HomeMy WebLinkAboutFinal review; 7381 Jackson street GENERAL NOTES SHEET INDEX SITE MAP &PV LAYOUT PV 1.0 CONTRACTOR 1. All electrical materials shall be new and listed by recognized I HEREBY CERTIFY THAT THIS PLAN, WOLFRIVER ELECTRICAL 1-LINE DIAGRAM PV 2.0 SPECIFICATION, OR REPORT WAS PREPARED Address:101 Isanti Parkway electrical testing laboratory SYSTEM LABELING DETAIL PV 3.1 BY ME OR UNDER MY DIRECT SUPERVISION NE, Isanti, MN 55040 Custom made equipment shall have complete test data submitted PLACARD PV 3.2 AND THAT I AM A DULY LICENSED Phone number: (763)229-6662 0ELECTRIC by the manufacturer attesting to its safety PROPERTY PLAN PV 4.0 PROFESSIONAL ENGINEER UNDER THE LAWS E-mail: contactCd_)wolfriverelectric.com 2. Outdoor equipment shall be NEMA 3R rated or equivalent ATTACHMENT LAYOUT PV 5.1 OF THE STAT NESOTA. Xcel Energy Application#05125633 3. All metallic equipment shall be grounded ATTACHMENT DETAIL PV 5.2 4. Contractor shall obtain electrical permits prior to installation and INVERTER DATA SHEET D 6.0 SIGNATURE: shall coordinate all inspections, testing commissioning and NAME: MANOUCHEHR HAKH ANESHI Owner: Larry G Noble acceptance with the client, ENPHASE RAPID SHUTDOWN p 7 p Property Address: 7381 Jackson St NE Fridley, MN 55432 DATE:_ _ICENSE NUMBER: 58681 Pro Type:utility co. and city inspectors as needed. MODULE DATA SHEET D 8.0 Property yp : Single Family Residence 5. The electrical contractor shall verify the exact locations of service RACKING DATA SHEET Drawn by: New@engineeri D 9.0 Date Certified and Date: 06/13/202 2 points and service sizes with the serving utility company and ATTACHMENT DATA SHEET Signed: 06/17/2022 comply th ility es 6. Drawings/areldiatgrammatic o/nlyrro routing of raceways shall be ENPHASE AC COMAO-P-Rd 1 V E D VICINITY MAP (SCALE: NTS) option of the contractor unless otherwise noted and shall be INVERTER CERTIFICATION D 12.0 coordinated with other trades. SURGE PROTECTION Ionconr)06A29/2022 7. If the roof material or the roof structure not adequate for PV WITNESS TEST PROCEDURE D 14.0 Co mrt°Cw°NE Cm ert°Cumn NE installation, call the engineer of record print to installation. The PV INSPECTION CHECKLIST-D 15.0 R contractor is responsible to verify that the roof is capable of withstanding the extra weight. GOVERNING CODES m 8. If the distances for cable runs are different than shown, the contractor shall notify the electrical engineer to validate the wire THE INSTALLATION OF SOLAR ARRAYS AND m - size. Final drawings will be red-lined and updated as appropriate. PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH 9. Whenever a discrepancy in quality of equipment arises on the THE FOLLOWING CODES: drawing or specifications, the contractor shall be responsible for • 2020 National Electrical Code M°^°"""` "�"°"tt providing and installing all materials and services required by the • 2018 International Building Code strictest conditions noted on the drawings or in the specifications • 2018 International Residential Code astayHon 5 3e,,,ks°n5 NE • 2020 Minnesota Residential Code •Frldley MN 5562,USA e to ensure complete compliance and longevity of the operable m � system required by the engineer of record. • 2020 Minnesota Building Code m • 2020 Minnesota Energy Code s • 2020 Minnesota Accessibility Code m PHOTOVOLTAIC NOTES • 2020 Minnesota State Fire Code • 2018 International Fire Code • 2018 International Energy Conservation Code 1. Rooftop mounted photovoltaic panels and modules shall be tested, . 2018 Mechanical Code listed and identified by recognized testing laboratory AS ADOPTED BY THE STATE OF MINNESOTA 2. Solar system shall not cover any plumbing or mechanical vents ALL OTHER ORDINANCE ADOPTED BY THE 3. Modules and support structures shall be grounded unless racking has integrated ground. LOCAL GOVERNING AGENCIES 4. Removal of an interactive inverter or other equipment shall not SYSTEM RATING SATELLITE VIEW (SCALE: NTS) disconnect the bonding connection between the grounding electrode conductor and the photovoltaic source and/or output DC 14.00 KW STC circuit grounded conductors. AC 10.15 KW STC 5. All PV modules and associated equipment and wiring shall be protected from physical damage. EQUIPMEN I SUMMARY 6. Live parts of PV source circuits and PV output circuits over 150v to 35 HANWHA 400 WATT MODULES ground shall not be accessible to other than qualified persons while energized. WITH IQ8+ MICROINVERTERS 7. Inverter is equipped with integrated DC disconnect, thus providing ground fault protection ECTRICAL INFORMATION 8. All conductors shall be copper and 75 deg rated 9. A single conductor shall be permitted to be used to perform the EXISTING multiple functions of do grounding, AC grounding and bonding MAIN SERVICE PANEL BUS SIZE:150A between AC and DC systems. MAIN SERVICE BREAKER SIZE:150A 10.Non-current carrying metal parts of equipment shall be effectively MOUNTING SYSTEM: SNAPNRACK bonded together. Bond both ends of raceways. BUILDING INFORMATION CNGINCCr"4INC CONSTRUCTION TYPE: V-B Engineerinc.io, OCCUPANCY: R3 303 N Glenoaks Blvd ROOF:COMP SHINGLE Burbank, CA 91502 Truss 2 x 4 @ 24" O.C. (747) 333-5991 new(cDengineerinc.io N INDEX SECONDARY INTERCONNECTION o° MSP (E)150A Main Service Panel n MM........................(E) Main Meter m — ECB....(N) Enphase Combiner Box W lJ �Q E AC.................... (N)60A Utility AC HE Memory LY m Total Roof Area:1598 Total Module Area:770 270 • go, JB.......................(N)Junction Box Q •738,Jackson 32U 48.18% of Coverage ........................(N) Microinverter vCarestay Homes Fridle MN 5432 USA D Webitality m Solar Module m p NOTE:A 36-inchwide pathway m shall be provided to the emergency EMT type Conduit a escape and rescue opening. 180° ............. Fire Setback Line *Roof access is not located in areas that SCALE: 1/16" = 1'-0" 4 m require placement of ground ladders over FMT type Conduit m exterior wall openings(R324.6.1) Madsen Park SOLAR MODULES Avail Academy© m 35 HANWHA 400 Watt -High School _ C Ra.,_ Model#Q.PEAK DUO BLK ML-G10+ 73rd""e"E INVERTER 73rd Ave NE lard Ave NE 73rd Ave NE 73rd Ave NE 73 rd Ave NE INVERTER TYPE: Micro: 35 EnphaselQ8PLUS Model#IQ8PLUS-72-2-US(240V) Roof Access Solar PV Array 3 CONTRACTOR EQUIPMENT ELEVATION 7-Hanwha 400 W Modules 7-IQ8+Microinverters Pitch:20 Deg Orientation: 180 Deg ❑ ❑ ❑ ❑ ❑ ❑ _ 18"firesetback WOL�RIVER ❑ ❑ ° ELECTRIC Q N o"_ =o ❑ ❑ ❑ ❑ ❑ JB4 e�ro% Xcel Energy Application#05125633 From roof Solar PV Array 3 ° JB3 13 ❑ « 3-Hanwha 400 W Modules I� Main 10� w 3-IQ8+Microinverters y m ❑ a ° a ECB Meter Utility AC z Pitch:20 Deg C ❑ ❑ a1*=AN DISCONNECT LOCKABLE Wolf River Electirc Main Disconnect �' Orientation: 180 De L a EADLY ACCESSIBLE Service o Address:101 Isanti Parkway rn ° ° r. ° a ° a NE, Isanti, MN 55040 Panel oii EOB o MSP Phone number: (763)229-6662 r= o ° a ❑ b JB1 E-mail:contact�wolfriverelectric.com JB2 ° a ❑ b ❑ 3"fire setback Lj ❑ a ° b Solar PV Array 1 �� ❑ ❑ a ° b 19-Hanwha W Modules SITE MAP & PV � b b b o 19-IQ8+Microinverters oinverters I ° b ❑ b Pitch:20 Deg LAYOUT Orientation:90 De Solar PV Array 2 ENGINEER INC 6-Hanwha 400 W Modules 6-IQ8+Microinverters Drawn by:New@engineerinc.io Pitch:20 Deg DATE:0611312022 NOTE: No clearance issue Orientation: 180 Deg Project Name Distance between all equipments is maximum 10" Larry G Noble Property Adress: Xcel Energy Application#05125633 7381 Jackson St NE Note: 24/ 7 Unescorted keyless access is to be Fridley, MN 55432 provided for ALL UTILITY EQUIPMENT Project Scale: NOTE: Conduit in attic shall PV SYSTEM AS INDICATED be minimum 18 inches from roof sheating EPV 1 .0 EFERENCE POINT OF APPLICABILITY NOTE: Service Panel does