Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IR Report - Smith, Alex (2)
Smith,Alex #91e755J ,��IRONRIDGE APPROVED pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Project Details JensenDO3/O3/2O22 Name Smith,Alex Date 02/23/2022 Location 5906 Benjamin Street Northeast, Fridley, MN 55432 Total modules 36 Module Hanwha Q.Cells: Q.PEAK DUO BLK ML-G10+ 395 (32mm) Total watts 14,220 Dimensions 73.98" x 41.14"x 1.26" (1879.Omm x 1045.Omm x 32.Omm) Attachments 88 ASCE 7-16 Rails per row 2 Separate Permits for; Electric System Weight Load Assumptions Total system weight 2,198.9 Ibs Wind exposure B Weight/attachment 25.0 Ibs Wind speed 109 mph Racking weight 452.9 Ibs Ground snow load 50 psf Distributed weight 2.8 psf Attachment spacing portrait 4.0' Attachment spacing landscape 4.0' Site Elevation 889.0 ft SDS 0.051 Roof Information Roof Material Family Comp Shingle Roof material Comp Shingle Building height 30 ft Roof attachment Flashfoot2 Roof slope 30 ° Attachment hardware Square Risk category II Roof shape Gable Span Details XR1OO - Portrait Reaction Forces XR1OO - Portrait Module Max Max Module Down Uplift Lateral Zone Position span cantilever Zone Position (ibs) (ibs) (ibs) Zone 1/2e/2r Normal 6' 1" 2' 5" Zone 1/2e/2r Normal 272 143 135 Exposed 6' 1" 2' 5" Exposed 272 225 135 Edge 6' 1" 2' 5" Edge 272 322 135 Zone 2n/3r Normal 6' 1" 2' 5" Zone 2n/3r Normal 272 164 135 Exposed 6' 1" 2' 5" Exposed 272 257 135 Edge 6' 1" 2' 5" Edge 272 367 135 Zone 3e Normal 6' 1" 2' 5" Zone 3e Normal 272 209 135 Exposed 6' 1" 2' 5" Exposed 272 325 135 Edge 6' 1" 2' 5" Edge 272 461 135 Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 1 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Span Details XR100 - Landscape Reaction Forces XR100 - Landscape Module Max Max Module Down Uplift Lateral Zone Position span cantilever Zone Position Obs) Obs) Obs) Zone 1/2e/2r Normal 7' 5" 3' Zone 1/2e/2r Normal 151 88 75 Exposed 7' 5" 3' Exposed 151 139 75 Edge 7' 5" 3' Edge 151 189 75 Zone 2n/3r Normal 7' 5" 3' Zone 2n/3r Normal 151 100 75 Exposed 7' 5" 3' Exposed 151 156 75 Edge 7' 5" 3' Edge 151 211 75 Zone 3e Normal 7' 5" 3' Zone 3e Normal 151 136 75 Exposed 7' 5" 3' Exposed 151 211 75 Edge 7' 5" 3' Edge 151 285 75 Roof Section 1 Details Weights Panels: 21 Provided rail: 224' [16 x 14'] Total weight: 1,247.0 Ibs Rail orientation: East-West Attachments: 44 Weight/attachment: 28.3 Ibs Panel orientation: Portrait Splices: 6 Total Area: 452.2 sq ft Entry type: Graphical Clamps: 52 Distributed weight: 2.8 psf Diagram T 1 34' 7" Segments Identifier Columns Length Cantilever Rail Attachments Splices Clamps A 10 34' 9" 1'4" 84' [6 x 14'1 18 4 22 B 7 24'4" 2" 56' [4 x 14'1 14 2 16 C 1 3' 7" 0" 28' [2 x 141 4 0 4 Row segment totals (x 2) 56' [4 x 14'1 8 0 8 D 2 7' 1" 1' 6" 28' [2 x 14'1 4 0 6 Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 2 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Roof Section 2 Details Weights Panels: 6 Provided rail: 56' [4 x 14'] Total weight: 350.2 Ibs Rail orientation: East-West Attachments: 12 Weight/attachment: 29.2 Ibs Panel orientation: Portrait Splices: 0 Total Area: 129.6 sq ft Entry type: Graphical Clamps: 16 Distributed weight: 2.7 psf Diagram fV ri 1 13' 10"� Segments Identifier Columns Length Cantilever Rail Attachments Splices Clamps A 4 14' 1' 28' [2 x 14'1 8 0 10 B 2 7' 1" 1' 6" 28' [2 x 14'1 4 0 6 Roof Section 3 Details Weights Panels: 9 Provided rail: 168' [12 x 14'] Total weight: 602.0 Ibs Rail orientation: East-West Attachments: 32 Weight/attachment: 18.8 Ibs Panel orientation: Landscape Splices: 4 Total Area: 193.6 sq ft Entry type: Graphical Clamps: 26 Distributed weight: 3.1 psf Diagram 1 l- 18' 6" Segments Identifier Columns Length Cantilever Rail Attachments Splices Clamps A 3 18. 