Loading...
PRE 2010 DOCS01 suejEcr IT NO. City of Fridley (, 31294 AT THE TOP OF THE TWINS BUILDING PERMIT r RECEIPT NO. � 1 � ______ COMMUNITY DEVELOPMENT DIV. INSPECTION SEC. /41 r I PROTECTIVE 1 . � ".--I CITY HALL FRIDLEY 55432 14UEIOEFI REV DATE PAGE OF AOPROVEO Br %.4 612-571-3450 910-F15 8/10/00 JOB ADDRESS 6330 7 Street NE 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 14 1 1 Alice Wall Addition SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Robert Granger 6310 7 Street NE, Fridley, MN 55432 763-502-0694 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO B USE OF BUILDING Residential 7 CLASS OF WORK NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE B DESCRIBE WORK Construct a 50' x 38' Dwelling; a 24' x 26' Garage; and a 16' x 10' Deck 9 CHANGE OF USE FROM TO STIPULATIONS See notations on plan. Provide City with copy of verifying survey before capping. Provide sod in the front and side yards. Provide a hard surface driveway. See Engineering Department for Sewer & Water Locations. Driveway Curb Cut: 20' + 6' = 26' x $15.50 = $403.00 WARNING SEPARATE PERMITS Before digging call for all utility locations REQUIRED FOR: 454.0002 RING HEATING REQUIRE® BY LAW PL AND SIGNS SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT CU FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT R-1 ANY TIME AFTER WORK IS COMMENCED. NO DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND VALUATION SURTAX Fire SC ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $137,388 $68.69 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVIS NY OTHER ST OR LOCAL LAW REGULATING CON- $1,206.55 1,100 STRU 10 OR T E PERFO NCE F CONSTRUCTION F PLAN CHECKTOTAL FE �(� $2, 2.62 + DW AGNURE Oc A Op AUTHO_AteVAG T (DATE, IS PERM MROPERDATEDI L/�1,�J.e iq S.GNATURE OF OWNER,1F OWNER BUILDERS 10ATE1 J�� BLD -NSP r�ATE 01 NEW (] Effective 1/1/2000 ADDN [ ] CITY OF FRIDLEY (763) 57 g Insp ALTER [ ] SINGLE FAMILY AND DUPLEXES R-1 AND R-2 r*a BUILDING PERMIT APPLICATION Construction Address: .Jj o 744 `"% 1y, Legal Description: L?/ - 4 ek A,L ;'e e_ ilo � Z A d ct; r d:_1 Owner Name & Address: ^ ®1?` .t ' r�4 i1/ �2 P F- Tel. # Ica 6C'1 - C7 Z' 17�' Contractor: s e ,C T MN LICENSE # Address: / /D - 7 2� ' i AZ% Fes, Tel. # (,/;z- t,: -e,2 ^0d, %!v Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF IMPROVEMENT LIVING AREA: Length S Width 49 Height Sq. Ft. i GARAGE AREA: Length Width Height Sq. Ft. DECK AREA: Length Width �� f Hgt/Ground 2 Sq. Ft i OTHER: l V/37.368"S '91 Construction Type: IyIe Z-) Estimated Cost: $ - ls� Driveway Curb Cut Width Needed: + 6 F = Ft x $ _ $ DATE: 7—c1 APPLICANT:Tel. .56� CITY USE ONLY - Call (763) 572-3604 for Permit Fees if mailing in application Permit Fee $ , ,Fee Schedule on Reverse Side Fire Surcharge $ /37.3S .001 of Permit Valuation (1/10th%) State Surcharge $.50/$1,000 Valuation SAC Charge $ / / Ij2 . ®L $1100 per SAC Unit License Surcharge $. $5.00 (State Licensed Residential Contractors) Driveway Escrow $ Q Alt. "A" or Alt. "B" Above Erosion Control $ $450.00 Conservation Plan Review Park Fee $ _ Fee Determined by Engineering_ Sewer Main Charge $ Agreement Necessary [ ] Not Necessary [ ] TOTAL STIPULATIONS: Exterior Envelope Thermal Transmittance Worksheet SITE ADDRESS CITY PLAN #2003 TIM BRUMMER 7/25/00 ASSEMBLY AREA U -Factor U -Factor 73.043 Sq. Ft. Insulated Area x Area If C is greater than D, or G is greater than H, revise the design as necessary to meet the envelope criteria of the Energy Code. 1) U -factor for skylight and window must be determined by the National Fenectration Rating Council Standard 100-91 or ASHRAE 1993 Handbook of Fundamentals, Chapter 27, table 5. 