Loading...
HomeMy WebLinkAboutA4 Reflective Plan - CodeReview 2021 IBC CODE INFORMATION BUILDING 'B' ® F3 PROJECT NAME: THE DWELLING PLACE I I o USE AND OCCUPANCY CLASSIFICATION: o LOCATION: FRIDLEY, MINNESOTA S-1 MODERATE-HAZARD STORAGE TOTAL = 400 SF (GROSS) ANOKA COUNTY OCCUPANCY LOAD (TABLE 1004.1.2) F�3 F1 I 1 1 APPLICABLE CODES: 'F1 F1 I I F1 I I 1. INTERNATIONAL BUILDING CODE 2021 EDITION 1. ACCESSORY STORAGE SPACE 2. INTERNATIONAL FIRE CODE 2021 EDITION 400 SQ.FT. (GROSS) ® 300 SQ.FT./OCCUPANT = 2 OCCUPANTS I1. 3. MINNESOTA STATE BUILDING CODE 2020 EDITION I I 4. MINNESOTA FIRE CODE 2020 EDITION I CONTINUOUS SOFFIT I `n TYPE OF CONSTRUCTION (TABLE 601) 2'-10 5 -4 5'-4" 2 -10 5. MINNESOTA ENERGY CODE 2020 EDITION TYPE VB WITHOUT AUTOMATIC SPRINKLER 6. FRIDLEY ZONING ORDINANCE CURRENT EDITION ( ) I ABOVE CABINETS i 1 LOCATION ON THE PROPERTY (TABLE 602) F1 _ I 1 1 BUILDING 'A' FIRE RESISTANCE RATING FOR EXTERIOR WALLS = 0 IF2 I I (EXTERIOR WALL FIRE SEPARATION DISTANCE 10< X <30 F1 LED LIGHTING I _ I FOLDING WALL TRACK USE AND OCCUPANCY CLASSIFICATION: UNDER O.H. CABINETS 1 1 B BUSINESS ALLOWABLE BUILDING HEIGHTS & AREAS (TABLE 503) 1n 1 2'-8" 5'-4" 5-14" v 'n 5'-4" 5' V 5'-4" V 2'-6" z SMALL ASSEMBLY SPACE (SECTION 303.1.2) 725 SF ALLOWABLE HEIGHT: ACTUAL HEIGHT: ACCESSORY STORAGE, MECHANICAL & TOILET 170 SF GROUP S-1 - 40 FEET (1-STORY) 8.5 FEET (1-STORY) ® I I I w o N TOTAL 895 SF (NET) ALLOWABLE AREA: ACTUAL AREA: F1 I 1 1 I a Q GROUP S-1 - 9,000 SQUARE FEET 400 SQUARE FEET I I z o a °z OCCUPANCY LOAD (TABLE 1004.1.2) BUILDING B F1 BUIL ,ING A 1 a ' SMALL ASSEMBLY SPACE AUTOMATIC SPRINKLER SYSTEM - NOT REQUIRED � Hw 725 SQ.FT. @ 15 SQ.FT./OCCUPANT = 48 OCCUPANTS `n `� x Q 2. ACCESSORY STORAGE, MECHANICAL & TOILET x a � ° 3 N 4'-0" 5'-4" I Z wi EXITING 1 I I �. oWw� o 170 SQ.FT. © 300 SQ.FT./OCCUPANT = 1 OCCUPANT I I I a �" N 1. NUMBER OF EXITS (TABLE 1015.1) F1 ® ® I F1 I � I MAXIMUM OCCUPANT LOAD = 49 OCCUPANTS S-1 OCCUPANCY: 29 OCCUPANTS = 1 EXIT REQUIRED - 2 EXITS PROVIDED "o d3 F3 1 1 I I F1 w o v 2. COMMON PATH OF EGRESS TRAVEL (TABLE 1014.3) w TYPE OF CONSTRUCTION (TABLE 601) � z WITHOUT SPRINKLER SYSTEM u u TYPE VB (WITHOUT AUTOMATIC SPRINKLER) S-1 OCCUPANCY: OCCUPANT LOAD < 30 = 100 FEET _ _ - - o Q a LOCATION ON THE PROPERTY (TABLE 602) 3. DISTANCE TO EXITS (TABLE 1016.2) WITHOUT SPRINKLER SYSTEM F4 GARAGE DOOR F4 GARAGE DOOR F4 GARAGE DOOR F4 GARAGE DOOR F4 FIRE RESISTANCE RATING FOR EXTERIOR WALLS = 0 S-1 OCCUPANCY: MAXIMUM DISTANCE 200 FEET TRAVEL DISTANCE - - (EXTERIOR WALL FIRE SEPARATION DISTANCE 10< X <30 4. MINIMUM EXIT DOOR WIDTH (IBC 1008.1.1) = 32" WIDE PER DOOR. W ALLOWABLE BUILDING HEIGHTS & AREAS (TABLE 503) ALL EXIT DOORS ARE MINIMUM 36" WIDE PER DOOR. REFLECTED CEILING PLAN SYMBOLS REFLECTED CEILING PLAN NOTES REFLECTED CEILING PLAN 5 N ALLOWABLE HEIGHT: ACTUAL HEIGHT: 5. DOOR SWING IBC 1008.1.2 A4 1/4" = 1'-0" GROUP B - 40 FEET (2-STORY) 8.5 FEET (1-STORY) EGRESS DOORS PERMITTED TO SWING IN WHERE OCCUPANCY LOAD FIXTURE LOCATION SYMBOL DESCRIPTION 1. ALL CEILING MOUNTED ITEMS SUCH AS LIGHT FIXTURES, GRILLES, ALLOWABLE AREA: ACTUAL AREA: IS LESS THAN 