HomeMy WebLinkAbout6801 Hickory St Ne Product List Job Details (Continued)
)
Specifications
PowerBrace-Final location of brace(s)is subject to field conditions. Homeowner must have electrical,utilities and/or any obstacles
pulled away from wall. If not done,finished look and effectiveness maybe compromised and may result in the delay of install.
1st Annual Maintenance-Contacted 9-12 Months Post Project to Schedule
American Waterworks will remove drywall/studs as necessary to install the system and is not responsible for drywall replacement.
American Waterworks is not liable in the event the wall is shearing due to lack of visibility.
Tightening Kit Combo-Recommend tightening anchors/Powerraces every 4-6 weeks to torque specifications.American Waterworks is
not responsible if customer over tightens.
Garage floor digout/reverse anchors 4ft wall-Does not include concrete.
Contractor Will
1.)Have public utilities marked in the outside work area.
2.)Remove and replace concrete as necessary in the workplace.
3.)Remove finished walls as necessary.Not responsible for replacement.
4.)Offer a free Radon Charcoal test with design during the initial appointment.
5.)Review contract drawing page and notes with the customer.
Customer Will
1.)Move items at least 7-10 feet away from the work area.American Waterworks is not liable for damages of items left in the work area,
delay in the project may result.
2.)Remove cabinets/shelving.
3.)Remove flooring at least 2 ft from the wall and/or working area,(Carpet 4ft). If not removed,contractor is not responsible for
damages.
4.)Repair any sprinkler lines that may be damaged during the installation.
5.)Mark any private lines that may be hidden underground,and assumes all liability if damage should occur to such lines.
6.)Make sure smoke/CO detectors are up to code(additional cost to the homeowner may occur if not done).
7.)The customer agrees that if work area is not cleared,delays or rescheduling of the project may result.
8.)The customer will be available during the project.
9.)If the customer to-do list is not complete before the project start date,the customer's discount may be void and additional charges
may apply.
10.)By signing,customer understands the expectations of the"Customer Will"section.
Customer Signature: Date:
Product List
Permanently Stabilize Walls
PowerBrace,9' ................................................................................................................................................. 7
AdminFees ..................................................................................................................................................... 1
PowerBrace-Top Bridge Bracket .......................................................................................................................... 7
PBCinch Plate Assemblies .................................................................................................................................. 2
1stAnnual Maintenance ..................................................................................................................................... 1
DrywallRemoval Per Anchor ................................................................................................................................ 6
Tightening Kit Combo,Tightening Kit Combo ........................................................................................................... 1
Geo-Lock Anchors,12"x28"Wall Plate,16"x16"Earth Anchor ............••.............•...................•••.••••...............................• 3
AMERICAN WATERWORKS Job Location Page 3/8
1307 Val leyhigh Dr NW Rochester MN 55901 6801 Hickory St NE Fridley MN 55432-4125 10-10-22(6)
Product List (Continued)
Garage Floor Digout/Reverse Anchors 4ft Wall ......................................................................................................... 3
AMERICAN WATERWORKS Job Location Page 4/8
1307 Valleyhigh Dr NW Rochester MN 55901 6801 Hickory St NE Fridley MN 55432-4125 10-10-22(6)