Loading...
HomeMy WebLinkAbout22110100 - Olson Letter WESTSHORE DESIGN ENGINEERS, P.C. WM - 100 GREAT OAKS BLVD. I SUITE 115 ALBANY I NEW YORK 1 12203 To: All Energy Solar 66D Mainline Dr. Westfield, MA Date: December 11, 2022 Ref: 22110100 Subject: Olson Residence 97 Craig Way NE Fridley, MN To Whom It May Concern, The following references the Olson Residence in Fridley, MN: 1. Existing roof framing_ Conventional framing is 2x6 at 16"o.c. with a 10'-6" span (horizontal rafter projection) above structural beams below. This existing structure is capable to support all the loads indicated below for this photovoltaic project. 2. Roof Loading: 4psf dead load (modules plus mounting hardware) 50psf ground snow load 5.7psf roof materials (1.7psf 2x6, 1.5psf sheathing, 2.5psf asphalt shingles) Exposure Category B, 129mph wind (3 sec.) This installation design will be in general conformance to the manufacturer's specifications, and complies with all applicable laws, codes, and ordinances, specifically the International Building Code/IBC & IEBC 2020 chapter 9 and International Residential Code/IRC 2020 including all MN regulations and amendments. The spacing and fastening of the mounting brackets is to have a maximum of 48"o.c. span between mounting brackets, staggered, and secured using 5/16" diameter corrosive resistant steel lag bolts and a 2.5" embed. Thank you. Westshore Design Engineers I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am duly Licensed Professional Engineer under the laws of the state of Minnesota `` � �'S••A ••rjt Signature: o •..• r Name: Nicolas Nitti LICENSED••'•�': Date: 12/11/2022 Li nse Number: 54597 = �: PROFESSIONAL '. ENGINEER = 54597 9 ••EXP.6/30/2024 O 12/11/2022 John Eibert Nicolas Nitti, PE Project Coordinator President WestShore Design Engineers 11 100 Great Oaks Blvd. 11 Suite 115 11 Albany,NY 12203 II 518.313.7153