Loading...
HomeMy WebLinkAbout5284 Taylor St, Fridley. Addition 02.14.2022 (2) E0 PROPERTY LINE: 131' 0" E0 LO ih 0 DECK NORTH \ 00 15'-0" \%\\�\2\3'-2 86'-6" 0\1 Of N PROPOSED N ADDITION N N EXISTING STRUCTURE w " M AVA STUDIO z ct�' 4332 Brookside Ave St Louis Park MN 55436 EMAIL PROHOMEEXTERIOR@YAHOO.COM w O Q O Q ` --------------��� AVAST U D I O.H O UZZ.C O M �vtg: .:� t -- -= , 5268 5284 TAYLOR ST NE, _ FRIDLEY MN, 55421 0 13 q, n Site Plan 3D Render Rear ALL PLANS ARE TO BE REVIEWED BY THE GENERAL PROPERTY LINE: 30' 11" 2 CONTRACTOR AND THE MUNICIPAL BUILDING 12" = 1'-0" OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. PLAN INFORMATION CODE INFORMATION Area Schedule... Sheet List Name Area FRAMING NOTES: INSULATION: CODE INFORMATION: -ALL EXTERIOR WALLS TO BE 2X6 @ 16"O.C.WITH -ALL EXTERIOR WALLS TO HAVE A MINIMUM RATING OF SINGLE FAMILY CONSTRUCTION TYPE IRC-1 Sheet Name Sheet Number A DOUBLE TOP PLATE UNLESS OTHERWISE R-20 -2020 MINNESOTA STATE RESIDENTIAL CODE Upper level 481 SF NOTED. -ALL ATTIC SPACES ARE TO HAVE A MINIMUM RATING OF -2017 NATIONAL ELECTRICAL CODE -WALL FRAMING SHALL BE S.P.F. STUD GRADE OR R-49 -2020 MINNESOTA STATE MECHANICAL&FUEL GAS CODE Cover Page A100 Addition BETTER UNLESS NOTED OTHERWISE(U.N.O.) -ALL FLOOR SPACES OVER UNCONDITIONED SPACE OR -2020 MINNESOTA STATE FIRE CODE Elevations & Section A200 Lower 478 SF -ALL HEADERS SHALL BE (2)-2X10 U.N.O. CANTILEVERED ARE TO HAVE A MINIMUM RATING OF -2020 MINNESOTA PLUMBING CODE Level -EXTERIOR SHEATHING SHALL BE 7/16" MATERIAL R-30 Foundation & Floor Plans A300 CONSISTING OF ORIENTED STRAND BOARD (OSB). Bracing Plans A400 Addition raCn -ALL FLOOR AND CEILING SYSTEMS TO CHECKED SHEETROCK: SOIL TYPE: g AND DESIGNED BY THE DESIGNATED -ALL CEILINGS ARE TO HAVE 5/8" NON-SAG GYPSUM DESIGNED WITH 2O00 PSF SOILS,ALL MANUFACTURER. TRUSS PLANS TO BE ON SITE @ BOARD U.N.O. FOUNDATION CONSTRUCTION MUST FACTOR IN TIME OF FRAMING -ALL WALLS ARE TO HAVE 1/2"GYPSUM BOARD U.N.O. THIS AT MINIMUM -PRESSURE TREATED WOOD IS TO BE USED -GARAGE CEILING AND WALLS THAT ADJOIN HOUSE WHERE WOOD IS IN CONTACT WITH CONCRETE WALLS ARE TO BE 5/8"TYPE "X"GYPSUM BOARD U.N.O. WIND EXPOSURE: *SITE PLAN BY OTHERS AND AT 2X6 MUD SILL.TREATED MEMBERS TO BE -ALL EXTERIOR WALLS OF GARAGE AND HOUSE THAT ARE DESIGNED WITH "EXPOSURE B"CLASSIFICATIONS S.Y.P.#2 OR BETTER. WITHIN 5'SETBACK TO HAVE 5/8"TYPE "X" EXTERIOR AND WIND GUSTS OF 115 MPH PER 2020 MN IRC -FOR OPENINGS IN EXTERIOR WALLS(OR WALLS GRADE GYPSUM BOARD ON EXTERIOR SIDE OF WALL AND CODE REGULATIONS. WITH LATERAL LOADING: 5/8"TYPE"X"ON INTERNAL SIDE OF WALL. a) 0'-0"-4'-0"= 1 JACK STUD b)4'-0"-8'-0"=2 JACK STUDS GENERAL NOTES: 52 Q/�V`"r Taylor S}` N E c) 8'-0"- 12'-0"= 3 JACK STUDS DOORS AND WINDOWS: -ALL FOUNDATION WALL STRUCTURAL d) GREATER THEN 12' = CONSULT ENGINEER. ALL WINDOWS AND DOORS TO NE DOUBLE GLASS INFORMATION USED TO CONSTRUCT THE -POSTS CALLED OUT ARE NUMBER OF KING PANELS WITH LOW-E RATINGS. FOUNDATION SYSTEM IS TO BE ON SITE WHEN STUDS REQUIRED PER SIDE OF OPENING. -ANY WINDOW WITHIN 24"OF A DOOR SWING MUST BE POURING OR BUILDING WALLS. TEMPERED -ALL STRUCTURAL BEAMS, POSTS&TALL WALLS Fridley M N , 55421 -ANY WINDOW ABOVE A TUB MUST BE TEMPERED ARE TO BE BUILT PER I-LEVEL SPECIFICATIONS. CONCRETE NOTES: -ANY WINDOW WITHIN A STAIRWAY MUST BE TEMPERED -ALL MANUFACTURED FLOORS & ROOF TRUSSES -ALL CONCRETE FOOTINGS AND FOUNDATION -WINDOW GLAZING MUST BE AT LEAST 18"ABOVE ARE TO BE INSTALLED PER MANUFACTURERS SYSTEMS ARE DESIGNED FOR A 2000 P.S.F. SOIL FINISHED FLOOR WHEN WINDOW IS ABOVE 6' FROM SPECIFICATIONS. Cover Page -FOUNDATION WALLS SHALL BE FULL HEIGHT AT GRADE. -ALL MANUFACTURED FLOOR& ROOF TRUSS UNBALANCED FILL GREATER THEN 3'-4" -ALL BEDROOMS TO HAVE AT LEAST ONE WINDOW THAT SPECIFICATIONS ARE TO BE ON SITE DURING -1/2"ANCHOR BOLTS EMBEDDED 7" MINIMUM @ 4' HAS A CLEAR EGRESS OPENING OF 5.7 SQ. FT.WITH MIN. INSTALLATION. O.C. MAX. 12" MIN. FROM EACH END. MINIMUM OF 2 DIMENSIONS OF 24" IN HEIGHT AND 20" IN WIDTH, SILL Project number 5284 HEIGHT NOT TO BE GREATER THEN 44"ABOVE FINISHED BOLTS IN EACH SILL PLATE FLOOR. WINDOW FALL PREVENTION DEVICES Date 02/14/2022 -PAD FOOTINGS REINFORCEMENT IS -WINDOWS WITH SILLS WITHIN 3' OF THE FLOOR THEY AND WINDOW GUARDS SHALL COMPLY LOCATED 3" FROM BOTTOM OF FOOTING TYP.(WHEN REQUIRED) SERVE AND ARE 72"ABOVE GRADE MUST EITHER HAVE A WITH THE REQUIREMENTS OF ASTM F Drawn by Ilya Kazlouski -CONTRACTOR IS RESPONSIBLE FOR ALL STEEL FALL PREVENTION OR OPENING LIMITER DEVICE PER 2090 a REBAR SIZING PER STATE AND LOCAL BUILDING CODE. CODES WINDOW AND EXTERIOR DOOR U- N MECHANICAL 8A ELECTRICAL: A O O LP M -MIN. 5000 PSI CONCRETE(&_ALL FOOTINGS -ALL ELECTRICAL AND MECHANICAL EQUIPMENT TO FACTOR TO BE 0.30 OR BETTER BE VERIFIED AND INSTALLED PER CODE BY GLASS SOLAR HEAT GAIN COEFFICIENT C" N APPROVED TRADES AND INSTALLERS. (SHGC) TO BE 0.28 OR BETTER Scale As indicated N W z >J oe O L W X W Lu W cc O RIDGE VENT(OR SIMILAR) o TO MATCH EXISTING - - - NEW ASPHALT SHINGLES - - ALUMINUM SOFFIT - & FASCIA W / W � _ T NEW LAP SIDING O N w •t ' TO MACTH EXISTING o M . •�OJIL N OL IR —irl REMOVE a3 - 17WINDOW W o I 2 \ N w O r — Ir zLL LU o a AVA STUDIO H]16 -1 �� - 0 4332 Brookside Ave St Louis Park MN 55436 EMAIL PROHOMEEXTERIOR@YAHOO.COM AVASTUDIO.HOUZZ.COM SLOPE GRADE AWAY FROM BUILDING —6" MIN. BETWEEN SIDING III AND GRADE MIN.