Stephanie Ykema-Stunes Solar Drawings (1) wStamps 10 13 2022 (1)
GENERAL NOTES SHEET INDEX SITE MAP & PV LAYOUT PV 1.0 CONTRACTOR 1. All electrical materials shall be new and listed by recognized ELECTRICAL 1-LINE DIAGRAM PV 2.0 I HEREBY CERTIFY THAT THIS PLAN, WOL� RIVE R electrical testing laboratory SYSTEM LABELING DETAIL PV 3.1 SPECIFICATION, OR REPORT WAS PREPARED Address:101 Isanti Parkway Custom made equipment shall have complete test data submitted PLACARD PV 3.2 BY ME OR UNDER MY DIRECT SUPERVISION NE, Isanti, MN 55040 by the manufacturer attesting to its safety PROPERTY PLAN PV 4.0 AND THAT I AM A DULY LICENSED Phone number: (763)229-6662 PROFESSIONAL ENGINEER UNDER THE LAWS E-mail: contact�wolfriverelectric.com ELECTR I C 2. Outdoor equipment shall be NEMA 3R rated or equivalent ATTACHMENT LAYOUT PV 5.1 OF THE STAT NESOTA. 3. All metallic equipment shall be grounded ATTACHMENT DETAIL PV 5.2 Xcel Energy Application#05248701 4. Contractor shall obtain electrical permits prior to installation and INVERTER DATA SHEET D 6.0 SIGNATURE: shall coordinate all inspections, testing commissioning and ENPHASE RAPID SHUTDOWN D 7.0 NAME: MANOUCHEHR HAKH ANESHI Owner: Stephanie Ykema-Stunes acceptance with the client, Property Address: 565 Hugo St NE Fridley, MN 55432 utility co. and city inspectors as needed. MODULE DATA SHEET D 8.0 DATE: LICENSE NUMBER: 58681 p y g 5. The electrical contractor shall verify the exact locations of service RACKING DATA SHEET D 9.0 Property Type: Single Family Residence Date Certified and Drawn by: New@engineerinc.io points and service sizes with the serving utility company and ATTACHMENT DATA SHEET-D 10.0 Date: 1011212022 comply with all utility companies requirements. ENPHASE AC COMBINER BOX Signed: 10/13/2022 6. Drawings are diagrammatic only, routing of raceways shall be D 11.0 option of the contractor unless otherwise noted and shall be INVERTER CERTIFICATION D 12.0 VICINITY MAP (SCALE: NTS) coordinated with other trades. SURGE PROTECTION D 13.0 p 7. If the roof material or the roof structure not adequate for PV WITNESS TEST PROCEDURE D 14.0 installation, call the engineer of record print to installation. The PV INSPECTION CHECKLIST-D 15.0 G contractor is responsible to verify that the roof is capable of s"E withstanding the extra weight. 8. If the distances for cable runs are different than shown, the GOVERNING CODES contractor shall notify the electrical engineer to validate the wire THE INSTALLATION OF SOLAR ARRAYS AND size. Final drawings will be red-lined and updated as appropriate. PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH 9. Whenever a discrepancy in quality of equipment arises on the THE FOLLOWING CODES: drawing or specifications, the contractor shall be responsible for providing and installing all materials and services required by the • 2020 National Electrical Code strictest conditions noted on the drawings or in the specifications • 2018 International Building Code S„E to ensure complete compliance and longevity of the operable • 2018 International Residential Code .Fndley,9M 55 3ZUSA system required by the engineer of record. • 2020 Minnesota Residential Code • 2020 Minnesota Building Code "£ • 2020 Minnesota Energy Code • 2020 Minnesota Accessibility CodeAas • 2020 Minnesota State Fire Code • 2018 International Fire Code • 2018 International Energy Conservation Code PHOTOVOLTAIC NOTES: 2018 Mechanical Code a AS ADOPTED BY THE STATE OF MINNESOTA ALL OTHER ORDINANCE ADOPTED BY THE 1. Rooftop mounted photovoltaic panels and modules shall be tested, LOCAL GOVERNING AGENCIES SATELLITE VIEW (SCALE: NTS) listed and identified by recognized testing laboratory 2. Solar system shall not cover any plumbing or mechanical vents SYST M RATING 3. Modules and support structures shall be grounded unless racking has integrated ground. DC 10.40 KW STC - 4. Removal of an interactive inverter or other equipment shall not AC 7.54 KW STC disconnect the bonding connection between the grounding EQUIPMENT SUMMARY W~ electrode conductor and the photovoltaic source and/or output circuit grounded conductors. r 26 5. All PV modules and associated equipment and wiring shall be protected from physical damage. WITTHH 400 WATT MODULES 1Q8+ MICROINVERTERS 6. Live parts of PV source circuits and PV output circuits over 150v to LECTRICAI NFORMATION ground shall not be accessible to other than qualified persons while energized. NEW 7. Inverter is equipped with integrated DC disconnect, thus providing ground fault protection MAIN SERVICE PANEL BUS SIZE:200A ,t 8. All conductors shall be copper and 75 deg rated MAIN SERVICE BREAKER SIZE:200A 9. A single conductor shall be permitted to be used to perform the MOUNTING SYSTEM: SNAPNRACK CNGI NCCAZI NC multiple functions of do grounding, AC grounding and bonding i i i between AC and DC systems. BUILDING INFORMATION ;`' 10.Non-current carrying metal parts of equipment shall be effectively Engineerinc.io, bonded together. Bond both ends of raceways. CONSTRUCTION TYPE: V-B 303 N lenoaks Blvd L' ew: i OCCUPANCY: R3 Burbank, CA 91502 ROOF:COMP SHINGLE (747) 333- 5991 Truss 2 x 6 @ 24" O.C. new0engineerinc.io N INDEX �Nc 0. SECONDARY INTERCONNECTION MSP.......(N)200A Main Service Panel MM............................ (N) Main Meter ao Total Roof Area: 1265 � � ECB..........(N) Enphase Combiner Box W Q E UAC.........................(N)60A Utility AC a Total Module Area 572 - z7o so JB.............................(N)Junction Box ` 45.21% of Coverage [ .............................(N) Microinverter o a aD ............................Solar Module Q � -- ...................EMT type Conduit 56 ugo St NE. H� S ♦ H Fri y,MN 5543Z USA 1 80° Fire Setback Line SCALE: 3/32" = T-0" ....................FMT type Conduit ,Nr SOLAR MODULES 26 REC 400 Watt 1 Model#REC400AA PURE BLACK INVERTER NOTE:A 36-inchwide pathway INVERTER TYPE: Micro: shall be provided to the emergency 26 Enphase IQ8PLUS escape and rescue opening. ECB Model#IQ8PLUS-72-2-US(240V) *Roof access is not located in areas that �p A UTILITY AC DISCONNECT LOCKABLE require placement of ground ladders over Roof Access `" MM AND READILY ACCESSIBLE exterior wall openings (R324.6.1) EQUIPMENT ELEVATION �� MSP CONTRACTOR 3 a Solar PV Array 1 41e\ O QIn pd10- REC 400 W Modules WOLFRIVER Solar PV Array 2 0 a 10 - IQ8+ Microinverters ELECTRIC � o "0 11- REC 400 W Modules Q p a Pitch: 26 Deg Xcel Energy Application#05248701 a Orientation: 74De From roof 11 - IQ8+ Microinverters b Q a Q �, m � a Main Pitch: 26 Deg ^ s p Meter Utility AC b Q a v S N Main Disconnect Orientation: 254 De fl a Wolf River Electirc Service O ° Q Address:101 Isanti Parkway Panel a NE, Isanti, MN 55040 E 1 oii AEC b Q Q a Phone number: (763)229-6662 E-mail:contact wolfriverelectric.com 10� b 4 b 4 0 b Q b b � Solar PV Array 3 SITE MAP & PV LAYOUT B3 Q ® 3- REC 400 W Modules Note:Keep 3ft clearance from gas meter and AC unit. Solar PV Array 3 r� 3 IQ8+ Microinverters 3- REC 400 W Modules Pitch: 26 Deg St NE Orientation: 164 De ENGINE CZINC 3 - IQ8+ Microinverters NUC�O Drawn by:New@engineerinc.io Pitch: 26 Deg DATE: 1011212022 NOTE: No clearance issue Orientation: 164 De Project Name Distance between all equipments is maximum 10" Stephanie Ykema-Stunes Property Adre— Xcel Energy Application#05248701 565 Hugo St NE Note: 24/ 7 Unescorted keyless access is to be Fridley, MN 55432 provided for ALL UTILITY EQUIPMENT Project: Scale: NOTE: Conduit in attic shall PVSYSTEM AS INDICATED be minimum 18 inches from roof sheating FPV 1 .0 SECONDARY INTERCONNECTION REFERENCE POINT OF APPLICABILITY Note:Keep aft clearance from gas meter and AC unit. 0 ENPHASE Q CABLE (2)#12 AWG PV WIRE ENPHASE AC COMBINER 4 MAIN ETER (1)#6 AWG EGC 120/ 40V, NEW FREE IN THE AIR 120/240V, NEMA 3R PV MONITORING DEVICE 1 ,3W NON CENTER 200A ne e a 1-PHASE MICRO-INVERTER UL1741 2 #14 AWG THWN/THWN-2 Li Sid T MAIN C/B 20A 2-POLE 60A FUSED AC DISCONNECT