Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PRE 2010 DOCS
City of Fridley SUBJECT PE - .®141'7 AT THE TOP OF THE TWINS PERMIT Ir i. BUILDING RIPT ` ___� COMMUNITY DEVELOPMENT DIV. L 8 -7Ml 1 PROTECTIVE INSPECTION SEC. .97rq NUMBER REV. DATE PAGE OF APPROVED BY CITY HALL FRIDLEY 55432 612-560-3450 910-F15 6/20/77 JOB ADDRESS 1581 - 73� Avenue N.E. 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 3 1 tK Deleir Addition SHEET 2 PROPERTY OWNER MAILADDRESS ZIP PHONE Elmer P. Israelson Jr. 1619 - 73rd Avenue N.E. 784-6991 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 6 USE OF BUILDING ` Residential 7 CLASS OF WORK NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOV 6 DESCRIBE WORK dkog call local Ut Construct a 42' x 26' Dwelling and a 22' x 24' Garage .Before FOR WIRING, REQUIRED BY 6 9 CHANGE QF USE FROM T 'nNt p1 t11M8ING AND %IGNS. STIPULATIONS Provide a hard surface driveway. Provide a verifying survey before capping. Provide sod in the front and side yards. Builder is to contract City Engineering Dept. to verify his proposed footing elevations. Provide City with. copy of truss design. SEWER & WATER NOT AVAILABLE YET 30 DAY NOTICE TO CITY ENG. DIV. NEQUIRED FOR CURS TIS C" Of MIN DIM KOT GUARA N Ta .ACCURACT OF VOW ILGIU r M AIS MASON & RIUMOVAL AND REPLACEMENT THIS DATA li FOR WOWATbN PUP0313 Of4y AM AT DRIVEWAY OPENINGS. PERSONS USING R SHOULD vFmFy THE INPOftaoN ON TM 5tm SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD VENTILATING OR AIR CONDITIONING. Wood Frame THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SQ. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT R-1 1134+528 27,624 Tot ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION ] STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED $34,450 $17.23 WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIONS OF ANY O ER STATE OR LO L LAW REGULATING CON- $110.50 $375.00 STRUCT N OR THE PER RMANC OF CO S U TION. PLAN CHECK FEE TOTALFEE $27.62 $530.35 SIGNATURE OF CONTRACTOR OR AUTHORIZED AG T IDA,EI PER Y VALIDATED THIS IS/YOU PER)AIT HYIN j BLDG SP GATE SIGNATURE OF OWNER IIF OWNER BUILDER) (DATE) hies Etc. N CITY OF FRIDLEY APPLICATION FOR RESIDENTIAL BUILDING PERMITS (NEW, ALTERATIONS, ADDITIONS, OR REPAIRS) OWNER: � �� �(` m� ��t I 0)1 ,BUILDER: W1�y° T'S Address: A Q /Y Address: �-j _ No.. P Tel. No. / r5 8 r/ Street: u e- • �� � LOT: 3 BLOCK: I ADD'ITION: _ode_ L6r CORNER LOT: INSIDE LOT: SETBACK: SIDEYARDS: Applicant attach.to this form Two Certificates of Survey of Lot and proposed building location drawn on these Certificates. To Be Used As: 014; 1 ; e �ts'l ked f - DESCRIPTION OF BUILDING A Front: _ Depth:_ Height: Square Feet: Cubic Feet: �y^ Front: Depth: V^) `j Height: 6a Square Feet: 4;! Cubic Feet: Type of Construction: ® jr�^A To Be Completed: _121 15/72 - �► 0�635� Estimated Cost: $�, Al t. A Alt. B / -- Proposed Driveway Width If New Opening Is Desired 1.4 $ A $ (SEE REVERSE SIDE OF SHEET) (!L-'L� '-�-Y �, '93 The undersigned hereby makes application for a permit for the work herein specified, agreeing to do all work in strict accordance with the City of Fridley Ordinances and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct. See reverse side for additioiaal information. DATE:Q?/?7SIGNATURE: Stipulations: 3, Y __ 604 c.2 3 ,ZVaPL7 oor i j f/® / � 'o ; i QV C70 3 "'5, a do 1-5/8` LUMBER ALLOW. UNIT STRESSES 1-1/2' LUMBER �SANFORD TRUSS S A N F O D 6 0 0 - C PLATES 2X4 TOP 2X4 BTM LUMBER SPECIES 2X4 TOP 2X4 BTM ro m n FB (PSI) FT (PSI) FC (PSI) CHORD CHORD z - C3 CHORD CHORD I ••.%i ID Mf1N CONNtC10. PLATES AN BO GAl14! GALIANDIDSTrU UMISS ISGAUGI6 ID 1114coANDSHALINAPPI "TOMRn'""'c"1M61MIKHlOINI PlA1ESSnyIM 35'-1 ' 32'-3 " N0. 1 K.O. SOUTHERN PINE 1900 1100 1450 34'-10 29'-5 ` o KAlED5,AVAnRKyIIABOUT101NTS VMlSS PIKLMlNIS AM INDIC ATE D$I C'KITS (0) 35•-1 ' 31'-$ ' N0.2 DENSE K.D• SO• PINE_,- 185 . 1050_ 1350 33'-_6 ' 28'-7" k i r NSI tD CUINN.• AND FABRICATION Snyl M KCOMPl151LLU MINI• LOIII• _ - — wHK•.waly!•THAI SNUU J nllht: SO IMS A— PEAll% (Vl RATE SI'Ath AM RAS ED _ 3•IA•MlmyAnwHRIARMUwIDIMANUMAYMINCMAWUR•ASA"KUA•- llttg$Wll• 32'-9 ' 28'-3 ` No. 2 K.D. M.G. so. PINE _ t55o _ 925_ )150 2_9=11" 25'-9 • a H N •wily B-n.CH MA4NUf UISIGN :IANIARUf COWCA 1111 11-1 NAINII+y DISx.N / AI .KA11,,N$ AND IILHI WEAL CONNIVED WOOD MAST$(1WSS PI All IrhlnllTa InID 35'-0 " 30'-3 • N0. 1 DRY SOUTHERN PINE 1750 1000 1250 32'-0 " 27'-7 ' Z a /J� Buc n.GnNos E.0 auoNSlBan.a lnE DlsloNu.Puu wNUlKTum. oe umsrAul CArR PlnovSj,,CIING/ass(sARE CAurIONEDIoslt,MILI IIAy1DvKIWaG.w 27'-0 ' 23'-9 ` N0. 2 DRY SOUTHERN PINE_ 1250 725 850 24'-7 2l'-7 to ~ •J kML I1CN YKn.GA'nKHnywA,S REOUIMD Ip Ptl vlNI hIPPIINL AND DOMINO IND 30'-2 ' 26•_8 • NO. 2 DRY M.G. SO- PINE 14$0 850 1000 27'-6 ` 24•-3 " rl © CLMNG IMCTF'N. AND NWANEN1 RiACINT, w nKn MArMMUU1LLD IN SILCUK APPLKA 1! PtA lRUSUSw4lMfTOC1EDINAF:UANy+DIIRAKMTIOSnWN. MW"AUMIUMRIR 35'-1 " 34'-6 "SEL. STA. DOUG.FIR-LRRCM 2100 1200 1600 3$'-t " 31'-5 i VGE$ ARE SPICDIIO CAMBER SPICIFIL. l5 FSR N1 AAI CUNDnIUNS UI SIWKI AND FABRI N HMA+M IrK"AUDo.a:we:DAn-LAecr"Maslnwe.lLAwesuPIIGN 35'-0 • 31'-0 ' N0. 