HomeMy WebLinkAboutFinal review 7446 Oakley Street PLEASE VERIFY I-BEAM SPREAD AND HOUSE MEASUREMENTS.
APPROVED SEPARATE PERMITS FOR: ELECT, PLUMB. MECH. PIERS ARE NOT REQUIRED AT
JensenDl 1/29/2022 36" EXTERIOR DOORS WHEN
44'-0"HOME LENGTH "PIER SAVERS" ARE UTILIZED.
T-7"ELECT STUBBED THRU SIDEWALL
24'-8"DRAIN DROP 6'-4"WATER
24'-0"GAS INLET 1 1 -0" 1'-5"
20' - 1'-0"GAS INLET+ Ir
,
o --- -----`C ————— `I- -----0----- WATER � o
5'-6" INLET M S
00 N `�' DRAIN ADDITIONAL F \ B
rn = BELOW FLOOR DRAIN ON DROP BLOCKING SEE o / HALF
rn NOTE 2 BELOW
_ N () SITE PER SP95.03.01 BY OTHERS I LO
UJ 20 Ln * COLUMN LOCATION IS�NSTALL MANUAL Gas line air test
UJ J 3' MATE LINE
o � — --------n------��----�-------- required
= 20": Z 11'-7" 11'-0" 6'-9" 11'-3"
_ N
INT RMEDIATE PIERS
W N O Smoke det ctors in each TYPICAL UNIT SPACING PER INSTALL MANUAL
I-BEAM 4'-3" QUANTITY PER INSTALL MANUAL
rn N sleeping room and on each levelLOCATION DRAIN FOOTER SIZE PER INSTALL MANUAL
of the house, p r R314 -- DROP HALF
20. , ----- -- -- — ----- ----- Provide address
numbers on home
1 4'-0° 4' detection er R315 to the street
23'-4" DRAIN DROP
991/2" 20201RC. 8'-0" 8'-01, 8'-0" 8'-0" 8'-0"
AXLE
SPREAD 2'-O" 2'-O"
2'-0,J
PIER SPACING IS FOR ILLUSTRATION
IMPORTANT:When a home is ordered with an optional 80"frame, the frame will be inset from sidewalls and ONLY.ACTUAL PIER SPACING
mating walls 40". VERIFY measurements before starting foundation design. SHOULD BE DETERMINED USING THE
INSTALLATION MANUAL
1) THE MANUFACTURER ASSUMES NO RESPONSIBILITY FOR ACTUAL 5) IT WILL BE THE RESPONSIBILITY OF THE SITE CONTRACTOR
FOUNDATION DESIGN AND CONSTRUCTION. TO VERIFY THE PROPER LOCATION OF COLUMN SUPPORT
2) ADDITIONAL BLOCKING IS REQUIRED AT EACH SIDE OF EXTERIOR BLOCKING AND TO VERIFY THE PROPER MATING LINE GROWTH PERMANENT FOUNDATIONS:CHECK LOCAL BUILDING CODES AND REGULATIONS
DOORS AND AT EACH SIDE OF SIDEWALL OPENINGS GREATER THAN 4 DIMENSIONS BASED UPON ACTUAL SITE CONDITIONS AND AND CONSULT A REGISTERED PROFESSIONAL OR STRUCTURAL ENGINEER WHEN
FEET IN WIDTH(I.E.,PATIO DOORS,PICTURE WINDOWS,ETC.). REQUIREMENTS(DOUBLE WIDES ONLY). YOU ARE SITING YOUR HOME ON A PERMANENT FOUNDATION(SUCH AS A FULL
3) FOR PIER REQUIREMENTS AT ENDWALL SEE FIGURE 8 IN THE 6) ALLOW 1/2"AT MATING LINE FOR MATE UP GROWTH. BASEMENT,CRAWL SPACE,OR LOAD BEARING PERIMETER FOUNDATION).
INSTALLATION MANUAL. 7) SEE SET-UP AND INSTALLATION MANUAL FOR PERIMETER
4) ALL DWV,PLUMBING,GAS SUPPLY,ETC.,DIMENSIONS ON PRINT BLOCKING REQUIREMENTS.
MAY BE+OR-12". MANUFACTURER DISCLAIMER NOTICE:(THIS PIER PRINT IS FOR HOMES PRODUCED ON OR AFTER JUNE 1ST 2006)
PLEASE READ AND UNDERSTAND THE FOLLOWING INFORMATION.THE MANUFACTURER DOES NOT DO FOUNDATION INSTALLATION OF HOMES.
IT WILL BE THE RESPONSIBILITY OF THE DEALER/SITE CONTRACTOR TO INSURE THAT ALL SITE WORK WILL CORRELATE WITH THE UNIT
MODEL NO. MANUFACTURER DATE: ORDERED.
2448 204 2/1/2019
(C ZJJVLJ L �OO REV: HAVING ENOTICE XPERIENCE,ERI NICE,KNOWLEDGE,ANACTURED HOMES WEIGH SEVERAL TONS.DO NOT ATTEMPT TO D UNDERSTANDING OF ALL INSTALLATION REQUIREMENTS.FAILURE ALL ANY TO MEETOME ON T ESE REQTE WITHOUT
UIREMENTS
EME TS
DRAWING N0. _
MAY RESULT IN SERIOUS INJURY OR DEATH TO AN INEXPERIENCED INSTALLER.INSTALLERS:PLEASE READ AND UNDERSTAND THE SET-UP
2448 204 PB
AND INSTALLATION MANUAL SUPPLIED WITH THE HOME BEFORE ATTEMPTING ANY INSTALLATION OF ANY MANUFACTURED HOME.
Site Address: 7446 Oakley St NE
House
19'
Electric
O
Gas
O
7442 14' 7446 23 7450
24 x 48
15'
Street: Oakley St NE Notes: