEL: C �' �4' 1qS6IZE/BTU MFG: MODEL: SIZE/BTU MFG: MODEL: SIZEBTU $25.00 (GAS) $15.00 _GAS RANGE/OVEN $10.00 _A/C _FIREPLACE TO AIR EXCHANGEER $15 FIREPLACE (WOOD) $35.00 _NEW GAS GRILL $10.00 _AIR _BOILER $35.00 _-FURNACE $35.00 _GAS UNIT HTR $10.00 LINER $10.00 GAS DRYER $10.00 _POOL HEATER $35.00 _CHIMNEY DUCT WORK $10.00 GAS PIPING $10.00 _VENTILATOR $15.00 P FEE 5. .,. T F1=1 FOR PROD f O'4f1R rr ., Permit Fee $Number ,....... . of fixtures @ $10.00 x $10.00 = $ Surcharge Number of fixtures @ $15.00 x $15.00 = $ TOTAL DUE $ Number of fixtures @ $25.00 x $25.00 = $ Number of fixtures @ $35.00 x $35.00 = $ State Surcharge = $ .50 Total = $ D -V THIS IS AN APPLICATION FOR A PERMIT -NOT VALID UNTIL PROCESSED I hereby apply for a building permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Fridley and with the Minnesota Construction Codes; that I understand this is not a permit but only an application for a permit and work is not to start without a permit; that the work will be in accordance with the approved plan in the case of all WMA whic es review and approval of plans. �y1� l Q PRINT NAME V I� 1-C_ bu�DATE SIGNATURE OF APPLIC S Cil°BtlLT2N43,L'_.WWII City of Fridley Building Inspections Department 6431 University Avenue NE, Fridley, MN 55432 763-572-3604 FAX: 763-502-4977