WITH 40A FUSES 12P-71 .1A UTILITY AC DISCONNECT VISIBLE-OPEN J BOX1 LOCKABLE,READILY ACCESSIBLE - - NEMA3R4 #12 AWG THWN/THWN-2 INSTALL(2)20APV NEMA3R120/240V1P3WIii - ( ) (3)#6AWG THWN/THWN-2 0 0000 2-POLE C/B 0 0000 (1)#12 AWG GND 3/4"EMT 2 FEET z Z) 0 0000 ¢ U00 0000 3/4"EMT 7 FEET00 0000 �� NEW 00 000000 10000 31.46A 31.46A 200A MAIN 3.63A a SERVICE 41 J Box2 �1 PANEL - - - NEMA3R 1 ' ppp 0000 120/240V, x ¢ 000 0000 0000 3 v 1P,3W O � ❑00❑ 0000 0000 z Z) ❑00❑ 0000 0000 Surge Protection ¢ U 0000 0000 0000 0000 0000 ❑oo❑ MNSPD-300-AC NE GE �\ m - 0000 0000 0000 0 U 1 000 2-A000 3�000 (3)#6AWG THWN/THWN-2 - $ 1000 (4)#12 AWG THWN/THWN-2 Add 2nd Ground rod and 9.68A (1)#12 AWG GND (1)#6 AWG GND tie it to the existin round rod. - - 3/4"FMT 20 FEET 3/4"EMT 2 FEET GEC x m 0000 0000 0000 1 #6 AWG GND - (N)GROUNDING U !Z: 0000 0000 0000 In locations where there is no local Public Authority, the customer is exempt from ELECTRODE SYSTEM z Z) 0000 0000 0000 ¢ 0000 0000 0000 inspection, and/or the service has been shut off or disconnected for more than 365 days 1 year), 0000 0000 0000 p y y CONTRACTOR m 1-°i000000 2"'000000 jonrl8�000000 the licensed electrician orwireman shall submit a signed and dated Xcel Energy Electrical 3.63A Inspection Certificate to the Company's Builders Call Line attesting that the electrical installation - - - NEMA3R has been completed and installed according to the current National Electrical Code@, the Xcel m - - - Energy Standard for Electric Installation and Use, and any other applicable codes that apply before WQLRIVER x 0000 0000 0000 U 0000 0000 0000 electric service is energized. z Z) 0000 0000 0000ELECTRIC ¢ U 0000 0000 0000 pp 0000 0000 0000 Xcel EnergyApplication#05248701 NOTE:AC DISCONNECT VISIBLE AND LOCKABLE < 0 m - 0000 0000 0000 U 1�000 2�000 3�000 Note: 24/7 Unescorted keyless access is to be Xcel Energy Application#05248701 2.42A provided for ALL UTILITY EQUIPMENT J BOx4 Design meet National Electric COde(NEC codes) - NEMA3R DC 10.40 KW STC x `0 0000 0000 AC 7.54 KW STC 0000 0000 Wolf River Electirc z Z) 0000 0000 ¢ U 0000 0000 Address:101 Isanti Parkway 0000 0000 m V 00000 00000 santi, MN 55040 1 2 Phone number: (763)229-6662 r il:contact(@_wolfriverelectric.com PV ARRAY RATING WIRE SIZE CALCULATION BRANCH CIRCUIT-A BRANCH CIRCUIT-A Number Modules 13 Type REC400AA REC400Wott Number OF Microinverters in Circuit 13 Number Microinverters 13 Type EnphoselQB+Microinverters IQ8PLUS-72-2-US(240V) Microinverter Maximum Output Current (A) 1.21 ELECTRICAL 1-LINE Total DC Wattage(Watts) Watts STC,(Watts/Module)13*400=5200 Branch Circuit Total Current (A) 13*1.21*1.25=19.66 DIAGRAM Array Currents I-SC 1 10.1 JA I I-MP 1 9.51 JA Breaker Size Per Branch Circuit(A) 20 Module Voltage V-OC 1 48.8 V V-MP 42.1 V BRANCH CIRCUIT-B BRANCH CIRCUIT -B Number Modules 13 Type REC400AA REC400Wott Number OF Microin verters in Circuit 13 26 HANWHA 400 WATT MODULES Number Microinverters 13 Type EnphoselQ8+Microinverters IQ8PLUS-72-2-US(240V) Microinverter Maximum output Current (A) 1.21 CNGINCCI�INC 26 ENPHASE IQ8PLUS MICROINVERTERS ENPHASE IQ8PLUS MICROINVERTERS Total DCWattage(Watts) Watts STC,(Watts/Module)13*400=5200 Branch Circuit Total Current (A) 13*1.21*1.25=19.66 Drawnby.New@engineerinc.io 1 PHASE290VA Array Currents l-SC I 10.1 JA I 1-MP 1 9.51 JA Breaker Size Per Branch Circuit(A) 20 DATE: 1011212022 MAXIMUM OUTPUT CURRENT 1.21A Module Voltage V-OC 1 48.8 1 V V-MP 42.1 V Project Name: AC PORT BACKFEED CURRENT OA FROM JBOX TO ENPHASE COMBINER BOX Stephanie Ykema-Stunes DC SHORT CIRCUIT CURRENT15A Maximum Con tlnius Current(A) 1 19.66 1 More Than 3 CCC Adjist.Factor 0.8 Adjusted ConductorAmpacity(A) 19.66/0.8=24.58 PmpertyAdress: Raceway Height From Roof(Temp 39+22=61C) 3 1/2" #of wire(#BC*2) 4 Ambiend Tern Factor Per NEC Table 310.15(b)(2)(a) 0.71 565 Hugo St NE SYSTEM RATING AND DER POWER OUTPUT DC 10.40 KW STC Temp.Derate Factor(max.continous current divided ambient tem.Factor(A) 24.58*0.71=34.61 Wire Size from NEC Table 310.15(b)16 12 AWG Fridley, MN 55432 AC 7.54 KW STC FROM ENPHASE COMBINER BOX TO MAIN PANEL Project: Scale: INVERTER:ENPHASE IQ8PLUS-72-2-US Total Number Of Microinverters 1 26 1 Total Amps From All Microin verters (A) 26*1.21=31.46 Consider Continuous (A) 31.46*1.25=39.325 PV SYSTEM AS INDICATED INVERTER MAXIMUM CONTINUOUS 7.54 :290VA Temp.Derate Factor(0.91 at wall of the Building)(A) 39.325/0.91=43.21 Wire Size from NEC Table 310.15(b)16 6AWG SYSTEM POWER OUTPUT:26 x 290=7.54 �\, 2.0 .O Ambiend Tem Factor Per NEC Table 310.15(b)(2)(o) 0.91 �/ WARNING NOMINAL OPERATING AC VOLTAGE � NOMINAL OPERATING AC FREQUANCY � TURN OF PHOTOVOLTAIC MAXIMUM AC POWER � AC DISCONNECT PRIOR TO MAXIMUM AC CURRENT � WORKING INSIDE PANEL MAXOCERCURRENTDEVICERATING - FOR AC MODULE PROTECTION PV ARRAY Photovoltaic Power Source DO NOT DISCONNECT PV SYSTEM DC DISCONNECT © LABEL2 UNDER LOAD - OPERATING CURRENT • OPERATING VOLTAGE - CAUTION: SOLAR CIRCUIT MAXIMUM SYSTEM VOLTAGE - MAIN PV SYSTEM SHORT CIRCUIT CURRENT - DISCONNECT © WARNINGLABEL10 LABEL20 © ECTRIC SHOCK HAZARD© MAIN PV SYSTEM RATED MAX POWER-FONT CURRENT � PV SUB-PANEL RATED MAX POWER-FONT VOLTAGE � HE DC CONDUCTORS OF THIS AC DISCONNECT MAXIMUM SYSTEM VOLTAGE PHOTOVOLTAIC SYSTEM ARE SHORT CIRCUIT CURRENT � O UNDE,lei ROUNDAND MAY BE ENERGIZED LABEL11MAX RATED OUTPUT CURRENT OF - THE CHARGE CONTROLLER IF INSTALLED © SOLAR DISCONNECT WARNING © ELECTRIC SHOCK HAZARD CAUTIONSOLAR PV SYSTEM EQUIPPED WITH CONTRACTOR DISCONNECTIF GROUND FAULT IS INDICATED SOLAR ELECTRIC SYSTEM RAPID SHUTDOWN ® NORMALLY GROUNDED CONDUCTORS CONNECTED MAY BE UNDERGROUND AND ENERGIZEDTURN RAPID SHUTDOWN LABEL 13 SWITCH TO THE • POSITION TO • SHUT .• © WARNING-DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM •� HAZARDREDUCE � _ WARNING - • • © ELECTRIC SHOCK HAZARD LABEL 14 CAUTION BielNOT TOUCH =1Ile1 PHOTOVOLTAIC SYSTEM CIRCUIT TERMINALS ON BOTH LINE AND LOAD IS BACKFED Wolf River Electirc SIDES MAY BE ENERGIZED IN THE OPEN '•• - • POSITIONLABEL 15 NE, Isanti, MN 55040 MAIN SERVICE Phone number: PANEL E-mail: � _ _ _ PHOTOVOLTAIC AC DISCONNECT • ® LABEL6MAXIMUM AC OPERATING CURRENT WARNING MAXIMUM AC OPERATINGCURRENT � LABEL 16 SYSTEM LABELING DETAIL LABEL 17 O O © ELECTRIC SHOCK HAZARD© DO NOT TOUCH TERMINALS PHOTOVOLTAIC TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION UTILITY AC DISCONNECT DC VOLTAGE IS ALWAYS PRESENT rawn _ , _ __ WHEN SOLAR MODULESDATE: 1011212022 P.ject Name Stephanie Ykema-Stunes 565 ARE EXPOSED TO SUNLIGHT PHOTOVOLTAIC .. St NE DC DISCONNECTFridley, Note: C 690PVSYSTE:M:]I AS INDICATED CAUTION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: DISCONNECTS LOCATED AS SHOWN: SERVICE 1 OF 2 SERVICE 2 OF 2 ENPHASE COMBINER BOX ENPHASE COMBINER BOX CONTRACTOR PV SYSTEM DISCONNECT PV SYSTEM DISCONNECT FOR UTILITY OPERATION FOR UTILITY OPERATION WOL�RIVER ELECTRIC SERVICE POINT & SERVICE POINT & Xcel Energy Application#05248701 UTILITY METERING UTILITY METERING 0 0 SOLAR PV ARRAY SOLAR PV ARRAY Wolf River Electirc Address:101 Isanti Parkway NE, Isanti, MN 55040 0 0 Phone number: (763)229-6662 E-mail: ;ontact(a_wolfriverelectric.com N N PLACARD W \ � E W E 565 Hugo St NE S 565 Hugo St NE S ENGINEEr-:2INC Drawn Fridley, MN 55432 Fridley, MN 55432 DATE�0112 022gineerinc.io Project Name: Stephanie Ykema-Stunes Property Adre- 565 Hugo St NE Fridley, MN 55432 Project: Scale: PV SYSTEM AS INDICATED PV 3.2 N o° LEGEND Q MSP................ Main Service Panel MM........................ Main Meter D UAC.............Utility AC Disconnect W 0� E ECB..........Enphase Combiner Box 270 aD DD 90, a � Q � 45 10 180° SCALE: 1/16" = T-0" \ CiNG,Nr iI HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED \ BY ME OR UNDER MY DIRECT SUPERVISION Engineerinc.io, AND THAT I AM A DULY LICENSED \ PROFESSIONAL ENGINEER UNDER THE LAWS \\ \ Burbank, CA 9s Blvd OF THE STAT NESOTA. � 40 -2" \ CA 91502 \ (747) 333 -5991 SIGNATURE: EC3 new()engineerinc.io NAME: MANOUCHEHR HAKH ANESHI AC DATE: LICENSE NUMBER: 58681 MM MSP Date Certified and 108'-2" Signed: 10/13/2022 D \ CONTRACTOR DD DD DD D� O \ D WOLF RIVER 108'-2"\ D ELECTRIC D � \ \ Xcel Energy Application#05248701 D I \ \ 6'-1 " D� \ Wolf River Electirc Parkway NE, Isanti, MN 55040 \ v Q> a a o� Phone number: (763)229-6662 E-mail:contact(a)_wolfriverelectric.com o � , c • PROPERTY PLAN PROPERTY LINE/ a \\ •� • • S' • 45'- 0 ENGINEEr-ZINC o•• Sk NE Drawn by.New@engineerinc.io Nu9° DATE: 1011212022 Project Name: Stephanie Ykema-Stunes Property Adre- 565 Hugo St NE Fridley, MN 55432 Project: Scale: Xcel Energy Application#05248701 Pv SYSTEM AS INDICATED Note: 24/ 7 Unescorted keyless access is to be provided for ALL UTILITY EQUIPMENT PV 4.0 MODULES ON ROOF DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Prior to the commencement of work, the contractor shall verify the existing roof and framing Solar Module Modules: Module Weight(Ibs) 48.5 conditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction. 26 #Of Modules 26 Prior to the commencement of work, the contractor shall inspect framing for any damage Attachment Truss 2 x 6 @ 24"O.C. Max Distributed Load: 3 PSF Total Module Weight(Ibs) 1067 such as water damage, cracked framing, etc. and These Plans are stamped for structural Plywood &Building Felt Rack Weight(Ibs) 1261 code compliance of the roof framing supporting the proposed PV installation reference only. Microlnverters Weight(Ibs) 252.2 These plans are not stamped for water leakage. PV modules, racking, and attachment 1 Layer of COMP SHINGLE Total System Weight(Ibs) 2580.2 components must follow manufacturer guidelines and requirements. Attachments to be #Of Standoffs 65 installed in a staggered orientation to properly distribute loads. Max Span Between Standoffs (in) 48 Xcel EnergyApplication#05248701 Loading Per Standoff(Ibs) 39.69 pp Total Area (sq.ft.) 572 Note: 24/7 Unescorted keyless access is to be Loading (PSF) 2.75 provided for ALL UTILITY EQUIPMENT I HEREBY CERTIFY THAT THIS PLAN, J:A' P4GI P41:AF' J:A' ;a I p4C SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS Engineerinc.io, \ OF THE STAT F-� NESOTA. 303 N lenoaks Blvd Burbank, CA 91502 151_61 SIGNATURE: (747) 333- 5991 \ NAME: MANOUCHEHR HAKH ANESHI ATTACHMENT new(a) 13 o 11 DATE: LICENSE NUMBER: 58681 RAIL / Date Certified and — — — — — — — — — — — — — — — — Truss 2 x 6 @ 24" O.C. Signed: 10/13/2022 SNAPNRACK,ULTRA RAIL SPEEDSEAL TM FOOT ' CONTRACTOR / / PARTS LIST 1.86" �1.08"-1.37" ITEM QTI DESCRIPTION WOLF RIVER '0.3811 1 1 SNAPNRACK,SPEEDSEAL FOOT,BASE,SEALING,SILVER/BLACK // / 2 1 BOLT,FLANGE,SERRATED,5/16IN-18 X 2IN,SS / / ELECTRIC 1" 3 1 SNAPNRACK,RL UNIVERSAL,MOUNT SPRING,SS / / 3. 5" 8" 4 1 SNAPNRACK,ULTRA RAIL MOUNT THRU PRC,CLEAR/BLACK / /O / Xcel Energy Application#05248701 1 78" 5 1 SNAPNRACK,ULTRA RAIL MOUNTTAPPED PRC,CLEAR/BLACK �'25" MATERIALS: DIE CAST A380 ALUMINUM,6000 SERIES ALUMINUM,STAINESS STEEL / I DESIGN LOAD(LBS): 802 UP,1333 DOWN,357 SIDE OPTIONS: 2.24" — 3.2D" ULTIMATE LOAD(LBS): 2118 UP,4006 DOWN,1331 SIDE CLEAR/BLACK � / / rc 0.17" 2 58" / / Wolf ss:10River Isar i TORQUE SPECIFICATION: 12 LB-FT ,/ / CERTIFICATION: UL 2703,FILE E359313;WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 / / / NE,Add Isanti, Isanti Parkway NE, Isanti, MN 55040 1.12" WEIGHT 0.45 R // / Phone number: (763)229-6662 1.12 1. 1" R 0.82" \ . \ / ' E-mail:contact@wolfriverelectric.com 5 \ // 1. 9" ATTACHMENT � 3 � \ \ \ LAYOUT -1.50"- 4 \ O \ \ / \ CNGINCGi;ZINC 2 1 / / \ Drawn by:New@engineerinc.io \ DATE: 1011212022 / Project Name: Stephanie Ykema-Stunes / Properly Adre- \ 565 Hugo St NE Fridley, MN 55432 Project: Scale: PV SYSTEM AS INDICATED PV 5. 1 ENGI NEED 1 NC I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION Engineerinc.io, AND THAT I AM A DULY LICENSED 303 N lenoaks Blvd PROFESSIONAL ENGINEER UNDER THE LAWS Burbank, CA 91502 OF THE STAT NESOTA. (747) 333 - 5991 new engineedric.io SIGNATURE: NAME: MANOUCHEHR HAKHA ANESHI DATE: LICENSE NUMBER: 58681 Date Certified and Signed: 10/13/2022 SNAPNRACK UR SPEEDSEAL FOOT FOR MODULE HEIGHT OFF ROOF,RANGE: COMPOSTION ROOF MOUNTING UR-40:3%"-�,4. COMP SHINGLE ROOFING,TVP, REFER TO SNAPNRACK ENGINEERING CHARTS UR-60:4"-5" SNAPNRACK UR SPEEDSEAL FOOT FOR APPLICABLE RAIL SPANS. ROOF DECKING,TYP. SI6`0 S.S. LAG SCREW MUST EMBED A MIN. SNAPNRACK, SNAPNRACK,/h"O S.S. OF 21A" INTO STRUCTURAL MEMBER ULTRA RAIL LAG SCREW,TYP. STRUCUTRAL MEMBER, REFER TO SNAPNRACK INSTALLATION WOOD RAFTER,TYP. MANUAL FOR Y6-0 HARDWARE TORQUE SPECIFICATIONS STRUCTURAL MEMBER SPECIFICATIONS: MINIMUM WOOD GRADE= SPF#2 MINIMUM SPECIFIC GRAVITY= 0.42 ALLOWABLE FASTENER UPLIFT =820 LBS CONTRACTOR ALLOWABLE FASTENER LATERAL= 2SO LBS MINIMUM FASTENER EDGE DISTANCE= 0.5" MINIMUM FASTENER END DISTANCE= 2.2" WOL�RIVER 21!" MIN.EMBEDMENT INTO WOOD MEMBER ELECTRIC Xcel Energy Application#05248701 SNAPNRACK,ULTRA. RAIL MOUNT, TAPPEDi6"WASHER,S.S. (MAY INCLUDE NEOPRENE TYPE GASKET) Wolf River Electirc PENETRATION DETAIL Address:101 Isanti Parkway NE, Isanti, MN 55040 Phone number: (763)229-6662 E-mail: .:ontacta_wolfriverelectric.com SNAPNRACK, ULTRA COIL SPRING FOR 3 "0 BOLT, S.S. RAIL MOUNT,THRU �� OPTIONAL CAVITY IN UR SPEEDSEAL FOOT IS FILLED WITH SEALANT TO ENCAPSULATE AND PROTECT THE ROOF PENETRATION ATTACHMENT 5'6"0-18 X 2"BOLT, FROM MOISTURE DETAIL C SERRATED FLANGE,S.S. SNAPNRACK, SPEEDSEAL FOOT, BASE,SEALING ENGINE-Er-:2 INC EXPLODED Drawn by:New@engineerinc.io DATE: 1011212022 SEALANT Project Name: Stephanie Ykema-Stunes Properly Adress: 2%" 565 Hugo St NE 1 ROOF DECKING; Fridley, MN 55432 L] I Project: Scale: PV SYSTEM AS INDICATED UR-40 RAIL I UR-60 RAIL STRUCTURAL MEMBER(RAFTER)FOR USE WITH SNAPNRACK ULTRA SERIES RAILS - — F_PV 5.2 ,'a ENPHASE amom IQ8 and IQ8+ Microinverters INPUT 1'TA(DCJ 108-60-2-US Commonly used module pairings' W 235-350 235-440 Module compatibility 60-celIA20 half-cell 60-cell/120 half-cell and72-cell/144 half-cell MPPr voltage range V 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC currentz[module[so] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required:AC side protection requires max 20A per branch circuit OUTPUT 1 ,1 Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range' V 240/211-264 CONTRACTOR Max continuous output current A 1.0 1.21 Nominalfrequency Hz 60 IQ8 and IQ8+ Microinverters Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuit" 16 13 WO LFR 1 V E R Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Total harmonic distortion `5% ELECTRIC defined microinverters with split-phase power conversion capability to convert DC Overvoltage class AC port III power to AC power efficiently.The brain of the semiconductor-based microinverter Easyto install is our proprietary application-specific integrated circuit(ASIC)which enablesthe Lightweight and compact with AC portbackfeedcurrent mA 3o XcelEnergyApplication#05248701 microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting 1.0 55nm technology with high speed digital logic and has super-fast response times Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-0.85lagging to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Peak efficiency % 97.5 97.6 energy systems. • Faster installation with simple CEC weighted efficiency 'b 97 97 Wolf River EleCtiCC two-wire cabling Night-time power consumption mW 60 Address:101 Isanti Parkway NE, Isanti, MN 55040 Enphase MECHANICAL DATA `~ High productivity and reliability Phone number: (763)229-6662 Ambient temperature range -400C to•60°C(-40°F to+140°F) E-mail:contact@wolfriverelectric.com Produce power even when the Relative humidity range 4%to 100%(condensing) grid is down t .. -Ty -A DC Connector type MC4 • More than one mil lion Cumulative Dimensions(HxWxD) 212mm(8.3")x175mm(6.9')x30.2mm(1.21 Part of the Enphase Energy System,IOBSeries IQB Series Microinverters redeHnereliability