not contain center fed Main Breaker: SECONDARY INTERCONNECTION R MAIN METER 120/240V, 0 1 P,3W 7.26A w21 ( _ J BOX2NEMA3Rm - + ENPHASE IQ COMBINER4 Su I Side Ta 0 0000� 00 0000 120/24OV, NEMA 3R PV MONITORING DEVICE z Z) 00 0000Q V00 000000 0000 2 #14 AWG THWN/THWN-200 0000 60A FUSED AC DISCONNECTNON CENTER 150A 00 6�000 1 OA 2-POLE WITH 60A FUSES, 7.26A UTILITY AC DISCONNECT VISIBLE-OPEN MAIN C/B LOCKABLE,READILY ACCESSIBLE NEMA3R m - - - + INSTALL 3 20A PV 120/240V 1 P 3W (3)#6AWG THWN/THWN-2 x ❑00❑ 0000 0000 (6)#10 AWG THWN/THWN-2 ( ) U _ 0000 0000 0000 2-POLE C/B (1)#6 AWG GND z Z) 0000 0000 0000 (1)#8 AWG GND U 0000 0000 0000 3/4"EMT 2 FEET of Of 0000 0000 0000 3/4"EMT 7 FEET EXISTING m - 100❑ 0000 0000 150A MAIN U 1-,000 2-,000 6-,000 42.35A SERVICE 42.35A 15.73 a PANEL J eoxi �1 120/240V, NEMA3R _ 1 ' oc0 0000 v 1 P,3W x ¢ 0000 0000 0000 � U � 0000 0000 0000 z Z) 0000 0000 0000 Surge Protection Q V 0000 0000 0000 0000 0000 0000 MNSPD-300-AC m - 0000 0000 0000 _ (NEW)GEC o U '1000 '1000 000 = 1 2 3 (3)#6AWG THWN/THWN-2 7\\\Add Ground rod and 0 (6)#10 AWG THWN/THWN-2 0 3.63A (1)#8 AWG GND (1)#6 AWG GND tie it to the existin round rod. J BOX3 3/4"EMT 2 FEET - - = NEMA3R 3/4"FMT 20 FEET GEC x U ❑00❑ 0000 0000 1 #6 AWG GND = (E)GROUNDING U ❑00❑ 0000 0000 In locations where there is no local Public Authority, the customer is exempt from ELECTRODE SYSTEM z Z) 000❑ 0000 0000 Q 0 0000 0000 0000 inspection, and/or the service has been shut off or disconnected for more than 365 days (1 year), 0000 0000 0000 CONTRACTOR m 1'O1000 2�000000 3-°i000000 the licensed electrician orwireman shall submit a signed and dated Xcel Energy Electrical 12.1A Inspection Certificate to the Company's Builders Call Line attestingthat the electrical installation 35 ENPHASHANWHE 400 WATT MODULES p 35 ENPHASE IQ8PLUS MICROINVERTERS NEM 3R has been completed and installed according to the current National Electrical Code@, the Xcel ENPHASE IQ8PLUS MICROINVERTERS Energy Standard for Electric Installation and Use, and any other applicable codes that apply before 1 PHASE 290VA �/IpLRIVER UWTJ� - MAXIMUM OUTPUT CURRENT 1.21A 0 0000U 0 0000 a ectrlc service Is energize AC PORT BACKFEED CURRENT OAz Z) 0 000o ELECTRIC Q U0 0000 ENPHASE Q CABLE NOTE:AC DISCONNECT VISIBLE AND LOCKABLE DC SHORT CIRCUIT CURRENT 15A 00 0000 00 0000 (2)#12 AWG PV WIRE pp00 7�000 (1)#6 AWG EGC Xcel EnergyApplication#05125633 FREE IN THE AIR SYSTEM RATING AND DER POWER OUTPUT PV ARRAYRATING WIRE SIZE CALCULATION DC 14.00 KW STC BRANCH CIRCUIT-A BRANCH CIRCUIT-A AC 10.15 KW STC Wolf River Electirc INVERTER:ENPHASEIQ7PLUS-72-2-US Number Modules 13 Type Q.PEAK DUO BLKML-G10+ jHanwho400Watt Number OF Microinverters in Circuit 13 Address:1011santiParkway INVERTER MAXIMUM CONTINUOUS OUTPUT:290VA Number Micro Inverters 13 IType EnphoselQ8+Microinverters IQ8PLUS-72-2-US(240V) Microinverter Maximum Output Current (A) 1.21 NE, Isanti, MN 55040 SYSTEM POWER OUTPUT:35 x 290=10.15 Total DC Wattage(Watts) Watts STC,(Watts/Module)13*400=5200 Branch Circuit Total Current (A) 13*1.21*1.25=19.66 Phone number: (763)229-6662 Array Currents I-SC 1 11.14 JA I-MP 1 10.77 JA Breaker Size Per Branch Circuit(A) 20 E-mail:contact(a)_wolfriyerelectric.com Module Voltage V-OC 1 45.3 V V-MP 37.13 1 V BRANCH CIRCUIT-B BRANCH CIRCUIT -B Number Modules 12 IType Q.PEAK DUO BLKML-G10+ Hanwho 400 Watt Number OF Microinverters in Circuit 12 Number Micro Inverters 12 IType EnphoselQ8+Microinverters IQ8PLUS-72-2-US(24OV) Microinverter Maximum Output Current (A) 1.21 ELECTRICAL 1-LINE Total DC Wattage(Watts) Watts STC,(Watts/Module)12*400=4800 Branch Circuit Total Current (A) 12*1.21*1.25=18.15 DIAGRAM Array Currents I-SC 11.14 JA I I-MP I la77 1 A Breaker Size Per Branch Circuit(A) 20 Module Voltage V-OC 45.3 1 V V-MP 37.13 1 V BRANCH CIRCUIT -C BRANCH CIRCUIT -C Number Modules 10 Type Q.PEAK DUO BLK ML-G10+ Hanwha 400 Watt Number OF Microinverters in Circuit 10 Number Microinverters 10 IType EnphaselQ8+Microinverters IQ8PLUS-72-2-US(240V) Microinverter Maximum Output Current (A) 1.21 ENGI NEE r-ZINC Total DC Wattage(Watts) Watts STC,(Watts/Module)10*400=4000 Branch Circuit Total Current (A) 10*1.21*1.25=15.13 Drawn by.New@engineerinc.io Array Currents I-SC 1 11.14 JA I-MP 1 10.77 JA Breaker Size Per Branch Circuit(A) 20 I DATE:O6/1312022 Module Voltage V-OC 1 45.3 1 V V-MP 37.13 1 V Project Name: FROM JBOX TO ENPHASE COMBINER BOX Larry G Noble Xcel Energy Application#05125633 Maximum Con tinius Current(A) 1 18.15 1 More Than 3 CCC Adjist.Factor 0.8 Adjusted Conductor Amp acity(A) 18.15/0.8=22.69 Property Adress: Note: 24/7 Unescorted keyless access is to be Raceway Height From Roof(Temp 39+22=61C)131/2" #of wire(#BC*2) 1 6 Ambiend TernFactor Per NEC Table 310.15(b)(2)(a) 0.71 7381 Jackson St NE provided for ALL UTILITY EQUIPMENT Temp.Derate Factor(max.continous current divided ambient tem.Factor(A) 22.69* Fridley, MN 55432 0.71=31.95 Wire Size from NEC Table 310.15(b)16 10AWG y FROM ENPHASE COMBINER BOX TO MAIN PANEL Protect: I Scale: Design meet National Electric COde(NEC codes) Total Number Of Microinverters 35 TotalAmpsFromAllMicroinverters (AJ 35*1.21=42.35 Consider Continuous (AJ 42.35*1.25=52.9375 PV SYSTEM AS INDICATED DC 14.00 KW STC Temp.Derate Factor(0.91 at wall of the Building)(A) 52.9375/0.91=58.17 Wire Size from NEC Table 310.15(b)16 6AWG ��\ / .O AC 10.15 KW STC Ambiend Tem Factor Per NEC Table 310.15(b)(2)(o) 0.91 V WARNING NOMINAL OPERATING AC VOLTAGE � NOMINAL OPERATING AC FREQUANCY � TURN OF PHOTOVOLTAIC MAXIMUM AC POWER � AC DISCONNECT PRIOR TO MAXIMUM AC CURRENT � WORKING INSIDE PANEL MAXOCERCURRENTDEVICERATING - FOR AC MODULE PROTECTION PV ARRAY Photovoltaic Power Source DO NOT DISCONNECT PV SYSTEM DC DISCONNECT © UNDER LOAD — OPERATING CURRENT • OPERATING VOLTAGE - CAUTION: SOLAR CIRCUIT MAXIMUM SYSTEM VOLTAGE - MAIN PV SYSTEM SHORT CIRCUIT CURRENT - DISCONNECT © WARNINGLABEL10 LABEL20 © ECTRIC SHOCK HAZARD© MAIN PV SYSTEM RATED MAX POWER-FONT CURRENT � PV SUB-PANEL RATED MAX POWER-FONT VOLTAGE � HE DC CONDUCTORS OF THIS AC DISCONNECT MAXIMUM SYSTEM VOLTAGE PHOTOVOLTAIC SYSTEM ARE SHORT CIRCUIT CURRENT � O UNDE,lei ROUNDAND MAY BE ENERGIZED LABEL11MAX RATED OUTPUT CURRENT OF - THE CHARGE CONTROLLER IF INSTALLED © SOLAR DISCONNECT WARNING © ELECTRIC SHOCK HAZARD CAUTIONSOLAR PV SYSTEM EQUIPPED WITH CONTRACTOR DISCONNECTIF GROUND FAULT IS INDICATED SOLAR ELECTRIC SYSTEM RAPID SHUTDOWN ® NORMALLY GROUNDED CONDUCTORS CONNECTED MAY BE UNDERGROUND AND ENERGIZEDTURN RAPID SHUTDOWN LABEL 13 SWITCH TO THE • POSITION TO • SHUT WN PV SYSTEM —.20ELECTRIC WARNING-DUAL POWER SOURCE • D REDUCE © SECOND SOURCE IS PV SYSTEMSHOCK WARNING EnergyIN THE ARRAY. 05125633 © ELECTRIC SHOCK HAZARD LABEL 14 CAUTION BielNOT TOUCH =1Ile1 PHOTOVOLTAIC SYSTEM CIRCUIT TERMINALS ON BOTH LINE AND LOAD IS BACKFEDWolf River Electirc SIDES MAY BE ENERGIZED IN THE OPEN '•• - • POSITIONLABEL 15 NE, Isanti, MN 55040 MAIN SERVICE Phone number: PANEL E-mail: - � _ _ _ PHOTOVOLTAIC AC DISCONNECT • ® LABEL.6MAXIMUM AC OPERATING CURRENT O � O WARNING © MAXIMUM AC OPERATING CURRENT ELECTRIC SHOCK HAZARDLABEL 16 SYSTEM LABELING DETAIL DO NOT TOUCH TERMINALS PHOTOVOLTAIC TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION UTILITY AC DISCONNECT DC VOLTAGE IS ALWAYS PRESENTLABEL 17 Drawn , _ __ WHEN SOLAR MODULES D. 06 mject Name Larry G ARE EXPOSED TO SUNLIGHT PHOTOVOLTAIC Noble 7381 Jackson St NE DC DISCONNECTFridley, Note: C 690 PV SYSTEM AS INDICATED CAUTION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: DISCONNECTS LOCATED AS SHOWN: SERVICE 1 OF 2 SERVICE 2 OF 2 CONTRACTOR ❑ ❑ ❑ ❑ ❑ ❑ SOLAR PV ARRAY ❑ ❑ ❑ ❑ SOLAR PV ARRAY WOL�RIVER 7v❑ ❑ ELECTRIC ° ENPHASE COMBINER BOX ENPHASE COMBINER BOX Xcel Energy Application#05125633 PV SYSTEM DISCONNECT ° PV SYSTEM DISCONNECT ° °FOR UTILITY OPERATION ° FOR UTILITY OPERATION Wolf River Electirc ° o SERVICE POINT & ° oT SERVICE POINT & Address:101 Isanti Parkway ° UTILITY METERING ° UTILITY METERING NE, Isanti, MN 55040 Phone number: (763)229-6662 E-mail: ;ontact(awolfriverelectric.com U U ° ° N ° N ° ° W \ E W E PLACARD L) 7381 Jackson St NE S 7381 Jackson St NE S ENGINEEr-:ZINC Drawn Fridley, MN 55432 Fridley, MN 55432 DATE 06�312022gineerinc.io Project Name: Larry G Noble Property Adr- 7381 Jackson St NE Fridley, MN 55432 Project: Scale: PV SYSTEM AS INDICATED PV 3.2 N 0° LEGEND Q MSP................ Main Service Panel MM........................ Main Meter D i AC .............Utility AC Disconnect W 0� E CNGI NCC�1 NC ECB..........Enphase Combiner Box 270 Q a� s°° 303 IN Grin oa U o D Burbank,N GCA 9 s Blvd Bur , -5 9 502 (747)333 5991 S newa-engineerinc.io 180° SCALE: 1/16" = T-0" Q ((�� Q Q � PROPERTY`LINE � 128'-2" 1 HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED 000 0 Q o o BY ME OR UNDER MY DIRECT SUPERVISION a AND THAT I AM A DULY LICENSED 0 0 ® Q� Q 0 • ®e •� PROFESSIONAL ENGINEER UNDER THE LAWS v • •• v ' OF THE STAT NESOTA. d • ' Q SIGNATURE: 3 NAME: MANOUCHEHR HAKH ANESHI ®• \`', �,• ' e o '• s 0 0 •• DATE:_ _ICENSE NUMBER: 58681 O • o • 0 � ' 0 Date Certified and ,•� �� Signed: 06/17/2022 o ❑ o -� •°' o •�e CONTRACTOR w o ••' ee Ell . ® o •e Z I O � � • • ' • O Q e HT o 0 00 .. 6-1" WOLF RIVER 0 �� o ' / 0 �0 13 EC13 o O ELECTRIC • U ; AC Q O Xcel Energy Application#05125633 ' o p • ems;` p MSP� o 0 0 D o 0 o Wolf River Electirc ❑ ❑ o 13 • Address:101 Isanti Parkway d : > NE, Isanti, MN 55040 i Driveway o ���' OI Phone number. 229-6662 E-mail:contact(a�D_wol wolfriverelectric.com u • 44'-11" _� _ • o - tea- 9' Q PROPERTY PLAN ® ... 128'-2" , 0 ENGINEEr-4INC Drawn by.New@engineerinc.io DATE:0611312022 Project Name: Larry G Noble Property Adre- 7381 Jackson St NE Fridley, MN 55432 Xcel Energy Application#05125633 [ PVcSYSTEM AS INDICATED Note: 24/ 7 Unescorted keyless access is to be r provided for ALL UTILITY EQUIPMENT L PV 4.0 MODULES ON ROOF DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Prior to the commencement of work, the contractor shall verify the existing roof and framing Solar Module Blocking 2x4 Modules: Module Weight(Ibs) 48.5 conditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction.Attachment Truss 2 x 4 @ 24"O.C. 35 #Of Modules 35Prior to the commencement of work, the contractor shall inspect framing for any damage Max Distributed Load: 3 PSF Total Module Weight(Ibs) 1697.5 such as water damage, cracked framing, etc. and These Plans are stamped for structural Plywood &Building Felt Rack Weight(Ibs) 339.5 code compliance of the roof framing supporting the proposed PV installation reference only. Microlnverters Weight(Ibs) 83.3 These plans are not stamped for water leakage. PV modules, racking, and attachment 1 Layer of COMP SHINGLE Total System Weight(Ibs) 2120.3 components must follow manufacturer guidelines and requirements. Attachments to be #Of Standoffs 74 installed in a staggered orientation to properly distribute loads. Max Span Between Standoffs (in) 48 Xcel EnergyApplication#05125633 Loading Per Standoff(Ibs) 28.65 pp Total Area (sq.ft.) 770 Note: 24/7 Unescorted keyless access is to be Loading (PSF) 2.75 provided for ALL UTILITY EQUIPMENT CiNGI NCC�I NC I HEREBY CERTIFY THAT THIS PLAN, i i SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION Engineerinc.io, AND THAT I AM A DULY LICENSED 303 N Glenoaks Blvd PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STAT NESOTA. Burbank, CA 91502 (747) 333 - 5991 SIGNATURE: new(cDengineerinc.io ® ATTACHMENT NAME: MANOUCHEHR HAKHA ANESHI DATE:_ _ICENSE NUMBER: 58681 RAIL — — — — — — — — — — — — — — — — Truss 2 x 4 @ 24" O.C. Date Certified and Signed: SNAPNRACK,ULTRA RAIL SPEEDSEALT"--'FOOT I CONTRACTOR IIIIIIIIII _ II III IIIIII I _ _ _ PARTS LIST I 1 b I I I I 1 0 - 1.86" 1.08'-1.3((77"QQ" ITEM QTI DESCRIPTION 1 1 O' '0.`38" 1 1 SNAPNRACK,SPEEDSEAL FOOT,BASE,SEALING,SILVER/BLACK I -- - WOLF R 1 V E R 2 1 BOLT,FLANGE,SERRATED,5/16IN-18 X 2IN,SS uzimc �Q — �ELECTRIC 3 1 SNAPNRACK,RL UNIVERSAL,MOUNT SPRING,SS _ 0 3. 5" 8" 4 1 SNAPNRACK,ULTRA RAIL MOUNT PRC,CLEAR/BLACK O II Xcel Energy Application#05125633 1 78" 5 1 SNAPNRACK,ULTRA RAIL MOUNTTAPPED PRC,CLEAR/BLACK — — — — — — — — 0.25" MATERIALS: DIE CAST A380 ALUMINUM,6000 SERIES ALUMINUM,STAINESS STEEL — I DESIGN LOAD(LBS): 802 UP,1333 DOWN,357 SIDE OPTIONS: 17" 2.24" — 3.2D" ULTIMATE LOAD(LBS): 2118 UP,4006 DOWN,1331 SIDE CLEAR/BLACK D. 2.58" ® - — Wolf River Electirc TORQUE SPECIFICATION: 12 LB-FT CERTIFICATION: UL 2703,FILE E359313;WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 \ _ _ O — — I Address:101 Isanti Parkway \ — O i NE, Isanti, MN 55040 R 1.12.33" WEIGHT(LBS): 0.45 Phone number: (763)229-6662 R1.12" - - — - - 1. 1" R 0.82" — o — — ®I E-mail:contact(a_wolfriverelectric.com 5 Q. II 1 91, o ❑ I I III ATTACHMENT 3 I I _ _ Ir �I LAYOUT -1.50"- a Cl 1 1 9 1 1 1 I 2 1 — — — — — — — — Drawn by:New@engineerinc.io 13' DATE:0611312022 151-911 Project Name Larry G Noble Property Adress: 7381 Jackson St NE Fridley, MN 55432 Project: Scale: PV SYSTEM AS INDICATED I PV 5. 1 SNAPNRACK UR SPEEDSEAL FOOT FOR MODULE HEIGHT OFF ROOF,RANGE: COMPOSTION ROOF MOUNTING UR-40:3%"-�,4. COMP SHINGLE ROOFING,TYP. REFER TO SNAPNRACK ENGINEERING CHARTS UR-60:4"-5" SNAPNRACK UR SPEEDSEAL FOOT FOR APPLICABLE RAIL SPANS. ROOF DECKING,TYP. 5/6"G3 S.S. LAG SCREW MUST EMBED A MIN. SNAPNRACK, SNAPNRACK,�/16"O S.S. OF 21A" INTO STRUCTURAL MEMBER ULTRA RAIL LAG SCREW,TYP. STRUCUTRAL MEMBER, REFER TO SNAPNRACK INSTALLATION WOOD RAFTER,TYP. MANUAL FOR Ye'0 HARDWARE TORQUE SPECIFICATIONS STRUCTURAL MEMBER SPECIFICATIONS: MINIMUM WOOD GRADE= SPF#2 MINIMUM SPECIFIC GRAVITY= 0.42 ALLOWABLE FASTENER UPLIFT =820 LBS CONTRACTOR ALLOWABLE FASTENER LATERAL= 2S0 LBS MINIMUM FASTENER EDGE DISTANCE= 0.5" MINIMUM FASTENER END DISTANCE= 2.2" WOL�RIVER 21!" MIN.EMBEDMENT INTO WOOD MEMBER ELECTRIC Xcel Energy Application#05125633 SNAPNRACK,ULTRA. RAIL MOUNT, TAPPED Vir,"WASHER,S.S. (MAY INCLUDE NEOPRENE TYPE GASKET) Wolf River Electirc PENETRATION DETAIL Address:101 Isanti Parkway NE, Isanti, MN 55040 Phone number: (763)229-6662 E-mail: ;ontact(awolfriverelectric.com SNAPNRACK, ULTRA COIL SPRING FOR 3 "0 BOLT, S.S. RAIL MOUNT,THRU �� OPTIONAL CAVITY IN UR SPEEDSEAL FOOT IS FILLED WITH SEALANT TO ENCAPSULATE AND PROTECT THE ROOF PENETRATION ATTACHMENT s/1s"0-18 X 2"BOLT, FROM MOISTURE DETAIL C SERRATED FLANGE,S.S. SNAPNRACK, SPEEDSEAL FOOT, BASE,SEALING ENGI NEEr-:Z INC EXPLODED Drawn by.New@engineerinc.io �Il+z��� DATE:0611312022 SEALANT Project Name: Larry G Noble Properly Adr- 2%" 7381 Jackson St NE 1 ROOF DECKING; Fridley, MN 55432 L] Project: Scale: PvSYSTEM L AS INDICATED UR-40 RAIL I UR-60 RAIL STRUCTURAL MEMBER(RAFTER)FOR USE WITH SNAPNRACK ULTRA SERIES RAILS - — FPV 5.2 '=k ENPHASE amom IQ8 and IQ8+ Microinverters I 1 1•. Commonly used module pairings' w 235-350 235-440 Module compatibility 60-celIA20 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currentz[module[so] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array:No additional DC side protection required:AC side protection requires max 20A per branch circuit OUTPUT 1 ,1 Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(Ivoltage/range3 V 240/211-264 CONTRACTOR Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 IQ8 and IQ8+ Microinverters Extended frequency range Hz 50-68 Max units per 20 A(I branch circuit' 16 13 WO L�R 1 V E R Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Total harmonic distortion <5% ELECTRIC defined microinverters with split-phase power conversion capability to convert DC Overvoltage class AC port III power to AC power efficiently.The brain of the semiconductor-based microinverter Easyto install is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with AC port backfeed current ma 3o Xcel Energy Application#05125633 microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting 1.0 55nm technology with high speed digital logic and has super-fast response times Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-0.85lagging to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Peak efficiency % 97.5 97.6 energy systems. • Faster installation with simple CEC weighted efficiency °6 97 97 Wolf River EleCtiCC two-wire cabling Night-time power consumption mw 60 Address:101 Isanti Parkway Enphase MECHANICAL DATA NE, Isanti, MN 55040 -. Phone number: (763)229-6662 High productivity and rellal71117y Ambient temperature range -40°C to•600C(-40°F to+740°F) E-mail:contact(a�wolfriverelectric.com • Produce polder even when the Relative humidity range 4%to 100%(condensing) grid is down 1- L DC Connector type MC4 More than one million cumulative Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Part of the Enphase Energy System,IQ8 Series IQ8 Series Microinverters redefinereliability hours Of testing Microinverters integrate with the Enphase IQ standards with more than one million Weight 1.08kg(2.38lbs) INVERTER Battery.En phase IQ Gateway,and the Enphase cumulative hours of power-on testing. • Class lldouble-insulated Appmonitoring and analysis software. enabling an industry-leading limited warranty enclosure Cooling Natural convection-nofans DATA SHEET of up to 25 years. Approved for wet locations Yes • Optimized for the latest high- powered PV modules Acoustic noise at 1m -60 dBA Pollution degree PD3 ep::r CERTIFIED Microgrid-forming Enclosure Class II double-insulated.corrosion resistant polymeric enclosure ENG 1 NEEv-:2 1 NC Complies with the latest Environ.category/UV exposure rating NEMA Type 6/outdoor advanced grid support moil Drawn by.New@engineerinc.io Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as DATE:0611312022 q Y ry Remote automatic updates for CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 N0.107.1-01 IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform project Name: Q-DCC-2 adapter cable with lu n- la MC4 with various regulations, installed the latest grid requirements P P 9- P Y e9 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conformswith NEC 2014.NEC 2017.and NEC 2020 section Larry G Noble connectors. according to manufacturer's instructions. Configurable to support a wide 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors.when installed accordingto range of grid profiles manufacturers instructions. Property Adress: 7381 Jackson St NE ®2021 Enphase Energy.All rights reserved.Enphasa the Enphase logo.IQ8 microinverters. Meets CA Rule 21(LIL 1741-SA) (1)No enforced DC/AC ratio.Seethe compatibility calculator at httpsJ/Iink.enphase.com/ Fridley, MIN 55432 and other names are trademarks of Enphase Energy.Inc.Data subject to change requirements module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage — range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to Project: scale: IQ8SP-DS-0002-01-EN-11S-2021-10-19 local requirements to define the number of microinverters per branch in your area. I08SP-DS-0002-01-EN-US-2021-10-19 PV SYSTEM L AS INDICATED D 6.0 • � ENPHASE Install the Enphase IQ8 Series Microinverter To install Enphase IQ8 Series Microinverters,read and follow all warnings and instructions in this guide and in the Enphase IQ8 Series Microinverter Enphase Energy//Rapid Shutdown Installation and Operation Manual at aelnhase-com/stnprt Safety warnings are listed on the back page of this guide. The Enphase Microinverter models listed in this guide do not require grounding electrode conductors(GEC),equipment grounding conductors(EGC),or grounded conductor(neutral).The microinverter has a Class II double-insulated rating,which includes ground fault protection(GFP).To support GFP,use only PV modules equipped with DC cables labeled PV Wire or PV Cable Rapid shutdown is built-in IMPORTANT:Enphase IQ8 Series Microinverters require the IQ Cable.An IQ Gateway is required to monitor performance of the IQ Microinverters.The Q Accessories work only with Enphase IQ8 Series Microinverters. Note:After you log in to your Enphase Installer Platform account from Enphase Installer app,Scan the microinverter QR code and connect to the Enphase IQ Gateway to track the system installation progress. The 2014 edition of the National Electrical Code(NEC 2014)added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. NEC 2014,Section 690.12 applies PREPARATION Enphase Microinverters full meet rapid shutdown requirements in the to PV conductors over 10 feetfrom p y p q A Download the pp and o te Enphase Installer A n it to to ) s: the PV array and requires that the ) p � g D Check that you have these other item e ��.� e new code without the need to install any additional electrical equipment. in to your Enphase Installer Platform account.With this r+,,� ACjunction box. conductors power down to 30 volts t.. �} app,scan the microinverter QR code and connect to x Tools:screwdrivers,wire cutter,voltmeter,torque wrench,sockets, and 240 volt-amperes within the Enphase IQ Gateway to track system installation r�' and wrenches for mounting hardware seconds of rapid shutdown inittiation. progress.To download,go to enphase.com/toolkit or scan the QR code at right. E) Protect your system with lightning and/or surge suppression devices.It is also important to have insurance that protects against lightning and String inverters require work arounds for rapid shutdown B) Referto the foseco /table en-uandcheckPVmle-cQmlectricalcompati electrical surges. bility at:Qpphase.com/en-uc_/suonort/modulezom com/en-us/sur)pr)rt/module-cQmpalbAily. Model DC connector Typical PV module*cell count IF Plan your AC branch circuits to meet the following limits for maximum CONTRACTOR &60 2-US MC 4lockin number of microinverters per branch when protected with a 20-amp Work around. Work around. I Q g type Pair with 60 cell/120-half-cell over-current protection device(OCPD) Specialized Rapid Shutdown String Inverter Installed modules electrical box installed on the on roof,a hostile IQBPLUS-72-2-US MC-4 locking type Pair with 60 cell/120-half-cell,66 Maximum* IQ8 Series Microinverters per AC branch circuit(sin- roof cell,or 72 cell/144-hhalf--cell le- hase roof within 10 feet of array. environment that string g P ' WOLR 1 V E R IQ8A-72-2-US IQ8(240V IQ8+ 240V IQ8M(240V) o live irs are not built ) ( ) IQ8F+240-72-2-US MC-0 locking type Pair with 60 cell/120-half-cell,66 Work around. to live in. IQ8H-208-72-2-US cell,or72 cell/144-half--cell 16 13 11 ELECTRIC Shutoff switch that Is `Enphase IQ8 Series Micrdnverters are compatible with bi-facial PV modules if IQ8A(240V) IQ8H(240V) IQ8H(208V) the temperature adjusted electrical parameters(maximum power,voltage and 11 10 9 easily accessible to first current ofthe modules,consideri the front side electrical parameters(i.e., o Xcel Energy Application#05125633 rt9 P ( Limits may vary.Refer local requirements to defne the number of responders on the ground. backside gain),are within the allowable microirrverter input parameters range. microinverters per branch in your area. w it C) In addition to the Enphase Microinverters,PV modules and racking, G) Size the AC wire gauge to account for voltage rise.Select the