1 DOUGLAS FIR -LARCH _ 1750 10- 1250 _ 32'-0 ' - " 1 DESIGN L +-• !R, AN PAMK•1 DSUTR+LI6+M5tKn WLLLA5l1 RMOIKIKNynyl BE rM MSPI NU W n♦ OT 1M AKHI/ECI UR FAI.KAT.-R MA.INL SUCH CnAN•.I . lenses SHOIAU M HANDIER ROOF 50 PSF wll cAnDJONGTAM'CAIKN.SH'PPINO.AND IRICIIONIt' .,,ITa_AGT 1.IeA NGE 30'-2 26'-8 NO. 2 DOUGLAS FIR -LARCH 1450 B50 1000 27'-6 24'-3 o AND SIICI{KAIFCMCOMAn4D INTn15 Dk$16N HAVE MIN PRIPARED It, ACCORDANCE wnH 35'_0 29•_5 SELECT STRU• HEMLOCK -FIR 16$0 975 1300 32'-0 ' 26'-10• CEILING SF +ANDAtb ENGINEER—PRACIKES. ANT UAFAAGES Ms R11NLFRM II+c'`RMCI TAE A IW R(S.ONSIBUTY OF THE FABRICATOR. WHT, ASSUMES FELL LUdBIIY TMiMO1. LKENSORMI- 3O' -O ' 26'-1 N0. 1 HEMLOCK -FIR 1400 825 1000 27'-4 " 23'-9 ` TOTAL 60 PSF PRI Sx.DIiCLAW5 AN.RESIONSIBS nr OF LTN411 V POR DISIGNS AND 5PEC6KATgNS FUb, �1 n'ID R,1. FA{MCAI01PWSIIANT 10 FAATY <�A INCOeRCT DATA SUWnTED BY THE FAW . f , 15.0 X UNIT"oR.'u.4tMoa,fARPKAIORna6BIADv1MDOsnSMsvo B4nrFORnSnAW 25'-8 22'-5 N0. 2 HEMLOCK -FIR 1150 67$ 800 23'-4 20'- v J y ZI or n5 CGMINUING NSPONSMaITV TO VERIFY DU*$Nr.S AND SPICIF KAIKIIA Pu=fln. STRESS INCREASE kD91IKEEKENSOBAGAW5ITABRKAIORSOWN PLANS IOMAYICRIAINTHAI THE FURNISHED 35'-1 35'-1 1.8 E MACHINE GRADED 2100 1575 1700 35'-1 3 -t SPEC" KAIFDNSCONTOW TOMPLAN5 ANY DISCR(PANCD53noUl0M WMlDIAI4+RRc+uUH1. " INw.ITWG. To THE LKIN""I'S AND FARRKAIORS ATTENTION MFORL IA.RKATION POB 35'-1 ' 32'-9 '.1.6 E MACHINE GRADED 1800 117$ 1-450 34'-3 ' 29'-10 LiCE"AR•' RIVISIONS ACCVIAME To lDn ENGINEER AND:OR ACHnICI CONCERNED. 33'-1 ' 27'-8 " 1.4 E MACHINE GRADED 1500 900 1200 30'-3 ' 25-2 DESIGN FOR TRUSS 35'- 2" OVERALL SPAN NOTE. NEB MEMBERS TO BE 2X4 NO. 3 OaUdLAf FIR. HEMLOCK. OR SOUTHERN 576• Z PINE. OR 2X3 90.2 OOUDLAS FIR. HEMLOCK. OR SOUTHERN PIKE SPACEC 2'- 0" ON CENTER EXCEPT Re NOTED. s76• _T] RECOMMENDED CAMBER: 1/8" PER 81- 0" OF TRUSS SPAN NOTES FIFTTEEEENUPERCENT INCREASE TAKEN ON FB FOR REPETITIVE E 576• D 4 3 C 403+ CD � TWE ` O ' Oi tri@ YP Jt TYPE S SPLICES IN SAME TRUSS. 2 _ B U C L Tl�+f�xr SPLICES MAY BE USED. I ' 1 P. O BOX 278 -E R A S- ��C s x s P. O. BOX 275 . 27 • X5374 3.5 x 4 230N �-0 c• �{ r� SYMMETRICAL ABOUT S_QQERSj. MN., �53745574 1 2_1/2• EXCEPT AS NOTED aL �4�• I Span 34'- 6' CLEAR SPAN 35'- 2" 5 x 6 TOP CHORD SPLICES R = 2072• 32'- 8" 5 BE 5 IONLT OKE ALLOWED IN ERCM CMORDI B-1 = -5278• 1-2 = -8t0• \ 26'- 8" 5 x 4 pF NEIy C-2 = -43892 2-3 = -578• t?~� M• An Y��j 0-3 a -43896 3-4 = t547• �P......A�O \ F 9a� R -t = sooa• ;E• t'pi:;—T-1 1.5 z 3 v+ o 0-4 = 3051• LIiT[i l :o /LJ t- �P�i, a : raoFtssuaTn • VAPTG. N• F tR �y'rfG 03931 a ;LIA•.F'v�I��v� - �';fillact_s •.. �A `�•��� - �+ v 12 1'ROIES510N* 1f •.6.I ¢4•''Fy lJ —..-1 0 `. �`�� 12 Span Pine/Fir Hemlock 35'- 2" 18-3.5 BE: 4 18-3.5 x 5 34'-0' 3.5 BE 4 3:5 x 5 30'- 8" 3.5 BE 4 3.5 BE 4 SPLICE TYPE B DES10.4 CRITERIA+ 1970 TPI 1.5x4 4 12 - �In Span•• �' 1-1/2" 35'- 2" 3 x 9 I Span 27'-8" 3 x 8 35'- 2" 18-6 x 8 30'-4- 6 x 8 23'- 8" 5'x 8 SPLICE TYPE A Pine/Fir Hemlock 12 35'- 2" 2.5 x 12 35'-2" 3 z 12 34'- B" 2.5 BE 11 33-0" 3x 11 4.00 '8"25 10 30'-0" 3 x 10 27'-0" 3 x 9 024'-0" 3 x 821'-0" 3 x 7Dca "25"- Equal Areas %.TOTE: 2 x 6 Minimum Bearing Required for spans 0 r exceeding: (a) 24'- 8" with Hemlock -Fir N ` N PAGE 15-42 Bl SANFORD TRUSS NOMINAL RANCH BEARINGS. DESIGN STANDARDS CONFORM WITH lIR NATIONAL DESIGN SPCDICATIOM AND LIGHT METAL, CONNECIED WOOD TRAM (TRUSS PLATE 1NSIDUTi). FIELD 1-5/8" LUMBER ALLOW. UNIT STRESSES 1-1/2' LUMBER o S R N F O R D 6 0 0 - C PLATES 2X4 TOP 2X4 BTM LUMBER SPECIES 1250 725 CALWAYS 2X4 TOP 2X4 BTM 0 1450 CHORD CHORD FB FT FCIPSII CHORE) CHORD SANTO RD MEIN CONNECTOR PLATES ARE 2D GAUGE GALVANIZED STEEL UNLESS IB GAUGE IS WECIFIEDANDSHALLEEAPPLIED TOBOTH FACES OFTRUSS AIEACH JOINT .PLATESSHNLRE 27'-2 ' 29'-4 " NO. I K.D. SOUTHERN PINE 1900 1100 .1450 _ 25'-0 26'-B " BL"Y OF THE AICnttCI Ot FNdCAtOt MFJ"TNG SUCH CHANGf. TRUSSES SIOIAD N IUUUDIfD wITnCARE DUtNGFABRKA1gN,SHIPPING, ANNftECTON10PqTVlNtDAMGE.TH[DRAWINGS 22'-1 24'-0 N0. 