Loading...
HomeMy WebLinkAboutFinal Review 5284 Taylor Street PROPERTY LINE: 131' 0" 15'-0" 23'-2" 92' - 10 5/8" oe 10 T NORTH \ i� N DECK185SF APPROVED JensenD05/10/2022 o PROPOSED iv ADDITION r 278 SF W-1 N EXISTING STRUCTURE T AVA STUDIO z tv' 4332 Brookside Ave St Louis Park MN 55436 J EMAIL PROHOMEEXTERIOR@YAHOO.COM o: w a cc - a - - - --- 5268 5284 TAYLOR ST NE, FRIDLEY MN, 55421 — - - LO -- P �GPE� Q n Site Plan 3D View 1 1" = 10'-0" 2 12" = 1'-0" ALL PLANS ARE TO BE REVIEWED BY THE GENERAL PROPERTY LINE: 30' 11" CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE FOR ANY PROBLEM AS A RESULT OF AN ERROR OMISSION ON THESE PLANS. PLAN INFORMATION CODE INFORMATION Area Schedule... Sheet List Name Area FRAMING NOTES: INSULATION: CODE INFORMATION: -ALL EXTERIOR WALLS TO BE 2X6 @ 16" O.C. WITH -ALL EXTERIOR WALLS TO HAVE A MINIMUM RATING OF SINGLE FAMILY CONSTRUCTION TYPE IRC-1 Sheet Name Sheet Number A DOUBLE TOP PLATE UNLESS OTHERWISE R-20 -2020 MINNESOTA STATE RESIDENTIAL CODE Upper level 278 SF NOTED. -ALL ATTIC SPACES ARE TO HAVE A MINIMUM RATING OF -2017 NATIONAL ELECTRICAL CODE Addition -WALL FRAMING SHALL BE S.P.F. STUD GRADE OR R-49 -2020 MINNESOTA STATE MECHANICAL&FUEL GAS CODE Cover Page A100 BETTER UNLESS NOTED OTHERWISE (U.N.O.) -ALL FLOOR SPACES OVER UNCONDITIONED SPACE OR -2020 MINNESOTA STATE FIRE CODE Elevations & Section A200 Lower 278 SF -ALL HEADERS SHALL BE (2) - 2X10 U.N.O. CANTILEVERED ARE TO HAVE A MINIMUM RATING OF -2020 MINNESOTA PLUMBING CODE Level -EXTERIOR SHEATHING SHALL BE 7/16" MATERIAL R-30 Foundation & Floor Plans A300 CONSISTING OF ORIENTED STRAND BOARD (OSB). Addition -ALL FLOOR AND CEILING SYSTEMS TO CHECKED SHEETROCK: SOIL TYPE: Bracing Plans A400 AND DESIGNED BY THE DESIGNATED -ALL CEILINGS ARE TO HAVE 5/8" NON-SAG GYPSUM DESIGNED WITH 2O00 PSF SOILS, ALL MANUFACTURER. TRUSS PLANS TO BE ON SITE @ BOARD U.N.O. FOUNDATION CONSTRUCTION MUST FACTOR IN TIME OF FRAMING -ALL WALLS ARE TO HAVE 1/2" GYPSUM BOARD U.N.O. THIS AT MINIMUM -PRESSURE TREATED WOOD IS TO BE USED -GARAGE CEILING AND WALLS THAT ADJOIN HOUSE WHERE WOOD IS IN CONTACT WITH CONCRETE WALLS ARE TO BE 5/8"TYPE "X" GYPSUM BOARD U.N.O. WIND EXPOSURE: *SITE PLAN BY OTHERS AND AT 2X6 MUD SILL. TREATED MEMBERS TO BE -ALL EXTERIOR WALLS OF GARAGE AND HOUSE THAT ARE DESIGNED WITH "EXPOSURE B" CLASSIFICATIONS S.Y.P. #2 OR BETTER. WITHIN 5' SETBACK TO HAVE 5/8"TYPE "X" EXTERIOR AND WIND GUSTS OF 115 MPH PER 2020 MN IRC -FOR OPENINGS IN EXTERIOR WALLS (OR WALLS GRADE GYPSUM BOARD ON EXTERIOR SIDE OF WALL AND CODE REGULATIONS. WITH LATERAL LOADING: 5/8"TYPE "X" ON INTERNAL SIDE OF WALL. a) 