PRE 2010 DOCS0 Date:
City of Fridley, Minn.
BUILDING PERMIT
March 31, 1967
,37
N9 91
Ed- Ray Builders
Owner: � Builder Es1-.. Ram Bui1dera_..._�..._..
Address 1391 76th Ave. N. E. Address 7651 Central Ave. N. E.
LOCATION OF BUILDING
No. 1391 _ Street ___ 76th Ave. N. E. Part of Lot
Lot — 22 ..._.___ Block 3 Addition or Subrt n . Meadowmoor Terrace
Corner Lot .__X _ Inside Lot --. _ Setback � 3 —_ Sideyard __ 20 ft
Sewer Elevation evation _____� _.._ Foundation Elevation _ 889.16
Top of Footing Elevation
DESCRIPTION OF BUILDING
To be Used as:
Dwelling Front 40 ' Depth 24' Height 20' Sq. Ft. ____ 960 Cu. Ft. 19,2 0
Front Depth . Height . _ Sq. Ft. _ _ Cu. Ft.
Type of Construction Frame Est.$ 11, 000.00 _ _ To be Completed May 15, 1967
• Sewer Location- 53 ' E. of Manhole
Water Location 10; E. of Sewer
•
In consideration of the issuance to me of a permit to construct the building described above, I agree to do
the proposed work in accordance with the description above stt� and in ance with all provisions of
ordinances of the city of Fridley. / A /_ f/
tt t►"_-,�
� 1'=
In consideration of the payment of a fee of $ 20.00 , permit is hereby granted to. Ray Swenson
to construct the building or addition as described above. This permit is granted upon
the express condition that the person to whom it is granted and his agents, employees and workmen, in all work
done in, around and upon said building, or any part thereof, shall conform in all respects to the ordinances of
Fridley, Minnesota regarding location, construction, alteration, maintenance, repair and moving of buildings
within the city limits and this permit may be revoked at any time upon violation of any of the provisions of said
ordinances.
Clarence Belisle
NOTICE:
This permlt does not cover the condrucdon, histallatlon for whbq, phmnbing, gas heating, sewer or water. Be sure to see
the Building Inspector for separate permits for these hems.
� . s
APPLICATION FOR BUILDING PERMIT
CITY OF FRIDLEY, MINi11ESOTA
OWNER' S NAME 'k
ADDRESS�AAe- / ADDRESS
LOCATION OF BUILDING
NO.. All —3 STREET 7 Ce /,r " e a PART OF LOT
LOT` 2 L_BLOCK �3 ADDITION OR SUBDIVISION
CORNER LOT INSIDE LOT SETBACK , fl�' IDE -YARD 10
SEWER ELEVATION S�5 6./ � FOUNDATION ELEVATION 90
Applicant attach to this form Two Certificates of Survey of Lot and proposed
4qb�uilding location drawn on,these Certificates.
c z Cr,77ei, ASCRIPTION OF BUILDING
To Be Used": '
Front p I Depth C Height -
s
Sq. Ft.Cu. Ft. PJ
Front Depth Height
Sq. Ft. Cu. Ft.
Type of Construction_ Estimated Cost./ i� a�
To Be Completed
The undersigned hereby makes application for a permit for the work herein specified,
agreeing to do all work in strict accordance with the City of Fridley Ordinances
and rulings of the Department of Buildings, and hereby declares that all the facts
and representations stated in this application are true and correct.
DATE
0—
(Schedule of Fee Costs can be found on the Reverse Side).
