2021-02133 ROOFING
Sfwjfxfe
up!3131!NO!Cvjmejoh!Dpef
2102403132
Ejhjubmmz!tjhofe!cz!Tufwf!Uipsq
EO;!D>VT-!F>tufwfo/uipsqAgsjemfzno/hpw-!
P>Djuz!pg!Gsjemfz-!PV>Cvjmejoh!Efqbsunfou-!
Tufwf!Uipsq
DO>Tufwf!Uipsq
Ebuf;!3132/19/34!24;48;61.16(11(
Code Approval Guide
October, 2016
Table of Contents
Introduction......................................................................................................................................................
iii
Guidelines........................................................................................................................................................
iv
Sure-Tough Mechanically Fastened Roofing Systems:
UL Approvals:
5
Non-Combustible - ANSI UL - Class A.............................................................................................................
6
Combustible - ANSI UL - Class A.....................................................................................................................
7
Combustible - ANSI UL - Class B.....................................................................................................................
8
Combustible and Non-Combustible - ANSI UL - Class C.................................................................................
8
Existing UL Rating to Remain - Combustible and Non-Combustible................................................................
FM Approvals:
9
FM Ratings with Mechanically Fastened Membrane - Plates............................................................................
10
FM Ratings with Mechanically Fastened Membrane - Bars..............................................................................
11
FM Fire Ratings with Mechanically Fastened Membranes................................................................................
12
1-120 Wind Uplift Equivalency Ratings............................................................................................................
13
ANSI-SPRI 4474 Approvals with Mechanically Fastened Membrane - Plates..................................................
14
ANSI-SPRI 4474 Approvals with Mechanically Fastened Membrane - Bars...................................................
Sure-Tough Metal Retrofit Roofing Systems:
15
Metal Retrofit.....................................................................................................................................................
Sure-Seal Design "B" Loose Laid Ballasted Roofing Systems:
16
UL Approvals ...................................................................................................................................................
16
FM Criteria.......................................................................................................................................................
Sure-Seal Design "C" Loose Laid Protected Roofing Systems:
17
UL Approvals....................................................................................................................................................
Sure-Seal FR Nonreinforced, Sure-Tough, Sure-Tough FR and Sure-White Adhered Roofing Systems:
UL Approvals:
18
Non-Combustible - ANSI UL - Class A.............................................................................................................
19
Combustible - ANSI UL - Class A.....................................................................................................................
21
Combustible - ANSI UL - Class B.....................................................................................................................
22
Combustible and Non-Combustible - ANSI UL - Class C.................................................................................
22
Existing UL Rating to Remain - Combustible ...................................................................................................
ź
Table of Contents
FM Approvals:
23
SecurShield HD New Construction....................................................................................................................
25
SecurShield HD Recover...................................................................................................................................
26
SecurShield HD Plus New Construction............................................................................................................
28
SecurShield HD Plus Recover...........................................................................................................................
29
Polyiso HP-H New Construction.......................................................................................................................
31
Polyiso HP-H Recover.......................................................................................................................................
32
SecurShield and SecurShield HD Composite New Construction.......................................................................
34
SecurShield Recover..........................................................................................................................................
35
Securock New Construction...............................................................................................................................
37
Securock Recover..............................................................................................................................................
38
DensDeck Prime New Construction...................................................................................................................
41
DensDeck Prime Recover..................................................................................................................................
42
HP Recovery Board New Construction.............................................................................................................
44
HP Recovery Board Recover.............................................................................................................................
45
OSB New Construction......................................................................................................................................
46
OSB Recover.....................................................................................................................................................
47
Lightweight........................................................................................................................................................
48
1-165 Wind Uplift Equivalency Ratings (over OSB).........................................................................................
National, State & City Building Code Approvals............................................................................................
49
State of Florida Evaluation Report...................................................................................................................
49
Reference Notes...............................................................................................................................................
50
źź
600526 - EPDM Codes 10/2016
CARLISLE SynTec
A Division of Carlisle Construction Materials, Incorporated
CODE APPROVAL GUIDE
October, 2016
INTRODUCTION
This Code Approval Guide addresses both general information pertaining to Underwriters Laboratories (UL) and FM Approvals test criteria
Fastened EPDM Roofing Systems. Various independent test laboratory results along with national building code approvals are also
identified in this guide. Code approvals available with Carlisle's FleeceBACKHot Mopped, Sure-Flex and Sure-Weld Roofing
Systems are identified in separately published Code Approval Guides.
Code ratings are categorized by roof system type (Adhered, Ballasted, Mechanically-Fastened) and are separated into 2 sections; UL
Approvals and FM Approvals. Underwriters Laboratories rated roof assemblies are grouped according to deck type (non-combustible or
combustible) and are further categorized by the severity of fire exposure (Class A, B or C). FM Approval assemblies are categorized
according to deck type and the specific type of construction (new, tear-off or retrofit). These ratings can also be found at the FM Approvals
web site using RoofNAV (free subscription) at http://roofnav.fmglobal.com/roofnav/login.aspx.
The listed assemblies contained in this guide are grouped generically based on deck classification. Specific substrate requirements for each
Carlisle Roofing System can be identified in the respective Carlisle Specifications.
In the UL and FM Approvals throughout this guide, when multiple layers of insulation are referenced, the product listed first identifies the
insulation directly below the membrane. For example; a listing of HP Recovery Board/Polyisocyanurate indicates the HP Recovery Board is
installed directly under the membrane. A listing of Gypsum Board/Polystyrene indicates the Gypsum Board is installed directly under the
membrane.
The Table of Contents on the previous pages identifies the sections contained in this publication.
<< TABLE OF CONTENTS
źźź
600526 - EPDM Codes 10/2016
General Guidelines for
Underwriters Laboratories and FM Approvals
Code Compliance
These guidelines are intended to focus on the essential criteria to be followed when an Underwriters Laboratories (UL) and/or FM Approvals (FM) approved assembly
is specified. Generally, the Carlisle published specifications reflect the minimum requirements necessary to obtain the applicable Carlisle warranty. Code
requirements are not specifically covered in the Carlisle specifications and are considered to be above and beyond the provisions of the Carlisle warranty.
Individuals specifying an approved assembly or selecting various products to achieve a specific UL/FM rating must recognize the importance of ensuring proper
component selection to fully comply with the most current listings published. All materials used in the roofing system must be UL and/or FM approved and
must have been tested together as part of a complete roofing assembly.
In addition to the code approval listings in this guide, information pertaining to approved assemblies can also be referenced in the following directories:
1. Underwriters Laboratories On-Line Certifications Directory (ul.com)
2. FM Approvals RoofNav website (roofnav.com). FM RoofNav assembly numbers can be obtained from this website.
Underwriters Laboratories, FM Approvals and ANSI/SPRI WD-1 Clarifications/Enhancements
UNDERWRITERS LABORATORIES:
1. The criteria required to obtain UL external fire ratings (Class A, B or C) can be identified in this guide or can be searched for on the UL website using
the UL category code TGFU. UL ratings approved for use on combustible decks are also acceptable on non-combustible decks.
2. For UL internal fire ratings (hourly constructions - P Numbers), search the UL website using the UL category code BXUV.
FM APPROVALS:
Uplift ratings listed in this guide are for the field of the roof. Additional requirements/enhancements are required by FM in the perimeter and corner areas,
for deck securement and for perimeter nailer/edge attachment. Refer to FM Property Loss Prevention Data Sheets 1-28, 1-29 and 1-49 for specific
requirements. On FM insured projects, the local FM insuring agent MUST review and approve the proposed roofing assembly prior to installation. When
FM is not the insuring entity for the building, use the Approved American National Standard ANSI/SPRI WD-1 for design purposes.
Note: All Carlisle Roof Systems referenced within this document meet Class 1 construction and Severe Hail (SH) ratings.
APPROVED AMERICAN NATIONAL STANDARD ANSI/SPRI WD-1:
The ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies should be referenced when a project is not FM insured. This document was
developed as a consensus National Standard and provides a methodology for designing for wind uplift resistances of roofing system assemblies. Insulation
fastening patterns are included in this document. The fastening patterns are approved for use by Carlisle.
RECOVER
Recover approvals in this document are based on the following existing roofing system assumption - the existing Smooth Asphalt BUR, Modified Bitumen or single-
ply system was FM approved at the time of installation.
SUMMARY
Due to complexity of the code documents and the variety of information that must be reviewed, it is important to consult with Carlisle and other respective
manufacturers concerning the most current available approvals.
Prior to project bid - Products specified by the architect must be thoroughly investigated to determine if the specified rating can be achieved and local
building codes must be consulted regarding any additional requirements.
Prior to installation - Project managers should review the code requirements with field construction personnel to ensure compliance with project
requirements.
Upon completion of the roofing installation, each project is inspected by a Carlisle Technical Representative to ensure compliance with Carlisle's current
specification requirements for the issuance of the applicable warranty. However, this inspection is not for the purpose of verifying code compliance.
<< TABLE OF CONTENTS
źǝ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Sure-Tough Mechanically-Fastened Roofing System
Non-Combustible - ANSI/UL 790 Spread of Flame Test (Class A)
Membrane
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane
Type:
Non-Combustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick)
Maximum Slope
System IDDeck TypeInsulationCover Board
Sure-ToughSure-Tough FR
HP-H, SecurShield, SecurShield HD, SecurShield
1HD Plus or SecurShield HD Composite- any N/A1/2"3/4"
combination, any thickness
Any UL Classified EPS or XPS Insulation, any
2SecurShield HD Plus or SecurShield HD 1"2"
thickness
Composite
SecurShield HD Composite over any UL
3N/A1/2"3/4"
Classified EPS or XPS Insulation, maximum 1.25
pcf, any thickness
Insulfoam SP or Insulfoam SP over Insulfoam
4N/A1/2"1/2"
EPS, any thickness and density
Insulfoam HD Composite or Insulfoam HD
5Composite over Insulfoam EPS, any thickness and N/A1"2"
density.
Non-Combustible
Any UL Classified Insulation, any thickness
63"4"
(OPTIONAL)Fiber Board
Any UL Classified Insulation, any thickness
73"4"
(OPTIONAL)Board
Any UL Classified Insulation, any thickness
83"4"
(OPTIONAL)Prime Roof Boards
Any UL Classified Insulation, any thickness
91"2-1/2"
(OPTIONAL)
Any UL Classified Insulation, any thickness
101"2-1/2"
(OPTIONAL)
Any UL Classified Insulation, any combination,
11Carlisle FR Base Sheet1/2"3/4"
any thickness
Cellular Lightweight
12N/AN/A1"2-1/2"
Concrete
Precast concrete with
13N/AN/A1"2-1/2"
grouted joints
Structural (poured-in-
14N/AN/A1"2-1/2"
place) concrete
<< TABLE OF CONTENTS
tğŭĻ Ў ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Sure-Tough Mechanically-Fastened Roofing System
Combustible - ANSI/UL 790 Spread of Flame Test - Class A
Membrane
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane
Type:
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in.
(minimum) thick
plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Maximum Slope
System IDThermal Barrier/Base SheetInsulationCover Board (2)
Sure-ToughSure-Tough FR
Combustible - ANSI/UL 790 Spread of Flame Test-Class A
Any UL Classified Carlisle Polyisocyanurate Insulation, any
1N/A1/2"3/4"
Fiber or Glass Mat Roof Boards (1) combination, any thickness.
Any UL Classified Carlisle Polyisocyanurate Insulation, any
2N/A1/2"3/4"
Prime Roof Boards (1)combination, any thickness.
3N/AN/A1/2"1/2"
HD Composite. (1)(3)
4N/AN/A1/2"1/2"
5Carlisle FR Base SheetN/A1/2"1/2"
(1)(4)
6N/A1/2"1/2"
Insulation, any combination. (1)SecurShield HD Plus
7Carlisle FR Base Sheet1/2"1/2"
Insulation, any combination. (1) SecurShield HD Plus
8N/A (1)(5)N/A1/2"1/2"
9N/A1/2"1/2"
SecurShield HD Plus
10N/AN/A1/2"1/2"
any UL Classified EPS Insulation. (1)(6)
11N/AN/A1/2"1/2"
12N/AN/A1/2"1/2"
Any UL Classified Carlisle Polyisocyanurate Insulation, any
13N/A3"3"
combination, any thickness.Gypsum Fiber Roof Board (1)
14N/AAny UL Classified Insulation, any thickness (OPTIONAL)2"2"
Gypsum Fiber Roof Board (1)
15N/AAny UL Classified Insulation, any thickness (OPTIONAL)3"4"
Gypsum Fiber Roof Board (1)
16One Ply of Type G2Any UL Classified Insulation, any thickness (OPTIONAL)3"4"
Glass Mat Roof Board (1)
17N/AAny UL Classified Insulation, any thickness (OPTIONAL)DensDeck/DensDeck Prime Roof 3"4"
Boards (1)
Three or Two layers of Carlisle FR Base Any UL Classified Carlisle Polyisocyanurate Insulation, any
18N/A1/2"1/2"
Sheetcombination, any thickness.
<< TABLE OF CONTENTS
tğŭĻ Џ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Sure-Tough Mechanically-Fastened Roofing System
Combustible - ANSI/UL 790 Spread of Flame Test - Class B
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane
Membrane Type:
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in.
(minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Maximum Slope
Thermal Barrier/Base
System IDInsulationCover Board
Sheet
Sure-ToughSure-Tough FR
Combustible - ANSI/UL 790 Spread of Flame Test-Class B
1N/AN/A1/2"1/2"
HD Composite. (7)(8)
2N/A1/2"1/2"
Polyisocyanurate Insulation. (7)SecurShield HD Plus
3N/A (7)(9)N/A1/2"1/2"
Any UL Classified Carlisle Polyisocyanurate
One Layer of Carlisle FR
4Insulation, any combination, any thickness N/A1/2"1/2"
Base Sheet
(OPTIONAL)
5Inverted G3 cap sheetN/AN/A1/2"1/2"
<< TABLE OF CONTENTS
tğŭĻ А ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Sure-Tough Mechanically-Fastened Roofing System
Combustible and Non-Combustible - ANSI/UL 790 Spread of Flame Test (Class C)
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane
Membrane Type:
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in.
(minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Non-Combustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick)
Maximum Slope
Thermal Barrier/Base
System IDInsulationCover Board
Sheet
Sure-ToughSure-Tough FR
Combustible - ANSI/UL 790 Spread of Flame Test-Class C
2" layer of any UL Classified Carlisle
1N/AN/AUnlimitedUnlimited
Polyisocranurate Isulation
Non-Combustible - ANSI/UL 790 Spread of Flame Test-Class C
Any layer of UL Classified Carlisle
1N/AN/AUnlimitedUnlimited
Polyisocyanurate Insulation.
Existing UL Rating Retained
Non-Combustible and Combustible
(Directly over existing Class A, B or C)
Maximum Slope
System IDDeck TypeExisting SubstrateInsulation
Sure-ToughSure-Tough FR
Carlisle FR Base Sheet IS over existing
min. UL Class "C" rated Type III or IV
1N/ASmooth Asphalt BUR, Mineral Cap Sheet, Slip Sheet1/2"1/2"
Modified Bitumen or approved single-ply
to remain
Existing min. UL Class "C" rated Type III
or IV Smooth Asphalt BUR, Mineral Cap
2N/ANone1/2"1/2"
Sheet, Modified Bitumen or approved
single-ply to remain
Carlisle FR Base Sheet IS over existing
minimum Class C rated adhered or
3N/ASlip Sheet1/2"1/2"
mechanically fastened single-ply systems
(excluding PVC)
<< TABLE OF CONTENTS
tğŭĻ Б ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Sure-Tough Mechanically Fastened Roofing System with Plates
Membrane Type:
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane (12)
(10)
Min. 22-gauge Grade E Steel or Structural
Min. 22-gauge Grade C Steel
Concrete (11)
Membrane WidthFastener/PlateSpacing
Sure-Tough Sure-Tough FRSure-Tough Sure-Tough FR
1-90
1-901-901-90
(350373-0-0)
splitting sheet
1-601-601-601-60
1-105
1-1051-1051-105
(350372-0-0)
1-601-601-601-60
1-901-901-901-90
1-90
1-901-901-90
Polymer Seam Plate(381749-0-0)
1-751-1051-105
1-75
(350375-0-0)(179770-0-0)(179094-0-0)
1-60160
--
(182024-0-0)(182017-0-0)
1-901-90
1-751-75
Polymer Seam Plate
(222334-0-0)(222332-0-0)
1-901-90
--
(5460-0-0)(5146-0-0)
1-901-90
--
Polymer Seam Plate
(222334-0-0)(222332-0-0)
(RoofNAV numbers) for steel decks
<< TABLE OF CONTENTS
tğŭĻ В ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Sure-Tough Mechanically Fastened Roofing System with Bars
Membrane Type:
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane
(16)
FM Uplift Rating (16)
Max.
FM ApprovedField SheetCarlisle HP-X Fastener With Polymer Batten or Metal
Fastener
Grade E
Deck TypeWidthFastening Bars
Spacing
Steel DecksSteel (Min.22-gauge) Decks
(13)(15) or Structural Concrete(14)(15)
1-90
10'6" o.c. -Polymer Batten
(144041-0-0)
1-1201-75
HP-X Fasteners (steel
8'6" o.c.Polymer Batten
(181911-0-0)(333566-0-0)
decks); CD-10 or HD
Steel (15) or Structural
Concrete1-60 1-60 14-10 (Concrete
Polymer Batten
Decks)
(181530-0-0)(181530-0-0)
1-90
1-90Metal Fastening Bar
(350374-0-0)
(RoofNAV Number)
<< TABLE OF CONTENTS
tğŭĻ ЊЉ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Fire Ratings
Sure-Tough Mechanically Fastened Roofing Systems
.045", .060" or .075" Sure-Tough or Sure-Tough FR EPDM Membrane
Membrane Type:
Maximum Slope for
Deck Type Insulation Insulation Thickness
Sure-ToughSure-Tough FR
HP Recovery Board, SecurShield HD or
SecurShield HD Plus over FM approved 1/2" Min.
Insulation
New Construction/Tearoff:
Steel (Min. 22-gauge)
HP Recovery Board (min. 1/2"), SecurShield HD,
1"3-1/2"
Structural Concrete
or SecurShield HD Plus or (min. 1/4") DensDeck
Wood (18)
Prime or Securock over: FM approved Insulation
Refer to FM RoofNav website
Tectum
(17)
Retrofit (No Tearoff) (19)
Structural Concrete
Polyisocyanurate HP-H1-1/2"-12"
Maximum Slope for
Deck Type Insulation Insulation Thickness
Sure-ToughSure-Tough FR
HP Recovery Board, SecurShield HD or
Retrofit (No Tearoff) (19):
1/2"-1"1"3-1/2"
SecurShield HD Plus
Steel (Min. 22 guage)
Wood (18)
Tectum
Polyisocyanurate HP-H 1" Max.
<< TABLE OF CONTENTS
tğŭĻ ЊЊ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Sure-Tough Mechanically-Fastened Roofing Systems
1-120 (120 psf) Wind Uplift Equivalency Ratings*
Membrane Requirements:
Maximum 7 foot wide Sure-Tough .060" thick EPDM membrane with Carlisle HP Fasteners and 2" diameter Polymer Seam Plates spaced
6" on center. *
120 psf Uplift Resistance* (1-120 Approval Equivalency on 12' X 24' Table) (20)
InsulationMinimum ThicknessInsulation Fastening Density
Any approved insulation Minimum Approved Thickness (21)1 per 8 square feet
Fasteners/Polymer Plates.
<< TABLE OFCONTENTS
tğŭĻ ЊЋ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Sure-Tough Mechanically-Fastened Roofing System
ANSI-SPRI 4474 Approvals With Plates
Sure Tough .045", .060" or .075"
Membrane Type:
Sure-Tough FR .045", .060" or .075"
(22)
Field SheetMax. FastenerRequired
Approved Deck TypeCarlisle FastenerUplift
WidthSpacingFastening Plates
HP Fasteners (wood);
Seam Fastening Plates
Wood or Structural Concrete
CD-10 or HD 14-10 (concrete)
1-90
HP Fasteners (wood);
Grade E Steel or Structural
Polymer
Concrete
CD-10 or HD 14-10 (concrete)
HP Fasteners (steel/wood);
Steel (min. 22-gauge), Wood or
10'6" o.c.Polymer1-90
Structural Concrete
CD-10 or HD 14-10 (concrete)
HP Fasteners (steel);
Grade E Steel or Structural
10'6" o.c.Polymer1-105
Concrete
CD-10 or HD 14-10 (concrete)
Steel (min. 22-gauge)PolymerHP Fastener1-105
HP Fasteners (steel/wood);
Steel (min. 22-gauge) or Structural
Polymer1-105
Concrete
CD-10 or HD 14-10 (concrete)
6" o.c.HP Fasteners (steel);1-120
Grade E Steel or Structural
10' Polymer
Concrete
CD-10 or HD 14-10 (concrete)1-60
HP-Xtra Fastener1-75
Steel (min. 22-gauge)
Grade E SteelHP-Xtra Fastener1-90
<< TABLE OF CONTENTS
tğŭĻ ЊЌ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Sure-Tough Mechanically-Fastened Roofing System
ANSI-SPRI 4474 Approvals With Bars
Sure Tough .045", .060" or .075"
Sure-Tough FR .045", .060" or .075"
Membrane Type:
(23)
Uplift Rating
Carlisle HP-X Fastener With
ApprovedField SheetMax. Fastener
Grade E
Polymer Batten or Metal Fastening
Deck TypeWidthSpacing
Steel Decks or Steel (Min.22-gauge)
Bars
Structural ConcreteDecks
10'6" o.c.1-901-90
HP-X Fasteners (steel decks); CD-10
Steel or Structural Concrete
8'6" o.c.1-1201-120
or HD 14-10 (Concrete Decks)
1-601-60
<< TABLE OF CONTENTS
tğŭĻ ЊЍ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
SURE-SEAL METAL RETROFIT
ROOFING SYSTEM
UNDERWRITERS LABORATORIES (UL) APPROVALS
The UL ratings achieved with the Metal Retrofit Roofing System are identical to the approvals listed for the Sure-Tough
Mechanically-Fastened Roofing System over non-combustible decks depending on the membrane selected (Standard Reinforced or
FR Reinforced EPDM). Click here for ratings.
FM APPROVALS
As referenced in FM Approvals Loss Prevention Data Sheet 1-31, the method of recovering an existing metal roof system with a
single-ply mechanically fastened roofing system where the membrane is secured through the existing metal roof directly to the
structural purlins is recognized as an appropriate recovery system when installed per the recommendations of FM.
FM Approvals has accepted the securement of Carlisle's reinforced EPDM membrane with RUSS (Reinforced Universal Securement
Strip) as an alternate to "in-seam fastening" as used in our Sure-Tough Mechanically-Fastened Roofing System. As such, the wind
uplift resistance of the Sure-Seal Metal Retrofit Roofing System will be equivalent to an FM 1-90 system when structural purlins are
spaced a maximum of 6-1/2' on center and theRUSS is secured with Carlisle HP or Purlin Fasteners and Polymer Seam Plates a
maximum of 6" on center into the purlins. ForFM Class 60 wind uplift equivalency,the purlins could be spaced a maximum of 6-1/2'
on center with the RUSS secured with Carlisle Fasteners and 2" diameter Polymer Seam Plates spaced a maximum of 12" on center
into the purlins.
As a standard FM Approvals requirement, additional membrane and insulation securement is necessary in the corner and/or perimeter
areas as outlined in FM Loss Prevention Data Sheets 1-28, 1-29 and 1-31. These bulletins should be reviewed in their entirety for
specific requirements concerning insulation types, fastening enhancements and other items that may be necessary.
Purlin SpacingFastener/Plate SpacingSure-Tough and Sure-Tough FR
1-90
HP Purlin/Piranha
60 Inches
12"1-60
(RoofNAV Number) - For selected systems using 1/4" thick Gypsum top layer.
Purlin SpacingFastener/Plate SpacingSure-Tough and Sure-Tough FR
6"1-90
HP Purlin/Piranha
60 Inches
12"1-60
(RoofNAV Number) - For selected systems using 1/4" thick Gypsum top layer.
<< TABLE OF CONTENTS
tğŭĻ ЊЎ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "B" Loose Laid Ballasterd Roofing Systems (24)(25)
.045" or .060" Sure-Seal FR Non-Reinforced EPDM Membrane
Membrane Type:
.060" or .075" Sure-Tough EPDM Membrane
UL Class "A"
Insulation
Deck TypeInsulation ThicknessMaximum Slope
(UL Classified)
2"
Any UL Classified InsulationAny
Non-Combustible and Combustible
New Construction:
None or HP Protective Mat (Refer to Carlisle
N/A2"
Specifications for requirements)
Approved Lightweight Insulating Concrete
FM Laboratories Approvals
Calorimeter Tests for the Design "B" Ballasted Roofing System
All constructions listed in the FM Approvals (FM) Approval Guide are Class 1 A, B or C fire rated and minimum Class 60 uplift rated.
Because of the nature of the uplift testing (pressurizing the underside of the deck to minimum 60 pounds per square foot), ballasted systems cannot be tested. If the ballasted system
was tested, it would only require approximately 10-15 pounds per square foot of uplift pressure before movement of the stone and membrane would occur. In reality, ballasted systems
are capable of resisting much higher wind forces.
Although ballasted systems are not formally FM approved, FM Approvals conducted research fire tests on Carlisle's Sure-Seal Design "B" Ballasted Roofing System. Two (2) test
panels were constructed which consisted of a 22-gauge steel deck, 5/8" thick Type X core gypsum board, 0.0015" aluminum vapor retarded and 4-1/4" Sure-Seal EPS insulation. The
following results were obtained:
Maximum Average Rate of Fuel
Contribution (Btu/Square Feet/Minutes) for various intervals of time
3 Minutes5 Minutes10 MinutesAverage
FM Class 1 Standard385365340270
Allowable Deviation25252015
Test Panel No. 2 *1241038831
* The fuel contribution rates developed for Test Panel No. 2 were equivalent to Test Panel No. 1
The conclusion of the research report was that the Ballasted System Panels had met the fire hazard requirement for Class 1 insulated steel deck roof construction.
Additionally, FM Approvals has published Loss Prevention Data Sheet 1-29, Above Deck Roof components that outlines general guidelines for ballast criteria depending on project
conditions (building height, parapet height, location, etc.). According to this bulletin, FM Approvals' loss experience has been very favorable for single-ply Ballasted Roofing Systems
when designed in accordance with this published criteria.
Although FM does not formally approve Ballasted Systems, job-by-job acceptance can be obtained when FM Approvals is the insurance underwriter by contacting the local FM office
for requirements.
<< TABLE OF CONTENTS
tğŭĻ ЊЏ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "C" Loose Laid Protected Roofing System (26)(27)
.045" or .060 Sure-Seal FR Non-Reinforced EPDM Membrane
Membrane Type:
.060" or .075" Sure-Though EPDM Membrane
UL Class "A"
Deck TypeInsulation (28)Insulation ThicknessMaximum Slope
Foamular 4048" Max.2"
Non-Combustible and Combustible
Dow Styrofoam Roofmate or Plazamate4" Max.2"
<< TABLE OF CONTENTS
tğŭĻ ЊА ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "A" Adhered Roofing Systems
Non-Combustible - ANSI/UL 790 Spread of Flame Test - Class A
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure Tough .045", .060", or .075"
Membrane
Sure-Tough FR .045", .060", or .075"
Type:
Sure-White .060" or .090
Non-Combustible: Steel; St. Concrete; Gypsum; Tectum (Min. 2" thick)
Maximum Slope
System IDDeck TypeInsulationCover Board
Sure-Seal FR Sure-Tough
Sure-ToughSure-White
NonreinforcedFR
HP-H, SecurShield, SecurShield HD,
1SecurShield HD Plus or SecurShield HD N/A1/2"1/2"3/4"1/2"
Composite-any combination, any thickness
Any UL Classified EPS or XPS Insulation,
2HD, SecurShield HD Plus or 1"1"2"1-1/2"
any thickness
SecurShield HD Composite
SecurShield HD Composite over any UL
3N/A1/2"1/2"3/4"1/2"
Classified EPS or XPS Insulation, maximum
1.25 pcf, any thickness
Insulfoam HD Composite or Insulfoam HD
4Non-Combustible Composite over Insulfoam EPS, any thickness N/A1/2"1/2"3/4"1/2"
and density.
Any UL Classified Insulation, any thickness
5Unlimited3"4"3"
(OPTIONAL)Gypsum-Fiber Roof Board
Any UL Classified Insulation, any thickness
6Unlimited3"4"3"
(OPTIONAL)Prime Roof Boards
Any UL Classified Insulation, any thickness
71"1"2-1/2"1-1/2"
(OPTIONAL)Board
Any UL Classified Insulation, any thickness
81"1"2-1/2"1-1/2"
(OPTIONAL)
HNB
Cellular Lightweight
9N/AN/A1"1"2-1/2"1-1/2"
Concrete
Precast concrete with
10N/AN/A1"1"2-1/2"1-1/2"
grouted joints
Structural (poured-in-
11N/AN/A1"1"2-1/2"1-1/2"
place) concrete
<< TABLE OF CONTENTS
tğŭĻ ЊБ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "A" Adhered Roofing Systems
UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test - Class A
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure Tough .045", .060", or .075"
Membrane
Sure-Tough FR .045", .060", or .075"
Type:
Sure-White .060" or .090
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in.
(minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Maximum Slope
Thermal
System IDBarrier/Base InsulationCover Board (30)
Sure-Seal FR
Sheet
Sure-ToughSure-Tough FRSure-White
Nonreinforced
Combustible - ANSI/UL 790 Spread of Flame Test-Class A
SECUROCK® Any UL Classified Carlisle Polyisocyanurate
1N/A1/2"1/2"1/2"1/2"
Gypsum Fiber Insulation, any combination, any thickness.
Roof Boards (29)
Any UL Classified Carlisle Polyisocyanurate
2DensDeck Prime N/A1/2"1/2"1/2"1/2"
Insulation, any combination, any thickness.
Roof Boards (29)
3N/AN/A1/2"1/2"1/2"1/2"
SecurShield HD Composite. (29)(31)
4N/AN/A1/2"1/2"1/2"1/2"
H Insulation. (29)(32)
Carlisle FR Base
5N/A1/2"1/2"1/2"1/2"
SheetComposite. (29)(32)
6N/ASecurShield HD or 1/2"1/2"1/2"1/2"
Polyisocyanurate Insulation, any combination. (29)
SecurShield HD Plus
Carlisle FR Base
7SecurShield HD or 1/2"1/2"1/2"1/2"
SheetPolyisocyanurate Insulation, any combination. (29)
SecurShield HD Plus
8N/AN/A1/2"1/2"1/2"1/2"
9N/ASecurShield HD or 1/2"1/2"1/2"1/2"
Insulation. (29)(34)
SecurShield HD Plus
10N/AN/A1/2"1/2"1/2"1/2"
(29)(34)
11N/AN/A1/2"1/2"1/2"1/2"
12N/AN/A1/2"1/2"1/2"1/2"
Any UL Classified Carlisle Polyisocyanurate SECUROCK®
13N/AUnlimited3"4"3"
Insulation, any combination, any thickness.Gypsum Fiber Roof
Board (29)
Any UL Classified Insulation, any thickness SECUROCK®
14N/A2"2"2"2"
(OPTIONAL)Gypsum Fiber Roof
Board (29)
Any UL Classified Insulation, any thickness SECUROCK®
15N/AUnlimited3"4"3"
(OPTIONAL)Gypsum Fiber Roof
Board (29)
tğŭĻ ЊВ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "A" Adhered Roofing Systems
UL Approval - Combustible - ANSI/UL 790 Spread of Flame Test - Class A
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure Tough .045", .060", or .075"
Membrane
Sure-Tough FR .045", .060", or .075"
Type:
Sure-White .060" or .090
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in.
(minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Maximum Slope
Thermal
System IDBarrier/Base InsulationCover Board (30)
Sure-Seal FR
Sheet
Sure-ToughSure-Tough FRSure-White
Nonreinforced
Combustible - ANSI/UL 790 Spread of Flame Test-Class A
One Ply of Type Any UL Classified Insulation, any thickness SECUROCK®
163"3"3"3"
G2(OPTIONAL)Gypsum Fiber Roof
Board (29)
Any UL Classified Insulation, any thickness
17N/ADensDeck Prime Unlimited3"4"3"
(OPTIONAL)
Roof Boards (29)
Three or Two
Any UL Classified Carlisle Polyisocyanurate
18layers of Carlisle N/A1/2"1/2"1/2"1/2"
Insulation, any combination, any thickness.
FR Base Sheet
<< TABLE OF CONTENTS
tğŭĻ ЋЉ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "A" Adhered Roofing Systems
Combustible - ANSI/UL 790 Spread of Flame Test - Class B
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure Tough .045", .060", or .075"
Membrane
Sure-Tough FR .045", .060", or .075"
Type:
Sure-White .060" or .090
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-
in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Maximum Slope
Thermal
System IDBarrier/Base InsulationCover Board
Sure-Seal FR
Sure-ToughSure-Tough FRSure-White
Sheet
Nonreinforced
Combustible - ANSI/UL 790 Spread of Flame Test-Class B
1N/AN/A1/2"1/2"1/2"1/2"
Composite. (35)(36)
2N/ASecurShield HD or 1/2"1/2"1/2"1/2"
Polyisocyanurate Insulation. (35)
SecurShield HD Plus
3N/AN/A1/2"1/2"1/2"1/2"
<< TABLE OF CONTENTS
tğŭĻ ЋЊ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Underwriters Laboratories Approvals
Design "A" Adhered Roofing Systems
Combustible and Non-Combustible - ANSI/UL 790 Spread of Flame Test (Class C)
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure Tough .045", .060", or .075"
Membrane
Sure-Tough FR .045", .060", or .075"
Type:
Sure-White .060" or .090
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels or waferboard panels); 15/32-in.
(minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Non-Combustible: Steel, St. Concrete, Gypsum or Tectum (Min. 2" thick)
Maximum Slope
Thermal
System IDBarrier/Base InsulationCover Board
Sure-Seal FR
Sure-ToughSure-Tough FRSure-White
Sheet
Nonreinforced
Combustible - ANSI/UL 790 Spread of Flame Test-Class C
2" layer of any UL Classified Carlisle
1N/AN/AUnlimitedUnlimitedUnlimitedUnlimited
Polyisocranurate Isulation
Non-Combustible - ANSI/UL 790 Spread of Flame Test-Class C
Any layer of UL Classified Carlisle
1N/AN/AUnlimitedUnlimitedUnlimitedUnlimited
Polyisocyanurate Insulation.