0'-0" -4'-0" = 1 JACK STUD b)4'-0" - 8'-0" = 2 JACK STUDS GENERAL NOTES: 52 Q/�V`T Taylor S+l N E c) 8'-0" - 12'-0" = 3 JACK STUDS DOORS AND WINDOWS: -ALL FOUNDATION WALL STRUCTURAL d) GREATER THEN 12' = CONSULT ENGINEER. ALL WINDOWS AND DOORS TO NE DOUBLE GLASS INFORMATION USED TO CONSTRUCT THE -POSTS CALLED OUT ARE NUMBER OF KING PANELS WITH LOW-E RATINGS. FOUNDATION SYSTEM IS TO BE ON SITE WHEN STUDS REQUIRED PER SIDE OF OPENING. -ANY WINDOW WITHIN 24" OF A DOOR SWING MUST BE POURING OR BUILDING WALLS. TEMPERED -ALL STRUCTURAL BEAMS, POSTS&TALL WALLS Fridley M N ,55421 -ANY WINDOW ABOVE A TUB MUST BE TEMPERED ARE TO BE BUILT PER I-LEVEL SPECIFICATIONS. CONCRETE NOTES: -ANY WINDOW WITHIN A STAIRWAY MUST BE TEMPERED -ALL MANUFACTURED FLOORS & ROOF TRUSSES -ALL CONCRETE FOOTINGS AND FOUNDATION -WINDOW GLAZING MUST BE AT LEAST 18"ABOVE ARE TO BE INSTALLED PER MANUFACTURERS SYSTEMS ARE DESIGNED FOR A 2000 P.S.F. SOIL FINISHED FLOOR WHEN WINDOW IS ABOVE U FROM SPECIFICATIONS. Cover Page -FOUNDATION WALLS SHALL BE FULL HEIGHT AT GRADE. -ALL MANUFACTURED FLOOR & ROOF TRUSS UNBALANCED FILL GREATER THEN 3'-4" -ALL BEDROOMS TO HAVE AT LEAST ONE WINDOW THAT SPECIFICATIONS ARE TO BE ON SITE DURING -1/2"ANCHOR BOLTS EMBEDDED 7" MINIMUM @ 4' HAS A CLEAR EGRESS OPENING OF 5.7 SQ. FT. WITH MIN. INSTALLATION. O.C. MAX. 12" MIN. FROM EACH END. MINIMUM OF 2 DIMENSIONS OF 24" IN HEIGHT AND 20" IN WIDTH, SILL Project number 5284 HEIGHT NOT TO BE GREATER THEN 44"ABOVE FINISHED BOLTS IN EACH SILL PLATE WINDOW FALL PREVENTION DEVICES -PAD FOOTINGS REINFORCEMENT IS TO BE FLOOR. Date 04/25/2022 WINDOWS WITH SILLS WITHIN 3'OF THE FLOOR THEY AND WINDOW GUARDS SHALL COMPLY LOCATED 3" FROM BOTTOM OF FOOTING TYP. SERVE AND ARE 72"ABOVE GRADE MUST EITHER HAVE A WITH THE REQUIREMENTS OF ASTM F Drawn by Ilya KazlOuski (WHEN REQUIRED)-CONTRACTOR IS RESPONSIBLE FOR ALL STEEL FALL PREVENTION OR OPENING LIMITER DEVICE PER 2090 Q CODE. REBAR SIZING PER STATE AND LOCAL BUILDING o CODES WINDOW AND EXTERIOR DOOR U- l @ MECHANICAL& ELECTRICAL: A O O -MIN. 5000 PSI CONCRETE ALL FOOTINGS ALL ELECTRICAL AND MECHANICAL EQUIPMENT TO FACTOR TO BE 0.30 OR BETTER BE VERIFIED AND INSTALLED PER CODE BY GLASS SOLAR HEAT GAIN COEFFICIENT N N CD APPROVED TRADES AND INSTALLERS. (SHGC) TO BE 0.28 OR BETTER Scale As indicated N N WI Z J Q 0 SEPARATE PERMITS FOR: ELECT, PLUMB. MECH. Provide proper sized supply and W x return air ducts to rooms W ❑ W 0 RIDGE VENT (OR SIMILAR) W -- NEW ASPHALT SHINGLES All TO MATCH EXISTING Call for framing inspection prior to building wrap/ siding. - LL 2'- 6" ALUMINUM SOFFIT 1 -6 & FASCIA 0 z - T - - NEW