HomeMy WebLinkAboutJOEL HOOGHEEM Plans ALL
ENERGY
SOLAR I
COMPANY INFORMATION
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
18" RIDGELINE JOEL HOOGHEEM
SETBACK 1473 WINDEMERE DR NE
FRIDLEY, MN 55421
PO 64481
Panel Type
SILFAB 400
3' ACCESS # of Panels
PATHWAY 24
System Size (kW)
9.60
FLUSH ROOF MOUNT
NOTES:
1. (24)ENPHASE IQ8A
INVERTER(S)
2.ARRAY 1:
22'TILT,207°AZIMUTH
AZIMUTH
N
REVISIONS
LAST: 12/9/22 MG
♦ PROJECT-PAGE TITLE
COVER PAGE
PAGE NUMBER
AO
ALL
DISTANCES ENERGY
SOLAR PANELS - INVERTERS: S MAX
INVERTERS- IQ COMBINER PANEL: 75' MAX
IQ COMBINER PANEL-UTILITY FUSED AC DISCONNECT: 2' COMPANY INFORMATION
UTILITY FUSED AC DISCONNECT-BI-DIRECTIONAL METER: 2'
BI-DIRECTIONAL METER-MAIN ELECTRIC SERVICE: 5' ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
CALL-OUTS: (800) 620-3370
INFO@ALLENERGYSOLAR.COM
1: SOLAR PANELS
2: INVERTERS CLIENT INFORMATION
3: ENPHASE IQ COMBINER PANEL MR JOEL R HOOGHEEM &
4: UTILITY FUSED AC DISCONNECT KAREN L HOOGHEEM
5: BI-DIRECTIONAL METER 1473 WINDEMERE DR NE
6: MAIN ELECTRIC SERVICE FRIDLEY, MN 55421
PO 64481
SYSTEM DETAILS
NOTES:
710, 1.(24)ENPHASE IQ8A
3 INVERTER(S)=8.376kW AC
4 S
2.ARRAY 1:
207'AZIMUTH,22'TILT
18" RIDGELIN E �6 (24)SILFAB 40OW=9.60kW
SETBACK
3' ACCESS
PATH WAY
y7 ACCOUNT: 51-5069235-2
? PREMISE: 302995015
METER: 94627733
Q� AZIMUTH
NOTES: `_ N
1. LOCATION OF SERVICE PANEL AND ELECTRICAL
EQUIPMENT ARE SHOWN. FINAL LOCATION MAY
CHANGE
2. LOCATION OF SERVICE PANEL AND ADDITIONAL
ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE REVISIONS
LAST: 12/9/22 MG
3. PV INTERCONNECTION IS A SECONDARY Q
INTERCONNECTION
4.AC DISCONNECT IN READILY ACCESSIBLE
LOCATION WITHIN 10'OF MAIN SERVICE METER/BI-
DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS
ACCESS TO BE PROVIDED FOR UTILITY AC PROJECT-PAGE TITLE
DISCONNECT&BI-DIRECTIONAL METER.
5. PV EQUIPMENT SHALL BE INSTALLED IN OF LABELS LOCATED ON BI-DIRECTIONAL METER, AC SITE MAP
ACCORDANCE WITH NEC 690 AND POSTED WITH MF DISCONNECT, INVERTER(S), AND APPROPRIATE
APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE
PER NEC 705-10, 690-17, &690-64(b)(5). O
R PERMANENT AND DURABLE PAGE NUMBER
6. CIRCUITS: A'�
'v THERE ARE NO CLEARANCE ISSUES DUE TO
(3)CIRCUIT(S)OF 8(15AMPS EACH) OVERHEAD POWERLINES. Al
SOUTH ELEVATION ALL
SOLAR I
42'9"
COMPANY INFORMATION
38' 4'6" ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
JOELHOOGHEEM
1473 WINDEMERE DR NE
FRIDLEY, MN 55421
PO 64481
N
N M SYSTEM DETAILS
io NOTES:
�o
1. ELEVATIONS MAY
VARY DEPENDING ON
GROUND ELEVATION
BUT ARE DRAWN TO
THE BEST OF OUR
ABILITY
2. 2X4 TRUSS @ 24" OC
— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —
WEST ELEVATION
r3-9„
REVISIONS
LAST: 12/9/22 MG