2) Thermal Transmittance of opaque components (including integrally insulated masonry and metal stud framing) - use part 7670.0450, subpart 4. Insulated Area 2 1680.000 .043 73.043 Insulated Area 1719.000 .022 37.549 c Framing Area .000 .025 .000 c Skylight .000 .136 .000 _ Other 1900.000 .041 .000 co Fireplace Wall .000 Above Grade Foundation Wall 360.000 .048 .000 Foundation Windows 59.200 .330 .000 -� PATIO DOOR 46.700 .320 .000 .000 _ Totals A 1719.000 B 37.549 aD Average U -Factor B 37.5491481 /A 1719 G .022 .000 v Required U -Factor (from Energy Code): Q .026 .000 If C is greater than D, or G is greater than H, revise the design as necessary to meet the envelope criteria of the Energy Code. 1) U -factor for skylight and window must be determined by the National Fenectration Rating Council Standard 100-91 or ASHRAE 1993 Handbook of Fundamentals, Chapter 27, table 5. 2) Thermal Transmittance of opaque components (including integrally insulated masonry and metal stud framing) - use part 7670.0450, subpart 4. Insulated Area 2 1680.000 .043 73.043 Framing Area 2 .000 .092 .000 Windows ' 289.250 .290 83.883 _ Doors .000 .136 .000 _ Rim Joist 1900.000 .041 77.741 co Fireplace Wall .000 Above Grade Foundation Wall 360.000 .048 17.176 Foundation Windows 59.200 .330 19.536 -� PATIO DOOR 46.700 .320 14.944 .000 .000 c .000 a .000 X .000 LU .000 Totals E 4335.150 F 286.323 Average U -Factor F 286.3229583 /E 4335.15 IG .066 Required U -Factor (from Energy Code): .110 If C is greater than D, or G is greater than H, revise the design as necessary to meet the envelope criteria of the Energy Code. 1) U -factor for skylight and window must be determined by the National Fenectration Rating Council Standard 100-91 or ASHRAE 1993 Handbook of Fundamentals, Chapter 27, table 5. 2) Thermal Transmittance of opaque components (including integrally insulated masonry and metal stud framing) - use part 7670.0450, subpart 4. Form for use with Minnesota Rules part 7670.0475, Subp.2 1 & 2 Family Residential "Cookbook" Method SITE ADDRESS CITY BOB GRANGER 1680.000 BUILDER DATE BOB GRANGER 7/25/00 Minimum Criteria: Rim Joist: R-19 insulation Foundation Windows: Insulated glass, 1/2" air space, wood or vinyl frame Entry doors: 1-3/4 inch solid wood with storm or better N IER Total Area of Windows & Doors 289.250 From the table, determine the maximum percent BOX A window & door area for the design options selected Total Wall Area in Sq. Ft. and enter the value in box D below: Wall Total Perimeter Height Area 1.000 STEP 1 Window & Door Area 8.000 1680.000 STEP 2 Calculate area as a percent of wall Total Window & Door Area Sq. Feet Box A (window & door area)divided by Box B(total 0.000 WINDOWS (including foundation windows): 1.000 wall area) times 100 equals the window and endow Dimensions Qty Area door area as a percent of wall area (BoxC) RONT 0.000 0.000 1.000 92.000 Box A 289.250 x100= 17.21 SIDE 0.000 0.000 1.000 55.000 Box B 1680.000 Box C EAR 0.000 0.000 1.000 110.500 STEP 3 Design Features SIDE 0.000 0.000 1.000 31.750 ASSEMBLY OPTION 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 FRAME WALL: 0.000 0.000 0.000 0.000 STANDARD FRAMING X 0.000 0.000 0.000 0.000 ADVANCED