Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Keith Eliason Solar Drawings wStamp 12.08.2022 (3)
GENERAL NOTES IEET INDEX I HEREBY CERTIFY THAT THIS PLAN, CONTRACTOR 1. All electrical materials shall be new and listed by recognized SITE MAP& PV LAYOUT PV 1.0 SPECIFICATION, OR REPORT WAS PREPARED WOLSffIVER electrical testing laboratory ELECTRICAL 1-LINE DIAGRAM PV 2.0 BY ME OR UNDER MY DIRECT SUPERVISION Address:101 Isanti ParkwayCustom made equipment shall have complete test data submitted AND THAT I AM A DULY LICENSED NE, Isanti, MN 55040 by the manufacturer attesting to its safety PLACARD PV 3.2SYSTEM LABELING DETAIL PV 3.1 PROFESSIONAL ENGINEER UNDER THE LAWS Phone number: (763)229-6662 LECTRIC 2. Outdoor equipment shall be NEMA 3R rated or equivalent PROPERTY PLAN PV 4.0 OF THE STAT NESOTA. E-mail: contact@wolfriverelectric.com 3. All metallic equipment shall be grounded ATTACHMENT LAYOUT PV 5.0 Xcel Energy Application#05304632 4. Contractor shall obtain electrical permits prior to installation and SIGNATURE: INVERTER DATA SHEET D 6.0 shall coordinate all inspections, testing commissioning and NAME: MANOUCHEHR HAKHAWAANESHI Owner: Keith Eliason acceptance with the client, ENPHASE RAPID SHUTDOWN D 7.0 DATE: 06/30/24 LICENSE NUMBER: 58681 Property Address: 4623 NE 2nd St, Fridley, MN 55421 utility co. and city inspectors as needed. MODULE DATA SHEET D 8.0 5. The electrical contractor shall verifythe exact locations of service Property Type: Single Family Residence RACKING DATA SHEET Date Certified and points and service sizes with the serving utility company and D 0.0 Drawn by: New@engineeri 022 ATTACHMENT DATA SHEET D 10.0 Signed: 12/08/2022 Date: 11/16/2022 comply with all utility companies requirements. 6. Drawings are diagrammatic only, routing of raceways shall be ENPHASE AC COMBINER BOX D 11.0 option of the contractor unless otherwise noted and shall be INVERTER CERTIFICATION D 12.0 CNGINCC.ZINC VICINITY MAP (SCALE: NISI coordinated with other trades. SURGE PROTECTION D 13.0 7. If the roof material or the roof structure not adequate for PV WITNESS TEST PROCEDURE D 14.0 Engineerinc.io, 303 PV INSPECTION CHECKLIST-D 15.0 N Glenoaks Blvd B,r installation, call the engineer of record print to installation. The Burbank,CA 91502 contractor is responsible to verify that the roof is capable of (747)333-5991 withstanding the extra weight. newOengineerinc.io 8. If the distances for cable runs are different than shown, the GOVERNING CODES contractor shall notify the electrical engineer to validate the wire THE INSTALLATION OF SOLAR ARRAYS AND size. Final drawings will be red-lined and updated as appropriate. m 9. Whenever a discrepancy in quality of equipment arises on the PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH N drawing or specifications, the contractor shall be responsible for THE FOLLOWING CODES: m providing and installing all materials and services required by the • 2020 National Electrical Code •4623NE nd St SA, strictest conditions noted on the drawings or in the specifications • 2018 International Building Code _ to ensure complete compliance and longevity of the operable • 2018 International Residential Code system required by the engineer of record. • 2020 Minnesota Residential Code • 2020 Minnesota Building Code • 2020 Minnesota Energy Code m • 2020 Minnesota Accessibility Code -- a • 2020 Minnesota State Fire Code = m • 2018 International Fire Code = _ • 2018 International Energy Conservation Code PHOTOVOLTAIC NOTES: • 2018 Mechanical Code _ AS ADOPTED BY THE STATE OF MINNESOTA 1. Rooftop mounted photovoltaic panels and modules shall be tested, ALL OTHER ORDINANCE ADOPTED BY THE listed and identified by recognized testing laboratory LOCAL GOVERNING AGENCIES SATELLITE VIEW (SCALE: NTS) 2. Solar system shall not cover any plumbing or mechanical vents SYSTEM RATING r 3. Modules and support structures shall be grounded unless rackinghas integrated round. DC 6.40 KW STC g g ax 4. Removal of an interactive inverter or other equipment shall not AC 4.64 KW STC disconnect the bonding connection between the grounding electrode conductor and the photovoltaic source and/or output tuuiPMENT SUMMARY circuit grounded conductors. 5. All PV modules and associated equipment and wiring shall be 16 HANWHA 400 WATT MODULES protected from physical damage. WITH IQ8+ MICROINVERTERS 6. Live parts of PV source circuits and PV output circuits over 150v to _ ground shall not be accessible to other than qualified persons ELECTRICAL NFORMATION while energized. 4 EXISTING 7. Inverter is equipped with integrated DC disconnect, thus providing ground fault protection MAIN SERVICE PANEL BUS SIZE:200A 8. All conductors shall be copper and 75 deg rated MAIN SERVICE BREAKER SIZE:200A 1 _ 9. A single conductor shall be permitted to be used to perform the g P P MOUNTING SYSTEM: SNAPNRACK multiple functions of do grounding, AC grounding and bonding between AC and DC systems. BUILDING INFORMATION Y li `` ` ' _ .� 10.Non-current carrying metal parts of equipment shall be effectively - • . bonded together. Bond both ends of raceways. CONSTRUCTION TYPE: V-B " OCCUPANCY: R3 ROOF: METAL ROOF _ * 7- Truss 2 x 4 @ 24" O.C. N INDEX o° SECONDARY INTERCONNECTION MSP (E)200AMain Service Panel MM........................(E) Main Meter Total Roof Area: 1242 D ECB....(N) Enphase Combiner Box z y W U �Q E + NE Znd m � M555421 USA 270 ey. Total Module Area: 352 270 O Q 90° JB.......................(N)Junction Box 28.34% of Coverage [�........................