HomeMy WebLinkAboutFinal Review 681 Glencoe St NE APPROVED
JensenD05/17/2022
SEPARATE PERMITS FOR: ELECT, PLUMB. MECH.
EXIST. ALDLN
4 CONSTRUCTION NOTES HOUSE
A102 /�
GENERAL
WORK SHALL CONFORM TO ALL STATE AND LOCAL BUILDING CODES, EXIST. AS SENTS
O CI 1TES
ORDINANCES, REGULATIONS, MANUFACTURER'S INSTRUCTIONS. ETC. GARAGE
2. ALL AREAS USED FOR STAGING, DUMPSTERS,CONTRACTOR PARKING, ETC. ARCHITECTURE
SHALL BE DESIGNATED BY OWNER.
SPHALT SHINdb IT I I I IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 IT 11 1 1 3. ALL AREAS OF THE JOBSITE MUST BE KEPT BROOM CLEAN. NO DEBRIS
SHALL BE LEFT ON SITE EXCEPT IN DESIGNATED AREAS. EXIST.
4. ACCESS TO ALL ENTRANCES AND EXITS MUST BE MAINTAINED IN AN GARAGE
ORDERLY AND SAFE MANNER.
5. DESIGN BUILD:
A. PLUMBING
B. ELECTRICAL Minneapolis, MN
6. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS BEFORE LG9388@gmail.com
ROOF BEARI NG BEGINNING CONSTRUCTION. NOTIFY OWNER OF ANY DISCREPANCIES. 763-300-2840
8' _ 111 7. PROVIDE FALL PROTECTION FOR WINDOW SILLS BELOW 36"AFF.
8. WINDOWS ARE GENERIC IN SIZES SPECIFIED ON DRAWINGS. SEE WINDOW
Tempered Glass per R308 N MANUFACTURER SPECIFICATIONS FOR ROUGH OPENING SIZES.
2020 IRC. 9. HEADERS ABOVE DOOR AND WINDOW OPENINGS IN WOOD FRAMED BEARING All Federal, State and local codes, ordinances,
WALLS ARE 2-2X10 UNLESS NOTED OTHERWISE. EXIST. regulations and manufacturer's instructions,
d 10. ALL BEARING WALLS TO HAVE DOUBLE TOP PLATES. ALL BUILDING LOADS AND GARAGE etc. shall be considered as art of the
STRUCTURAL MEMBERS TO BE VERIFIED AND SIZED BY MATERIAL SUPPLIER. p
Smoke detectors in each 11. ALL STRUCTURAL LUMBER TO BE SOUTHERN YELLOW PINE GRADE A OR EQUAL. specifications for this building and shall take
00 COMPOSITE LAP SIDING sleeping room and on each level 12. FRAMING:ALL EXTERIOR WALL FRAMING SHALL INCLUDE 1/2"CDX PLYWD. precedence over anything shown, described
13. SHEATHING.SHEATHING IS FLUSH TO OUTSIDE FACE OF FOUNDATION WALL. or implied where same are at variance.
CDEl LIE of the house per R314 14. TRUSS SUPPLIER: IF ROOF AND FLOOR TRUSS LAYOUTS DIFFER FROM WHAT IS
SH
OWN ON PLANS,NOTIFY THE GENERAL CONTRACTOR TO VERIFY ADEQUATE Contractor is responsible for determining and
BEARING CONDITIONS AT ALL AFFECTED FRAMING AND FOUNDATION LOCATIONS. ensuring compliance with all applicable codes
and manufacturer's requirements.
ID
-- FIRST FLOOR THE SUBTRADES WILL BE RESPONSIBLE FOR THE COMPLETE DESIGN OF THEIR
0 _ 0 SCOPE OF WORK.ALL DESIGN AND COSTS FOR THE WORK SHALL BE PRESENTED
' 11 TO THE OWNER FOR APPROVAL PRIOR TO COMMENCEMENT OF WORK.
Provide treated bottom plates in THESE SUBTRADES ARE RESPONSIBLE FOR ALL CONSTRUCTION
Anchor bolts: min 7" embedded in concrete p DOCUMENTATIONAND PERMITS REQUIRED TO COMPLETE THEIR WORK.
Min. 6" clearance from basements and proper sized framing THESE SUBTRADES ARE RESPONSIBLE FOR ALL COORDINATION WITH RELATED 44'-4 1/2" (VERIFY)
min 2 per sill, min. 12 from plate ends, min. p p g TRADES WHEN THE SCOPE OF WORK OVERLAPS, I.E. HVAC WILL PROVIDE
framing/siding to ground. nails. SUFFICIENT COORDINATION WITH ELECTRIAL SUBCONTRACTORS SO THAT ALL PROPOSED EXISTING HOUSE
WORK AND CODES NECESSARY TO COMPLETE THIS WORK ARE INCLUDED IN THE - DDITION/ '
CO detection per R315 PROJECT COST. EXIST.
THESE SUBTRADES MUST ENSURE THAT ALL WORK IS COMPLETED ACCORDING TO HOUSE
2020 IRC. ALL CODES ENFORCED IN THE JURISDICTION OF THE PROJECT. r in
Min. ceiling height in .
basements 6'-4" BASEMENT
— - - -7' - 8" w
n SOUTH ELEVATION
1/4" = V-0" 60 °U
Z
Lu
' N �
w �
� w
GLENCOE STREET NE Z
V)
--== Z
_---_
SITE PLAN 02
1" = 20'-0" NORTH
■ - U ..
