solar, 3 ' ,M . solar,--['
� � O ..tiD
O O
O
Optimized installation with HD-Wave technology
Specifically designed to work with power optimizers UL1741 SA certified,for CPUC Rule 21 grid compliance
Record-breaking 99% weighted efficiency Small, lightweight, and easy to install both
outdoors or indoors
Quick and easy inverter commissioning directly from
a smartphone using the SolarEdge SetApp Built-in module-level monitoring
Fixed voltage inverter for longer strings Optional: Faster installations with built-in
consumption metering (1% accuracy) and
Integrated arc fault protection and rapid shutdown production revenue grade metering (0.5% accuracy,
for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20)
690.11 and 690.12
solaredge.com solar
Single Phase Inverter with HD-Wave Technology
for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/
SE760OH-US / SE1000OH-US / SE1140OH-US
APPLICABLE TO INVERTERS S ♦1♦ ♦♦
WITH PART NUMBER
OUTPUT
Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
Maximum AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA
3300 @ 208V 5000 @ 208V 10000 @ 208V
AC Output Voltage Min.-Nom.-Max ✓ ✓ ✓ ✓ i ✓ ✓ Vac
(211-240-264)
AC Output Voltage Min.-Nom.-Max. ✓ - ✓ Vac
(183-208-229)
AC Frequency(Nominal) 59.3-60-60.50) Hz
Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A
Current @240V
Maximum Continuous Output _ 16 - 24 - - 48.5 A
Current @208V
Power Factor 1,Adjustable-0.85 to 0.85
GFDI Threshold 1 A
Utility Monitoring,Islanding Protection, Yes
Country Configurable Thresholds
INPUT
Maximum DC Power @240V 4650 1 5900 1 7750 1 9300 1 11800 1 15500 1 17650 W
Maximum DC Power @208V - 5100 7750 15500 W
Transformer-less,Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380 400 Vdc
Maximum Input Current @240V(1) 8.5 10.5 1 13.5 1 16.5 20 1 27 1 30.5 Adc
Maximum Input Current @208V(1) - 9 13.5 - 27 Adc
Max.Input Short Circuit Current 45 Adc
Reverse-Polarity Protection Yes
Ground-Fault Isolation Detection 600ksa Sensitivity
Maximum Inverter Efficiency 99 99.2
CEC Weighted Efficiency 99 99 @ 240V
98.5 @ 208V
Nighttime Power Consumption <2.5 W
(1)For other regional settings please contact SolarEdge support
(2)A higher current source may be used;the inverter will limit its input current to the values stated
Single Phase Inverter with HD-Wave Technology
for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/
SE760OH-US / SE1000OH-US / SE1140OH-US
ADDITIONAL FEATURES
Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional)
Revenue Grade Metering,ANSI C1220
Optionally
Consumption metering
Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection
Rapid Shutdown-NEC 2014,NEC Automatic Rapid Shutdown upon AC Grid Disconnect
2017 and NEC 2020,690.12
STANDARD COMPLIANCE
Safety UL1741,UL1741 SA,UL169913,CSA C22.2,Canadian AFCI according to TILL.M-07
Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI)
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG
DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG
AWG Range
Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 in/mm
Weight with Safety Switch 22110 25.1/11.4 262/11.9 38.8/17.6 lb/kg
Noise <25 1 <50 dBA
Cooling Natural Convection
Operating Temperature Range -40 to+140/-40 to+60t4I -F/-C
Protection Rating NEMA 4X(Inverter with Safety Switch)
(3)Inverter with Revenue Grade Meter P/N:SExxxxH-lJS00013NC4;Inverter with Revenue Grade Production and Consumption Meter P/N:SExxxxH-lJS00013NI4.For consumption metering,current transformers
should be ordered separately:SEACT0750-20ONA-20 or SEACT0750-400NA-20.20 units per box
(4)Full power up to at least 50°C/122°F,for power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf
How to Enable Consumption Monitoring
By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service
panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills
Single phase inverter with
HD-wave technology and
built-in RGM and
Service Panel consumption monitoring
Grid -
r
CT L1 IN L2
Shielded CATSe cable
Ll
L2 015
AC Conduit
®SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S
other trademarks mentioned herein are trademarks of their respective owners.Date:121202ON011ENG NAM.Subject to change without notice.