Application for Power Plants and Heating. Cooling. Ventilation. Refrigeration and
Air Conditioning Systems and Devices
PARTIAL RATE SCHEDULE
GRAVITY WARM AIR: RATE TOTAL
Furnace Shell & Duct Work ........................... 8.00 $
Replacement of Furnace ............................. 5.00 $
Repairs & Alterations—up to $500.00 .................. 5.00 $
Repairs & Alterations each add. $500.00 ............... 2.50 $
MECH. WARM AIR
Furnace Shell & Duct Work to 120,000 BTU ............ 8.00 $ tl�
each add. 60,000 BTU ....................... 2.00 $
Replacement of Furnace ............................. 5.00 $
Repairs & Alterations—up to $500.00 ................. 5.00 $
Repairs & Alterations each add. $500.00 .............. 2.50 $
STEAM or HOT WATER SYSTEM
Furnace Shell & Lines—to 400 sq. ft. EDR Steam ..... 8.00 $
Furnace Shell & Line—to 640 sq. ft. EDR Hot Water .. 8.00 $
Each add. 200 sq. ft. EDR Steam ...................... 2.50 $
Each add. 320 sq. ft. EDR Hot Water .................. 2.50 $
OIL BURNER—to 3 gal. per hour 5.00 $
over 3 gal. per hour—See Fee Schedule
GAS BURNER (up to 400,000 BTU) ....................... 5.00 $ ✓
GAS FITTING FEES: NO RATE TOTAL
1st 3 Fixtures ..................... x $1.50 $
Additional Fixtures ................. x .50 $
Gas Range to 200,000 BTU ........... x 2.00 $
AIR CONDITIONING $
FAN HEATING SYSTEM See Fee Schedule
VENTILATING SYSTEM
ALTERATIONS & REPAIRS TOTAL FEE $
ROUGH
FINAL
Dept. of Bldgs. Phone 560-3450 /�
Location %_q f / — �lo � X � -.
City of Fridley:
The undersigned hereby makes application for a permit for the work herein
specified, agreeing to do all work in strict accordance with the City Ordinances
and ruling of the Department of Buildings, and hereby declares that all the facts
and representations stated in this application are true and correct.
idley, Minn 2 19
Owner
Kind of Building
'A A Y/ .
Used as
To be completed about
Estimated Cost, $ T4 01
Old New. uilding Permit No.131
Permit No. �9
DESCRIPTION OF WORK
HEATING or PO R team36 Hot Warm _Wum
No
Trade Name � � -P �,� c'/%Y 1 Size No 46160
/�
D
Capacity Sq. Ft EM.R o BTU � H.p.
Total Connected Load Kind of Fuel 4 TA, -J
BURNER —Trade Name Size No
Capacity Sq. Ft. E.D.R BTU H.P.
NAY N.WELTER HEATING C131
S O AVE.
y
42 Business Phone No-
(REMARKS—OVER) R .
V V
P IT NO.
City of Fridley
12suBJEcr
952
AT THE TOP OF THE TWINS
BUILDING PERMIT
r
R
�
r • ___COMMUNITY DEVELOPMENT DIV.U.
INSPECTION
PROTECTIVE SEC.
IL /�--1 CITY HALL FRIDLEY 55432
NUMBER
REV.
DATE
PAGE OF
APPROVED BY
---- . ,-J 612-560-3450
910-F15
5/20/75
JOB ADDRESS 1391 - 76th Avenue N.E.
1 LEGAL
LOT NO.
BLOCK
TRACT OR ADDITION SEE ATTACHED
DESCR.
22
3
Meadowmoor Terrace SHEET
2 PROPERTYOWNER MAIL ADDRESS ZIP PHONE
Larry Steeves 1391 - 76th Avenue N.E.
3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO.
Same
4 ARCHITECT OR DESIGNER MAIL ADDRESS, ZIP PHONE LICENSE NO.
5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO.
6 USE OF BUILDING
Residential
7 CLASS OF WORK
JV NEW ❑ ADDITION ❑ ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE
8 DESCRIBE WORK
Construct a.22' x 24' Iii Garage
9 CHANGE OF USE FROM TO
STIPULATIONS provide a hard surface driveway.
SEPERATE PERMITS REQVIRED FOR WIRING,
HEATING, PLUMBING AND SIGNS.
TYPE OF CONST.
OCCUPANCY GROUP
OCCUPANCY LOAD
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
VENTILATING OR AIR CONDITIONING.
Wood Frame
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
ZONING
SQ. FT.
CU. FT.
AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION
OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT
R-1
528
5280
ANY TIME AFTER WORK IS COMMENCED.
NO. DWLG. UNITS
OFFSTREET PARKING
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
1
STALLS GARAGES
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
VALUATION
SURTAX
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT
$3,907.20
1.95
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PERMIT FEE
SAC CHARGE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON-
STRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
$10.00
PLAN CHECK FEE
TOTALFEE
$11.95
IGNATURE OF CO 11RACTOR OR AUTHORIZED AGENT (DATE)
P�ROgPERLY VALIDATED THIS IS YOUR
WHEN PROPERLY
7
�PERMIT
.g(-/IiJC/I�JL WJ � )4
BLDG INSP D E
SI NF NERIIF OWNER BUILDERI (DATE)
ATURE W
V V
M
9-115 % rA � IF' I J118
irk
4,4s.314E P?
720.�J- kk)7!-Ln
0o QooM
�c� ►13�`t Sid"�
1
I, _TC) t4IJ T)UC,e-U kf,, ESC /L) , owner of the property located
at have no objection to the City
allowing the construction of a C.hf 0 lrAU GE to be located at
/3 71 X'4,4 t Iva without the required certificate of
survey that the City ordinarily requires for all new construction.
/4 �� 1,��
Sign
Address
Date
6W t" �Iw�xrpu/
AIA
l /
4iff
vwph7?,
NG1NEER!NaJV INC. Am"'
Sawt 4066
Fn1nee rs Sur veyon5 ---
f
CePICIli ca to of s , my iro$ Jumewsw AM L�/fs
a 0Tee16
V-
IS.
e
�-- b
�a
Im
oDZMOTL 1R9N — -- _' DINVTE9 11T/L/TY 4 DRAINACaZ' .EASEMENT
/OT..�...B�. c ____. 3AZADDWrYooR TERRA c
COUAITY Of' ANOWA
! hereby cerfil y Mvo Ibis es a fnm and mfnd rePresw Fiona of o swwey a6e+r oi�riybdd land, ao�d
a�1,t�zc /ncofi.>n c�'o!J b�tdmgs . ffxiPan , &V ot! risible enunvrltrsurf: , r�'m, y, �rwri or ao said laid. As swveyed y iw �-- °by
A.D. I Y <V 3 UR8AN ENGINEERING , INC.
F.n�( rrreers Fr Styr s .
APPLICATION FOR RESIDENTIAL, ALTERATION,
OR ADDITION BUILDING PERMIT
CITY OF FRIDLEY, MINNESOTA
6y
��r
OWNER'S NAME • BUILDER :e �t4I 1
ADDRESS: -/37/ &��_&XADDRESS:
NO:. 1,391 STREET:
LOT:�� BLOCK: 3 ADDITION: / p IG�Af�� M DoL —rE&gC.E
CORNER LOT: INSIDE LOT: SETBACK: SIDEYARD:
Applicant attach to this form Two Certificates of Survey of Lot and proposed
building location drawn on these Certificates.
DESCRIPTION OF BUILDING
To Be Used As:
r %r
Front: Depth: �/ Height:
Square Feet: Cubic Feet:-�
Front: Depth: Height:
Square Feet; Cubic Feet:
Type of Construction: �.'�C-A Estimated Cost:
To Be Completed: it 3900. r2®
The undersigned hereby makes application for a permit for the work herein
specified, agreeing to do all work in strict accordance with the City of
Fridley Ordinances and rulings of the Department of Buildings, and hereby
declares that all the facts and representations stated in this application
are true and correct.
DATE:
SIGNATURE:
(See Reverse Side For Additional Information.)
�0 ��
i��q
IF
City of Fridley
SUBJECT
2 5 5 6
AT THE TOP OF THE TWINS
?
BUILDING PERMIT
f
R NO.
: COMMUNITY DEVELOPMENT DIV.
`y ------
PROTECTIVE INSPECTION SEC.
r i
7
i =
CITY HALL FRIDLEY 55432
NUMBER
REV
DATE
PAGE OF
APPROVED BY
612-571-3450
910-F15
3/19/98
JOB ADDRESS 1391 76 AVENUE NE
1 LEGAL
LOT NO.
