HomeMy WebLinkAboutImage (8) APPROVED CITY OF EDINA DATE 4801 50" Street West, Edina, MN 55424-1394 Building Inspections Department W/PERMIT NUMBER (952) 826-0372 FAX(952) 826-0389 EdinaMN.gov , ED For office use only. Ventilation, Makeup and Combustion Air Calculations Submittal Form for New Dwellings These blank submittal forms and instructions are available on the City of Edina website. The completed form must be submitted at the time of application for a building and mechanical permit for new construction. Additional forms may be downloaded and printed HERE. Slte Address 01 Contractor Com leted B leaseprint) SI nature Section A Ventilation Quantity (Determine quantity by using Table R403.5.2 or Equation R403.5.2) Square feet(Conditioned area including Basement—finished or unfinished) Total required ventilation Number of bedrooms Continuous ventilation Directions-Determine the total and continuous ventilation rate by either using Table R403.5.2 or equation R403.5.2. The table and equation are below. Table 11403.5.2 Total and Continuous Ventilation Rates(in cfm) Number of Bedrooms 1 2 3 4 5 6 Conditioned space Total/ Total/ Total/ Total/ Total/ Total/ (in sq.ft.) continuous continuous continuous continuous continuous continuous 1000-1500 11 60/40 ❑ 75/40 ❑ 90/45 ❑ 105/53 ❑ 120/60 1:1 135/68 1501-2000 1:1 70/40 11 85/43 ❑ 100/50 ❑ 115/58 11 130/65 ❑ 145/73 2001-2500 ❑ 80/40 11 95/48 ❑ 110/55 ❑ 125/63 ❑ 140/70 11 155/78 2501-3000 ❑ 90/45 ❑ 105/53 ❑ 120/60 1:1 135/68 11 150/75 ❑ 165/83 3001-3500 ❑ 100/50 0 115/58 ❑ 130/65 ❑ 145/73 11 160/80 ❑ 175/88 3501-4000 ❑ 110/55 0 125/63 ❑ 140/70 ❑ 155/78 ❑ 170/85 11 185/93 4001-4500 ❑ 120/60 0 135/68 11 150/75 11 165/83 4 180/90 ❑ 195/98 4501-5000 ❑ 130/65 1:1 145/73 1-1 160/80 ❑ 175/88 ❑ 190/95 ❑ 205/103 5001-5500 ❑ 140/70 ❑ 155/78 13 170/85 11 185/93 1:1 200/100 ❑ 215/108 5501-6000 1:1 150/75 0 165/83 0 180/90 ❑ 195/98 0 210/105 0 225/113 Equation R403.5.2 (0.02 x square feet of conditioned space)+[15 x(number of bedrooms+1)]=Total ventilation rate(cfm) Total ventilation—The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average,for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventilators(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor air intake,or both,for defrost or other equipment cycling. Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided, on a continuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may have automatic cycling controls providing the average flow rate for each hour is met. I:\Building\SafetyPolicieslnformation\EdinaExtrasServer\Docx's\RESIDENTIAL SD05 VENTILATION MAKEUP AND COMBUSTION AIR CALCS.pdf