(N) Microinverter o D ..................... Solar Module .............EMT type Conduit m N 180° Fire Setback Line a N SCALE: 3/32" = T-0" Z m m y Z m SO' OR MODULES 16 HANWHA 400 Watt 46th Ave NE 46th Ave NE 46th Ave NE 46th Ave NE 46th Ave NE Model#Q.PEAK DUO BLK ML-G10+ m N INVERTER INVERTER TYPE: Micro: m JB/1 16 Enphase IQ8PLUS MSP Model#IQ8PLUS-72-2-US(240V) Z m 3'fire set ack MM LEC EE] UTILITY AC DISCONNECT LOCKABLE AND READILY ACCESSIBLE CONTRACTOR EQUIPMENT ELEVATION I ❑ a 0 11i a WOLF RIVER JB/2 0 ELECTRIC From roof ❑ a N N 7s O I Xcel Energy Application#05304632 Y ❑ a U N Utility � D ❑ a Utility AC Meter w I Wolf River Electric Window Disconnect b2 w Main O N Address:101 Isanti Parkway 10' Service � ❑ a Solar PV Array 1 y ECB 8 Panel z �I NE, Isanti, MN 55040 b D ❑ a o 12-Hanwha 400 W Modules Phone number: (763)229-6662 12-IQ8+Microinverters 10.. I1 Pitch:30 Deg E-mail:contact(awolfriverelectric.com O ❑ a ° Orientation:90 De 0 Solar PV Array 2 KEI SITE MAP & PV 4-Hanwha 400 W Modules I ❑ a LAYOUT 4-IQ8+Microinverters Pitch:30 Deg Orientation:270 De ZO ED a NOTE: Keep 3ft clearance from 3'fire setback 3'fire setback ENGINEER INC gas meter and AC unit Drawn by:New@engineerincJo DATE. 1111612022 J NOTE: No clearance issue Project Name Distance between all equipments is maximum 10" Keith Eliason Property Address: Xcel Energy Application#05304632 4623 NE 2nd St Note: 24/7 Unescorted keyless access is to be Fridley, MN 55421 provided for ALL UTILITY EQUIPMENT Project F Scale: NOTE: Conduit in attic shall PV SYSTEM AS INDICATED be minimum 18 inches from roof sheating FPV 1 .0 SECONDARY INTERCONNECTION REFERENCE POINT OF APPLICABILITY NOTE: Service Panel does not contain center fed Main Breaker: SYSTEM RATING AND DER POWER OUTPUT DC 6.40 KW STC AC 4.64 KW STC INVERTER:ENPHASE IQ8PLUS-72-2-US MAIN METER INVERTER MAXIMUM CONTINUOUS OUTPUT:290VA 120/24OV, PV MONITORING DEVICE ENPHASE IQ COMBINER4 SYSTEM POWER OUTPUT:16 x 290=4.64 1 P,3W (2)#12 AWG THWN/THWN-2 120/24OV, NEMA 3R 60A FUSED AC DISCONNECT WITH Line Side Ta 1 #12 AWG TH 20A 2-POLE FUSE REDUCERS(SERVICE RATED) WITH 30A FUSES, UTILITY AC DISCONNECT VISIBLE-OPEN ENPHASE Q CABLE INSTALL(2)20A PV I LOCKABLE,READILY ACCESSIBLE (2)#12 AWG PV WI RE 2-POLE C/B 120 N2 MA 1 P 3W (1)#6 AWG EGC (4)#12 AWG THWN/THWN-2 NON CENTER 200A FREE IN THE AIR (1)#12 AWG GND L (3)#6AWG THWN/THWN-2 MAIN C/B 3/4"EMT 25 FEET 3/4"SCH 80 PVC EXISTING 2ooA MAIN 19 1-PHASE MICRO-INVERTER U 19.36A L1741 .36A �� SERVICE 14.52A PANEL J BOX - - = NEMA3R °°° 0000 �1 120 P,3W 1 P,3W + -❑+ x Q 0000 0000 0000 O 00000 0000 0000 z 500000 0000 0000 W v 000000 00000 0000000 Surge Protection m 00000 0000 0000 MNSPD-300-AC (3)#6 AWG THWN/THWN-2 (NEW)GEC ° U TOO 2 000 Z000 (1)#6 AWG GND Add 2nd Ground rod and g 4.84A 3/4"SCH 80 PVC tie it to the existin and rod. 1 #6 AWG GND J BOX 2 NOTE:AC DISCONNECT VISIBLE AND LOCKABLE GEC (E)GROUNDING x 0000 0000 0000 0000 In locations where there is no local Public Authorit the customer is exempt t from ELECTRODE SYSTEM v 0000 0000 0000 0000 Y p z 5 0000 0000 0000 0000 Q C) 0000 0000 0000 0000 inspection, and/or the service has been shut off or disconnected for more than 365 days (1 year), M 00000 000 °°°° °°°° 0000 0000 CONTRACTOR m - 0000 0000 0000 000o the licensed electrician or wireman shall submit a signed ned and dated Xcel Ener Electrical 1-,000 2-,000 3-,000 4-,00o Inspection Certificate to the Company's Builders Call Line attesting that the electrical installation 16 HANWHA 400 WATT MODULES has been completed and installed according to the current National Electrical Code@, the Xcel 16 ENPHASE IQ8PLUS MICROCROIN ERTER RS Energy Standard for Electric Installation and Use, and an other applicable codes that apply before ENPHASE IQ8PLUS MICROINVERTERS 9Y Y pp pp Y WOL�RIVER 1 PHASE 290VA electric service is energized. MAXIMUM OUTPUT CURRENT 1.21A ELECTRIC AC PORT BACKFEED CURRENT OA DC SHORT CIRCUIT CURRENT 15A Xcel Energy Application#05304632 Xcel Energy Application#05304632 Note: 24/7 Unescorted keyless access is to be provided for ALL UTILITY EQUIPMENT Design meet National Electric Code(NEC codes) Wolf River Electric DC 6.40 KW STC Address:101 Isanti Parkway AC 4.64 KW STC PVARRAY RATING WIRE SIZE CALCULATION NE, nti, MN 5 5040 Phonea number: (763)763)229-6662 BRANCH CIRCUIT-A BRANCH CIRCUIT-A E-mail: contact@wolfriverelectric.com Number Modules 12 Type Q.PEAK DUO BLK ML-G10+ Hanwha 400 Watt Number OF Microinverters in Circuit 12 Number Microlnverters 12 Type EnphaselQB+Microinverters IQBPLUS-72-2-US(240V) Microinverter Maximum Output Current (A) 1.21 Total DC Wattage(Watts) Watts STC,(Watts/Module)12*400=4800 Branch Circuit Total Current (A) 12*1.21*1.25=18.15 Array Currents I-SC 1 11.14 JA I l-MP 1 10.77 JA Breaker Size Per Branch Circuit(A) 201 ELECTRICAL 1-LINE Module Voltage V-OC 45.3 V V-MP 37.13 V DIAGRAM BRANCH CIRCUIT-B BRANCH CIRCUIT -B Number Modules 4 Type Q.PEAK DUO BLK ML-G10+ Hanwha 400 Watt Number OF Microinverters in Circuit 4 NumberMicrolnverters 4 Type EnphaselQB+Microinverters IQ8PLUS-72-2-US(240V) Microinverter Maximum Output Current (A) 1.21 Total DC Wattage(Watts) Watts STC,(Watts/Module)4*400=1600 Branch Circuit Total Current (A) 4*1.21*1.25=6.05 CNGINECr:ZINC Array Currents l-SC 1 11.14 JA l-MP 10.77 A Breaker Size Per Branch Circuit(A) 20 Drawn by.New@engineerinc.io Module Voltage V-OC 1 45.3 1 V V-MP 37.13 V DATE: 1111612022 FROM JBOX TO ENPHASE COMBINER BOX Project Name: Maximum Con tinius Current(A) 1 18.15 1 More Than 3 CCCAdjist.Factor 0.8 Adjusted ConductorAmpacity(A) 18.15/0.8=22.69 Keith Eliason Raceway Height From Roof(Temp 39+22=61C)13 1/2" #of wire(#BC*2) 4 Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) 0.71 Property Address: St Temp.Derate Factor(max.continous current divided ambient tem.Factor(A) 22.69*0.71=31.95 Wire Size from NECTable 310.15(b)16 12 AWG 46 dl N E 2nd FROM ENPHASE COMBINER BOX TO MAIN