BLOCK
TRACT OR ADDITION SEE ATTACHED
DESCR.
22
3
Meadowmoor Terrace SHEET
2 PROPERTY OWNER MAIL ADDRESS ZIP PHONE
Tom Bruins 1391 76 Avenue NE 571-3878
3 CONTRACTOR MAIL ADDRESS ZIP PHONE LICENSE NO.
Panelcraft of MN 3118 Snelling Ave, Mpls., MN 55406 721-6628 2179
4 ARCHITECT OR DESIGNER MAIL ADDRESS ZIP PHONE LICENSE NO.
5 ENGINEER MAIL ADDRESS ZIP PHONE LICENSE NO.
6 USE OF BUILDING
Residential
7 CLASS OF WORK
❑ NEW ❑ ADDITION ❑ ALTERATION J7 REPAIR ❑ MOVE ❑ REMOVE
8 DESCRIBE WORK
Reroof; Soffit & Fascia; Reside; Replacement windows
9 CHANGE OF USE FROM TO
STIPULATIONS
Underlayment must comply with the State Building Code. Install
building wrap and have inspection of same unless manufacturers specifications
state it is not required. Provide smoke detectors to comply with the State
Building Code - on each level of dwelling adjacent to sleeping areas and in
each sleeping room.
SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING,
TYPE OF CONST,
OCCUPANCY GROUP
OCCUPANCY LOAD
VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION
ZONING
SO. FT.
CU. FT.
AUTHORIZED IS NOT COMMENCED WITHIN 60 DAYS, OR IF CONSTRUCTION
OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT
ANY TIME AFTER WORK IS COMMENCED.
NO. DWLG. UNITS
OFFSTREET PARKING
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION
] ISTALLS
GARAGES
AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS
VALUATION
SURTAX
AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
WITH WHETHER SPECIFIED HEREIN OR NOT. THE GRANTING OF A PERMIT
$14,000
$7.00
DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE
PERMIT FEE
SAC CHARGE
PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CON-
SC $14.00
STRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
$212.25
Fire
PLAN CHECK FEE
TOTALFEE
License SC $5.00
$238.25
SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT IDATEI
WHEN PROPERLY ALIDATED THIS ISV URPPE,RRMITTy!�
��
B4 INSP GATE
SIGNATURE OF OWNER, IF OWNER BUILDER] IDATEI
I Litec;tive Iii/94
ADDN (I CITY OF FRIDLEY
ALTER �A SINGLE FAMILY AND DUPLEXES R-1 AND R-2
Building Permit Application 1�1
r
Construction Address: ���, 7041\
Legal Description:
Owner Name & Address: �� ���� Tel. #
Contractor: k.W.Q CMN LICENSE// _ —
. Address:_; Sn�'(�, �����t� Tel. # 7cA `C&2a( S.�
Attach to this application, a Certificate of Survey of the
lot, with the proposed construction drawn on it to scale.
DESCRIPTION OF IMPROVEMENT
LIVING AREA: Length Width Height Sq. Ft.
GARAGE AREA: Length Width Height Sq. Ft.-
DECK
t.DECK AREA: Length Width Hgt/Ground Sy. Ft.
OTHER:
Corner Lot Inside Lot Ft. Yd Setback Side Yard Setbacks
Type of Construction: �' ` Estimated Cost: $
Approx. Completion Date: 1�40errnrA U -61's - t4� Stv- \ ek�c�v�eS
( Cost on Back)
Driveway Curl) Cul Width Needed: F G Ft = I-' - _ $ p.
