Loading...
HomeMy WebLinkAboutGORDON L WILLIS Solar Drawings wStamp 09 14 2022 GENERAL NOTO CONTRACTOR 1. All electrical materials shall be new and listed by recognized SITE MAP& PV LAYOUT PV 1.0 Address:101 Isanti Parkway WOL R 1 V E R electrical testing laboratory ELECTRICAL 1-LINE DIAGRAM PV 2.0 I HEREBY CERTIFY THAT THIS PLAN, NE, Isanti, MN 55040 Custom made equipment shall have complete test data submitted SPECIFICATION, OR REPORT WAS PREPARED Phone number: (763)229-6662 ELECTRIC SYSTEM LABELING DETAIL PV 3.1 E-mail: contact(a�wolfriverelectric.com by the manufacturer attesting to its safety PLACARD PV 3.2 BY ME OR UNDER MY DIRECT SUPERVISION 2. Outdoor equipment shall be NEMA 3R rated or equivalent PROPERTY PLAN PV 4.0 AND THAT I AM A DULY LICENSED Xcel Energy Application#05197995 3. All metallic equipment shall be grounded ATTACHMENT LAYOUT PV 5.1 PROFESSIONAL ENGINEER UNDER THE LAWS 4. Contractor shall obtain electrical permits prior installation and OF THE STAT NESOTA. Owner: GORDON L WILLIS P P ATTACHMENT DETAIL PV 5.2 shall coordinate all inspections, testing commissioning and INVERTER DATA SHEET D 6.0 SIGNATURE: Property Address: 5044 3rd St NE Fridley, MN 55421 acceptance with the client, Property Type: Single Family Residence utility co. and city inspectors as needed. ENPHASE RAPID SHUTDOWN D 7.0 NAME: MANOUCHEHR HAKHAWAANESHI Drawn by: New@engineerinc.io 5. The electrical contractor shall verify the exact locations of service MODULE DATA SHEET D 8.0 DATE: I LICENSE NUMBER: 58681 Date: 0911312022 points and service sizes with the serving utility company and RACKING DATA SHEET D 9.0 Date Certified and comply with all utility companies requirements. ATTACHMENT DATA SHEET-D 10.0 Signed: 09/14/2022 VICINITY MAP (SCALE: NTS) 6. Drawings are diagrammatic only, routing of raceways shall be option of the contractor unless otherwise noted and shall be INVERTER CERTIFICATION D 11.0 coordinated with other trades. SURGE PROTECTION D 12.0 7. If the roof material or the roof structure not adequate for PV WITNESS TEST D 13.0 installation, call the engineer of record print to installation. The PV INSPECTION CHECKLIST D 14.0 contractor is responsible to verify that the roof is capable of CONTROLLER 2 DATA SHEET-D 15.0 withstanding the extra weight. MILBANK DATA SHEET D 16.0 8. If the distances for cable runs are different than shown, the a GOVERNING CODES s contractor shall notify the electrical engineer to validate the wire m size. Final drawings will be red-lined and updated as appropriate. THE INSTALLATION OF SOLAR ARRAYS AND 9. Whenever a discrepancy in quality of equipment arises on the PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH 930-11151 NE,111 BEY drawing or specifications, the contractor shall be responsible for THE FOLLOWING CODES: MN 55421,U5A providing and installing all materials and services required by the • 2020 National Electrical Code strictest conditions noted on the drawings or in the specifications • 2018 International Building Code to ensure complete compliance and longevity of the operable • 2018 International Residential Code system required by the engineer of record. • 2020 Minnesota Residential Code • 2020 Minnesota Building Code a • 2020 Minnesota Energy Code PHOTOVOLTAIC NOTES: • 2020 Minnesota Accessibility Code �• ••• • 2020 Minnesota State Fire Code 1. Rooftop mounted photovoltaic panels and modules shall be tested, • 2018 International Fire Code listed and identified by recognized testing laboratory • 2018 International Energy Conservation Code 2. Solar system shall not cover any plumbing or mechanical vents • 2018 Mechanical Code 3. Modules and support structures shall be grounded AS ADOPTED BY THE STATE OF MINNESOTA unless racking has integrated ground. ALL OTHER ORDINANCE ADOPTED BY THE 4. Removal of an interactive inverter or other equipment shall not LOCAL GOVERNING AGENCIES SATELLITE VIEW (SCALE: NTS) disconnect the bonding connection between the grounding SYSTEM RATING electrode conductor and the photovoltaic source and/or output - I circuit grounded conductors. DC 9.60 KW STC 5. All PV modules and associated equipment and wiring shall be AC 6.96 KW STC protected from physical damage. • 4J 6. Live parts of PV source circuits and PV output circuits over 150v to EQUIPMENT SUMMARY j ground shall not be accessible to other than qualified persons 24 HANWHA 400 WATT MODULES while energized. WITH IQ8+ MICROINVERTERS 7. Inverter is equipped with integrated DC disconnect, thus providing 1 x IQ CONTROLLER 2, t' ground fault protection f 8. All conductors shall be copper and 75 deg rated ECTRICAL INFORMATION : 9. A single conductor shall be permitted to be used to perform the m multiple functions of grounding, AC grounding and bonding EXISTING P g g g g g between AC and DC systems. MAIN SERVICE PANEL BUS SIZE:100A 10.Non-current carrying metal parts of equipment shall be effectively MAIN SERVICE BREAKER SIZE:100A bonded together. Bond both ends of raceways. MOUNTING SYSTEM: SNAPNRACK CNGINCC�INC BUILDING INFORMATION �" j I• Engineerinc.io, CONSTRUCTION TYPE: V-B OCCUPANCY: R3 303 INGlenoaks Blvd Burbank, CA 91502 ROOF:COMP SHINGLE (747) 333 -5991 Truss 2 x 4 @ 24" O.C. new(cDengineerinc.io N 0. INDEX 4, SECONDARY INTERCONNECTION MSP (E)100A Main Service Panel MM....................(E) Milbank Meter QAwash Aut ^� �Q E PVS......... 125A PV Sub Panel Total Roof Area:1378 W u AC.......(N)60A)60A Utility AC Disconnect o 270 90°Total Module Area:528 PB..............................(N) PVC Box °�o.M� 38.31% of Coverage Q�' �o IQ2....................(N) IQ Controller 2 51st Ave NE JB.......................(N)Junction Box W ........................(N) Microinverter Z 180° Solar Module SCALE: 1/8" = T-0" .............EMT type Conduit A Fire Setback Line n ' ............. FMT type Conduit S504 3rd St NE,Fridley, P B I QC MN 5421,USA MM AC MSP PVS SOLAR MODULES JB 24 HANWHA 400 Watt 9Sunnyma Model#Q.PEAK DUO BLK ML-G10+ Panorama Ave Diamond INVERTER Electrical Services � b � � INVERTER TYPE: Micro: z 4 4PTheinkT 24 Enphase IQ8PLUS m 7 Tattoo shop O Solar PV Array 3 b Model#IQ8PLUS-72-2-US(240V) 51)IhAveNE 2- Hanwha 400 W Modules EQUIPMENT ELEVATION 2 - IQ8+ Microinverters JB CONTRACTOR Pitch:40 Deg Cl Orientation: 270 De 3'fire setback -JB- 0WOLF RIVER ID N ❑a w ELECTRIC b D , �� z v = ° 2 From roof 110, Solar PV Array 2 I l M Milbank 4- Hanwha 400 W Modules � ° Cl Meter ° -° 4 - IQ8+ Microinverters v Controller 1� I Wolf River Electirc Orienttatio O Main atio 0 Degn: 270 Deci ElAddress:101 Isanti Parkway Panel NE, Isanti, MN 55040 LS �0 Phone number: (763)229-6662 utlityAc E-mail:contact(ccilwolfriverelectric.com Dis onned PVC 12x6 L Box El SITE MAP & PV O LAYOUT Solar PV Array 1 18- Hanwha 400 W Modules Note:Keep 3ftclearance from gas meter and AC unit. 18 - IQ8+ Microinverters ENGINEE;:aINC Pitch:40 Deg Orientation: 90 De Drawn by:New@engineerinc.io NOTE: No clearance issue DATE:0911312022 Distance between all equipments is maximum 10" Project Name: GORDON L WILLIS Property Adress: Xcel Energy Application#05197995 5044 3rd St NE Note: 24/ 7 Unescorted keyless access is to be Fridley, MN 55421 provided for ALL UTILITY EQUIPMENT Project scale: NOTE: Conduit in attic shall PV SYSTEM AS INDICATED be minimum 18 inches from roof sheating EPV 1 .0 REFERENCE POINT OF APPLICABILITY Upgrade ExistingMeter to Milbank U4801 U4801 MILBANK NOTE:FOR WIRES SMALLER THAN#1 REMOVE METER SECONDARY INTERCONNECTION LUG AND USE AN APPROVED ULRINGTERMINAL 120/240V, NOTE:Install battery 1 P,3W in garage basement,or IQ System Controller 2 4/0-4/0-4/0 AL 0 utility room away from 14.52A harsh weather 200A Main Breaker ¢ — + I 125A PV SUB PANEL Wreless Comm!; x 0000 0000 0000 U 0000 0000 0000 z Z) 0000 0000 0000 0000 0000 0000 of ❑00❑ 0000 0000 IQ Battery Autotransfor r m — ❑00❑ 0000 0000 70A 20A U 1'100❑ 2'1000 2000 00 INSTALL(2)20A PV IQ Combiner Generator 7.26A 2-POLE C/B NON CENTER100A _ J BOX Auxiliary 20� MAIN C/B NEMA3R Contact -1 11102 NC1 NC2 NO NC4 NO3 mUU — 4/0-4/0-4/0 AL 0 0000l ll 11U 0 ❑00❑ T T T #4 CU GND z 50 U6' ¢ U0 36.3A0 0 EXISTING 00 100A 2.42A a °O J BOX SERVICE NEMA3R 000 SUB _ _ m PANEL 2 m ❑DO❑ 0000 U ❑00❑ 0000 ��!MNSPD-300-AC urge