PANEL Fridley, MN 55421 Project: Scale: Total Number Of Microinverters 1 16 1 Total Amps From All Microinverters (A) 16*1.21=19.36 Consider Continuous (A) 19.36*1.25=24.2 PV SYSTEM 11 ASINDICATED Temp.Derate Factor(0.91 at wall of the Building)(A) 24.2/0.91=26.59 Wire Size from NEC Table 310.15(b)16 6AWG Ambiend Tem Factor Per NEC Table 310.15(b)(2)(a) 0.91 P VV 2.O WARNING NOMINAL OPERATING AC VOLTAGE � NOMINAL OPERATING AC FREQUANCY � TURN OF PHOTOVOLTAIC MAXIMUM AC POWER � AC DISCONNECT PRIOR TO MAXIMUM AC CURRENT � WORKING INSIDE PANEL MAXOCERCURRENTDEVICERATING - FOR AC MODULE PROTECTION LABEL 1 PV ARRAY Photovoltaic Power SourceLABEL 19 DO NOT DISCONNECT PV SYSTEM DC DISCONNECT © UNDER LOAD - OPERATING CURRENT B.X LABEL9 OPERATING VOLTAGE - CAUTION: SOLAR CIRCUIT MAXIMUM SYSTEM VOLTAGE - MAIN PV SYSTEM SHORT CIRCUIT CURRENT - DISCONNECT © WARNING LABEL • ' © ECTRIC SHOCK HAZARD© MAIN PV SYSTEM RATED MAX POWER-FONT CURREN - AC DISCONNECT RATED MAX POWER-FONTVOLTAG � THE DC CONDUCTORS OF THIS MAXIMUM SYSTEM VOLTAGE PV SUB-PANEL PHOTOVOLTAIC SYSTEM ARE SHORT CIRCUIT CURRENT � O UNDERGROUND AND MAY BE ENERGIZEDLABEL 11. MAX RATED OUTPUT CURRENT OF - THE CHARGE CONTROLLER IF INSTALLE © SOLAR DISCONNECT WARNING © ELECTRIC SHOCK HAZARDSOLAR PV SYSTEM EQUIPPEDCONTRACTOR WITH RAPID SHUTDOWN DISCONNECTGROUND FAULT IS INDICATE SOLAR ELECTRIC SYSTEM TURN RAPID SHUTDOWN SWITCH TO THE NORMALLY GROUNDED CONDUCTORS CONNECTED MAY BE UNDERGROUND AND ENERGIZED • SHOCK WOLFjRIVER AND REDUCE AWELECTRIC LABEL5WARNING-DUAL POWER SOURCEIN THE ARRAY © SECOND SOURCE IS PV SYSTEM _ _ , .pp 0, WARNING © ELECTRIC SHOCK HAZARD© CAUTION DO NOT TOUCH TERMINALS PHOTOVOLTAIC SYSTEM CIRCUIT 632 LABEL 14 Ile TERMINALS ON BOTH LINE AND LOAD IS BACKFED SIDES MAY BE ENERGIZED IN THE OPENWolf River Electric NE, Isanti, MN 55040 MAIN SERVICE LABEL 15 Phone number: (763)229-6662 POSITION PANEL E-mail: contact@wolfriverelectric.com ® PHOTOVOLTAIC AC DISCONNECT LABEL6MAXIMUM AC OPERATING CURRENT O � O WARNING © MAXIMUM AC OPERATINGCURRENT240V ELECTRIC SHOCK HAZARDLABEL 16 SYSTEM DO NOT TOUCH TERMINALS PHOTOVOLTAIC TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION UTILITY AC DISCONNECT DC VOLTAGE IS ALWAYS PRESENTDrawn by:New@engineerincJo LABEL 17 DATE: 1111612022 Keith Eliason WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT PHOTOVOLTAICPmject Name: 4623 NE 2nd St Fri . - mject Scale: DC DISCONNECT Note: LABELS SHALL COMPLY WITH NEC 6•0Pv SYSTEM L AS INDICATED "Labels shall be weatherproof, durable and permanently mounted" ALL LABELS RED O. Permanently mounted 7PV 3. 1 CAUTION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: DISCONNECTS LOCATED AS SHOWN: SERVICE 1 OF 2 SERVICE 2 OF 2 SERVICE POINT SERVICE POINT CONTRACTOR UTILITY METER UTILITY METER PV SYSTEM DISCONNECT PV SYSTEM DISCONNECT WOLRIVER FOR UTILITY OPERATION FOR UTILITY OPERATION ELECTRIC ENPHASE COMBINER BOX ENPHASE COMBINER BOX Xcel Energy Application#05304632 0 0 Wolf River Electric Address:101 Isanti Parkway 0 o NE, Isanti, MN 55040 \ \ Phone number: (763)229-6662 E-mail:contact@wolfriverelectric.com 0 0 N L4, 0N SOLAR PV ARRAY SOLAR PV ARRAY PLACARD W / \ E W E / \ 4623 NE 2nd St 4623 NE 2nd St CNGINCC�INC Fridley, MN 55421 S Fridley, MN 55421 S DDrawnATE 1111612022g�neerinc.io Project Name: Keith Eliason Property Address: 4623 NE 2nd St Fridley, MN 55421 Project: Scale: Pv SYSTEM AS INDICATED PV 3.2 N 0° j r-:SEND Q MSP................ Main Service Panel MM ............................. Main Meter n D AC .............Utility AC Disconnect W U� E ECB..........Enphase Combiner Box 70 oD D° 90° ao do 10° SCALE: 1/16" = 1'-0" ENGINEErAZINC 133'-6" 3031N Gleno ks Blvd Burbank,CA91502 1 HEREBY CERTIFY THAT THIS PLAN, (747)333-59" new enaineer,rjo SPECIFICATION, OR REPORT WAS PREPARED BY ME OR UNDER MY DIRECT SUPERVISION AND THAT I AM A DULY LICENSED 19-1" PROFESSIONAL ENGINEER UNDER THE LAWS MAIN HOUSE OF THE STAT NESOTA. MSP SIGNATURE: MM C 73'-7" NAME: MANOUICHEHR HAKHA ANESHI 0 E 113 DATE: 06/30/24 LICENSE NUMBER: 58681 DDate Certified and _ °o Signed: 12/08/2022 ° o= CONTRACTOR c� 3 $ w WOL�RIVER z � ° ELECTRIC ' Xcel EnergyApplication#05304632 pp I I o Wolf River Electric Address:101 Isanti Parkway NE, Isanti, MN 55040 Phone number: (763)229-6662 23-8" E-mail: :ontact@wolfriverelectric.com Driveway GARAGE PROPERTY PLAN 133'-6" PROPERTY LINE ENGINEE�INC Drawn by.New@engineerinc.io DATE: 1111612022 Project Name: Keith Eliason Property Address: 4623 NE 2nd St Fridley, MN 55421 Project: Scale: Xcel Energy Application#05304632 PVSYSTEMl AS INDICATED Note: 24/7 Unescorted keyless access is to be provided for ALL UTILITY EQUIPMENT F_PV 4.0 MODULES ON ROOF DESIGN CRITERIA POINT LOAD CALCULATION PER ARRAY Prior to the commencement of work, the contractor shall verify the existing roof and framing Solar Module Modules: Module Weight(Ibs) 48.5 conditions. Notify New@engineerinc.io of any Discrepancies prior to starting construction. 