Existing UL Rating Retained
Combustible
(Directly over existing Class A, B or C)
Sure-Seal FR Nonreinforced .045', .060" or .090"
Membrane
Sure-White .060" or .090
Type:
Combustible: 7/16-in. (minimum) thick non-veneer APA-rated sheathing (oriented strand board panels, structural particleboard panels, composite panels
or waferboard panels); 15/32-in. (minimum) thick plywood 3/4 in. (minimum) wood; Tectum (less than 2" thick)
Maximum Slope
System IDDeck TypeExisting SubstrateInsulationBonding Adhesive
Sure-Seal FR
Sure-White
Nonreinforced
Existing min. UL Class "C" rated Type III or
1N/AIV Smooth Asphalt BUR, Mineral Cap Sheet None90-8-30A/Low VOC1/2"1/2"
or Modified Bitumen to remain
<< TABLE OF CONTENTS
tğŭĻ ЋЋ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield HD Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
284927-0-0
FM Approved Loose laid1/2" SecurShield HD12 (2.67 sq. ft)1-75---
(90-8-30A)
385922-0-0385923-0-0
FM Approved Loose laid 1/2" SecurShield HD16 (2 sq. ft)1-90385912-0-0385913-0-0
(90-8-30A)(90-8-30A)
6" ribbons of
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.) 1/2" SecurShield HD1-90351267-0-0351268-0-0-351269-0-0
Olybond 500 BA
Min. 2" Polyiso HP-H8 (4 sq. ft) 1/2" SecurShield HD6" ribbons of FAST1-90----
Min. 1/2" Polyiso HP-H 18 (1.8 sq. ft.) 1/2" SecurShield HD6" ribbons of FAST1-105----
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)1/2" SecurShield HD4" ribbons of FAST 1-150341962-0-0---
325931-0-0325996-0-0325998-0-0
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)1/2" SecurShield HD4" ribbons of FAST 1-165-
(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1/2" DensDeckSecurShield HD over
16 (2 sq. ft.)6" ribbons of FAST1-90----
Prime or SecurockPolyiso HP-H
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1/2" DensDeck1/2" SecurShield HD over
16 (2 sq. ft.)12" ribbons of FAST 1-90389422-0-0---
Prime or 5/8" SecurockMin. 1-1/2" Polyiso HP-H
Concrete Deck
Min. 1/2" Polyiso HP-H 12" ribbons of FAST 1/2" SecurShield HD12" ribbons of FAST 1-315343383-0-0344366-0-0-344369-0-0
Min. 1/2" Polyiso HP-H 12" ribbons of FAST 1/2" SecurShield HD12" ribbons of FAST 1-225----
12" ribbons of12" ribbons of
Min. 1/2" Polyiso HP-H 1/2" SecurShield HD1-240----
Olybond 500 BA Olybond 500 BA
Min. 1/2" Polyiso HP-HHot Asphalt 1/2" SecurShield HDHot Asphalt1-240----
12" ribbons of12" ribbons of
Min. 1/2" Polyiso HP-H 1/2" SecurShield HD1-255----
Carlisle One StepCarlisle One Step
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-240
----
Cav-Grip
Min. 1/2" Polyiso HP-H12" ribbons of FAST1/2" SecurShield HD12" ribbons of FAST 1-150
364530-0-0 364572-0-0364609-0-0364613-0-0
702 LV
1-90
----
702
tğŭĻ ЋЌ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield HD Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" Polyiso HP-H 12" ribbons of FAST 1/2" SecurShield HD12" ribbons of FAST 1-150392983-0-0392987-0-0392991-0-0392998-0-0
Tectum Deck
Min. 1-1/2" Polyiso HP-H Full-Coverage FAST 1/2" SecurShield HDFull-Coverage FAST1-150----
12" ribbons of 12" ribbons of
Min. 1-1/2" Polyiso HP-H 1/2" SecurShield HD1-90----
Olybond 500 BAOlybond 500 BA
Gypsum Deck Tear-Off
Min. 1-1/2" Polyiso HP-H Full-Coverage FAST 1/2" SecurShield HDFull-Coverage FAST1-90----
12" ribbons of12" ribbons of
Min. 1-1/2" Polyiso HP-H 1/2" SecurShield HD1-90----
Olybond 500 BAOlybond 500 BA
Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
FM Approved Loose laid 1/2" SecurShield HD12 (2.67 sq. ft)1-75----
FM Approved Loose laid 1/2" SecurShield HD16 (2 sq. ft)1-90----
-- 1/2" SecurShield HD12 (2.67 sq. ft)1-75----
-- 1/2" SecurShield HD16 (2 sq. ft)1-90----
Min. 1-1/2" Polyiso HP-H 4" ribbons of FAST 1/2" SecurShield HD4" ribbons of FAST 1-135----
-- 1/2" SecurShield HD4" ribbons of FAST 1-135----
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" Polyiso HP-H 4" ribbons of FAST 1/2" SecurShield HD4" ribbons of FAST1-135----
-- 1/2" SecurShield HD4" ribbons of FAST 1-135----
<< TABLE OF CONTENTS
tğŭĻ ЋЍ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield HD Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see notes Rating
(Max. thickness 36")
see notes 38, 39 & 40)38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
295759-0-0299369-0-0296329-0-0
1/2" SecurShield HD12 (2.67 sq. ft)1-75-
--
(90-8-30A)(90-8-30A)(90-8-30A)
1/2" SecurShield HD16 (2 sq. ft)1-90----
--
1/2" SecurShield HD6" ribbons of FAST 1-90309444-0-0309401-0-0309461-0-0-
--
--1/2" SecurShield HD4" ribbons of FAST1-150----
Concrete Deck
Min. 1/2" Polyiso HP-H6" ribbons of FAST1/2" SecurShield HD6" ribbons of FAST 1-150----
--1/2" SecurShield HD6" ribbons of FAST 1-150----
Tectum Deck
--1/2" SecurShield HDFull-Coverage FAST1-150----
--1/2" SecurShield HD6" ribbons of FAST1-90----
--1/2" SecurShield HD4" ribbons of FAST1-150----
12" ribbons of
--1/2" SecurShield HD1-90----
Olybond 500 BA
Gypsum Deck Tear-Off
--1/2" SecurShield HD6" ribbons of FAST1-90----
12" ribbons of
--1/2" SecurShield HD1-90----
Olybond 500 BA
<< TABLE OF CONTENTS
tğŭĻ ЋЎ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield HD Plus Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
1/2" SecurShield325739-0-0325972-0-0
Min. 1-1/2" Polyiso HP-HLoose laid8 (4 sq. ft)1-90341318-0-0341325-0-0
HD Plus(90-8-30A)(90-8-30A)
1/2" SecurShield325772-0-0325981-0-0325983-0-0
Min. 1-1/2" Polyiso HP-HLoose laid18 (1.8 sq. ft)1-120-
HD Plus(90-8-30A)(90-8-30A)(90-8-30A)
1/2" SecurShield
Min. 1-1/2" Polyiso HP-HLoose laid24 (1.33 sq. ft)1-150374515-0-0---
HD Plus
1/2" SecurShield325920-0-0325984-0-0325985-0-0
Min. 1-1/2" Polyiso HP-HLoose laid24 (1.33 sq. ft.)1-165-
HD Plus(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1-1/2" Polyiso HP-H or 1/2" SecurShield325921-0-0325986-0-0325987-0-0
Loose laid24 (1.33 sq. ft)1-225 (42)-
SecurShieldHD Plus(90-8-30A)(90-8-30A)(90-8-30A)
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.)6" ribbons of FAST1-90----
HD Plus
1/2" SecurShield
Min. 2" Polyiso HP-H8 (4 sq. ft)6" ribbons of FAST1-90----
HD Plus
1/2" SecurShield325930-0-0325991-0-0325993-0-0
Min. 1-1/2" Polyiso HP-H18 (1.8 sq. ft.)6" ribbons of FAST1-105-
HD Plus(90-8-30A)(90-8-30A)(90-8-30A)
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)4" ribbons of FAST1-150----
HD Plus
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)4" ribbons of FAST1-165----
HD Plus
Min. 1/2" DensDeck Prime or SecurShield HD Plus
16 (2 sq. ft.)6" ribbons of FAST1-90----
Securockover Polyiso HP-H
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
1/2" SecurShield HD
Min. 1/2" DensDeck Prime or 5/8"
16 (2 sq. ft.)Plus over Min. 1-1/2" 12" ribbons of FAST 1-90389422-0-0---
Securock
Polyiso HP-H
Concrete Deck
1/2" SecurShield
Min. 1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST 1-315343383-0-0344366-0-0-344369-0-0
HD Plus
1/2" SecurShield
Min. 1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST 1-225----
HD Plus
12" ribbons of 1/2" SecurShield12" ribbons of
Min. 1/2" Polyiso HP-H 1-240----
Olybond 500 BAHD PlusOlybond 500 BA
1/2" SecurShield
Min. 1/2" Polyiso HP-H Hot AsphaltHot Asphalt1-240----
HD Plus
12" ribbons of 1/2" SecurShield12" ribbons of
Min. 1/2" Polyiso HP-H 1-255----
Carlisle One StepHD PlusCarlisle One Step
tğŭĻ ЋЏ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield HD Plus Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255
----
Cav-Grip
364530-0-0 364572-0-0364609-0-0364613-0-0
Min. 1/2" Polyiso HP-H or1/2" SecurShield
1-150
12" ribbons of FAST12" ribbons of FAST
(all 3 primers listed (all 3 primers (all 3 primers (all 3 primers
SecurShieldHD Plus
702 LV
above)listed above)listed above)listed above)
1-90
----
702
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
1/2" SecurShield
Min. 1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST 1-150392983-0-0392987-0-0392991-0-0392998-0-0
HD Plus
Tectum Deck
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTFull-Coverage FAST1-150----
HD Plus
12" ribbons of1/2" SecurShield12" ribbons of
Min. 1-1/2" Polyiso HP-H 1-90----
Olybond 500 BAHD PlusOlybond 500 BA
Gypsum Deck Tear-Off
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTFull-Coverage FAST1-90----
HD Plus
12" ribbons of Olybond 500 1/2" SecurShield12" ribbons of
Min. 1-1/2" Polyiso HP-H 1-90----
BAHD Plus Olybond 500 BA
Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
1/2" SecurShield
FM Approved Loose laid8 (4 sq. ft)1-90----
HD Plus
1/2" SecurShield
--8 (4 sq. ft)1-90----
HD Plus
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H 4" ribbons of FAST4" ribbons of FAST 1-135----
HD Plus
1/2" SecurShield
--4" ribbons of FAST 1-135----
HD Plus
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
1/2" SecurShield
Min. 1/2" Polyiso HP-H 4" ribbons of FAST4" ribbons of FAST1-135----
HD Plus
1/2" SecurShield
--4" ribbons of FAST 1-135----
HD Plus
<< TABLE OF CONTENTS
tğŭĻ ЋА ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield HD Plus Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
1/2" SecurShield325979-0-0
8 (4 sq. ft)1-90325757-0-0325976-0-0-
--
HD Plus(90-8-30A)
1/2" SecurShield
--6" ribbons of FAST1-90---
HD Plus
1/2" SecurShield
--4" ribbons of FAST1-150----
HD Plus
Concrete Deck
1/2" SecurShield
Min. 1/2" Polyiso HP-H 6" ribbons of FAST6" ribbons of FAST 1-150----
HD Plus
1/2" SecurShield
6" ribbons of FAST 1-150----
HD Plus
Tectum Deck
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTFull-Coverage FAST1-150----
HD Plus
12" ribbons of 1/2" SecurShield12" ribbons of
Min. 1-1/2" Polyiso HP-H 1-90----
Olybond 500 BAHD Plus Olybond 500 BA
Gypsum Deck Tear-Off
1/2" SecurShield
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTFull-Coverage FAST1-90----
HD Plus
12" ribbons of 1/2" SecurShield12" ribbons of
Min. 1-1/2" Polyiso HP-H 1-90----
Olybond 500 BAHD PlusOlybond 500 BA
<< TABLE OF CONTENTS
tğŭĻ ЋБ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Polyiso HP-H Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
6310-0-0
Min. 1-1/2" Polyiso HP-H16 (2 sq. ft)--1-904069-0-04069-0-0-
(90-8-30A)
4089-0-04089-0-04089-0-0
Min. 2" Polyiso HP-H8 (4 sq. ft)--1-90-
(90-8-30A)(90-8-30A)(90-8-30A)
131096-0-0131096-0-0131096-0-0131118-0-0
Min. 2" Polyiso HP-H20 (1.6 sq. ft)--1-150
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.)Min. 1-1/2" Polyiso HP-H12" ribbons of FAST1-90----
Min. 2" Polyiso HP-H8 (4 sq. ft)Min. 2" Polyiso HP-H12" ribbons of FAST1-90344604-0-0---
Min. 1-1/2" Polyiso HP-H18 (1.8 sq. ft.)Min. 1-1/2" Polyiso HP-H6" ribbons of FAST1-105----
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)Min. 1-1/2" Polyiso HP-H4" ribbons of FAST1-165----
Min. 1/2" DensDeck
16 (2 sq. ft.)Min. 1-1/2" Polyiso HP-H12" ribbons of FAST1-90----
Prime or Securock
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1/2" DensDeck
16 (2 sq. ft.)Min. 1-1/2" Polyiso HP-H12" ribbons of FAST 1-105----
Prime or Securock
Concrete Deck
Min. 1/2" Polyiso HP-H 12" ribbons of FAST--1-315----
12" ribbons of269891-0-0269891-0-0
Min. 1/2" Polyiso HP-H --1-315--
Olybond 500 BA(90-8-30A)(90-8-30A)
83581-0-083581-0-083581-0-0
Min. 1-1/2" Polyiso HP-HCarlisle One Step--1-465-
(90-8-30A)(90-8-30A)(90-8-30A)
240000-0-0240000-0-0240000-0-0241715-0-0
Min. 1" Polyiso HP-H Hot Asphalt--1-300
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255
----
Cav-Grip
1-195
----
702 LV
Min. 1/2" Polyiso HP-H12" ribbons of FAST--
343380-0-0343380-0-0343380-0-0343381-0-0
1-90
(all 3 primers (all 3 primers (all 3 primers (all 3 primers
702
listed above)listed above)listed above)listed above)
tğŭĻ ЋВ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Polyiso HP-H Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" Polyiso HP-H 12" ribbons of FASTMin. 1-1/2" Polyiso HP-H12" ribbons of FAST 1-330----
Tectum Deck
83126-0-083126-0-083126-0-0
Min. 1-1/2" Polyiso HP-H16 (2 sq. ft)--1-90-
(90-8-30A)(90-8-30A)(90-8-30A)
205459-0-0205459-0-0205459-0-0
Min. 2" Polyiso HP-HFull-Coverage FAST--1-150-
(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of
Min. 1-1/2" Polyiso HP-H --1-90----
Olybond 500 BA
Gypsum Deck Tear-Off
7451-0-07451-0-07451-0-07418-0-0
Min. 1-1/2" Polyiso HP-H16 (2 sq. ft)--1-90
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
193358-0-01933858-0-01933858-0-0193373-0-0
Min. 1" Polyiso HP-HFull-Coverage FAST--1-90
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of 12" ribbons of 83278-0-083278-0-083278-0-097896-0-0
Min. 1-1/2" Polyiso HP-HMin. 1-1/2" Polyiso HP-H1-90
Carlisle One StepCarlisle One Step(90-8-30A) (90-8-30A) (90-8-30A) (90-8-30A)
12" ribbons of 82850-0-082850-0-082850-0-097401-0-0
Min. 1-1/2" Polyiso HP-H--1-240
Olybond 500 BA(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
Min. 1-1/2" Polyiso HP-H16 (2 sq. ft)--1-90----
Min. 2" Polyiso HP-H8 (4 sq. ft)--1-90----
Min. 2" Polyiso HP-H20 (1.6 sq. ft)--1-150----
Min. 1" Polyiso HP-H4" ribbons of FAST --1-135----
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" Polyiso HP-H 4" ribbons of FAST--1-135----
<< TABLE OF CONTENTS
tğŭĻ ЌЉ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Polyiso HP-H Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation LayerTop Insulation
Nonreinforced
(mechanically fastened (mechanically fastened see Rating
(Max. thickness 36")Layer
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
Min. 1/2" Polyiso HP-H20 (1.6 sq. ft)--1-90164635-0-0164635-0-0164635-0-0-
1" Polyiso HP-H6" ribbons of FAST --1-90----
12" ribbons of 278907-0-0278907-0-0
Min. 1/2" Polyiso HP-H--1-90--
Olybond 500 BA(90-8-30A)(90-8-30A)
Concrete Deck
Min. 1/2" Polyiso HP-H12" ribbons of FAST --1-90----
Tectum Deck
1" Polyiso HP-H16 (2 sq. ft)--1-90371856-0-0371856-0-0--
1" Polyiso HP-HFull-Coverage FAST--1-150----
12" ribbons of
1" Polyiso HP-H--1-90----
Olybond 500 BA
Gypsum Deck Tear-Off
9519-0-09519-0-09519-0-0
Min. 1/2" Polyiso HP-H16 (2 sq. ft)--1-90-
(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1/2" Polyiso HP-HFull-Coverage FAST--1-90144196-0-0144196-0-0144196-0-0-
12" ribbons of
1" Polyiso HP-H--1-90---
-
Olybond 500 BA
<< TABLE OF CONTENTS
tğŭĻ ЌЊ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield and SecurShield HD Composite Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
6307-0-0
Min. 1-1/2" SecurShield or 6310-0-06314-0-06310-0-0
16 (2 sq. ft)--1-90(90-8-30A)
SecurShield HD Composite(90-8-30A)(90-8-30A)(90-8-30A)
SecurShield Only
4089-0-04089-0-04089-0-0
Min. 2" SecurShield or (90-8-30A)(90-8-30A)(90-8-30A)
8 (4 sq. ft)--1-90-
SecurShield HD CompositeSecuShield HD SecuShield HD SecuShield HD
Comp. OnlyComp. OnlyComp. Only
247401-0-0131118-0-0
Min. 2" SecurShield or 247402-0-0
20 (1.6 sq. ft.)--1-150301420-0-0(90-8-30A)(90-8-30A)
SecurShield HD Composite(90-8-30A)
SecurShield OnlySecurShield Only
245502-0-0245502-0-0245503-0-0
Min. 2" SecurShield or 1-225245201-0-0
32 (1 sq. ft.)--(90-8-30A)(90-8-30A)(90-8-30A)
SecurShield HD Composite(42)(90-8-30A)
SecurShield OnlySecurShield OnlySecurShield Only
Min. 1-1/2" SecurShield or
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.)SecurShield HD 12" ribbons of FAST1-90----
Composite
Min. 2" SecurShield or
Min. 2" Polyiso HP-H8 (4 sq. ft)SecurShield HD 12" ribbons of FAST1-90344604-0-0344603-0-0--
Composite
Min. 1-1/2" SecurShield or
Min. 1-1/2" Polyiso HP-H18 (1.8 sq. ft.)SecurShield HD 6" ribbons of FAST1-105----
Composite
Min. 1-1/2" SecurShield or
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)SecurShield HD 4" ribbons of FAST1-165----
Composite
Min. 1-1/2" SecurShield or 252110-0-0252110-0-0
Min. 1/2" DensDeck Prime 16 (2 sq. ft.)SecurShield HD 12" ribbons of FAST1-90(90-8-30A)-(90-8-30A)-
CompositeSecurShield OnlySecurShield Only
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1-1/2" SecurShield or
Min. 1/2" DensDeck 296822-0-0296822-0-0296822-0-0
16 (2 sq. ft.)SecurShield HD 12" ribbons of FAST 1-90-
Prime or 5/8" Securock(90-8-30A)(90-8-30A)(90-8-30A)
Composite
Concrete Deck
Min. 1/2" SecurShield or
12" ribbons of FAST --1-225----
SecurShield HD Composite
222685-0-0222685-0-0222686-0-0
Min. 1-1/2" SecurShield or 12" ribbons of
--1-300(90-8-30A)-(90-8-30A)(90-8-30A)
SecurShield HD CompositeOlybond 500 BA
SecurShield OnlySecurShield OnlySecurShield Only
Min. 1/2" SecurShield or Secur
Hot Asphalt--1-300----
Shield HD Composite
tğŭĻ ЌЋ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield and SecurShield HD Composite Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255
----
Cav-Grip
Min. 1/2" SecurShield or Secur
12" ribbons of FAST --
1-195
Shield HD Composite
----
702 LV
1-90
----
702
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1-1/2" SecurShield or
Min. 1-1/2" Polyiso HP-H12" ribbons of FASTSecurShield HD 12" ribbons of FAST 1-150----
Composite
Tectum Deck
Min. 1-1/2" SecurShield or
16 (2 sq. ft)--1-90----
SecurShield HD Composite
Min. 1-1/2" SecurShield or
Full-Coverage FAST--1-150----
SecurShield HD Composite
Min. 1-1/2" SecurShield or 12" ribbons of
--1-90----
SecurShield HD CompositeOlybond 500 BA
Gypsum Deck Tear-Off
Min. 1-1/2" SecurShield or
16 (2 sq. ft)--1-90----
SecurShield HD Composite
Min. 1-1/2" SecurShield or
Full-Coverage FAST--1-90----
SecurShield HD Composite
Min. 1-1/2" SecurShield or 12" ribbons of
--1-90----
SecurShield HD CompositeOlybond 500 BA
(Celcore) Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
Min. 1-1/2" SecurShield or
16 (2 sq. ft)--1-75----
SecurShield HD Composite
Min. 2" SecurShield or
8 (4 sq. ft)--1-90----
SecurShield HD Composite
Min. 2" SecurShield or
20 (1.6 sq. ft.)--1-150----
SecurShield HD Composite
Min. 2" SecurShield or
32 (1 sq. ft.)--1-225----
SecurShield HD Composite
Min. 1-1/2" SecurShield or
4" ribbons of FAST --1-135----
SecurShield HD Composite
Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" SecurShield or
4" ribbons of FAST --1-135----
SecurShield HD Composite
<< TABLE OF CONTENTS