correct you will need these Enphase IQ8 Series Microinverters: wire size based on the distance from the beginning ofthe Enphase IQ Work around. Enphase IQ Gateway(model ENV-IQ-AM 1-240)communications Cable to the breaker in the load center.Design for a voltage rise total Extra conduit in Installation. Residential String Inverter Commercial String Inverter gateway or Enphase IQ Combiner(check enphase.com for models): of less than 2%for these sections.Refer to the Voltage Rise Technical Wolf River Electirc is required to monitor solar production. Brief at ennhase_com/support for more information. Address:101 Isanti Parkway Tie wraps or cable clips(Q-CU P-100) NE, Isanti, MN 55040 Enphase Sealing Caps(Q-SEAL-10):for any unused connectors on Best practice:Center-feed the branch circuit to minimize voltage rise in Phone number: (763)229-6662 the Enphase IQ Cable a fully-populated branch. Enphase Terminator(Q-TERM-10):one needed at the end of each E-mail:contactt_wolfriyerelectric.com Enphase comes standard with rapid shutdown capability AC cable segment Enphase Disconnect Tool(Q-DISC-10) Enphase IQ Cable: ENPHASE RAPID Cable model Connector PV module Connectors SHUTDOWN All Enphase microln- Enphase microinverters spacing* orientation per box r verters,even those that can safely shut down Q-12-10-240 1.3m Portrait(al 1) 240 Terminator COMPATIBILITY were previously installed, automatjcally,leaving Q-12-17-240 2.0m Landscape(60-and 66-cell) 240 WITH PV inherently meet rapid only low-voltage DC Q-12-20-200 2.3m Landscape(72-ce1I) 200 shutdown requirements, electricity isolated to *Allows for 30cm of cable slack no additional equipment the PV module E CNGINCCIZINC or workarounds needed Enphase IQ Cable Drawn by.New@engineerinc.io AC connector DATE:0611312022 DC connector 02021 Enphase Energy All rights reserved. Enphase,the Enphase logo,Enphase IQ8 P otect Name: Residential Microinverter Commercial Microinverter R Series micranverters(IQ8,IQ8+,IQ8A,IQ8H Larry G Noble `Tie wraps or cable clips and IQ8M),Enphase Installer Platform, Property Adress: Enphase IQ Gateway,and other trademarks 7381 Jackson St NE or service names are the trademarks of Fridley, MN 55432 Enphase En Inc.Data subecttochan a y, �—Enphase IQ8 Series Microinverter P Energy, 1 9 r1l enphase� (horizontal installation shown,vertical Rev02-10-23-2021. Project: scale: To learn more,visit enphase.com C�J E N E R G Y installation also allowed). III IIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIII III PV SYSTEM AS INDICATED AC junction box 14"0195-02 D 7.0 MECHANICAL SPECIFICATION f pVQ © Format 74.01nx41.1in x 1.261n(including frame) (1879mm x 1045mm x 32mm) @rproem°I Weight 48.51bs(22.0kg) Front Cover 0131n(32mm)thermally pre-stressed glass withI� ` anti-reflection technology L � °.6°ua.q�.a.ora 1°2mml Back Cover Composltefilm aa.,wamml Frame Black anodized aluminum r ell 6 x 22 moriDaystalline GANTUM solar half cells ® arumem� Junction Box 2.09-3.98Inx1.26-2.361n-0.59-0.71in (53 101 mm x 32-60 mm x 15-18 mm),IP67,with bypass diodes Cable 4mm2 Solar cable;(+)>_49.2in(1250mm),I-)z49.2in(1250mm) .• t ..mry ue Connector StaubliMC4;IP68 ILI I • ovr-poem T Q . • : , ELECTRICAL CHARACTERISTICS POWERCLASS 385 390 395 400 405 MINIMU M PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Power at MPP' P_ [wj 385 390 395 400 405 ShortCUcult Current' Isc [A] 11.04 U.07 U10 11.14 11.17 � E Open Circuit Voltages V.. M45.19 4523 45.27 45.30 45.34 •• • E I �Q S Current at MPP I,- [A] 10.59 10.65 10.71 10.77 10.83 Tore�xo� ' Voltage at MPP V_ M 36.36 36.62 36.88 1 3713 3739 CONTRACTOR ' Efficlency' 4 [%] >_19.6 z19.9 a20-1 z20.4 z20.6 euaart ZO21 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT� Warranty Q CELLS Power at MPP P_ PM 288.8 292.6 296.3 30D.1 303.8 rm�a ate.a.r Yielder,try E Short Clreuii Cumera Ix [A] 8.90 8.92 8.95 8.97 9.00 .9 Open Circuit MPP I_ [A] 42.62 42.65 42.46 48.51 42.76 WOL�RIVER BREAKING TH E 20%EFFICIENCY BARRIER � Current at MPP L,F, [Aj 8.35 8.41 8.46 8.51 8.57 Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at MPP V_ M 34.59 34.81 35.03 35.25 35A6 ELECTRIC boosts module efficiency up to 20.9%. 'Measurement Werances Pmv t3%;1,6 V_t5%atSTC:1000W1m=,25t2'C,AM 1.5 according to IEC 60904-3•1800W/m',NMOT,spectrum AM 15 0 CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE Xcel Energy Application#05125633 THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY ,�m a- --T-----r-----r-----I---- u_ Atleast 98%of nomnalpow rduring Q CELLS is the first solar module manufacturer to ass the most com rehen- S= -" P P _w First year-Thereafter max-0.5% sive quality programme in the industry:The new"Quality Controlled PV"of g •• ----------------- degradation per year.At least 93.5% 5Iii of nominal power up to 10 years.At I the independent certification institute TOV Rheinland. F least 86%ofnominal power up to 25years. c p __r_____r____y_____.y_____ < s Wolf River Electirc INNOVATIVE ALL-WEATHER TECHNOLOGY ° Al data wthln measurement tolerant- o a 6 es.Full warranties In accordance with Address:101 Isanti Parkway Optimal yields,whatever the weather with excellent ae .eo se 2 the warranty terms of the C,CELLS .00 ,om IaaaouacE Iwr�,I NE, Isanti, MN 55040 low-light and temperature behavior. sales agenisauonot you respective � $ ` m country. R Phone number: (763)229-6662 sues Typical module performance under lox irradlance conditions In .n ENDURING HIGH PERFORMANCE "s compadsontoSTCconwtlons(25•C,1000W/m9 E-mail: ;ontact@wolfriverelectric.com I. 1 Long-term yield security with Anti LID Technology,Anti PID TEMPERATURE COEFFICIENTS o Technology',Hot-Spot Protect and Traceable Quality Tra.Q' . Temp,, a [%/Kl +0.04 Temperature Coefficient of V.,, A [%/K] 70.27 4 s Temperature Coefficient of P° Y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109t5.4(43t3°C) EXTREME WEATHER RATING o High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN 2 MODULE high Snow(540o Pa)and Wind loads(4000Pa). Maximum System Voltage V­ M 1000(IEC)/1000(UL) PV module classification Class ll p DATA SHEET Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE2 2� A RELIABLE INVESTMENT �wrte� Inclusive 25-ear product warrant and 25- ar Max.Design Load,Pushush// Pull' [Ibs/ft'J 75(3600Pa)/55(2660Pa) Permitton Continuous Module Temperature -40°F up to-85'C) p �/•1y y p y � Max.Test Load,Push/Pulp [Itu/ft'] 113(5400 Pa)/84(4000 Pa) y (-40°C up to+85°C) linear performance warranty'. 'Sea Instalatlon Manuel `APT test sheeto reaccordingto IEC/ atlor, 4-12015.methodA(-1500V,98h) QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ENGINEE�INC 'See dale sheet on rear for further nfomf�lort //��� ° Drawn by:New@engineennc.io ULo1730.GEcomp oamtyc­aledw-T-Tfrvlananmm, � I+4�1 � DATE:O6/13/2022 IEC 612152016.IEC 61730:2016, THEIDEALSOLUTIONFOR: us.PaWl No.9.8 215r-Cars). s�° C C. a.w.'v horizontal 76.4in 43.31n 48.01n 1656lbs 24 24 32 if Project Name: oCPVC-ffi etbn-tNi q C ,US packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules .8 Larry G Noble Rooftcparrayson u ii,m resldentlalbulldlnps. `� Property Adress: Not«Installation Instructions must be followed.See the lnstalatlon and operating manual or collect our technical service deperonent for further lnformatlon on approved installation and use of 7381 Jackson St NE this product. - Fridley, MN 55432 Nu CELLS Project: Scale: R Numbs Inc. PV SYSTEM AS INDICATED Engineered)n Germany 400 Spect um Conte Drive,Surte 1400,Irvlre,G4 92618,USA TEL+1 949 748 59 96 1 EMAIL Inqulry�us.gtels.com WEB www.