LAP SIDING O - TO MACTH EXISTING o CO d T W N O � • ❑ 0 Q REMOVE ' ¢ •• �WI NDOW O C7 N U ¢ - D z AVA STUDIO ❑ U) 0 4332 Brookside Ave St Louis Park MN 55436 EMAIL PROHOMEEXTERIOR@YAHOO.COM Provide treated bottom plates in basements and proper sized framing nails. ~ SLOPE GRADE AWAY ` FROM BUILDING � � � III III III III III7=7 7 7 77 —6 MIN. BETWEEN SIDING AND GRADE MINI -40 HEIGHTS I I -RETAINING WALL- WF d U I- I- I I -w F F EM M I � I 1 1 � � 11 E n Rear n Left 1/4" = 1'-0" 1/4" = 11 ROOF : Smoke detectors in each VENT ROOF 1/300 TH. VALLEYS& sleeping room and on each level ALL ROOF/WALL INTERSECTIONS of the house per R314 30 YR ARCHITECTURAL ASPHALTIC SHINGLES 15#ASPHALT FELT ICE&WATER SHIELD (FIRST 6'-0" AND ALL VALLEYS AS PER CODE) 1/2" PLYWD. SHTG. W/CLIPS CO detection per R315 ENG. ROOF TRUSSES @ 24"O.C. 2020 1 RC. AIR CHUTE (PROVIDE UNOBSTRUCTED AIR FLOW) (R-49) BLOW IN INSULATION 4 MIL. POLY VAPOR BARRIER Anchor bolts: min 7" embedded in concrete, ALL PLANS ARE TO BE REVIEWED BY THE GENERAL 5/8" GYP. CEILING BD. min 2 per sill, min. 12" from plate ends, min. ENG. ROOF TRUSSES @ 24"O.C. EXISTING CONTRACTOR AND THE MUNICIPAL BUILDING FASCIA: 6 ' O.C. (MATCH EXISTING SLOPE &SIZE) ROOF TRUSSES OFFICIAL PRIOR TO CONSTRUCTION. AVA STUDIO LLC. IS NOT RESPONSIBLE 2X6 SUB FASCIA FOR ANY PROBLEM AS A RESULT OF AN ERROR V Ak 6"ALUMINUM FASCIA — — — — — — — —T.O. Upper Level OMISSION ON THESE PLANS. ALUMINUM VENTED SOFFIT Provide deck attachment for lateral support, min (2) 13' - 1 1/8" WALL : Per section R507.9.2 2020 IRC. R-49 CLOW IN INSUL. 4 MIL. POLY. V.B. 1/2" GYP. BD. TYP. ,' `� 5/8" GYP. BD. CEILING 4-MIL. POLY VAPOR BARRIER w (R-21) FBGLS. BATT INSULATION — — — — — — T.O. Main Level 9' - 05/8" 2X6 STUDS @ 16" O.C. MAX RAIL SPACING 4" w 2x10 FLOOR JOISTS @ 16 O.C. , 7/16" OSB SHEATHING MIN GUARD HEIGHT; ` TO MATCH EXISTING TYVAKE HOUSE WRAP 36" *NEW SIDING PER ELEVATION 3/4 OSB SUBFL. Upper Level RIM BETWEEN LEVELS — — — — EXISTING 2x10 JOISTS 5' - 0" 7/16" OSB RIM SHEATHING T.O. el 2X4 CONTINUOUS RIBBON BD. (R-21) CLOSED SELL FOAM INSUL. RIM 2X10 TREATED LEDGER BD. 5/8'GYP. BD. CEILING 4' - 2" DURASEAL OR SAME QLTY. ATTACHED WITH LEDGERLOK 5" SCREWS "W" PATTENT 12" O.C. _ Main Level AND 2 AT EACH END OF LEDGER — - EXISTING CONC. FLOOR--- - — 0' - 11 1/2" RIM BETWEEN LOWER AND MAIN LEVELS _ 00 PATCH AND REPLACE _ 7/16" OSB RIM SHEATHING AS NEEDED TREATED 2X8 SILL PLATE &SILL SEAL TYP. Ledger attachment to house per R507.9.1.3 2020 IRC T.O. o IOn 0' - 0" (R-21) CLOSED SELL FOAM INSUL. RIM DURASEAL OR SAME QLTY. FOUNDATION Lower3eveel 5284 Taylor St N E 1/2" DIAMETER