- - 40" HEIGHTI I 1 III III - -RETAINING WALL- EI W�- EI W F�_,W�- -I — 11'- 1" RearLeft U 1/4" = 1'-0" 1/4" = 1'-0" ROOF : VENT ROOF 1/300 TH.VALLEYS& ALL ROOF/WALL INTERSECTIONS 30 YR ARCHITECTURAL ASPHALTIC SHINGLES 15#ASPHALT FELT ICE&WATER SHIELD (FIRST 6'-0" AND ALL VALLEYS AS PER CODE) 1/2" PLYWD. SHTG.W/CLIPS ENG. ROOF TRUSSES @ 24"O.C. AIR CHUTE (PROVIDE UNOBSTRUCTED AIR FLOW) (R-49) BLOW IN INSULATION 4 MIL. POLY VAPOR BARRIER ALL PLANS ARE TO BE REVIEWED BY THE GENERAL 5/8"GYP. CEILING BD. CONTRACTOR AND THE MUNICIPAL BUILDING ENG. ROOF TRUSSES @ 24" O.C. EXISTING FASCIA : (MATCH EXISTING SLOPE &SIZE) ROOF TRUSSES OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE 2X6 SUB FASCIA FOR ANY PROBLEM AS A RESULT OF AN ERROR 6"ALUMINUM FASCIA — — T.O. Upper Level OMISSION ON THESE PLANS. ALUMINUM VENTED SOFFIT 13' - 1 1/8" WALL : R-49 CLOW IN INSUL. 4 MIL. POLY.V.B. 1/2"GYP. BD. TYP. 5/8"GYP. BD. CEILING 4-MIL. POLY VAPOR BARRIER 00 (R-21) FBGLS. BATT INSULATION — — — — �- — T.O. Main Level 2X6 STUDS @ 16"O.C. 9' - 0 5/8" 1 ao 7/16"OSB SHEATHING TYVAKE HOUSE WRAP *NEW SIDING PER ELEVATION 3/4"OSB SUBFL. Wiper Level RIM BETWEEN LEVELS 2x10 FLOOR JOISTS @ 16 O.C. TO MATCH EXISTING EXISTING 2x10 JOISTS 5' - 0" 7/16"OSB RIM SHEATHING — — O B-Se ent 2X4 CONTINUOUS RIBBON BD. BD. (R-21) CLOSED SELL FOAM INSUL. RIM 2X10 TREATED LEDGER \� - - 5/8"GYP. BD. CEILING 4' - 2" ATTACHED WITH LEDGERLRLOK DURASEAL OR SAME QLTY. 5"SCREWS "W" PATTENT 12"O.C. AND 2 AT EACH END OF LEDGER -' EXISTING CONC. FLOOR Main Level RIM BETWEEN LOWER AND MAIN LEVELS 0O PATCH AND REPLACE 0' - 11 1/2" 7/16"OSB RIM SHEATHING AS NEEDED T.O. Fo datOn TREATED 2X8 SILL PLATE &SILL SEAL TYP. O' - oil (R-21) CLOSED SELL FOAM INSUL. RIM DURASEAL OR SAME QLTY. _ Lower Level 5284 Taylor St NE FOUNDATIONij — — : •_ _; -.  -3' - 6" _z- 1/2" DIAMETER A.B.W/7" MIN. EMBEDDED&2" 12" DIA. C.I.P. CONC PIER 48" —TOP COURSE 6"CMU 3.5" IC SLAB (MATCH EXISTING)_ -°— SIDE X 1/8"THICK SQUARE OR ROUND BELOW GROUND W/24" BELL 4 COURSES-I OVER 6 MIL. POLY.VAPOR BARRIER z - COUNTERSINK WASHERS @ 72"AND WITHIN 12" WITH SIMPSON ABAZ66 POST �•_. —12"CMU BLOCK- OVER 4"GRANULAR COMPACT FILL x o- Fridley M N 5 5421 FROM EACH CORNER&WINDOW WELL BASE ATTACHMENT TO 6x6— —42" BELOW GRADE MIN.