hours Of testing Microinverters integrate with the Enphase10 standards with more than one million Weight 1.08kg(2.38lbs) INVERTER Battery.En phase IQ Gateway,and the Enphase cumulative hours of power-on testing. Class]]double-insulated App monitoring and analysis software. enabling an industry-leading limited warranty enclosure Cooling Natural convection-no fans DATA SHEET of up to 25 years. Approved for wet locations Yes • Optimized for the latest high- powered PV modules Acoustic noise at 1 m <60 dBA Pollution degree PD3 eme CERTIFIED Microgrid-forming Enclosure Class II double-insulated.corrosion resistant polymeric enclosure CNG 1 NCCr-:2 1 NC Complies with the latest Environ.category/UV exposurerating NEMA Type 6/outdoor advanced grid support miti Drawn by.New@engineerinc.io Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as DATE: 1011212022 q Y ry Remote automatic updates for CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 N0.107.1-01 IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements Project Name: Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations,when installed Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conformswith NEC 2014.NEC 2017.and NEC 2020 section connectors. according to manufacturer's instructions. Configurable to support a wide 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems.for AC and DC conductors.when installed accordingto Stephanie Ykema-Stunes range of grid profiles manufacturer's instructions. Property Adress: 565 Hugo St NE ®2021EnphaseEnergy.Allrightsreserved.Enphase,theEnphaselogo,IQ8microinverters. MeetSCARule21(UL1741-SA) (1)NoenforcedDC/AC ratio.Seethe compatibility calculator at httpsJ/Iink.enphase.com/ Fridley, MN 55432 and other names are trademarks of Enphase Energy.Inc.Data subject to change requirements module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to Project: Scale: IQ8SP-DS-0002-01-EN-US-2021-10-19 local requirements to define the number of microinverters per branch in your area. I08SP-DS-0002-01-EN-US-2021-10-19 PV SYSTEM AS INDICATED LC 6.0 • � ENPHASE Install the Enphase IQ8 Series Microinverter To install Enphase IQ8 Series Microinverters,read and follow all warnings and instructions in this guide and in the Enphase IQ8 Series Microinverter Enphase Energy//Rapid Shutdown Installation and Operation Manual at aelnhase-com/stnprt Safety warnings are listed on the back page of this guide. The Enphase Microinverter models listed in this guide do not require grounding electrode conductors(GEC),equipment grounding conductors(EGC),or grounded conductor(neutral).The microinverter has a Class II double-insulated rating,which includes ground fault protection(GFP).To support GFP,use only PV modules equipped with DC cables labeled PV Wire or PV Cable Rapid shutdown is built-in IMPORTANT:Enphase IQ8 Series Microinverters require the IQ Cable.An IQ Gateway is required to monitor performance of the IQ Microinverters.The Q Accessories work only with Enphase IQ8 Series Microinverters. Note:After you log in to your Enphase Installer Platform account from Enphase Installer app,Scan the microinverter QR code and connect to the Enphase IQ Gateway to track the system installation progress. The 2014 edition of the National Electrical Code(NEC 2014)added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. NEC 2014,Section 690.12 applies PREPARATION Enphase Microinverters full meet rapid shutdown requirements in the to PV conductors over 10 feetfrom p y p q A Download the pp and o te Enphase Installer A n it to to ) s: the PV array and requires that the ) p � g D Check that you have these other item e ��.� e new code without the need to install any additional electrical equipment. in to your Enphase Installer Platform account.With this r+,,� ACjunction box. conductors power down to 30 volts t.. �} app,scan the microinverter QR code and connect to x Tools:screwdrivers,wire cutter,voltmeter,torque wrench,sockets, and 240 volt-amperes within the Enphase IQ Gateway to track system installation r�' and wrenches for mounting hardware seconds of rapid shutdown inittiation. progress.To download,go to enphase.com/toolkit or scan the QR code at right. E) Protect your system with lightning and/or surge suppression devices.It is also important to have insurance that protects against lightning and String inverters require work arounds for rapid shutdown B) Referto the foseco /table en-uandcheckPVmle-cQmlectricalcompati electrical surges. bility at:Qpphase.com/en-uc_/suonort/modulezom com/en-us/sur)pr)rt/module-cQmpalbAily. Model DC connector Typical PV module*cell count IF Plan your AC branch circuits to meet the following limits for maximum CONTRACTOR &60 2-US MC 4lockin number of microinverters per branch when protected with a 20-amp Work around. Work around. I Q g type Pair with 60 cell/120-half-cell over-current protection device(OCPD) Specialized Rapid Shutdown String Inverter Installed modules electrical box installed on the on roof,a hostile IQBPLUS-72-2-US MC-4 locking type Pair with 60 cell/120-half-cell,66 Maximum* IQ8 Series Microinverters per AC branch circuit(sin- roof cell,or 72 cell/144-hhalf--cell le- hase roof within 10 feet of array. environment that string g P ' WOLR 1 V E R IQ8A-72-2-US IQ8(240V IQ8+ 240V IQ8M(240V) o live irs are not built ) ( ) IQ8F+240-72-2-US MC-0 locking type Pair with 60 cell/120-half-cell,66 Work around. to live in. IQ8H-208-72-2-US cell,or72 cell/144-half--cell 16 13 11 ELECTRIC Shutoff switch that IS `Enphase IQ8 Series Micrdnverters are compatible with bi-facial PV modules if IQ8A(240V) IQ8H(240V) IQ8H(208V) the temperature adjusted electrical parameters(maximum power,voltage and 11 10 9 easily accessible to first current)ofthemodules,consideri the front side electrical arameters I.e.,Mo Xcel Energy Application#05248701 rt9 P ( Limits may vary.Referto local requirerrents to define the number of responders on the ground. backside gain),are within the allowable microirrverter input parameters range. microinverters per branch in your area. w it C) In addition to the Enphase Microinverters,PV modules and racking, G) Size the AC wire gauge to account for voltage rise.Select the correct you will need these Enphase IQ8 Series Microinverters: wire size based on the distance from the beginning ofthe Enphase IQ Work around. Enphase IQ Gateway(model ENV-IQ-AM 1-240)communications Cable to the breaker in the load center.Design for a voltage rise total Extra conduit in Installation. Residential String Inverter Commercial String Inverter gateway or Enphase IQ Combiner(check enphase.com for models): of less than 2%for these sections.Refer to the Voltage Rise Technical Wolf River Electirc is required to monitor solar production. Brief at ennhase_com/support for more information. Address:101 Isanti Parkway Tie wraps or cable clips(Q-CU P-100) NE, Isanti, MN 55040 Enphase Sealing Caps(Q-SEAL-10):for any unused connectors on Best practice:Center-feed the branch circuit to minimize voltage rise in Phone number: (763)229-6662 the Enphase IQ Cable a fully-populated branch. Enphase Terminator(Q-TERM-10):one needed at the end of each E-mail:contactt_wolfriyerelectric.com Enphase comes standard with rapid shutdown capability AC cable segment Enphase Disconnect Tool(Q-DISC-10) Enphase IQ Cable: ENPHASE RAPID // Cable model Connector PV module Connectors SHUTDOWN All Enphase microln- Enphase microinverters spacing* orientation per box r verters,even those that can safely shut down Q-12-10-240 1.3m Portrait(al 1) 240 Terminator COMPATIBILITY were previously installed, automatjcally,leaving Q-12-17-240 2.0m Landscape(60-and 66-cell) 240 WITH PV inherently meet rapid only low-voltage DC Q-12-20-200 2.3m Landscape(72-ce1I) 200 shutdown requirements, electricity isolated to *Allows for 30cm of cable slack no additional equipment the PV module E CNGINCCIZINC or workarounds needed Enphase IQ Cable