A.B. W/7" MIN. EMBEDDED &2" - 2" DIA. C.I.P. CONIC PIER SIDE X 1/8"THICK SQUARE OR ROUND ELOW GROUND W/24" BELL a Z - COUNTERSINK WASHERS @ 72"AND WITHIN 12" ITH FROM EACH CORNER &W NDOW WE _ _BASE AT O T AC TO 6x6ST _ T.O. Footing Fridley M N ,55421 WEATHER RESISTANT OPAQUE PROTECTIVE COATING 1)11/2 DIAi ANCHOR1--� -7' - 1 1/2" TO 6" BELOW GRADE MIN. OLT TYP (R-10)2" (XPS) FOAM INSULATION COMPLYING WITH 3.I5I' CONIC SLAB (MATCH(EXISTING) Elevations & Section - ASTM C578 -TO C S 6 C U -OVER 6 MIL. POLY.VAPOR BARRIER ASPHALT EMULSION PAINT WATERPROOFING �2"OCMUSB BLOCK ' III OVER 4" GRANULAR COMPACT FILL EXTERIOR SIDE AND TOP OF WALL 42" BELOW GRADE MIN. Project number 5284 12"CMU BLOCK 5 COURSES MIN. 20"x8" CONC. FTG.TYP. 12" masonry foundation wall Date 04/25/2022 42" BELOW GRADE MIN. U.N.O. reinforcement In accordance with section 20" X 8" CONC.FTG. W/ REBAR AS PER CODE R404.1 .1 (4) 2020 IRC. Drawn by Ilya Kazlouski 5000 PSI MIN COMPRESSIVE STRENGTH Q rn 0 n Section 1 A200 J N N 0 Scale 1/4" = 1'-0" N � 3 3 A200 A200 f 23'-2" 23'-2" 9'- 10 3/4" 2'-4" 10'- 11 1/4" AVA STUDIO 5'-3" T-6" 3'-7 1/2" 3'-7 1/2" 3'-2" 7 4'- 11" 4'- 11 3/4" 5'-2 1/4" 5'-9" 4332 Brookside Ave St Louis Park MN 55436 10'- 1 1/2" 13'-0 1/2" EMAIL PROHOMEEXTERIOROYAHOO.COM 12" DIA. C.I.P. CONC PIER 48" BELOW GROUND W/24" BELL WITH SIMPSON ABAZ66 POST (2) 2X10 TREATED \ BASE ATTACHMENT TO 6x6 ========= ===== == -_______= ____ POST w/(1) 1/2" DIA. ANCHOR BOLT TYP. 7'-7" - 1/2" 7'-7" 2X10 TREATED LEDGER BD. it c i li Emergency escape opening per PRIVA E ATTACHED WITH LEDGERLOK - „ FOUNDATION DEC II „ R310.1 2020 I RC o 5" SCREWS "W" PATTENT 12 O.C. WALL STEP w cl)U _ AND 2 AT EACH END OF LEDGER 00 II � O „ 22'8"x 8 0" w „ TREATEDDECKING CC 2 -6 —a-0— 2 =6— �I 6" CMU HALF WALL 4'-0' 4'-0" 4'-0" 4'-0" 6'o"X DING GLASS DOOR 5 COURSES 12" CMU - 42" BELOW GRADE MIN. _EGRESS_ 2PLv91/4"LVLHDR. 20"x8" CONC. FTG. TYP. TOP COURSE 6" CMU _ o 4 COURSES 12° CMU o � BEDROOM #2 MASTER 42" BELOW GRADE MIN. BEDROOM o 20"x8" CONC. FTG. TYP. - 9' 0"x 9' 2" o W - � °' 8'CEILING 10' 3"x 15' 5" NOTE: PROVIDE (1) #4 X2' 0" LONG DOWELO - v = g a°coNc.' _ - a, CARPET FLOOR T FAMILY ROOM j C3 PAD' O O & CEILING b TOP COURSE AND MIDDLE COURSE & OFFICE N J z ' CARPET FLOOR (2) #4 2'-0" LONG DOWELS O STRIP FOOTING. N z Z iv N N EPDXY GROUTED INTO EXISTING T r 9' 5"x 11'5" W 12' 6"x 21' 0" �, r r SD rf WALL(6" MIN. EMBED) & GROUT NEW WALL T 8" CEILING SD o T 8" CEILING a �' ENG. ROOF TRUSSES O 24" O.C. CORES SOLID AT DOWELS CARPET FLOOR o CARPET FLOOR N X - „NOTE: PROVIDE (1) #4 X2'-0" LONG DOWELO zo TOP COURSE AND MIDDLE COURSE & (2) #4 2'-0" LONG DOWELS O STRIP FOOTING. 