HomeMy WebLinkAboutPermit Approved - Payment Due (3) From: Trisha.Lindahl@fridleymn.gov
Sent: 05/17/2022-01:35 PM
To: emirosangiovanni@gmail.com
CC:
Subject:Permit Approved-Payment Due$81.00
PERMIT REVIEWED - PAYMENT DUE
Your permit application has been reviewed and is now ready for payment.Please login using the same registration information
used to apply and click"View my requests". Select your permit and press"Make Payment".
ER22-
000009
Type: Swimming Pool
Application 05/17/2022
Date:
Address: 1568 GARDENA AVE NE
New External 220V electric line from main panel to Hot Tub in the back yard.Installing 50 Amp breaker at main
panel.Outside disconnect GFCI box with 50 amp GFCI breaker will be placed at 4.5 feet from ground level and 7
Description: feet from Hot Tub.6 AWG cooper wire with THHN insulation will be used(2 hot, 1 neutral, 1 ground wire) .Line
will be inside of 3/4 inch PVC conduit tubing schedule 40 which will be attached to the eternal east wall at 1 foot
from ground level.The line from the GFCI Box to the Hot Tub will be buried inside of Metal conduit to 1 foot
depth and will meet the Hot Tub circuit panel from underneath(no exposure).
Applicant: Emiro Sangiovanni