16 #Of Modules 16 Prior to the commencement of work, the contractor shall inspect framing for any damage Attachment Truss 2 x 4 @ 24"O.C. Max Distributed Load: 3 PSF Total Module Weight(Ibs) 776 such as water damage, cracked framing, etc. and These Plans are stamped for structural Plywood &Building Felt Rack Weight(Ibs) 155.2 code compliance of the roof framing supporting the proposed PV installation reference only. Microlnverters Weight Ibs 38.08 1 Layer of METAL ROOF g (Ibs) These plans are not stamped for water leakage. PV modules, racking, and attachment y Total System Weight(Ibs) 969.28 components must follow manufacturer guidelines and requirements. Attachments to be #Of Standoffs 38 installed in a staggered orientation to properly distribute loads. Max Span Between Standoffs (in) 48 Xcel EnergyApplication#05304632 Loading Per Standoff(Ibs) 25.507 pp Total Area (sq.ft.) 352 Note: 24/7 Unescorted keyless access is to be Loading (PSF) 2.75 provided for ALL UTILITY EQUIPMENT - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - ATTACHMENT RAIL _ - - - - - - - - - - Truss 2 x 4 @ 24" O.C. IRONRIDGE L-FOOT DETAIL Ca— CONTRACTOR 0.420'3/8 CNGINCCZINC 1�4 00.75 Engineerinc.io, 03/8-16 x 1" 303 N Glenoaks Blvd — — — — — — — Hex CS SS Burbank,CA 91502 O (747)333-5991 I HEREBY CERTIFY THAT THIS PLAN, 3" new(&enaineednc.io SPECIFICATION, OR REPORT WAS PREPARED — — — — — WOL�RIVER BY ME OR UNDER MY DIRECT SUPERVISION ELECTRIC L FOOT t 031' AND THAT I AM A DULY LICENSED — — — — — — — — — — — — PROFESSIONAL ENGINEER UNDER THE LAWS Xcel Energy Application#05304632 �T OF THE STAT NESO TA. 1.92" SIGNATURE: S—S—S NAME: MANOUCHEHR HAKHAMANESHI Wolf River Electric Top DATE:06/30/24 LICENSE NUMBER: 58681 — — — — — — — Address:101 Isanti Parkway �¢ a""°'s"R�°E°"°` NE, Isanti, MN 55040 Date Certified and — — — — — — — — — Phone number: (763)229-6662 o E-mail:contact@wolfriverelectric.com ® 31.1 Signed: 12/08/2022 — — — — — — — — — — 12.7 — — — — — — — — O 19.1 O ATTACHMENT - - - - - - — - - LAYOUT px,1111 rn,eaded Hoe, Back Left Front Ri ht — O _ _ _ _ _ _ CNGINCGr,,aINC 3.1 Drawn by:New@engineerinc.io O° 7 s I I — — — — DATE: 1111612022 38. p, 12.2 .5 — — _ — — — Project Name: Keith Eliason Property Address: 4623 NE 2nd St General Notes. 2 2 —v Fridley, MN 55421 2 S-S-S Clamp �t _ Project: Scale: 2.M8-1.25 Stainless Steel Hex � I alaa$_2a°staime ssiee�do°nd Will 3 ' 3 PV SYSTEM AS INDICATED Point Setscrew(3116 Hex Drive) q 4 4.Example roof F_PV 5.0 ENPHASE C= 1,08 and IQ8+ Microinverters r Commonly used module pairings, w 235-350 235-440 Module compatibility 60-celIA20 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range 27-37 29-45 Operating range 25-48 25-58 Min/max start voltage 30/48 30/58 Max input DC voltage V 50 60 Max DC current2[module lscj A 15 Overvohage class DC port II DC port backfeed current MA 0 0 - PV array configuration 1x1 Ungrounded array;No additional DC side protection required:AC side protection requires max 20A per branch circuit OUTPUT DATA Peak output power VA 245 300 Max continuous output power VA 240 290 Nominal(L-L)voltage/range3 V 240/211-264 Max continuous output current A 1.0 t21 CONTRACTOR Nominal frequency Hz 60 IQ8 and IQ8+ Microinverters Extended frequency range Hz 50-68 Max units per 20 A(L-L)branch circuft4 16 13 Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- Total harmonic distortion `5° WOLFR 1 V E R defined microinverters with split-phase power conversion capability to convert DC Overvoltage class AC port III power to AC power efficiently.The brain of the semiconductor-based microinverter Easytoinstall ELECTRIC is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with AC port backfeed current mA 30 microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting 1.0 Xcel Energy Application#05304632 55nm technology with highspeed digital logic and has super-fast response times Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Peak efficiency k 97.5 97.6 energy systems. • Faster installation with simple CEC weighted efficiency 'b 97 97 two-Wire cabling Night-time power consumption mw 60 Wolf River Electric Enphase MECHANICAL DATA Address:101 Isanti Parkway High productivity and reliability Ambient temperature range -400Cto+600C(-40°Fto+1400F) NE, Isanti, MN 55040 • Produce power even when the Phone number: (763)229-6662 P Relative humidity range 446to100%(condenslrg)grid is down E-mail:contact@wolfriverelectric.com DC Connector type MC4 • More than one million cumulative Part of the Enphase Energy System. Series IQ8 Series Microinverters redefine reliability Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") P gY Ys Y hours of testing Microinverters integrate with the Enphase 10 standards with more than one million Weight 1.08kg(2381bs) Battery,En phase 10 Gateway.an d th e Enphase cumulative hours of power-on testing, Class 11 double-insulated INVERTER App monitoring and analysis software. enabling an industry-leading liritedwarranty enclosure Cooling Natural convection-nofans of up to 25 years. Approved for wet locations Yes • Optimized for the latest high- DATA SHEET powered PV modules Acoustic noise at 1 m <60 dBA Pollution degree PD3 Mlcrogrid-forming Enclosure Class II double-insulated corrosion resistant polymeric enclosure Complies with the latest Environ.category/W exposure rating NEMA Type 6/outdoor advanced grid support COMPLIANCE ENGINE C-:I,:z INC ConnectPV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for CA Rule 21(UL1741-SA).UL62109-1,UL1741/IEEE1547.FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 Drawnby.New@engineerinc.io IQ8 Series Microinverters using the included PV Rapid Shut Down Equipment and conform DATE: 1111612022 O-DCC-2 adapter cable with I n- la MC4 with various regulations.when installed the latest grid requirements P Pug- P Y e9 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conformswith NEC 2014.NEC 2017,and NEC 2020 section connectors. according to manufacturers instructions. Configurable to support a Wide 690.12andC22.1-2018Rule64-218RapidShutdownofPVSystems.forACandDCconductors.wheninstalledaccordingto Project Name: range of grid profiles manufacturer's instructions. Keith Eliason Property Address: 0 2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo.IQ8 microinverters. Meets CA Rule 21(UL 1741-SA) (1)No enforced DC/AC ratio.See the compatibility calculator at httpsi//Iink.enphase.com/ 4623 N E 2nd St and other names are trademarks of Enphase Energy.Inc.Data subject to change. requirements module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the Ality.