Loading...
HomeMy WebLinkAboutJOEL HOOGHEEM Plans ALL ENERGY SOLAR I COMPANY INFORMATION ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION 18" RIDGELINE JOEL HOOGHEEM SETBACK 1473 WINDEMERE DR NE FRIDLEY, MN 55421 PO 64481 Panel Type SILFAB 400 3' ACCESS # of Panels PATHWAY 24 System Size (kW) 9.60 FLUSH ROOF MOUNT NOTES: 1. (24)ENPHASE IQ8A INVERTER(S) 2.ARRAY 1: 22'TILT,207°AZIMUTH AZIMUTH N REVISIONS LAST: 12/9/22 MG ♦ PROJECT-PAGE TITLE COVER PAGE PAGE NUMBER AO ALL DISTANCES ENERGY SOLAR PANELS - INVERTERS: S MAX INVERTERS- IQ COMBINER PANEL: 75' MAX IQ COMBINER PANEL-UTILITY FUSED AC DISCONNECT: 2' COMPANY INFORMATION UTILITY FUSED AC DISCONNECT-BI-DIRECTIONAL METER: 2' BI-DIRECTIONAL METER-MAIN ELECTRIC SERVICE: 5' ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 CALL-OUTS: (800) 620-3370 INFO@ALLENERGYSOLAR.COM 1: SOLAR PANELS 2: INVERTERS CLIENT INFORMATION 3: ENPHASE IQ COMBINER PANEL MR JOEL R HOOGHEEM & 4: UTILITY FUSED AC DISCONNECT KAREN L HOOGHEEM 5: BI-DIRECTIONAL METER 1473 WINDEMERE DR NE 6: MAIN ELECTRIC SERVICE FRIDLEY, MN 55421 PO 64481 SYSTEM DETAILS NOTES: 710, 1.(24)ENPHASE IQ8A 3 INVERTER(S)=8.376kW AC 4 S 2.ARRAY 1: 207'AZIMUTH,22'TILT 18" RIDGELIN E �6 (24)SILFAB 40OW=9.60kW SETBACK 3' ACCESS PATH WAY y7 ACCOUNT: 51-5069235-2 ? PREMISE: 302995015 METER: 94627733 Q� AZIMUTH NOTES: `_ N 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE REVISIONS LAST: 12/9/22 MG 3. PV INTERCONNECTION IS A SECONDARY Q INTERCONNECTION 4.AC DISCONNECT IN READILY ACCESSIBLE LOCATION WITHIN 10'OF MAIN SERVICE METER/BI- DIRECTIONAL METER. 24/7 UNESCORTED KEYLESS ACCESS TO BE PROVIDED FOR UTILITY AC PROJECT-PAGE TITLE DISCONNECT&BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN OF LABELS LOCATED ON BI-DIRECTIONAL METER, AC SITE MAP ACCORDANCE WITH NEC 690 AND POSTED WITH MF DISCONNECT, INVERTER(S), AND APPROPRIATE APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES LABELS ON MAIN ELECTRIC SERVICE. ALL LABELS ARE PER NEC 705-10, 690-17, &690-64(b)(5). O R PERMANENT AND DURABLE PAGE NUMBER 6. CIRCUITS: A'� 'v THERE ARE NO CLEARANCE ISSUES DUE TO (3)CIRCUIT(S)OF 8(15AMPS EACH) OVERHEAD POWERLINES. Al SOUTH ELEVATION ALL SOLAR I 42'9" COMPANY INFORMATION 38' 4'6" ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION JOELHOOGHEEM 1473 WINDEMERE DR NE FRIDLEY, MN 55421 PO 64481 N N M SYSTEM DETAILS io NOTES: �o 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2X4 TRUSS @ 24" OC — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — WEST ELEVATION r3-9„ REVISIONS LAST: 12/9/22 MG N M N M N kD PROJECT-PAGE TITLE ELEVATION DRAWINGS PAGE NUMBER A2 ALL ENERGY i SOLAR I COMPANY INFORMATION 18" RIDGELINE ALL ENERGY SOLAR, INC SPEEDSEAL DECKFOOT SNAP-N-RACK MODULE 2X4 TRUSS @ 24" OC SETBACK 3' ACCESS 1264 ENERGY LANE PATHWAY ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION I I I I I I JOELHOOGHEEM I I I I 1473 WINDEMERE DR NE FRIDLEY, MN 55421 ARRAY 1 � I - i I PO 64481 I I I -- - I SYSTEM DETAILS El ' I SNAP-N-RACK I I I I I MOUNTING HARDWARE: I I I I I I I I I I 1. (84)L-FEET Ll I I I I I I I I 2. (16)RAIL SPLICES 3. CLAMPS I I I I I I I (40)MIDCLAMPS (16)ENDCLAMPS I I 4. RAIL LENGTHS: I (24)172"RAILS I I I I I I I i I I I I I I I 2X4 TRUSS @ 24"OC -- - I I I I I I I I I TOTAL ROOF SURFACE AREA I I I I I I I I (PLAN VIEW):2,588 SQ FT I I I I I I I I I I I I I I I I TOTAL SOLAR MODULE SURFACE I I I I I I I I I AREA(PLAN VIEW I:485 SQ FT SOLAR PANELS COVER 18.7% OF TOTAL ROOF SURFACE AREA IN PLAN VIEW *STRINGING TO BE DETERMINED ON SITE REVISIONS LAST: 12/9/22 MG (24)SILFAB SIL-400 HC+ MODULES (24)ENPHASE/Q8A INVERTER(S) CIRCUITS: (3)CIRCUIT(S)OF 8 MICROS PROJECT-PAGE TITLE MAX CIRCUIT 15A 20A RAIL AND LENGTH (120/240V) BREAKER BREAKER STRINGING ENPHASE IQ7 12 16 DIAGRAM ENPHASE IQ7+ 9 13 PAGE NUMBER ENPHASE IQ7A 8 11 75.311 X 40.811 x 1 .40" A3 ALL MODULE DETAILS: ENERGY (24) SILFAB SIL- 400 HC+ (24)SILFAB 9.60kW SIL-400 HC+ COMPANY INFORMATION RATED POWER ALL ENERGY SOLAR, INC AT STC: 40OW 1264 ENERGY LANE ST PAUL, MN 55108 VMP: 36.05V (800) 620-3370 IMP: 11.10A INFO@ALLENERGYSOLAR.COM 5' MAX VOC: 43.02V CLIENT INFORMATION ISC: 11.58A MR JOEL R HOOGHEEM & INVERTER DETAILS: KAREN L HOOGHEEM 1473 WINDEMERE DR NE ENPHASE IQ8A-72-2-US FRIDLEY, MN 55421 Rating: 349 W PO 64481 CEC Weighted Efficiency: 97 % SYSTEM DETAILS (24) ENPHASE Max DC Voltage: 58.V V TO UTILITY DC IQ8A Max AC Output Current: 1.45 A SYSTEM SIZE:9.60kW DC 120/240V MAXIMUM POWER:8.376 kW AC AC Nominal Voltage Range: OPERATING VOLTAGE:120/240V (3) CIRCUIT(S) OF 8(15A EA) 240V/ 211-264V (1-Phase) MAXIMUM CURRENT:34.8A Nominal Frequency: 60 Hz ACCOUNT:51-5069235-2 PREMISE:302995015 METER:94627733 XCEL ENERGY 75' MAX 3/4" EMT: BI-DIRECTIONAL METER (6) #10 THWN 120/240V, 1-PHASE, 3-WIRE V V \ SEE LABEL(S)4(1) #10 GROUND ON FOLLOWING PAGES NOTES: 1.DESIGN MEETS NEC CODE AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE 2' MAX 1" PVC: WARNINGS, SIGNAGE,AND (2) #6 THWN PLAQUES PER NEC705-10, 690- 17, &690-64(b) (5) ENPHASE IQ COMBINER PANEL (1) #6 NEUTRAL 2, 120/240V 125A 1 PHASE 2. SOLAR MODULES,INVERTERS, PLACARD INDICATING EXISTING AND CORRESPONDING "NO LOAD TO BE SERVED" ELECTRICAL EQUIPMENT ARE SEE LABEL(S)16, 18,24 LISTED. ON FOLLOWING PAGES LINETAP INSIDE MAIN 200A 3.INVERTERS ARE UL 1741 ELECTRICAL PANEL VIA MAIN LISTED UL-LISTED POLARIS LUGS 4.PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 2' MAX 3/4" EMT: REVISIONS LAST: 12/9/22 MG (2) #8 THWN (1) #10 NEUTRAL (1) #10 GROUND 12o/ UTILITY FUSED 200A RATED BUS AC DISCONNECT RPA VISIBLE-OPEN TYPE, LOCKABLE, MAIN /PoC READILYACCESSIBLE LOAD PANEL SEE LABEL(S) 18 PROJECT-PAGE TITLE ON FOLLOWING PAGES ELECTRICAL LINE DIAGRAM 1 PHASE,60A, 120/240V PAGE NUMBER SEE