2 DOUGLAS FIR-LRRCH LOCATED SYMMt1AICNLY NON DIMS UMESS PLACEMENTS ARE INDICATED BY c"Cus EOS OR AS DIM1NSgNED. CUTTING AND IN4ICAIION SMALL 11 COMPLISHED US TNG 1. - 26'-4 ' 28'-6 ' NO.2 DENSE K.O. 80. PINE 1850 1050 1 1350 24'-2 ' 25'-10" =y MINT WHICH WILL PRODUCE SNUGiRING M MINTS AND PLATES. OVERALL SPAARF BASED ONNOMINN1-INCHBLARINGWIDEMSNTDMAYUINCeASEDBYNMLCMA$S-lMlESWRH 23'-8 " 25'-7 ' NO. 2 K.D. M.G. 80. PINE 1550 925 1 1150 21'-9 ' 23'-3 " 1250 23'-2 ' 24'-11' 850 td' -3 ' 19'-3 " 1000 20'-3 " 21'-.10' 1600 26'-6 27'-0 1250 23'-2 ' 25'-1 " 1000 20'-3 ' 21'-10' 1300 23'-1 ' 24'-3 " 1000 20'-1 ' 21'-4 ' Soo 17'-5 " LB' -2 • 1700 27'-0 27'-0 1450 24'-6 ' 27'-0 " 1200 21'-10 22'-B 719EB C 456• 2 1 B 9 R 192• 9' CLtAR SPAN B -I TT -5241• — 1.2 - -8990 C-2= -44990 2-3 12190 R-1 a 5081• 0 d • 33880 SOUTH SIDE UNLIMBER CO. P. Cat BOX 278 nO --tor MN 5$374 R = 1 NOMINAL RANCH BEARINGS. DESIGN STANDARDS CONFORM WITH lIR NATIONAL DESIGN SPCDICATIOM AND LIGHT METAL, CONNECIED WOOD TRAM (TRUSS PLATE 1NSIDUTi). FIELD 25'-3 27'-5 " NO. I DRY SOUTHERN PINE 1750 1000 J 14RACING IS NOT THE RESPONSIBILITY OF IME DESIGNER,PLAIE MANUFACIUfLR. Ot TRUSS FABII- GATOR. PEtSOMELLCTINGIEUSSESARE CAUTIONED TO SEEK PROFESSIONAL ADVICE IN REGARD 20'-0 ' 21'-3 ' NO. 2 DRY SOUTHERN PINE 1250 725 CALWAYS REQUIRED INOING DURING ERECIICHL. AND PLDAANEN1 BRACING WHICH OMAY BE MOV REPREVENT IDAIN SPECIFIC G AND FMAMCA- IOM. TRUSSES SMALL N IRECTED kLitWIN APLUW AND DM, C" POSIION. F SLRVUM LIIMBEt GRADES ARE FOR ANDiAB4- WND01FMKAIO 22'-L 24'-0 ' N0. 2 DRY M.G. 80. PINE 1450 850 (1) 2.5 x 12 29'- 5" 27'- 0" 28'-10' 29'-4 "SEL. STA. DOUG.FIR-LRRCH 2100 1200 DESIGN AT THE AMAL IRA BED.CAMMtS RR1DLDD CATION. DMAYMINC NASETINGFR CLD AT IM AtLnIlkCTS OtFN¢CAORS OPTION. I HOWEVER. ANY, 25'-3 ' 28'-1 ' NO. 1 DOUGLAS FIR-LRRCH 1750 1050 ROOF 50 PSF BL"Y OF THE AICnttCI Ot FNdCAtOt MFJ"TNG SUCH CHANGf. TRUSSES SIOIAD N IUUUDIfD wITnCARE DUtNGFABRKA1gN,SHIPPING, ANNftECTON10PqTVlNtDAMGE.TH[DRAWINGS 22'-1 24'-0 N0. 2 DOUGLAS FIR-LRRCH 1450 850 CEII ING F STANDARDAND E GINNu NGP%4C7KES.CONTAINED IN iMYDAIGN HAVE BEINPREPARED IN ACCORDANKI MAGESRESULTINGFOMINCORRECTUSES�ME 25'-t - 26'-8 - SELECT STRU. HEMLOCK -FIR 1650 975 TOTAL 60 PSF PiiSSLLYYDSLCIALAS YREWO SURFYOF11A"MBRRrfFORDSIGNSIANCSPECVK:TIONsiuw- 21' -ll" 23'-6 ' NO. I HEMLOCK -FIR 1400 625 % UNIT ISHEDB15.0 CAMEYFUUtgMOU,Ff C:10YOIdU6YADVMEOOfttSLLSPONSIDtLIIt OEL115HTPlAM 19'-0 20'-1 N0. 2 HEMLOCK -FIR 1150 67$ STRESS INCREASE AND OF ITS FOR THELICENSOR UAGAINSING TFMRCATOJESOWN PLAMIOSIBILITY TO VERIFY w:RiCERTAINTHAI7HEFIONS Fwwaac 29'-4 " 29'-4 " I.8 E MACHINE GRADED 2100 1575 29'- 5" 3 x 5 N WELDING O THE LICENSORS AND lABRICATO ITS PLANS. TOtTC�LM60N BEpODABELK EAT(ONiw BHT' 26'-B " 29'-4 " 1.6 E MACHINE GRADED 1800 1175 291- 5" 18-5 x 6 18-5 x 8 NECESSARY REVISIONS ACCEPTABLE TO TME ENGINEER AND/OR ARCHITECT CONCERNED. 23'-9 " 25'-0 1.4 E MACHINE GRADED 1500 900 DESIGN FOR TRUSS 29'- S " OVERALL SPAN NOTE, NEB MERBERB TO BE 2X4 NO. 3 OBBBLRe FIR. NEKLOCK. OR BBUTNERN SPLICE TYPE B 7L9* SPACED 2'— O " O N CENTER l NERLBCK. BR BBUTNERN PINE exceeding: (a) 24'- B" with Hemlock -Fir EXCEPT AB NOTED. RECOMMENDED CAMBER: 1/8" PER 8'- 0" OF TRUSS SPAN. NOTE, FIFTEEN PERCENT INCREASE TRKEN am FB FOR REPETITIVE 0 NERBER USE. NOTE: DO NOT COMBINE TYPE A & TYPE B SPLICES IN.SAME TRUSS. 3 IF NECESSARY, TWO TYPE A SPLICES MAY BE USED. 0 1250 23'-2 ' 24'-11' 850 td' -3 ' 19'-3 " 1000 20'-3 " 21'-.10' 1600 26'-6 27'-0 1250 23'-2 ' 25'-1 " 1000 20'-3 ' 21'-10' 1300 23'-1 ' 24'-3 " 1000 20'-1 ' 21'-4 ' Soo 17'-5 " LB' -2 • 1700 27'-0 27'-0 1450 24'-6 ' 27'-0 " 1200 21'-10 22'-B 719EB C 456• 2 1 B 9 R 192• 9' CLtAR SPAN B -I TT -5241• — 1.2 - -8990 C-2= -44990 2-3 12190 R-1 a 5081• 0 d • 33880 SOUTH SIDE UNLIMBER CO. P. Cat BOX 278 nO --tor MN 5$374 R = 1 ± Plate Pine/Fir Hemlock 5x5yR1125'-0" 9G29-5 NEW$pan y 5x4 l0 (1) 2.5 x 13 29'- 0" @R.SYMMETRICAL Otto; (1) 2.5 x 12 29'- 5" 27'- 0" �PR(T$57a ABOUT CL, 26'- 8" 22'- 4" 2-1/2"_ EXCEPT AS NOTED (i) 2.5 x 9 24'- 0" 20'- 0" (1) 2.5 x 8 21'- 0" 18'- 0" 1250 23'-2 ' 24'-11' 850 td' -3 ' 19'-3 " 1000 20'-3 " 21'-.10' 1600 26'-6 27'-0 1250 23'-2 ' 25'-1 " 1000 20'-3 ' 21'-10' 1300 23'-1 ' 24'-3 " 1000 20'-1 ' 21'-4 ' Soo 17'-5 " LB' -2 • 1700 27'-0 27'-0 1450 24'-6 ' 27'-0 " 1200 21'-10 22'-B 719EB C 456• 2 1 B 9 R 192• 9' CLtAR SPAN B -I TT -5241• — 1.2 - -8990 C-2= -44990 2-3 12190 R-1 a 5081• 0 d • 33880 SOUTH SIDE UNLIMBER CO. P. Cat BOX 278 nO --tor MN 5$374 R = 1 DESIGN CRITERIA: 1970 TP1 PAGE 15-33 „ O .� a r � rnrn z� O • O _T O O Cs0 /V C r� V J 0 rn a a r r CA 9 a z CA C= v -4 O N ro v ± Plate Pine/Fir Hemlock 1.5 x 4 (2) 2.5 x 7 29'- 5" y L,2 (1) 2.5 x 13 29'- 0" 3,0 (1) 2.5 x 12 29'- 5" 27'- 0" (1) 2.5 x 11 29'- 0" 24'- 8" 26'- 8" 22'- 4" 2" Q � 9 (i) 2.5 x 9 24'- 0" 20'- 0" (1) 2.5 x 8 21'- 0" 18'- 0" Equal SDoce 12 Span Span 29'- 5" 18-3.5 x 5 29'- 5" 3 x 5 Span Pine/Fir Hemlock Equal Areas 24'- 0" 3.5 x 4 21'- 0" 3 x 4 291- 5" 18-5 x 6 18-5 x 8 251- 8" 18-5 x 5 18-5 x 7 NOTE: 2 x 6 Minimum Bearing Required for spans SPLICE TYPE B 24'- 0" 5 x 5- 5 x 6 exceeding: (a) 24'- B" with Hemlock -Fir SPLICE TYPE A DESIGN CRITERIA: 1970 TP1 PAGE 15-33 „ O .� a r � rnrn z� O • O _T O O Cs0 /V C r� V J 0 rn a a r r CA 9 a z CA C= v -4 O N ro v fl,AA) '0J6. CM OF BUILDING DEPA KTICNT SITMOIK Zjj?=Pr=PAG2 "U" COMPUTATION (To be submitted with buildinS,pormit &pplicaxionl One or two faully dwelling X Owner All other Sit* *� drew Contractor & 0 t LINEAL FT. OF 6� w �o �-4,s e EXPOSED WALL..Q- fto above grad TOTAL, EXPOSED WALL ANZA JW# OPAQUE „WALL CONSTRUCTION: "UP value x:area WAI.tF(�, 1-14 run V72: x sq - ft.