(4)Limits may vary.Refer to Fridley, MN 55421 IQBSP-DS-0002-01-EN-US-2021-10-19 local requirements to define the number of microinverters per branch in your area. I08SP-DS-0002-01-EN-US-2021-10-19 Project: Scale: PV SYSTEM AS INDICATED D 6.0 • ENPHASE Install the Enphase IQ8 Series Microinverter To install Enphase IQ8 Series Microinverters,read and follow all warnings and instructions in this guide and in the Enphase IQ8 Series Microinverter Enphase Energy//Rapid Shutdown Installation and Operation Manual at eennhase-com/support Safety warnings are listed on the back page of this guide. The Enphase Microinverter models listed in this guide do not require grounding electrode conductors(GEC),equipment grounding conductors(EGC),or grounded conductor(neutral).The microinverter has a Class II double-insulated rating,which includes ground fault protection(GFP).To support GFP,use only PV modules equipped with DC cables labeled PV Wire or PV Cable Rapid shutdown is built-in IMPORTANT:Enphase IQ8 Series Microinverters require the IQ Cable.An IQ Gateway is required to monitor performance of the IQ Microinverters.The Q Accessories work only with Enphase IQ8 Series Microinverters. Note:After you log in to your Enphase Installer Platform account from Enphase Installer app,Scan the microinverter QR code and connect to the Enphase IQ Gateway to track the system installation progress. The 2014 edition of the National Electrical Code(NEC 2014)added What's new in NEC 2014? new rapid shutdown requirements for PV systems installed on buildings. NEC 2014,Section 690.12 applies PREPARATION t f 10 f t d PV conductors over feet Enphase Microinverters fully meet rapid shutdown requirements in the to )the PV array and requires that the A Download the Enphase Installer App and open it to log D) Check that you have these other items: new code without the need to install any additional electrical equipment. conductors power down to 30 volts _ in to your Enphase Installer Platform account.With this M. 0 ACjunction box. app,scan the microinverter QR code and connect to Tools:screwdrivers,wire cutter,voltmeter,torque wrench,sockets, and 240 volt-amperes within 10 the Enphase IQ Gateway to track system installation and wrenches for mounting hardware seconds of rapid shutdown initiation. progress.To download,go to enphase.com/toolkit or ❑� scan the QR code at right. E) Protect your system with lightning and/or surge suppression devices.It is also important to have insurance that protects against lightning and String inverters require work arounds for rapid shutdown B) Refer to the foseco /tableen-u /suppockPV induce electrical compati- electrical surges. bility at:en_phase_corn/en-uc_/sr�Port/modulezom at�hility. Model DC connector Typical PV module*cell count IF Plan your AC branch circuits to meet the following limits for maximum CONTRACTOR Work around. Work around IQ8-60-2-US MC 4lockin number of microinverters per branch when protected with a 20-amp g type Pair with 60 cell/120-half-cell over-current protection device(OCPD) Specialized Rapid Shutdown String Inverter Installed modules electrical box installed on the on roof,a hostile IQ8PLUS-72-2-US MC-4 locking type Pair with 60 cell/120-half-cell,66 Maximwn*IQ8 Series Microinverters per AC branch circuit(sin- roof cell,or 72 cell/144-hhalf--cell le_ se roof within l0 feet of array. i nviro inverters are of bulling g WOL RIVE R IQ8A-72-2-US IQ8(240 IQ8+ 240 IQBM(240V) nverters are not built IQ8F+240-72-2-US MC-0 locking type Pair with 60 cell/120-half-cell,66 Work around. to live in. IQ8H-208-72-2-US cell,or72 cell/144-half--cell 16 13 11 ELECTRIC Shutoff switch that IS `Enphase IQ8 Series Microinverters are compatible with bi-facial PV modules if IQ8A(24OV) IQ8H(24OV) IQ8H(208V) the temperature adjusted electrical parameters(maximum power,voltage and 11 10 9 1 Energy pp easily accessible to first current ofthe modules,consideri the parameters(i.e., Xcel Ener Application#05304632 rt9 P ( Limits may vary.Refer to local requirements to defne the number of responders on the ground. back side gain),arewithin the allowable microinverter input parameters range. microinverters per branch in your area. ■ C) In addition to the Enphase Microinverters,PV modules and racking, you will need these Enphase IQ8 Series Microinverters: G) Size the b wire gauge i account for voltage rise.Select the correct Work around. Enphase IQ Gateway(model ENV-IQ-AM1-240)communications wire size based ak the distance from the beginning of the Enphase IQ gateway or Enphase IQ Combiner check en hase.com for models): Cable to the breaker in the load center.Design for a voltage rise total Wolf River Electric Extra conduit in Installation. Residential String Inverter Commercial String Inverter 9 y P ( P ) of less than 2%for these sections.Refer to the Voltage Rise Technical is required to monitor solar production. Brief at enohase_com/support for more information. Address:101 Isanti Parkway Tie wraps or cable clips(Q-CLIP-100) NE, Isanti, MN 55040 Enphase Sealing Caps(Q-SEAL-10):for any unused connectors on Best practice:Center-feed the branch circuit to minimize voltage rise in Phone number: (763)229-6662 the Enphase IQ Cable a fully-populated branch. ; • Enphase Terminator(¢TERM-10):one needed at the end of each E-mail: ontact@wolfriverelectric.com Enphase comes standard with rapid shutdown capability AC cable segment Enphase Disconnect Tool(Q-DISC-10) Enphase IQ Cable: ENPHASE RAPID // Cable model Connector PV module Connectors SHUTDOWN All Enphase microln- Enphase microinverters spadng* orientation per box r verters,even those that can safely