Protection OA NON-FUSED AC DISCONNECT, Lu Terminal 120/240V, z C) ❑00❑ 0000 UTILITY AC DISCONNECT 1P,3W ¢ U 0000 0000 Rapid Shutdown 0000 0000 VISIBLE-OPEN m — 0000 0000 LOCKABLE,READILY ACCESSIBLE Switch U lit '1000 2'1000 (3)#8 T,2 THWN/THWN-2 NEMA3R 120/240V 1P 3W 4.84A (1)#8 AWG GND g J Box 3/4"EMT 2 FEET — — — NEMA3R _ (4)#10 AWG THWN/THWN-2 x m 0000 0000 00❑00 (1)#8 AWG7 GND FEET (3)#8 AWG THWN/THWN-2 U 0000 0000 0000 3/4"EMT z 0000 0000 30000 (1)#8 AWG GND En hase Comm Kit ¢ U 0000 0000 0000 0000 0000 0000 3/4"EMT 2 FEET m — 0000 0000 30000 (4)#10 AWG THWN/THWN-2 U 1�000 2J000 0000 410000 (1)#BAWGGND CONTRACTOR 3/4"FM T 20 FEET Consumption TS Cell Kit ENPHASE Q CABLE 2 #14 AWG THWN/THWN-2 (2)#12 AWG PV WI RE (1)#6 AWG EGC FREE IN THE AIR - WOL�RIVER ELECTRIC PVC 12x6 Box PV MONITORING DEVICE NOTE:AC DISCONNECT VISIBLE AND LOCKABLE Wolf River Electirc Note: Relocate Envoy from Address:101 Isanti Parkway IQ Combiner to the panel with loads J NE, Isanti, MN 55040 Phone number: (763)229-6662 E-mail: ;ontact(awolfriverelectric.com Note:Keep 3ft clearance from gas meter and AC unit. PVARRAYRATING WIRE SIZE CALCULATION ELECTRICAL 1-LINE BRANCH CIRCUIT-A BRANCH CIRCUIT-A DIAGRAM Number Modules 12 Type Q.PEAK DUO BLKML-G10+ Honwho 400 Watt Number OF Microinverters in Circuit 12 Xcel Energy Application#05197995 NumberMicrolnverters 12 Type EnphoselQ8+Microinverters IQ8PLUS-72-2-US(24OV) Microinverter Maximum Output Current(A) 1.21 Note: 24/7 Unescorted keyless access is to be Total DC Wattage(Watts) watts STC,,(Watts/Module)12*400=4800 Branch Circuit Total Current(A) 12*1.21*1.25=18.15 y Array Currents I-SC 11.14 JA I 1-MP 1 10.77 JA Breaker5ize Per Branch Circuit(A) 20 provided for ALL UTILITY EQUIPMENT Module Voltage v-Oc I 45.3 IV I V-MP 1 37.13 IVCNGINCC�INC Design meet National Electric COde(NEC codes) BRANCH CIRCUIT-B BRANCH CIRCUIT-B Number Modules 12 Type Q.PEAK DUO 13LKML-G10+ Hanwho 400 Watt Number OF Microinverters in Circuit 12 Drawnby.New@engineerinc.io DC 9.60 KW STC NumberMicrolnverters 12 Type EnphoselQ8+Microinverters IQ8PLUS-72-2-US(24OV) Microinverter Maximum Output Current(A) 1.21 DATE:0911312022 AC 6.96 KW STC Total DC Wattage(Watts) Watts STC,(Watts/Module)12*400=4900 Branch Circuit Total Current(A) 12*1.21*1.25=18.15 24 HANWHA 400 WATT MODULES Project Name: Array Currents I-SC 11.14 A 1-MP 10.77 A Breaker5ize Per Branch Circuit(A) 20 24 ENPHASE IQ8PLUS MICROINVERTERS SYSTEM RATING AND DER POWER OUTPUT Module Voltage V-OC 1 45.3 1 V V-MP 37.13 V GORDON L WILLIS ENPHASE IQ8PLUS MICROINVERTERS DC 9.60 KW STC FROM JBOX TO ENPHASE COMBINER BOX Property Adress: 1 PHASE 290VA AC 6.96 KW STC Maximum Continius Current(A) 18.15 More Than3CCCAdjist.Fador 0.8 Adjusted ConductorAmpacity(A) 18.16/0.8=22.69 50443rd St NE AC PORT BACKFEED CURRENTT OA INVERTER MAXIMUM CONTINUOUS OUTPUT:290VA ) fwire( ) MAXIMUM OUTPUT CURRENT A INVERTER:ENPHASE S-72-2-US Raceway Height FromRoof(Temp39+22=61C 31/2" #o #BC*2 4 AmblendTem Factor Per NEC Table 31ai5()()() y' b 2 a 0.71 Fridley, MN 55421 ONTI SYSTEM POWER OUTPUT:24 x 290=6.96 Temp.Derate Factor(max.continous current divided ambient tem.Factor(A) 22.69*0.71=31.95 Wire Size from NEC Table 310.15(b)16 10AW 1 project: Scale DC SHORT CIRCUIT CURRENT 15A FROM ENPHASE COMBINER BOX TO IQ CONTROLLER PV : SYSTEM AS INDICATED Total Number OfMicroinverters 24 TotalAmpsFromAllMicroinverters (A) 24*1.21=29.04 Consider Continuous(A) 29.04 1.25=36.3* Temp.Derate Factor(0.91 at wall of the Building)(A) 36.3/0.91=39.89 Wire Size from NEC Table 31a15(b)16 8AWG �\ , .O Ambiend Tem Factor Per NEC Table 31a 15(b)(2)(a) 0.91 V WARNING NOMINAL OPERATING AC VOLTAGE � NOMINAL OPERATING AC FREQUANCY � TURN OF PHOTOVOLTAIC MAXIMUM AC POWER � AC DISCONNECT PRIOR TO MAXIMUM AC CURRENT � WORKING INSIDE PANEL MAXOCERCURRENTDEVICERATING - FOR AC MODULE PROTECTION Photovoltaic Power Source DO NOT DISCONNECT PV SYSTEM DC DISCONNECT © LABEL2 UNDER LOAD - OPERATING CURRENT •X LABEL9 OPERATING VOLTAGE - CAUTION: SOLAR CIRCUIT MAXIMUM SYSTEM VOLTAGE - MAINF MNECT © WARNINGLABEL10 LABEL20 © ELECTRIC SHOCK HAZARD© MAIN PV SYSTEM RATED MAX POWER-FONT CURRENT � PV SUB-PANEL RATED MAX POWER-FONT VOLTAGE � THE DC CONDUCTORS OF THIS AC DISCONNECT MAXIMUM SYSTEM VOLTAGE PHOTOVOLTAIC SYSTEM ARE SHORT CIRCUIT CURRENT � O UNDERGROUNDAND MAY BE =I L,1=I FA=1 LABEL11MAX RATED OUTPUT CURRENT OF - THE CHARGE CONTROLLER IF INSTALLED © LABEL4 _ SOLAR DISCONNECT WARNING AC © ELECTRIC SHOCK HAZARD© CONTRACTOR CAUTION • WITH DISCONNECTGROUND FAULT IS INDICATED SOLAR ELECTRIC SYSTEM RAPID SHUTDOWN ® NORMALLY GROUNDED CONDUCTORS CONNECTED II MallNDERGROUND AND ENERGIZED D SHUTDOWN TO THE • • POSITION TO SHUT WN PV SYSTEM LABEL5WARNING-DUAL POWER SOURCE •• SECOND SOURCE IS PV SYSTEM •• HAZARDREDUCE © WARNING © ELECTRIC SHOCK HAZARD CAUTION LABEL 14 IN THE ARRAY. DO NOT TOUCH TERMINALS PHOTOVOLTAIC SYSTEM CIRCUITWolf River Electirc IleTERMINALS ON BOTH LINE AND LOAD IS BACKFED SIDES MAY BE ENERGIZED IN THE OPEN NE,••Isanti, MN 55040 POSITIONLABEL 15 Phonenumber: MAIN SERVICE E-mail:contact�D_wolfriverelectric.com PANEL PHOTOVOLTAIC AC DISCONNECT ® LABEL6MAXIMUM AC OPERATING CURRENT O O WARNING © LALBAEL 16 LABELING DETAIL AC OPERATING CURRENTSYSTEM ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS PHOTOVOLTAIC TERMINALS ON BOTH1=11sIV I AND LOAD SIDES MAY BE ENERGIN THE OPEN POSITION UTILITY AC DISCONNECT Drawn -- DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES LABEL 17 DATE:0911312022 Pmject Name ARE EXPOSED TO SUNLIGHT PHOTOVOLTAIC •' • N L WILLIS FrProject :]I Scale idley, DISCONNECT Note: 690 PV SYSTEM AS INDICATED CAUTION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: DISCONNECTS LOCATED AS SHOWN: SERVICE 1 OF 2 SERVICE 2 OF 2 IQ CONTROLLER IQ CONTROLLER CONTRACTOR PVC 12X6 BOX PVC 12X6 BOX SERVICE POINT & AC DISCONNECT SERVICE POINT & AC DISCONNECT o UTILITY METERING ENPH E MBINER UTILITY METERING ENPHA E COMBINER WOL�RIVER SOLAR PV ARRAY SOLAR PV ARRAY ELECTRIC 0 0 o o Wolf River Electirc 0 \:Z� Address:101 Isanti Parkway ° ° NE, Isanti, MN 55040 Phone number: (763)229-6662 E-mail: ;ontact(a�wolfriverelectric.com 0 0 N N 0 0 W \ � E W E PLACARD 5044 3rd St NE 5044 3rd St NE ENGINEE�INC Drawn by:New@ Fridley, MN 55421 S Fridley, MN 55421 S DATE 0911312022gineerinc.io Project Name: GORDON L WILLIS Property Adress: 5044 3rd St NE Fridley, MN 55421 Project: Scale: PV SYSTEM AS INDICATED F_PV 3.2 N o° LEGEND Q MSP................ Main Service Panel MM ........................Milbank Meter D PVS..........................PV Sub Panel W 0� E PB....................................PVC Box 270 n rI 90° CN�1 NCC�I N� IQ2..........................IQ Controller 2 aEngineerinc.io, AC............ Utility AC Disconnect 303 N Glenoaks Blvd d Burbank, CA 91502 Aso° (747)333-5991 SCALE: 3/32" — T-0" new _engineerinc.io 93'-5" 1 HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED V_ V V_ PB v- IQC V_ V- V, BY ME OR UNDER MY DIRECT SUPERVISION PROPERTY LINE= V, MM' v, AC V_ I V_ V_ AND THAT I AM A DULY LICENSED V_ MSP $'-9" V' V, PROFESSIONAL ENGINEER UNDER THE LAWS V_ V_ V V_ V_ PVS V_ V_ V, V, V, V_ OF THE STAT NESOTA. V_ V W 25'w SIGNATURE: 36' `� I NAME: MANOUCHEHR HAKH ANESHI V, V, V_ V_ V, V_ V, V_ � DATE: I- 1 LICENSE NUMBER: 58881 V_ V, V_ W V Date Certified and V, V \11 \4- 1 V, W V_ Signed: 09/14/2022 V, V, V_ V_ V_ o El V_ V_ V_ V, CONTRACTOR V, ,, `_ V- V_ ° 00 V_ V, V, V_ WOLF RIVER 60' � V_ � V_ V_ � V_ V, V, 60' ELECTRIC V, ❑ V_ V_ Wolf River Electirc V_ V_ V_ V, Address:101 Isanti Parkway ° V, NE, Isanti, MN 55040 V, Phone number: (763)229-6662 w E-mail:contact(a)_wolfriverelectric.com z Driveway V_ 17'-11" I "' o PROPERTY PLAN V, 93'-5" ENGINEEr-ZINC Drawn by.New@engineerinc.io DATE:0911312022 Project Name: GORDON L WILLIS Property Adress: 5044 3rd St NE Fridley, MN 55421 Project: Scale: Xcel Energy Application#05197995 PV SYSTEM AS INDICATED Note: 24/ 7 Unescorted keyless access is to be provided for ALL UTILITY EQUIPMENT PV 4.0 MODULES ON ROOF DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Prior to the commencement of work, the contractor shall verify the existing roof and framing Solar Modul Modules: Module Weight(Ibs) 48.4 conditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction. 