(U)(A) *Un x I sq. ft. 74, V 'J"!r7 U) (A Our WHA) Detail reference f M "U" 6'x sq. ft. I from x so (U)(A) attached sheets U sq: ft. (U)(A) —x sq. (U)(A) x sq. U (A run6Now x x sqd. sq ft. 'W�— (U)(A) WINDOWS: "U" �Make type 'value z area x --Sq., ft. M(A) U10 sq.fti (U) sq. (U)(A) nun4i— x sq . WHO run r ''I' sq. (U)(A) run.! ! __ 77x sq. ft* (U) (A),. DOORS: "U" value x � or*&' Make t 0 0-c- -wow-aW'A run 15!r- x sq. ft., If. (U) (A) AL -X 3q 0 rt (U) (A (U) (A sqo f t. U x i sq. ft. — (U) (A) TALS :kz-q,2 4,el I't TOTAL (U) (A) VALUES A'Uor "U' DIVIDED BY TWALE, � LL A REA AVERAGE "Un .19. or less for 1 & 2 rtaily dllings .22 or less for all other buil4ints ROOF/CEILING: TOTAL AREA : 1, o sq. f to .Detail reference run from , "U" s, Sq attached shoots,. Nuo % sq ;Describe openings sq. Irl roof. run x sq, ft. - In (U)(A) ft* HZ� (U) (A) rt U(A ) ) ft. 10010-19, a (U)(A) TOTASq. ft,, 4- , (U) (A) TOTAL (U )'(A ) VA LUES, 4-1.r- 12" !DIVIDED BY TOTAL ROOF/ CEILING AREA wpi, ill ',° W :AVERAGE "U" .0$ for ventilated roof* ,all j'O for LAV;4.4,c-AJ IN AI„W � �, ��� r y, �_:: � {i �. e . t r i h �Py, 'rs: �y, � n � F �T �, `?��jr 9C' y V tN� n, � ,3 ,�gy-� y q '(� }.'Y S 1 �� } r lJ� 1 ny � Pwy�r :...r�rew '..� � r 3 � 3� � .. .. '."� 1t'. J•: �"y' rr y :i;!.. _ 1 0..µ %. F �IRE-�t + 't �yg�a�'� •�ww! .�y" 7�'0�i"_� & � �'µ ,�,.ti`, aft y,,,-�•W �.yD' `�;,,�, .�",�S�h• "� °' 'y,'x�'�'a`, t +,��Y� _ �iy.�� 4�K Y�yAtv.1'�jtY&,.a0"icy�rry �Y�"ihi i^T+ eS ��£ .a `h^ f o+ yy. 7 w, '�Yi�XX,. ! Ili'' �'ljrrrt;:y f �i/"`s ✓� t�}a',. a��-,+. , rJ :;iY s� > "�'» % Ott _ �.�+"�{yk5� AY y>; fr-- 1 r �y��+1. '��� } f�� -� •s�k�{ ��.� t s.A�Y ',;, F s+> � -a r � �' v� f+�'y{�.a� � �, .rr � fi}` s •�� �rq r k� 1?"� �� ,«yy,,,. t �', �� ,.4p }+ �'.t Tfy,��a�•T ��4...r�`gI.'"'i f 'i�{ "'kk cyir � - y {, �i(f' ri^I %�' - . "' "%��,>rP�,a�.r��',�;.. _`"�."�r`"�z�r34t:�`i...�=�:�.�" ,r��:^..,yS,��,"'�} ,:i. �•• .`.�i..:t�'"•W�`�r"s. ' ._ l �x i �IRE-�t + 't �yg�a�'� •�ww! .�y" 7�'0�i"_� & � �'µ ,�,.ti`, aft y,,,-�•W �.yD' `�;,,�, .�",�S�h• "� °' 'y,'x�'�'a`, t +,��Y� _ �iy.�� 4�K Y�yAtv.1'�jtY&,.a0"icy�rry �Y�"ihi i^T+ eS ��£ .a `h^ f o+ yy. 7 w, '�Yi�XX,. ! Ili'' �'ljrrrt;:y f �i/"`s ✓� t�}a',. a��-,+. , rJ :;iY s� > "�'» % Ott _ �.�+"�{yk5� AY y>; fr-- 1 r �y��+1. '��� } f�� -� •s�k�{ ��.� t s.A�Y ',;, F s+> � -a r � �' v� f+�'y{�.a� � �, .rr � fi}` s •�� �rq r k� 1?"� �� ,«yy,,,. t �', �� ,.4p }+ �'.t Tfy,��a�•T ��4...r�`gI.'"'i f 'i�{ "'kk cyir � - y {, �i(f' ri^I %�' - . "' "%��,>rP�,a�.r��',�;.. _`"�."�r`"�z�r34t:�`i...�=�:�.�" ,r��:^..,yS,��,"'�} ,:i. �•• .`.�i..:t�'"•W�`�r"s. ' ._ CITY OF FRIDLEY APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, REFRIGERATION AND ,AIR CONDITIONING SYSTEMS AND DEVICES PARTIAL RATE SCHEDULE GRAVITY WARM AIR: RATE TOTAL Job Address 1-i y- Furnace Shell & Duct Work $12.00 $ Replacement of Furnace 7.00 7.00 $ $ Department of Buildings Repairs & Alterations -up to $500.00 4.00 S City of Fridley Repairs & Alterations each add. $500.00 Tel. #571-3450 MECHANICAL WARM AIR: The undersigned hereby makes application for a permit for the work herein Furnace Shell & Duct Work to 100,000 BTU p1 $12.00 $ 7 .� Z� specified agreeing to do all work in strict accordance with the City Codes each add. 50,000 BTU 4.00 $ and rulings of the Department of Buildings, and hereby declares that all the Replacement of Furnace 7.00 $ facts and representations stated in this application are true and correct. Repairs & Alterations -up to $500.00 7.00 4.00 $ $ Fridley, Minn. Z&O' . 1922 Repairs & Alterations each add. $500.00 STEAM OR HOT WATER SYSTEM: OWNER �Geea &�nf i'� - Boiler & Lines up to 100,000 BTU $12.00 $ KIND OF BUILDING Q�/leip JCe each addn. 50,000 BTU 4.00 $ Boiler only up to 100,000 BTU 7.00 $ USED AS Aop�-� each addn. 50,000 BTU 6.00 $ 0 TO BE COMPLETED ABOUT OIL BURNER- to 3gal. per hour $10.00 $ each add. 3 gal. per hour 10.00 $ ESTIMATED COST GAS BURNER- from 100,000 BTU to 199,999 BTU �9 $10.00 $ OLD -BUILDING PERMIT NO. PERMIT NO. (over 199,999 BTU see Fee Schedule) $ GAS FITTING FEES: 1st 3 Fixtures '� x $ 3.00 $_Q DESCRIPTION OF FURNACE/BURNER Additional Fixtures x $ 1.00 $ Gas Range to 199,000 BTU x $10.00 $dgipor POWER PLANTS, Steam, Hot Wate(, No. AIR CONDITIONING $ Trade Name Size No. d1refA) FAN HEATING SYSTEMS See Fee Schedule $ VENTILATING SYSTEMS $ Capacity Sq. Ft. EDR BTU 0 ObO HP ALTERATIONS & REPAIRS $ State Surcharge $ Total Connected Load JCe1j' S1de Kind of Fuel TOTAL FEE $ �pNj �,/^p,F�.