shut down 5. Q-12-1G-240 1.3m Portrait(all) 240 Terminator COMPATIBILITY were previously installed, automatically,leaving Q-12-17-240 2.Om Landscape(60-and 66-cell) 240 WITH PV inherently meet rapid only low-voltage DC Q-12-20-200 2.3m Landscape(72-cel1) 200 shutdown requirements, electricity isolated to *Allows for 30cm of cable slack no additional equipment the PV module CNGINCC�INC or workarounds needed Enphase IQ Cable Drawn by.New@engineerinc.io AC connector DATE: 1111612022 DC connector 02021 Enphase Energy All rights reserved. Enphase,the Enphase logo,Enphase IQ8 Project Name: Residential Microinverter Commercial Microinverter Series microinverters(IQ8,IQ8+,IQ8A,IQ8H Keith Ellason R `Tie wraps or cable clips and IQBM),Enphase Installer Platform Property Add— Enphase IQ Gateway,and other trademarks 4623 NE 2nd St or service names are the trademarks of Fridley, MN 55421 Enphase En Inc.Data subject to than �—Enphase IQ8 Series Microinverter P &9Y. 1 9e rr11 enphase-, (horizontal installation shown,vertical RevO2-10-23-2021. Project: scale: To learn more, visit 1phase.com L�J E N E R G Y installation also allowed). PV SYSTEM AS INDICATED III III ` AC junction box 140-00195-02 D 7.0 r� 8 � MECHANICAL SPECIFICATION t D V O© Format 74.Oin x 41.11n x 1.261n(Including frame) (1879mm x 1045mm x 32mm) miame,x°t ae•tseemM Weight 48.51bs(22.Okg) Front Cover 0.131n(3.2mm)thermally pre-stressed glass with - - anti-reflection technology ° Goy aa,..ag w.e,.i Back Cover Composite film arrwe,..l Frame Blackarodized aluminum Cell 6 x 22 morocrystallne Q.ANTUM solar half cells ® ov-uoaem.ro Junction Box 2.09-3.98inx1.26-2.361nx0.59-0.711n (53 101 mm x 32-60 mm x 15-18 mm),IP67,with bypass diodes Cable 4mm7Solar cable;(-)>_49.2 in(1250 mm),(-)a49.2 i n(1250 mm) w.men.ru Connector Staubli MC4;IP68 ` 1 W 1 isr-v°s..ro TIoaa^ImmM . • : , ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 M IN IMU M PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TO LERANCE.5 W/-0 W) Powerat MPP' Pam° [bV] 385 390 395 400 405 Short Circuit Curre nt' Isc [A] 11.04 11.07 LIAO U.14 11.17 � E - E Open Circuit Voltage' oc [VJ 45.19 45.23 4527 45.30 45.34 • ° Current at MPP I- [A] 10.59 10.65 10.71 1077 10.83 5 li TOPSMND PY Q*bs Voltage at MPP V_ M 36.36 36.62 36.88 Tt 3739 Efticlency' 4 ]%] 119.6 z19.9 z20.1 >20A a20.6 CONTRACTOR Zeulrore _ MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT Warranty 202f QCELLS Power at MPP R, [W] 288.8 292.6 296.3 300.1 303.8 prmuneltaorrnnw Yield Seadty E Short Circuit Current Isc [A] 8.90 8.92 8.95 8.97 9.00 E Open Circuit Voltage V° M 42.62 42.65 42.69 42.72 42.76 BREAKING THE 20%EFFICIENCY BARRIER Current at MPP I_ [A] B-35 8.41 8.46 8.51 aiK? WOL�RIVER Q.ANTUM DUO Z Technology with zero gap call layout Voltage at MPP V_ [VI 34.59 34.81 35.03 35.25 35A6 ELECTRIC boosts module efficiency up to 20.9%. 'Measurement tolerances P,,°,.t3%;I,,;Vu,;t5%atSTC:1000Wlm°,25t2°C,AM L5according to IEC 60904-3.1800 W/mt,NMOT,spectrum AM 1-5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Xcel Energy Application#05304632 u'=� Atleast98%ofnomnalpowerduring �� --T-----f____- ----T-----i -_ Q CELLS is the first solar module manufacturer to pass the most comprehen- M w first year.Thereafter max 0.5% sive quality programme in the industry.The new"Quality Controlled PV'of g '* ------------- degradation par year.At leasl93.5% a of nominal power W to 10 years.At 1 the independent certification institute TOV Rheinland. F least W%of nominal power up t'0 25 years. INNOVATIVE ALL-WEATHER TECHNOLOGY `-B ti Al data wlthlnmeesuemenitoleram Wolf River Electric- � � 1 0 Optimal yields,whatever the weather with excellent es.Full warranties in accordance with Address:101 Isanti Parkway the warranty terms of the 0 CELLS iaxaownca;wrm l low-light and temperature behavior. o p sales°fganlsellonofyolfrespectIve R NE, Isanti, MN 55040 a country. Phone number: (763)229-6662 veaas Typical module performance under law Irradiance conditions In ENDURING HIGH PERFORMANCE compadsmto STCcondltlms(25•C.1000W/m�) E-mail:contact@wolfriverelectric.com Long-term yield security with Anti LID Technology,Anti PID TEMPERATURE COEFFICIENTS{y� o V Technology',Hot-Spot Protect and Traceable Quality Tra.Q' . Tema a I%/q .0.04 Temperature Coefficient of V_ @ [%/K] -0.27 Tempetamra Coeitiaern o t P,,,:, y I%/KI -0.34 Nominal Module Operating Temperature NMOT [°F] 109t5.4(43t3°C) J/y7 EXTREME WEATHER RATING o C/7LryJ( High-tech aluminum alloy frame,certified for PROPERTIES FOR SYSTEM DESIGN MODULE high snow(5400Pa)and wind loads(4000Pa). Maximum System Voltage V.,s M 1000(IEC)/1000(UL) PV module classification Classll 9 DATA SHEET Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 61730 TYPE2 A RELIABLE INVESTMENT al Max.Design Load,Push/Pull' Rbs/ftj 75(3600 Pa)/55(2660 Pa) Permitted Module Temperature -40°F up to.185'F p �e'eeee��f Inclusive 25-year product warranty and 25-year Max.Test Load.Push/PuIN [Ibs/ft�J Lt3(5400Pa)/84(4000 Pa) °n Continuous Duty (-40°C up to+85°C) linear performance warranty'. 