FRAMING 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 CAVITY INSULATION R- 19.000 Total Window Area 289.250 SHEATHING: DOORS: LESS THAN R-5 X 0.0001 0.000 0.000 0.000 R-5 OR MORE 0.0001 0.000 0.000 0.000 0.0001 0.000 0.000 0.000 WINDOWS(EXCEPT FOUNDATION WINDOWS): Total Doors Area 0.000 U -FACTOR U- 0.330 N IER Total Area of Windows & Doors 289.250 From the table, determine the maximum percent BOX A window & door area for the design options selected Total Wall Area in Sq. Ft. and enter the value in box D below: Wall Total Perimeter Height Area 1.000 210.000 8.000 1680.000 0.000 0.000 1.000 0.000 0.000 0.000 1.000 0.000 0.000 0.000 1.000 0.000 1680.000 BOX B 18.800 BOX D Box C must be less than or equal to Box D Assembly R and U -Factor Forms ASSEMBLY ROOF @ FRAMING Material (Describe) Material (Describe) Thickness R -Value Interior Film Coefficient .680 .610 5/8" Sheetrock 19.000 .560 3-1/2" Truss 1.890 6.870 Insulation Balance 2.090 31.166 Vinyl Siding .610 .610 Exterior Film Coefficient .610 Total Assembly Thermal Resistance 39.816 Assembly U -Factor (1/Total R) .025 ASSEMBLY WALL @ FRAMING Material (Describe) Material (Describe) Thickness R -Value Interior Film Coefficient .680 .680 1/2" Sheetrock 19.000 .450 5-1/2" Stud 1.890 6.870 25/32" Wall Shtg 2.090 2.090 Vinyl Siding .610 .610 Exterior Film Coefficient .170 Total Assembly Thermal Resistance 10.870 Assembly U -Factor (1/Total R) .092 ASSEMBLY WALL @ RIM Material (Describe) Thickness R -Value Interior Film Coefficient .680 5-1/2" Insulation 19.000 1-1/2" Joist 1.890 25/32" Wall Shtg 2.090 Vinyl Siding .610 Exterior Film Coefficient .170 Total Assembly Thermal Resistance 24.440 Assembly U -Factor (1/Total R) .041 ASSEMBLY ROOF @ INSULATION Material (Describe) Thickness R -Value Interior Film Coefficient .610 5/8" Sheetrock .560 12" Insulation 44.000 25/32- Wall Shtg 2.090 Vinyl Siding .610 Exterior Film Coefficient .610 Total Assembly Thermal Resistance 45.780 Assembly U -Factor (1/Total R) .022 ASSEMBLY WALL @ INSULATION Material (Describe) Thickness R -Value Interior Film Coefficient .680 1/2" Sheetrock .450 5-1/2" Insulation 19.000 25/32- Wall Shtg 2.090 Vinyl Siding .610 Exterior Film Coefficient .170 Total Assembly Thermal Resistance 23.000 Assembly U -Factor (1/Total R) .043 ASSEMBLY EXPOSED BLOCK WALL Material (Describe) Thickness R -Value Interior Film Coefficient .680 5-1/2" Insulation 19.000 12" Conc. Bilk. 1.110 Exterior Film Coefficient .170 Total Assembly Thermal Resistance 20.960 Assembly U -Factor (1/Total R) .048 CERTIFICATE OF SURVEY FOR BOB GRANGER CONST. (MEASUREMENTS SHOWN IN FEET AND DECIMALS OF A FOOT) ` THIS IS NOTA BOUNDARY SURVEY " I HEREBY CERTIFY THAT THIS PLOT PLAN WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION . THAT THIS PROPOSED PLAN CORRECTLY SHOWS THE PLACEMENT OF A PROPOSED GRADES BUILDING ON THE LAND HEREON DESCRIBED AND THAT I AM A DULY L I CENSED LAND SURVEYOR UNDE 'THE LAWS STATE MI I�IESOTY 't/n GARAGE SLAB Randy L. Kurth, L.L.S. No. 20270 TOP OF BLOCK = a`� �•°� Russell J. Kurth. L.L.S. No. 16113 BASEMENT FLOOR K. = g 3 -v (3¢0) 0 20 s6Nc4*1 i� ? {a v ► H`1 i7 b32o `� 1` M Qtr S (Rni) CL`,4�,.,10� Z - S 1= SCALE IN FEET I.5\�/ -rDP Li-je� 35 _-_2-- -� 8'1890 5 9' 33 E 1 2 0 .0 1 ______ - 6�5 � _ 25.66 (SLR 1 r, SLRIL I I . IC 4002 JEFFERSON ST. N.E. COLUMBIA HEGHTS, MN. 55421 (612) 788-9769 FAX (612) 788-7602 DATE ,'7-XCKD - 0 = IRON MONUMENT BEARINGS ARE PER PLAT • = SPIKE SET EXISTING ELEVATION ( ) = PROPOSED ELEV. F— = DRAINAGE ARROW 1------------------------ - 24.33 Q O 24 - O lA z W En � � a 1"1 15.67 PROPOSED O IN I' O p HOUSE ; v O `c O I. - (.