tğŭĻ ЌЌ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
SecurShield Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation LayerTop Insulation
NonreinforcedFR
(mechanically fastened (mechanically fastened see Rating
(Max. thickness 36")Layer
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
325737-0-0
2" SecurShield20 (1.6 sq. ft)--1-150---
(90-8-30A)
Concrete Deck
Min. 1/2" SecurShield 12" ribbons of FAST --1-90----
Tectum Deck
1" SecurShield20 (1.6 sq. ft)--1-90----
1" SecurShieldFull-Coverage FAST--1-150----
12" ribbons of
1" SecurShield--1-90----
Olybond 500 BA
Gypsum Deck Tear-Off
1" SecurShield20 (1.6 sq. ft)--1-90----
1" SecurShieldFull-Coverage FAST--1-90----
12" ribbons of
1" SecurShield--1-90----
Olybond 500 BA
<< TABLE OF CONTENTS
tğŭĻ ЌЍ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Securock Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
FM Approved Loose laidMin. 1/4" Securock12 (2.66 sq. ft)1-75----
16 (2 sq. ft)212270-0-0270074-0-0270076-0-0270077-0-0
FM Approved Loose laidMin. 1/4" Securock1-90
SecurFAST Plates(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
FM Approved Loose laidMin. 1/2" Securock10 (3.2 sq. ft)1-90302948-0-0302946-0-0302949-0-0302947-0-0
8 (4 sq. ft)
FM Approved Loose laidMin. 1/2" Securock1-90----
SecurFAST Plates
8 (4 sq. ft)
FM Approved Loose laidMin. 1/2" Securock1-90----
SecurFAST Plates
FM Approved Loose laidMin. 5/8" Securock8 (4 sq. ft)1-90----
6 (5.33 sq. ft)
FM Approved Loose laidMin. 5/8" Securock1-90----
SecurFAST Plates
224151-0-0225287-0-0225291-0-0225294-0-0
FM Approved Loose laidMin. 1/2" Securock20 (1.6 sq. ft)1-150
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
FM Approved Loose laidMin. 1/2" Securock32 (1 sq. ft)1-255----
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.)Min. 1/4" Securock12" ribbons of FAST 1-90386968-0-0---
187065-0-0 187061-0-0187071-0-0187105-0-0
Min. 2" Polyiso HP-H8 (4 sq. ft)Min. 1/2" Securock12" ribbons of FAST1-90
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1-1/2" Polyiso HP-H18 (1.8 sq. ft.)Min. 1/4" Securock6" ribbons of FAST1-105----
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)Min. 1/4" Securock4" ribbons of FAST1-165----
Min. 1/2" DensDeckMin. 1/4" Securock over
16 (2 sq. ft.)12" ribbons of FAST1-90----
Prime or 5/8" SecurockMin. 2" Polyiso HP-H
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1/2" Securock over
Min. 1/2" Polyiso HP-H 16 (2 sq. ft.)12" ribbons of FAST 1-90323293-0-0323293-0-0323293-0-0-
Min. 1-1/2" Polyiso HP-H
Concrete Deck
307927-0-0304589-0-0307963-0-0
Min. 1/2" Polyiso HP-H 12" ribbons of FASTMin. 1/4" Securock12" ribbons of FAST 1-315-
(90-8-30A)(90-8-30A)(90-8-30A)
tğŭĻ ЌЎ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Securock Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255
----
Cav-Grip
1-195
Min. 1-1/2" Polyiso HP-H 12" ribbons of FASTMin. 1/4" Securock12" ribbons of FAST
----
702 LV
1-90
----
702
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" Polyiso HP-H 12" ribbons of FASTMin. 1/4" Securock12" ribbons of FAST 1-330----
Tectum Deck
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTMin. 1/4" SecurockFull-Coverage FAST1-150----
12" ribbons of 12" ribbons of
Min. 1-1/2" Polyiso HP-H Min. 1/4" Securock1-90----
Olybond 500 BAOlybond 500 BA
Gypsum Deck Tear-Off
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTMin. 1/4" SecurockFull-Coverage FAST1-90----
12" ribbons of 12" ribbons of
Min. 1-1/2" Polyiso HP-H Min. 1/4" Securock1-90----
Olybond 500 BAOlybond 500 BA
Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
FM Approved Loose laidMin. 1/4" Securock12 (2.67 sq. ft)1-75----
FM Approved Loose laidMin. 1/2" Securock10 (3.2 sq. ft)1-90----
FM Approved Loose laidMin. 5/8" Securock8 (4 sq. ft)1-90----
FM Approved Loose laidMin. 1/2" Securock20 (1.6 sq. ft)1-150----
FM Approved Loose laidMin. 1/2" Securock32 (1 sq. ft)1-225----
Min. 1-1/2" Polyiso HP-H 4" ribbons of FASTMin. 1/2 "Securock4" ribbons of FAST 1-135----
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" Polyiso HP-H 4" ribbons of FASTMin. 1/2 "Securock4" ribbons of FAST 1-135----
12" ribbons of12" ribbons of
Min. 1/2" Polyiso HP-H Min. 1/2 "Securock1-240----
Olybond 500 BAOlybond 500 BA
<< TABLE OF CONTENTS
tğŭĻ ЌЏ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Securock Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Concrete Deck
Min. 1/2" Polyiso HP-H 12" ribbons of FASTMin. 1/4" Securock12" ribbons of FAST 1-90----
<< TABLE OF CONTENTS
tğŭĻ ЌА ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
DensDeck Prime Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
83097-0-0134403-0-097691-0-0
FM Approved Loose laidMin. 1/4" DensDeck Prime12 (2.67 sq. ft)1-90-
(90-8-30A)(90-8-30A)(90-8-30A)
FM Approved Loose laidMin. 1/2" DensDeck Prime10 (3.2 sq. ft)1-90350409-0-0350408-0-0350411-0-0350410-0-0
224154-0-0
Min. 1" Polyiso HP-HLoose LaidMin. 1/2" DensDeck Prime20 (1.6 sq. ft)1-105224152-0-0224156-0-0224159-0-0
(90-8-30A)
85854-0-083095-0-0134402-0-097689-0-0
FM Approved Loose laidMin. 5/8" DensDeck Prime8 (4 sq. ft)1-90
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/2" DensDeck Prime8 (4 sq.ft)1-90
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/4" DensDeck Prime18 (1.8 sq. ft)1-105382307-0-0---
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/2" DensDeck Prime18 (1.8 sq. ft)1-135383697-0-0---
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/2" DensDeck Prime20 (1.6 sq. ft)1-150383707-0-0---
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/2" DensDeck Prime32 (1 sq. ft)1-165384588-0-0---
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/2" DensDeck Prime32 (1 sq. ft)1-180 (41)384589-0-0---
Min. 1-1/2" Polyiso HP-HLoose laidMin. 1/2" DensDeck Prime32 (1 sq. ft)1-255 (42)387896-0-0--394645-0-0
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.)Min. 1/4" DensDeck Prime12" ribbons of FAST1-90----
187065-0-0187061-0-0187071-0-0187105-0-0
Min. 2" Polyiso HP-H8 (4 sq. ft)Min. 1/4" DensDeck Prime12" ribbons of FAST1-90
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1-1/2" Polyiso HP-H18 (1.8 sq. ft.)Min. 1/4" DensDeck Prime6" ribbons of FAST1-105----
Min. 1-1/2" Polyiso HP-H24 (1.33 sq. ft.)Min. 1/4" DensDeck Prime4" ribbons of FAST1-165----
Min. 1/4" DensDeck Prime
303438-0-0303440-0-0303441-0-0
Min. 1/2" DensDeck Prime 16 (2 sq. ft.)over 12" ribbons of FAST1-90303439-0-0
(90-8-30A)(90-8-30A)(90-8-30A)
1-1/2" Polyiso HP-H
tğŭĻ ЌБ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
DensDeck Prime Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1/4" DensDeck Prime
Min. 1/2" DensDeck
16 (2 sq. ft.)over 12" ribbons of FAST 1-90323293-0-0323293-0-0323293-0-0-
Prime or 5/8" Securock
1-1/2" Polyiso HP-H
Concrete Deck
Min. 1/2" Polyiso HP-H12" ribbons of FASTMin. 1/4" DensDeck Prime12" ribbons of FAST 1-315343383-0-0344366-0-0-344369-0-0
12" ribbons of
--Min. 1/4" DensDeck Prime1-465----
Olybond 500 BA
12" ribbons of 12" ribbons of86769-0-083587-0-086769-0-098207-0-0
Min. 1-1/2" Polyiso HP-HMin. 1/4" DensDeck Prime1-465
Carlisle One Step Carlisle One Step(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1/2" Polyiso HP-HHot AsphaltMin. 1/4" DensDeck PrimeHot Asphalt1-300----
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255274598-0-0274610-0-0274606-0-0
-
Cav-Grip (90-8-30A)(90-8-30A)(90-8-30A)
1-195
Min. 1" Polyiso HP-H Full-Coverage FASTMin. 1/4" DensDeck PrimeFull-Coverage FAST
----
702 LV
1-90274603-0-0274611-0-0
--
702(90-8-30A)(90-8-30A)
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" Polyiso HP-H 12" ribbons of FASTMin. 1/4" DensDeck Prime12" ribbons of FAST 1-330----
Tectum Deck
Min. 1-1/2" Polyiso HP-HFull-Coverage FASTMin. 1/4" DensDeck PrimeFull-Coverage FAST1-150----
12" ribbons of 12" ribbons of 83894-0-0134240-0-0 (90-97327-0-0
Min. 1-1/2" Polyiso HP-HMin. 1/4" DensDeck Prime1-9091835-0-0
Olybond 500 BAOlybond 500 BA(90-8-30A)8-30A)(90-8-30A)
Gypsum Deck Tear-Off
163461-0-0157782-0-0157783-0-0
Min. 1-1/2" Polyiso HP-HFull-Coverage FASTMin. 1/4" DensDeck PrimeFull-Coverage FAST1-90-
(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of 12" ribbons of 85902-0-0 83272-0-0 134289-0-097820-0-0
Min. 1-1/2" Polyiso HP-HMin. 1/4" DensDeck Prime1-90
Carlisle One StepCarlisle One Step(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of 12" ribbons of 84593-0-082831-0-0 134241-0-098382-0-0
Min. 1-1/2" Polyiso HP-HMin. 1/4" DensDeck Prime1-90
Olybond 500 BAOlybond 500 BA(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
tğŭĻ ЌВ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
DensDeck Prime Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
FM Approved Loose laidMin. 1/4" DensDeck Prime12 (2.67 sq. ft)1-90----
FM Approved Loose laidMin. 1/2" DensDeck Prime10 (3.2 sq. ft)1-90----
FM Approved Loose laidMin. 5/8" DensDeck Prime8 (4 sq. ft)1-90----
Min. 1-1/2" Polyiso HP-H4" ribbons of FASTMin. 1/2" DensDeck Prime4" ribbons of FAST 1-135----
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" Polyiso HP-H4" ribbons of FASTMin. 1/4" DensDeck Prime4" ribbons of FAST 1-135----
<< TABLE OF CONTENTS
tğŭĻ ЍЉ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
DensDeck Prime Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation Layer
NonreinforcedFR
(mechanically fastened Top Insulation Layer(mechanically fastened see notes Rating
(Max. thickness 36")
see notes 38, 39 & 40)38, 39 & 40)
RoofNAV Number
Concrete Deck
173671-0-0
Min. 1" Polyiso HP-H12" ribbons of FASTMin. 1/4" DensDeck Prime12" ribbons of FAST 1-75---
(90-8-30A)
<< TABLE OF CONTENTS
tğŭĻ ЍЊ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
HP Recovery Board Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Sure-ToughSure-Tough FRSure-White
Base Layer FasteningTop Layer Fastening
Nonreinforced
Base Insulation Layer
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
Min. 1/2" HP Recovery 270071-0-0270070-0-0270072-0-0270073-0-0
Min. 1-1/2" Polyiso HP-H Loose laid16 (2 sq. ft)1-90
Board(x-23 Only)(x-23 Only)(x-23 Only)(x-23 Only)
Min. 1/2" HP Recovery
Min. 1-1/2" Polyiso HP-H10 (3.2 sq. ft.)6" ribbons of FAST1-90---
Board
1/2"-1" HP Recovery 187065-0-0187061-0-0187071-0-0187105-0-0
Min. 2" Polyiso HP-H8 (4 sq. ft)12" ribbons of FAST1-90
Board(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1/2" DensDeck Prime or Min. 1/2" HP Recovery
16 (2 sq. ft.)6" ribbons of FAST1-90----
SecurockBoard
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1/2" HP Recovery
Min. 1/2" DensDeck Prime or
16 (2 sq. ft.)Board over Min. 1-1/2" 6" ribbons of FAST 1-90387389-0-0387390-0-0323293-0-0-
5/8" Securock
Polyiso HP-H
Concrete Deck
Min. 1/2" HP Recovery 160648-0-0160979-0-0160981-0-0
Min. 1-1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST 1-315-
Board(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of Min. 1/2" HP Recovery 12" ribbons of 229682-0-0229665-0-0229684-0-0229685-0-0
Min. 1-1/2" Polyiso HP-H 1-240
Olybond 500 BABoardOlybond 500 BA(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of Min. 1/2" HP Recovery 12" ribbons of86730-0-083491-0-0134301-0-097965-0-0
Min. 1-1/2" Polyiso HP-H 1-255
Carlisle One StepBoard Carlisle One Step(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1/2" HP Recovery
Min. 1" Polyiso HP-H Hot AsphaltHot Asphalt1-300----
Board
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255392406-0-0394204-0-0394205-0-0394206-0-0
Cav-Grip (90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Min. 1/2" HP Recovery
Min. 1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST
1-195
Board
----
702 LV
1-90
----
702
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" HP Recovery
Min. 1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST 1-330----
Board
tğŭĻ ЍЋ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
HP Recovery Board Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Sure-ToughSure-Tough FRSure-White
Base Layer FasteningTop Layer Fastening
Nonreinforced
Base Insulation Layer
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Tectum Deck
Min. 1/2" HP Recovery
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTFull-Coverage FAST1-90----
Board
12" ribbons of Min. 1/2" HP Recovery 12" ribbons of84581-0-0 83894-0-097327-0-0
Min. 1-1/2" Polyiso HP-H 1-90-
Olybond 500 BABoardOlybond 500 BA(90-8-30A)(90-8-30A)(90-8-30A)
Gypsum Deck Tear-Off
Min. 1/2" HP Recovery 163461-0-0157782-0-0 157783-0-0
Min. 1-1/2" Polyiso HP-H Full-Coverage FASTFull-Coverage FAST1-90-
Board(90-8-30A)(90-8-30A)(90-8-30A)
12" ribbons of Min. 1/2" HP Recovery 12" ribbons of 84593-0-082831-0-0134241-0-0 98382-0-0
Min. 1-1/2" Polyiso HP-H 1-90
Olybond 500 BABoardOlybond 500 BA(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
Cellular Lightweight Insulating Concrete Over Steel Decking (Min. 22 Gauge)
Min. 1/2" HP Recovery
FM Approved Loose laid16 (2 sq. ft)1-90----
Board
Min. 1/2" HP Recovery
Min. 1-1/2" Polyiso HP-H 4" ribbons FAST4" ribbons of FAST 1-90----
Board
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" HP Recovery
Min. 1" Polyiso HP-H12" ribbons FAST 12" ribbons FAST 1-135309956-0-50914309932-0-50914309960-0-50914309964-0-50914
Board
<< TABLE OF CONTENTS
tğŭĻ ЍЌ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
HP Recovery Board Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer Adhesive:
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see notes Rating
(Max. thickness 36")
see notes 38, 39 & 40)38, 39 & 40)
RoofNAV Number
Concrete Deck
Min. 1/2" HP Recovery
Min. 1/2" Polyiso HP-H 12" ribbons of FAST12" ribbons of FAST 1-90----
Board
<< TABLE OF CONTENTS
ЍЍ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
OSB Ratings - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-Tough FRSure-White
Base Insulation Layer
Nonreinforced
(mechanically fastened Top Insulation Layer(mechanically fastened see Rating
(Max. thickness 36")
see notes 38, 39 & 40)notes 38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
FM Approved Loose laid7/16" OSB17 (1.8 sq. ft)1-150----
Steel Deck (Min. 22 Gauge) with VapAir Seal 725TR and Cav-Grip Primer
Min. 1/2" DensDeck Prime or
7/16" OSB over Polyiso
16 (2 sq. ft.)6" ribbons of FAST 1-90----
Securock
HP-H
Concrete Deck
Min. 1/2" Polyiso HP-H 12" ribbons of FAST7/16" OSB12" ribbons of FAST 1-315----
12" ribbons of 12" ribbons of
Min. 1/2" Polyiso HP-H 7/16" OSB1-240----
Olybond 500 BAOlybond 500 BA
Concrete Deck with VapAir Seal 725TR/Cav-Grip Primer, 702 LV Primer or 702 Primer
1-255
----
Cav-Grip
1-195
Min. 1/2" Polyiso HP-H 12" ribbons of FAST7/16" OSB12" ribbons of FAST
----
702 LV
1-90
----
702
Steel Deck (Min. 22 Gauge)/VapAir Seal 725TR with Cav-Grip Concrete Deck/SureMB 90TG or 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" DensDeck Prime or
7/16" OSB over Polyiso
16 (2 sq. ft.)6" ribbons of FAST 1-90----
Securock
HP-H
Concrete Deck with SureMB 90TG and 120TG Base Torch Applied/Cut-Back Asphalt Primer
Min. 1/2" Polyiso HP-H 12" ribbons of FAST7/16" OSB12" ribbons of FAST 1-330----
Tectum Deck
Min. 1-1/2" Polyiso HP-H Full-Coverage FAST7/16" OSBFull-Coverage FAST1-150----
12" ribbons of 12" ribbons of
Min. 1-1/2" Polyiso HP-H 7/16" OSB1-90----
Olybond 500 BAOlybond 500 BA
Gypsum Deck Tear-Off
Min. 1-1/2" Polyiso HP-H Full-Coverage FAST7/16" OSBFull-Coverage FAST1-90---
12" ribbons of 12" ribbons of
Min. 1-1/2" Polyiso HP-H 7/16" OSB1-90---
Olybond 500 BAOlybond 500 BA
(Celcore) Cellular Lightweight Insulating Concrete Over Steel Decking
FM Approved Loose laid7/16" OSB17 (1.9 sq. ft)1-105----
(Celcore) Cellular Lightweight Insulating Concrete Over Concrete Decking
Min. 1/2" Polyiso HP-H 4" ribbons of FAST7/16" OSB4" ribbons of FAST 1-135----
<< TABLE OF CONTENTS
tğŭĻ ЍЎ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
OSB Ratings - Recover
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-Tough
Base Layer FasteningTop Layer Fastening
Sure-ToughSure-White
Base Insulation LayerTop Insulation
NonreinforcedFR
(mechanically fastened (mechanically fastened see notes Rating
(Max. thickness 36")Layer
see notes 38, 39 & 40)38, 39 & 40)
RoofNAV Number
Steel Deck (Min. 22-Gauge)
FM Approved Loose laid7/16" OSB17 (1.8 sq. ft)1-105----
Concrete Deck
Min. 1/2" Polyiso HP-H 12" ribbons of FAST7/16" OSB12" ribbons of FAST 1-90----
<< TABLE OF CONTENTS
tğŭĻ ЍЏ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
FM Approvals
Design "A" Adhered Roofing Systems
Lightweight Insulating Concrete - New Construction
Sure-Seal FR Nonreinforced .045', .060" or .090"
Sure-Tough .045", .060", or .075"
Membrane Type:
Sure-Tough FR .045', .060" or .075"
Sure-White .060" or .090"
Sure-Seal 90-8-30A (90-8-30A) or EPDM x-23 LVOC Bonding Adhesive (LVOC)
Membrane Adhesive:
FAST = FAST 100LV, Flexible FAST, FAST Bag in a Box, FAST Dual Cartridge and FAST Dual Tank
Base and Top Layer
(FAST Dual Tank can only be used on Steel and Concrete Decking)
Adhesive:
Sure-Seal FR Sure-ToughSure-Tough FRSure-White
Lightweight Insulating
Nonreinforced
Deck TypeRating
Concrete
RoofNAV Number
Steel Celcore 1-135----
ConcreteCelcore 1-270----
173454-0-50936173568-0-50936 173566-0-50936192446-0-50936
ConcreteElastizell1-180
(90-8-30A)(90-8-30A)(90-8-30A)(90-8-30A)
<< TABLE OF CONTENTS
ЍА ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Sure-Seal/Sure-White Adhered Roofing Systems
1-165 (165 psf) Wind Uplift Equivalency Ratings (over OSB)
Membrane Type: Sure-Seal/Sure-White .060" Non-Reinforced EPDM Membrane
Wind uplift testing has been completed in accordance with the FM Approvals 4470 Test Procedure which was witnessed and certified by Architectural Testing, Incorporated, an industry
recognized Independent Testing Laboratory. Over a 22-gauge steel roof deck, the following results were obtained. Performance Test Reports are on file and available from Carlisle.