'See installation Manual 6 `APT lest sheet on reef f conditions accordingfor further nfamurlon ordingto lEC/T5 628 0 4-12015.methodA(-1500V,98h) 'See data ghee[ QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION f` CNGINCCr=aINC UL61730.cEcompl-T IY�y Drawn by:New@engineerinc.io roal oam"CmualeaPv-Twtana.,mm, �,[�,j// o-o "'.:=I Q DATE: 11/16/2022 IEC612L&c+"6,IEC6173Q2M6, /i /� THE IDEAL SOLUTION FOR: US.P.W1No.9.693215(sdacros), (me ( E Horizontal 76.4in 43.31n 48.OIn 18581bs 24 24 32 fi acPVC-ircatbnmgoing Oc us ♦ packaging 1940mm 1100mm 1220mm 751kg pallets pallets modules Project Name: Rcollcpanayscm "`°.a onmm% ,R Keith Eliason Lrl resldentlel buildings Properly Address: Note:Installation lretiuctlms must be followed.See the installation and operating manual or contact our technical service department fat further lnformatlm on approved Installation and use of 4623 NE 2nd St .is product. Fridley, MN 55421 GICELLS 400 spectrum Center Drleel Suite Project: Scale: Engineered]n Germany 400SpeciumCente Drive,Surte1400,Irvxe,C492618,USAITEL 3 949 748 59 96 1EMAILInqulry�s.gcels.comlWEBwww.4celk.us PV SYSTEM AS INDICATED D 8.0 Snap rack- UR-40 SnapNrack Ultra Rail UR-60 A sleek' straightforward rail solution for mounting solar modules on all roofRail Solar Mounting Solutions features two rail profiles; UR-40 is a lightweight rail profile that is suitable geographic Ultra Rail • = ••s. duty rail modulempatible with all existing mounts, The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge CONTRACTOR Unparalleled Wire Management 4 • Open rail channel provides room for running wires resulting in a long-lasting quality install WOL�RIVER Industry best wire management offering ELECTRIC includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Xcel Energy Application#05304632 Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard Wolf River Electric Address:101 Isanti Parkway NE, Isanti, MN 55040 • Phone number: (763)229-6662 Industry ' . • • Wire &N Mounts • • Heavy Duty UR-60 Rail E-mail:contact@wolfriverelectric.com Management Solutions • • • - • UR-60 rail profile provides increased span capabilities for high wind speeds and snow loads RACKING Single • • l Installation All SnapNrack • • • Taller, stronger rail profile includes profile- DATA SHEET Clamps • specific rail splice and end cap are compatible with • All existing mounts, module clamps, and accessories are retained for the same great both rail profiles install experience ENGINEEr-:ZIN Drawn by:New@engineerinc.io DATE: 1111612022 - Start Installing Ultra ail Today Project Name: Keith Eliason Quality. Innovative . Superior. 4623 Property A NE ddress: 2nd St RESOURCES snapnrack.com/resources SnapNrack Solar Mounting Solutions are engineered to optimize material use and Fridley, MN 55421 DESIGN snapnrack.com/configurator Project Scale labor re • and improve overall installationquality and safety. Pv SYSTEM AS INDICATED WHERE TO BUY snapnrack.com/where-to-buy � 2019 by SnapNrack Solar Mounting Solutions.All rights reserved F—D 9.0 The strength of the S-5-S clamp is in its simple design. The patented setscrews will slightly dimple the metal seam material S=510 leaving but pierce roof warranties intact. The Right Way!' The 5-5-S and S-5-S Mini clamps are each furnished with S—5—S Clamp the hardware shown to the right.Each box also includes The Right Way! a bit tip for tightening setscrews using an electric screw M13-1.25 X 16.00 mm gun.A structural aluminum attachment clamp,the S-5-S Hex Flange Bolt • is compatible with most common metal roofing materials excluding copper.All included hardware is stainless \, steel.Please visit www.5-S.com for more information - - including CAD details,metallurgical compatibilities and The S-5-S clamp was created specifically specifications. for popular snap-together profiles— U) including residential profiles byTaylor The 5-5-5 clamp has been tested for load-to-failure -� results on most major brands and profiles of standing Metals and - • • Standing seam roofing.The independent lab test data found at Threaded Hole f;N (2x)MO-1.25 • • • www.S-5.com can be used for load-critical designs and CONTRACTOR Firestone(like the or applications.S-5!0 holding strength is unmatched in the q • • . • avoid industry.Profiles that are shaped as illustrated below will • necessity of crimping the work with the S-5-S and S-5-5 Mini.In order for the S-5-S simpleIts • • size make it or S-5-S Mini to fit these types of seams,the finished seam �dAl WO L RIVE R • • • • must: C$ J Two Round-Point X Sets ELECTRIC products • ' ' Beat least 1.00"high. ' Round-Point Setscrews applications. • • Have a height distance less than ore equal to 0.25" Energy pp E as _ 9 9 Xcel Ener Application#05304632 setting patented • • •• between the male portion of the panel and female • setscrews into the clamp,placing the clamp on portion of the panel. S-5-S Mini Clamp them• to the specified tension. usingancillary items the bolt provided Example Profiles Wolf River Electric with the product.Go to Address:101 Isanti Parkway www.S-5.com/tools for • • • NE, Isanti, MN 55040 tools • ,. - . properly . Phone number: (763)229-6662 • . • . clamps. E-mail:contact@wolfriverelectric.com • � • • S-5-S Mini e ono Clamp O R ATTACHMENT The S-5-S Mini is a bit shorter than the0 �:- DATA SHEET • os �: all kinds of rooftop accessories:signs, • rooftop •satellite.The mini is the choice for attaching ••protection• j 04 CNGINCC;:ZINC • ' arrays,exhaust stack created specificallyfor Drawn by:New@engineerinc.io bracing,conduit,condensate popular snap-together DATE: 11/16/2022 mechanical • • about • • • Please note:All measurements are rounded to the second decimal place. Project Name: anythinKeith Eliason • 5-51-Warning!Please use this product responsibly! Distributed by Property Address: 'S-S!mini clamps are not compatible with.and should not .