DATE: 2 Z -I APPLICANT; Tel. # -7 21 - (PZ -
am
Permit Fee
$��Z5
Fire Surcharge
$ .co
State Surcharge
$_ Z. (D
SAC Charge
$ —
License Surcharge
$ 5-00
Driveway Escrow
$
Erosion Control
$
Park Fee
$
Sewer Main Charge $
TOTAL $ 253.25
STIPULATIONS:
CITY USE ONLY
Fee Schedule on Reverse Side
.001 of Permit Valuation (1/10th%)
$.50/$1,000 Valuation
$800 per SAC Unit
$5.00 (State Licensed Residential Contractors)
Alt. "A" or Alt. "B" Above
$450.00 Conservation Plan Review
Fee Determined by Engineering
Agreement Necessary I I Not Necessary I I
�s�a6e-
3 A 9
11�16L/ s6Z lycz
r I L"11. %.,ILY Us ra fumy IU I QW—IJULAJ f—cqv— JWj VOL06 WNW.- -.-I —
Building
MECHANICAL
Permit NO-: —
Inspections
RESIDENTIAL APPLICATION
Received By: W
763-572-3604
CITY OF FRIDLEY
Date Rec'd:
I)AW OL-2i�=-L- YOU�E.MAZ ADDRESS ---_---_
SITEADDRMJ:__
THIS APPLICANT LS' C3 OWNM Q5&NTRACTOR
PR TY NAME: 2,��C 2)) -2
OVINEW ADDRM: 1� L Q. f)V( ylP, crry STATf
TMANT
PHONE:
CONTRACTOR
COWAWN=
SUBMIT A COPY OF
CONTACT P
YOUR STATE
LAICPPENCSETAITOMN
STATE LICENSHfi UP DATE
k
ADDRESS: -'IN(IA
PHONE-9.- i FAX
0 SINGLE FAWLY 0TWO FAMLY 13 TQWNHO1=-
PERMIT TYPE
TYPE OF WORK.
M NEW bil"LACKMENT E3 ALTERATIO14REMODEL
DETAILED DESCRIPTION OF WORK I C�f�bj Ej A A na
PERMS 165665 the permit fee is amininpumef $15.00orS% of the total cost up to $00-00, Whichever ISAWW. for rhe
improvement, installation or replacement of a residential fixture, excluding the fixtures. (This should reflect only the cod of labor)
Labor cost under $300 - $15.00. Labor cost between $300 to $500 - cost of labor x.05
FORPROJEcTS WHERE LABORExcEEDs, s5omm ARF BASED oNS10.00 MR FDaUM., EXCEPT WNW NOTED. FOMME& (INDICATE TOTAL
NUMER, OF EACH BELOW)
rqdpmcm MmEcd mr.G. L_80A��
MFC. MODEL.
hWa MODEL: SIZEMTU
—AIC US -00 (GAS) $15.00 GAS RANOWOVEN $10.00
—ACES35.0G
—FIREPLACE
_AIR TO AIR EXCHANOM 315 LACE (WOOD) $35.00 _Mw OAS GPJLL $I 0_09
—130a.n
335.00 n=—GAS UNIT RM $10-00
_BOILER
LDMR 510.60 _GAS
GASD&M$I&0Q —POOL HEATER 235-00
DUCT WORK $10.00 _0AS PIPING 510.00 VEI-MLATORSIS.00
Aim
W00
Permit Fee S
Number of fixtures $ 10.00 x $10.00 - $
Surcharge $_
Number of fixtures (it $15.00 x 315.00 = S
TOTAL DUE $
Number of fixtures @ $23.00 x $25.00 = C _
Number of fixtures (a) $35.00 x $35.00 = $
State Surcharge - $ .5
Total - S
THIS is ZQ "MCATION FOR A PERMIT -NOT VALID UNTIL PROCMED
I hereby apply for a buildirig permit and t acknowledge that the information above is complete and accurwv, that the work will be is
conformance, witli the ordinances and codes of the City of Fridley and with the Kumcsots Construction Coclea, that I understand this is
not a permit but only an application for a permit and work is not to start without a permit; that the work wiH be in acoonimm with the
plan in.
approved plan the case of &�fork which Im re . aw and approval of Plans,
-27
SIGNATURE OFAPPLICANT &,4 00 PRINT NAME DATE_q -
5.