Z >
`l1
LL
EXIST.STAIRS 32"X80"DR. N II II
I I I I I
I I I I DN I I II I II I
EXIST.WALLS UPI II
I II II I
DN DN II II y
-- -- ---
cc --
20' 8" 13' 41/2" (VERIFY) - ------ BENCH W/ � -----
WH
------ HOOKS "' ----- FURN.
x
CID
15'-3" 5'-5" 3'-4" 6'-6" 3'-61/2" ------ iv -----
M =
32°x8o°DR. X� 4 EXIST. BASEMENT
4 Cl)(0
_ _ A102
20'-8"
A102 NEW WALL(TYP.) 36"X64"SH EGRESS r
6'-8"HD. HT. o I � W D
LID
PERMIT SET
CD , 7 60"X64"SH DBL. 60"X64"SH DBL. REF. - 00
6'8"HD.HT. 6'8"HD.HT. 1- - - - - - - - - - - - - - - - - - �
16"" _. 8'-6' 3 1/2" 2, 0" 3 1/2" 8'-6", ° z
OWELL 6"
TO
r _ 2 1.75"x7.5"LVL HDR., 2-1.75"x7.5"LVL HDR. ° _ FDOUND WALL W/#5I@
In cn ¢ ; ' KITCHEN ° 12"VERT. (TYP.)
LID w } 8'0"CLG. Cl)CD w
a[ m EXIST.WALLS L- > 8" 19' 4"
w BEDROOM 2r o BEDROOM 3 ,
O C7 DW
__ � 8'-0"CLG. - 8'-0"CLG. o Z N
�o -I, °' O < + - M
Z iD co
M� LIVING ROOM
� � o I 8' 0"CLG. j 4"REINF. CONC. SLAB W/10/10
c9� WWM W/6 MIL. VAPOR BARRIER
N +80 CID
N N ON 2"T-250 INSUL.ON 2500 PSF
Cl) 60"X80"BYPASS Q T MIN.SOIL(TYP.)
9 0 C 31/2" 10'-11/2" ORIGINAL ISSUE: 04/01/22
_ S.D.
T ' EXISTING FOUNDATION
N c Q REVISIONS
co
r w o M ' Foundation walls with reinforcement per
N R404.1 .1 8" 2020 IRC.
No . Description Date
cc
o LINEN = -�
cU oo r EXIST.WALLS
_ O' co x DINING ROOM
oC 2' 3" 3 1/2 N ao m Z
N N co
8'-0"CLG. N
T Z 28"X80"DR. N cD= 8"REINF. CONC. BLK.WALL ON
_w MASTER BEDROOM 5'-1'��_� :31/2" �2'-0" 3�1/2" � � � �9 1 x
- 8'-0"CLG. o �o 20"X10"5,000 PSI CONC. FTG.W/
N 2#5 BOTT.CONT. (TYP.)
BATHco DOWELL 6"INTO EXIST.
EXIST. � N EXIST.WALLS m FOUND.WALL W/#5 @
6„ 13' 6" 31/2" X 8�O • - r 12 VERT. (TYP.)
— — 28"X80"DR.
- - • , Project Number
2-1.75"x7.5"LVL HDR. M ih 2 1.75"x7.5'LVL HDR.
0o C1 PROJECT NUMBER
60"X64"SH D L. EGRESS 36"X48"SH 60"X64"SH DBL.
6'-8"HD.HT. m 6'-8"HD.HT. 6'-8"HD.HT. — — — — —
NEW REINF.8"CONC.BLK.
N m mp. gla s, ml - 4"REINF. CONC. SLAB W/10/10 FOUND.WALL ON20"X10" Author Checker
111 to — of II"I•
pO ('H XI N N WWM W/6 MIL.VAPOR BARRIER CONC.FTG.W/2#5CONT. DRAWN BY CHECKED BY
r iN r Rv - NI• r ON 2500 PSF MIN.SOIL(TYP.)
LIDCID Cq
O
6'-0 1/2" 3'-8" 2" 171/2"' 9'-6 1/2" LID
N ' 1' 3 1/2" 7 1/2 3'-1" , 4'-9 1/2" 2'-11 1/2""7 1/2" 6'-7 1/2" -'4' 2 1/2" 7 11/2"I 2" CO TROTT-
BINNS
=--= 3-2X10 BM. _=-'-'= ---==� - _�=-3 2X10 BM.-=== --` -== --==---3-2X10 BM.�= — — — — — — — — — — — — — — — — — — — — — — — — — — CONSTRUCTION. LLC
_ _ _ _ _ _
8X8 P.T.W D. POST(TYP.) --
a 9'-8" 10'-4" 25'-0" (VERIFY) 9'-8" 10'-4" 25'-0"
45' 0" (VERIFY)00 45'-0" PLANS
r,
N
FIRST FLOOR 1 ,092 S.F. FOUNDATION
3 1/4" = 1'-0" 2 1/4" = 1'-0"