� BURNER - Trade Name , Size No. r��V ROUGH INSP. REINSPECTION FEE Capacity Sq. Ft. EDR BTU �D.V-v� HP Date ($10.00) Company FINAL INSP. .6.',__ Date Signed By_ • APPROVAL FOR PERMIT, Tel. No. X21 -6Z:2 MINIMUM FEE FOR AW HEkTING_ PEB*T U $7.50 PLUS 59 $TAT& SUBCE RgE CITY OF FRIDLEY APPLICATION FOR POWER PLANTS AND HEATING, COOLING, VENTILATION, REFRIGERATION AND 4.00 AIR CONDITIONING SYSTEMS AND DEVICES PARTIAL RATE SCHEDULE 7.00 Repairs & Alterations each add. $500.00 7S�- 59/1 GRAVITY WARM AIR: RATE TOTAL Job Address Furnace Shell & Duct Work $12.00 $ 7.00 Replacement of Furnace 7.00 7.00 $ $ Department of Buildings Repairs & Alterations -up to $500.00 4.00 $ City of Fridley Repairs & Alterations each add. $500.00 Tel. #571-3450 MECHANICAL WARM AIR: Furnace Shell & Duct Work to 100,000 BTU $12.00 each add. 50,000 BTU 4.00 Replacement of Furnace 7.00 Repairs & Alterations -up to $500.00 7.00 Repairs & Alterations each add. $500.00 4.00 SPFAM OR HOT WATER SYSTEM: Boiler &,Lines up to 100,000 BTU $12.00 each addn. 50,000 BTU 4.00 Boiler only up to 100,000 BTU 7.00 each addn. 50,000 BTU 6.00 OIL BURNER- to 3 gal. per hour $10.00 each add. 3 gal. per hour 10.00 GAS BURNER- from 100,000 BTU to 199,999 BTU $10.00 (over 199,999 BTU see Fee Schedule) GAS FITTING FEES: lst 3 Fixtures x $ 3.00 Additional Fixtures x $ 1.00 Gas Range to 199,000 BTU x $10.00 AIR CONDITIONING FAN HEATING SYSTEMS See Fee Schedule VENTILATING SYSTEMS ALTERATIONS $ REPAIRS State Surcharge TOTAL FEE ROUGH INSP. Date FINAL INSP. Date APPROVAL FOR PERMIT S REINSPECTION FEE ($10.00) MINIMUM FEE FOR ANY HEATING PERMIT IS $7.50 PLUS $.50 STATE SURCHARGE The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the City Codes and rulings of the Department of Buildings, and hereby -declares that all the facts and representations stated in this application are true and correct. ,(��//%� Fridley, Minn. `, . 19 �2 OWNER 6yl! nc,2_ ✓L�/�A11 ' % KIND OF BUILDING USED AS TO BE COMPLETED ABOUT ESTIMATED COST OLD - NEW BUILDING PERMIT NO. PERMIT NO. DESCRIPTION OF FURNACE/BURNER HEATING or POWER PLANTS, Steam, Hot Water, Warm Air- No. Trade Name TAkp,!%L Size No. � � GS T ey Capacity/C° Sq. Ft. EDR BTU HP —�— C- Total Connected Load Kind of Fuel Size No. favBURNER - Trade Name Capacity Sq. Ft. EDR BTU HP Company a ®� Signed By Tel. No. • $3,00 Future f acture Opening -X >� $2,00 New Fixture, Old Opening x NJ•U [latch 912 in • .•_� x $5,00 i•Water Hoater - to 99,000 Bill, x $5..00 Hator (� .q+ .+ A •�-•• M a h a e •.01 q N Electric Nater Heater - rl 1� .i p- ('' u, IIQnCOC J •N C N Aj 0 b {q. �yy N .O O i, r� �+ ri A a O w N aj N �x 3 N ns leo r tib o oris ct range -2.md .. ire - IT (_ (R) - Futuro Connection Opening Connected with Suwor (') - 11ow Fizcure, Old Opening Hater PARTIAL RATE.SCHEDULE PLUNLBING FIXTURE RATES; NO, RATE TOTAL Nuz-zer FLxtures $3,00 Future f acture Opening -X >� $2,00 New Fixture, Old Opening x $2,00 [latch 912 in • .•_� x $5,00 i•Water Hoater - to 99,000 Bill, x $5..00 100;C00 'BTU to 199,000 BTU x $10.00 Hater Softaner New Grourd•Run Old Building x $5,00 Electric Nater Heater - X $5,00 CAS FITTING FEES; ' X $3,00 X $1,00 X 110.00 12t 3 fLxtureA 3.Jditicnal rl tures :C11 "Ago to 199,000 BTU REPAIRS d ALTERATIONS rirst 1100.00 each add. $100.00 or fraction State Surcharge TOTAL FEE i $5.00 $ $2.00 $ �~ $ �o $ 10.5p 97-84-416051 ' Job Address 1581 73a Ave. NE Dapartment of Buildings City of Fridley I Tot, 1571-3450 Tito undersigned hereby makes application for parmit for the we aP4Q1fied agrueing•to do all work in strict accordance with the C1 and rulings of Clio Oapartmont of Buildings, and hereby daclaro2 t1 the faots and roprgoentations stated in this application aro true Fridley, M..1, 11-3.0-77 , ONNSR ELMER ISRAELSON KIND OF BUILDING frame USED AS res. TO BE C014PLETED ABOUT 12-7-77' ESTIMATED COST 20.Q0 OLD - NN BUILDIIIG PERMIT NO, P fjMIT 110. . Company ���% K. ,M�NNEGAS Signed By' ECASCO Tol. No. ROUGII INSP. Date FI14kL INSP, Data ' APPROVAL FOR PERMIT MIIIIMUM FEC FOR ANY PLUMBING PERMIT 15 11.50 977 6431 UNIVERSITY AVENUE N.E.. FRIDLEY, MINNESOTA 56432 TELEPHONE ( 612)571-3450 Mr. Elmer Israelson 1581 - 7312 Avenue N. E. Fridley, Mn. 55432 Re: Final Inspection at 1581 - 731� Avenue N.E. Dear Mr. Israelson: A final inspection was made on December 2, 1977 of the above address and the only item not completed was the installation of sod in the front and side yards. We will expect the sod to be installed by June 1, 1978 when a reinspection will be made to determine compliance. If you have any questions on this item, please feel free to contact me at 571-3450. Sincerely, DARREL G. CLARK Community Development Adm. DGC/mh CITY OF FRIDLEY APPLICATION FOR PLUMBING AND GAS FITTING PER41T Job Address , CJ ��� ' s' 'N P Department of Buildings City of Fridley Tel. #571-3450 The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the city Codes and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in thisapplicationare true and correct Fridley, Mn. OWNER I Y �' r, KIND OF BUILDING USED AS TO BE COMPLETED ABOUT PARTIAL RATE SCHEDULE >. M e q ESTIMATED COST u u N0. RATE 0 TOTAL Water of x at $ Future Fixture Opening -.i m O Company w w $2.00 $ Heater _ �14 J X C Catch Basin 3 0 'C�oec o x $5.00 $ Tel. No. 100,000 BTU to 199,000 