City of Fridley
Ouilding Inspections Department
6431 University Avenue NK Fridley, MN 55432
763-572-3604
FAX: 763-502-4977
Building
BUILDING
Permit No ` l
Inspections
RESIDENTIAL APPLICATION
Received By:R! -
763-572-3604
CITY OF FRIDLEY
DWAc40V- 70U
DATE `
YOUR E-MAIL ADDRESS + h ru , n 5 i h A M
a 1 I a e D✓YI
SITE ADDRESS 1 ? I
THIS APPLICANT IS:
OWNER ❑CONTRACTOR
PROPERTY OWNER/
NAME: a S
ADDRESS: 13� 17 (D P•� - CITY
STATF�/�ZIP
TENANT
PHONE: '7&-3 - -N 744q q� -o
CONTRACTOR
NAME:
STATE LICENSE # EXP DATE
SUBMIT A COPY OF
YOUR STATE LICENSE
ADDRESS: CITY
STATE—ZIP—
TATEZIPWITH
WITHAPPLICATION
PHONE FAX
PROPERTY TYPE
Z SINGLE FAMILY/NEW CONSTRUCTION SIZE Je/ X 410
❑ TWO FAMILY/NEW CONSTRUCTION STORIES I
PERMIT TYPE
❑ ADDITION ❑ GARAGE/SHED ❑ WINDOWS
BASEMENT FINISH ❑ROOF ❑DRAIN TILE
❑ DECK ❑ SIDING ❑ OTHER
❑ SWIMMING POOL
TYPE OF WORK:
❑ NEW ❑ ADDITION
❑ MADJTENANCEIREPAIR REMODELING
/
DESCRIBE WORK BEING DONE:c�-;, /�n�Sh��►o, 11 i� w ll� a � Pr rouv�
t� r—% reSS (wlvlcEoco
SIZE OF IMPROVEMENT LENGTH WIDTH HEIGHT S . Ft.
ROOFING
❑ HOUSE ONLY
NUMBER OF SQUARES
❑ HOUSE & GARAGE
BASEMENT REMODELING SUBMIT:
GARAGES
❑ ATTACHED GARAGE
1. Existing Floor Plan
2. Proposed floor plan
PROPOSED SIZE:
❑ DETACHED GARAGE
3. List of structural members to be used
PROPOSED HEIGHT:
SIDING
FOR NEW CONSTRUCTION INCLUDING DECKS,
❑ Vinyl
❑Soffit
ADDITIONS. & PORCHES SUBMIT:
❑ Aluminum
❑ Trim
1. Site Plan/Survey showing the existing structures
❑ Other
❑ Fascia
and proposed project
2. Two'sets of construction plans
WINDOWS
IN STING OPENINGS )4Yes ❑No LOCATION OF WINDOWS 1JC �i�
EXISTING
3. Energy Calculations
OR FOR NEW OPENINGS-DESCRIBE SIZE OF
OPENING CHANGES &
TYPE OF WINDOW TO BE INSTALLED -e NUMBER OF WINDOWS
ALL FEES ARE BASED ON VALUATION, INCLUDING THE COST OF LABOR AND MATERIALS:
(USING THE 1997 U.B.0 FEE SCHEDULE)
TOTAL JOB VALUATION S '3. �')c) c) OCCUPANCY TYPE
Permit Fee $
Plan Review $
Surcharge
License Surcharge
SAC Charge
Curb Cut Escrow
Erosion Control
Park Fee
Sewer Main Charge
Total Due
See Back Page for Fee Schedule
65% of Building Permit Fee
.0005 x Permit Valuation Minimum $.50
$5.00 (State Licensed Residential Contractors)
$1675 per SAC Unit (Plans to MWCC for determination)
ft+6ft= 8x$21=$
$450 Conservation Plan Review
Fee Determined by Engineering
Agreement necessary ( ) Non Necessary ( )
Make checks payable to: City of Fridley Attach
THIS IS AN APPLICATION FOR A PERMIT -NOT VALID UNTIL PROCESSED
I hereby apply for a building permit and I acknowledge that the information above is complete and accurate; that the work will be in
conformance with the ordinances and codes of the City of Fridley and with.the Minnesota Construction Codes; that I understand this is not a
permit but only an application for a permit and work is not to start without a permit; that the work will be in accordance with the approved
plan in the case of all work whi quires rev 'w'�j approval of plans.