2x10 O 16"O.C. TO MATCH EXSITING - EPDXY GROUTED INTO EXISTING ),0""s'-8" SD _WALL " MIN. EMBED) GROUT NEW WALL EXISTING (6 ) &G OU c� 2'-0" - -CLOSET_ — �,� WALLLINE RE LID AT D WEL 10'-4"C/O demolished wall line — — — — — ------- -- — — r 6' - 0" 3'- 10 3/4" 3'-6" 9'-7" demolished wall line O I � r ALL PLANS ARE TO BE REVIEWED BY THE GENERAL NEW PARTITION WALL w 2'-6"6'-8" v CONTRACTOR AND THE MUNICIPAL BUILDING O 0 Lo °C OFFICIAL PRIOR TO CONSTRUCTION. DIRECTLY UNDER Ir W BEDROOM #4 EXISTING BEAM W AVA STUDIO LLC. IS NOT RESPONSIBLE EXISTING W 9' 5"x 11'2" w bo FOOTING 7' 8" CEILING 0 0 BEDROOM #3 \ / FOR ANY PROBLEM AS A RESULT OF AN ERROR 9' 5"x 11' 6" ,� OMISSION ON THESE PLANS. CARPET FLOOR \ \EXISTING BAR/ iv 8' CEILING N N KITCHENETTE CARPET FLOOR 36" X 60" z p I r o SHOWER MASTER o o rn ~ SD CM o efri eratoLL) BATHo 9 � CMCT FLOORz O SD SD - p °° O O S D `D / 0 io EXISTING POST z N H n r II 2•-6"6•-8" LINEN FAN m Q UP, J I I I I I I M zo 2'-6"6'-8' N N �' N N demolished wall line N z 4'-0"6'-8" ' X DN (V Yu N II , 1,01 6'-0" 3' - 10 3/4" DN i i , I Com ustion ir! I I , 5284 Taylor St NE ED I I Fridley MN ,55421 Foundation & Floor Plans Lower Level Upper Level Project number 5284 Date 04/25/2022 Drawn by Ilya Kazlouski a _o A300N N O Scale 1/4" = V-0" Q0 N General Bracing Notes Where floor or roof framing members are perpendicular to exterior braced wall lines above or below, solid blocking shall be provided between the framing members at braced wall panel locations to permit TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED fastening of wall plates in accordance with and shall extend to within 2 inches of the bottom side of the roof sheathing and shall be fastened in accordance with Table R602.3(1). CONTINUOUSLY SHEATHED _ EXPOSURE CATEGORY B Solid blocking to be provided @ floor trusses below JONTINUOUSLYSHEATt% BRACED WALL LINE - 30-FOOT MEAN ROOF HEIGHT MINIMUM TOTAL LENGTH(FEET)OF BRACED braced wall panels. BRACED WALL LINE WALL PANELS 10-FOOT WALL HEIGHT REQUIRED ALONG EACH BRACED WALL LINEa All framing and foundations shall be shored and temporarily braced as required by the 2 BRACED WALL LINES contractor and all minimum nailing shall be in accordance with IRC Table R602.3(1). Lumber shall be minimum #2 SPF with treated lumber to be#2 S. Pine and engineered lumber to have Fb= 2600 psi with E_ Methods 2.0. Assume all lumber is of good quality and does not have large splits and checks and Ultimate Braced Wall DWB,WSP, Methods shall be visually inspected by the contractor at the time of construction. All fasteners in contact with