BTU Is U D w S o w m w u M 3 New Ground Run Old Building U $5.00 a� lec W x $5.00 $ o� TA GAS FITTING FEES: cti c� O as FINAL INSP. 1st 3 fixtures x '$3.00 $ ' Date Additional Fixtures x $1.00 $ Gas Range to 199,000 BTU x $7:0.00 $ APPROVAL FOR PERMIT 1st First $100.00 $5.00 $ each add. $100.00 or fraction $2.00 $ MINIMUM FEE FOR ANY PLUMBING PERMIT IS $7.50 pLUS $.50 STATE SURCHARGE 2nd State Surcharge $ .50 TOTAL FEE REINSPECTION FEE 3rd 4th (R) = Future Connection Opening Connected with Sewer (t) = New Fixture, Old Opening Water Job Address , CJ ��� ' s' 'N P Department of Buildings City of Fridley Tel. #571-3450 The undersigned hereby makes application for a permit for the work herein specified agreeing to do all work in strict accordance with the city Codes and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in thisapplicationare true and correct Fridley, Mn. OWNER I Y �' r, KIND OF BUILDING USED AS TO BE COMPLETED ABOUT PARTIAL RATE SCHEDULE ESTIMATED COST PLUMBING FIXTURE RATES: N0. RATE TOTAL OLD - NEW BUILDING PERMIT NO. _ PERMIT NO. Number Fixtures x $3.00 $ Future Fixture Opening x $2.00 $ Company New Fixture, Old Opening x $2.00 $ Q� _ Signed By i Catch Basin x $5.00 $ Water Heater - to 99,000 BTU x $5.00 $ Tel. No. 100,000 BTU to 199,000 BTU x $10.00 $ Water Softener x $7.00 $ New Ground Run Old Building x $5.00 $ ROUGH INSP. Electric water Heater x $5.00 $ Date ' GAS FITTING FEES: • FINAL INSP. 1st 3 fixtures x '$3.00 $ ' Date Additional Fixtures x $1.00 $ Gas Range to 199,000 BTU x $7:0.00 $ APPROVAL FOR PERMIT REPAIRS & ALTERATIONS First $100.00 $5.00 $ each add. $100.00 or fraction $2.00 $ MINIMUM FEE FOR ANY PLUMBING PERMIT IS $7.50 pLUS $.50 STATE SURCHARGE State Surcharge $ .50 TOTAL FEE REINSPECTION FEE ($10.00) SUBJECT PERMIT N City of Fridley AT THE TOP OF THE TWINS BUILDING PERMIT S � R CEIPT NO. • COMMUNITY DEVELOPMENT DIV. INSPECTION r PROTECTIVE SEC. / NUMBER REV. DATE PAGE OF APPROVED 8V i ` CITY HALL FRIDLEY 55432 .-•.�/"' 812-580-3450 910-F15 4/3/78 JOB ADDRESS 15581 - 7331 Avenue N.E. 1 LEGAL LOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 3 1 Deleier Addition SHEET 2 PROPERTYOWNER MAIL ADDRESS ZIP PHONE Elmer Israelson Jr. 1581 - 7331 Avenue N.E. 784-6991 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Same 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 8 USE OF BUILDING Residential 7 CLASS OF WORK ❑ NEW ❑ ADDITION [j ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE 8 DESCRIBE WORK Finish. hasenent 9 CHANGE OF USE FROM TO STIPULATION S S19FERAT1E PERMITS - REQUIRED► F0 . IR1NG, HEATING, PLUMBING AND: SIGNS. TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SQ. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN 80 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION 1 STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED, $750 $.50. WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIONS FANY OTHER STATE OR LOCAL CON- $7.50 STRUCTION ORTHE PERFORMANCE OF CO STRUC ITONEGULATING PLAN CHECK FEE TOTALFEE $8.00 G URE OFCONTR TORORAU ORIZEDAGE (DATE) ` 3OaAJU WHEN PROPERLY VALIDATED THIS IS YOUR PERMIT ��— 'BLDG INSP DATE SIGNATUREOFOWNER (IF OWNER BUILDER) 1 ATE) CITY OF FRIDLEY APPLICATION FOR RESIDENTIAL BUILDING PERMITS (NEW, ALTERATIONS, ADDITIONS, OR REPAIRS) OWNER: C L.Yyxir �S� c��\5�r� Vii. BUILDER: L M e f �S HCl ��� � ��► Address: 621 l - � S �,� �Q e iV_ E , Address: , �.�, ? � �� ��t 'VE, Tel. No.: 2 7— (mac 7 No.: I Street: A O( LOT: BLOCK: �_ ADDITION: CORNER LOT: INSIDE LOT: SETBACK: 3 j" SIDEYARDS: Applicant attach to this form Wo Certificates of Survey of Lot and proposed building location drawn on these Certificates. DESCRIPTION OF BUILDING To Be Used As: Front: Depth: Height: Square Feet: Cubic Feet: Front: Depth: Height: Square Feet: Cubic Feet: Type of Construction: rcky1 Estimated Cost: $ r To Be Completed: Alt. A Alt. B Proposed Driveway Width If New Opening Is Desired $ $ (SEE REVERSE SIDE OF SHEET) The undersigned hereby makes application for a permit for the work herein specified, agreeing to do all work in strict accordance with the City of Fridley Ordinances and rulings of the Department of Buildings, and hereby declares that all the facts and representations stated in this application are true and correct. See reverse side for additional information. DATE: .-V=2/2? SIGNATURE: Stipulations: 0;7j'3F FRIDLEY INSPECTION DIV. �- 6431 University Ave NE Fridley, MN 55432 572-3604 RATE SCHEDULE Residential APPLICATION FC- ^^"'-^ ^, ".,"' ::E;.