N
M
N M
N
kD
PROJECT-PAGE TITLE
ELEVATION
DRAWINGS
PAGE NUMBER
A2
ALL
ENERGY
i SOLAR I
COMPANY INFORMATION
18" RIDGELINE ALL ENERGY SOLAR, INC
SPEEDSEAL DECKFOOT SNAP-N-RACK MODULE 2X4 TRUSS @ 24" OC SETBACK 3' ACCESS 1264 ENERGY LANE
PATHWAY ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
I I I I
I I JOELHOOGHEEM
I I I I 1473 WINDEMERE DR NE
FRIDLEY, MN 55421
ARRAY 1 � I - i I PO 64481
I I I
-- - I SYSTEM DETAILS
El
' I
SNAP-N-RACK
I I I I I
MOUNTING HARDWARE:
I I I
I I I I I I I 1. (84)L-FEET
Ll
I I I I I I I I
2. (16)RAIL SPLICES
3. CLAMPS
I I I I I I I
(40)MIDCLAMPS
(16)ENDCLAMPS
I I
4. RAIL LENGTHS:
I
(24)172"RAILS
I I
I I I I I i I
I I I I I I 2X4 TRUSS @ 24"OC
-- -
I
I I I I I I I I TOTAL ROOF SURFACE AREA
I I I I I I I I (PLAN VIEW):2,588 SQ FT
I I I I I I I I
I I I I I I I I TOTAL SOLAR MODULE SURFACE
I I I I I I I I I AREA(PLAN VIEW I:485 SQ FT
SOLAR PANELS COVER 18.7% OF
TOTAL ROOF SURFACE AREA IN
PLAN VIEW
*STRINGING TO BE
DETERMINED ON SITE
REVISIONS
LAST: 12/9/22 MG
(24)SILFAB SIL-400 HC+
MODULES
(24)ENPHASE/Q8A INVERTER(S)
CIRCUITS:
(3)CIRCUIT(S)OF 8 MICROS PROJECT-PAGE TITLE
MAX CIRCUIT 15A 20A RAIL AND
LENGTH (120/240V) BREAKER BREAKER STRINGING
ENPHASE IQ7 12 16 DIAGRAM
ENPHASE IQ7+ 9 13 PAGE NUMBER
ENPHASE IQ7A 8 11 75.311 X 40.811 x 1 .40" A3
ALL
MODULE DETAILS: ENERGY
(24) SILFAB
SIL- 400 HC+ (24)SILFAB
9.60kW SIL-400 HC+ COMPANY INFORMATION
RATED POWER ALL ENERGY SOLAR, INC
AT STC: 40OW 1264 ENERGY LANE
ST PAUL, MN 55108
VMP: 36.05V (800) 620-3370
IMP: 11.10A INFO@ALLENERGYSOLAR.COM
5' MAX VOC: 43.02V CLIENT INFORMATION
ISC: 11.58A MR JOEL R HOOGHEEM &
INVERTER DETAILS: KAREN L HOOGHEEM
1473 WINDEMERE DR NE
ENPHASE IQ8A-72-2-US FRIDLEY, MN 55421
Rating: 349 W PO 64481
CEC Weighted Efficiency: 97 % SYSTEM DETAILS
(24) ENPHASE Max DC Voltage: 58.V V TO UTILITY
DC IQ8A Max AC Output Current: 1.45 A SYSTEM SIZE:9.60kW DC
120/240V MAXIMUM POWER:8.376 kW AC
AC Nominal Voltage Range: OPERATING VOLTAGE:120/240V
(3) CIRCUIT(S) OF 8(15A EA) 240V/ 211-264V (1-Phase) MAXIMUM CURRENT:34.8A
Nominal Frequency: 60 Hz ACCOUNT:51-5069235-2
PREMISE:302995015
METER:94627733
XCEL ENERGY
75' MAX 3/4" EMT: BI-DIRECTIONAL METER
(6) #10 THWN 120/240V, 1-PHASE, 3-WIRE V V \
SEE LABEL(S)4(1) #10 GROUND ON FOLLOWING PAGES NOTES:
1.DESIGN MEETS NEC CODE
AND SHALL BE INSTALLED IN
ACCORDANCE WITH NEC 690
AND POSTED WITH APPLICABLE
2' MAX 1" PVC: WARNINGS, SIGNAGE,AND
(2) #6 THWN PLAQUES PER NEC705-10, 690-
17, &690-64(b) (5)
ENPHASE IQ COMBINER PANEL (1) #6 NEUTRAL 2,
120/240V 125A 1 PHASE 2. SOLAR MODULES,INVERTERS,
PLACARD INDICATING EXISTING AND CORRESPONDING
"NO LOAD TO BE SERVED" ELECTRICAL EQUIPMENT ARE
SEE LABEL(S)16, 18,24 LISTED.
