Loading...
PRE 2010 DOCS*City of Fridley, Minn. 0 BUILDING PERMIT N° 4330 Date:. - NOVINM —'2-L.�...1959 Owner: .................. ......_............. -...................... ......... _........... -.-........ ..................... Builder ................. P=. .. B Address ....._ ...................... ............ .......... .._...._..._._._.__............_.._............... Address ..----.._.....V_1.9 . ..... A9E21T1S.._-%f1'I'' l....._-- Minneap®lie, Minnesota LOCATION OF BUILDING No. ...... giM -_ --------- Street .......................... 7..tA....bfteet...N:..................................... Part of Lot ..... -........... ........... .... ...................... _.......... ..... -- Lot.........27 ..................... Block . ............ ........ 1......................... Addition or Sub -Division ... -®.._90414W40....4�dl� t_Lon CornerLot .................................... Inside Lot ............. g.................... Setback ................ 33.._t................. Sideyard.................................................. -....... ...... ........... SewerElevation .................................................. -................................ ..................... Foundation Elevation ............................... -.--............. -............................ .... ---- ... __ DESCRIPTION OF BUILDING To be Used as: .-------_--_ Front w t Depth W49!, Height .... _�9 ...... Sq. Ft. 1109 .. 'x- -1'97' .... --- t . ... ........................................................... Front ........................ Depth .__.............._.. Height ... - _.... _.... Sq. Ft......................... Cu. Ft. ..... _................. Type of Construction ......Vie .................._........ Est. Cost... 439.0°!1.. ................... To be Completed..................................................... In consideration of the issuance to me of a permit to construct the building described above, I agree to do the proposed work in accordance with the description above set forth and in compliance with all provisions of ordinances of the city of Fridley. v I In consideration of the payment of a fee of $.......�.�.1l........, permit is hereby granted to .............. ....._............._. .................... _.. .....___....._...._.........._...................................... to construct the building or addition as described above. This permit is granted upon the express condition that the person to whom it is granted and his agents, employees and workmen, in all work done in, around and upon said building, or any part thereof, shall conform in all respects to the ordinances of Fridley, Minnesota regarding location, construction, alteration, maintenance, repair and moving of buildings within the city limits and this permit may be revoked at any time upon violation of any of the provisions of said ordinances. Building Inspector NOTICE: This permit does not cover the construction, installation for wiring, plumbing, gas heating, sewer or water. Be sure to see the Building Inspector for separate permits for these items. 4 City of Fridley, Minn. BUILDING PERMIT Date:...__.._...•"`'°' .... q_,__L.�? _a...._;_.__.— f Owner: ._..� .. uilder Address _.._.._.._.__._ _ _.. _ Address N° �,��� LO OF BUILDING No... Streett+•_. a.._:a�................... ....... Part of __._ .._.��_�..._.... _....� Lot s .. ...._........ Block .. -- /" -•------------ - ................ Addition or Sub- __..4.0 Corner Lot .......................... _........ Inside Lot . .... ......... Setback .f...... ideyard ....._.. ' _.....__..._.. -------..... ................ .. Sewer Elevation ..................... ........._..._._.._..._................................ ......._._ Fo ation Elevation .:.................................. DESCRIPTION OF BUILDING To be Used as: _ L..... Front ...: Depth � . r e..._.. Height .... f.._ 14. Ft. Cu. Ft.JF _.............._...... _......._.............. Fro _.._ - Depth ...................._. ignnht ..... . -.-. Sq. F't............... .... ... Cu. Ft- ..... _................. Type of Construction _'...-4....... Est. Cost::::..J-.-.o�-.-_ To be Completed .................................................. CAUTION LAT - THIS PERMIT DGES_ NOT AUT ORIZE VI COVENANTS AND ION OF ANY P;:t.,ATE LAND tt.ri:'G i�w�t'1arTIONS. In consideration of the issuance to me of a permit to construct the building described above, I agree to do the proposed work in accordance with the description above set forth and in compliance with all provisions of ordinances of the city of Fridley. In consideration of the payment of a fee of_....�"�r. $� ---, permit is hereby granted to. ........... _._._...-----•----------_....---•---.--_-. to construct the building or addition as described above. This permit is granted upon the express condition that the person to whom it is granted and his agents, employees and workmen, in all work done in, around and upon said building, or any part thereof, shall conform in all respects to the ordinances of Fridley, Minnesota regarding location, construction, alteration, maintenance, - TeWr and moving of buildings within the city limits and this permit may be revoked at any po violation f any of the provisions of said ordinances. 'AR f NOTICE: This permit does not cover the construction, installation for wiring, plumbing, gas heating, sewer or water. Be sure to see the Building Inspector for separate permits for these Mems. =f' APPLICATION FOR BUILDING PERMIT CITY OF FRIDLEY, K1NNESO7A Owners Name �"Builder Address G9 Address � LOCATION OF BUILDING No. ( �/ Street -7-1 a,) i) Part of Lo Lot ]Block--/ Addition or Sub.D Corner Lot Inside Lot Set Back Side -Yard SEWER ELEVATION FOUNDATION ELEVATION Applicant attach to this form Certificate of Survey of Lot and proposed building location. DESCRIPTION OF BUILDING To be used as: Front Depth Height ✓.,,.. Sq. Ft. L L Cu. Ft. G Cl ( Front Depth Height Sq. Ft. 0u. Ft• Type of Construction�Estimated Cos, To be The undersigned hereby makes application for a permit for the work herein specified$ agreeing to do all work in strict accordance with the City Ordinances and ruling of the Department of Buildings, and hereby declares that all the facts and representa- tions stated in this application are true and correct. / ' DATE `` CCS SIGNATURE c (�, ., , to Schedule of Fee costs can be found on the Reverse Side.) NLI% .w y Sim BIDCIL ADDBMS,-`,-4 VALUATIM ..... ..... . ...... .. .... .... ...... .. ........ ............... ............. .. ...... . ...... ............. ... . ... .............. ...... .................................... ............. ..................... ......................... Aw f's ....................................... ...•................0• ................ ....................................... .0 .............. I ......................................... a MINIMUM FEE FOR ANY HEATING PERMIT IS $15.00, PLUS $.50 STATE SURCHARGE Attach stack verification fora with. replacement furnace permits *Air Conditioners can not be placed in side yard without written permission from adjoining neighbor. BURNER - Trade Name Size No. Capacity Sq. Ft. EDR BTU HP Company , Dependable Heating and A/C Signed Bye1-1 ==� Tel. No. 757-5040 CITY OF FRIDLEY Effective Date May 1, 1988 APPLICATION FOR OWER PLANTS AND HEATING, COOLING, VENTILATION, REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES RATE SCHEDULE -RESIDENTIAL RATE TOTAL, Job Address 5431 7th St. NE Furnace Shell and Duct Work, Burner (Also replacement furnace) $ 20.00 $ Department of Buildings, 6431 University Ave. N.E., Fridley, MN 55432 Gas Piping $ '10.00 $ City of Fridley Tel. #571-3450. (piping needed with new furnace) Gas Range $ 10.00 $ The undersigned hereby makes application for a permit for the work herein Gas Dryer $ 10.00 $ specified agreeing to do all work in strict accordance with the City Codes ' and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct. * Air Conditioning (all sizes) $ 10.00 $ 10.00 Fridley, July 14 89 Minn. 19 All Others/Repairs and Alterations 1% OWNER Daniel Bursey of Value of Appliance or Work $ KIND OF BUILDING Frame COMMERCIAL/INDUSTRIAL Residential USED AS 1% Of Value of Appliance or Work $ TO BE COMPLETED ABOUT State Surcharge $ .50 ESTIMATED COST $1500.00 TOTAL F=OLD $ - NEW BUILDING PERMIT PLO. PERMIT NO. �avi(p Reinspection Fee ($15.00) $ DESCRIPTION OF FURNACE/BURNER Rough Insp. **INSTALLING ONE (1) CARRIER Date 8TG024 2 TON AIR COND. HEATING or POWER PLANTS, Steam, Hot Water, Warm Air- No. Final IIISp. �sa�� $� Trade Name Size No. Date Approval for Permit 14,-- Capacity Sq. Ft. EDR BTU HP Total Connected Load Kind of Fuel MINIMUM FEE FOR ANY HEATING PERMIT IS $15.00, PLUS $.50 STATE SURCHARGE Attach stack verification fora with. replacement furnace permits *Air Conditioners can not be placed in side yard without written permission from adjoining neighbor. BURNER - Trade Name Size No. Capacity Sq. Ft. EDR BTU HP Company , Dependable Heating and A/C Signed Bye1-1 ==� Tel. No. 757-5040 sue"ECTMIT NO. City of Fridley AT THE TOP OF THE TWINS BUILDING PERMIT (�_ 30850 r ` COMMUNITY DEVELOPMENT DIV. L __ PROTECTIVE INSPECTION SEC, 1 CITY HALL FRIOLEV 55432 L 612-571-3450 RECEIPT NO. NUMBER 910-F15 REV DATE 4/24/00 PAGE OF APPROVED BY JOB ADDRESS 5431 7 Street NE 1 LEGAL DESCR. LOT NO. 27 BLOCK 1 TRACT OR ADDITION SEE ATTACHED 1 Lyndale Builders 4th Addition SHEET 2 PROPERTY OWNER MAIL ADORES$ ZIP PHONE Lionel Flood 5431 7 Street NE (763) 671-7396 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO 8 USE OF BUILDING Residential 7 CLASS OF WORK O NEW ❑ ADDITION O ALTERATION f7 REPAIR O MOVE O REMOVE 8 DESCRIBE WORK Reroof House & Garage (24 Sq) Tear -off 9 CHANGEOFUSEFROM TO STIPULATIONS Underlayment must comply with the State Building Code. SEPARATE PERMITS ARE REQUIRED FOR ELECTRtCAI, PLUMBING. HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 80 DAYS, OR IF CONSTRUCTION ZONING SO. FT CU FT. OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT VALUATION $2,098 SURTAX @ $1.05 DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- STRUCTION OR THE PERFORMANCE OF CONSTRUCTION PERMIT FEE $53.25 SAC CHARGE Fire SC $2.10 PLAN CHECK FEE TOT FEE SIGNATURE OF CONTRACORiZED AGENT IDAT i \ '116.40 ENMP VALID TNI$ I$ YO R ERMI / S.GNATURE OF OWNEA of OWNER GUILDERi ATEA RL -NSP FSA E NEW L ] Effective 1/1/2000 ADDN [ ] CITY OF FRIDLEY (763) 572-3604 Blctq Insp ALTER [ ] SINGLE FAMILY AND DUPLEXES R-1 AND R-2 BUILDING PERMIT APPLICATION Construction Address: S W I `7 T-0 S? 'J Legal Description: (_o i 1_-) 1 Q2L& J' I 440A/-9 MygLjQ;--1, 4111 1 3A fA o,,) Owner Name & Address: L, am. -L— 7C-0 , 414 % ,AIK, Tel. # C7u3L) C71—?3.96 Contractor: _ ��� MN LICENSE # ^� Address: Tel. # LIVING AREA: GARAGE AREA: DECK AREA: OTHER: Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF IMPROVEMENT Length Width Height Sq. Ft. Length Width Height Sq. Ft Length Width Hgt/Ground Sq. Ft Construction Type: Estimated Cost: $ Driveway Curb Cut Width Needed: Ft. + 6 Ft = Ft x $ _ $ C;�69re DATE: Z 2 M% APPLICANT: Tel. # S "71-2 361 CITY USE ONLY - Call (763) 572-3604 for Permit Fees If mailing In application Permit Fee $ CID, c2i Fee Schedule on Reverse Side Fire Surcharge $ �. < .001 of Permit Valuation (1/10th%) State Surcharge $ $.50/$1,000 Valuation SAC Charge License Surcharge Driveway Escrow Erosion Control $1100 per SAC Unit $5.00 (State Licensed Residential Contractors) $ Alt. "A" or Alt. "B" Above Park Fee $ $450.00 Conservation Plan Review Fee Determined by Engineering Sewer Main Charge $ Agreement Necessary [ ] Not Necessary [ ] TOTAL STIPULATIONS: $ Cq1-�/v SUBJECT P City of Fridley 33694 AT THE TOP OF THE TWINS r BUILDING PERMIT COMMUNITY DEVELOPMENT DIV. PROTECTIVE INSPECTION SEC. k4 3yo? 1 NUMBER REV DATE PAGE Of APPROVED BY CITY HALL FRIDLEY 5532 �j 763-571-3450 910-F15 7/11/03 JOB ADDRESS 5431 7 Street NE 1 LEGAL LOT NO. BLOCK TRACTOR ADDITION SEE ATTACHED DESCR. 