24 #Of Modules 24 Prior to the commencement of work, the contractor shall inspect framing for any damage Attachment Truss 2 x 4 @ 24"O.C. Max Distributed Load: 3 PSF Total Module Weight(Ibs) 1161.E such as water damage, cracked framing, etc. and These Plans are stamped for structural Plywood &Building Felt Rack Weight(Ibs) 232.32 code compliance of the roof framing supporting the proposed PV installation reference only. Microlnverters Weight(Ibs) 57.12 These plans are not stamped for water leakage. PV modules, racking, and attachment 1 Layer of COMP SHINGLE Total System Weight(Ibs) 1451.04 components must follow manufacturer guidelines and requirements. Attachments to be #Of Standoffs 62 installed in a staggered orientation to properly distribute loads. Max Span Between Standoffs (in) 48 Xcel EnergyApplication#05197995 Loading Per Standoff(Ibs) 23.41 pp Total Area (sq.ft.) 528 Note: 24/7 Unescorted keyless access is to be Loading (PSF) 2.75 provided for ALL UTILITY EQUIPMENT I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS CNGINCC�I NC OF THE STAT NESOTA. Engineerinc.io, SIGNATURE: ATTACHMENT 303 N Glenoak5 Blvd NAME: MANOUCHEHR HAKHAAANESHI RAIL Burbank, CA 91502 DATE: I LICENSE NUMBER: 58681 (747) 333- 5991 Date Certified and — — — — — — — — — — — — — — — — Truss 2 x 4 @ 24" O.C. news-engineerinc.io Signed: 09/14/2022 SNAPNRACK,ULTRA RAIL SPEEDSEAL TM FOOT CONTRACTOR PARTS LIST — — — — — — — — — — 1.86" �1.08"-1.37" ITEM QTI DESCRIPTION WOLF RIVER (`�,�Q' 10.3811 1 1 SNAPNRACK,SPEEDSEAL FOOT,BASE,SEALING,SILVER/BLACK 2 1 BOLT,FLANGE,SERRATED,5/16IN-18 X 2IN,SS ELECTRIC 1" 3 1 SNAPNRACK,RL UNIVERSAL,MOUNT SPRING,SS 0 3. 5" 8" 4 1 SNAPNRACK,ULTRA RAIL MOUNT THRU PRC,CLEAR/BLACK 11 1 78" 5 1 SNAPNRACK,ULTRA RAIL MOUNTTAPPED PRC,CLEAR/BLACK 0.25" MATERIALS: DIE CAST A380 ALUMINUM,6000 SERIES ALUMINUM,STAINESS STEEL Ft — I DESIGN LOAD(LBS): 802 UP,1333 DOWN,357 SIDE OPTIONS: 2.24" — 3.20"' ULTIMATE LOAD(LBS): 2118 UP,4006 DOWN,1331 SIDE CLEAR/BLACK 0.17" 2 58" Wolf River Electirc TORQUE SPECIFICATION: 12 LB-FT — CERTIFICATION: UL 2703,FILE E359313;WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 Address:101 Isanti Parkway NE, Isanti, MN 55040 / R .33"1.12 WEIGHT(LBS): 0.45 Phone number: (763)229-6662 R1.12" — - - - - — 1. 1" R 0.82" — — — — E-mail:contact(a_wolfriverelectric.com 1. 9" ATTACHMENT s - - - - - - - � - - - - - - LAYOUT -1.50"- 4 16'-4" CENGINCCr-ZINC 2 1 1 8'_2tt Drawn by:New@engineerinc.io DATE:0911312022 Project Name: GORDON L WILLIS Property Adress: 5044 3rd St NE Fridley, MN 55421 Project. Scale: PV SYSTEM AS INDICATED PV 5. 1 SNAPNRACK UR SPEEDSEAL FOOT FOR MODULE HEIGHT OFF ROOF,RANGE: COMPOSTION ROOF MOUNTING UR-40:3%"-�,4. COMP SHINGLE ROOFING,TYP. REFER TO SNAPNRACK ENGINEERING CHARTS UR-60:4"-5" SNAPNRACK UR SPEEDSEAL FOOT FOR APPLICABLE RAIL SPANS. ROOF DECKING,TYP. SI6`0 S.S. LAG SCREW MUST EMBED A MIN. SNAPNRACK, SNAPNRACK,�/16"O S.S. OF 21A" INTO STRUCTURAL MEMBER ULTRA RAIL LAG SCREW,TYP. STRUCUTRAL MEMBER, REFER TO SNAPNRACK INSTALLATION WOOD RAFTER,TYP. MANUAL FOR Ye'0 HARDWARE TORQUE SPECIFICATIONS STRUCTURAL MEMBER SPECIFICATIONS: MINIMUM WOOD GRADE= SPF#2 MINIMUM SPECIFIC GRAVITY= 0.42 ALLOWABLE FASTENER UPLIFT =820 LBS CONTRACTOR ALLOWABLE FASTENER LATERAL= 2S0 LBS MINIMUM FASTENER ED(iiE DISTANCE= 0.5" MINIMUM FASTENER END DISTANCE= 2.2" WOL�RIVER 21!" MIN.EMBEDMENT INTO WOOD MEMBER ELECTRIC SNAPNRACK,ULTRA. RAIL MOUNT, TAPPEDi6"WASHER,S.S. (MAY INCLUDE NEOPRENE TYPE GASKET) Wolf River Electirc PENETRATION DETAIL Address:101 Isanti Parkway NE, Isanti, MN 55040 Phone number: (763)229-6662 E-mail: ;ontact(awolfriverelectric.com SNAPNRACK, ULTRA COIL SPRING FOR 3 "0 BOLT, S.S. RAIL MOUNT,THRU �� OPTIONAL CAVITY IN UR SPEEDSEAL FOOT IS FILLED WITH SEALANT TO ENCAPSULATE AND PROTECT THE ROOF PENETRATION ATTACHMENT 5/16"0-18 X 2"BOLT, FROM MOISTURE DETAIL C SERRATED FLANGE,S.S. SNAPNRACK, SPEEDSEAL FOOT, BASE,SEALING ENGI NEEr-:Z INC EXPLODED Drawn by.New@engineerinc.io DATE:0911312022 SEALANT Project Name: GORDON L WILLIS Properly Adress: 2%^ 5044 3rd St NE 1 ROOF DECKING; Fridley, MN 55421 Ll Project: Scale: PvSYSTEM L AS INDICATED UR-40 RAIL I UR-60 RAIL STRUCTURAL MEMBER(RAFTER)FOR USE WITH SNAPNRACK ULTRA SERIES RAILS - - FPV 5.2 ENPHASE E= IQ8 and IQ8+ Microinverters INPUT DATA r .r Commonly used module pairings' w 235-350 235-440 Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPTvoltagerange V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currents[module Isc] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded army:No additional DC side protection required:AC side protection requires max 20A per branch circuit OUTPUT DATA 1: 1: Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 1.0 CONTRACTOR Nominal frequency Hz 60 IQ8 and I Q 8+ Microinverters Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit" 16 13 Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Total harmonic distortion `5% WOLR 1 V E R defined microinverters with split-phase power conversion capability to convert DC overvoltageclass AC port III power to AC power efficiently.The brain of the semiconductor-based microinverter Easyto install ELECTR I C is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with AC port backfeed current mA 30 microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting 1.0 55nm technology with high speed digital logic and has super-fast response times Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Peak efficiency 97.5 97.6 energy systems. • Faster installation with simple CEC weighted efficiency % 97 97 two-wire cabling Night-time power consumption mw 60 Wolf River Electirc Enphase MECHANICAL DATA Address:101 Isanti Parkway - High productivity and reliability Ambient temperature range -400Cto+600C(-400Fto+1400F) NE, Isanti, MN 55040 Produce power even when the Relative humidity range 4%to 100%(condensing) Phone number: (763)229-6662 yearilmned grid is down E-mail: ;ontact@wolfriverelectric.com Ir L_ -'-Ty DC Connector type MC4 • More than one million cumulative Part of the Enphase System.tem.IQ8Series IQ8 Series Microinverters redefine Dimensions(HxWxD) 212mm(8.3")x175mm(6.9'7x30.2mm0.2'7 P y hours of testing Microinverters integrate with the EnphaseIQ standards with more than one million Weight 1.08 kg(238 lbs) Battery.Enphase IQ Gateway,and the Enphase cumulative hours of power-on testing. Class lldouble-insulated INVERTER Appmonitoring and analysis software. enabling an industry-leading limited warranty enclosure Cooling Natural convection-nofans of up to 25 years. Optimized for the latest high- Approved for wet locations Yes DATA SHEET powered PV modules Acoustic noise at 1 m <60 dBA Pollution degree PD3 ep=4z CERTIFIED Microgrid-forming Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Complies with the latest Environ.category/UV exposure rating NEMA Type 6/outdoor advanced grid support , ENG 1 NEED 1 NC ConnectPV modules quicklyand easilyto IQ8 Series Microinverters are UL Listed as Remote automatic updates for CA Rule 21(UL1741-SA)•UL62109-1•UL1741AEEE1547,FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 Drawnby.New@engineerinc.io IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements DATE:0911312022 Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conformswith NEC 2014.NEC 2017.and NEC 2020 section connectors. according to manufacturer's instructions. Configurable to support a wide 69012 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,forAC and DC conductors.when installed according to Project Name: range of grid profiles manufacturer's instructions. GORDON L WILLIS Meets CA Rule 21(UL 1741-SA) Property Adress: ®2021 Enphase Energy.All rights reserved.Enphase the Enphase logo,IQ8 microinverters. (1)No enforced DC/AC ratio.Seethe compatibility calculator at httpsJ/link.enphase.com/ 5044 3rd St N E and other names are trademarks of Enphase Energy.Inc.Data subject to change requirements module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Referto Fridley, MN 55421 IQ8SP-DS-0002-01-EN-US-2021-10-19 local requirements to define the number of microinverters per branch in your area. 1 Q8SP-DS-0002-01-EN-US-2021-10-19 