Loading...
HomeMy WebLinkAbout16 x 72 201 PLEASE VERIFY I-BEAM SPREAD AND HOUSE MEASUREMENTS. PIERS ARE NOT REQUIRED AT 36" EXTERIOR DOORS WHEN "PIER SAVERS" ARE UTILIZED. 68'-0"HOME LENGTH 27'-5" T-0" 24'-0"GAS INLET 2'-0"WATER 36-2"ELECT. DROP —7 1'-0"WATER INLET 1'-0"GAS INLET+ V-8"ELEC DROP INTERMEDIATE PIERS wiv SPACING PER INSTALL MANUAL TYPICAL UNIT 5'4" g QUANTITY PER INSTALL MANUAL I-BEAM DRAIN O FOOTER SIZE PER INSTALL MANUAL LOCATION DROP _ I --- tDITIONALOCKING SEE NOTE 2 BELOW 99 1/2" 3'-0" 20'-9"(19'-6"W/2 BED OPT.) AXLE 24'-2"DRAIN DROP SPREAD 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'4" 8'4" PIER SPACING IS FOR ILLUSTRATION ONLY. IMPORTANT: When a home is ordered with an optional 80"frame, the frame will be inset from sidewalls and ACTUAL PIER SPACING SHOULD BE DETERMINED mating walls 51". VERIFY measurements before starting foundation design. USING THE INSTALLATION MANUAL 1) THE MANUFACTURER ASSUMES NO RESPONSIBILITY FOR ACTUAL 5) IT WILL BE THE RESPONSIBILITY OF THE SITE CONTRACTOR FOUNDATION DESIGN AND CONSTRUCTION. TO VERIFY THE PROPER LOCATION OF COLUMN SUPPORT PERMANENT FOUNDATIONS:CHECK LOCAL BUILDING CODES AND REGULATIONS 2) ADDITIONAL BLOCKING IS REQUIRED AT EACH SIDE OF EXTERIOR BLOCKING AND TO VERIFY THE PROPER MATING LINE GROWTH AND CONSULT A REGISTERED PROFESSIONAL OR STRUCTURAL ENGINEER WHEN DOORS AND AT EACH SIDE OF SIDEWALL OPENINGS GREATER THAN 4 DIMENSIONS BASED UPON ACTUAL SITE CONDITIONS AND YOU ARE SITING YOUR HOME ON A PERMANENT FOUNDATION(SUCH AS A FULL FEET IN WIDTH(I.E.,PATIO DOORS,PICTURE WINDOWS,ETC.). REQUIREMENTS(DOUBLE WIDES ONLY). BASEMENT,CRAWL SPACE,OR LOAD BEARING PERIMETER FOUNDATION). 3) FOR PIER REQUIREMENTS AT ENDWALL SEE FIGURE 8 IN THE 6) ALLOW 1/2"AT MATING LINE FOR MATE UP GROWTH. INSTALLATION MANUAL. 7) SEE SET-UP AND INSTALLATION MANUAL FOR PERIMETER 4) ALL DWV,PLUMBING,GAS SUPPLY,ETC.,DIMENSIONS ON PRINT BLOCKING REQUIREMENTS. MAY BE+OR-12". MANUFACTURER DISCLAIMER NOTICE:(THIS PIER PRINT IS FOR HOMES PRODUCED ON OR AFTER JUNE 1ST 2006) PLEASE READ AND UNDERSTAND THE FOLLOWING INFORMATION.THE MANUFACTURER DOES NOT DO FOUNDATION INSTALLATION OF HOMES. IT WILL BE THE RESPONSIBILITY OF THE DEALER/SITE CONTRACTOR TO INSURE THAT ALL SITE WORK WILL CORRELATE WITH THE UNIT MODEL NO. MANUFACTURER DATE: ORDERED. 1672 201 1-21-2011 NOTICE O HOME INSTALLERS:MANUFACTURED HOMES WEIGH SEVERAL TONS.DO NOT ATTEMPT TO INSTALL ANY O �LC�fZL�%LLLL 1OO REV: HAVING EXPERIENCE,ENCE,KNOWLEDGE,AND UNDERSTANDING OF ALL INSTALLATION REQUIREMENTS.FAILURE TO MEET REQUIREMENTS TE WITHOUT DRAWING NO. QUIREM NTS _ PB 1672 201 1/24/2019 MAY RESULT IN SERIOUS INJURY OR DEATH TO AN INEXPERIENCED INSTALLER.INSTALLERS:PLEASE READ AND UNDERSTAND THE SET-UP AND INSTALLATION MANUAL SUPPLIED WITH THE HOME BEFORE ATTEMPTING ANY INSTALLATION OF ANY MANUFACTURED HOME.