SIGNATURE OF APPLIC v' PRINT NAME J®/ %4QS �'Gs r h S DATE
C
I
%3493
I
The 2007 Minnesota State Building Code adopts the 2006 International Emergency escape and rescue openings shall be operational from the
Residential Code (2006 IRC). All "R" code references provided in this inside of the room without the use of keys, tools or special knowledge
brochure pertain to the 2006 IRC. (R319.1.4).
Emergency escape and rescue openings
Basements and every sleeping room shall have at least one operable
emergency and rescue opening. Such opening shall open directly Into
a public street, public alley, yard or court. Where basements contain
one or more sleeping rooms, emergency egress and rescue openings
shall be required in each sleeping room, but shall not be required
In adjoining areas of the basement. Where emergency escape and
rescue openings are provided, they shall have a sill height of not
more than 44 inches (1118 mm) above the floor. When a door opening
having a threshold below the adjacent ground elevation serves as an
emergency escape and rescue opening and is provided with a bulkhead
enclosure, the bulkhead enclosure shall comply with R310.3. The net
clear opening dimensions required by this section shall be obtained
by the normal operation of the emergency escap4and
rescue opening from the inside. Emergency escaperescue openings with a finished sill height below adjacent ground elevation shall be provided
with a window well in accordance with
Inotm
R310.2. Emergency escape and rescue 4.openings shall open directly into a public 44 hwh"way, or to a yard or court that opens to a
public way (R310.1).
Exception: Basements used only to house mechanical equipment and
not exceeding total floor area of 200 square feet (18.58 m2).
All emergency escape and rescue openings shall have a minimum net
clear opening of 5.7 square feet (0.530 m2) (R310.1).
Exception: Grade floor openings shall have
a minimum net clear opening of 5 square
feet (0.465 m2).
A window with an opening that meets the
minimumwidthandheightwillnotnecessadly *\
meet the minimum required open area. The
minimum net dear opening height shall be
24 inches (610 mm) (R310.1.2).
The minimum net dear opening width shall A
be 20 inches (508 mm) (R310.1.3).
Openable 24"
Right: An illustration of an emergency escape area
and rescue window meeting the minimum G feet
a.e
requirements [20 x 41.04" / 144" = 5.7 square ,minimum`.
feet minimum net openable area ].
The minimum horizontal area of the window well shall be 9 square feet
(0.9 m2), with a minimum horizontal projection and width of 36 inches
(914 mm). The area of the window well shall allow the emergency
escape and rescue opening to be fully opened (R310.2).
Exception: The ladder or steps required by R310.2.1 shall be permitted
to encroach a maximum of 6 inches (152 mm) into the required
dimensions of the window well.
Window wells with a vertical depth greater than 44 inches (1118 mm)
shall be equipped with a permanently affixed ladder or steps usable
with the window in a fully open position. Ladders or steps required
by this section shall not be required to comply with sections R311.5
and R311.6. Ladders or rungs shall have an inside width of at least 12
inches (305 mm) on center vertically for the full height of the window
well (R310.2.1).
Bulkhead enclosures shall provide direct access to the basement. The
bulkhead enclosure with the door panels in the fully open position shall
provide the minimum net dear opening required by R310.1.1. Bulkhead
enclosures shall also comply with R311.5.8.2 (R310.3).
Bars, grilles, covers, screens or similar devices are permitted to be
placed over emergency escape and rescue openings, bulkhead
enclosures or window wells that serve such openings, provided the
minimum net clear opening size
complies with sections R310.1.1 to
R310.1.3, and such devices shall
be releasable or removable from
the inside without the use of a key,
tool, special knowledge or force
greater than that which is required
for normal operation of the escape
and rescue opening (R310.4).