Project: I Scale: PV SYSTEM AS INDICATED LE 6.0 QUICK INSTALL GUIDE ENPHASE Install the Enphase IQ8 Series Microinverter To install Enphase IQ8 Series Microinverters,read and follow all warnings and instructions in this guide and in the Enphase IQ8 Series Microinverter Enphase Energy//Rapid Shutdown Installation and Operation Manual at eenphase-com/suo=Safety warnings are listed on the back page of this guide. The Enphase Microinverter models listed in this guide do not require grounding electrode conductors(GEC),equipment grounding conductors(EGC),or grounded conductor(neutral).The microinverter has a Class II double-insulated rating,which includes ground fault protection(GFP).To support GFP,use only PV modules equipped with DC cables labeled PV Wire or PV Cable Rapid shutdown is built-in IMPORTANT:Enphase IQ8 Series Microinverters require the IQ Cable.An IQ Gateway is required to monitor performance of the IQ Microinverters.The Q Accessories work only with Enphase IQ8 Series Microinverters. Note:After you log in to your Enphase Installer Platform account from Enphase Installer app,Scan the microinverter QR code and connect to the Enphase IQ Gateway to track the system installation progress. The 2014 edition of the National Electrical Code(NEC 2014)added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. NEC 2014,Section 690.12 applies PREPARATION Enphase Microinverters full meet rapid shutdown requirements in the to PV conductors over 10 feetfrom p y p q A Download the Installerpp and o te Enphase A n it to to ) the PV array and requires that the ) p � g D Check that you have these other items:a ir�.� a new code without the need to install any additional electrical equipment. in to your Enphase Installer Platform account.With this []rr � ACjunction box. conductors power down to 30 volts t., app,scan the microinverter QR code and connect to x� • Tools:screwdrivers,wire cutter,voltmeter,torque wrench,sockets, and 240 volt-amperes within 10 r r seconds of rapid shutdown initiation. the Enphase IQ Gateway to track system installation a and wrenches for mounting hardware progress.To download,go to enphase.com/toolkit or scan the QR code at right. E) Protect your system with lightning and/or surge suppression devices.It is also important to have insurance that protects against lightning and String inverters require work arounds for rapid shutdown B) Referto the following table and check PV module electrical compati- electrical surges. bility at:ennhase com/en-uc_/str)po /mod it .pm atp ihility. Model DC connector Typical PV module*cell count IF Plan your AC branch circuits to meet the following limits for maximum CONTRACTOR 18 60 2-US MC 4lockin number of microinverters per branch when protected with a 20-amp Work around. Work around. Q g type Pair with 60 cell/120-half-cell over-current protection device(OCPD) Specialized Rapid Shutdown String Inverter Installed modules electrical box installed on the on roof,a hostile IQBPLUS-72-2-US MCA locking type Pair with 60 cell/120-half-cell,66 Maximum* IQ8 Series Microinverters per AC branch circuit(sin- roof cell,or 72 cell/144-hhalf--cell le- hase roof within 10 feet of array. environment that string g P ' WOL�R 1 V E R IQ8A-72-2-US IQ8(240V IQ8+ 240V IQBM(240V) inverters are not built ) ( ) IQ8H-240-72-2-US MC-4 locking type Pair with 60 cell/120-half-cell,66 Work around. to live in. IQSH-208-72-2-US cell,or72 cell/144-half--cell 16 13 11 ELECTRIC Shutoff switch that Is `Enphase IQ8 Series Microinverters are compatible with bi-facial PV modules if IQ8A(240V) IQ8H(240V) IQ8H(208V) the temperature adjusted electrical parameters(maximum power,voltage and 11 10 9 easily accessible to first current)ofthe modules,considering the front side electrical parameters(i.e.,0% *Limits may vary.Refer to local requirements to defne the number of responders on the ground. back side gain),are within the allowable microinverter input parameters range. microinverters per branch in your area. w it C) In addition to the Enphase Microinverters,PV modules and racking, G) Size the AC wire gauge to account for voltage rise.Select the correct you will need these Enphase IQ8 Series Microinverters: wire size based on the distance from the beginning ofthe Enphase IQ Work around. Enphase IQ Gateway(model ENV-IQ-AM 1-240)communications Cable to the breaker in the load center.Design for a voltage rise total Extra conduit in Installation. Residential String Inverter Commercial String Inverter gateway or Enphase IQ Combiner(check enphase.com for models): of less than 2%for these sections.Refer to the Voltage Rise Technical Wolf River ElectlrC is required to monitor solar production. Brief at ennhase_com/support for more information. Address:101 Isanti Parkway Tie wraps or cable clips(Q-CU P-100) NE, Isanti, MN 55040 Enphase Sealing Caps(Q-SEAL-10):for any unused connectors on Best practice:Center-feed the branch circuit to minimize voltage rise in Phone number: (763)229-6662 the Enphase IQ Cable a fully-populated branch. Enphase Terminator(Q-TERM-10):one needed at the end of each E-mail:contact(a_wolfriverelectric.com Enphase comes standard with rapid shutdown capability AC cable segment Enphase Disconnect Tool(Q-DISC-10) Enphase IQ Cable: ENPHASE RAPID // Cable model Connector PV module Connectors SHUTDOWN Al Enphase microln- Enphase microinverters spacing* orientation per box verters,even those that can safely shut down Q-12-1G-240 1.3m Portrait(al 1) 240 Terminator COMPATIBILITY were previously installed, automatjcally,leaving Q-12-17-240 2.om Landscape(60-and b6-cell) 240 WITH PV inherently meet rapid only low-voltage DC Q-12-20-200 2.3m Landscape(72-cell) 200 shutdown requirements, electricity isolated to *Allows for 30cm of cable slack no additional equipment the PV module CNGINCCZINC or workarounds needed Enphase IQ Cable Drawn by.New@engineerinc.io AC connector DATE:0911312022 DC connector 02021 Enphase Energy.All rights reserved. Enphase,the Enphase logo,Enphase IQ8 Project Name: Residential Microinverter Commercial Microinverter R Series microinverters(IQ8,IQ8+,IQ8A,IQ8H GORDON L WILLIS `Tie wraps or cable clips and IQ8M),Enphase Installer Platform, Property Adress: Enphase IQ Gateway,and other trademarks 5044 3rd St NE or service names are the trademarks of [Fridley, MN 55421 Enphase En Inc.Data subecttochan Y, �—Enphase IQ8 Series Microinverter P Energy, 1 9e r1l enphaser (horizontal installation shown,vertical Rev02-10-23-2021. f Project: Scale: To learn more,visit enphase.com C�J E N E R G Y installation also allowed). IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�I PV SYSTEM AS INDICATED AC junction box 140-00195-02 D 7.0 pOwB � MECHANICAL SPECIFICATION r V Q© Format 74.0In x 41.1in x 126in(including freme) (1879mm x 1045mm x 32mm) 9A0'"B°'""'� ssa-rarsnm•ro mr aa+•°mi Weight 48.5 lbs(22.0 kg) Front Cover 0.131n(3.2mtr)thermally pre-stressed glass with - •°' } anti-reflection technology 4.i °mn -T ed� Back Cover Composite film y�.lsrs„•„t Frame Black anodized aluminum Call 6 x 22 monocrystallne GANTUM solar half cells ® a-araam.ro Junction Box 2.09-3.98inx1.26-2.361nx0.59-0.711n (53-101mm x 32-60mm x15-18mm),IP67,with bypassdiodes ­0 aaam.o Cable 4mm2Solar cable:(+)a49.2in(1250mm),(-)>_49.21n(1250mm) •-a.,•w°a. Connector Staubli MC4:IP88 -��ucaxm°i orrua a•rru dmn o�•'aasm.a T{�Ia•••l.•..a . • , ELECTRICAL CHARACTERISTICS POWERCLASS 365 390 395 400 405 R MANCE AT STANDARD TEST CONDITIONS.STC'(POWER TOLE RANCE*5W/-0W) • Power at MPP' P,p, IW] 385 390 395 400 405 Short Circuit Current' 1. [A] 11.04 11.07 11.10 1114 11.17 Open Circuit Voltage' V M 45.19 4523 45.27 45.30 45.34 fCurrent at MPP Iota, [A] 1o.59 10.65 10,71 10.77 10.83 TOr BBANDtY ' Voltage at MPP Vnw M 36.36 36.62 36.88 1 37.13 37.39 ' Efficiency q [%] a19.6 a19.9 a20.1 z20.4 z2D:6 CONTRACTOR rc' MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' Werlronty Q CELLS Power at MPP P,,w [W] 288.8 292.6 296.3 3001 303.8 prmvRala4era.A• Yield San my E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 L Open Circuit Voltage Voc [VI 42.62 42.65 42.69 42.72 42.76 BREAKING THE 20%EFFICIENCY BARRIER 2 Current at MPP I_ [A] 8.35 a.41 8.46 8.51 8.57 WOL�RIVER Q.ANTUM DUO Z Technology with zero gap cell layout Voltage at MPP Vim° [V] 34.59 34.81 35.03 35.25 35.46 ELECTRIC boosts module efficiency up t0 20.9%. 