165 psf Uplift Resistance (1-165 Approval Equivalency on 12' X 24' Table) (43)(44)
InsulationInsulation Fastening Density
Polyisocyanurate insulation overlaid with minimum 7/16" thick APA grade non-17 fasteners per 4' X 8' board per
veneer oriented strand board (OSB).Carlisle Detail A-27-D
<< TABLE OF CONTENTS
ЍБ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
NATIONAL, STATE & CITY BUILDING CODE APPROVALS
AuthorityApprovalApproved Systems
Report ESR 1184"B"
ICC - International Code Council
Report ESR-1463
SBCCI "B"
BOCA"B"
These Code Bodies merged to form
ICC as of March 2003
"B"
Refer to ICC approval
"B"
ICBO
State of Florida Evaluation Report
Evaluation Report Use
Evaluation Report Number
Not for use in High Velocity Hurricane Zone area
FL1601
For use in High Velocity Hurricane Zone area
FL16441
<< TABLE OF CONTENTS
Carlisle SynTec, a division of Carlisle Construction Materials Incorporated, P. O. Box 7000, Carlisle, PA 17013
(800)-4SYNTEC (800-479-6832)
Carlisle Sure-Seal FR Nonreinforced, Sure-White, Sure-Tough, Sure-Tough FR, FAST and RUSS are Trademarks of Carlisle Construction Materials Incorporated.
DensDeck Prime is a Trademark of Georgia-Pacific
The contents of this issue represents the applicable information available at the time of publication. The contents of older issues are no longer accurate due to subsequent changes.
Printed in USA - 85-5-203
2016 Copyright Carlisle Construction Materials Incorporated
ЍВ ƚŅ ЎЊ
600526 - EPDM Codes 10/2016
Sure-Seal EPDM
Reference Notes
(Page 1 of 2)
1. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table)
2. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table)
or SecurShield HD Composite. (return to table)
Composite. (return to table)
(return to table)
(return to table)
7. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table)
(return to table)
9. Any UL Classified insulation, any combination, any thickness, may be used below the SecurShield CD. (return to table)
10. For insulation requirements, maximum roof slopes and acceptable roof construction types (new, Tear-off or retrofit), click here.(return to table)
11. Testing conducted on FM approved 22-gauge Grade E steel decking meeting ASTM A653 or A446 Grade 80. (return to table)
12. Please reference ANSI-SPRI WD-1/ASCE 7-10 for non-FM insured projects, click here. (return to table)
13. Steel decking shall be FM approved minimum 22-gauge meeting ASTM designation A611 Grade E or A653 Grade 80. (return to table)
14. Testing conducted on standard FM approved 22-gauge steel decking secured as outlined in the FM Approval Guide and FM Loss Prevention
Data Sheet 1-29. (return to table)
15. For FM 1-90 ratings, deck securement requirements are outlined in the FM Approval Guide under the respective deck manufacturer approval listing. (return to table)
16. Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types
(new, Tear-off or retrofit), click here. (return to table)
17. On steel decks, a thermal barrier of FM approved perlite or gypsum board (Type "X" or Type "C") is required under expanded and extruded polystyrene insulations.
For specific thermal barrier requirements, consult the respective insulation manufacturer or current published FM Approval Guide. (return to table)
18. On FM approved wood decks, minimum 1/4" thick gypsum board must be installed beneath the insulations listed. Polystyrene insulations must incorporate 1/4" gypsum
board in addition to standard thermal barrier requirements. (return to table)
19. Existing roof must be FM Class 1 rated. (return to table)
20. Testing conducted on minimum 22-gauge steel roof deck secured to the structural steel supports having a maximum span of 6' on center. The deck is fastened to the
minimum 1/4" thick steel supports with ITW Buildex Traxx/5 fasteners spaced a maximum of 6" on center. Deck side laps are secured with Traxx/1 Fasteners spaced
a maximum of 30" on center. (return to table)
21. 1/2" thick HP Recovery Board cannot be installed as a single layer directly over wide rib (type B) or intermediate rib (type F) steel decks. For flute spanability criteria with
Polyisocyanurate insulation, contact the respective insulation manufacturer. (return to table)
22. Refer to the following pages for insulation requirements, maximum roof slopes and acceptable roof construction types (new, Tear-off or retrofit), click here. (return to table)
23. Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types
(new, Tear-off or retrofit), click here. (return to table)
24. Ballast to be nominal 1-1/2" diameter, river washed stone at a minimum 10 pounds per square foot. Individual concrete pavers (minimum 18 pounds per square foot) or
approved lightweight interlocking pavers (minimum 10 pounds per square foot) may also be used. 1/8" maximum spacing between pavers is permitted. (return to table)
25. Carlisle HP Protective Mat may be used between the ballast and the membrane without altering the rating. (return to table)
26. Ballast to be nominal 1-1/2" diameter, river washed stone at a minimum 10 pounds per square foot. Individual concrete pavers (minimum 18 pounds per square foot) or
approved lightweight interlocking pavers (minimum 10 pounds per square foot) may also be used. 1/8" maximum spacing between pavers is permitted. (return to table)
27. Carlisle HP Protective Mat must be used between the ballast and the extruded polystyrene insulation. (return to table)
28. Insulation products listed are for use above the EPDM membrane. One layer of any UL classified insulation may be added below the membrane without altering
the rating. (return to table)
600526 - EPDM Codes50 of 51 10/2016
Reference Notes
(Page 2 of 2)
29. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table)
30. Any roof covering system listed for use over a combustible roof deck can be installed over a non-combustible roof deck and achieve the same classification. (return to table)
or SecurShield HD Composite. (return to table)
Composite. (return to table)
(return to table)
(return to table)
35. All insulation joints must be staggered a minimum of 6 inches from the deck joints or from the insulation joints directly below. (return to table)
(return to table)
37. Any UL Classified insulation, any combination, any thickness, may be used below the SecurShield CD. (return to table)
38. Sure-Seal HP fastener/Sure-Seal Insulation plate.
Click on one of the following to return to chart: SecurShield HD,
39. InsulFAST fastener/Sure-Seal Insulation plate.
SecurShield HD Plus, Polyiso HP-H, SecurShield, SecurShield HD
Composite,Securock, DensDeck Prime, OSB or HP Recovery Board
40. InsulFAST fastener/SecurFAST Insulation Fastening plate.
41. 80 ksi with one fastener per attachment point. (return to table)
42. 80 ksi with two fasteners per attachment point. (return to table: SecurShield HD Plus, DensDeck Prime or SecurShield)
43. Testing conducted on 22-gauge steel roof deck secured to the strucural steel supports having a maximum span of 6" on center. The deck is fastened to the minimum 1/4" thick steel
supports
with ITW Buildex Traxx/5 fasteners spaced a maximum of 6" on center. Deck side laps are secured with Traxx/1 Fasteners spaced a maximum of 30" on center. (return to table)
44. Failure occurred upon pressurization at 180 psf. System passed 165 psf resistance cycle. (return to table)
<< TABLE OF CONTENTS
600526 - EPDM Codes51 of 51 10/2016
FYQFSJFODF!UIF!DBSMJTMF!EJGGFSFODF
Uzqjdbm!Bqqmjdbujpot
Tvsf.Tfbm!Nfncsbof!xjui!
2
Gbdupsz.Bqqmjfe!Ubqf!)GBU*
3
3
Dbsmjtmf!Cpoejoh!Beiftjwf
2
4
Dbsmjtmf!Gbtufofst!boe!Qmbuft
4
Bddfqubcmf!Jotvmbujpo
5
5
6
6 Bqqspwfe!Sppg!Efdl
Tztufn!Gfbuvsft!'!CfofÑ!ut;
¼!61!zfbst!pg!qspwfo!qfsgpsnbodf
¼!Jo!dpmefs!dmjnbuft-!ebsl.dpmpsfe!FQEN!sfevdft!ifbujoh!
Tvsf.Tfbm!FQEN!Nfncsboft!gps!gvmmz!beifsfe!
dptut-!xijdi!bsf!hfofsbmmz!46!ujnft!hsfbufs!uibo!
sppÑ!oh!tztufnt!bsf!bwbjmbcmf!jo!uif!gpmmpxjoh;
dppmjoh!dptut
Dpmps
Cmbdl
¼!Joevtusz!mfbejoh!VW!sftjtubodf!pg!52-691!lK0n³
Uijdlofttft!)njmt*56-!71!boe!:1
¼!Gvmm!uijdloftt!pg!xfbuifsjoh!nbufsjbm-!op!joufsobm!tdsjn
Tuboebse!Xjeuit
21(!41(
¼!576&!fmpohbujpo!sftvmut!jo!tvqfsjps!ibjm!ebnbhf!
Tuboebse!Mfohuit 61(211(
sftjtubodf
¼!Mpxftu!hmpcbm!xbsnjoh!qpufoujbm-!bdje!sbjo!boe!tnph!
jnqbdu!bddpsejoh!up!FQBt!USBDJ!npefm
Ofx!DpotusvdujpoSf.sppÑ!oh
Hzqtvn!'Tnppui!Hsbwfm!
Qmzxppe!Mu/!Xu/!TusvduvsbmXppe!Fyjtujoh!
Fyjtujoh!ps!Ofx!Efdl!UzqfTuffmGjcspvt!Tvsgbdf!Tvsgbdfe!
ps!PTCDpodsfufDpodsfufQmboltTjohmf.Qmz
DfnfouCVSCVS
+Sfgfs!up!
Jotvmbujpo!Sfrvjsfe ZftOpOpZftZftOpZftZft
Tqfdt
Sfdpnnfoefe!Jotvmbujpot
Dbsmjtmf!Qpmzjtp-!PTC!ps!TfdvsTijfme!IE!Dpwfs!Cpbse!pwfs!QpmztuzsfofSfgfs!up!Ofx!Dpotusvdujpo
Jotvmbujpo!Buubdife!Cz GBTU!Beiftjwf!)opo.qfofusbujoh*!ps!Dbsmjtmf!Gbtufofst!boe!QmbuftSfgfs!up!Ofx!Dpotusvdujpo
Nfncsbof!Buubdife!Cz Dbsmjtmf.Bqqspwfe!Cpoejoh!BeiftjwfSfgfs!up!Ofx!Dpotusvdujpo
GPS!UFBS!PGG!PQUJPOT!SFGFS!UP!OFX!DPOTUSVDUJPO!BCPWF/!
911.58:.7943!}!Q/P/!Cpy!8111!!}!!Dbsmjtmf-!QB!28124!!}!!Gby;!828.356.8164!!}!!xxx/dbsmjtmftzoufd/dpn
FYQFSJFODF!UIF!DBSMJTMF!EJGGFSFODF
JotubmmbujpoTztufn!Dpeft
¼!VM!Dmbtt!B!boe!C!sbujoht!bsf!bwbjmbcmf!pwfs!nptu!efdl!uzqft
Tvsf.Tfbm!opo.sfjogpsdfe!ps!56.-!71.!boe!86.njm!Tvsf.Upvhi!sfjogpsdfe!
¼!GN!vqmjgu!sbujoht!vq!up!2.231!bsf!bwbjmbcmf
nfncsboft/
Jotvmbujpo!jt!fjuifs!nfdibojdbmmz!gbtufofe!up!uif!sppg!efdl!fwfsz!uxp!trvbsf!
gffu-!beifsfe!xjui!GBTU!Beiftjwf!ps!puifs!Dbsmjtmf!bqqspwfe!jotvmbujpo!
Rvbmjuz!Bttvsbodf
beiftjwf/!Nfncsbof!jt!beifsfe!up!uif!jotvmbujpo!xjui!Dbsmjtmf!Bqqspwfe!
Dbsmjtmf!Bvuipsj{fe!Bqqmjdbupst!ibwf!cffo!usbjofe!up!jotubmm!gvmmz!beifsfe!
Cpoejoh!Beiftjwf/!Bekpjojoh!tiffut!pg!FQEN!bsf!tqmjdfe!uphfuifs!b!
njojnvn!pg!4#!vtjoh!Dbsmjtmft!TfdvsUBQF!ps!GBU!tfbn!ufdiopmphz/
Jotqfdujpo
Vqpo!jotubmmbujpo!dpnqmfujpo-!boe!qsjps!up!uif!jttvbodf!pg!b!nfncsbof!
dpnqmfuf!jogpsnbujpo/
tztufn!xbsssbouz-!bo!jotqfdujpo!xjmm!cf!dpoevdufe!cz!b!Dbsmjtmf!Ufdiojdbm!
Sfqsftfoubujwf/
Nfncsbof!boe!Tztufn!Tusfohuit
¼!Dbsmjtmf!nbovgbduvsft!bmm!nbkps!dpnqpofout!pg!uif!sppg!tztufn
Xbssbouz
¼!Ejnfotjpobmmz!tubcmf!jo!cpui!ipu!boe!dpme!dmjnbuft
Dpotvmu!zpvs!Bvuipsj{fe!Bqqmjdbups!ps!Dbsmjtmf!Nbovgbduvsfst!
¼!Op!tmpqf!sftusjdujpot
Sfqsftfoubujwf0Ejtusjcvups!gps!bttpdjbufe!xbssbouz!dibshft/
¼!Mjhiuxfjhiu!bttfncmz!gps!b!wbsjfuz!pg!efdlt
Uijt!tztufn!qspqfsmz!jotubmmfe!boe!jotqfdufe!po!b!dpnnfsdjbm!qspkfdu
nbz!sfdfjwf;
¼!Sfevdft!dbscpo!gppuqsjou!cz!mpxfsjoh!ifbujoh!dptut
¼!B!21.-!26.-!31.-!36.!ps!41.zfbs!)86.njm!ps!:1.njm!sfrvjsfe*!Hpmefo!
¼!Sfevdft!tbgfuz!ib{bse!gspn!topx!boe!jdf!bddvnvmbujpo
Tfbm!Upubm!Tztufn!Xbssbouz!nbz!cf!sfrvftufe!xifo!bmm!nbufsjbmt!
¼!Sfevdft!ib{bsepvt!sppgupq!dpoejujpot!gspn!gsptu-!efx-!ps!jdf!uibu!
Dbsmjtmf/!B!nbyjnvn!qfbl!hvtu!xjoe!tqffe!dpwfsbhf!pg!66!njmft!
¼!Sfevdft!qpufoujbm!dpoefotbujpo!qspcmfnt!uibu!dbo!fspef!tztufn!
qfs!ipvs!jt!tuboebse/!Beejujpobm!dpwfsbhf!vq!up!41!zfbst!boe!231!
qfsgpsnbodf
nqi!jt!bwbjmbcmf/
¼!
¼!B!2#!ibjm!xbssbouz!jt!bwbjmbcmf!xjui!71.njm!FQEN!boe!b!3#!ibjm!
xbssbouz!jt!bwbjmbcmf!xjui!86.njm!ps!:1.njm!FQEN
¼!GBU!Tfbn!Ufdiopmphz!boe!Qsfttvsf.Tfotjujwf!Gmbtijoh!bddfttpsjft!
¼!B!51.zfbs!opo.qspsbufe!FMJUF!nfncsbof!nbufsjbm!xbssbouz!jt!
foibodf!xpslnbotijq!rvbmjuz
bwbjmbcmf!xjui!:1.njm!cmbdl!FQEN
¼!56.njm-!71.njm!boe!:1.njm!Tvsf.Tfbm!nfncsboft!bwbjmbcmf!gps!26.-!
36.!boe!41.zfbs!tztufn!xbssboujft
¼!Xbssbouz!gps!tztufnt!jodpsqpsbujoh!Dbsmjtmft!Tvsf.Upvhi!nfncsbof!
jodmvef!dpwfsbhf!gps!ebnbhf!dbvtfe!cz!bddjefoubm!qvoduvsft
¼!Bwbjmbcmf!jo!21(-!27¾(-!31(-!36(!boe!41(!xjeuit/!Uiftf!xjeuit!pg!
opo.sfjogpsdfe!Tvsf.Tfbm!nfncsbof!sfevdf!tqmjdft!cfuxffo!tiffut
/
¼!Vtjoh!Tvsf.Upvhi!sfjogpsdfe!nfncsbof!jodsfbtft!qvoduvsf!