¢celB.us D L8.0 Snap rack- UR-40 SnapNrack Ultra Rail UR-60 A sleek, straightforward rail solution for mounting solar modules .. types. Ultra Rail Solar Mounting Solutions features two rail profiles; , • is a lightweight rail profile suitable • •st geographic Ultra Rail • - •• • rail . . . . .. . . . .. .. . ... :. compatible with all . . . . clamps, . . . of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge CONTRACTOR Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install WOL�RIVER • Industry best wire management offering ELECTRIC includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Xcel Energy Application#05125633 Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard Wolf River Electirc Address:101 Isanti Parkway NE, Isanti, MN 55040 • Phone number: (763)229-6662 Industry ' • • • Wire Mounts • • E-mail: ;ontact(a)_wolfriverelectric.com Management Heavy Duty UR-60 Rail • • • • • _ • UR-60 rail profile provides increased span capabilities for high wind speeds and snow Single loads ��� � RACKING • • • • • • • Taller, stronger rail profile includes profile- Clamps : Accessories specific rail splice and end cap DATA SHEET _ compatible • All existing mounts, module clamps, and accessories are retained for the same great both rail profiles install experience CNGINCC�INC Drawn by.New@engineerinc.io DATE:0611312022 • •- • • roject Name: - • • • Larry G Noble P Quality. Inn .ovative Superiorrr Popety Adress: RESOURCES snapnrack.com/resources � 73s1 Jackson St NE SnapNrack Solar • • Solutions engineered to optimize material _ • Fridley, MN 55432 DESIGN snapnrack.com/configurator Project Scale- labor res• and improve overall installationquality and safety. Pv SYSTEM LAS INDICATED WHERE TO BUY snapnrack.com/where-to-buy 877-732-2860 • • • • F—D 9.0 DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: SNAPNRACK, ULTRA RAIL SPEEDSEALTm FOOT mwatkins 5flapHruck" SNAPNRACK, ULTRA RAIL SPEEDSEALTm FOOT mwatkins Sfla NN ack- REVISION: Solar Mounting Solutions REVISION: Solar Mo unting Solutions PART NUMBER(S): PART NUMBER(S): 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,LA 96105 USA 595 MARKET STREET,29TH FLOOR.SAN FRANLISOO,CA 94105 USA A PHONE(415)500 0900.FAX(415)500.0902 PHONE(415)500b900•FAX(415)5MM2 242-02163, 242-02167 �ENFo.MroKNTHIsoF 9HosoKF9LN� �oaROPR1 .9. N. 242-02163, 242-02167 E .o. �=C""'mu,µo�aoaP. . �.�r 1.37 .30 .38 1.86- 1.08 1.00 v�5a SLOT 3.05 CONTRACTOR 2.78 5 mpNmck 1.78 .25 WOL�ELECTRIC RIVER L 17 _ Q52.24� -�3.20�- Xcel Energy Application#05125633 2.58 4 3 Wolf River Electirc 0.33 Address:101 Isanti Parkway R1.12 NE, Isanti, MN 55040 Phone number: (763)229-6662 1.21 R•82 E-mail:contacta_wolfriverelectric.com 2 1 ATTACHMENT DATA SHEET PARTS LIST 1.99 ITEM QTY DESCRIPTION 1 1 SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/ BLACK 2 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SS 11 ENG1NEEZINC 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 4 1 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/ BLACK Drawn by:New@engineerinc.io DATE:0611312022 5 1 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/ BLACK 1.50 MATERIALS: DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINLESS STEEL Project Name: Larry G Noble DESIGN LOAD (LBS): 802 UP, 1333 DOWN, 357 SIDE OPTIONS: Pmperty Adfe99: ULTIMATE LOAD (LBS): 2118 UP, 4006 DOWN, 1331 SIDE CLEAR/ BLACK 7381 Jackson St NE TORQUE SPECIFICATION: 12 LB-FT Fridley, MN 55432 Project: I Scale: CERTIFICATION: UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 PV SYSTEM AS INDICATED WEIGHT(LBS): 0.45 ALL DIMENSIONS IN INCHES FD 10.0 Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-IQ-AM1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-IQ-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenuegradePV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5 0).Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05),a plug-and-play industrial-g rade cell modem for systems up to 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in En hase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat p IQ Gateway and integrated LTE M1 cell ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Q Combiner 4/4 C Ensemble Communications Kit -Includes COMMS-KIT-Ol and CELLMODEM-Ml-06-SP-05 with 5-year Sprint data plan for modem(included only with IQ Combiner 4C) COMMS-CELLMODEM-Ml-06 Ensemble sites CELL MODEM-M1-06-SP-05 -4G based LTE-Ml cellular modem with 5-year Sprint data plan X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-Ml-06-AT-05 4G based LTE-Ml cellular modem with 5-year AT&T data plan X-I AM 1-240-4 C Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers Q- into a single enclosure and streamlines IQ BRK-10A-2-240V Circuit breaker,2 pole,IOA,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,l5A,Eaton BR215 microinverters and storage installations by BRK-20A-2P-24oV Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-24oV-B Circuit breaker,2 pole,l5A.Eaton BR215B with hold down kit support providing a consistent, pre-wired solution for BRK-2DA-2P-24oV-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support a— residential applications. It offers up to four EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) "'" busbar assembly.y XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws ELECTRICAL SPECIFICATIONS Smart Rating Continuous duty CONTRACTOR Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Hz Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125A (CELLMODEM-Ml-06-SP-05),Included only With IQ Max.continuous current rating 65A Combiner4C Max.continuous current rating(input from PV/storage) 64A WOL�RIVER Includes solar shield to match Enphase IQ Battery Max fuse/circuit rating(output) 90 A ELECTRIC aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Flexible networking supports Wi-Fi, Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included Ethernet,or cellular Xcel Energy Application#05125633 Envoy breaker 10A or 15A rating GE/Siemens/Eaton Included Optional AC receptacle available for PLC bridge Production metering CT 200 A solidcore pre-installed and wired to IQ Gateway Provides production metering and consumption monitoring Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers MECHANICAL DATA Dimensions(WxHxD) 37.5 x 49.5 x 16.8 cm(14.75"x 19.5'x 6.63").Height is 21.06"(53.5 cm)with mounting brackets. AddrWolf Rivss:1 0 EIsanti Simple Address:101 Isanti Parkway Weight 7.5kg(16.5lbs) NE, Isanti, MN 55040 Centered mounting brackets support single Ambient temperature range AOO C to+460 C 000 to 1150 F) Phone number: (763)229-6662 stud mounting Cooling Natural convection,plus heat shield E-mail: :ontact@wolfriverelectric.com Supports bottom,back and side conduit entry Up to four 2-pole branch circuits for 240 VAC Enclosure environmental rating Outdoor,NRTLcertified,NEMA type 3R polycarbonate construction • plug-in breakers(not included) Wire sizes 20 A to 50 A breaker inputs.14 to 4 AWG copper conductors • 60 A breaker branch input:4 to 1/0 AWG copper conductors X-IQ-AM1-240-4C 80A total PV or storage branch circuits Main lug combined output 10 to 2/O AWG copper conductors ENPHASE Neutral and ground.14 to 1/0 copper conductors Always follow local code requirements for conductor sizing AC COMBINER BOX Reliable Altitude To 2000 meters(6,560feet) • Durable NRTL-certified NEMA type 3R enclosure INTERNET CONNECTION OPTIONS DATASHEET Five-year limited warranty Integrated Wi-Fi 802.1lb/g/n Two years labor reimbursement program coverage Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-Ml cellular modem).Note that an Enphase included for both the IQ Combiner SKU's Mobile Connect cellular modem is required for all Ensemble installations UL listed Ethernet Optional,802.3.Cat5E(or Cat 6)UTP Ethernet cable(not included) ENG I NEED 1 NC COMPLIANCE