Drawn by.New@engineerinc.io AC connector DATE: 1011212022 DC connector 02021 Enphase Energy.All rights reserved. Enphase,the Enphase logo,Enphase IQ8 Project Name: Residential Microinverter Commercial Microinverter R Series micranverters(IQ8,IQ8+,IQ8A,IQ8H Stephanie Ykema-Stunes `Tie wraps or cable clips and IQ8M),Enphase Installer Platform, Property Adren Enphase IQ Gateway,and other trademarks 565 Hugo St NE or service names are the trademarks of Fridley, MN 55432 Enphase En Inc.Data subecttochan e �—Enphase IQ8 Series Microinverter P Energy, 1 9 r1l enphase� (horizontal installation shown,vertical Rev02-10-23-2021 Project: Scale: To learn more,visit enphase.com C�J E N E R G Y installation also allowed). III IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII III�I PV SYSTEM AS INDICATED AC junction box 14"0195-02 D 7.0 REC PRODUCT SPEEIFICATION5 SOLAR5 MOST TRUSTED 5OLAR15 MOST TRUSTED laxl:2s[71.7in.1] got[sssl 460 flat] CERTIFICATIONS IEC 61215:2016,IEC 61730:2016,UL 61730(Pending) ❑ t �--( IS0140012004,ISO 90012015.0H SAS 18 0 01-20 0 7,IEC62941 � I llxl[433] ) ) % C E EO Innfa4 6.Ox02 77 [0.2430.011 S `�WARRANTY a Standard'; RECProTnst ^ ®51 :t InstalledbyarlRECCertified Solar Professional No Yes Yes 1120.2 H •g, ,,V[0.4330.011 System Size _ All 425kW 25-50O1kW Product Warranty(yrs) 20 € 25 25 F: 20.5t0.5- Power Warranty(yrs) 24 25 25 [0.8t0.021 k, 1200 f4721 - Labor Warranty(yrs) 0 25 10 rota PowerinYearl 98% 98% 98% Annual Degradation 0.25% 0.25% 025% 4s11a1 6nx3[z6.axo.u] power in Year 25 92% 92% 92% CONTRACTOR zzs[os1 30[1.21 See w a r r anry doom mts for details.Conditions apply Measurements In mm li.1 GENERALDATA MAXIMUMRATINGS 132half-cutRECheterounctioncelis 5tSubiMC4PV-KET4/KST4,12AWG(4mmI Operational temperature: -40._-185*F(-40_-85*C) Cell type. With lead-freegaplesstechnology Connectors: InaccordmrcewithlEC62852 """"........_................rn,.a......ge:......_.____.__..........................._............. ... 6stringsof22cellsinseries P68onlywhenconnected Maximum system vIta i000V OL F 1 V E R ..............................._..........................................................................._........._..........._._._......_.................................................I........................ Maxim um test Ica d(front); -7000Pa046lbs/sgft)" 013in(32mm)solar glasswith 12AWG(4mm')PVwire,43+471n(ll+12q ...................................__......._....._......_._.._....._........._....._........................... ELECTRIC Glass: Cable- Maximum test load rear: -4000Pat 83.5lbs s ft' anti-reflation surface treatment a¢ordarcewlehEN50618 ( ) ( .... ) ..... ..................................................................._..............................._........................._........._..._..._........................................._..........._..... ..,».............................»....,,.,..,.._,.»..,.........,..»......W....,.,».......».._................ ........... Backsheet: Highly resistant polymer Dimensions: 71.7x40x12in 1821x1016x30mm Maxseries fuse rating: 25A to v P y ) ( ) _..........._...._.........._.._....._..._..._...._...._..._....._.__.._....._..._............. Xcel Energy Application#05248701 ................._...._..._...._...._..........................................................._._........................................_._..._...................................._..__....... _.._ Maxreversecurrent: 25A Frame: Anodized aluminum(black) Weight 45 lbs{20.5 kg) 'See lnstaltatl.n manual for m.untinginstructcm. ........................._............................._............................_._........_.........................................................................._...._........._..__..............»_......_ Design load-Test load/1.5(safe y fee to,) r 3-part. bypass diodes,IP67 rated Junction box: Origin Madein5itlgapore ; Inaccordmcewith I EC62790 `4 REC ALPH(X8 PURE ELECTRICAL DATA Product Code':RECxxxAA Pure Black TEMPERATURE RATINGS' Wolf River Electirc PowerOutPut-P (W) 385 .390 395 .400 405 Nominal Module Operating Temperature: 44°C(±2'C) Address:101 Isanti Parkway .....r>ax......P..._.._......._....................._...._....._....... _.__...._... ................. ............................................................................................._.._..................... Watt Class Sorting-(W) 0/+5 0/+5 0/+5 D/+5 D/«5 TemperaturetoefficientofPM x: -026%/°C p NE, Isanti, MN 55040 ........................................_...................................._....................-._............................._..._........................... .._.............. .._................ ._..............................................................................._.........._....................._ Nominal Power Voltage- 412 41.5 41.8 421 42.4 Temperature coefficient of Vac: -0.24%/"C Phone number: (763)229-6662 BLACK SERIES ___..._._..... _...._ . _._.. .. _.. _....._.._........._...... ._............ ..._............. ................._........_............_..................._..._.._. _....__._. . _ E-mail: ;ontact(a)_wolfriverelectric.com v Nominal Power Current-].(A) 9.35 9.40 9.45 951 956 Temperature coefficient of1.6 0.04%/°C _......-_.........._......................__._....._..._._.............._........._.................. ........._........................... .................. .........._._..._ N in Open Circuit Voltage-V.IV) 48.5 48.6 48.7 48.8 48.9 The temperaturecoefficlents stated are llnearvalues PRODUCT SPECIFICATIONS ..........._._............._.._......_...._._......._._......_.._._.................._._....._....._..........._._.»_........_.........._........._..... .._.............. ....._..._.._4 Short C'vcuitCurrent-Isc(A) 9... 10.03 10.07 10.10 10.14 PowerDensity(W/sqft) 19.3 19.6 19.8 20.1 20.3 LOW LIGHT BEHAVIOUR _..........._._............._.._............__...__.___._.__............._...._................_..._...._....._..._..._.__.........__........ ..._.......... .........._...- MODULE ` Panel Efficiency(%) Z0.8 21.1 21.3 21.6 21.9 TypicallowirradianceperformanceofmoduleatSTG r Power Output-Pwx(Wp) 293 297 3D1 3D5 3D9 , i < DATA SHEET .........»................_.»...»....................»..».»........».........»............................................................»» a[ a' pe(V) 38.8 39.1 39.4 39.7 40.0 o ...... ...................................................._......._............_...........-_....__........ ._._..._...._.._.._.._..._...».....»-__........._»__........._...._......_.__.. f Nominal Power Current-IM.(A) 7.55 759 7.63 7.68 7.72 Z .........................................................._._._........._................................................................._.._.......»_._..........................................__._.............. Open Circuit Voltage-V.IV) 45.7 45-8 45.9 46.0 46.1 _..........._............................................