¼!
tuffqmz!tmpqfe!sppg!eftjhot
¼!\[fsp!)op!hspxui*!sbujoh!gps!gvohbm!hspxui
911.58:.7943!}!Q/P/!Cpy!8111!}!!Dbsmjtmf-!QB!28124!!}!!Gby;!828.356.8164!!}!!xxx/dbsmjtmftzoufd/dpn
23/22/26!ª!3126!Dbsmjtmf/Dbsmjtmf-!Tvsf.Tfbm-!Tvsf.Upvhi-!Tvsf.Xijuf-!TfdvsUBQF-!Hpmefo!Tfbm-!GBTU-!GBU!boe!Gbdupsz.Bqqmjfe!Ubqf!bsf!usbefnbslt!pg!Dbsmjtmf/
SFQSJOU!DPEF;!711596!.!Tvsf.Tfbm!FQEN!Gvmmz!Beifsfe!Tztufn!Tiffu
GVMMZ!BEIFSFE!SPPGJOH!TZTUFN
JOTUBMMBUJPO!JOTUSVDUJPOT
Q/P/!Cpy!362!Qmbjogjfme-!QB!28192
UFM;!977/582/6236!GBY;!828/:71/5145
HFOFSBM!JOGPSNBUJPO
Uijt!Sppgupq!Hvjef!ibt!cffo!eftjhofe!up!hjwf!uif!vtfs!b!HFOFSBM!pwfswjfx!pg!uif!
¯
bqqmjdbujpo!pg!b!XfbuifsCpoe!SCS!gvmmz!beifsfe!FQEN!sppg/!Uijt!Sppgupq!Hvjef!jt!
joufoefe!bt!b!cspbe!sfgfsfodf!bje-!boe!jt!opu!joufoefe!up!cf!bmm.jodmvtjwf/!Qmfbtf!
QSFDBVUJPOT
Jg!uif!beiftjwf!jt!opu!bmmpxfe!up!esz!qspqfsmz-!hbt!cvccmft!ps!cmjtufst!nbz!gpsn!
voefs!uif!nfncsbof!tiffu/!Uiftf!cvccmft!ps!cmjtufst!nbz!tvctjef!pwfs!ujnf/!
xifo!uif!bncjfou!ufnqfsbuvsf!jt!ofbs!uif!efx!qpjou/!Jg!dpoefotbujpo!efwfmpqt-!
qpttjcmf!tvsgbdf!dpoubnjobujpo!nbz!pddvs-!boe!uif!bqqmjdbujpo!pg!beiftjwf!
nvtu!cf!ejtdpoujovfe/!Bmmpx!uif!tvsgbdf!up!esz-!boe!xifo!dpoejujpot!bmmpx-!bqqmz!
b!uijo!dpbu!bu!b!dpwfsbhf!sbuf!pg!bqqspyjnbufmz!ibmg!uif!opsnbm!dpwfsbhf!sbuf!gps!
sf.beifsjoh!b!qsfwjpvtmz!dpbufe!tvsgbdf/!
Vtf!fyusfnf!dbsf!xifo!xpsljoh!po!mbeefst-!sppgt-!cfmpx.hsbef!bqqmjdbujpot!
dpnqmjbodf!xjui!ufsnt!boe!mjnjubujpot!pg!uif!xbssbouz/!
Tvsgbdf!nbz!cf!tmjqqfsz!xifo!xfu-!ebnq!ps!gsptu.dpwfsfe/!Ep!opu!tusfudi!uif!
qspevdu!evsjoh!jotubmmbujpo/!Ep!opu!fyqptf!qspevdu!up!ufnqfsbuvsft!jo!fydftt!
boujdjqbufe/
UIJT!JOGPSNBUJPO-!BT!XFMM!BT!JOGPSNBUJPO!DPOUBJOFE!JO!NBUFSJBM!
TBGFUZ!EBUB!TIFFUT!BOE!PO!QSPEVDU!QBDLBHJOH-!NVTU!CF!SFWJFXFE!
QSJPS!UP!TUPSBHF-!IBOEMJOH!PS!VTF!PG!UIFTF!QSPEVDUT/
2
QSFDBVUJPOT
Mjrvje!beiftjwft-!qsjnfst-!boe!tfbmbout-!bt!xfmm!bt!uifjs!gvnft-!dpoubjo!
qfuspmfvn!ejtujmmbuft!boe!bsf!FYUSFNFMZ!GMBNNBCMF/!Ep!opu!joibmf!wbqpst/!
xifo!uiftf!qspevdut!bsf!vtfe/
Lffq!dpoubjofst!dmptfe!xifo!opu!jo!vtf/!Nblf!tvsf!uibu!pqfo!dpoubjofst!bsf!opu!
qmbdfe!ofbs!gsfti!bjs!wfoujmbupst!po!uif!sppg/!Bwpje!dpoubdu!xjui!fzft/!Hmbttft-!
jnnfejbufmz!xjui!qmfouz!pg!xbufs!gps!b!njojnvn!pg!26!njovuft-!boe!dpoubdu!b!
qiztjdjbo/!Bwpje!dpoubdu!xjui!uif!tljo/!Difnjdbmmz!sftjtubou!hmpwft!bsf!sfrvjsfe!gps!
iboe!qspufdujpo/!Jo!dbtf!pg!tljo!dpoubdu-!uipspvhimz!xbti!uif!bggfdufe!bsfb!xjui!
tpbq!boe!xbufs/!
Xifo!mpbejoh!nbufsjbmt!poup!uif!sppg-!nblf!tvsf!uibu!dpodfousbufe!mpbet!ep!opu!
fydffe!uif!eftjho!mpbe!mjnjubujpot!pg!uif!fyjtujohsppg!tusvduvsf/!Jg!tubdljoh!qspevdut-!
Up!fotvsf!qspqfs!beiftjpo-!dmfbo!nfncsboft!xjui!Xfbuifsfe!Nfncsbof!Dmfbofs!
qsjps!up!jotubmmbujpo/
3
UPPMT!BOE!FRVJQNFOU
Tpgu!csjtumfTdjttpstEvdu!ubqfGjsf!fyujohvjtifs
qvti!csppn
Dibml!mjof5!boe!:!nfejvn!
Vujmjuz!lojgf
obq!qbjou!spmmfs!boe!
Tuffm!ps!tjmjdpof
Dpbufe!ps!tpmwfou.
Mvncfs!dsbzpo
iboemf
3!iboe!spmmfs
sftjtubou!)Izdspo*!
Dbvml!hvo
hmpwftQbqfs!ipmf!qvodi
Dpuupo!sbht
Tbgfuz!hmbttft
Ibnnfs
SPPG!TVSGBDF!QSFQBSBUJPO
Uif!XfbuifsCpoe!SCS!gvmmz!beifsfe!tztufn!xjmm!beifsf!up!xppe-!nfubm-!qmbtujd-!
cf!bqqmjfe!up!qpmztuzsfof!jotvmbujpo/!Qsjnjoh!pg!uif!sppg!efdl!jt!opu!sfrvjsfe/
Cf!tvsf!uif!sppg!tvsgbdf!jt!dmfbo-!boe!gsff!pg!evtu-!ejsu-!svtu-!pjm-!hsfbtf!boe!mpptf!
nbufsjbm/!Uif!sppg!tvsgbdf!nvtu!cf!esz/!Uijt!qspevdu!xjmm!opu!beifsf!up!xfu!ps!
ebnq!tvsgbdft/!Usbqqfe!npjtuvsf!nbz!wbqpsj{f!boe!ofhbujwfmz!bggfdu!uif!
qfsgpsnbodf!pg!uijt!qspevdu/!
tipvme!ibwf!b!qptjujwf!tmpqf!pg!bu!mfbtu!¾;23!up!qsfwfou!qpoejoh!xbufs/!Qpoejoh!
Cfgpsf!tubsujoh-!qmfbtf!dpotvmu!uif!Qsfdbvujpot!tfdujpo!bu!uif!cfhjoojoh!pg!
uijt!nbovbm/!
Izdspo!jt!b!usbefnbsl!pg!Cfdupo!Ejdljotpo!'!Dpnqboz/
4
)*
JOTUBMMBUJPO!PG!JOTVMBUJPO!PQUJPOBM
Cvuu!bmm!jotvmbujpo!cpbset!uphfuifs-!tubhhfsjoh!uif!kpjout/!Bmm!tqbdft!mbshfs!uibo!
Tdsfxt!boe!efdl!qmbuft!tibmm!cf!bqqmjfe!bu!uif!njojnvn!sbuf!pg!fjhiu!)9*!qfs!
jotvmbujpo!nbovgbduvsfs/!Xifo!jotubmmjoh!jotvmbujpo!bspvoe!uif!qfsjnfufs-!uif!
gbtufojoh!qbuufso!jt!pof!)2*!efdl!qmbuf!boe!pof!)2*!tdsfx!fwfsz!uxp!)3*!trvbsf!
gffu!ps!tjyuffo!)27*!qfs!5!y!9!tiffu!jo!b!ejbnpoe!jo!uif!cpy!qbuufso-!boe!fjhiu!
)9*!qfs!5!y!5!tiffu/
Fyusb!gbtufofst!tipvme!cf!jotubmmfe!bspvoe!qspusvtjpot!tvdi!bt!qjqft-!dijnofzt-!
tlzmjhiut!boe!jssfhvmbsjujft!jo!uif!sppg!efdl/
Ep!opu!mbz!npsf!jotvmbujpo!uibo!dbo!cf!dpwfsfe!xjui!uif!XfbuifsCpoe!SCS!FQEN!
nfncsbof!cz!uif!foe!pg!uif!xpsljoh!ebz/
Qfsjnfufs!GbtufofsGjfme!Gbtufofs
QbuufsoQbuufso
5É5É
9É9É
/5!y!uif!cvjmejoht!ifjhiu/
5
JOTUBMMBUJPO!PG!SPPGJOH
Hfofsbm;
Tujs!beiftjwf!uipspvhimz!cfgpsf!bqqmzjoh!up!tvsgbdf)t*/
Sfgfs!up!uif!tfdujpot!jo!uijt!nbovbm!eftjhobufe!up!qjqft-!qfofusbujpot-!dvsct-!!!
qfsjnfufst!boe!ufsnjobujpot!gps!jotusvdujpot!po!jotubmmjoh!nfncsbof!up!tvsgbdft!
xjui!uiftf!dibsbdufsjtujdt/!
Bekpjojoh!tiffut!NVTU!cf!qptjujpofe!tp!uibu!bo!pwfsiboh!pg!BU!MFBTU!4!gps!cpui!
uif!mfohui!boe!xjeui!pg!uif!sppg!jt!bdijfwfe/!
EP!OPU!bqqmz!cpoejoh!beiftjwf!up!boz!tfbn!bsfbt!)tff!Tfbnt!tfdujpo!pg!
uijt!nbovbm!gps!jotubmmbujpo!jotusvdujpot!po!tfbnjoh!bekpjojoh!tfdujpot!pg!uif!
nfncsbof!uphfuifs*/
Tvctusbuf!Qsfqbsbujpo!)gps!cpui!2.tjefe!boe!3.tjefe!bqqmjdbujpo!nfuipet*;
Cf!tvsf!uibu!tvsgbdf!jt!dmfbo!boe!gsff!pg!boz!ejsu-!evtu-!pjm-!hsfbtf-!svtu!ps!boz!puifs!
mpptf!nbufsjbm!)tff!Sppg!Tvsgbdf!Qsfqbsbujpo!tfdujpo*/!Opuf;!Uif!tvsgbdf!NVTU!cf!
esz!cfgpsf!bqqmzjoh!beiftjwf/!Boz!npjtuvsf!nbz!ofhbujwfmz!bggfdu!uif!qfsgpsnbodf!
pg!uiftf!qspevdut/
Dmfbo!boz!fydfttjwf!ejsu!gspn!uif!nfncsbof!xjui!XfbuifsCpoe!Nfncsbof!
Dmfbofs-!ps!xjqf!ubmd!pgg!xjui!b!csvti!ps!dmfbo!dmpui/!
Vospmm!uif!XfbuifsCpoe!SCS!FQEN!nfncsbof!pwfs!uif!tvctusbuf!tp!uibu!ju!jt!
xsjolmf.gsff-!boe!uif!qsf.nbslfe!mjoft!bsf!gbdf!vq!bu!uif!vqqfs!fehf/!Qptjujpo!
up!bmmpx!gps!qspqfs!ufsnjobujpo!boe!pwfsmbq!pg!bekbdfou!tiffut/
Bmmpx!uif!XfbuifsCpoe!SCS!FQEN!nfncsbof!up!sfmby!gps!uijsuz!)41*!njovuft/
Cfhjoojoh!bu!uif!mpx!fehf!pg!uif!sppg-!dvu!uif!nfncsbof!up!mfohui!)jg!ofdfttbsz*-!
boe!qptjujpo!uif!tiffu!tp!uibu!ju!bdijfwft!bo!pwfsiboh!pg!bu!mfbtu!4!)gps!cpui!
xjeui!boe!mfohui!pg!uif!sppg*/!Vtf!evdu!ubqf!up!tfdvsf!xjeui-!boe!ibmg!uif!mfohui!
joup!qmbdf/
Bwpjejoh!xsjolmft-!gpme!uif!nfncsbof!jo!ibmg!poup!jutfmg-!fyqptjoh!uif!
tvctusbuf!efdl/
Uxp.Tjefe!)Dpoubdu*!Bqqmjdbujpo;
Gps!bqqmjdbujpo!pg!XfbuifsCpoe!FQEN!Nfncsbof!poup!qpspvt!ps!opo.qpspvt!
tvsgbdft!FYDFQU!qpmztuzsfof!jotvmbujpo/!OPUF;!Sfgfs!up!uif!Tvsgbdf!Qsfqbsbujpo!
tfdujpo!jo!uijt!nbovbm!up!fotvsf!uibu!cpui!uif!tvctusbuf!boe!uif!XfbuifsCpoe!
FQEN!nfncsbof!bsf!sfbez!gps!jotubmmbujpo/
6
JOTUBMMBUJPO!PG!SPPGJOH
Pqfo!boe!uipspvhimz!tujs!uif!XfbuifsCpoe!SCS!MD.71!ps!XfbuifsCpoe!SCS!Bdszmjd!
Xbufs.Cbtfe!Cpoejoh!Beiftjwf/!
Vtf!b!nfejvn!obq-!tpmwfou.bddfqujoh!qbjou!spmmfs!up!bqqmz!uif!Cpoejoh!Beiftjwf!
up!cpui!uif!FQEN!Nfncsbof!boe!uif!tvctusbuf!bu!b!sbuf!pg!tjyuz!)71*!trvbsf!gffu!
qfs!hbmmpo/!
Uif!beiftjwf!nvtu!cf!bqqmjfe!up!211&!pg!cpui!tvsgbdft!jo!bo!fwfomz!ejtusjcvufe!
dpbu!xjuipvu!boz!hmpct!ps!qveemft/
Lffq!cpui!tvsgbdft!fyqptfe-!up!bmmpx!uif!beiftjwf!up!esz!voujm!ju!jt!ubdlz!up!uif!
upvdi/!Opuf;!Beiftjwf!tipvme!ibwf!b!ubdlz-!opu!tusjohz!gffm!cfgpsf!zpv!qspdffe!up!
uif!ofyu!tufqt!pg!jotubmmbujpo/
Tubsujoh!gspn!uif!njeemf-!up!bwpje!xsjolmft-!spmm!uif!dpbufe!tiffu!poup!uif!
dpbufe!tvctusbuf/
Jnnfejbufmz!bgufs!cpui!tvsgbdft!ibwf!cffo!beifsfe-!csppn!uif!tvsgbdf!pg!uif!FQEN!
nfncsbof!up!fotvsf!nbyjnvn!dpoubdu/!Opuf;!EP!OPU!bqqmz!bo!fydfttjwf!bnpvou!
pg!qsfttvsf!xijmf!csppnjoh-!bt!uijt!xjmm!dbvtf!uif!nfncsbof!up!xsjolmf/
Sfqfbu!uif!uxp.tjefe!)dpoubdu*!nfuipe!pg!bqqmjdbujpo!gps!uif!puifs!ibmg!pg!uif!FQEN!
nfncsbof/
2.Tjefe!)Xfu!Mbz.Jo*!Bqqmjdbujpo!gps!XfbuifsCpoe!Xbufs.Cbtfe!Beiftjwf;
Dbvujpo;!Uif!pof.tjefe!bqqmjdbujpo!nfuipe!tipvme!opu!cf!vtfe!jg!uifsf!jt!b!sjtl!pg!
ufnqfsbuvsft!gbmmjoh!cfmpx!56±!G!xjuijo!59!ipvst!pg!jotubmmbujpo/
!Gps!bqqmjdbujpo!po!bddfqubcmf!qpspvt!tvctusbuft!jodmvejoh;
26
!Njojnvn!0.uijdl!Qmzxppe
43
8
!Njojnvn!0.uijdl!Psjfoufe!Tusboe!Cpbse
27
!Njojnvn!¾.uijdl!Ijhi!Efotjuz!Gjcfscpbse
¯
!Njojnvn!¾.uijdl!Efot!Efdl!Qsjnf
Xifo!bqqmzjoh!XfbuifsCpoe!SCS!Bdszmjd!Xbufs.Cbtfe!Cpoejoh!Beiftjwf!up!
wfsujdbm!tvsgbdft-!bqqmz!bt!b!uxp.tjefe!)dpoubdu*!beiftjwf/!OPUF;!Sfgfs!up!uif!
Tvsgbdf!Qsfqbsbujpo!tfdujpo!jo!uijt!nbovbm!up!fotvsf!uibu!cpui!uif!tvctusbuf!boe!
uif!XfbuifsCpoe!FQEN!nfncsbof!bsf!sfbez!gps!jotubmmbujpo/
Pqfo!boe!uipspvhimz!tujs!uif!XfbuifsCpoe!SCS!Bdszmjd!Xbufs.Cbtfe!
Cpoejoh!Beiftjwf/
Efot!Efdl!jt!b!usbefnbsl!pg!H.Q!Hzqtvn!Dpsqpsbujpo/
7
JOTUBMMBUJPO!PG!SPPGJOH
Tubsu!bu!uif!gpme!pg!uif!nfncsbof/!Vtjoh!b!nfejvn!obq!qbjou!spmmfs-!tqsbzfs!ps!!
trvffhff-!bqqmz!21!up!23!njmt!pg!beiftjwf!up!uif!tvctusbuf!POMZ!bu!b!sbuf!pg!
211!up!231!trvbsf!gffu!qfs!hbmmpo!)efqfoejoh!po!kpc!dpoejujpot!boe!qpsptjuz!
pg!tvctusbuf*/
JNNFEJBUFMZ!mbz!uif!nfncsbof!joup!uif!TUJMM!XFU!beiftjwf!up!fotvsf!uibu!
uif!bqqspqsjbuf!bnpvou!pg!beiftjwf!usbotgfst!poup!uif!nfncsbof!tvsgbdf/!
OPUF;!Xfu!beiftjwf!xjmm!cf!xijuf!jo!dpmps<!jg!uif!beiftjwf!ibt!uvsofe!usbotqbsfou-!
bqqmz!b!uijo!dpbu!pg!beiftjwf!up!uif!nfncsbof-!boe!qspdffe!cz!vtjoh!uif!
uxp.tjefe!dpoubdu!bqqmjdbujpo!nfuipe/
Nbujoh!uif!nfncsbof!xjui!uif!xfu!beiftjwf!xjmm!bmmpx!gps!tpnf!nfncsbof!
sfqptjujpojoh!cfgpsf!uif!beiftjwf!tfut/!