Drawn by.New@engineerinc.io compliance,IQ Combiner UL 1741.CAN/CSA C22.2 No.1071,47 CFR,Part 15,Class B,ICES 003 DATE:0611312022 O Production metering:ANSI C12.20 accuracy class 0.5(PV production) ULConsumption metering:accuracy class 2.5 project Name: Compliance,IQ UL60601-1/CANCSA22.2No.61010-1 LarryG Noble X-IQ-AMt-240-4 LISTED ENPHASE ENPHASE Prope y Actress: To team more about Enphase offerings,visit enphase.com \./ To learn more about Enphase offerings,visit enohase.com \/ 7381 Jackson St NE Q 2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Fridley, MN 55432 Enphase Energy,Inc-Data subject to change.02-14-2022 Project: I Scale: PV SYSTEM AS INDICATED D L _i 1 .0 CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE Certificate Number 20180530-E341165 Certificate Number 20180530-E341165 Report Reference E341165-20171030 Report Reference E341165-20171030 Issue Date 2018-MAY-30 Issue Date 2018-MAY-30 Issued to: ENPHASE ENERGY INC This is to certify that representative samples of the product as specified on this certificate were tested 1420 N McDowell Blvd according to the current UL requirements. Petaluma CA 94954-6515 Permanently-connected, Grid Support utility Interactive,208V single-phase,240V single phase evaluated for use on a split phase system, distributed resource power system. This is to certify that STATIC INVERTERS, CONVERTERS AND representative samples of ACCESSORIES FOR USE IN INDEPENDENT POWER Models 2-2-U,land IQ7 -72, and IQ7X 96,followed by 2,-5, B,or ACM,followed by US+. Models IQ7PD-72-2-US and IQ7PD-842-US. SYSTEMS, PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT USUCNL—Photovoltaic Rapid Shutdown Equipment. See Addendum Models IQ7-60,IQ7PLUS-72, and IQ7X-96,followed by-2,-5,-B,or-ACM,followed by-US+. Models CONTRACTOR IQ7PD-72-2-US and IQ7PD-84-2-US. Have been investigated by UL in accordance with the +may be followed by additional characters not affecting safety Standard(s) indicated on this Certificate. WOL�RIVER Standard(s)for Safety: ELECTRIC Standard(s)for Safety: See Addendum UL 62109-1,SAFETY OF POWER CONVERTERS FOR USE IN PHOTOVOLTAIC POWER Xcel Energy Application#05125633 Additional Information: See the UL Online Certifications Directory at SYSTEMS-PART 1: GENERAL REQUIREMENTS www.u1.com/database for additional information CSA C22.2 NO. 107.1-01, GENERAL USE POWER SUPPLIES IEEE 1547 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Wolf River Electirc Only those products bearing the UL Certification Mark should be considered as being covered by UL's Address:101 Isanti Parkway Certification and Follow-Up Service. IEEE 1547.1 IEEE STANDARD CONFORMANCE TEST PROCEDURES FOR EQUIPMENT NE, Isanti, MN 55040 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Phone number: (763)229-6662 Look for the UL Certification Mark on the product. E-mail: .:ontact(a�wolfriverelectric.com UL 1741. INVERTERS,CONVERTERS,CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY RESOURCES CEC-300-2011-005,-CMF GUIDELINES FOR CALIFORNIA'S SOLAR ELECTRIC INCENTIVE PROGRAMS PURSUANT TO SENATE BILL 1 INVERTER CERTIFICATION ENGINEEw-;ZINC Drawn by.New@engineerinc.io DATE:0611312022 Project Name: &uo.MMr A,dt 0.. N—h All—C.lU61-1 Plogmn &uc.MaM.rJldc Ur.ctm N.nll Anroncan C-1fl ua1 Ploymn Larry G Noble UL LLC ` UL LLC L Property Adress: AnylMorm wenddocvm.mdlwnvdmgULMlMs.rvk.sereprowd.donU1.foIUL LLC(UL)mm1Ya11m�z.d1—m..WULForµnsborls.Flax AirylMmmuimmiddoam.ndi--dwngULMaks.rwc —prowdedonb.hWlWUL LLC IULIamW--..dYtense.MULForqu.stb plan. 7381 Jackson St NE ..Mml a lord UL Cu­Smw R.pr.smtmly.at I JW l:d bcW UL CUWonwr S.—R.W.sm.l.m 11R­uLc dr.ulutloc.— Fridley, MN 55432 Page 1 of 2 Page 2 of 2 Project: scale: PV SYSTEM AS INDICATED Created by UL Document Assembler 2018-07-05 15:07:07-05.00 Created by UL Document Assembler 2018-07-05 15:07:07-05.00 D 12.0 I 101 f I I I N a♦ " Surge Protection RT NUMRER MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Nominal Voltage 0 to 90 VAC 0 to 250 VAC 0 to 300 VDC 0 to 480 VAC 0 to 115 VDC 0 to 600 VDC - MCOV 180V 470V 470V 780V Surge Protection You Can VPRLinetoGround 600V 1200V 1200V 1800V ' Suggested Placement Up to 90VAC circuits, 120/240 VAC circuits Off-grid PV combiners 316V/480VAC circuits Count 4n• 12V,24V,48VDC battery Charge controller inputs Grid-tie PV combiners f circuits up to 30OVDC Grid-tie inverter input Non-Isolated Inverters MidNite Solar Surge Protection Devices are type 1 devices, designed for indoor and outdoorType UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 g .4 _ rr - A'.a' applications. Engineered for both AC and PV +� Diagnostic Blue LED MNSPD 300 AC DC electrical systems, the rOVld@ protection LED indicates when voltage is present between Ll +ground and L2+ground Y Y P P MNSPD-115,MNSPD-300-DC and MNSPD-600: to service panels, load centers or electronic LED indicates when voltage is present between Ll +L2(PV+PV-) devices that are directly connected to a MidNite Thermal Disconnector Internal Fuse Surge Protection Device (SPD). Response Time <1 micro sec. I n CONTRACTOR MidNite's SPDs are offered in four models to protect a variety of different voltage ranges. They achieve this protection by clamping surge MNSPD300ACFM (Cut-in box) WOL�RIVER voltage to a level that your system can sustain (MNSPD-300-AC included) ELECTRIC without damaging the components of the Performance system. Surge Current Rating per Phase 80kA Xcel Energy Application#05125633 03.527" Short Circuit Current Rating 10kA Compare our SPDs against other surge protec- Fusing Individually fused MOVs tion devices. You will see there is no com an- Thermal Fusing Yes P + Over current Fusing Yes Wolf River Electirc son in both our price and features. All our SPDs Operating Frequency 0 to 500 Hz Address:101 Isanti Parkway are made in the USA and have a 5 year warranty. Mechanical Description NE, Isanti, MN 55040 Enclosure Polycarbonate UL94V-0 Phone number: (763)229-6662 Environmental Rating Type4X E-mail: ;ontact(awolfriverelectric.com Connection Method #12 AWG With lightning you only get one Weight 1 lb. Mounting Method 1/2"Conduit Knockout Operating Altitude Sea Level- 12,000'(3,658 Meters) chance, so get the best! 3 82„ 4.425" Storage Temp -401 Fto+185 F(-40°Cto+85°Q SURGE PROTECTION Operating Temp -40,F to+185,F(-40°C to+85,C) Diagnostics Blue status LED,one per leg Four Models: Listings and Performance 24"Wires.AtI MNSPD-115 UL Standard for Safety,UL 1449 Surge Protective Devices-Fourth Edition ENGINEE�INC CSA C22.2 No.8-M1986 Electromangetic Interference(EMI)Filters,Fourth Edition Drawn by.New@engineerinc.io MNSPD-300-AC DATE:0611312022 MNSPD-300-DC Project Name MNSPD-600 Model No. Max Operating Surge Current Configuration MCOV SCCR VPR 60OV/3kA Larry G Noble r i Voltage per Phase L_G PropertyAdr— MNSPD-115 100 VAC/1 50VDC 80kA Ig 3-wire 2Legs) , 180VL-N i 10kA 600V 7381 Jackson St NE MNSPD-300-AC 300VAC 80kA 1 3-wire(2 Legs) 470V L-N 10kA 1200V M rk_ffij� _l _ I Fridley, MN 55432 NSPD-300-DC r 385VDC � 80kAe(2 Legs) t 470V L-N � 10kA 1200VMNSPD-600 480VAC/60OVDC 80kA 1/3-wire(2 Le s) 780V L-N 1 OkA 1800V Projectscalewww.micinitesolar.comispd I PV SYSTEM L AS INDICATED 17722 67th Ave.NE.,Arlington,WA.360-403-7207 FAX:360-691-6862 www.midnitesolar.com/spd 17722-67th Ave NE.Arlington,WA 98223 PH. 360-403-7207 FAX 360-691-6862 D 13.0 WITNESS TEST PROCEDURE Larry Noble A TEST PROCEDURE THAT WILL BE USED TO VERIFY THE PROTECTION AND OPERATION OF THE SYSTEM SHALL BE SUBMITTED TO XCEL ENERGY FOR APPROVAL.THE PROCEDURE INCLUDES AN ANTI-ISLAN DI NG TEST(FOR ALL SYSTEMS)TO VERIFY THE SYSTEM CEASES GENERATING IN PARALLEL WITH THE XCEL EN ERGY 7381 Jackson St N E DISTRIBUTION SYSTEM WHEN