__..................................................................................._.............................................I............................. Short Circuit Current-1JA) 8.07 wo 813 816 8.19EXPERENEE d m Irradanca(YY/m'IW ENGINE Cr-:2INC Values estandardtest rmdtiom(STCalrmass AM15,imadiarxe10.75 W/sgft(1000 W/rrP1 tmperatwe 77'F(25°Cl hasedw aprotLcthn REC spreadwlthatolerance.fP,,,,a,Va&4rz3%vAthlnmewanclass.NmlmlmoduleopemtngterVmhwe(NMOT:airmassAMl5.inadlamx Drawn by:New@engineerine.io 8WW/m�tmperat 68'F(20°Clwtdweed33ft/s(Im/s1'Whemwirdima then mlpmwdam(P„..)at STCabme DATE: 1011212022 d400WP 25 YEAR Founded in 1996.REC Group is an international pioneering solar energy PProroject Name R, : company dedicated to empowering consumers with clean,affordable REC Stephanie Ykema-Stunes WARRANTY - solar power.As Solar's Most Trusted,REC is committed to high quality, wvaw.n.. �.I' a 20.3XFT LEAD-FREE mnovaCwn,and a low carbon footprint in the solar materials and solar P nv Adress: panels it manufactures.Headquartered in Norway with operational ❑a 'p 565 Hugo St NE headquarters in Singapore.REC also has regional hubs in No rthAmerica, ,ta Europe,and Asia-Pacific. tc Fridley, MN 55432 0' Project: Scale: PV SYSTEM AS INDICATED D 8.0 Snap rack- UR-40 SnapNrack Ultra Rail UR-60 A sleek, straightforward rail solution for mounting solar modules .. types. Ultra Rail Solar Mounting Solutions features two rail profiles; , • is a lightweight rail profile suitable • •st geographic Ultra Rail • - •• • rail . . . . .. . . . .. .. . ... :. compatible with all . . . . clamps, . . . of install. The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge CONTRACTOR Unparalleled Wire Management • Open rail channel provides room for running wires resulting in a long-lasting quality install WOL�RIVER • Industry best wire management offering ELECTRIC includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Xcel Energy Application#05248701 Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard Wolf River Electirc Address:101 Isanti Parkway NE, Isanti, MN 55040 • Phone number: (763)229-6662 Industry ' • • • Wire Mounts • • E-mail: ;ontact(a)_wolfriverelectric.com Management Heavy Duty UR-60 Rail • • • • • _ • UR-60 rail profile provides increased span capabilities for high wind speeds and snow Single loads ��� � RACKING • • • • • • • Taller, stronger rail profile includes profile- Clamps : Accessories specific rail splice and end cap DATA SHEET _ compatible • All existing mounts, module clamps, and accessories are retained for the same great both rail profiles install experience CNGINCC�INC Drawn by:New@engineerincJo DATE: 1011212022 • - • • - • • Ultra • Project Name: Stephanie Ykema-Stunes Quality. Inn .ovative Superiorrt Propey Adress: RESOURCES snapnrack.com/resources 565"ugo St NESnapNrack Solar • • Solutions engineered to optimize material _ • Fridley, MN 55432 DESIGN snapnrack.com/configurator Project Scale labor re • and improve overall installationquality and safety. Pv SYSTEM AS INDICATED WHERE TO BUY snapnrack.com/where-to-buy 877-732-2860 • • • • D 9.0 DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: SNAPNRACK, ULTRA RAIL SPEEDSEALTm FOOT mwatkins 5flapHruck" SNAPNRACK, ULTRA RAIL SPEEDSEALTm FOOT mwatkins Sfla NN ack- REVISION: Solar Mounting Solutions REVISION: Solar Mo unting Solutions PART NUMBER(S): PART NUMBER(S): 595 MARKET STREET,29TH FLOOR.SAN FRANCISCO,LA 96105 USA 595 MARKET STREET,29TH FLOOR.SAN FRANLISOO,CA 94105 USA A PHONE(415)500 0900.FAX(415)500.0902 PHONE(415)500b900•FAX(415)5MM2 242-02163, 242-02167 �ENFo.MroKNTHIsoF 9HosoKF9LN� �oaROPR1 .9. N. 242-02163, 242-02167 E .o. �=C""'9�,µo�aoaP. . �.�r 1.37 .30 .38 1.86- 1.08 1.00 v�5a SLOT 3.05 CONTRACTOR 2.78 5 fmpNmck 1.78 .25 WOL�ELECTRIC RIVER L 17 _ Q52.24� -�3.20�- Xcel Energy Application#05248701 2.58 4 3 Wolf River Electirc 0.33 Address:101 Isanti Parkway R1.12 NE, Isanti, MN 55040 Phone number: (763)229-6662 1.21 R•82 E-mail:contacta_wolfriverelectric.com 2 1 ATTACHMENT DATA SHEET PARTS LIST 1.99 ITEM QTY DESCRIPTION 1 1 SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER/ BLACK 2 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SS 11CNGINCCZINC 3 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 4 1 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR/ BLACK Drawn by:New@engineerinc.io 5 1 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR/ BLACK 1.50 I DATE: 10/1212022 � MATERIALS: DIE CAST A380 ALUMINUM, 6000 SERIES ALUMINUM, STAINLESS STEEL Project Name: Stephanie Ykema-Stunes DESIGN LOAD (LBS): 802 UP, 1333 DOWN, 357 SIDE OPTIONS: Property Adfe99: ULTIMATE LOAD (LBS): 2118 UP, 4006 DOWN, 1331 SIDE CLEAR/ BLACK 565 Hugo St NE TORQUE SPECIFICATION: 12 LB-FT Fridley, MN 55432 Project: Scale: CERTIFICATION: UL 2703, FILE E359313; WIND-DRIVEN RAIN TEST FROM SUBJECT UL 2582 PV SYSTE L AS INDICATED WEIGHT(LBS): 0.45 ALL DIMENSIONS IN INCHES FD 10.0 Enphase IQ Combiner 4/4C Data Sheet MODEL NUMBER Enphase Networking IQ Combiner 4(X-IQ-AM1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C1220+/-0.5%)and consumption monitoring(+/-2.5%).Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-I0-AM7-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and consumption monitoring(+/-2.5%).Includes Enphase Mobile Connect cellular modem (CELLMODEM-Ml-06-SP-05),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available In the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. IQ Gateway and integrated LTE-M1 cell ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Q Combiner 4/4 C Ensemble Communications Kt -Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05 with 5-year Sprint data plan for modem(included only with IQ Combiner 4C) COMMS-CELLMODEM-MI-06 Ensemblesites CELLMODEM-M1-06-SP-05 -4GbasedLTE-Ml cellular modem with 5-year Sprint data plan X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-M1-06-AT-05 -4GbasedLTE-Ml cellular modem with 5-year AT&T data plan BreakersX-IQ-AM1-240-4C into a single enclosure and streamlines IQ Circuit Su SCirct ubreaker2poe,BOA,EattonBR210 BR230,BR240,BR250,and BR260 circuit breakers. BRK-15A-2-240V Circuit breaker,2 pole,l5A,Eaton BR215 microinverters and storage installations by BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,l5A,Eaton BR215Bwith hold down kit support providing a consistent, pre-wired solution for BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support residential applications. It offers up to four EPLC-01 Power line carrier(communication bridge pair),quantity-one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C 2 pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) ENPHASE busbar assembly.y XA-ENV-PCBA-3 Replacement IQ Gateway printed circus board(PCB)for Combiner 4/4C X-I Q-NA-HD-125A Hold down kit for Eaton circuit breaker with screws CONTRACTOR ELECTRICAL SPECIFICATIONS Smart Rating Continuous duty Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Hz WOLR I V E R Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125A (CELLMODEM-M1-06-SP-05),included only with IQ Max.continuous current rating 65 A EL E CT R I C Combiner4C Max.continuous current rating liput from PV/storage) 64A Includes solar shield to match Enphase IQ Battery Max.fuse/circuit rating(output) 90 A Xcel Energy Application#05248701 aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) • Flexible networking supports III Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included Ethernet,or cellular Envoy breaker 10A or 1 SA rating GE/Siemens/Eaton Included Optional AC receptacle available for PLC bridge • Provides production metering and consumption Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Wolf River Electirc monitoring Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers Address:101 Isanti Parkway MECHANICAL DATA NE, Isanti, MN 55040 Simple Dimensions(WXHXD) 37.5x49.5x16.8cm(14.75"x19.5"x6.63").Height is21.06^(53.5 cm)with mounting brackets. Phone number: (763)229-6662 Weight 7.5kg 06.5lbs) E-mail: .;ontact(awolfriverelectric.com Centered mounting brackets support single Ambient temperature range -400 C to+460 C(AOO to 1150 F) stud mounting I Cooling Natural convection,plus heat shield Supports bottom,back and side conduit entry ENPHASE Up to four 2-pole branch circuits for 240 VAC Enclosure environmental rating Outdoor,NRTLcerti0ed NEMA type3R polycarbonate construction plug-in breakers(not included) Wire sizes 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors I I AC COMBINER BOX X-IQ-AM1-240-4C 80A total PV or storage branch CrCUtS 60 A breaker branch Input:4 to 1/0 AWG copper conductors g Main lug combined output:10 to 2/OAWG copper conductors DA TAS H E E T I Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Reliable Atitu de To 2000 meters(6,560 feet) Durable NRTL-certified NEMA type 3Renclosure INTERNET CONNECTION OPTIONS Five-year limited warranty integrated Wi-Fi 802.11b/g/n E N G I