LABEL(S) 10, 14, 15, 16,20,35 ON FOLLOWING PAGES A4 *DISTANCES NOT TO SCALE WARNING : PHLTAICNOTE: LABELS ARE FOR ALLOTOVO • • • 6 GENERAL REFERENCE. ENERGY NOT ALL LABELS ARE USED POWER SOURCE • FOR EVERY INSTALLATION. COMPANY INFORMATION 5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT ALL ENERGY SOLAR, INC 1264 ENERGY LANE • 7 ST PAUL, MN 55108 10 (800) 620-3370 RAPID SHUTDOWN INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION FORSOLAR PV SYSTEM MR JOEL R HOOGHEEM & KAREN L HOOGHEEM 1473 WINDEMERE DR NE FA WARNIC $' FRIDLEY, MN 55421 • • • 13 PO 64481 TRICAL SHOCK HAZARD SYSTEM DETAILS Aj,,C • r NOT TOUCH TERMINALS INVERTER(S):N/A INALS ON BOTH LINE ANDAC DISCONNECT(S):10, 16, 18 A WARNING DUAL POWER SOURCE 14 SIDES MAY BE ENERGIZED UTILITY AC N THE OPEN POSITION DISCONNECT:10, 14, 15, 16,20, SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAIN ELECTRICAL SERVICE:18 BI-DIRECTIONAL METER:41,42 15 PHOTOVOLTAIC AC DISCONNECTIQ COMBINER PANEL:16, 18,24 OPERATINGMAIN7�, t', FOVOLTAIC MAXIMUM AC • OPERATING AC VOLTAGE: SYSI"rir-DISCONNECT 17 INTERCONNECTION20 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY DISCONNECT MOUNTED,AND COMPLY WITH SWITCH - NEC 690 SOLAR PV SYSTEM EQUIPPED 35 ACCOUNT:51-5069235-2 PRODUCTION WITH RAPID SHUTDOWN PREMISE:302995015 AWARNING 36 METER:94627733 POWER SOURCE OUTPUT CONNECTION. DO NOT 21 RELOCATE THIS OVERCURRENT DEVICE. REVISIONS TURN RAPID SHUTDOWN HOUSE LAST: 12/9/22 MG SWITCH TO THE CAUTION 37 METER "OFF" POSITION TO SOLARELECTRIC PVPANELS PV SYSTEM CIRCUIT BREAKER IS BACKFED SHUT DOWN PV SYSTEM 41 PROJECT-PAGE TITLE AND REDUCE CAUTION : SOLAR ELECTRIC LABELS SHOCK HAZARD IN THE ARRAY SYSTEM CONNECTED PAGE NUMBER 42 A5 ALL 15 ENERGY i SOLAR I EMERGENCY DISCONNECT CAUTION . COMPANY INFORMATION ALL ENERGY SOLAR, INC DISCONNECTSERVICE 1264 ENERGY LANE MULTIPLE SOURCES OF POWER (800) 620-3370. STPAUL, 8 -3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION MR JOEL R HOOGHEEM & KAREN L HOOGHEEM 1473 WINDEMERE DR NE 17 PV COMBINER PANEL FRIDLEY, MN 55421 INTERCONNECTION PV SERVICE/UTILITY PV DISCONNECT PO 64481 HOUSE SERVICE DISCONNECT SYSTEM DETAILS DISCONNECT SWITCH (INSIDE GARAGE) INVERTER(S):N/A AC DISCONNECT(S):10, 16, 18 UTILITY AC DISCONNECT:10, 14, 15, 16,20, VOLTAGEMAXIMUM 22 35 MAXIMUM CIRCUIT CURRENT N MAIN ELECTRICAL SERVICE:18 BI-DIRECTIONAL METER:41,42 IQ COMBINER PANEL:16, 18,24 MAX RATED • • THE CHARGE CONTROLLER SOLAR ARRAY • - •-DC CONVERTER All Energy Solar www.allenergysolar.com (800) 620-3370 18 . 24 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED,AND COMPLY WITH NEC 690 PVCOMBINER ACCOUNT:51-5069235-2 POWER • PREMISE:302995015 PANELONLYMETER:94627733 NO LOADS PHOTOVOLTAIC REVISIONS Operating Voltage : 120/240 LAST: 12/9/22 MG MaximumMaximum Current : 34. 8 Amps Power : • •• • KW PROJECT-PAGE TITLE LABELS 2 PAGE NUMBER 43 A6