THE UTILITY SOURCE IS LOST. EACH SYSTEM IS UNIQUE AND WILL REQUIRE A CUSTOM TEST PROCEDURE BASED ON THE INVERTER Fridley, MN 55432 MANUFACTURER'S RECOMENDATIONS FOR COMISSIONIND AND ANTI-ISLANDING. IN ADDITION TOTHE MANUFACTURER'S RECOMENDATIONS. UTILITY:XCEL ENERGY ALLTESTING SHALL BE PERFORMED BY QUALIFIED PERSONELLONLY PHOTOVOLTAIC PROJECT INFO PV MODULE:(35) HANWHA 40OW STEPS TO VERIFY PV SYSTEM IS READYTO BE ENERGIZED: INVERTER: 1.SITE SECURITY I-PHASE 120/240 -SITE SHOULD HAVE 24/7 KEYLESS ENTRY AND DRIVABLE ACCESS IF XCEL EQUIPMENT IS PRESENT WITHIN THE SITE FENCE (35) IQ8+MICROINVERTERS -IF APPLICABLE,SITE SHOULD HAVE 24/7 DRIVABLE ACCESS TO ANYXCEL EQUIPMENT INSTALLED OUTSIDE OF THE SITE FENCE THAT IS USED FORTHE SOLE 14.00Kw(DC) PURPOSE OF FEEDING THE PV SYSTEM ARRAYI AZI MUT:90(19) ARRAY2 AZI MUT: 180(6) 2. PROPER LABELLING ARRAY3 AZI MUT: 180(7) VERIFY LABELING FORTHE MAIN SERVICE PANEL, PV SYSTEM CIRCUIT BREAKER, DC DISCONNECT(WHEN APPLICABLE),UTILITYAC DISCONNECT, PRODUCTION METER AND OTHER RELEVANT LABELLING AND SIGNAGE. ARRAY4 AZI MUT:270(3) ARRAY TILT:20 3. ENERGIZETHE PV SYSTEM BYCLOSINGTHE UTILITY DISCONNECT.PLEASEALLOW 5-MINUTE FORTHE INVERTERTO BOOT-UP. NEC 2020/IRC 2018/IBC 2018 WOLF RIVER ELECTRIC COMPANY 4.WHILE IN NORMAL OPERATION, REFER TO THE REFERENCE POI NTOF APPLICABI LITY TO VERIFY THE VOLTAGES ATTHE INVERTER AC OUTPUT ARE WITHIN 5%OF THE COMBINED INVERTED AC VOLTAGE RATINGS AND ALL INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE"NORMAL." 101 ISANTI PARKWAY NE#G ISANTI, MN 55040 CONTRACTOR 5.WHILE IN NORMAL OPERATION,VERIFY THAT ALL INVERTERS ARE OPERATIONAL AND PRODUCING POWER.VERI FY THAT SYSTEM ISGENERATING AT FULLEST CONTACT@WOLFRIVERELECTRIC.COM REASONABLE CAPACITY.WHI LE I N NORMAL OPERATION VERI FY THE VOLTAGES ATTHE DER AC TERMI NALS ARE WITHIN 5%OF THE COMBI N ED DER AC VOLTAGE WOLF RIVERELECTRIC.COM RATINGS AND ALL LEDs,ALARMS AND/OR LCD CODES ARE"NORMAL" WOL�RIVER 6.SI MULATE THE LOSS OF UTI LITY SOURCE FOR THE ANTI-ISLAN DI NG TEST BY OPEN I NG THE"UTI LI LITY AC DISCON N ECT". ELECTRIC Larry G Noble Xcel Energy Application lication#05125633 7.USING A VOLTMETER,VERIFYTHE VOLTAGE ATTHE INVERTER SIDE OF THE AC DISCONNECT HAS DROPPED TO ZERO WOLF RIVER SOLAR CASE#05125633 NOTE:ONLY CUSTOMER-OWNED EQUIPMENT SHALL BE USED FOR THIS VERIFICATION. 24/7 UN ESCORTED ACCESS SHALL BE Wolf River Electirc 8.USING AN AMMETER OR THE INVERTER'S DISPLAY,VERIFY THE DER OUTPUT OF THE INVERTER HAS CEASED WITHIN TWO SECONDS. PROVIDED FOR THE METERS&AC Address:101 Isanti Parkway DISCONNECT NE, Isanti, MN 55040 Phone number: (763)229-6662 9.VERIFY I NVERTER LED'S,ALARMS,AND/OR LCD CODES ARE APPROPRIATE FOR LOSS OF UTILITY SOURCE E-mail:contact(a_wolfriverelectric.com METERS&UTILITY DISCONNECT WITHIN 10.RESTORE THE LOST UTILITY SOURCE BY CLOSING THE"UTILITYAC DISCONNECT 10'&LINE OF SIGHT 11.VERIFYTHATTHE INVERTER SYSTEM DELAYS 5 MINUTES BEFORE RESUMING POWER OUTPUTAFTER THE UTILITY SOURCE IS RESTORED UTILITYAC DISCONNECT IS VISIBLE WITNESS TEST LOCKABLE&READILY ACCESSIBLE PROCEDURE 12.VERIFY FIXED POWER FACTOR SETTINGS FOR EACH INVERTER MEETTHE PROJECT REQUIREMENTS GROUND SNOW:50PSF 13.METER TECH HAS VERIFIED METERING EQUIPMENT WIND SPEED: 115MPH ENGI NEE r-:zINC EXPOSURE CATEGORY: B 14.SYSTEM RESUMED DELIVERY OF POWER NO LESS THAN 5 MINUTES AFTER UTILITY SOURCE IS RESTORED PV ARRAY:2.75 PSF Drawn by:New@engineerinc.io DATE:0611312022 Project Name: PRODUCTS: Larry G Noble RA I LS:S N A P N RA C K Property Adress: MOUNTS:SNAPN RACK 7381 Jackson St NE ROOF MOUNT Fridley, MN 55432 Project: Scale: PV SYSTEM AS INDICATED D 14.0 h MDEPARTMENT OF Y LABOR AND INDUSTRY Wiring Methods and Disconnecting Means ❑ Are the conductor and cable ampacities determined at 125%before adjustment factors?690.8(B) Solar PV Inspection Checklist ❑ How are the PV Source and Output Circuit protected from overcurrent?690.9 ❑ Do AC or DC OCPD's have the appropriate voltage,current and interrupt ratings?690.9 Solar PV Inspection Checklist for REI #ELE- Installer Wolf Rlver Electric Job Address7381 Jackson St NE City/Township Fridley, MN 55432 ❑ Has arc-fault circuit protection been provided for DC source and/or output circuits?690.11 Required Documentation ❑ Is a rapid shutdown required and if so, how is it accomplished and identified?690.12&690.56(C) •Manufacturer's specifications for the inverter Q Is the PV disconnect permanently marked and installed in a readily accessible location?690.13 •Manufacturer's specifications for the module •Manufacturer's specifications for the optimizer(if used) Q Are the Isolating devices or equipment disconnecting means installed in circuits connected to •Verification that the racking system grounding and bonding is listed equipment at a location within the equipment,or within sight and 10 feet of the equipment?(Where PV Inverter the maximum circuit current is greater than 30 amperes an equipment disconnecting means shall be CONTRACTOR provided for isolation.)690.15 ❑ Is the PV system utility-interactive,stand alone or multimode?690.2 Q Has the fuse disconnecting means, if required, been installed?690.15 and 240.40 ❑ Is all the equipment listed for PV application?690.4 ❑ Are PV source or output circuits>30 volts in a raceway or guarded if readily accessible?690.31 WOL�RIVER ❑ Is the system grounded, ungrounded or(functionally grounded)?690.2 and 690.41 ❑ Is single conductor cable used outdoors Type USE-2 or listed &labeled PV wire?690.31 ELECTRIC ❑ Has DC Ground-Fault Protection been provided and properly labeled?690.41(B)? ❑ Are PV source or output circuits on or inside a building in a metal raceway and marked?690.31 Xcel Energy Application#05125633 ❑ What is the maximum PV system voltage?690.7 ❑ Is all listed equipment rated for the maximum voltage?690.7 Interconnection Wolf River Electirc ❑ Determine the maximum circuit current for the PV Source and Output Circuit; Inverter Output Circuit; Q Has a plaque or directory been installed at each disconnecting means(capable of interconnection) Address:101 Isanti Parkway Inverter Input Circuit; and DC to DC Converter Output(refer to inverter documentation). 690.8 NE, Isanti, MN 55040 denoting all electric power sources&power production sources. 705.10 Phone number: (763)229-6662 ❑ Has the point of connection to other sources been installed per 705.12? E-mail:contact(a_wolfriverelectric.com System Grounding ❑ Is the supply side disconnect readily accessible and within 10'of the connection point?705.11 ❑ Are all exposed non-current carrying metal parts of the PV system grounded?690.43 and 690.47 Q Are the utility interactive inverters connected to the system through a dedicated circuit breaker or PV INSPECTION ❑ Are the mounting structures or systems used for equipment grounding?690.43 fusible disconnecting means?705.12 CHECKLIST ❑ Does the bus or conductor ampacity comply with 705.12? ❑ Are the interconnecting devices used for equipment grounding listed and identified?690.43 ❑ Are the EGC properly sized and protected if exposed and not smaller than#6?690.45,690.46, Q Have all the required labels been applied? (See separate label list.) 690.50, 250.122, 250.120(C) ENGINEEr-:2INC Drawn by.New@engineerinc.io ❑ Has the grounding electrode system been installed?690.47 DATE:0611312022 ❑ If both are present, has the DC grounding electrode system been bonded to the AC GES?690.47(A) P Larry Larry G Noble Property Adress: 7381 Jackson St NE 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.gov Fridley, MN 55432 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.Qov solar-checklist NEC20205olar_Checklist_Checked 20200317 Project: Scale: 1 2 PV SYSTEM AS INDICATED D 15.0