treated RETURN HMD• Design SFB, lumber shall be G185 hot dipped galvanized or equal. PANEL DOWN Line Method Method CS-WSP, BRACED WALL PANEL AT DEVICES BRACED WALL PANEL AT Wind Story Location PBS, PCP, HPS, END OF BRACED WALL LINE END OF BRACED WLL A LIE Spacing` LIBb GB CS-G, ENDCONDmONI END CONDITION 2 Speed (feet) BV-WSP,ABW, CS-PF I�cONTI1l10VSLYSHEATHEEL _ I (mph) PFH, BRACED WALL LIE CONTINUOUSLY SHEATHED BRACED WALL LINE PFC, CS-SFB Braced Wall Plan Abbreviations 3.5 3.5 2.0 �.5 �� 21= 6.0 6.0 3.5 3.0 30 8.5 8.5 5.0 =.5 BWL. - Braced Wall Line RETURN �a BWP. - Braced Wall Panel J1.111111.1UNI DBRACED WALL PANEL PEE` f�� WIMT40 1.5 1 1. 6.5 5.5 ' .. AT END OF BRACED WALL LINE 20'MA CS-WSP. - Continuously sheathed wood structural panel WALL PANEL 'SEE REOUIREAIENTS f!�` END CONDITION 3 END CONDITION 4 50 14.0 14.0 8.0 -.0 GS. - Wall Panels sheathed w/gypsum board both faces _ S2t.M000SLY SHEATHED j _1 BRACED WALL IIINE REQUIREMENTS 60 6.5 16._, 9.5 -;.0 PFH. - Portal Frame with Holdownds ' `•. -I Return panel: 24'for braced war Imes sheathed with PFG. - Portal Frame Garage woad structural panels 10 6.5 6.5 3.5 3.0 32'for braced war Ines sheathed with CS-PF. - Continuous Portal Frame structural fiberboard Distance D: 24'for braced war Imes sheathed with 20 1.5 11. 6.5 5.5 wood structural panels WSP. - Intermittent wood structural panel 32'for braced war Ines sheathed with 30 16.5 16. 9.5 8.0 HD. - Hold Down AVA STUDIO structural fiberboard TT. -Tension Tie 4332 Brookside Ave St Louis Park MN 55436 Hold-down 800Ibs capacity fastened to the edge of the -� 21.5 21. 12.5 10.5 EMAIL PROHOMEEXTERIOROYAHOO.COM HOLD-DC;:'. FIRS-ERACED DEVICE Y:AL_PANEL device. braced war panel closest to the corner and - END CONDITION 5 to the foundation or floor framing below lu 26.5 26. 15.5 13.0 60 31.5 31.5 18.0 15.5 Q m Q m m I I I I I I I I I I I I 23'-2" 2'-5" 5'-0" 4'-0" 9'-01, 2'-9"' I I ALL PLANS ARE TO BE REVIEWED BY THE GENERAL CONTRACTOR AND THE MUNICIPAL BUILDING OFFICIAL PRIOR TO CONSTRUCTION. 23'-2" AVA STUDIO LLC. IS NOT RESPONSIBLE 3'-9" 9'-9" 1'- 11.1 FOR ANY PROBLEM AS A RESULT OF AN ERROR 2'-9" 5'-0" OMISSION ON THESE PLANS. CS-WSP_ CS-WSP_ CS-WSP BWL 1 BWL 1 CS-WSP CS-WSP CS-WSP a [L b .' a o �_, o cn CD c' C 0 O O O O N r ZoLL r o U a- o j- O _ _ j r i U U M U U 1 BWL2 - BWL2 - - - - - EXISTING EXTERIOR WALL EXISTING EXTERIOR WALL 5284 Taylor St NE I I o0 F o o Fridley MN ,55421 II � o Bracing Plans efrigerato o0 Project number 5284 Date 04/25/2022 n Lower Level Bracing Upper Level Bracing Drawn by Ilya Kazlouski 1/411 = 11-Ot' 1/4" = 11-011 Q A400N N O Scale 1/411 = 11-011 N