- III - W T.O. FOOtin --�, 7 WEATHER RESISTANT OPAQUE PROTECTIVE COATING POST w/(1) 1/2" DIA.ANCHOR _ 20"x8"CONC. FTG. TYP. {� { TO 6" BELOW GRADE MIN. BOLT TYP.-I III IT III -7' - 1 1/2" %AF (R-10)2"(XPS) FOAM INSULATION COMPLYING WITH -III Elevations & Section ASTM C578 - ASPHALT EMULSION PAINT WATERPROOFING EXTERIOR SIDE AND TOP OF WALL Project number 5284 12"CMU BLOCK 5 COURSES MIN. Date 02/14/2022 42" BELOW GRADE MIN. U.N.O. 20"X 8"CONC.FTG.W/REBAR AS PER CODE Drawn by Ilya Kazlouski 5000 PSI MIN COMPRESSIVE STRENGTH a LO N Section 1LP 1/4" = 1'-0" A200 M N N O Scale 1/4" = 1'-0" N 3 3 A200 A200 23'-2" 23'-2" 10'- 1" 13'- 1" 4'- 11 9/32" 23'-2" 5'-3" 7'-6" 3'-7 1/2" 3'-7 1/2" 3'-2" 9'- 10 3/4" 13'-3 1/4" oe 23'-2" 4'-0" 9'-0" 00 3'-41/2" 3'-41/2" 3'-5" 7'-7" 7'-61/2" 7'-7" 12" DIA. C.I.P. CONC PIER 48" == ==- -�-= =-=-= -=-�- ====-=-= =-=- z BELOW GROUND W/24" BELL II WITH SIMPSON ABAZ66 POST i� �i PRIVATE Q BASE ATTACHMENT TO 6x6 o II DEC + POST w/(1) 1/2" DIA.ANCHOR ili N BOLT TYP. o 0 ill w C U ii 0 TREATED DECKING O Q 1-- 0 60 X w 2X10 TREATED LEDGER BD. W O �2 FOUNDATION ATTACHED WITH LEDGERLOK 10'-8" WALL STEP II AVA STUDIO (2x6 BLOCKING) II Q _ 5"SCREWS "W" PATTENT 12"O.C. I I 2'=6" � 3'-�0" 3'�0" AND 2 AT EACH END OF LEDGER - a'=o 2'-6"— a'-o 2'=6°_ 4332 Brookside Ave St Louis Park MN 55436 a'_A 5 a'-o" a'-o" a'-o" a'-o" EMAIL PROHOMEEXTERIOR@YAHOO.COM EGRESS F -� •-, - 2'-4°6'-8" TEMPERED 6"CMU HALF WALL TOP COURSE 6"CMU - 5 COURSES 12"CMU 4 COURSES 12"CMU - 42" BELOW GRADE MIN. 42" BELOW GRADE MIN. MASTER AVASTUDIO.HOUZZ.COM 20"x8"CONC. FTG. TYP. 20"x8"CONC. FTG. TYP. !� - ao W.I.C. BEDROOM co o 12'6"x12' 9" o_ 2x10 @ 16"O.C. TO MATCH EXSITING J L 8' CEILING o - CARPET FLOOR , BEDROOM #3 z : a"cbNc.' av PAD - ENG. ROOF TRUSSES @ 24"O.C. � 9'6°x13'4" m FAMILY ROOM -" •_ .. _.,-• - '" � - - - - - - - - - - N 7' 8"CEILING CARPET FLOOR o 12'6"x 21'7" N a� 6'-6 3'-7" J 7' 8"CEILING 3'- 101/4" 5'-41/4" 3'- 11" -10 CARPET FLOOR SD NEW o o CONC. PAD 20"W.X 8" D. N is UNDER BEARING WALL - N CLOSET `° W/2#4 TYP. "' BEDROOM #1 NOTE: PROVIDE (1)#4 X2'-0" LONG DOWEL@ N 6'-6" U) 9' C x IN 7" o FAN 8' CEILING TOP COURSE AND MIDDLE COURSE& N � N 00 2PLY 9 1/4" o w CARPET FLOOR N (2)#4 2'-0" LONG DOWELS @ STRIP FOOTING. W LVL HDR. c7 -5 1/4" 2'- 11" EPDXY GROUTED INTO EXISTING STER WALL(6" MIN. EMBED) &GROUT NEW WALL w STORAGE/ III NOTE: PROVIDE 1 #4 X2'-0" LONG DOWEL _ - - _ BATH CORES SOLID AT DOWELS TOP COURSE AND