Podf!ibmg!pg!uif!tiffu!jt!jo!qmbdf-!vtf!b!qvti!csppn!ps!spmmfs!up!hp!pwfs!uif!
tvsgbdf/!Lffqjoh!tufbez!qsfttvsf!xjui!uif!spmmfs!ps!csppn!bhbjotu!uif!nfncsbof!
xjmm!fmjnjobuf!uif!gpsnbujpo!pg!bjs!cvccmft/
Sfnpwf!boz!xsjolmft!cz!sfqptjujpojoh!uif!tiffu!xjui!b!qvti!csppn-!spmmfs-!
ps!cz!iboe!)jg!qpttjcmf*/
Sfqfbu!uif!bqqmjdbujpo!qspdfevsf!gps!uif!tfdpoe!ibmg!pg!uif!nfncsbof/
QJQFT0QFOFUSBUJPOT
gpmefe!nfncsbof!up!uif!qjqf/!Cf!tvsf!up!nbjoubjo!uif!qspqfs!bmjhonfou!pg!uif!
tiffu!xjui!uif!sppg!fehf-!xbmm!boe!tfbnt/!Nblf!b!tusbjhiu!dvu!gspn!uif!qjqf!up!
Gpme!uif!nfncsbof!cbdl-!boe!cfhjo!uif!cpoejoh!qspdfevsf/
uif!qjqf!up!uif!foe!pg!uif!tiffu/!Bqqmz!mbq!tfbmbou!bspvoe!foujsf!Dpwfstusjq/!Tff!uif!
uijt!efubjm/
DVSCT!)Tlzmjhiut-!Dijnofz*
Xifo!fodpvoufsjoh!bo!pvutjef!dpsofs!po!b!qfsjnfufs!xbmm-!sfgfs!up!uif!Qfsjnfufs!
Xbmm!efubjmt!jo!uijt!nbovbm/!Xifo!fodpvoufsjoh!pvutjef!dpsofst!po!b!sppgupq!
qfofusbujpo!tvdi!bt!b!tlzmjhiu!ps!dijnofz-!gpmmpx!jotusvdujpot!po!uif!ofyu!qbhf/
8
JOTUBMMBUJPO!PG!SPPGJOH
Qsjps!up!bqqmzjoh!uif!beiftjwf-!boe!xijmf!nbjoubjojoh!qspqfs!tiffu!bmjhonfou!xjui!
xbmmt-!qfsjnfufs!fehft!boe!puifs!qspusvtjpot-!vospmm!uif!nfncsbof!vq!up!uif!cbtf!
pg!uif!voju/
Nfbtvsf!uif!xjeui!boe!efqui!pg!uif!voju-!boe!usbotgfs!uif!dpssftqpoejoh!ejnfotjpot!
poup!uif!gpmefe!nfncsbof/!Esbx!bo!Y!jotjef!uif!cpy/!Dvu!uif!Y!nbsl-!boe!gspn!pof!
dpsofs-!dvu!b!tusbjhiu!mjof!up!uif!ofbsftu!fehf!pg!uif!nfncsbof/!Spmm!uif!nfncsbof!
bspvoe!uif!voju-!mfbwjoh!b!usjbohmf!pg!nfncsbof-!boe!uvso!vq!fbdi!pof!pg!uif!gpvs!
)5*!tjeft/!Vtjoh!b!tuboebse!qbqfs!qvodi!ps!tdjttpst-!qvodi!ps!dvu!b!spvoe!ipmf!bu!
fwfsz!bohmf!dibohf!pg!uif!nfncsbof!bu!uif!pvutjef!dpsofst/!)Uijt!xjmm!qsfwfou!uif!
dvu!jo!uif!nfncsbof!gspn!fyqboejoh/*
Bgufs!bmm!dvut!bsf!nbef-!boe!uif!nfncsbof!jt!dpssfdumz!qptjujpofe-!gpme!uif!
cpoe!uif!usjbohmft!vq!uif!tjeft!pg!uif!voju!)j/f/!dijnofz-!tlzmjhiu!fud/*/!Ublf!dbsf!
up!cpoe!uif!nfncsbof!joup!uif!bohmf!dibohf!tp!uibu!uif!nfncsbof!jt!dpnqmfufmz!
tiffu!gspn!uif!dvsc!up!uif!foe!pg!uif!tiffu/!Bqqmz!mbq!tfbmbou!bspvoe!uif!foujsf!
Dpwfstusjq/!Sfgfs!up!uif!Pvutjef!Dpsofst!tfdujpo!pg!uijt!nbovbm!gps!gvsuifs!efubjmt!
QFSJNFUFS!XBMMT
Uif!nfncsbof!po!uif!xbmm!tipvme!cf!b!dpoujovbujpo!pg!uif!efdl!nfncsbof/!Uif!
nfncsbof!tipvme!fyufoe!vq!uif!xbmm!bt!gbs!bt!qpttjcmf-!up!qsfwfou!uif!qpttjcjmjuz!
sppg!efdl!b!njojnvn!pg!7!boe!vq!uif!xbmm!b!njojnvn!pg!23/!
Qptjujpo!uif!tiffu!jo!uif!eftjsfe!mpdbujpo-!gpmejoh!cbdl!uif!nbufsjbm!uibu!xjmm!cf!
jotubmmfe!po!uif!xbmm/!Bqqmz!Cpoejoh!Beiftjwf!up!uif!xbmm-!efdl!boe!nfncsbof-!
boe!bmmpx!up!esz/!Spmm!tiffu!up!uif!cbtf!pg!uif!bohmf!dibohf/!Gjsnmz!qsftt!ps!
dsfbtf!uif!tiffu!ujhiumz!joup!uif!bohmf!dibohf/
tiffu!up!uif!xbmm!boe!sppg!efdl/!Sfgfs!up!uif!Pvutjef!Dpsofs!ps!Sppg!Fehf!Efubjmt!
gps!jotusvdujpot!po!ufsnjobujoh!uif!fehf!pg!uif!nfncsbof/
9
MBQ!TFBMBOU
Wfsujdbm!Ufsnjobujpo
XBUFS!DVU.PGG!NBTUJD!
)CZ!PUIFST*
UFSNJOBUJPO!CBS!GBTUFOFS!
buubjofe!boe!uif!nfncsbof!jt!
)CZ!PUIFST*
beifsfe-!efufsnjof!uif!qmbdfnfou!
pg!uif!Ufsnjobujpo!Cbs-!qffm!uif!upq!
UFSNJOBUJPO!CBS!
)CZ!PUIFST*
fehf!pg!uif!nfncsbof!cbdl-!boe!bqqmz!
CPOEJOH!BEIFTJWF
b!cfbe!pg!Xbufs!Dvu.Pgg!Nbtujd!cfuxffo!
uif!nfncsbof!boe!uif!xbmm!ps!dvsc/!
XFBUIFSCPOE«!NFNCSBOF
Jotubmm!uif!Ufsnjobujpo!Cbs!ejsfdumz!pwfs!
uif!nfncsbof!boe!Xbufs!Dvu.Pgg!Nbtujd/!
OPUFT;
2/!Bqqmz!po!ibse-!tnppui!tvsgbdf!pomz<!opu!gps!vtf!
Dmfbo!boz!Xbufs!Dvu.Pgg!Nbtujd!gspn!uif!
!po!xppe/
Ufsnjobujpo!Cbs-!boe!bqqmz!b!cfbe!pg!
3/!Xbufs!dvu.pgg!nbtujd!nvtu!cf!ifme!voefs!dpotubou
!dpnqsfttjpo/
Mbq!Tfbmbou!pwfs!uif!upq!pg!uif!cbs/
4/!Ep!opu!xsbq!dpnqsfttjpo!ufsnjobujpo!bspvoe!
!dpsofst/
5/!Bmmpx!½!)7!nn*!njo/!up!¾!)24!nn*!nby/!
!tqbdjoh!cfuxffo!dpotfdvujwf!mfohuit!pg!!
!ufsnjobujpo!cbs/
TFBNT
TFBNJOH!VTJOH!TFBN!UBQF
Uif!nfncsbof!tipvme!cf!qptjujpofe!tp!uibu!uif!xjeui!pg!uif!tfbn!jt!4/!Jg!b!qsf.
nbslfe!mjof!jt!opu!qsftfou-!sfnpwf!fydftt!dibml!gspn!b!dibml!mjof!cz!tobqqjoh!
uif!mjof!joup!uif!bjs-!boe!uifo!dibml!b!mjof!pof.rvbsufs!)½*!up!pof.ibmg!jodi!)¾*!
gspn!uif!mfbejoh!tfbn!fehf/
Gpme!uif!upq!tiffu!cbdl!up!fyqptf!uif!tfbn!bsfb/!Vtjoh!uif!nfejvn!obq!qbjou!
spmmfs-!bqqmz!uif!XfbuifsCpoe!Nvmujqvsqptf!Qsjnfs!up!uif!tfbn!bsfb-!vtjoh!cbdl.
boe.gpsui!tusplft!xjui!npefsbuf!qsfttvsf!voujm!uif!tfbn!tvsgbdf!buubjot!b!tnppui-!
cmbdl!bqqfbsbodf/!Bqqmz!uif!XfbuifsCpoe!Nvmujqvsqptf!Qsjnfs!qbtu!uif!tfbn!
OPUF;!Jg!uif!FQEN!nfncsbof!jt!dpoubnjobufe!xjui!ejsu-!evtu!ps!efcsjt-!dmfbo!uif!tfbn!bsfb!xjui!Xfbuifsfe!
Nfncsbof!Dmfbofs!cfgpsf!bqqmzjoh!XfbuifsCpoe!Nvmujqvsqptf!Qsjnfs/
:
Vospmm!uif!4.xjef!Tfbn!Ubqf!bmpoh!uif!mfohui!pg!uif!tfbn-!ubqf!tjef!epxo-!
boe!bmjho!uif!Tfbn!Ubqf!)opu!uif!dmfbs!cbdljoh*!bmpoh!uif!dibml!mjof/!Vtjoh!
npefsbuf!qsfttvsf-!tfu!uif!Tfbn!Ubqf!joup!qmbdf!up!bwpje!bjs!fousbqnfou/!Gpme!
uif!upq!nfncsbof!poup!uif!Tfbn!Ubqf!sfmfbtf!qbqfs/!)Jg!uif!Tfbn!Ubqf!epft!opu!
wjtjcmz!fyufoe!cfzpoe!uif!mfbejoh!tfbn!fehf-!uif!nfncsbof!fehf!tipvme!cf!dvu!
cbdl!up!fyqptf!pof!rvbsufs!jodi!)½*!pg!Tfbn!Ubqf/*
TFBNT
Sfbdijoh!voefs!uif!upq!qmz!pg!nfncsbof-!qvmm!uif!sfmfbtf!qbqfs!bxbz!gspn!uif!
Tfbn!Ubqf!bu!b!56±!bohmf!up!uif!tfbn/!Xijmf!sfnpwjoh!uif!qbqfs-!esbx!zpvs!iboe!
bdsptt!uif!tfbn-!gspn!uif!cbdl!up!uif!mfbejoh!fehf/!Uijt!xjmm!qsfwfou!xsjolmft!boe!
uifo!bdsptt!uif!mfohui!pg!uif!tfbn/
OPUF;
tjmjdpof!iboe!spmmfs/!Bqqmz!mbq!tfbmbou!bmpoh!uif!tfbnt!mfbejoh!fehf-!4!jo!fbdi!ejsfdujpo!gspn!xifsf!uif!tfbn!
ubqf!jt!tqmjdfe!uphfuifs/
1/2” CHALK LINE
SEAM TAPE EXPOSED
APPROX. 1/4”
21
U.KPJOUT
B!U.Kpjou!jt!gpsnfe!xifo!uxp!tiffut!pg!nfncsbof!gpsn!b!tfbn!uibu!usbwfmt!voefs!
ps!pwfs!b!uijse!qmz/!Uif!dfoufs!pg!uif!U!jt!xifsf!uif!njeemf!tiffu!foet-!boe!uif!upq!
tiffu!csjehft!pwfs!uif!njeemf!tiffu/!
Vtf!XfbuifsCpoe!7!Qffm.boe.Tujdl!Dvsfe!U.Kpjou!qbudift!ps!XfbuifsCpoe!
7!Qffm.boe.Tujdl!Vodvsfe!Gmbtijoh!up!gpsn!U.Kpjou!qbudift/!U.Kpjou!qbudift!
tipvme!cf!bu!mfbtu!7!Y!7/!Bqqmz!qsjnfs!up!nfncsbof!tvsgbdf!cfgpsf!bqqmzjoh!
U.Kpjou!qbudift/
OPUF;!Bmm!U.Kpjou!Qbudift!tipvme!cf!uipspvhimz!spmmfe!xjui!b!tuffm!ps!tjmjdpof!iboe!spmmfs/
OPUF;!Xifo!bqqmzjoh!U.Kpjou!qbudift!pwfs!71.njm!XfbuifsCpoe!FQEN!nfncsbof-!Mbq!Tfbmbou!jt!sfrvjsfe!
bspvoe!bmm!fehft!pg!uif!qbudi/
22
DPSOFST
JOTJEF!DPSOFST
Uif!nfncsbof!tipvme!fyufoe!vq!uif!xbmm!bt!gbs!bt!qpttjcmf!)7!njo/*/!Dvu!
uif!nfncsbof!bt!tipxo/!Bqqmz!Cpoejoh!Beiftjwf!up!uif!xbmm-!sppg!efdl!boe!
nfncsbof/!Spmm!tiffu!up!uif!cbtf!pg!uif!bohmf!dibohf/!Gjsnmz!qsftt!ps!dsfbtf!
uif!tiffu!ujhiumz!joup!uif!bohmf!dibohf/!Spmm!uif!tiffu!vq!uif!xbmm/!Vtf!b!csjtumf!
gps!jotusvdujpot!po!ufsnjobujoh!uif!fehf!pg!uif!wfsujdbm!nfncsbof/
SFMFBTF!QBQFS
QSJNFS
B
SFMFBTF
CMVF
QBQFS
4Ç!)9 DN*
QPMZ
NJO
GPME!DPSOFS
MFOHUIXJTF!BOE
QSPDFFE!UP!GPME!BHBJO!
BT!TIPXO!JO!TUFQ!C
SFNPWF
IBMG!PG
QMBDF!RVBSUFS!TFDUJPO!POUP!EFDL!XJUI!MPOH!GPMEFE!
SFMFBTF
TJEF!GBDJOH!UIF!XBMM/!SFNPWF!SFNBJOJOH!SFMFBTF!
QBQFS
QBQFS/!QSFTT!GJSNMZ!BOE!QSPDFFE!XJUI!TFDPOE!
RVBSUFS!HPJOH!VQ!UIF!WFSUJDBM!XBMM!CZ!QSFTTJOH!
GJSNMZ!JOUP!DPSOFS/
OPUF;
Xbmm!Gmbtijoht!tipvme!fyufoe!
b!njojnvn!pg!uxfmwf!jodift!
)23*!bcpwf!uif!sppg!efdl/
!BEIFTJWF
MBQ!TFBMBOU
SFNPWF!CMVF!QPMZ!BOE!GPSN!QJH!FBS/
SPMM!XJUI!UXP!JODI!XJEF!TUFFM!PS!TJMJDPOF!IBOE!SPMMEFS/!
BQQMZ!BEIFTJWF!UP!UIF!QJH!FBS!BOE!BEIFSF!UP!UIF!XBMM/
TFBM!BMM!FYQPTFE!FEHFT!BOE!BQQMZ!XJUI!MBQ!TFBMBOU/
23
DPSOFST
PVUTJEF!DPSOFST
Nfbtvsf!boe!dvu!b!qjfdf!pg!nfncsbof!up!xsbq!uif!qfofusbujpo!boe!pwfsmbq!jutfmg!
cz!b!njojnvn!pg!4/!Bmmpx!bu!mfbtu!4!pg!nbufsjbm!up!fyufoe!poup!uif!efdl-!boe!bu!
mfbtu!4!pg!nfncsbof!up!fyufoe!qbtu!uif!usjbohmf!pg!nfncsbof!bmsfbez!beifsfe
up!uif!dvsc/!Nbsl!uif!eftjsfe!ifjhiu!pg!uif!nfncsbof!po!uif!qfofusbujpo/!Uijt!
nbsl!xjmm!tfswf!bt!uif!tubsujoh!qpjou!pg!uif!jotubmmbujpo!pg!uif!nfncsbof!qjfdf/!
Bqqmz!XfbuifsCpoe!MD.71!Cpoejoh!Beiftjwf!up!uif!qfofusbujpo-!sppg!efdl!boe!
Tubsujoh!bu!uif!nbsl-!qsftt!uif!nbufsjbm!joup!qmbdf-!xpsljoh!gspn!uif!upq!pg!uif!
nfncsbof!up!uif!cpuupn!xijmf!xpsljoh!bspvoe!uif!qfofusbujpo/!Uijt!tufq!xjmm!cf!
fbtjfs!jg!b!tfdpoe!qfstpo!ipmet!uif!nfncsbof!bxbz!gspn!uif!qfofusbujpo/!Uif!
nbufsjbm!uibu!xjmm!tqmjdf!poup!uif!efdl!tipvme!gpme!cbdl!bhbjotu!uif!qfofusbujpo/!
uif!sppg!efdl/!EP!OPU!dvu!uif!4!fydftt!uibu!xjmm!cf!beifsfe!up!uif!qfofusbujpo/!
Tubsujoh!xjui!pof!tjef-!dvu!epxo!up!uif!bohmf!dibohf!bu!uif!dpsofs/!Spmm!uif!
nfncsbof!ujhiumz!joup!uif!bohmf!dibohf!boe!poup!uif!sppg!efdl/!Sfqfbu!po!fbdi!
tjef!pg!uif!qfofusbujpo/!Bqqmz!beiftjwf!up!uif!nfncsbof!bu!uif!qfofusbujpo!xifsf!
Sfgfs!up!uif!Wfsujdbm!Ufsnjobujpo!Tfdujpo!bu!Qfsjnfufs!Xbmmt!gps!jotusvdujpot!po!
ufsnjobujoh!uif!fehf!pg!uif!wfsujdbm!nfncsbof/!
24
DPSOFST
Gjojti!uif!pvutjef!dpsofs!xjui!XfbuifsCpoe!Qffm.boe.Tujdl!Jotjef0Pvutjef!Dpsofst/
6
2
CPOEJOH!BEIFTJWF
GJSNMZ!QSFTT
QSFTT!GPMEFE!GMBTIJOH!UJHIUMZ
JOUP!BOHMF!DIBOHF!BOE!GJSNMZ!QSFTT
GMBTIJOH!BHBJOTU!UIF!WFSUJDBM!TVSGBDF/
QSJNFS
3
7
QMBDF!GPMEFE!GMBTIJOH!UJHIUMZ!JOUP!BOHMF!DIBOHF!BOE!
GJSNMZ!QSFTT!GMBTIJOH!POUP!UIF!EFDL!GMBOHF!CZ!QSFTTJOH!