27 1 Lyndale Builders 4th Addition SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Lionel Flood 5431 7 Street NE 763-571-7396 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO Same d ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO 6 USE OF BUILDING Residential 7 CLASS OF WORK ❑ NEW QX ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE O REMOVE X B DESCRIBE WORK Install a 24' Round, In -ground Swimming Pool and a 40' x 16' Deck 9 CHANGEOFUSEFROM TO STIPULATIONS See notations on plan. See requirements on letter dated July 11, 2003. WA RK"I G SEPARATE PERMITS REQUIRED FOR: Before digging call for WIRING HEATING all utility locations PLUMBING .AND SIGNS 454.0002 REQUIRED BY LAW SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCYLOAD VENTILATING OR AIR CONDITIONING THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT CU FT AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT i HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $6,000 $3.00 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMITFEE SACCHARGE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON- $125.25 Fire SC $6.00 STRUCTION OR THE PERFORMANCE OF CONSTRUCTION PLAN CHECK FEE TOTALFEE $134.25 J16CNAT UpEOFCON'AA,CTTOOROPAUTHORIZE GENT MATES WHEN PROPERLY VALIDATED THIS IS YO R PE IT EILOG iNSP GATE SSG ATURE OF OWNER.iF OWNER BU4DERI IDATE, NEW [ ] ADDN [ ] ALTER [ ] Construction Address: CITY OF FRIDLEY Effective 1/1/2003 6431 University Ave NE, Fridley, MN 55432 (763) 572-3604 Bldg Insp SINGLE FAMILY AND DUPLEXES R-1 AND R-2 (763) 5714287 Fax BUILDING PERMIT APPLICATION Legal Description: L 0 T e- 1 P l Cc -t- I I - v 4 o "« o u.< <ae a I (T ( on Owner Name & Address: kO"eA -Ioc l Tel. # h /o3 571-73 Contractor: D w 6 P_ v/- MN LICENSE # Address: Tel. # Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. 2 DESCRIPTION OF IMPROVEMENT LIVING AREA: Length Width Height Sq. Ft. GARAGE AREA: Length Width Height 2W Sq. Ft. TOW PECK AREA: Length `�� Width «" Hgt/Ground 2-,14• Sq. Ft. OTHER: ?-y" rwwnd Nlow-- Construction Type:�i�eLk� 4 co��os► vra Est ed Cost: $ ��o,Gc� Driveway Curb Cut Width Needed: Ft. + 6 Ft = Ft x $ _ $ DATE: (P -k APPLICANT: Tel. # '76!> 5-21-235 Call (763) 572-3604 for Permit Fees if mailing in application. Fax to 763-571-1287 if using credit card and we will call you for card number. CITY USE ONLY - Permit Fee $ Fee Schedule on Reverse Side Fire Surcharge $ .001 of Permit Valuation (1/10th%) State Surcharge $ ? a O® $.50/$1,000 Valuation SAC Charge $ $1275 per SAC Unit License Surcharge $ $5.00 (State Licensed Residential Contractors) Curb Cut Escrow $ Alt. "A" or Alt. "B" Above Erosion Control $ $450.00 Conservation Plan Review Park Fee $ Fee Determined by Engineering Sewer Main Charge $ Agreement Necessary [ ] Not Necessary [ ] TOTAL $ 13465 6y! Gita% ; 1 CfI1fOF FRIDLEY FRIDLEY MUNICIPAL CENTER - 6431 UNIVERSITY AVE. N.E. FRIDLEY, MN 55432 - (763) 571-3450 - FAX (763) 571-1287 July 11, 2003 Lionel Flood 54317 Street NE Fridley, MN 55432 RE: Swimming Pool Construction at 54317 Street NE, Fridley Dear Mr. Flood: This letter is to make clear this department's requirements for the swimming pool construction at the above address. 1. As indicated, one (1) skimmer approved by the National Sanitation Foundation will be provided. 2. As indicated, one (1) inlet of approved design for fresh and/or repurified water will be provided. 3. The filter and pump shall be approved by the N.S.F. and be of sufficient capacity to provide a minimum turnover of at least two (2) times in 24 hours. This department recommends a turnover rate of 6 - 8 hours. 4. A deck of at least three (3) feet wide, measured from the pool waters edge, shall be provided which extends completely around all private residential pools. Above ground private residential pools may be provided with decking of a minimum size of 4 feet by 4 feet at pool entry points and provided that such decking has the approval of the City. 5. Fencing or other effective means including but not limited to walls or buildings, acceptable to the City. Fencing shall meet the following criteria: a. The fencing shall prevent the entrance of children and be without hand or footholds that would enable a person to climb over it. b. The fencing shall be at least 6 feet high and entrances shall be equipped with self-closing and self -latching gates capable of being locked. c. Self-closing and self -latching devices shall be placed at the top of the gate or otherwise inaccessible to small children. d. The opening between the bottom of the fence and the ground or other surface shall be not more than four inches. July 11, 2003 Lionel Flood Re: Swimming Pool Construction Page 2 6. An automatic chlorinator should be provided with a suitable test kit. 7. All electrical and plumbing installations shall be inspected and approved by the City Inspection Department. B. All overhead electrical lines must be a minimum of 10 feet horizontally from the pool surface and 18 feet straight line distance from the waters edge. An alternative is to bury said lines. 9. The pool fill spout must be protected by a vacuum breaker or air -gapped. 10. Suitable safety equipment to include but not limited to a ring buoy and rope that is 1 1/2 times the pool diameter, and shepherds crook pole must be provided and maintained with the pool at all times. Furthermore, these and any other requirements must meet the provisions of the Fridley City Code, Section 115, Swimming pools. The building permit is approved contingent on final inspections and approval by the City. If any questions or problems arise from this letter, please contact me at 572-3603. Sincerely, DJ/mh i 7I GIM& LSON J. E. HILL,' Ci 'RECORDS OF 'HARVEY. A CARTVIfRIGHT � J. E HILL,: CrvIL° BNOINBSR ANOKArCOUNTY' SURVEYS [[rwDupNED .ISN NgNNZPIN:COUITY SURVEYS LAND 'SURVEYORS C. F. SANDHOFIF sMINNKAP01.14 '.OURVEYB CIVIL ENGINEER 6410 PALM "STREET N. W. R6a18TUR[_ D UNDER LAWS OF STATE OF MINNESOTA ZBTABLISNtD • ISW" 6UNt[T 4-11658 LICENSED BY ORDINANCE OF_.CITY OF MINNEAPOLIS JAMES NELSON OWNER FEDERAL 8-8721 4 326 PLYMOUTH BUILDING SURVEYOR • �. ` ' - - [BTA• tMtO, -ltfi INDUSTRIAL`= IuolclwL HENNEPIN AT SIXTH. • MINNEAPOLIS 3. MINNESOTA METROPOLITAN LAND BUSINESS —'TOPOGRAPHICAL CITY LOTS'--PLATTING l�urbcpor'»c �crhitcatc ',SullvcroR6, iSTAtLI[NW.IYS/ :Lyndale.Builders Invoic0 20906 i q A•.; ` .