N E Ew-;Z I NC Two years labor reimbursement program coverage Cellular CELLMODEM-MI-06-SP-05,CELLMODEM-Mt-06-AT-05(4G based LTE-M1 cellular modem).Note that an Enphase included for both the IQ Combiner SKU's Mobile connect cellular modem is required for all Ensemble installations. Drawn by:New@engineerinc io Ethernet Optional,802.3.Cat5E(or Cat 6)UTP Ethernet cable(not included) DATE: 1011212022 UL listed COMPLIANCE Project Name: Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.1071,47 CFR,Part 15,Class B,ICES 003 Stephanie Ykema-Stunes Production metering:ANSI C12.20 accuracy class 0.5(PV production) Property Adress: ULConsumption metering:accuracy class25 565 Hugo St NE XAQ-AM1-24D-4 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 Fridley, MN 55432 LISTED ENPHASE 'n ENPHASE To learn more about Enphase offerings,visit ehas%com 'n To learn more about Enphase offerings,visit enphase.com u Project: Scale: np 02022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of PV SYSTEM AS INDICATED Enphase Energy,Inc Data subject to change.02-142022 LQ 11 .0 CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE Certificate Number 20180530-E341165 Certificate Number 20180530-E341165 Report Reference E341165-20171030 Report Reference E341165-20171030 Issue Date 2018-MAY-30 Issue Date 2018-MAY-30 Issued to: ENPHASE ENERGY INC This is to certify that representative samples of the product as specified on this certificate were tested 1420 N McDowell Blvd according to the current UL requirements. Petaluma CA 94954-6515 Permanently-connected, Grid Support utility Interactive,208V single-phase,240V single phase evaluated for use on a split phase system, distributed resource power system. This is to certify that STATIC INVERTERS, CONVERTERS AND representative samples of ACCESSORIES FOR USE IN INDEPENDENT POWER Models 2-2-U,land IQ7 -72, and IQ7X 96,followed by 2,-5, B,or ACM,followed by US+. Models IQ7PD-72-2-US and IQ7PD-842-US. SYSTEMS, PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT USUCNL—Photovoltaic Rapid Shutdown Equipment. See Addendum Models IQ7-60,IQ7PLUS-72, and IQ7X-96,followed by-2,-5,-B,or-ACM,followed by-US+. Models CONTRACTOR IQ7PD-72-2-US and IQ7PD-84-2-US. Have been investigated by UL in accordance with the +may be followed by additional characters not affecting safety Standard(s) indicated on this Certificate. WOL�RIVER Standard(s)for Safety: ELECTRIC Standard(s)for Safety: See Addendum UL 62109-1,SAFETY OF POWER CONVERTERS FOR USE IN PHOTOVOLTAIC POWER Xcel Energy Application#05248701 Additional Information: See the UL Online Certifications Directory at SYSTEMS-PART 1: GENERAL REQUIREMENTS www.u1.com/database for additional information CSA C22.2 NO. 107.1-01, GENERAL USE POWER SUPPLIES IEEE 1547 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Wolf River Electirc Only those products bearing the UL Certification Mark should be considered as being covered by UL's Address:101 Isanti Parkway Certification and Follow-Up Service. IEEE 1547.1 IEEE STANDARD CONFORMANCE TEST PROCEDURES FOR EQUIPMENT NE, Isanti, MN 55040 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Phone number: (763)229-6662 Look for the UL Certification Mark on the product. E-mail: .:ontact(a�wolfriverelectric.com UL 1741. INVERTERS,CONVERTERS,CONTROLLERS AND INTERCONNECTION SYSTEM EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY RESOURCES CEC-300-2011-005,-CMF GUIDELINES FOR CALIFORNIA'S SOLAR ELECTRIC INCENTIVE PROGRAMS PURSUANT TO SENATE BILL 1 INVERTER CERTIFICATION ENG I NEEv-;Z I NC Drawn by:New@engineerincJo DATE: 1011212022 Project Name: &uo.MMr A,da 0.. Nonh All—C111,61 o1 Plogmo &uc.Mahrorbdc D-1N-11 Aomuc.n C.m6ceu1r Prog.m Stephanie Ykema-Stunes UL LLC ` UL LLC L Property Adress: ArrylMorm wenddocvm.mdlwnvdmgULMlMs.rvk.sereprowd.donU1.foIULLLC(UL)menYmllw�z.dl—m-WULForµnsbons.please =tkl ormumnanddoamm—invdmgULMah..rwc.saeprowdedonb.hnllofUL LLC(UL Iamryeuhoni�dY�ense.MULForqu.sl .pleas. 565HugoStNE consl a locd UL Cuvarwr S.i R.pr.smtmly.at IJW l:d.can'abwld�ocauurs: conlecla bcW UL CUWouwr S.—R.pr.s.I.—.l hnp�:uLc dr.ululloc..— Fridley, MN 55432 Page 1 of 2 Page 2 of 2 Project: scale: PV SYSTEM AS INDICATED Created by UL Document Assembler 2018-07-05 15:07:07-05.00 Created by UL Document Assembler 2018-07-05 15:07:07-05.00 D 12.0 I 101 f I I I N a♦ " Surge Protection RT NUMRER MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Nominal Voltage 0 to 90 VAC 0 to 250 VAC 0 to 300 VDC 0 to 480 VAC 0 to 115 VDC 0 to 600 VDC - MCOV 180V 470V 470V 780V Surge Protection You Can VPRLinetoGround 600V 1200V 1200V 1800V ' Suggested Placement Up to 90VAC circuits, 120/240 VAC circuits Off-grid PV combiners 316V/480VAC circuits Count 4n• 12V,24V,48VDC battery Charge controller inputs Grid-tie PV combiners f circuits up to 30OVDC Grid-tie inverter input Non-Isolated Inverters MidNite Solar Surge Protection Devices are type 1 devices, designed for indoor and outdoorType UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 g .4 _ rr - A'.a' applications. Engineered for both AC and PV +� Diagnostic Blue LED MNSPD 300 AC DC electrical systems, the rOVld@ protection LED indicates when voltage is present between Ll +ground and L2+ground Y Y P P MNSPD-115,MNSPD-300-DC and MNSPD-600: to service panels, load centers or electronic LED indicates when voltage is present between Ll +L2(PV+PV-) devices that are directly connected to a MidNite Thermal Disconnector Internal Fuse Surge Protection Device (SPD). Response Time <1 micro sec. I n CONTRACTOR MidNite's SPDs are offered in four models to protect a variety of different voltage ranges. They achieve this protection by clamping surge MNSPD300ACFM (Cut-in box) WOL�RIVER voltage to a level that your system can sustain (MNSPD-300-AC included) ELECTRIC without damaging the components of the Performance system. Surge Current Rating per Phase 80kA Xcel Energy Application#05248701 03.527" Short Circuit Current Rating 10kA Compare our SPDs against other surge protec- Fusing Individually fused MOVs tion devices. You will see there is no com an- Thermal Fusing Yes P + Over current Fusing Yes Wolf River Electirc son in both our price and features. All our SPDs Operating Frequency 0 to 500 Hz Address:101 Isanti Parkway are made in the USA and have a 5 year warranty. Mechanical Description NE, Isanti, MN 55040 Enclosure Polycarbonate UL94V-0 Phone number: (763)229-6662 Environmental Rating Type4X E-mail: ;ontact(awolfriverelectric.com Connection Method #12 AWG With lightning you only get one Weight 1 lb. Mounting Method 1/2"Conduit Knockout Operating Altitude Sea Level- 12,000'(3,658 Meters) chance, so get the best! 3 82„ 4.425" Storage Temp -401 Fto+185 F(-40°Cto+85°Q SURGE PROTECTION Operating Temp -40,F to+185,F(-40°C to+85,C) Diagnostics Blue status LED,one per leg Four Models: Listings and Performance 24"Wires.AtI MNSPD-115 UL Standard for Safety,UL 1449 Surge Protective Devices-Fourth Edition ENGINEER INC CSA C22.2 No.8-M1986 Electromangetic Interference(EMI)Filters,Fourth Edition Drawn by:New@engineerinc.io MNSPD-300-AC DATE: 1011212022 MNSPD-300-DC Project Name MNSPD-600 Model No. Max Operating Surge Current Configuration MCOV SCCR VPR 60OV/3kA Stephanie Ykema-Stunes r i Voltage per Phase L_G Prope yAdress: MNSPD-115 100 VAC/1 50VDC 80kA 3 wire 2Legs) , 180VL-N �tOkA 600V 565 Hugo St NE MNSPD-300-AC 300VAC 80kA 1 3-wire(2 Legs) 470V L-N 10kA 1200V M rk_ffij� _l _ I Fridley, MN 55432 NSPD-300-DC r 385VDC r 80kAe(2 Legs) t 470V L-N � 10kA 1200VMNSPD-600 480VAC/60OVDC 80kA 1/3-wire(2 Le s) 780V L-N 1 OkA 1800V Projectscalewww.micinitesolar.comispd I PV SYSTEM L AS INDICATED 17722 67th Ave.NE.,Arlington,WA.360-403-7207 FAX:360-691-6862 www.midnitesolar.com/spd 17722-67th Ave NE.Arlington,WA 98223 PH. 360-403-7207 FAX 360-691-6862 D 13.0 WITNESS TEST PROCEDURE Stephanie Ykema-Stunes A TEST PROCEDURE THAT WILL BE USED TO VERIFY THE PROTECTION AN D OPERATION