'Measurement tolerances P_t3%:Iu6 Voa t5%aISTC:1000WIW,25t2°C,AM 1.5accordingto IEC 60904-3•1800W/m1,NMOT,spectrum AM 15 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY m _ --r-----r-----r----�--- Atteast 98%of nominal powerduring Q CELLS is the first solar module manufacturer to ass the most coon rehen- I I I I I p p _ first year.Thereafter max-0.5% save quality programme in the industry:The new"Quality Controlled PV"of •• -------------------------- degradation per year.At least 93.5% of nominal power Up to 10 years.At the independent certification institute TUVRheinland. c least86%ofnominalpowwupto s. W _____________ - 25 es.Fullrwercantles In accordance with n o:g • the Finland teem iofNeQancew I ' I Iaa<ouNcsav/mq o Wolf River Isar i INNOVATIVE ALL-WEATHER TECHNOLOGY Al data within measurement toleranc- d. Optimal yields,whatever the weather with excellent Address:101 Isanti Parkway CELLS Cy ow-light and temperature behavior. sales organisation ofyourrespective R NE, Isanti, MN 55040 country. Phone number: (763)229-6662 rau+s Typical module performance antler low Irtetllence condtlons In ydr ENDURING HIGH PERFORMANCE comparison toSTCcondltlons(25°C,100ow/W) E-mail: ;ontact@wolfriverelectric.com Long-term yield security with Anti LID Technology,Anti PID g- Y Y gY• TEMPERATURE COEFFICIENTS o Technology',Hot-Spot Protect and Traceable Quality Tra.Qlm. Temp: a [%/K) +0.04 Temperature Coefficient of V_ [%/K] -0.27 ? _ s Tempar o i P.:;.- y [%/K] -0.34 Nominal Module Operating Temperature NMOT [°F] 109t5.4(43t3°C) EXTREME WEATHER RATING o CrLyS/`/•j{ High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN MODULE high snow(5400 Pa)and wind loads(4000Pa). Maximum System Voltage V; M 1000(IEC)/1000(UL) PV module classification Classll o DATA SHEET A RELIABLE INVESTMENT Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE 2 9 Max.Design Load,Push/Pulp [Ibs/ft'J 75(3600 Pa)/55(2660Pa) Permitted Module Temperature -40°F up to+185°F p Inclusive 25-year product warranty and 25-year on continuous Duty (-40°C up to 85'C) linear performancewarranty2. Max.Test Load.Push/Pull' [Ibs/ft9 113(54DDPa)/a4(400DPa) °See Instalatlon Manual 'APT data conditions according to IEC ITS 62804-1:2015,method A(-]500V,96h)`See data sheet on rear for further Information QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION ENGINEEv-:2INC 1.11-61730.CEaomcrsra. (V), ,0 0 A � 2 Drawn by:New@engineerinc.io Oumry Covarad PV-TUV(J�mmm. /�A. L�YVIJ- Cl/ o-o I?awl 5 DATE:0911312022 IEC 61215.2016.IEC 61730,2016, [� US.Patent N.0,193.215(s6e cats), i6n Horizontal 76.4in 43.3.in 48.01n 1656lbs 24 24 32 THE IDEAL SOLUTION FOR: acpvicerlmcaaonmgNna packaging 1940mm 1100mm 1220mm 751k pallets pallets rrodulas Pmiect Name: cus P 9 9 9 p &sRaY30n GORDON L WILLIS dent + u iiii�l a ideMlal buildings Properly Adress: Note:Installation Inst cdons must be tolbwed.See the installation and operating manual or contact our technical service department for further Information on approved Installation and use of 5044 3rd St NE this product. Fridley, MN 55421 GICELLS Hameha OCR'Center Drive. aSuit Project: Scale: Engineered In Germany 4005pecirumCen[erDnve,Sutte1400,Irvlre,CA92618,USAITEL+1 949 748 59 96 1EMAILInqulry@s.gtel5.comIWEBwww.rrcelB.us PVSYSTEM AS INDICATED LE 8.0 Snap rack- UR-40 SnapNrack Ultra Rail UR-60 A sleek, straightforward rail solution for mounting solar modules .. types. Ultra Rail Solar Mounting Solutions features two rail profiles; , • is a lightweight rail profile suitable • •st geographic Ultra Rail • - •• • rail . . . . .. . . . .. .. . ... :. compatible with all . . . . clamps, . . . of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge CONTRACTOR Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install WOL�RIVER • Industry best wire management offering ELECTRIC includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard Wolf River Electirc Address:101 Isanti Parkway NE, Isanti, MN 55040 • Phone number: (763)229-6662 Industry ' • • • Wire Mounts • • E-mail: ;ontact(a)_wolfriverelectric.com Management Heavy Duty UR-60 Rail • • • • • _ • UR-60 rail profile provides increased span capabilities for high wind speeds and snow Single loads ��� � RACKING • • • • • • • Taller, stronger rail profile includes profile- Clamps : Accessories specific rail splice and end cap DATA SHEET _ compatible • All existing mounts, module clamps, and accessories are retained for the same great both rail profiles install experience CNGINCC�INC Drawn by.New@engineerinc.io DATE:0911312022 • - • • - • • Ultra • Project Name: GORDON L WILLIS •ionsv area entgiinveereed t.o •maeterrial iuose Property Acress: SQnapNuracak Sloilatr Myou.ntiIngn RESOURCES snapnrack.com/resources F°aeyrMNtS a21 DESIGN snapnrack.com/configurator Project Scale labor - • and improve overall installationquality and safety. Pv SYSTEM L AS INDICATED WHERE TO BUY snapnrack.com/where-to-buy 877-732-2860 • • • • D 9.0 DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: SNAPNRACK, ULTRA RAIL SPEEDSEALTm FOOT mwatkins 5flapHruck" SNAPNRACK, ULTRA RAIL SPEEDSEALTm FOOT mwatkins Sfla NN ack- REVISION: Solar Mounting Solutions REVISION: Solar Mo unting Solutions PART NUMBER(S): PART NUMBER(S): 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,LA 96105 USA 595 MARKET STREET,29TH FLOOR.SAN FRANLISOO,CA 94105 USA A PHONE(415)5W0 900.FAX(415)500.0902 PHONE(415)500b900•FAX(415)5MM2 242-02163, 242-02167 �ENFo.MroKNTHIsoF 9HosoKF9LN� �oaROPR1 .9. N. 242-02163, 242-02167 E .o. �=C""'mu,µo�aoaP. . �.�r 1.37 .30 .38 1.86- 1.08 1.00 v�5a SLOT 3.05 CONTRACTOR 2.78 5 mpNmck 1.78 .25 WOL�RIVER Q L 02.24 � 3.20 ELECTRIC .17 _ _I 2.58 4 3 Wolf River Electirc 0.33 Address:101 Isanti Parkway R1.12 NE, Isanti, MN 55040 Phone number: (763)229-6662 1.21 R•82 E-mail:contacta_wolfriverelectric.com 2 1 ATTACHMENT DATA SHEET PARTS LIST 1.99 ITEM QTY DESCRIPTION 1 1 SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/ BLACK 2 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SS 11 ENG1NEEZINC 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 4 1 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/ BLACK Drawn by:New@engineerinc.io DATE:0911312022 5 1 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/ BLACK 1.50 MATERIALS: DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINLESS STEEL Project Name: GORDON L WILLIS DESIGN LOAD (LBS): 802 UP, 1333 DOWN, 357 SIDE OPTIONS: Property Adre99: ULTIMATE LOAD (LBS): 2118 UP, 4006 DOWN, 1331 SIDE CLEAR/ BLACK 5044 3rd St NE TORQUE SPECIFICATION: 12 LB-FT Fridley, MN 55421 Project: Scale: CERTIFICATION: UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 PV SYSTE L AS INDICATED WEIGHT(LBS): 0.45 ALL DIMENSIONS IN INCHES FD 10.0 CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE Certificate Number 20180530-E341165 Certificate Number 20180530-E341165 Report Reference E341165-20171030 Report Reference E341165-20171030 Issue Date 2018-MAY-30 Issue Date 2018-MAY-30 Issued to: ENPHASE ENERGY INC This is to certify that representative samples of the product as specified on this certificate were tested 1420 N McDowell Blvd according to the current UL requirements. Petaluma CA 94954-6515 Permanently-connected, Grid Support utility Interactive,208V single-phase,240V single phase evaluated for use on a split phase system, distributed resource power system. This is to certify that STATIC INVERTERS, CONVERTERS AND representative samples of ACCESSORIES FOR USE IN INDEPENDENT POWER Models 2-2-U,land IQ7 -72, and IQ7X 96,followed by 2,-5, B,or ACM,followed by US+. Models IQ7PD-72-2-US and IQ7PD-842-US. SYSTEMS, PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT USUCNL—Photovoltaic Rapid Shutdown Equipment. See Addendum Models IQ7-60,IQ7PLUS-72, and IQ7X-96,followed by-2,-5,-B,or-ACM,followed by-US+. Models CONTRACTOR IQ7PD-72-2-US and IQ7PD-84-2-US. Have been investigated by UL in accordance with the +may be followed by additional characters not affecting safety Standard(s) indicated on this Certificate. WOL�RIVER Standard(s)for Safety: ELECTRIC