Loading...
HomeMy WebLinkAboutFinal DECK Review 7528 Arthur St APPROVED Jensen D08/19/2022 Brown - Top View Ledger attachment to house per R507.9.1 .3 2020 1 RC HOUSE Ledger 2x10 w/ 5" LedgerLok Provide deck attachment for lateral support, min (2) Per section R507.9.2 2020 1 RC. Joists - 2x8 @ 12" OC Stair Stringers 2x12 @ 9 QC PROVIDE STAIRWAY ILLUMINATION Beam Calc's ' 7'x 6' x 50 lbs= 2100 lbs 10, Okay per plan 12' MAX STAIR RISE; 7 3/4" MIN TREAD ; 10" Full, positive be ring to posts PROVIDE A GRIPABLE 1/16" 6' 8 11/16" 6' 8 11/16" HANDRAIL WITH 4 OR MORE STAIRS. 771 6x6 posts Drop Beam - (2) 2x10 1 Max 24" MAX RAIL SPACING 4" MIN GUARD HEIGHT; 36" BUILD GUARDS TO WITHSTAND MIN. 24' 200LB LATERAL FORCE Details: - Footings to be Diamond Pier Dp-50 - Posts to be 6x6 treated - All framing to be green treated So. Pine - All fasteners, hangers, connectors to be Simpsoon Strong-Tie - Trex Transcend collection decking - Westbury aluminum railing - Stair risers to be no more than 7.75", treads to be 11", no more than 3/8" difference in any riser BROWN - Front View (2) 2x10 drop beam Positive connection Blocking or metal connector between posts and beam tying beam to joists 6x6 posts Diamond Pier DP-50 BROWN - Left View oo oo oo Stairs - Riser no more than 7.75" - Tread to be I - No more than a 3/8" difference in any riser - Railing to be between 34-38" high 2x12 stair stringers @ 9"OC BROWN - Right View Westbury aluminum railing Trex Transcend Decking 2x8 Joists @ 12" OC TLeder 2x 10 " LedgerLO K Deck Height roughly 10'