� l x O � l _ s `lf Z, 80' S �npe o Thereby certify that this is a true and correct representation of a survey of the boundaries of: Lot 27, Block 1, Lyndale Builders 4th addition As surveyed by.me during the Month of September, 1959. ' 1 810NtD f C 1014T AND OL80N .�•1•, it s�. • ' � , fA �•:• er ii:�`.'q• •^j�!.•!t:�:. .ei4�%rr� '�w !• • .. ...,... . . .+,a'�•.��:,... .. r � .. «. _1t ._ .. .... N •� �� Y L 3 • -:%fir•. ��.' '�,.,. ,�: :.s. lbs t•M�uw? }t`:i!.k�C'b�. :1'ttri t�. •'' t •-wr. ':+; :�'Ji� •.�'�, :: . WQ�'WA L. q.. 00, �.I. 421 Ov ';''+'<' hi?s'` ,: is l '•.'. i:.,:.:. :::• .�,Y:• ? .;.•�?', ,e,i.':r.. � „, i;:c..::s e''t:y,,e�,...'..i.'• ::p'' ,:wr � ... t < :..r..,g7:. `..:: ..... , 1, r 'r ;, 'fig: ;�.: `.:• i •: r.... ': T., ,. �. r�' �g•'iT%' �Jr'U � .,,�,i: ,q � � „.a , t+ .`wt.�t.{: �;w:L,, .�'.::,.•:.'.... . .. ....-,.....- i� -,bb! i t to • .' art,..:: �fF� ... _ .,tom ;�.. �«7,J•Z:..: .. � .t • .... ,�, .. .. .. � � �� . : ! it .. .•fir••. � 4 Jul 0903 03:31p Watsons 952 937 6866 P.1 .. ... ... ... ...... .. ...... ... ... ... ...... ... ... ... ... ... ... ...... ... WATSON'S OF MINNEAPOLIS 15450 CEDAR AVENUE APPLE VALLEY. MN 55124 PHONE: 952-997-6.000 PAX. 952-997-6866 FACSIMILE TRASMITTAL SHEET FAX: 5 -7 1 PHONE FROM: 7 'DATE: TOTAL NO. Or PAGES INCLUDING COVER: 77cc.. C . ta 0 URGENT FOR REVIEW 0 PLBASS COMMENT 13 PLEASE REPLY❑ PLEASE RECYCLE ? K } 1 kN,� ' > III �— .,I e,�r DO NOT JUMP OR ONE. 3����2 �.` n. INJ URY MAY RESULT, ,Urers of Quality or b SHAILOIY WATER! Jul ....09... 03....03. 31 p...................Watsons....................................., .. 952 997 6866 p....3............. ..................................................................................................................... 4 GENERAL INFORMATION Before attempting to set up the pool, read the entire Instructions. There aro certain areas In the Instructions that aro exo^emelyr important to follow exactly as Written and/or pictured. Any deviation from these krstructkrn voids warranty of the pod and could cause bodily herrn or damage to your property. Open the cartons and remove all parts except steel well and pner. Before pod assembly, you must identify, count and check all parts for assembly by parts Iist. Familiarize yourself with all of the parts. Refer to the parts list. CAUTION: Do not start the Installation of your pod unless you have an entire day to finish the work. Do not try to set up your pod on a wh* day. The wap will be difficult or even Impossible to handle. An average pod needs 2 or 3 people for Installation. The following tools and materials are heeded, SuxewdrIW Earth Roger Shovel Tamping Tool Strktg Marldng Pencil Pegs and Stakes Hammer G Naps Masking Tape Carpenter's Level Sand Rake Measuring Tape M4- Board Chap( or Fkwr Patio Block Plastic Tape 1) SELECTION OF POOL SITE Before starting the Installation, the following points are Important; a) The site must be large enough to accommodate the pod with Plenty of area aroarvd It for pool accessades, chaps, tables etc. b) DetertNne where your filtration and skimmer will be located. It must be connected to a grounded 110 volt electrical oWet, with a G.F.I. (Ground Fault Interrupter) c) The pool mutat be In react of your water supply, Although the water should not be drained, but kept clean through filtration and chemicals, there should be drainage faclitles near in vase of need. d) Perimeter area of ground must be absolutely level and firm. All grass and sod Wider entire pod area must be dug out to avoid unpleasant odors from decomposition corder the pod due to iadr of ah. Remove sharp objects, stones, twigs, pebbles, root:, etc, They may damage the liner. If the ground has been treated with chenkab or weed taper allow two weeks before setting up the pool. Do not set up the pod on concrete, asphalt, tar paper, peatmoss, sand, gravel, or where nut grass has been planted. Poorly Prepared ground could allow, certain weeds or grass to grow through the liner, Uner is not warranted against this. if ground Is uneven In perimeter area, dig out the high spots. Do not build up the low side by padding it vith earth. The weight and movement of the water will peck down the Bp causing the pod to sink. Inside perimeter of pool the area Inside of the frame and wall) ton be leveled with 1' or 2' of sand raked and rolled smooth. FAIWRE TO OBSERVE ANY OF THE ABOVE INSTRUCTIONS WILL VOID WARRANTY. SIFTED EARTH OR SAND NEEDED PER EACH SIZE POOL AS FOU OW& 12' otameter Pod 18 cubic feet 15' Diameter Pod 29 cubic feet ' TO' Dianwter Pool 42 cubic fest 21' Diameter Pod 57 cube feet 24' Diameter Pod 74 cubic feet Zr Diameter Pod 94 cubic feat 30' Diameter Pod 116 cube feat 33' Diamner Poo( 140 cubic feet Jul 09 03 03:32p Watsons 952 997 6866 p.4 .. ... ... ... ... ... .............................................................................................................................,..... ... ... ...... ... ...... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ............................................ ............ ...... •L) GKUUNU PlAtNAKAIIUN The preparation of the ground Is the most ,I important step In the Instaliatlon of the pool. a) Mark off your pod area by drMM stakes. Have a helper hold a tape measure or a string and nark off the pod perimeter using flour or chalk. Remove sod Inside the pool area to a distance of 1 feat beyond dimensions shown In the plot layout around entire perimeter of pool. b) Remove all grass from wlthln the entire pool area. lt Is not enough to Just cut the grass. The sod must be removed D.,nl nir„ancinn R. WAIL I iRnOth POOL�SIZE ----- -- Diameter Wally To Sheet P m ft in. m ft In. ' 12 3,611 11 10 Z/8 11,346' 37 25/5 10 I5 4,572 15 0 14,363 47 14/8 10 18 5,486 18 0 17,236 56 f; s/e 12 21 6,401 21 0 20,109 65 115/0 14 24 7,315 24 0 22,981 75 4 G51 16 27 8;230 27 0 25,854 84 97/8 18 30 9,144 30 o 28,727 94 3 20 33 1 Q 058 33 o 31 599 103 61161 22 e) Two or three triches of sand is the best for your firer Using Band elimirates the necessity to level Inside of frame sroa except where exceptionally high or low areas GM - hot area must be firm and levet Theareas should ahher be dug or filled in. This does not mean the parfmeter or frame area. T Then by digging only. + d) Do not fill low spots In the area whers pool wall win rest. as setting may cause your pool to become out of Isvel. Making sure pod bottom is flat.Thls Is a must. site is not on firm " use Z- for the se the Well CAM dOA be nterapatio block under each bottom plate. Thtio e top of the �patio f blocks �d be flash with the prepared lard surface. 3) ASSEMBLING BOTTOM RAIL. STEP t:BeforpprocesdhV to the neat Step, place a targe amount before proceeding, remove the a way from Barton and sting 3'ato sifted earth to the nliddb of the circle. (sae chart for board trrskia pod area as shown act fight. Put the Mer. t7iav4r➢ It k In N the carton) the amount on the first page.) Irl" pod arse. 1 $TEP Z: Sifted earth should not contain'any pebbles. Iruran the bottom rafts around the entire perimeter using Iowan Joints on tie Place a patio block under each lower joint around curved circular portion of the pod. area. Leave one section open that will be nearest to where you ww locate your filter. 4 in 7' Top of patio block even with ground surface. Jul 09 03 03:32p Watsons 952 997 6866 p.5 ................................................................................................................. ........................................................................................................................................................................... IS) -HELPFUL INFORMATION Prof Miming and ebeRdwl treatments should not make It necessary to change the pod water. Your pool dealer will advise you of the proper proceduae, To esurnate the amount of dtenllcals needed hue is the approximate water content of the pool based on full capacity; Pool Size Capacity Poo! Size Capacity Ions allot 12x48 9,248 12x52 3,518 15 x 48 5,205 15 x 52 5,638 18 x 48 7,495 18 x 52 8,119 21 x48 10,201 21x52 11,051 24 x 48 13,324 24 x 52 14,435 27 x 48 16,863 27 x 52 18,269 30 x 48 20,819 30 x 52 22,554 33 x 48 25,191 33 x 52 27,290 Z. To help keep the pod clears and chW proof, a Pod stover should be on the pod whenever it Is not In use. This aim reduces loss of water and chemicals, To keep the pod In wwldrm condition dmek the foIlo ft operetlon, e) Leaks in skimnbr and Nter corneatkwu motet be atoppeA A constant drip of dnkxdmted water on instal will corrode the metal. b) Signs of eorroslon. trent be kmvAot* tapakV& Sand off the prat, Palet with rust resistant paint. c) d) The pod should be left uP and NW Year round prop4fy winterized and covered with a good cum. Ths water level must be lowered to about 6• below the lowest oldrn er opw*.V If your area is . subjected to be below freaft terrnperature. All pod leaks must be repaired befos winter. Do not empty Your pod In spring. Filtration and ehlodnatlon w9I remove aI 4tptaltles, Leaves and other matter should be skimmed or vacuuned out of dna pod. 5 ALL THESE POOLS ARE DESIGNED FOR SWIMMING ONLY. THEY MUST NOT BE USED FOR JUMPING OR DIVING, DO NOT JUMP DO NOT DIVE 1* PERMANENT INJURY OR.DEATH CAN RESULT 16) SAFETY RULES 1, Read your Instructions and safety rules carefully. if you do not follow the safety rules someone could be Inured or damage could occur. 2. Plan arefuly where you are going to put your pool, it must be close to • water smm* for filling. Also think about draining your pool. 3. Never let anyone swim alone. Children must be carefully watched. For added safety, install ■ Convex type mirror above pool to give full view of Interior. Available at., mirror dealers. 4. Do not let anyone rougWmusa In or wound your pool. The pool ansa and decks can be slippery. Someone could be badly injured. You can prevent this type problem by enfwmkv the safety nAes. S. Always keep the water dean and sanitary. Dirty water can be dangerous. Use your filter system. Follow Instructions included ur filter. with yolter. Also use water purifying chamlals as needed. 6. DO NOT DIVE OR AWJKrO YOUR POOL THE POOL IS NOT DESIGNED FOR DIVING OR JUMPING l 7. Renave ladders when there Is no adult to watch the pool. Repave anything g else that can be used gat into the pod. Use a cover If the pod Is not In use for a long period of time. SAFETY DECALS CAN BE AFFIXED TO A CLEAN, DRY,SMOOTH SURFACE SUCH AS THE VINYL LINER,TOP SEAT THAT HAS SMOOTH FINISH, THEY MUST BE PLACED THAT THEY ARE EASILY SEEN. Jumping and diving into a ASAHI CHEMICAUs Pool is STRICTLY FORBIDDEN. It is your responsibility as the owner of. -the pool to do the following: Do not locate pool near objects that would entice diving Le, garages, tree, porches, etc. Do rat let anyone use your pool unless they are fully aware of the DO NOT DIVE OR JUMP notice, Do not promote horse play or other activities that would cause Injuries. Do not allow -People to sit or walk on the top seat of.pw pool IT IS YOUR RESPONSIBILITY AS A POOL OWNER TO INSURE THE SAFETY OF WHOMEVER USES THE POOL NOT THE MANUFACTURER. READ ALL INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING YOUR POOL, Read through all instructions completely and famillarize yourself with all pool parts and accessories before pool assembly. Damage may be done if all Instructions are not carefully followed, and In such cases, will void manufacturer's warranty. When assembling pool, read through what you must do for each step, then proceed. WARNING THIS POOL IS DESIGNED FOR SWIMMING ONLY. IT IS NOT INTENDED FOR DIVING OR JUMPING. FOR A MAXIMUM OF SWIMMING FUN, BE SURE TO FOLLOW ALL SAFETY RULES WHEN USING ANY