Standard(s)for Safety: See Addendum UL 62109-1,SAFETY OF POWER CONVERTERS FOR USE IN PHOTOVOLTAIC POWER Additional Information: See the UL Online Certifications Directory at SYSTEMS-PART 1: GENERAL REQUIREMENTS www.u1.com/database for additional information CSA C22.2 NO. 107.1-01, GENERAL USE POWER SUPPLIES IEEE 1547 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Wolf River Electirc Only those products bearing the UL Certification Mark should be considered as being covered by UL's Address:101 Isanti Parkway Certification and Follow-Up Service. IEEE 1547.1 IEEE STANDARD CONFORMANCE TEST PROCEDURES FOR EQUIPMENT NE, Isanti, MN 55040 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Phone number: (763)229-6662 Look for the UL Certification Mark on the product. E-mail: .:ontact(a�wolfriverelectric.com UL 1741. INVERTERS,CONVERTERS,CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY RESOURCES CEC-300-2011-005,-CMF GUIDELINES FOR CALIFORNIA'S SOLAR ELECTRIC INCENTIVE PROGRAMS PURSUANT TO SENATE BILL 1 INVERTER CERTIFICATION ENGINEEw-;ZINC Drawn by.New@engineerinc.io DATE:0911312022 Project Name: &um MNrertlltlt De.cla Nonli Artndcan CerU6cadm Progan &ucv MaMorJrdc Orvcta N.,tU Artroncan C.,pcauar Progam GORDON L WILLIS UL LLC ` UL LLC L Property Adress: ArrylWo—d—anddocvmvnd—llolmg ULMIM s.rvk.sereprowd.donU.IW1 o1 UL LLC(UL) anY—1-1......f U L For µnsbons.Al Airy lMormuion and ­­­i o1—gUL Mak svrwcesa prowd.d onbehWloI UL LLC IULI.mW--..d Y tense.of UL For qu.stlons.plan. 50443rd St NE .oMocla 1-M UL Cu­S—c.R.pr.sontmly.of IJW local UL(.Il.Wrtl.r S. .R.W.s.nt—m IrRp�:uLc dr.ulutloc..— Fridley, MN 55421 Page 1 of 2 Page 2 of 2 roject I scale: PV SYSTEM AS INDICATED Created by UL Document Assembler 2018-07-05 15:07:07-05.00 Created by UL Document Assembler 2018-07-05 15:07:07-05.00 Lp 11 .0 I 101 f I I I N a♦ " Surge Protection RT NUMRER MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Nominal Voltage 0 to 90 VAC 0 to 250 VAC 0 to 300 VDC 0 to 480 VAC 0 to 115 VDC 0 to 600 VDC - MCOV 180V 470V 470V 780V Surge Protection You Can VPRLinetoGround 600V 1200V 1200V 1800V ' Suggested Placement Up to 90VAC circuits, 120/240 VAC circuits Off-grid PV combiners 316V/480VAC circuits Count 4n• 12V,24V,48VDC battery Charge controller inputs Grid-tie PV combiners f circuits up to 300VDC Grid-tie inverter input Non-Isolated Inverters MidNite Solar Surge Protection Devices are type 1 devices, designed for indoor and outdoorType UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 g .4 _ rr - A'.a' applications. Engineered for both AC and PV +� Diagnostic Blue LED MNSPD 300 AC DC electrical systems, the rOVld@ protection LED indicates when voltage is present between Ll +ground and L2+ground Y Y P P MNSPD-115,MNSPD-300-DC and MNSPD-600: to service panels, load centers or electronic LED indicates when voltage is present between Ll +L2(PV+PV-) devices that are directly connected to a MidNite Thermal Disconnector Internal Fuse Surge Protection Device (SPD). Response Time <1 micro sec. I n CONTRACTOR MidNite's SPDs are offered in four models to protect a variety of different voltage ranges. They achieve this protection by clamping surge MNSPD3O0ACFM (Cut-in box) WOL�RIVER voltage to a level that your system can sustain (MNSPD-300-AC included) ELECTRIC without damaging the components of the Performance system. Surge Current Rating per Phase 80kA 03.527" Short Circuit Current Rating 10kA Compare our SPDs against other surge protec- Fusing Individually fused MOVs tion devices. You will see there is no com an- Thermal Fusing Yes P + Over current Fusing Yes Wolf River Electirc son in both our price and features. All our SPDs Operating Frequency 0 to 500 Hz Address:101 Isanti Parkway are made in the USA and have a 5 year warranty. Mechanical Description NE, Isanti, MN 55040 Enclosure Polycarbonate UL94V-0 Phone number: (763)229-6662 Environmental Rating Type4X E-mail: ;ontact(awolfriverelectric.com Connection Method #12 AWG With lightning you only get one Weight 1 lb. Mounting Method 1/2"Conduit Knockout Operating Altitude Sea Level- 12,000'(3,658 Meters) chance, so get the best! 3 82„ 4.425" Storage Temp -401 Fto+185 F(-40°Cto+85°Q SURGE PROTECTION `� Operating Temp -40,F to+185,F(-40°C to+85,C) I IF Diagnostics Blue status LED,one per leg Four Models: Listings and Performance 24"Wires.� I MNSPD-115 UL Standard for Safety,UL 1449 Surge Protective Devices-Fourth Edition ENGINEE�INC CSA C22.2 No.8-M1986 Electromangetic Interference(EMI)Filters,Fourth Edition Drawn by.New@engineerinc.io MNSPD-300-AC DATE:0911312022 MNSPD-300-DC Project Name: MNSPD-600 Model No. Max Operating Surge Current Configuration MCOV SCCR VPR 600V/3kA GORDON L WILLIS r i Voltage per Phase L_G Property Adr— MNSPD-115 100 VAC/1 50VDC 80a I 3-wire 2 Legs) , 180V L-N i 10kA 600V 5044 3rd St NE MNSPD-300-AC 300VAC 80kA 1 3-wire(2 Legs) 470V L-N 10kA 1200V ID�ITC- _ _ I ~ I Fridley, MN 55421 MNSPD-300-DC r 385VDC r 80kA 1,P1,3-wire(2 Legs) t 470V L-N � 10kA 1200V 0kA MNSPD 600 480VAC/600VDC 8 3-wire(2 Legs) 780V L-N 1 OkA 1800V Project scale: www.mldnitesolar.comispd EjI fOIAR me PV SYSTEM AS INDICATED 17722 67th Ave.NE.,Arlington,WA.360-403-7207 FAX:360-691-6862 www.midnitesolar.com/spd 17722-67th Ave NE.Arlington,WA 98223 PH. 360-403-7207 FAX 360-691-6862 D 12.0 WITNESS TEST PROCEDURE GORDON L WILLIS A TEST PROCEDURE THAT WILL BE USED TO VERIFY THE PROTECTION AND OPERATION OF THE SYSTEM SHALL BE SUBMITTED TO XCEL ENERGY FOR APPROVAL.THE PROCEDURE INCLUDES AN ANTI-I SLAN DI NG TEST(FOR ALL SYSTEMS)TO VERIFY THE SYSTEM CEASES GENERATING IN PARALLEL WITH THE XCEL EN ERGY 5044 3rd St N E DISTRIBUTION SYSTEM WHEN THE UTILITY SOURCE IS LOST.EACH SYSTEM IS UNIQUE AND WILL REQUIRE A CUSTOM TEST PROCEDURE BASED ON THE INVERTER Fridley,MN 55421 MANUFACTURER'S RECOMENDATIONS FOR COMISSIONIND AND ANTI-ISLANDING.IN ADDITION TO THE MANUFACTURER'S RECOMENDATIONS. UTILITY:XCEL ENERGY ALLTESTING SHALL BE PERFORMED BY QUALIFIED PERSONELL ONLY PHOTOVOLTAIC PROJECT INFO PV MODULE:(24)HANWHA 40OW STEPS TO VERIFY PV SYSTEM IS READYTO BE ENERGIZED: INVERTER: 1.SITE SECURITY 1-PHASE 120/240 -SITE SHOULD HAVE 24/7 KEYLESS ENTRY AND DRIVABLE ACCESS IF XCEL EQUIPMENT IS PRESENT WITHIN THE SITE FENCE (24) IQ8+MICROINVERTERS 9.6w(DC) -IF APPLICABLE,SITE SHOULD HAVE 24/7 DRIVABLE ACCESS TO ANY XCEL EQUIPMENT INSTALLED OUTSIDE OF THE SITE FENCE THAT IS USED FOR THE SOLE ARRAYI AZIMUT:90(18) PURPOSE OF FEEDING THE PV SYSTEM ARRAY2 AZIMUT:270(4) ARRAYS AZIMUT:270(2) 2.PROPER LABELLING VERIFY LABELING FOR THE MAIN SERVICE PANEL, PV SYSTEM CIRCUIT BREAKER,DC DISCONNECT(WHEN APPLICABLE),UTILITY AC DISCONNECT,PRODUCTION METER AND OTHER RELEVANT LABELLING AND SIGNAGE. ROOF TILT:40,0 3.ENERGIZE THE PV SYSTEM BY CLOSING THE UTILITY DISCONNECT. PLEASE ALLOW 5-MINUTE FOR THE INVERTER TO BOOT-UP. NEC 2020/IRC 2018/IBC 2018 WOLF RIVER ELECTRIC COMPANY 4.WHILE IN NORMAL OPERATION, REFER TO THE REFERENCE POINT OF APPLICABILITY TO VERIFYTHE VOLTAGES AT THE INVERTER AC OUTPUT ARE WITHIN 5%OF THE COMBINED INVERTED AC VOLTAGE RATINGS AND ALL INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE"NORMAL." 101 ISANTI PARKWAY NE#G ISANTI,MN 55040 CONTRACTOR 5.WHILE IN NORMAL OPERATION,VERIFY THAT ALL INVERTERS ARE OPERATIONAL AND PRODUCING POWER.VERIFYTHAT SYSTEM IS GENERATINGAT FULLEST CONTACT@WOLFRIVERELECTRIC.COM REASONABLE CAPACITY.WHILE IN NORMAL OPERATION VERIFY THE VOLTAGES AT THE DER AC TERMINALS ARE WITHIN 5%OF THE COMBINED DER AC VOLTAGE WOLFRIVERELECTRIC.COM RATINGS AND ALL LEDs,ALARMS AND/OR LCD CODES ARE"NORMAL" WOL�RIVER 6.SIMULATE THE LOSS OF UTILITY SOURCE FOR THE ANTI-ISLANDING TEST BY OPENING THE"UTILILITY AC DISCONNECT". ELECTRIC GORDON L WILLIS 7.USING A VOLTMETER,VERIFY THE VOLTAGE AT THE INVERTER SIDE OF THE AC DISCONNECT HAS DROPPED TO ZERO WOLF RIVER SOLAR CASE#05197995 NOTE:ONLY CUSTOMER-OWNED EQUIPMENT SHALL BE USED FOR THIS VERIFICATION. 