�;. " VENTILATION, REFRIGERATION AND AIR CONDITIONING SYSTEMS AND DEVICES Furnace Shell and Duct Work, Burner - Rate Also Replacement Furnace $ 30.00 (Side Vent - Fill Out Back) Gas Piping (Needed with new furnac) $10.00 Gas Range $10.00 Gas Dryer $ 10.00 *Air Conditioning - All Sees $ 25.00 All Others, ,,,,airs & Alterations (LIST ON BACK 1 % of Value of Appliance or Work Commercial/Industrial 1.25% of Value of Appliance or Work - State Surcharge 1� TOTAL FEE Effective On January 1, 1997 JOB ADDRESS The undersigned hereby makes application for a permit for the work herein TOTAL specified agreeing to do all work in strict accordance with the City Codes and rulings of the Building Division, and hereby declares that all the facts and $ representations stated in this application are true and correct. ✓/ ,1997 $/ OWNER Oya4-�c BUILDING USED AS $ ESTIMATED COST PERMIT NO. �. DESCRIPTION OF FURNACE AND OR BURNER $ No. of Heatin Units Circle One (Steam) (Hot Water) (Warm Air) Trade Name k Size No. BTU!!�a HP EDR $ Fuel Total Connected Load $ .50 Burner Trade 1 vai � a Size No. MINIMUM FEE FOR ANY HEATING/COOLING/VENTILATION REFRIGERATION/AIR CONDITIONING PERMIT IS $25.00 PLUS THE $.50 STATE SURCHARGE REINSPECTION FEE $42.00/Hr *Air Conditioners can not be placed in a side yard without written permission from adjoining property owner. BTU HP EDR HEATING COMP Signed 0 Tel No..,( 0� Approved By- ligh-In na+n FILL OUT BACK SIDE F R STACK VERIFICATION ON REPLACEMENT FURNA E Final Date ,34 Remarks:. r, I List ALTERATIONS BeinDone• HEATING CO: Signed By: Date: CRENINEY AND STACK VERIFICATION The undersigned hereby verifies that the existing chimney or stack: 1. Has been careftilly examined Yes () No ( ) 2. Is free from rust or deterioration Ye: () No ( ) 3. Has no foreign objects lodged within Yes () No ( ) 4. Is securely supported Yes () No ( ) 5. Meets all current Code requirements for size and total BTU's connectp t Y,:s O No C ) 6 Has total heating BTU's o F All other BTU's TOTAL BTU's 7. Has a liner been provided for water heater Yes () No ( ) 8. Has combustion air been provided for water heater Yes( No ( ) Remarks:. r, I List ALTERATIONS BeinDone• HEATING CO: Signed By: Date: SUBJECT P , City of Fridley 2 6 9 8 9 AT THE TOP OF THE TWINS BUILDING PERMIT r ECEIPT NO. _____ COMMUNITY DEVELOPMENT DIV. �,: - PROTECTIVE INSPECTION SEC. 4119 r 1 � NUMBER REV DATE PAGE OF APPROVED BY i CITY HALL FRIDLEY 55432 612-571-3450 910-F15 8/5/98 JOB ADDRESS 1581 73 1/2 Ave 1 LEGALLOT NO. BLOCK TRACT OR ADDITION SEE ATTACHED DESCR. 3 1 1 Deleir Addition SHEET 2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE Harold Holmstrom 786-7258 3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO. Royal Construction 28222 96 St Zimmerman 444-0458 20050156 4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO. 5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO. 6 USE OF BUILDING Residential 7 CLASS OF WORK ❑ NEW ❑ ADDITION ❑ ALTERATION XX REPAIR ❑ MOVE ❑ REMOVE B DESCRIBE WORK Reroof house and garage (24 Sq) Tear-off; Construct deck 6'x24' 8'x10` 224 s.f. 9 CHANGE OF USE FROM TO STIPULATIONS Underlayment must comply with State Building Code. WARNING Before digging call for a all utility locations 454.0002 REQUIRED BY LAYS SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, TYPE OF CONST. OCCUPANCY GROUP OCCUPANCY LOAD VENTILATING OR AIR CONDITIONING. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION ZONING SO. FT. CU. FT. AUTHORIZED IS NOT COMMENCED WITHIN BO DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COMMENCED. NO. DWLG. UNITS OFFSTREET PARKING I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION STALLS GARAGES AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS VALUATION SURTAX AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT $4010 $2.00 DOES NOT RESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PERMIT FEE SAC CHARGE PROVISIO OF ANY OTHER STATE 09 LOCAL LAW REGULATING CON- STRUCT OR THE E CE CONSTRUCTION. $99.75 Fire SC $4.01 �i� PLAN CHECK FEE TOTAL FEE License W $5.0 1 410.76 IGNATURE OF CONTRACTOR OR AUTHO AGENT IDATEI NRO r �NSp VALIDATE THIS IS Y L PER f)ATE SIGNATURE OF OWNER OF OWNER BUILDER) IDATEI NEW [ ] Effective 1/1/98 ADDN [ ] CITY OF FRIDLEY ALTER [ ] SINGLE FAMILY AND DUPLEXES R-1 AND R-2 BUILDING PERMIT APPLICATION ConstructionAddress: i5-01 %3 k� Ave, Legal Description: 11 Owner Name & Address: P CA Ra i- b �n j m sm6yy Tel. # % �,(4.. ?a.S� Contractor: RQ VC,, l CoNS7levc7-?&U MN LICENSE Address: 6a 202 A671-1.51 NAJ 3S3 9 r Tel. # y1/y-0YJY Attach to this application, a Certificate of Survey of the lot, with the proposed construction drawn on it to scale. DESCRIPTION OF IlAPROVEMENT LIVING AREA: Length Width Height Sq. Ft. GARAGE AREA: Length Width Height Sq. Ft. �/ DECK AREA: Le S %1 "N.2,YY' Width 9 1f X /0" � r Hgt/Ground � 5q. Ft. OTHER:.�C31�6-Y,� Construction Type. K Estimated Cost: $ (Fee Schedule on Back) Driveway Curb Cut Width Needed: Ft. + 6 Ft = Ft x $ _ $ DATE: �— /-/-�� APPLICANT: Tel. # CITY USE ONLY Permit Fee $ Fee Schedule on Reverse Side Fire Surcharge $ q-01 .001 of Permit Valuation (1/10th%) State Surcharge $ 2 .00 $.50/$1,000 Valuation SAC Charge $ $1000 per SAC Unit License Surcharge $ 5: o v $5.00 (State Licensed Residential Contractors) Driveway Escrow $ Alt. "A" or Alt. "B" Above Erosion Control $ $450.00 Conservation Plan Review Park Fee $ Fee Determined by Engineering Sewer Main Charge $ Agreement Necessary [ ] Not Necessary [ ] TOTAL $ 0-76 . STIPULATIONS: a r • f ^ L --. -.