SWIMMING POOL.. Printed In JAPAN. Nov. 1999. Jul 09 03 03:33p Watsons 952 997 6866 p.6 ..... ... ... ... ... ... ... ... ... ... ... ... ... ...... ...... ...... ... ... ... ... ;.............................,..............................................................................................................,............................. ,� v._ ..r .. • o Wo�.SU11S OWNER'S GUIDE tu�A P R - 11#1 H.Ii O BY HAYWARD"' *SYSTEM LOCATION ./.JL JJ ! U a 0 0 ISSW1750MAR-00 Missile Element Filter System MODEL SW1750MAR SwimPro Element filters are high performance swimming pool litters with a filtration rating of 7,200 gallons (27.3 kl) per hour. Manufactured from durable, corrosion -proof materials, they ate designed for continuous or intermittent operation, for Installation below the pool water line, for fresh or sail wale., swimming pools or spas. Tho filters uIllize a reusable single element, reinforced polyester fillet cartridge u. provide a high degree of water clarity with absolute minimum care. Their unique design is such tial no wo.t. are needed to remove or replace the element in the filter assembly. Simply spin off the locking knao, 1111 ;il, the filter cover and remove the element. It's that easy. 1. Though the system is designed for outdoor use,it is advisable to protect electrical components from the weather. Select a well -drained area. one that will not flood when it rains. 2. For best pump performance, locate the system below the swimming pool water line. If the system must be located above the pool water line, it can be raised as high as 2 fest above the water. The pump strainer cover must be easily accessible for periodic cleaning. 3. Set the mounting platform level. Allow a minirribm top clearance for element removal. Be sure the pressure gauge and pipe connections, drain, etc. are accessible for convenient operation. 4. Position the system so the filter tank can be drained by gravity. 'Note: When installing filter system for standard pool operations, be sure to leave adequate clearances for the removal of fitter element (min. 28-11/2 inJ 73 cm) from filter and access to system components for ease of maintenance, serviceability, and proper ventilation. NOTE: ANSUNSPI-Article 4, standard -for above -ground . and on -ground pools, advises that components such as the filtration system,. pumps. eind heater be positioned so as to prevent their being used as a means. of access to the pool by young children. PLUMBING & INSTALLATION 1. Use 1-112" I.D. Iiexible plastic pipe or hose joined with Insert fittings aiV stainless steel clamps: or use nglo pipe with unions. 2. All plumbing connections, on the system are 1-1/2" N.P.T. When making connections, use p/as/icmale-end adapters. Apply three turns of Teflon tape or plastic pipe sealant to the male threads. Screw the fitting into the thread hand tight; than using a wrench, tighten one more full turn-. Additional tightening is unnecessary and could result in damage to components. 3. Refer to the diagrams for suggested valving. 8alf type valves are recommended where needed. 4. Tighten pump base mounting bolls, if loose 5. Securely hand tighten the union nut between the filter and pump. System Dimensions , MA":' _'77- 2002 09: 50 gS,) agry AAAA Height Length Width or Item Diameter i • IN. CM iN. CM IN.� ! CM Filter 43 109 14-1/2 37 13-:ve 34 ter Element 28-1/2 73 N/A 9 23 i I Pump 10-5/6 27 24 61 _• 8 i 21 Strainer I� Housing 10-s/a27 1 6-1/2 17 7-3/a 19 1 w/Cover 5-5/9 15 , Strainer Basket 7-1/2 19 N/A i Base 3-1/2 9 F31 -112L! 1 17-3-14 45 i MA":' _'77- 2002 09: 50 gS,) agry AAAA ...........Ju Jul 3.3p...................Watsons.........:.................................I................................95.2..._997....6866.....................................P..�. ............. 6. 7. 8. 9. Connect the pool suction plumbing between the skimmer, pool outlet, etc. and the pump. Install the pool return plumbing, It pressure gauge is not Installed, apply Teflon tape to the gauge threads, and carefully screw the gauge into the threaded hole In the filter head. A filter drain plug Is furnished with each filter and Is all that is needed for complete filter draining. A manuat air relief vitive is furnished to aid in bleeding oh unwanted air when starting the filter. The auto air relief provides air removal during operation. 10. All electrical connections should be made in accordance with local Rodes. ' 11. Check for joint leaks befdre operating. 12. Refer to pump instruction booklet for pump Information. SPECIFICATIONS MODEL NO. SW1750 EFFECTIVEPRESSURE FILTRATION AREA LOSS AT . DESIGN FLAW RATE . DESIGN FL.OWRATE MAXIMUM WORKING PRESSURE REQUIRED CLEARANCE SIDE ABOVE RESIDENTIAL PUBLIC AESIDENTIAL PUBLIC F r- M' 175 16.3 QPM LPM QPM LPM PSI BAR PSI BAR 120 454 60 227 6.0 .41 1.6 1.11 PS( a 50 3.45 CH CM INCH 16 48 30 CM 76 76 PARTS Model: SW1750MAR, SW1750MAR2S, SW1750MAR2SNTL, SW1750MAR2$N2, SW 1750MARTL REF. NO, PART NO. DESMIPT1oN No. 1 CX1750G Lo Knob 1 2 cx900H o• 1 3 CXWM Washer 2 4 CX90W E -Ring 1 5 Cx-mo Gine Cana 1 0 CX173M Rtar Head WDIrIgonel VeM Vd- 1 7 C900F Fillet Head 04N 1 a ' CX900MT mer Body --1 •til' FI P 1 0 ECX2709 Pramte Qmgv - 1 IOd CX1750RE Elamord 1 tt I cXt75027 Tia pod 1 Q CX1750Z4. Auto Air R" TWO 1 13 • Cx250Z/4 tl2• Drain Ph* 1 14 SPXGUZ2 oratn.Ptug OAfnp ' 15 sP1460 1•Iff union 0onnedM 1 IS ECX1322A DirealdW Vent Volvo w/o•Rhg 1 t 7 Power -Fla LX Pup 1 16 ECX11696$ 3 -Tier Base vAIi er t Is ECX13Ga Pwnp Mat"Ing Screw 1 20 ECX 1109 washer .2 27a SPX1500WA 0 % Gold Set 1 21 o sPxlswwA 3 h. cud Sol WTwisl•LOOk 1 MRY 17 2002 09:50 2 �b 18 • 952 997 6866 PAr;F. 1.7 Jul09 03....03..'..3.4p...................Watson.s.........:.............................,...................................95.2.....99.7....6866.....................................P.-.B............. ISE1541-99 HAYWARD ABOVE -GROUND, POOL PUMPS INSTALLATION AND OPERATION INSTRUCTIONS TM SERIES Your Hayward centrifugal pump has been quality -built and engineered to give you many years of efficient, dependable service. . The advanced design reduces operation and maintenance to simple, common-sense procedures, GENERAL TIPS ON PUMP INSTALLATION For best'pump performance, locate the system below the pool water line and as close to the pool as practical. Make sure suction joints are tight. Suction pipe should be as large or larger than discharge pipe. Damp, non -ventilated locatlons should be avoided. Motors require free .circulation of air to aid In cooling, Insure that the electrical supply available agrees with the motor's voltage, phase and cycle, and that wire size Is adequate for the motor rating and distance from power source. Motor must always be properly grounded, Use only a properly -grounded receptacle, Electrical circuits must be protected by proper size ground fault circuit interrupter (GFCI) ,as required by applicable electrical codes. All electrical wiring must be performed by qualified personnel, and must conform to local codes and regulations. MAINTENANCE 1. Clean strainer basket regularly►. Do not strike basket to clean. Inspect strainer cover gasket regularly and replace as necessary. 2. Hayward pumps have self-lubricating motor bearings and shaft seals, No lubrication is necessary. 3. Keep motor clean. Insure air vents are free from obstruction STARTING AND PRIMING INSTRUCTIONS Fill strainerthousing with water to suction pipe level. Never operate the pump without water..tWater acts as a coolant and lubricant for the medhanical shaft seal. Open all suction and discharge lines and valves, as well as air bleed (if available) on filter. (The air that Is to be displaced from the suction must have some place to go.) CAUTION: All suctlori and discharge valves must be open when starting the system. Failure to do so could cause severe personal Injury and/or property damage. Tum on power and allow a reasonable time for priming. Priming time depends on suction lift and horizontal length of suction piping. If the pump will not start, or will not prime, see TROUBLE SHOOTING GUIDE on back page. Note; ANSVNSPI-4 Article V, standard for above- ground and • on -ground pools, advises that components such as the filtration system, pumps and heater be positioned so as to prevent their being used as a means of access to the pool by young children. 4. Occasionally, shaft seals must be replaced, due to wear or damage. See Instructions, STORAGE/WINTERIZING Pump and motor must be protected from freezing. Shut off all electrical power: - Disconnect cord/electrical connections and plumbing connections. Drain thoroughly and clean out any debris. Store pump and motor in a dry, well -ventilated room. Jul....09... 03.....03.=..3.5p...................Watsons......................................,...................................95.2....997....6866.....................................1°....9....... ... ... SEAL CHANGE. INSTRUCTIONS EP SERIES GENERAL Exercisq extrame care in handling and Installing the new seal and sear assembly. The lapped and polished surfaces may easily be damaged by dirt or scratching. For safety, all service must be performed with all Hower shut off, 1. Remove pump and motor assembly from piping 7. system. 2. Remove pump housing cover (with strainer attached) by removing the seven or eight (7 or 8) housing.bolts and nuts which fasten housing cover to pump housing. The Impeller is now exposed. 3. To remove impeller, Insert screwdriver In slot at end of motor. Hold screwdriver so as to keep shaft from turning, and rotate the impeller in a counterclockwise direction. The spring portion of the seal assembly is now exposed. 4. Note carefully the position of the spring seal and pull It off the impeller. 5. To remove the stationary (ceramic seat) part of the seal assembly: Press the new spring portion of the assembly onto the impeller, black polished surface facing away from the impeller. 8, Carefully press ceramic seat, with 0 -ring, Into clear plastic seat retainer—polished surface facing out. Be sure black rubber 0 -ring Is in place on cut ridge of clear plastic seat retainer. Press plastic retainer, with ceramic seat Inside, Into recess of pump housing -0 -ring end first. Seat the assembly firmly and evenly, using finger pressure. 9. Carefully insert the motor shaft through the seat assembly, and secure motor to pump housing with four (4) motor securing bolts. (Be sure motor base Is positioned properly). 10. Screw the impeller, with spring seal, onto the motor shaft, hand tight, by turning clockwise. a. Loosen the four (4) motor securing bolts and 11. disengage the motor from the. pump housing, b. With motor removed, press the clear plastic and ceramic seat assembly out of the pump housing recess. If tight, tap lightly from the "motor" side. 6. Clean and lubricate the impeller hub shaft and pump housing seal recess with a dilute solutlon of non• granulated, liquid -type soap. The use of petroleum or silicone lubricants can contribute to seal. leakage, Clean fiber gasket (replace If necessary) and fasten housing cover to pump houslpg with seven or eight (7 - or 8) bolts and nuts, Tighten bolts and nuts alternately and evenly. 