24/7 UNESCORTED ACCESS SHALL BE Wolf River Electirc 8.USING AN AMMETER OR THE INVERTER'S DISPLAY,VERIFY THE DER OUTPUT OF THE INVERTER HAS CEASED WITHIN TWO SECONDS. PROVIDED FOR THE METERS&AC Address:101 Isanti Parkway DISCONNECT NE, Isanti, MN 55040 9.VERIFY INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE APPROPRIATE FOR LOSS OF UTILITY SOURCE Phone number: (763)229-6662 METERS&UTILITY DISCONNECT WITHIN E-mail:contact(a)_wolfriverelectric.com 10. RESTORE THE LOST UTILITY SOURCE BY CLOSING THE"UTILITY AC DISCONNECT" 10'&LINE OF SIGHT 11.VERIFYTHATTHE INVERTER SYSTEM DELAYS 5 MINUTES BEFORE RESUMING POWER OUTPUT AFTER THE UTILITY SOURCE IS RESTORED UTILITY AC DISCONNECT IS VISIBLE WITNESS TEST LOCKABLE&READILY ACCESSIBLE PROCEDURE 12.VERIFY FIXED POWER FACTOR SETTINGS FOR EACH INVERTER MEETTHE PROJECT REQUIREMENTS GROUND SNOW:50PSF 13. METERTECH HAS VERIFIED METERING EQUIPMENT WIND SPEED:115MPH EXPOSURE CATEGORY:B ENGINEEr-:zINC 14.SYSTEM RESUMED DELIVERY OF POWER NO LESS THAN 5 MINUTES AFTER UTILITY SOURCE IS RESTORED PV ARRAY:2.75 PSF Drawn by.New@engineerinc.io DATE:0911312022 PRODUCTS: Project Name: RAILS:SNAPNRACK GORDON L WILLIS MOUNTS:SNAPN RACK Property Adress: ROOF-MOUNT 5044 3rd St NE Fridley, MN 55421 Project: Scale: PV SYSTEM AS INDICATED F-D 13.0 h MDEPARTMENT OF Y LABOR AND INDUSTRY Wiring Methods and Disconnecting Means ❑ Are the conductor and cable ampacities determined at 125%before adjustment factors?690.8(B) Solar PV Inspection Checklist ❑ How are the PV Source and Output Circuit protected from overcurrent?690.9 ❑ Do AC or DC OCPD's have the appropriate voltage,current and interrupt ratings?690.9 Solar PV Inspection Checklist for REI #ELE- Installer Wolf Rlver Electric Job Address 5044 3rd St NE City/Township Fridley, MN 55421 ❑ Has arc-fault circuit protection been provided for DC source and/or output circuits?690.11 Required Documentation ❑ Is a rapid shutdown required and if so, how is it accomplished and identified?690.12&690.56(C) •Manufacturer's specifications for the inverter Q Is the PV disconnect permanently marked and installed in a readily accessible location?690.13 •Manufacturer's specifications for the module •Manufacturer's specifications for the optimizer(if used) Q Are the Isolating devices or equipment disconnecting means installed in circuits connected to •Verification that the racking system grounding and bonding is listed equipment at a location within the equipment,or within sight and 10 feet of the equipment?(Where PV Inverter the maximum circuit current is greater than 30 amperes an equipment disconnecting means shall be CONTRACTOR provided for isolation.)690.15 ❑ Is the PV system utility-interactive,stand alone or multimode?690.2 Q Has the fuse disconnecting means, if required, been installed?690.15 and 240.40 ❑ Is all the equipment listed for PV application?690.4 ❑ Are PV source or output circuits>30 volts in a raceway or guarded if readily accessible?690.31 WOL�RIVER ❑ Is the system grounded, ungrounded or(functionally grounded)?690.2 and 690.41 ❑ Is single conductor cable used outdoors Type USE-2 or listed &labeled PV wire?690.31 ELECTRIC ❑ Has DC Ground-Fault Protection been provided and properly labeled?690.41(B)? ❑ Are PV source or output circuits on or inside a building in a metal raceway and marked?690.31 ❑ What is the maximum PV system voltage?690.7 ❑ Is all listed equipment rated for the maximum voltage?690.7 Interconnection Wolf River Electirc ❑ Determine the maximum circuit current for the PV Source and Output Circuit; Inverter Output Circuit; Q Has a plaque or directory been installed at each disconnecting means(capable of interconnection) Address:101 Isanti Parkway Inverter Input Circuit; and DC to DC Converter Output(refer to inverter documentation). 690.8 NE, Isanti, MN 55040 denoting all electric power sources&power production sources. 705.10 Phone number: (763)229-6662 ❑ Has the point of connection to other sources been installed per 705.12? E-mail:contact(a_wolfriverelectric.com System Grounding ❑ Is the supply side disconnect readily accessible and within 10'of the connection point?705.11 ❑ Are all exposed non-current carrying metal parts of the PV system grounded?690.43 and 690.47 Q Are the utility interactive inverters connected to the system through a dedicated circuit breaker or PV INSPECTION ❑ Are the mounting structures or systems used for equipment grounding?690.43 fusible disconnecting means?705.12 CHECKLIST ❑ Does the bus or conductor ampacity comply with 705.12? ❑ Are the interconnecting devices used for equipment grounding listed and identified?690.43 ❑ Are the EGC properly sized and protected if exposed and not smaller than#6?690.45,690.46, Q Have all the required labels been applied? (See separate label list.) 690.50, 250.122, 250.120(C) ENGINEEr-:2INC Drawn by.New@engineerinc.io ❑ Has the grounding electrode system been installed?690.47 DATE:0911312022 ❑ If both are present, has the DC grounding electrode system been bonded to the AC GES?690.47(A) Project Name: GORDON L WILLIS Property Adress: 5044 3rd St NE 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.gov Fridley, MN 55421 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.Qov solar-checklist NEC20205olar_Checklist_Checked 20200317 Project: Scale: 1 2 PV SYSTEM AS INDICATED D 14.0 Data Sheet Enphase IQ System Controller 2 Enphase Energy System MODEL NUMBER EP200G,0,-M240US01 Enphase IQ System Controller 2 with neutral-forming transformer IN FT).Microgrid Interconnect Device(MID), breakers,and screws.Streamlinesgrid-in dependent capabll Ries of PV and battery installations. ACCESSORIES and REPLACEMENT PARTS EP200G-NA-XA-E3 Replacement IQ System Controller 2 printed cvcun board EP200G-NA-HD-200A Eaton type BR circuit breaker hold-down screw kit,BRHDK125 CT-200-SPLIT 200 A split core current transformers for Generator metering(+/-2.5%) The Enphase IQ System Controller 2 connects the Circuit breakers(as neededp,' Not included,must order separately. Enphase •BRK-100A-2P-240V Main breaker,2 pole,100A,25kAIC,CSR2100 BRK-20A-2P-240V-8 Circuit breaker,2 pole,20A,101,AIC,BR220B home to grid power,the IQ Battery system,and solar BRK-125A-2P-240V Main breaker,2 pole,125A,25kAIC,CSR2125N BRK-30A-2P-240V Circuit breaker,2 pole,30A,70kAIC,BR230B •BRK-150A-2P-240V:Main breaker,2 poles,50A,251,AIC,CSR2150N •BRK-40A-2P-240V.Circuit breaker,2 pole,40A,10kAIC,BR2408 IQ System Controller 2 PV It provides mlcrogrld Interconnection device BRK-175A-2P-240V:Main breake r,2 pole,175A,25kAIC,CSR2175N BRK-60A-2P-24OV:Circuit breaker,2 pole,60A,10kAIC,BR260 •BRK-20OA-2P-24OV.Main breaker,2 pole.200A,25kAlc,CSR2200N •BRK-80A-2P-24OV.Circuit breaker,2 pole.80A,1 OkAIC,BR280 (MID)functionality by automatically detecting and EP200G-HNDL-Rl IQ System Controller 2 Installation handle kit(order separately) seamlessly transitioning the home energy system EP20OG-LITKIT 10 System Controller 2 literature kit,including labels,feed-through headers,screws,filler plates,and QIG from grid power to backup power in the event of a grid BRK-20A40A-2P-240V 2pole,20A/40A,IOkAIC,BQC220240 ELECTRICAL SPECIFICATIONS failure. It consolidates interconnection equipment into Assembly rating Continuous operation at 100%ofits rating a single enclosure and streamlines grid independent Nominal voltage/range(L-L) 240 VAC/100-310 VAC Voltage measurement accuracy ±1%V nominal(±1.2V L-N and 12.4V L-L) capabilities of PV and storage installations by Auxiliary contact for load control.excess PV control,and generator two-wire control 24 V,IA CONTRACTOR providing a consistent,pre-wired solution for Nominal frequency/range 60 Hz/56-63 Hz residential applications. Frequency measurement accuracy to Hz Maximum continuous current rating 160A Maximum i nput overcurrent protection device 200A Reliable Maximum output overcurrent protection device 200A WO LFR 1 V E R Maximum overcurrent protection device rating for Generator circuit' 80A Durable NEMA type 3R enclosure MaximumoveurentprotectiondeviceratingforstoragebranchcircuR• 80A ELECTRIC m Ten-year limited warranty (the storage branch circuit can be replaced with PV) Maximum overcurrent protection device rating for lQB PV combiner branch circuit- 80A Neutral Forming Transformer(NFT) •Breaker rating(pre-i nstal led)40A between L,and Neutral;40A between 1_2 and Neutral •Continuous rated pourer 3600VA Smart Maximum continuous unbalance current:30A @ 120V •Peak rated power 8800VA for 30 seconds • Controls Safe connectivity