HomeMy WebLinkAboutFinal DECK Review 7528 Arthur St APPROVED
Jensen D08/19/2022
Brown - Top View
Ledger attachment to house per R507.9.1 .3 2020 1 RC
HOUSE
Ledger 2x10 w/ 5" LedgerLok
Provide deck attachment for lateral support, min (2)
Per section R507.9.2 2020 1 RC.
Joists - 2x8 @ 12" OC
Stair Stringers
2x12 @ 9 QC PROVIDE STAIRWAY ILLUMINATION Beam Calc's ' 7'x 6' x 50 lbs= 2100 lbs 10,
Okay per plan
12'
MAX STAIR RISE; 7 3/4"
MIN TREAD ; 10"
Full, positive be ring to
posts
PROVIDE A GRIPABLE 1/16" 6' 8 11/16" 6' 8 11/16"
HANDRAIL WITH 4 OR MORE
STAIRS. 771
6x6 posts Drop Beam - (2) 2x10 1
Max 24"
MAX RAIL SPACING 4"
MIN GUARD HEIGHT;
36"
BUILD GUARDS TO
WITHSTAND MIN. 24'
200LB LATERAL
FORCE
Details:
- Footings to be Diamond Pier Dp-50
- Posts to be 6x6 treated
- All framing to be green treated So. Pine
- All fasteners, hangers, connectors to be Simpsoon Strong-Tie
- Trex Transcend collection decking
- Westbury aluminum railing
- Stair risers to be no more than 7.75", treads to be 11", no more than 3/8"
difference in any riser
BROWN - Front View
(2) 2x10 drop beam
Positive connection Blocking or metal connector
between posts and beam tying beam to joists
6x6 posts
Diamond Pier
DP-50
BROWN - Left View
oo
oo
oo
Stairs
- Riser no more than 7.75"
- Tread to be I
- No more than a 3/8" difference in
any riser
- Railing to be between 34-38" high
2x12 stair stringers
@ 9"OC
BROWN - Right View
Westbury aluminum railing
Trex Transcend Decking 2x8 Joists @ 12" OC
TLeder 2x 10
" LedgerLO K
Deck Height
roughly 10'