9.. 1'4" 56' [4 x 141 10 2 8 Row segment totals (x 2) 112' [8 x 14'1 20 4 16 B 2 12' 6" 3" 28' [2 x 14'1 8 0 6 C 1 6' 4" 1' 2" 28' [2 x 14'1 4 0 4 Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 3 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Side View (portrait) 30' PV MODULE RAIL FLASHFOOT2 ROOF MEMBRANE BUILDING STRUCTURE Front View (portrait) 4.0• gTTq INT-N PV MODULE RAIL FLASHFOOT2 ROOF MEMBRANE BUILDING STRUCTURE Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 4 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Side View (landscape) 30° I PV MODULE RAIL FLASHFOOT2 ROOF MEMBRANE BUILDING STRUCTURE Front View (landscape) 4.0• gTTq-NT-N PV MODULE RAIL FLASHFOOT2 ROOF MEMBRANE BUILDING STRUCTURE Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 5 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Splice Details TOP-FACING SLOT XR100 RAIL INTERNAL SPLICE r- — — — — — — — — BONDING SPRING �J XR1001NTERNALSPLICE SIDE-FACING SLOT Splice Connection XR100 Clamp Detail PV MODULE UNIVERSAL RAIL STOPPER FRAME FASTENING 1,. 1„ SLEEVE OBJECT PV MODULE FRAME UNIVERSAL ----- UNIVERSAL FASTENING ________ FASTENING PV MODULE OBJECT -________ ----------________ OBJECT FRAME UNIVERSAL FASTENING r OBJECT RAIL RAI L STOPPER PV MODULE SLEEVE FRAME Mid Clamp,Plan Mid Clamp,Front End Clamp,Plan End Clamp,Front FlashFoot2 Detail 91, n„ 1 is 5, 317 12" d 16 27r Plan View Side View Perspective View Front View Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 6 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Grounding Diagram - - - - - - — - — - - - - - - - - - - — - - — — - — — — — — — - - - - - - — - - - - — — - — - - — — - - - — — — — — 0'. O - - - - - - - + - - - - - - + - - - - - - - - - - - - - - - - - O 3- — - - — - 4 4 10 4 4-t 0 - - - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - OUFO Clamp • Grounding Lug Fault Current Ground Path Min 10 AWG Copper Wire Bonded Splice (Rail Connection) *Grounding Lugs and Wire are not required in systems using Enphase microinverters. Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 7 of 8 Smith,Alex(#916755) /lr IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 Bill of Materials Part Spares Total Qty Rails& Splices XR-100-168A 0 32 XR100,Rail 168"(14 Feet)Clear XR100-BOSS-01-M 1 0 10 Bonded Splice,XR100 Clamps& Grounding UFO-C L-01-A1 0 94 Universal Module Clamp,Clear UFO-STP-32 M M-M 1 0 44 Stopper Sleeve,32MM,Mill XR-LUG-03-Al 0 11 Grounding Lug,Low Profile Attachments FF2-01-M2 0 88 FlashFoot2,Mill BHW-SQ-02-Al 0 88 Square-Bolt Bonding Hardware Accessories 29-4000-077 0 4 Wire Clips,Molded PVC Black,Polybag 20 XR-100-CAP 0 3 Kit,End Cap XR100(10 sets per bag) BHW-MI-01-Al 0 36 Microinverter/MLPE Bonding Hardware,T-Bolt Last updated by Benjamin Ferkinhoff on 02/23/22 03:06 PM Page 8 of 8