OF THE SYSTEM SHALL BE SUBMITTED TO XCEL ENERGY FOR APPROVAL.THE PROCEDURE INCLUDES AN ANTI-ISLANDING TEST(FOR ALL SYSTEMS)TO VERIFY THE SYSTEM CEASES GENERATING IN PARALLEL WITH THE XCEL ENERGY 565 Hugo St NE DISTRIBUTION SYSTEM WHEN THE UTILITY SOURCE IS LOST.EACH SYSTEM IS UNIQUE AND WILL REQUIRE A CUSTOM TEST PROCEDURE BASED ON THE INVERTER Fridley, MN 55432 MANUFACTURER'S RECOMENDATIONS FOR COMISSIONIND AND ANTI-ISLANDING. IN ADDITION TO THE MANUFACTURER'S RECOMENDATIONS. UTILITY:XCEL ENERGY ALLTESTING SHALL BE PERFORMED BY QUALIFIED PERSON ELL ONLY PHOTOVOLTAIC PROJECT INFO PV MODULE:(26)REC 40OW STEPS TO VERIFY PV SYSTEM IS READY TO BE ENERGIZED: INVERTER: 1.SITE SECURITY 1-PHASE 120/240 -SITE SHOULD HAVE 24/7 KEYLESS ENTRY AND DRIVABLE ACCESS IF XCEL EQUIPMENT IS PRESENT WITHIN THE SITE FENCE (26) IQ8+MICROINVERTERS -IF APPLICABLE,SITE SHOULD HAVE 24/7 DRIVABLE ACCESS TO ANY XCEL EQUIPMENT INSTALLED OUTSIDE OF THE SITE FENCE THAT IS USED FOR THE SOLE 10.40Kw(DC) ARRAY TILT:26 PURPOSE OF FEEDING THE PV SYSTEM ARRAY 1 AZIMUT:74(10) ARRAY 2 AZIMUT:254(11) 2.PROPER LABELLING ARRAY 3 AZIMUTA64(3) VERIFY LABELING FOR THE MAIN SERVICE PANEL,PV SYSTEM CIRCUIT BREAKER, DC DISCONNECT(WHEN APPLICABLE),UTILITY AC DISCONNECT,PRODUCTION METER AN D OTHER RELEVANT LABELLING AND SIGNAGE. ARRAY 4 AZIMUT:164(2) 3.ENERGIZE THE PV SYSTEM BY CLOSING THE UTILITY DISCONNECT. PLEASE ALLOW 5-MINUTE FOR THE INVERTER TO BOOT-UP. NEC 2020/IRC 2018/IBC 2018 WOLF RIVER ELECTRIC COMPANY 4.WHILE IN NORMAL OPERATION,REFER TO THE REFERENCE POINT OF APPLICABILITY TO VERIFY THE VOLTAGES AT THE INVERTER AC OUTPUT ARE WITHIN 5%OF THE COMBINED INVERTED AC VOLTAGE RATINGS AND ALL INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE"NORMAL." 101 ISANTI PARKWAY NE#G ISANTI, MN 55040 CONTRACTOR 5.WHILE IN NORMAL OPERATION,VERIFY THAT ALL INVERTERS ARE OPERATIONAL AND PRODUCING POWER.VERIFY THAT SYSTEM IS GENERATING AT FULLEST CONTACT@WOLFRIVERELECTRIC.COM REASONABLE CAPACITY.WHILE IN NORMAL OPERATION VERIFYTHE VOLTAGES ATTHE DER AC TERMINALS ARE WITHIN 5%OF THE COMBINED DER AC VOLTAGE WOLFRIVERELECTRIC.COM RATINGS AND ALL LEDs,ALARMS AND/OR LCD CODES ARE"NORMAL" WOL�RIVER 6.SIMULATE THE LOSS OF UTILITY SOURCE FOR THE ANTI-ISLANDING TEST BY OPENING THE"UTILILITYAC DISCONNECT". ELECTRIC Stephanie Ykema-Stunes 7.USING A VOLTMETER,VERIFY THE VOLTAGE AT THE INVERTER SIDE OF THE AC DISCONNECT HAS DROPPED TO ZERO WOLF RIVER SOLAR Xcel Energy Application#05248701 CASE#05248701 NOTE:ONLY CUSTOMER-OWNED EQUIPMENT SHALL BE USED FOR THIS VERIFICATION. 24/7 UNESCORTED ACCESS SHALL BE Wolf River Electirc 8.USING AN AMMETER OR THE INVERTER'S DISPLAY,VERIFY THE DER OUTPUT OF THE INVERTER HAS CEASED WITHIN TWO SECONDS. PROVIDED FOR THE METERS&AC Address:101 Isanti Parkway DISCONNECT NE, Isanti, MN 55040 9.VERIFY INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE APPROPRIATE FOR LOSS OF UTILITY SOURCE Phone number: (763)229-6662 METERS&UTILITY DISCONNECT WITHIN E-mail:contact(aD_wolfriverelectric.com 10. RESTORE THE LOST UTILITY SOURCE BY CLOSING THE"UTILITY AC DISCONNECT" 10'&LINE OF SIGHT 11.VERIFYTHATTHE INVERTER SYSTEM DELAYS 5 MINUTES BEFORE RESUMING POWER OUTPUTAFTERTHE UTILITYSOURCE IS RESTORED UTILITYAC DISCONNECT IS VISIBLE WITNESS TEST LOCKABLE&READILY ACCESSIBLE PROCEDURE 12.VERIFY FIXED POWER FACTOR SETTINGS FOR EACH INVERTER MEETTHE PROJECT REQUIREMENTS GROUND SNOW:50PSF 13. METER TECH HAS VERIFIED METERING EQUIPMENT WIND SPEED:115MPH EXPOSURE CATEGORY:B ENGINEEr-:zINC 14.SYSTEM RESUMED DELIVERY OF POWER NO LESS THAN 5 MINUTES AFTER UTILITY SOURCE IS RESTORED PV ARRAY:2.75 PSF Drawn by.New@engineerinc.io DATE: 1011212022 PRODUCTS: Project Name: RAILS:SNAPNRACK Stephanie Ykema-Stunes MOUNTS:SNAPNRACK Property Adress: ROOF-MOUNT 565 Hugo St NE Fridley, MN 55432 Project: Scale: PV SYSTEM AS INDICATED D 14.0 h MDEPARTMENT OF Y LABOR AND INDUSTRY Wiring Methods and Disconnecting Means ❑ Are the conductor and cable ampacities determined at 125%before adjustment factors?690.8(B) Solar PV Inspection Checklist ❑ How are the PV Source and Output Circuit protected from overcurrent?690.9 ❑ Do AC or DC OCPD's have the appropriate voltage,current and interrupt ratings?690.9 Solar PV Inspection Checklist for REI #ELE- Installer Wolf Rlver Electric Job Address 565 Hugo St NE City/Township Fridley, MN 55432 ❑ Has arc-fault circuit protection been provided for DC source and/or output circuits?690.11 Required Documentation ❑ Is a rapid shutdown required and if so, how is it accomplished and identified?690.12&690.56(C) •Manufacturer's specifications for the inverter Q Is the PV disconnect permanently marked and installed in a readily accessible location?690.13 •Manufacturer's specifications for the module •Manufacturer's specifications for the optimizer(if used) Q Are the Isolating devices or equipment disconnecting means installed in circuits connected to •Verification that the racking system grounding and bonding is listed equipment at a location within the equipment,or within sight and 10 feet of the equipment?(Where PV Inverter the maximum circuit current is greater than 30 amperes an equipment disconnecting means shall be CONTRACTOR provided for isolation.)690.15 ❑ Is the PV system utility-interactive,stand alone or multimode?690.2 Q Has the fuse disconnecting means, if required, been installed?690.15 and 240.40 ❑ Is all the equipment listed for PV application?690.4 ❑ Are PV source or output circuits>30 volts in a raceway or guarded if readily accessible?690.31 WOL�RIVER ❑ Is the system grounded, ungrounded or(functionally grounded)?690.2 and 690.41 ❑ Is single conductor cable used outdoors Type USE-2 or listed &labeled PV wire?690.31 ELECTRIC ❑ Has DC Ground-Fault Protection been provided and properly labeled?690.41(B)? ❑ Are PV source or output circuits on or inside a building in a metal raceway and marked?690.31 Xcel Energy Application#05248701 ❑ What is the maximum PV system voltage?690.7 ❑ Is all listed equipment rated for the maximum voltage?690.7 Interconnection Wolf River Electirc ❑ Determine the maximum circuit current for the PV Source and Output Circuit; Inverter Output Circuit; Q Has a plaque or directory been installed at each disconnecting means(capable of interconnection) Address:101 Isanti Parkway Inverter Input Circuit; and DC to DC Converter Output(refer to inverter documentation). 690.8 NE, Isanti, MN 55040 denoting all electric power sources&power production sources. 705.10 Phone number: (763)229-6662 ❑ Has the point of connection to other sources been installed per 705.12? E-mail:contact(a_wolfriverelectric.com System Grounding ❑ Is the supply side disconnect readily accessible and within 10'of the connection point?705.11 ❑ Are all exposed non-current carrying metal parts of the PV system grounded?690.43 and 690.47 Q Are the utility interactive inverters connected to the system through a dedicated circuit breaker or PV INSPECTION ❑ Are the mounting structures or systems used for equipment grounding?690.43 fusible disconnecting means?705.12 CHECKLIST ❑ Does the bus or conductor ampacity comply with 705.12? ❑ Are the interconnecting devices used for equipment grounding listed and identified?690.43 ❑ Are the EGC properly sized and protected if exposed and not smaller than#6?690.45,690.46, Q Have all the required labels been applied? (See separate label list.) 690.50, 250.122, 250.120(C) ENGINEEr-:2INC Drawn by.New@engineerinc.io ❑ Has the grounding electrode system been installed?690.47 DATE: 1011212022 ❑ If both are present, has the DC grounding electrode system been bonded to the AC GES?690.47(A) Project Name: Stephanie Ykema-Stunes Property Adress: 565 Hugo St NE 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.gov Fridley, MN 55432 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.Qov solar-checklist NEC20205olar_Checklist_Checked 20200317 Project: Scale: 1 2 PV SYSTEM AS INDICATED F-D1 5.0