50. DIFFUSERS, SPEAKERS, EXIT LIGHTS, ETC., SHALL BE EQUALLY U 6" LED SPACED, UNLESS NOTED OTHERWISE. GROUP B - 9,000 SQUARE FEET 997 SQUARE FEET (GROSS) 6. DOOR OPERATIONS (IBC 1008.1.9) F1 GYP.BD. RECESSED o EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS CEILING FIXTURE 2. REFER TO MECHANICAL DRAWINGS FOR QUANTITY, SIZE AND TYPE Q� AUTOMATIC SPRINKLER SYSTEM - NOT REQUIRED SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. OF DIFFUSERS, RETURN AIR GRILLES, EXHAUST GRILLES, ETC. UNDER CONTINUOUS COORDINATE WITH LIGHTING LOCATIONS ON REFLECTED CEILING PLAN. ACCESSIBILITY F2 O.H.CABINETS STRIP LED p EXITING 1. BUILDING IS ACCESSIBLE LIGHT FIXTURE 3. FINISHED GYP BOARD SOFFITS SHALL EXTEND 1 BEYOND FACE AND U w EXPOSED ENDS OF WALL CABINETS AND FULL HEIGHT CABINETS. zz 1. NUMBER OF EXITS (TABLE 1015.1) 2. ROOF ACCESS - NONE REQUIRED. ROOF SOFFIT © 6" LED COORDINATE CABINET DIMENSIONS WITH SUPPLIER SHOP DRAWINGS. z B OCCUPANCY: 49 OCCUPANTS = 1 EXIT REQUIRED - 2 EXITS PROVIDED PLUMBING FIXTURES - NONE REQUIRED F3 ENTRANCE DOORS ® EXTER ORS FIXDTURE 4. VERIFY LOCATIONS OF ALL ELECTRICAL, COMPUTER, AND WIFI OUTLETS w w y ) WALL MOUNTED WITH OWNER. 2. COMMON PATH OF EGRESS TRAVEL (TABLE 1014.3 REQUIRED PARKING - NONE REQUIRED EXTERIOR U WITHOUT SPRINKLER SYSTEM F4 i EXTERIOR 5. INSTALL ALL FIRE AND SECURITY ALARMS AS REQUIRED BY BUILDING a GARAGE WALL CODE. B OCCUPANCY: OCCUPANT LOAD > 30 = 75 FEET LED FIXTURE P4 3. DISTANCE TO EXITS (TABLE 1016.2) WITHOUT SPRINKLER SYSTEM 8 B OCCUPANCY: MAXIMUM DISTANCE 200 FEET TRAVEL DISTANCE 4. MINIMUM EXIT DOOR WIDTH (IBC 1008.1.1) = 32" WIDE PER DOOR. ALL EXIT DOORS ARE MINIMUM 36" WIDE PER DOOR. 5. DOOR SWING (IBC 1008.1.2) 17'-4" 43'-4" 00 EGRESS DOORS PERMITTED TO SWING IN WHERE OCCUPANCY LOAD IS LESS THAN 50. - z 11'-0» CD oQ 6. DOOR OPERATIONS (IBC 1008.1.9) z I = EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS = N FOLDING WALL TRACK SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. [If o ACCESSIBILITY 1. BUILDING IS ACCESSIBLE 2. ROOF ACCESS - NONE REQUIRED. PLUMBING FIXTURES (IBC TABLE 2902.1) (2) 2 X 8 HEADER (2) 2 X 8 HEADER (2) 2 X 8 HEADER (2H 2 X 8 O REQUIRED TOTAL x w I OCCUPANCY B MEN & WOMEN PROVIDED 04 1. WATER CLOSET 1 1 1 (UNISEX) Lu 2. URINALS ui 0 0 0 y�O w RUSSE 3. LAVATORIES 1 1 1 (UNISEX) I 4. DRINKING FOUNTAIN 1 0 1 -0 1 -0 'p�, 0 2 -p I �Q Lli L s Qw OVERHANG OVERHANG `y 0'C' DOUBLE TRUSS ENTER D I w 5. SERVICE SINK 1 1 REQUIRED PROVIDED TOTAL ON FOLDING WALL TRACK I = w REQUIRED PARKING HANDICAP PARKING HANDICAP PARKING PARKING PROVIDED VER FY TR SS DESIGN W TH °OEGISTE ED ENGINEER I x W Q Q 4 1 (IBC-SEC.1106) 4 4 w N 0 Q [� w= w w= w= I w= Q �� o �� Q_ U) I N I o = N o of D N O N o RIDGE � N o w l w N x 4/12 SLOPE 4/12 SLOPE x 4/12 SLOPE I 4/12 SLOPE 2'-0" I 2'-07 » Q N N OVERHANG OVERHANG O El r� CIA �� a w `�`� o 1 RUSSE I ti�A U) 2'-0" I T w H wco xw CO N Q C3 w N N= I o 2) 2 X 12 EADER ( ) 2 X 12 H(ADER 2) 2 X 12 HEADER I (2) 2 X 12 HEADE � I o z Q BUILDING B C° w o < BUILDING A > N w O 1n/ r�RZF RN CHECKED �/V RWF 2 ROOF FRAMING PLAN DATE PROJECT NO. A4 5 N 5-12-2022 1/4" = 1'-0" 4 OF 4 SHEETS