Emergency escape windows are
allowed to be installed under decks
and porches provided the location
of the deck allows the emergency
escape window to be fully opened
and provides a path not less than
36 inches (914 mm) in height to a
yard or court (R310.5).
r�
Replacement windows Installed in buildings meeting the scope of the
International Residential Code shall be exempt from the requirements of
Sections R310.1, R310.1.1, R310.1.2, and R310.1.3 if the replacement
window meets the following conditions:
1. The replacement window is the manufacturer's largest standard size
window that will fit within the existing window frame or existing rough
opening. The replacement window shall be permitted to be the same
operating style as the existing window or a style that provides for a
greater window opening area than the existing window.
2. The rooms or areas are not used for any Minnesota state licensed
purpose requiring an egress window; and
3. The window is not required to be replaced pursuant to a locally
adopted rental housing, or rental licensing code (R310.1.5).
A special note regarding guards around windows
The Minnesota State Building Code does not specify requirements
for guards around window wells to keep persons from falling into
them, falls can and do occur. Because of the variations in the size,
location and depth of window wells and since a guard could present
an impediment to escape or rescue, the code is silent The potential
for falls into a window well should be evaluated by the homeowner and
suitable guards or visual barriers provided based on the location, depth
and size of the well. Barriers, guards or covers installed to prevent falls
must be placed In such a way that does not impede use of the window
well for escape and rescue. If covers are used, the effects of snow
on the ability to open or remove them in an emergency must also be
evaluated.
The ever-increasing concern for security, particularly in residential
buildings has created a fairly large demand for security devices such
as grilles, bars and steel shutters. Unless properly designed and
constructed, these security devices over emergency windows can
completely defeat the purpose of the emergency escape and rescue
window. The code makes provisions for use of security devices,
provided the release mechanism has been approved by the building
official and it is operable from the inside without the use of a key or
special knowledge.
Fire deaths have been attributed to the inability of the individual
to escape from the building because the security bars prevented
emergency escape. Security devices should only be installed where
absolutely necessary and only with a permit after an evaluation by your
local building and fire official.
Thousands of fires occur in residences
each year. Many of these fires occur at
night when the occupants are asleep.
Severe Injuries or death can be the result
of these fires If the occupants are asleep
and unaware the fire Is in progress. Death
usually results from asphyxiation long
before the fire reaches the occupants.
In order to prevent the loss of life, the
Minnesota State Building Code requires
smoke alarms to be installed in dwellings
to alert the occupants of a fire.
The code also has emergency escape and
rescue opening requirements for sleeping
rooms. Dwelling units are required to have
windows or doors that may be used for
emergency escape or rescue including
basements. Where basements contain
one or more sleeping rooms, emergency
egress and rescue openings shall be
required in each sleeping room, but shall
not be required in adjoining areas of the
basement.
The size of windows and doors, required in
the code are based on extensive research to
determine the proper relationships of height
and width of window openings to adequately
serve for both rescue and escape.
Emergency escape and rescue openings
shall open directly into a public way, or to a
yard or court that opens to a public way, so
the occupants may escape or be 'rescued
directly from the room to the outside without
having to travel through the building itself.
When a fire occurs, fime is critical to survival.
There may not be enough time to instruct
family members and guests about the proper
window operation or to perform complex
operations to get the window open. The
code requires windows and doors used for
emergency escape or rescue to be readily
openable without any special knowledge or
effort. This means that no window sashes
may be tilted or removed to obtain the
required open area, width or height. Local
building officials can be consulted to assist in
the evaluation of special types of windows.
When a fire occurs, time is critical to survival. So, the Minnesota State
Building Code features emergency escape opening requirements. Sleeping
rooms require windows and doors that can be readily opened without any
special knowledge or effort. Rescuers need public access to a bufliding
and space to enter quickly, possibly wearing extra gear. Everyone should
know what a smoke alarm sounds like and practice how to safely escape.
An emergency escape plan should include a test of the smoke alarm and
a safe place to meet such as a mailbox or sidewalk.
ca