COURSE& @ i O O CLOSET EXISTING � SD CT FLOOR 2 #4 2'-0" LONG DOWELS STRIP FOOTING. FOOTING ( ) @ CM EPDXY GROUTED INTO EXISTING LO CUSTOM WALL(6" MIN. EMBED) &GROUT NEW WALL W.I. 2'-6"6'-8° SD ? CORES SOLID AT DOWELS 2'-6"6'-8° SHOWER 60"VANITY -� �10,-4„Cro-- -- - C/O o MATCH EXISTING 4 -0" demolished wall line WALL LINE cn ALL PLANS ARE TO BE REVIEWED BY THE GENERAL y NEW PARTITION WALL 0 DIRECTLY UNDER C w CM CONTRACTOR AND THE MUNICIPAL BUILDING w BEDROOM #4 EXISTING BEAM p BEDROOM #2 OFFICIAL PRIOR TO CONSTRUCTION. w 9'6"x 11'2" w 9' 5"x 11'6" SD LOFT AVA STUDIO LLC. IS NOT RESPONSIBLE O O 8' CEILING FOR ANY PROBLEM AS A RESULT OF AN ERROR 7' 8"CEILING - CARPET FLOOR 12' 8"x 12'6" OMISSION ON THESE PLANS. co CARPET FLOOR 8' CEILING WOOD FLOOR O - J o 00 SD efrigerato � SD O b 0 EXISTING POST Z N m 2 -6 6 -8 Q U I I I N - L� — — — — -D ——CLOSET ——— 2'-6"6'-8" demolished wall line— C9 N Z N H N U) X L DN N Ll I I I I I I I I I I I I DN o I I I I ILL I - I 5284 Taylor St NE I I Fridley MN , 55421 Foundation & Floor Plans Lower Level n Upper Level 1/4" — 1'-0" U 1/4" — 1'-0" Project number 5284 — — Date 02/14/2022 Drawn by Ilya Kazlouski a LO N A300 M N N O Scale 1/4" = 1'-0" N General Bracing Notes Where floor or roof framing members are perpendicular to exterior braced wall lines above or below, solid blocking shall be provided between the framing members at braced wall panel locations to permit TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED fastening of wall plates in accordance with and shall extend to within 2 inches of the bottom side of the roof sheathing and shall be fastened in accordance with Table R602.3(1). CONTINUOUSLY SHEATHED - EXPOSURE CATEGORY B Solid blocking to be provided @ floor trusses below 7CED-LINTE BRACED WALL LINE = 30-FOOT MEAN ROOF HEIGHT MINIMUM TOTAL LENGTH (FEET) OF BRACED p WALL PANELS braced wall panels. - 10-FOOT WALL HEIGHT REQUIRED ALONG EACH BRACED WALL LINEa All framing and foundations shall be shored and temporarily braced as required by the - 2 BRACED WALL LINES contractor and all minimum nailing shall be in accordance with IRC Table R602.3(1). Lumber shall be minimum#2 SPF with treated lumber to be#2 S. Pine and engineered lumber to have Fb =2600 psi with E _ Methods 2.0.Assume all lumber is of good quality and does not have large splits and checks and Ultimate Braced Wall DWB'WSP, Methods shall be visually inspected by the contractor at the time of construction.All fasteners in contact with treated RETURNHDLD- Design SFB, lumber shall