�vCL 5 5 2 342 11 i 3 v7 J �N NSI. wn x �N f Q � � 99 3.25- 2 _ I, O z '---1 ----------------- ------ -.1, �L 24.67 9° 1 2 0. 0 1 7 I � Lot 14, E5lock I, &Tf-: 096.4 gcCl F,4 Alice Wall Addition, Anoka County, Minnesota t ;tco Qun, ,� P&4r- by4s.)LOVA , ww Fil W V/ W r � Alice Wall Addition, Anoka County, Minnesota t ;tco Qun, ,� P&4r- by4s.)LOVA , CITY OF FRIDLEY INSPECTION DIV. 6431 University Ave NE Fridley, MN 55432 572-3604 APPLICATION FOR PLUMBING AND GAS FITTING PERMIT MARK NUMBER OF FIXTURES TO BE INSTALLED ON EACH FLOOR Effective On Jan 1, 2000 PLUMBING FIXTURE RATES: NO. RATE TOTAL JOB ADDRESS New Fixtures Old Opening, New Fixture Beer Dispenser Blow Off Basin Catch Basin Rain Water Leader Sump/Receiving Tank Water Treating Appliance Water Heater -Electric Water Heater - Gas** Gas Range** Gas Dryer** Back Flow Preventer Required ( )Yes () No Type $ 7.00 91116_e $ 4.00 $ 5.00 $ 7.00 $ 7.00 $ 7.00 $ 7.00 $10.00 $ 7.00 $10.004 4 d $10.00 $10.00 $15.00 Reinspection Fee $47.00/Hr ALL OTHERS AND/OR REPAIRS AND ALTERATIONS 1.5% of Value of Fixture or Appliance State Surcharge $ _50 TOTAL FEE $ /®(-S� The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the city codes and rulings of the Building Division, and hereby declares that all the facts and representations stated in this application are true and correct. l r , 200 e Owner Building Used As Estimated Cost PERMIT NO. 4/0 PLUMBING COMPANY 0_RP44v­✓"`"�- SIGNED BY Approved COMBUSTION AIR SHALL BE PROVIDED PER UMC SECTION 504(A) AND TABLE 6-A. COMMON VENT INFO ON BACK SIDE COMMON VENT, VENT CONNECTOR AND COMBUSTION AIR VERIFICATION When replacing an existing furance, the undersigned hereby verifies that the venting has been examined and is free from rust, deterioration, obstructions, and is securely supported and firestopped where required. Yes () No ( ) The venting system is plastic/PVC and meets all current codes and manufacturer specifications including sizing, length, number of elbows and termination. Yes () No ( ) The undersigned also verifies that the replacement unit is a listed assembly and meets the current codes and manufacturer's specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) The existing combustion air is sized and installed to meet the current codes and manufacturer's specifications. Yes( ) No( ) When required to install a new combustion air, it will be sized and installed To meet the current codes and manufacturer's specifications. Yes( ) No( ) When installing a new venting system, the undersigned hereby verifies that it is a listed assembly and meets the current codes and manufacturer's specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) Is the common vent and vent connectors sized and installed correctly after an appliance has been removed from the common vent and vented separately as per current codes. Yes( )No( ) Appliance Type and Size/Common Vent and Vent Connector Information Appliance #1 Type BTU Input Fan Assisted or Nat Appliance #2 Type BTU Input Fan Assisted or Nat Appliance #3 Type BTU Input Fan Assisted or Nat Total Appliances Total Btu Input Common Vent Type Vent Height Diameter inches Appliance #1 Vent Connector Height ft Length ft Diameter in Type Appliance #2 Vent Connector Height ft