- ,r- o* ��..-- ,- w ---------e __. _..... .,PWi1WcW p7 q,,y � . +wI;al+�ay� rse.• a+m..- _ � � •.�; 1-14 �' Ci .. .l'i> `•'0`. `N vY:�i-. e'..i1.d-J .: S:.J i:i...._. i rac4lwgeacalaaa .•,1� ,/� .. � tt.-, r. tv-� rte-.. .. ..re•..•e... ...•re.cndi':.:.- •r Cortificato of Survoy for 4tQ !o.2-5 1 —72.25_ O � 6i 1 6 Lo- - ---- - - --moi 1 72.25— - - - — -' `� . �.... �• ...,....1. tit+a: i h � s.a Y.• lyre 54,x; NORTH' 0 73 4 VEA VE o Denotes ,ron' rnonumenf -- - - - - - -- Oenoles Orwno, e F L07 3 SLOCKiii .1 ,r . F�xsemen}�' 02"ELVER 401017=10'aft/AV A NOrIA COUNTY do:t heresy terr.fy that th,sto a rove and ia.rert represenfa/len of a survey o1 rhe boundaries of rhe above ,"10ed •tend, and of the larar,on of *Il butld,n� /o rho.een end all visible ensreorhmsintsr if any, from a ave sold 'lend As swt-oyrd by me this day at -1._'>(l_t_r SU®l l��I �fV1mIh0EEE:lfd(3, INC. In'�we s S%er�yars e Depot #2802, 5650 MAIN ST., N.E., FRIDLEY, 14N 55432; 14 18:17:05 1!:')98 saved as: c:\cqd,esign\decks\4440458b.DEK Dimensions fc:c Deck 1 A Vi 16' 31 P-) U • k CITY OF FRIDLEY INSPECTION DIV. 6431 University Ave NE Fridley, MN 55432 (763) 572-3604, FAX (763) 571-1287 MARK NUMBER OF FIXTURES TO BE INSTALLED ON EACH FLOOR 05 — 0 0 8 �q Effective April 1, 2004 APPLICATION FOR PLUMBING AND GAS FITTING PERMIT Stories IIilUrinal Floor 1 Floor 2 Floor 3 Floor 4 PLUMBING FIXTURE RATES: Wash > FloorIS Auto. 1 i Wash er Y � NO. RATE TOTAL JOB ADDR r2Z Heater New Fixtures $10.00 The undersigned hereby makes application for a permit for the work herein Old Opening, New Fixture $10.00 specified agreeing to do all work in strict accordance with the city codes Beer Dispenser $10.00 and rulings of the Building Division, and hereby declares that all the facts Blow Off Basin $10.00 and representations stated in this application are true and correct. Catch Basin $10.00 Rain Water Leader $10.00 E: , 20C' Sump/Receiving Tank Water Treating Appliance $10.00 $35.00 ZZ OWNER DeeS�S Water Heater -Electric $35.00 Water Heater - Gas"" $35.00 BUILDING AS �e S[4?1� Gas Range" $10.00 4tfw Gas Dryer** $10.00 ESTIMATED COST PERMIT NO. Back Flow Preventer Required ( )Yes () No Type $15.00 PLUMBING COMPANY uh &1� Reinspection Fee $50.00/Hr SIGNED BY TEL N0. M ALL OTHERS AND/OR REPAIRS AND ALTERATIONS 1.25% of Value of Fixture or Appliance Approved By Rough -In Date Final Date State Surcharge $ .50 MINIMUM FEE F ANY PLUMBING/GAS PERMIT IS $16.00 or 5% OF COST TOTAL FEE OF THE IMPRO ENT WHICHEVER IS GREATER ON WORK LESS THAN 300 1-1 COMBUSTION AIR SHALL BE PROVIDED PER UMC SECTION 504(A) AND TABLE 6-A. "*PROVIDE COMMON VENT INFO ON BACK SIDE t FILL IN COMPLETELY FOR REPLACEMENT FUEL BURNING APPLIANCE PERMITS COMMON VENT VENT CONNECTOR AND COMBUSTION AIR VERIFICATION When replacing an existing furnace, the undersigned hereby verifies that the venting has been examined and is free from rust, deterioration, obstructions, and is securely supported and firestopped where required. Yes () No( ) The venting system is plastic/PVC and meets all current codes and manufacturer specifications including sizing, length, number of elbows and terminatidn. Yes () No( ) The undersigned also verifies that the replacement unit is a listed asseinbly and meets the current codes and manufacturer's specifications. This does include AGA-GAMA Category I Central Furnace Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) Tfie existing combustion air is sized and installed to meet the current codes and manufacturers specifications. Yes () No( ) When required to install a new combustion air, it will be sized and installed to meet the current codes and manufacturer's specifications. Yes () No ( ) When installing a new venting system, the undersigned hereby verifies that it is a listed assembly and meets the current codes and manufacturer's; specifications. This does include AGA-GAMA Category I Central Fumice Venting Tables for fan assisted and natural draft appliances. Yes () No ( ) Is the common vent and vent connectors sized and installed correctly after an appliance has been removed from the common vent and vented separately as per current codes. Yes () No( ) Appliance Type and Size/Common Vent and Vent Connector Information Appliance #1 Type _ Appliance #2 Type _ Appliance #3 Type _ Total Appliances _ BTU Input _ BTU Input _ BTU Input Total Btu Input Common Vent Type Vent Height Fan Assisted or Nat Fan Assisted or Nat Fan Assisted or Nat Diameter inches Appliance #1 Vent Connector Height ft Length ft Diameter. in Type Appliance #2 Vent Connector Height ft Length ft Diameter in Type Appliance #3 Vent Connector Height ft Length ft Diameter in Type ALTERATIONS: (Describe) HEATING CO: Signed By: Date :