ON FOLLOWING PAGES LINETAP INSIDE MAIN
200A 3.INVERTERS ARE UL 1741
ELECTRICAL PANEL VIA MAIN LISTED
UL-LISTED POLARIS LUGS
4.PV INTERCONNECTION IS A
SECONDARY INTERCONNECTION
2' MAX 3/4" EMT: REVISIONS
LAST: 12/9/22 MG
(2) #8 THWN
(1) #10 NEUTRAL
(1) #10 GROUND 12o/
UTILITY FUSED 200A RATED
BUS
AC DISCONNECT
RPA VISIBLE-OPEN TYPE, LOCKABLE, MAIN
/PoC READILYACCESSIBLE LOAD PANEL SEE LABEL(S) 18 PROJECT-PAGE TITLE
ON FOLLOWING PAGES
ELECTRICAL
LINE DIAGRAM
1 PHASE,60A, 120/240V PAGE NUMBER
SEE LABEL(S) 10, 14, 15, 16,20,35
ON FOLLOWING PAGES A4
*DISTANCES NOT TO SCALE
WARNING : PHLTAICNOTE: LABELS ARE FOR ALLOTOVO
• • • 6 GENERAL REFERENCE. ENERGY
NOT ALL LABELS ARE USED
POWER SOURCE • FOR EVERY INSTALLATION. COMPANY INFORMATION
5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT ALL ENERGY SOLAR, INC
1264 ENERGY LANE
• 7 ST PAUL, MN 55108
10 (800) 620-3370
RAPID SHUTDOWN
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
FORSOLAR PV SYSTEM MR JOEL R HOOGHEEM &
KAREN L HOOGHEEM
1473 WINDEMERE DR NE
FA WARNIC $' FRIDLEY, MN 55421
• • • 13 PO 64481
TRICAL SHOCK HAZARD SYSTEM DETAILS
Aj,,C • r
NOT TOUCH TERMINALS INVERTER(S):N/A
INALS ON BOTH LINE ANDAC DISCONNECT(S):10, 16, 18
A WARNING DUAL POWER SOURCE 14 SIDES MAY BE ENERGIZED UTILITY AC
N THE OPEN POSITION DISCONNECT:10, 14, 15, 16,20,
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
MAIN ELECTRICAL SERVICE:18
BI-DIRECTIONAL METER:41,42
15 PHOTOVOLTAIC AC DISCONNECTIQ COMBINER PANEL:16, 18,24
OPERATINGMAIN7�, t', FOVOLTAIC MAXIMUM AC
• OPERATING AC VOLTAGE:
SYSI"rir-DISCONNECT
17 INTERCONNECTION20
LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
DISCONNECT MOUNTED,AND COMPLY WITH
SWITCH - NEC 690
SOLAR PV SYSTEM EQUIPPED 35
ACCOUNT:51-5069235-2
PRODUCTION
WITH RAPID SHUTDOWN PREMISE:302995015
AWARNING 36 METER:94627733
POWER SOURCE OUTPUT CONNECTION. DO NOT 21
RELOCATE THIS OVERCURRENT DEVICE. REVISIONS
TURN RAPID SHUTDOWN HOUSE
LAST: 12/9/22 MG
SWITCH TO THE CAUTION 37 METER
"OFF" POSITION TO SOLARELECTRIC
PVPANELS PV SYSTEM CIRCUIT BREAKER IS BACKFED
SHUT DOWN PV SYSTEM
41 PROJECT-PAGE TITLE
AND REDUCE CAUTION : SOLAR ELECTRIC LABELS
SHOCK HAZARD
IN THE ARRAY SYSTEM CONNECTED PAGE NUMBER
42 A5
ALL
15 ENERGY
i SOLAR I
EMERGENCY DISCONNECT CAUTION . COMPANY INFORMATION
ALL ENERGY SOLAR, INC
DISCONNECTSERVICE 1264 ENERGY LANE
MULTIPLE SOURCES OF POWER (800) 620-3370. STPAUL, 8
-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
MR JOEL R HOOGHEEM &
KAREN L HOOGHEEM
1473 WINDEMERE DR NE
17 PV COMBINER PANEL FRIDLEY, MN 55421
INTERCONNECTION
PV SERVICE/UTILITY PV DISCONNECT PO 64481
HOUSE SERVICE DISCONNECT SYSTEM DETAILS
DISCONNECT SWITCH (INSIDE GARAGE)
INVERTER(S):N/A
AC DISCONNECT(S):10, 16, 18
UTILITY AC
DISCONNECT:10, 14, 15, 16,20,
VOLTAGEMAXIMUM 22 35
MAXIMUM CIRCUIT CURRENT N MAIN ELECTRICAL SERVICE:18
BI-DIRECTIONAL METER:41,42
IQ COMBINER PANEL:16, 18,24
MAX RATED
• •
THE CHARGE CONTROLLER SOLAR ARRAY
• - •-DC CONVERTER All Energy Solar
www.allenergysolar.com
(800) 620-3370
18
. 24 LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
MOUNTED,AND COMPLY WITH
NEC 690
PVCOMBINER ACCOUNT:51-5069235-2
POWER • PREMISE:302995015
PANELONLYMETER:94627733
NO LOADS PHOTOVOLTAIC
REVISIONS
Operating Voltage : 120/240 LAST: 12/9/22 MG
MaximumMaximum Current : 34. 8 Amps
Power :
• •• • KW
PROJECT-PAGE TITLE
LABELS 2
PAGE NUMBER
43 A6