Length ft Diameter in Type Appliance #3 Vent Connector Height ft Length ft Diameter in Type ALTERATIONS: (Describe) HEATING CO: Signed By: Date: CITY OF FRIDLEY INSPECTION DIViSION 6431 University Ave NE Fridley, MN 55432 APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, 572-3604 REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES RATE SCHEDULE Residential Furnace Shell and Duct Work, Burner - Also Replacement Furnace (Side Vent - Fill Out Back) Gas Piping (Needed with new furnace, but not replacement) Gas Range Gas Dryer *Air Conditioning - All Sizes All Others/Repairs & Alterations (LIST ON BACK) 1% of Value of Appliance or Work Commercial/Industrial 1.25% of Value of Appliance or Work Rate $ 30.00 $ 10.00 $ 10.00 $ 10.00 $ 25.00 State Surcharge TOTAL FEE MINIMUM FEE FOR ANY HEATING/COOLING/VENTILATION REFRIGERATION/AIR CONDITIONING PERMIT IS $25.00 PLUS THE $.50 STATE SURCHARGE REINSPECTION FEE $47.00/Hr *Air Conditioners can not be placed in a side yard without written permission from adjoining property owner. TOTAL $ ��• acs $ Coo JOB Al OWNE BUILD ESTIMATED COST Effective On January 1, 2000 PERMIT NO. o o DESCRIPTION OF FURNACE AND OR BURNER No. of Heating Units cle One (Steam) (Hot Water) (Warp,<Air) $ Trade Name /1.- Size No. P5 BTU 61_, HP EDR Fuel T al Connected Load Burner Trade Name Size No. $ BTU HP EDR $ The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the City Codes an $ .50 rulings of the Building Division, and hereby declares that all the facts and representations stated in this application are true and correct. DATE H EATI Signe 01 Ar TEL #4Z2 Approved By Rough -In Date Final Date COMMON VENT, VENT CONNECTOR AND COMBUSTION AIR VERIFICATION When replacing an existina furance, the undersigned hereby verifies that the venting has been examined and is free from rust, deterioration, obstructions, and is securely supported and firestopped where required. Yes () No ( ) The venting system is plastic/PVC and meets all current codes and manufacturer specifications including sizing, length, number of elbows and termination. Yes () No ( ) The undersigned also verifies that the replacement unit is a listed assembly and meets the current codes and manufacturer's specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) The existina combustion air is sized and installed to meet the current codes and manufacturer's specifications. Yes( ) No( ) When required to install a new combustion air, it will be sized and installed To meet the current codes and manufacturer's specifications. Yes () No ( ) When installing a new venting system, the undersigned hereby verifies that it is a listed assembly and meets the current codes and manufacturer's specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) Is the common vent and vent connectors sized and installed correctly after an appliance has been removed from the common vent and vented separately as per current codes. Yes( ) No ( ) Appliance Type and Size/Common Vent and Vent Connector Information Appliance #1 Type I BTU Input Fan Assisted or Nat Appliance #2 Type BTU Input Fan Assisted or Nat Appliance #3 Type -BTU Input Fan Assisted or Nat Total Appliances Total Btu Input Common Vent Type Vent Height Diameter inches Appliance #1 Vent Connector Height ft Length ft Diameter in Type Appliance #2 Vent Connector Height ft Length ft Diameter in Type Appliance #3 Vent Connector Height ft Length ft Diameter in Type ALTERATIONS: (Describe) HEATING CO: Signed By: Date : -PC�/� Haukaas, Jon From: Haukaas, Jon Sent: Thursday, October 19, 2000 4:17 PM To: Bums, Bill Cc: Julkowski, Ron; Dacy, Barb Subject: 6330 7th Street Bill Here is the sequence of events regarding the property a , 7th 8treet.- Mr. Granger came in some time ago for information on sewer and water connections for theis property. We provided him with the as -built information we have on file - this is standard practice. We do not guarantee the information and warn the builder to verify it in the field. Mr. Granger came back later with his house survey when he was preparing to build. He asked how deep the sewer connection was. The information on the sewer plan stated the sewer invert was at 846.12 ft and the information on his house survey stated the sidewalk elevation was at 854.7 ft. From this we showed him that the sewer depth should be about 8 1/2 feet deep at the sidewalk. When the sewer connection was being done, Mr. Granger came to inform us that the sewer stub was not at the depth we specified. I met with him on site. The contractor doing the work explained that the service form the house came out too low to connect to the sewer stub. It was not exposed at the time and no one ever verified the exact elevation of the stub. At that time, before lunch that day, I explained that the main line sewer was 3 feet farther out and 2-3 feet deeper and would work. It would not require any excavation in the street and he had permission to connect directly to it. The "Gopher State One -Call" marks were still clearly visible on the ground showing the location of the mainline. They chose not to do the work at that time. On October 3, the owner of the contracting outfit doing the utiltiy connections called and asked how to connect to the sewer. I gave him the same information. He later went back and completed the work. A direct tap into the top of the 15 Corrugated Metal Pipe mainline sewer that had been Insituform lined a few years ago. Our personnel inspected the tap and there were no problems. One of my concerns on the whole thing is if it would have worked in the first place. The top of the basement slab was at 848.5. The bottom to the slab is then 848.0. The bottom of the footings would then be 847.0 The sewer stub was 50 feet from the front of the house. Sewer services are run at a minimum slope of 1/4" per foot. That equals 12.5". If the top of the 4" service was actually touching the bottom of the footing at the front of the house, the bottom of the pipe was 846.66 and after 50 feet the bottom of the service pipe would be at 845.6 - lower than the information on the stub provided. It wouldn't have worked anyway. We gave him the best solution to a problem of his own creation. Let me know if you need more information. JovvU ffa u xcacw CIiYOF FRIDLEY FRIDLEY MUNICIPAL CENTER - 6431 UNIVERSITY AVE. N.E. FRIDLEY, MN 55432 - (763) 571-3450 - FAX (763) 571-1287 May 28, 2002 Mr. Robert Granger 6330 7 Street NE Fridley, MN 55432 Re: Final Inspection at 6330 7 Street NE, Fridley Dear Mr. Granger: A final inspection was conducted on May 28, 2002 for the construction of the house and garage at the above address. The inspection noted that the construction was completed according to the approved plan and occupancy of the building is approved. If you have any questions concerning this matter, please feel free to contact me at 763-572-3602. Sincerely, RJ/mh