to the grid •Peak unbalanced current 80A@ 120Vfor 30 seconds neNPHAse Automatically detects grid outages MECHANICAL DATA Wolf River Electirc Provides seamless transition to backup Dimensions(WZHxD) 50cmx91.6cmx24.6cm(19.7 in x36 in x9.7in) Address:101 Isanti Parkway Weight 39.4kg(87ms) NE, Isanti, MN 55040 Ambient temperature range -40'cto+50"C(-40"Fto 122"F) Phone number: (763)229-6662 Simple Cooling Natural convection,plus heat shield E-mail:contact@wolfriverelectrie.com Connects to the load or service equipment'side of the main Enclosure environmental rating outdoor,NEMAtype 3R,polycarbonate construction load panel Altitude To 2500 meters(8200 feet) Centered mounting brackets support single stud mounting WIRE SIZES Supports conduit entry from the bottom,bottom left side, Connections Main lugsand backuploadlugs Cu/Al IAWG-300KCMIL CONTROLLER 2 and bottom right side (All lugs are rated to 9DC) CSR breaker bottom wrong lugs Cu/AI 2AWG-300 KCMIL •ACcomBit kers iner(lure provided) 1AWG DATA SHEET • Supports whole home and partial home backup and •Accommnerluga,Encnargeluga,andgeneratormga lanwc-2AwG subpanel backup •Neutral(large lugs) Cu/Al;6AWG-300 KCMIL Up to 200A main breaker support Neutral and ground bars Large holes(5/16-24 UNF) 14AWG-t!O AWG Includes neutral-forming transformer for split phase Small holes(10-32UNF) 14AWG-6AWG 120/240V backup operation COMPLIANCE CNGINCCZINC IQ System Controller supports backward compatibility with Compliance UL1741,UL1741 SA,UL1741 PCS,UL1998,UL869A'UL67',UL508',UL50E' older generation of PV microinveners(M215,M250 and S IQSystCSAZ2 System Controller Parl,S,ClaseasSeS00 Equip 6. Drawn by.New@engineerinc.io series),makingrt simple for home owners to upgrade their IQ System Controller2 is apprrrvedfor Use as Service Equipment In the United States'. p pg 2.Compatible with BRHDK125 Hold-Down Kit to comply with 2017 NEC 710.15E for back-fed circuit breakers. DATE:0911312022 systems 3.The IQ System Controller 2 israted22kAIC Easy integration with generator from major manufacturers 4 Notincluded Installer must provide properly rated breaker per circuit breaker list above Project Name: y 9 g ) 5 Sections from these standards were used during the safety evaluation and included in the UL 1741 listing. GORDON L WILLIS 1.IQ System Controller 2 is not suitable for use as service equipment in Canada. Property Adress: To learn more about Enphase offerings,visit enphase.com 5044 3rd St NE To team more about Enphase offerings,visit enohase.com u EN PHAS E ue2021EnphaseEnergy Al rights reserved.Enphase,theEnphaselogo,IQSystemController2,andothernamesarethetrademarksorEnphase �., EN PHAS E Fridley, MN 55421 Energy,Inc Data subject to change.1040-2021 Project: Scale: PV SYSTEM AS INDICATED D 15.0 Data Sheet PRELIMINARY PRELIMINARY Enphase Storage System Enphase Encharge 10 MODELNUMBER ENCHARGE-10-1P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and BMU. Includes: -Three Encharge 3.36kWh base units(B10-A01-US00-1-3) -One Encharge 10 cover kit with cover,mounting bracket,and watertight conduit hubs(B10-C-1050-0) Enphase The Enphase Encharge 10'" battery is reliable, Interconnect kit forwiring between batteries(B10-W-AWG08-0700-0) ACCESSORIES smart,simple,and safe It provides the lowest B10-W-AWG08-0700-0 Connection cable Encharge 10 lifetime energy costs with backup capability for both OUTPUT(AC) @ 240 VAC' new and retrofit solar customers.As an installer,you Rated(continuous)output power' 3.84kVA Peak output power 5.7 kVA(10 seconds) can quickly design the right system size to meet the Nominal voltage/range 240/211 -264 VAC needs of the homeowner. Nominal frequency/range 60/57-61 Hz Rated output current 16 A Power factor(adjustable) 0.85leading...0.85lagging Maximum units per 20 A branch circuit 1 unit(single phase) Interconnection single-phase Round trip efficiency' 89% CONTRACTOR Reliable BATTERY Proven high reliability IQ Series Microinverters Total capacity 10.5 kWh Ten-year limited warranty Usable capacity 10.08 kWh Extensive testing Round trip efficiency 96`� WOL�R1 VER • Maximum DC voltage 73.5V Passive cooling(no moving parts/fans) Ambient operating temperature range -150 C to 550 C(50 F to 1310 F)non-condensing ELECTRIC Optimum operating temperature range 0°C to 300 C(320 F to 860 F) Smart Chemistry Lithium iron phosphate(LFP) Utility TOU optimization MECHANICAL DATA Self consumption Dimensions(WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) Remote upgrade Weight Three each 44.2 kg(97.4 Ibs)base units plus 24.4 kg(53.8 Ibs)cover and mounting bracket;total 156.9 kg(3461bs) Mobile app-based monitoring Enclosure outdoor-46lbs R Wolf River Electirc Encl Grid-forming capability for backup operation cooling Natural convection-No fans NE,Add Isanti, Isanti Parkway Altitude Up to 2500 meters(8200 feet) NE, Isanti, MN 55040 Phone number: (763)229-6662 Simple Mounting Wall mount E-mail: :ontact@wolfriverelectric.com FEATURES AND COMPLIANCE Fully integrated AC battery system Compatibility Compatible with grid-tied PV systems.Compatiblewith Enphase IQ Series Micros,Enphase Quick and easy plug-and-play installation Enpower,and Enphase IQ Envoy for backup operation. Interconnects with standard household AC wiring Communication Wireless 2.4 GHz and 915 MHz Services Backup,self-consumption,TOU,Demand Charge,NEM Integrity BATTERY Monitoring Enlighten Manager and MyEnlighten monitoring options,API integration DATA SHEET Safe Compliance This product will comply with all the required regulatory certifications in the North American markets before launch.Details will be provided in the final data sheet. Cells safety tested LIMITED WARRANTY Lithium iron phosphate(LFP)chemistry for maximum Limited Warranty' >70%capacity,upto 10 years or 4000 cycles safety and longevity ENGI NEEr-4 I NC 1.Supported in backup/off grid operations Drawn by:New@engineerinc.io 2 AC to Battery to AC 3.Whichever occurs first.Restrictions apply. DATE:0911312022 Project Name: GORDON L WILLIS To learn more about Enphase offerings,visit enohase.com PropertyAdre- 5044 3rd St NE Q 2019 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Encharge 10,and other trademarks or service names are theirade- Fridley, M N 55421 EN P H A S E marks of Enphase Energy,Inc Data subject to change n E N P H A S E. To team more about Enphase offerings,visit enphase.COm �./ 2019-11-04 `� Project: Scale: PV SYSTEM AS INDICATED D L _1 5.0 MILBANK IT, ENERGY AT WORK U4801 -XL-5T9 Catalog Number U4801-XL-5T9 Enclosure G90 Galvanized Steel with Powder Coat Finish Marketing Product Description 5 Terminal Ringless Small Closing Plate Lever Bypass Jaw Quantity 5 Terminal 5th Terminal 9 Oclock Position Bypass Type Lever Bypass UPC 784572288218 Number of Meter Positions 1 Position Length(IN) 4.844 CONTRACTOR Equipment Ground Bonded Ground Strap Width(IN) 13 Hub Opening Small Closing Plate Height(IN) Milbank WOLF RIVER Line Side Wire Range 6 AWG-350 kcmil Brand Name Milbank Load Side Wire Range 6 AWG -350 kcmil ELECTRIC Type Ringless Meter Socket Number Of Receptacles 0 Application Meter Socket Standard UL Listed;Type 313 Voltage Rating 600 Volts Alternating Current Wolf River Electirc Amperage Rating 200 Continuous Ampere Address:101 Isanti Parkway NE, Isanti, MN 55040 Phase 1 Phase Phone number: (763)229-6662 E-mail:contact(a_wolfriverelectric.com Frequency Rating 60 Hertz Size 4.844L x 13W x 19H Number Of cutouts 0 MILBANK Cutout Size No Main Breaker DATASHEET Cable Entry Overhead or Underground Terminal Lay in Insulation Glass Polyester CNGINCCIZINC Drawn by:New@engineerinc.io Mounting Surface Mount DATE:0911312022 Project Name: GORDON L WILLIS Property Adress: Please consult serving utility for their requirements prior to ordering or installing,as specifications and approvals vary by utility and may require local t NE 5044 3rd S electrical inspector approval.All installations must be installed by a licensed electrician and must comply with all national and local codes,laws and Fridley, 5 regulations.Milbank reserves the right to make changes in specifications and features shown without notice or obligation 5421 Project 7 Scale: PV SYSTEM j AS INDICATED Milbank Manufacturing 1 4801 D• • D 16.0