UIF!GMBTIJOH!BHBJOTU!UIF!IPSJ\[POUBM!TVSGBDF/
SFMFBTF!QBQFS!EFMFUFE
8
4
GPME
CMVF!QPMZ
)SFNPWF!CFGPSF!GPMEJOH*
SFNPWF!TFQBSBUPS!TIFFU!PG!CMVF!QPMZ!GJMN!BOE
SPMM!XJUI!B!UXP!JODI!XJEF!TUFFM!IBOE!SPMMFS/
QBZ!QBSUJDVMBS!BUUFOUJPO!UP!UIF!TUFQ!PGGT!BOE
BOHMF!DIBOHF/
5
9
MBQ!TFBMBOU
QMBDF!UIF!JOTJEF!0!PVUTJEF!DPSOFS!BT!
TFBM!BMM!FYQPTFE!FEHFE!XJUI!MBQ!TFBMBOU
TIPXO!BOE!SFNPWF!SFMBTF!QBQFS
25
NPMEFE!QJQF!TFBM
2/!Dvu!uif!qjqf!tfbm!bekbdfou!up!uif!sbjtfe!sjoh!pof!tj{f!tnbmmfs!uibo!uif!qjqf!
ejbnfufs/!EP!OPU!DVU!EJBHPOBMMZ!UISPVHI!UIF!JOEFY!SJOH/
4/!Nbsl!qjqf!bspvoe!uif!upq!pg!uif!qjqf!tfbm/
5/!Qvmm!qjqf!tfbm!vqxbset!po!qjqf-!voujm!nbsl!po!uif!qjqf!jt!wjtjcmf/
6/!Jotubmm!Xbufs!Dvu.Pgg!Nbtujd!cfmpx!uif!nbsl!uibu!joejdbuft!uif!upq!pg!uif!
jotubmmfe!qjqf!tfbm/!
7/!Bqqmz!XfbuifsCpoe!Nvmujqvsqptf!Qsjnfs!up!uif!FQEN!efdl!nfncsbof!jo!uif!
8/!Qvmm!qjqf!tfbm!cbdl!epxo!pwfs!qjqf!boe!joup!qptjujpo/
9/!Sfnpwf!sfmfbtf!qbqfs!gspn!uif!ubqf-!boe!xjui!iboe!qsfttvsf-!qsftt!ubqf!up!
qsjnfe!bsfb/!Spmm!tqmjdf!bsfb!xjui!b!iboe!spmmfs/
:/!Jotubmm!b!tubjomftt!tuffm!vojwfstbm!dmbnqjoh!sjoh!up!uif!upq!pg!uif!qjqf!tfbm!up!
qspwjef!dpotubou!dpnqsfttjpo!pg!uif!Xbufs!Dvu.Pgg!Nbtujd/
21/!Bqqmz!XfbuifsCpoe!7!Qffm.boe.Tujdl!Dvsfe!U.Kpjou!Qbudift!)ps!XfbuifsCpoe!
22/!Bqqmz!Mbq!Tfbmbou!bspvoe!U.Kpjou!Qbudift/
OPUF;!Ufnqfsbuvsf!pg!uif!qjqf!nvtu!opu!fydffe!291±!G/
26
NPMEFE!QJQF!TFBM
4Ç
4Ç
)86!nn*
DFOUFS!U.KPJOU!DPWFST!PWFS
TFBN!FEHF!BU!PWFSMBQ!PG
QJQF!CPPU!GMBOHF
OPUFT;
3/!Qjqf!tfbm!nvtu!ibwf!joubdu!sjc!bu!upq!fehf-!sfhbsemftt!pg!qjqf!ejbnfufs/
QJQF!BOE!QFOFUSBUJPO!GMBTIJOHT
qspdfevsft!cfmpx!vtjoh!uxp!mbzfst!pg!XfbuifsCpoe!Qffm!boe!Tujdl
Vodvsfe!Gmbtijoh/
OPUFT;
GSPUSVTJPO
2/!Sfnpwf!bmm!mfbe!boe!puifs
MBQ!TFBMBOU
3/!Objmfs!sfrvjsfe!bspvoe!bmm!!
SPPG!EFDL
!qjqft!hsfbufs!uibo!29!
!)57!dn*!jo!ejbnfufs/
QFFM!BOE!TUJDL!VODVSFE!GMBTIJOH
XFBUIFSCPOE«
4/!Qffm.boe.Tujdl!Vodvsfe!
NFNCSBOF
MBQ!TFBMBOU
!Gmbtijoh!xsbqqfe!bspvoe!!
!qjqf!tibmm!ibwf!4!)9!dn*!!
!njo/!nfncsbof!tfbn/
203Ç)24!NN*!NJO/
6Ç)9!DN*
2Ç)3/6!DN*!NJO/
NJO/
27
SPPG!FEHF!EFUBJMT
Nfubm!Esjq!Fehf!boe!Esjq!Fehf!up!Hvuufs!Vtjoh!7Ç!Qffm.boe.Tujdl!
Dvsfe!Dpwfstusjq
Jotubmm!nfubm!esjq!fehf!)cz!puifst*!qfs!nbovgbduvsfst!jotusvdujpot/!Bqqmz!
qsjnfs!up!uif!nfubm!esjq!fehf!boe!uif!nfncsbof-!gps!uif!foujsf!mfohui!pg!uif!
esjq!fehf/!Up!fotvsf!qspqfs!beiftjpo-!bqqmz!qsjnfs!up!bo!bsfb!uibu!jt!xjefs
uibo!uif!Dpwfstusjq/!Uif!Dpwfstusjq!tipvme!cf!bqqmjfe!¾!gspn!uif!pvutjef!fehf!
pg!uif!nfubm!esjq!fehf!xijmf!fyufoejoh!poup!uif!efdl!nfncsbof!cz!bu!mfbtu!3/
Xifo!tqmjdjoh!uxp!qjfdft!pg!Qffm.boe.Tujdl!Dvsfe!Dpwfstusjq-!bmmpx!gps!b!njojnvn!
mbq!pg!2/!Bqqmz!U.Kpjou!qbudift!boe!Mbq!Tfbmbou!xifsf!offefe/
QSJNFS!'!7Ç!)26/6!DN*!XJEF!QFFM!BOE!TUJDL!DVSFE!DPWFSTUJQ
OPUFT;
2/!Njo/!3!)6!dn*!tfbn!gspn!
CPOEJOH!BEIFTJWF
XFBUIFSCPOE«
!objm!ifbe/
FEQN!NFNCSBOF
3/!Qffm.boe.Tujdl!Dpwfstusjq!nvtu!!
3Ç)6!DN*
NJO/
!pwfsmbq!efdl!nfncsbof!njo/!
SPPG!EFDL
!3!)6!dn*/
4/!Gbtufofst!boe!gbtufofs!qbuufso!
!bt!sfdpnnfoefe!cz!nfubm!
!fehf!nbovgbduvsfs/
5/!Xppe!objmfs!nvtu!fyufoe
!qbtu!upubm!xjeui!pg!nfubm!fehf!!!
XPPE!OBJMFS!)CZ!PUIFST*
!cf!tfbmfe!bu!bmm!kpjout/!Dpotvmu!!
!sftqfdujwf!nbovgbduvsfs!gps!
HVUUFS)CZ!PUIFST*
!bqqspqsjbuf!tfbmbou/
Ufsnjobujpo!Cbs!up!Hvuufs
OPUFT;
NJOJNVN)209Ç!y!2Ç*!)/4!y!3/6!DN*!UFSNJOBUJPO
CBS!GBTUFOFE!23Ç!)42!DN*!PO!DFOUFS!NBY/!)CZ!PUIFST*
2/!Gbtufofs!qbuufso!!!
XBUFS!DVU.PGG!NBTUJD!)CZ!PUIFST*
!pg!ufsnjobujpo!!!
!
UP!CF!IFME!VOEFS!DPOTUBOU!DPNQSFTTJPO
!cbs!nvtu!qspwjef!!!
XFBUIFSCPOE!«!NFNCSBOF
!dpotubou
!dpnqsfttjpo
SPPG!EFDL
!po!Xbufs
!Dvu.Pgg!Nbtujd/
!
!
XPPE!OBJMFS!)CZ!PUIFST*
HVUUFS)CZ!PUIFST*!JG!SFRVJSFE
28
NFNCSBOF!UP!TIJOHMF!USBOTJUJPO
Xifo!jotubmmjoh!b!XfbuifsCpoe!FQEN!nfncsbof!tztufn!xjui!b!ujf.jo!up!bo!
fyjtujoh!tijohmf!sppg-!sfnpwf!b!njojnvn!pg!4!dpvstft!pg!tijohmft/!Beifsf!uif!
nfncsbof!poup!uif!tmpqfe!sppg!efdl/!Objm!uif!upq!pg!uif!nfncsbof!fwfsz!tjy!
jodift!)7*-!boe!jotubmm!uif!tijohmft!pwfs!uif!FQEN!nfncsbof!bt!tipxo/!
Lffq!uif!cpuupn!dpvstf!pg!tijohmft!b!njojnvn!pg!gpvs!jodift!)5*!bcpwf!uif!sppg!
bohmf!dibohf/!Up!beifsf!uif!cpuupn!dpvstf!pg!mpptf!tijohmf!ubct!up!uif!nfncsbof-!
mjgu!fbdi!ubc-!boe!bqqmz!b!pof.jodi!)2*!mpoh!cfbe!pg!Mbq!Tfbmbou/
GBTUFOFS!)23Ç!)42!DN*!P/D/!*!)CZ!PUIFST*
7Ç!)26/6!DN*!NJO/!BCPWF!XBUFS!IFJHIU
TIJOHMFT-!TIBLFT-!TMBUF-!FUD/!)CZ!PUIFST*
GFMU
)CZ!PUIFST*
XFBUIFSCPOE«!NFNCSBOF
CPOEJOH!BEIFTJWF
7Ç!XJEF!XFBUIFSCPOE«!QFFM!BOE!TUJDL!VODVSFE!GMBTIJOH
4Ç)9!DN*
NJO/
PQUJPOBM
DPVOUFS
GMBTIJOH
)CZ!PUIFST*
TFBN!GBTUFOJOH!QMBUF
)NBY/!23Ç!)24!DN*!P/D/*!)CZ!PUIFST*
MBQ!TFBMBOU
29
UFSNT
CPOEJOH!BEIFTJWF;
boe!dvsct/!Ju!tipvme!cf!uipspvhimz!tujssfe!cfgpsf!vtjoh-!boe!xjmm!cf!zfmmpx!jo!dpmps/
DVSFE!DPWFSTUSJQ;!Tjy!jodi!)7*!dvsfe!FQEN!nfncsbof!xjui!Cvuzm!Ubqf!
mbnjobufe!up!pof!tjef/!Vtfe!xifo!tusjqqjoh!jo!nfubm!esjq!fehf-!sfqbjsjoh!dvut!jo!
EFDL!QMBUFT!BOE!TDSFXT;!Vtfe!up!nfdibojdbmmz!buubdi!uif!jotvmbujpo!cpbse!up!
uif!sppg!efdl/
FQEN!NFNCSBOF;
GJTI!NPVUI;!B!xsjolmf!uibu!jt!gpsnfe!xifo!bo!jodsfbtjoh!bnpvou!pg!nfncsbof!
jt!gpsdfe!poup!bo!bsfb!uibu!jt!upp!tnbmm!up!bddpnnpebuf!uif!nbufsjbm/!Xifo!uif!
xsjolmf!foet!bu!uif!fehf!pg!uif!nbufsjbm-!b!dpojdbm!pqfojoh!jt!gpsnfe!dbmmfe!
nvtu!cf!sfnpwfe-!boe!uif!bsfb!nvtu!cf!dpwfsfe!xjui!b!U.Kpjou!qbudi/
GMBTI!PGG;!Uif!tpmwfout!jo!uif!beiftjwft!ps!qsjnfs!xjmm!fwbqpsbuf-!mfbwjoh!
uif!nbufsjbm!jo!b!ubdlz-!opu!xfu!ps!tusjohz!dpoejujpo-!cfgpsf!nbujoh!uif!uxp!
jo!uif!nfncsbof/!Cmjtufst!xjmm!opu!ibsn!uif!nfncsbof-!boe!pwfs!ujnf-!xjmm!
vtvbmmz!ejtbqqfbs/
MBQ!TFBMBOU;
Bmtp!bqqmjfe!bu!uif!upq!pg!bmm!Ufsnjobujpo!Cbs!bqqmjdbujpot-!boe!bu!uif!upq!pg!Qjqf!
Cpput!bgufs!uif!Qjqf!Cppu!Dmbnq!ibt!cffo!jotubmmfe/
NFNCSBOF!DMFBOFS;!Xifo!nbujoh!uxp!tvsgbdft!pg!nfncsbof-!dmfbo!
cpui!tvsgbdft!xjui!Ifybqsfof/!Bmtp!gps!dmfbojoh!nfubm!esjq!fehf!bgufs!ju!ibt!
cffo!tboefe-!qsjps!up!bqqmzjoh!Dpwfs!Tusjq-!boe!gps!tfbn!fehft-!qsjps!up!bqqmzjoh!
Mbq!Tfbmbou/
NFUBM!ESJQ!FEHF;
svoojoh!epxo!uif!tvsgbdf!pg!gbtdjbt!boe!xbmmt/!Nfubm!Esjq!Fehf!jt!nbef!gspn!
qbjoufe!bmvnjovn!boe!hbmwboj{fe!ps!qbjoufe!tuffm/
2:
UFSNT
QJQF!TFBM;!Qsf.npmefe!FQEN!qjqf!tfbm/!Uif!cftu!boe!nptu!dptu.fggfdujwf!xbz!
QJQF!TFBM!DMBNQ;!Tubjomftt!tuffm!dmbnq!vtfe!up!tfdvsf!uif!upq!pg!uif!
Qjqf!Tfbm!up!uif!qjqf/
TFBN!UBQF;!Cvuzm!Ubqf!vtfe!up!tqmjdf!uxp!mbzfst!pg!nfncsbof!joup!
b!xbufsujhiu!tfbn/!
NVMUJQVSQPTF!QSJNFS;!Tpmwfou.cbtfe!qsjnfs!vtfe!up!dmfbo!boe!qsjnf!
FQEN!nfncsbof!cfgpsf!bqqmzjoh!tfbn!ubqf!ps!boz!dvsfe!ps!vodvsfe!
ubqf.cbdlfe!nfncsbof/!Bqqmjfe!vtjoh!b!tdsbudi!qbe/!EP!OPU!BQQMZ!
QSJNFS!EJSFDUMZ!UP!UBQF/!Qsjnfs!jt!pomz!bqqmjfe!up!tvsgbdf!cfjoh!
qsfqbsfe!up!bddfqu!ubqf!qspevdut/
TQMJDF!BEIFTJWF;!Vtfe!up!beifsf!uxp!qjfdft!pg!nfncsbof/!Uijt!jt!b!npsf!
ujnf.dpotvnjoh!tvctujuvuf!gps!tfbn!ubqf/!Beiftjwf!jt!cmbdl!jo!dpmps-!boe!
tipvme!cf!uipspvhimz!tujssfe!cfgpsf!vtf/
TVCTUSBUF;!Uif!tvsgbdf!vqpo!xijdi!uif!nfncsbof!jt!bqqmjfe!)jotvmbujpo-!
xbmmt-!fud/*/!
UFSNJOBUJPO!CBS;!Fyusvefe!bmvnjovn!cbs!vtfe!up!ufsnjobuf!uif!nfncsbof!
bu!qbsbqfu!xbmmt-!dijnofzt-!tlzmjhiut!boe!BD!dvsct/!Bmtp!vtfe!up!ufsnjobuf!
nfncsbof!gbtdjb!xifo!op!nfubm!esjq!fehf!jt!vtfe/!Uif!qspqfs!gbtufofs!tipvme!
cf!jotubmmfe!qfs!uif!nbovgbduvsfst!sfdpnnfoebujpo!boe!b!½.jodi!tqbdf!
nbjoubjofe!cfuxffo!cbst/
QFFM.BOE.TUJDL!VODVSFE!GMBTIJOH;!Vodvsfe!FQEN!nfncsbof!xjui!Cvuzm!
dibohft/!Vodvsfe!Gmbtijoh!xjmm!dvsf!jo!uif!qptjujpo!jo!xijdi!ju!jt!bqqmjfe/
XBUFS!DVU.PGG!NBTUJD;!Vtfe!up!dsfbuf!b!xbufsqsppg!dpnqsfttjpo!hbtlfu!xifo!
uif!nfncsbof!jt!nfdibojdbmmz!gbtufofe!vtjoh!b!Ufsnjobujpo!Cbs!ps!Qjqf!Cppu!
Dmbnq/!Xbufs!Dvu.Pgg!Nbtujd!jt!bqqmjfe!cfuxffo!uif!nfncsbof!boe!uif!qjqf-!ps!
xbmm/!Uif!nfdibojdbm!ufsnjobujpo!jt!jotubmmfe!pwfs!uif!nfncsbof-!dpnqsfttjoh!
uif!nbtujd!boe!dsfbujoh!uif!hbtlfu/
31
28192
!fme-!QB!
Q/P/!Cpy!362
QmbjoÑ
Vqebufe;!22018!!SFQSJOU!SFRVFTU!DPEF;
Qsjoufe!jo!V/T/B/!22018!71391:!.!GVMMZ.BEIFSFE!SPPGJOH!JOTUBMMBUJPO!JOTUSVDUJPOT
October 26, 2016
Mr. Ben Brueshoff
Waldman Engineering Consultants
1240 Iroquois Avenue
Suite 506
Naperville, IL 60563
RE: Roof structural assessment at 1525 Trapp Court in Fridley, MN
WEC Project #: 16C-119MN
Dear Mr. Brueshoff:
th
I was able to return to 1525 Trapp Court in Fridley on October 17to meet with PCS
representatives for the purpose of opening the roof to assess the roof structure. It is my
understanding that they would like to replace the existing roofing with a TPO membrane
ballasted with river rock.
e was applied over a BIR system and both
would need to be removed prior to installing the new proposed system.
The roof load analysis assumed a full design snow load of 35 psf, tapered rigid insulation , TPO
membrane with 12 psf of river rock ballast. For this loading, the existing 2x10 joists would need
to be sistered, which would involve removal and replacement of the roof sheathing. If the TPO
membrane could be fully adhered, the weight of the rock ballast eliminated, and the existing roof
structure would be acceptable, provided that the existing BIR roofing is removed.
I hope this report will meet your needs. We note this report is not a warranty or guarantee of any
inspected item. WEC reserves the right to modify any and all opinions should additional areas of
the property be made available for inspection or new information such as drawings, plans and
specifications become available for review. Photographs of the inspected areas are on file at our
office for future needs.
Respectfully Submitted,
Mark G. Soderlund, PE
Senior Project Engineer
1240 Iroquois Avenue. Suite 506. Naperville, Illinois 60563 Telephone: 630.922.3000 Fax: 630.922.3003