Loading...
HomeMy WebLinkAboutStephanie Ykema-Stunes PE Letter wStamp 10 13 2022 (1) INEE IN Structural Engineering Letter Date: 10/13/2022 Project Name: Stephanie Ykema-Stunes Project Address: 565 Hugo St NE , Fridley, MN, 55432 Contractor : Wolf River Electric Contractor Address : 101 Isanti ParkwayNE, Isanti, MN 55040 Attn : To Whom It May Concern A Field observation of the condition of the existing framing system was performed by an audit team from Wolf River Electric. From the Field observation of the property, the existing roof structure observed as follows: • Existing roof is supported by 2 x 6 @ 24" rafters at the solar array. The rafters are sloped at approximately 26 degree and have maximum projected horizontal span of 11 feet in between load bearing supports. I HEREBY CERTIFY THAT THIS PLAN, Design Criteria SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED • Applicable codes: 2020 Minnesota Building PROFESSIONAL ENGINEER UNDER THE LAWS Code (2018 IBC)ASCE 7-16 OF THE STAT NESOTA. • Ground Snow Load: 50 psf • Roof Dead Load: 20 psf SIGNATURE: • Wind speed: 125 mph NAME: MANOUCHEHR HAKHA ANESHI • Risk Category: II DATE: LICENSE NUMBER: 58681 Date Certified and Signed: 10/13/2022 I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the Design Criteria. If you have any questions or concerns please contact us, Engineerinc.io, 303 N Glenoaks Blvd Suite 200 Burbank, CA 91502 (747) 333- 5991 new engineerinc.io