12. Reconnect pump to piping system. Be sure to fill strainer with water before restarting. ELECTRICAL GUIDE -- 60 CYCLE MOTORS , SINGLE PHASE MOO SPL GPM VOLTS CIRCUIT BREAKER RATINGS—AMPS BRANCH FUSETRON RATINGS -AMPS RECOMMENDED WIRE SIZE 0-50, 34 50 115 10 10 #14 1 60 116 1*6 15 414 1-1/2 70 116 15 15 #14 A separate electrical circuit, utilizing a rating as above, Is recommended. yy\ \\\D-\Q\C) 5S - CITY OF FRIDLEY INSPECTION DIViSION 6431 University Ave NE Z� Fridley, MN 55432 Qi�1.jj APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, (763) 572.3604 t; REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES RATE SCHEDULE Residential Furnace Shell and Duct Work, Burner - Also Replacement Furnace (Side Vent - Fill Out Back) Gas Piping (Needed with new furnace, but not replacement) Gas Range Gas Dryer *Air Conditioning - All Sizes All Others/Repairs & Alterations (LIST ON BACK) 1% of Value of Appliance or Work Commercial/Industrial 1.25% of Value of Appliance or Work Rate $ 30.00 $ 10.00 $ 10.00 $ 10.00 $ 25.00 State Surcharge TOTAL FEE MINIMUM FEE FOR ANY HEATING/COOLING/VENTILATION REFRIGERATION/AIR CONDITIONING PERMIT IS $25.00 PLUS THE $.50 STATE SURCHARGE REINSPECTION FEE $47.00/Hr *Air Conditioners can not be placed in a side yard without written permission from adjoining property owner. JOB ADDRESS Effective On January 1, 2002 OWNER L loneA ! l �� `TOTAL $^� BUILDING USED AS C� ESTIMATED COST nn PERMIT NO. DESCRIPTION OF FURNACE AND OR BURNER No. of Heating Units Circle One (Steam) (Hot Water (Warm Air $ Trade Name WjL Size No. BTU �C�� HP EDR $s^7��d2b Fuel Gn _S Total Connected Load Burner Trade Name Size No. $ BTU HP EDR $ The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the City Codes an $ .50 rulings of the Building Division, and hereby declares that all the facts and $ S representations stated in this application are true and correct. v DATE ll � � HEATING CO A � Signed TEL #W -7)S-1- S® FAX # Approved By Rough -In Date Final Dated �� G( THE BELOW MUST BE FILLED IN WHEN REPLACING FUEL BURNING APPLIANCES OR THE APPLICATION WILL BE RETURNED COMMON VFNT, VFNT CnNNFCTnR ANn COMM 1STlnN AIR VFRIFICATInN When reISA an existing furance, the undersigned hereby verifies that the venting has been examined and is free from rust, deterioration, obstructions, and is securely supported and firestopped where required. Yes V No( ) The venting system is plastic/PVC and meets all current codes and manufacturer specifications including sizing, length, number of elbows and termination. Yes( ) No( ) The undersigned also verifies that the replacement unit is a listed assembly and meets the current codes and manufacturers specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes No( ) The existing come ,c ion air is sized and installed to meet the current codes and manufacturers specifications. YesX)No ( ) When required to install a new comb nstion air.,it will be sized and installed to meet the current codes and manufacturer's specifications. Yes ) No( ) When installing a new venting system, the undersigned hereby verifies that it is a listed assembly and meets the current codes and manufacturer's specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) Is the common vent and vent connectors sized and installed correctly after an appliance has been removed from the common vent and vented separately as per current codes. YeskNo ( ) Appliance #1 Type -7a tyo o BTU Input �— Fan Assisted or Nat Appliance #2 Type ? 2� 4-0c:> BTU Input Fan Assisted or Nat X Appliance #3 Type BTU Input Fan Assisted or Nat Total Appliances Total Btu Input Common Vent Type :;,s i( Vent Height �-� Diameter 13- inches Appliance #1 Vent Connector Height __Z ft Length ft Diameter in Type 6 Appliance #2 Vent Connector Height _j,_ft Length _ j _ft Diameter in Type (2 - Appliance #3 Vent Connector Height ft Length ft Diameter in Type SignedHEATING CO: �� *. Building $ BUILDING $ Permit No.: d� - Inspections Surcharge RESIDENTIAL APPLICATION License Surcharge Received By: 763-572=3604 $ CITY OF FRIDLEY $ '�Lz ) DatWOd o% DATE APN L I 1 200 7 YOUR E-MAIL ADDRESS qJ 1111 [J LI ® Lo V -N SITE ADDRESS 031 '7 'T%A SS 4E - E -THIS Total Due THIS APPLICANT IS: Jill OWNER ❑CONTRACTOR r PROPERTY OWNER/ NAME: L1;4W L 7Z( 0, c� ADDRESS: 5 q) 1 -7113 L-1, ME CITY Sek1 A L 0i STATE14t ZIP `' 2 ) I i 2 y TENANT PHONE: 71rn —71—'�9 j Bio CONTRACTOR NAME: STATE LICENSE # EXP DATE SUBMIT A COPY OF YOUR STATE LICENSE ADDRESS: CITY STATE ZIP WITH APPLICATION PHONE FAX PROPERTY TYPE !a SINGLE FAMILY/NEW CONSTRUCTION SIZE ❑ TWO FAMILY/NEW CONSTRUCTION STORIES PERMIT TYPE ❑ ADDITION ❑ GARAGE/SHED ❑ WINDOWS ❑ BASEMENT FINISH ❑ ROOF ❑ DRAIN TILE ❑ DECK ❑ SIDING ❑ OTHER ❑ SWIMMING POOL TYPE OF WORK: ❑ NEW ❑ ADDITION ❑ MAINTENANCE/REPAIR ❑ REMODELING DESCRIBE WORK BEING DONE: G01 SIZE OF IMPROVEMENT LENGTH WIDTH HEIGHT Sq. Ft. ROOFING ❑ HOUSE ONLY NUMBER OF SQUARES ❑ HOUSE & GARAGE BASEMENT REMODELING SUBMIT: GARAGES ❑ ATTACHED GARAGE 1. 2• Existing Floor Plan Proposed floor plan PROPOSED SIZE: ❑ DETACHED GARAGE 3. List of structural members to be used PROPOSED HEIGHT: SIDING FOR NEW CONSTRUCTION INCLUDING DECKS, ❑ Vinyl ❑Soffit ADDITIONS. & PORCHES SUBMIT: ❑ Aluminum ❑ Trim 1. Site Plan/Survey showing the existing structures ❑ Other . ❑ Fascia and proposed project 2. Two sets of construction plans WINDOWS 3. Energy Calculations IN EXISTING OPENINGS ❑Yes ❑No LOCATION OF WINDOWS OR FOR NEW OPENINGS -DESCRIBE SIZE OF OPENING CHANGES & TYPE OF WINDOW TO BE INSTALLED NUMBER OF WINDOWS ALL FEES ARE BASED ON VALUATION, INCLUDING THE COST OF LABOR AND MATERIALS: (USING THE 1997 U.B.0 FEE SCHEDULE) TOTAL JOB VALUATION $ OCCUPANCY_ TYPE Permit Fee $ Plan Review $ Fire Surcharge $ Surcharge $ License Surcharge $ SAC Charge $ Curb Cut Escrow $ '�Lz ) Erosion Control $ Park Fee $ Sewer Main Charge $ Total Due $ See Back Page for Fee Schedule 65% of Building Permit Fee .001 times the total job valuation .0005 x Permit Valuation Minimum $.50 $5.00 (State Licensed Residential Contractors) $1675 per SAC Unit (Plans to MWCC for determination) -ft+aft= 11 ftx$21=$2.3)a' $450 Conservation Plan Review Fee Determined by Engineering Agreement necessary ( ) Non Necessary ( ) Make checks savable to: City of Fridley Attach THIS IS AN APPLICATION FOR A PERMIT -NOT VALID UNTIL PROCESSED I hereby apply for a building permit and I acknowledge that the information above is complete and accurate; that the work will be in conformance with the ordinances and codes of the City of Fridley and with the Minnesota Construction Codes; that I understand this is not a permit but only an application for a permit and work is not to start without a permit; that the work will be in accordance with a approved plan in the case of all work which requires nd approval of plans. 1 n I SIGNATURE OF APPLICANT `"�� ,� PRINT NAME