be G185 hot dipped galvanized or equal. PANEL DowN Line Method Method CS-WSP, DEVICES BRACED WALL PANEL AT Wind Story Location PBS, PCP, HPS, END OF BRACED WALL LIE END OF BRACED WALL LINE Spacing` LIB1' GB CS-G, END CONDMONI END CONDITION 2 Speed (feet) BV-WSP,ABW, CS-PF �CONTIMOUSLY SHEATHES _ I (mph) PFH, BRACED WALL LIE CONTINUOUSLY SHEATHED BRACED WALL LINE PFC, CS-SFB Braced Wall Plan Abbreviations 10 3.5 2.0 1.5 20 6.0 6.0 3.5 3.0 30 8.5 8.5 5.0 4.5 BWL. - Braced Wall Line RETURN �a BWP. - Braced Wall Panel INIMUM BRACED WALL PANEL PANEL I�►� I r-, 40 11.5 11.5 6.5 5.5 CS-WSP. -Continuously sheathed wood structural panel AT END OF BRACED WALL LINE 10'MAX FIRST BRACED WALL PANEL TS END CONDRION3 p sEEREOUIREME END CONDITION♦ 50 14.0 14.0 8.0 TC GS. -Wall Panels sheathed w/gypsum board both faces �NBR CE W,Y,LVF� REQUIREMENTS 60 16.5 16.5 9.5 8.0 PFH. - Portal Frame with Holdownds Return panel. 2<'for braced oval Imes sheathed with PFG. - Portal Frame Garage � Hood structural panels 10 6.5 6.5 3.5 3.0 32'for braced wal Ines sheathed with CS-PF. - Continuous Portal Frame structural fiberboard Distance D: 24•for braced wag Ines sheathed with 20 11.5 11.5 6.5 5.5 wood structural panels WSP. - Intermittent wood structural panel 32'for braced wag Ines sheathed with 30 16.= 16.= 9.5 8.0 H D. - Hold Down AVA STUDIO structural fiberboard TT.-Tension Tie 4332 Brookside Ave St Louis Park MN 55436 Hold-down 800 lbs capacity fastened to the edge of the 40 21.5 21.5 12.E 10.5 EMAIL PROHOMEEXTERIOR@YAHOO.COM HOLD'DOVN� FIRST BRACED WALL PANEL device. braced wag panel closest to the corner and 1 END CONDmON S to the foundation or Boor framing below 50 26.5 26.S 5.5 13.r 60 31.5 31.S 18.- 15.` AVASTUDIO.HOUZZLOM a m a m m m m m 23'-2" 23'-2" -9' 4'-9" 4'-0' 9'-9" 1'- 11" 2'-9" 5'-0" 3'-9" 9'-9" 1'- 11" f 10 I I I BWL 1 CS-WSP- CS-WSP - CS-WSP BWL 1 CS-WSP CS-WSP CS-WSP 171-111 C coLL U " o o a co C U U:• 3: \ :;t U U ' U U ALL PLANS ARE TO BE REVIEWED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL STUDIO PRIOR LCT O CONSTRUCTION. AVA IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. - - M - - - N N y C) a d C3 U U U Q /4 MUo V!0 BWL 2 - - - - - - - - - - BWL 2 - - - - - - - - - EXISTING EXTERIOR WALL EXISTING EXTERIOR WALL 5284 Taylor St NE "00 F , o o Fridley MN , 55421 Bracing Plans efrigerato 0 Project number 5284 l i i i i i i Date 02/14/2022 J Lower Level Bracing Upper Level Bracing Drawn by Ilya Kazlouski U 1/4" = 1'-011 U 1/41' = 1'-0" a N A400 M N N O Scale 1/41' = 1'-0" N