• Products are protected by multiple U.S.and foreign patents.Visit the website at www.5-5.com for 4623 NE 2nd St omplete information on patents and trademarks.For maximum holding strength,setstrews should ,� betensianed and re-tensi ned as the seam material compresses.Clamp setscrew tension should he Fridley, MN 55421 retention systems. verified usinga ,brated torquewrench between 160and 180inch pounds when used on 22ga steel, •• andbetween 130and150inch poundsforall other metals andthi nner gauges of steel.Consult the 5 51 Project: Scale: .. websiteat—S-5—fmrpubisheddamregardingholdingstrength. PV SYSTEM AS INDICATED Capyright2011 MetalRaoflnmvaliens Lrl.S-5l prod uctsare poem prof td. SSlaggressivelypro[ec[sitspazerrts,trademarksmd mpyrights.Venian081721. FD 10.0 0.0 Enphase IQ Combiner 4/4C MODEL NUMBER Enphase Networking IQ Combiner 4(X-1 Q-AM 1-240-4) IQ Combiner 4 with Enphase IQ Gateway printed circurt board for integrated revenue grade PV production metering(ANSI C1220+/-0.5%)and consumption monitoring(+/-25%).Includes a silversolar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C(X-IQ-AM1-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C1220+/-0.5%)and consumption monitoring(+/-2.5"0).Includes Enphase Mobile Connect cellular modem (CELLMODEM-Ml-06-SP-05),a plug-and-play industrial-grade cell modem for systems upto 60 microinverters. (Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in Enphase The Enphase IQ Combiner 4/4C with Enphase the installation area.)Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. IQ Gateway and integrated LTE-M1 Cell ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Q Combiner 4/4 C Ensemble Communications Kit Includes COMMS-KIT-01 and CELLMODEM-Mt-06-SP-05 with 5-year Sprint data plan for modem(included only with IQ Combiner 4C) COMMS-CELLMODEM-Ml-06 Ensemblesites CELLMODEM-M1-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan X-IQ-AM1-240-4 consolidates interconnection equipment CELLMODEM-Ml-06-AT-05 -4GbasedLTE-M7 cellular modem with 5-year AT&T data plan X-I A M 1-240-4C Circuit Breakers Supports Eaton BR21Q BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. Q- into a single enclosure and streamlines IQ BRK-10A-2-240V Circuit breaker,2 pole,IOA,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,l5A,Eaton BR215 microinverters and storage installations by BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,l5A,Eaton BR215B with hold down kit support providing a consistent,pre-wired solution for BRK-20A-2P-24OV-B Circuit breaker.2 pole,20A,Eaton BR220B with hold down kit support residential applications. It offers up to four EPLC-01 Power line carrier(communication bridge pair),quantity-one pair j XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C 2-pole input circuits and Eaton BR series XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) busbar assembly. XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board(PCB)for Combiner 4/4C X-I Q-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. CONTRACTOR ELECTRICAL SPECIFICATIONS Smart Rating Continuous duty Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Hz Includes Enphase Mobile Connect cellular modem Eaton BR series twsbar rating 125 A WO L�R I V E R (CELLMODEM-M1-06-SP-05),Included only with IQ Max.continuous current rating 65 A E L E CT R I C Combiner4C Max.continuous current rating(IputfromPV/storage) 64A Includes solar shield to match Enphase IQ Battery Max.fuse/circuit rating(output) 90 A Xcel Energy Application#05304632 aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Flexible networking supports Wi-Fi, Max.total branch circuit breaker rating(input) BOA of distributed generation/95A with IQ Gateway breaker included E Ethernet,or cellular Production metering CT 200 A solid core pre-installed and wired to IQ Gateway i Optional AC receptacle available for PLC bridge Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers 4, Provides production metering and consumption Wolf River Electric L monitoring MECHANICAL DATA Address:101 Isanti Parkway Dimensions(WxHxD) 37.5 x 49.5 x16.8 cm(14.75'x 19.5'xb.67).Height is 21.06"(53.5 cm)with mounting brackets. NE, I santi, MN 55040 Simple Weight 7.5 kg 0 6.5 lbs) Phone number: (763)229-6662 Ambient temperature range -400Cto+460C(-400to1150F) E-mail:contact@wolfriverelectric.com Centered mounting brackets support single Cooling Natural convection,plus heat shield A stud mounting I Enclosure environmental rating Outdoor,NRTLcertifled,NEMA type 3R polycarbortate construction a, Supports bottom,back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC Wire sizes 20 A breaker input: to 4 AWG copper conductors E N P HAS E •60A brbreakeakerbranch inpirt:4 to to1/OAWGcopperconductors • _ plug-In breakers(not Included) Main lug combined output:10 to 2/OAWG copper conductors AC COMBINER BOX X-IQ-AM1-240-4C 80A total PV or storage branch circuits Neutral and ground:14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. DA TA`+H E E T L. Ahrtude To 2000 meters(6,560feet) v7 bi Reliable INTERNET CONNECTION OPTIONS 1 Integrated%+1 8021lb/g/n • Durable NRTL-certified NEMA type 3R enclosure ear Five- limited warrant Cellular CELLMODEM-MI-06-SP-05,CELLMODEM-Ml-06-AT-05(4G based LTE-Ml cellular modem).Note thatan Enphase y y Mobile Connect cellular modem is required for all Ensemble installations. L Two years labor reimbursement program coverage Ethernet Optional,802.3,Cat SE(or Cat 6)UTP Ethernet cable(not included) Drawn by.New@engineerinc.io included for both the IQ Combiner SKU's b UL listed COMPLIANCE DATE: 1111612022 Compliance,IQ Combiner UL 1741,CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Project Name: Production metering ANSI C12.20 accuracy class 0.5(PV production) 4 Keith Eliason Consumption metering:accuracy class 25 d' Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 Property Address: U� 4623 NE 2nd St x-IQ-AM1-24O-4 Fridley, MN 55421 usrEo ' ENPHASE ENPHASE. To team more about Enphase offerings,visit enphase.com u To learn more about Enphase offerings,visit enohase.t�m �./ Project: Scale: 0 2D21 Enphase Energy All rights reserved Enphase,the Enphase logo,IQ Combiner 4MC,and other names are trademarks of PV SYSTEM AS INDICATED Enphase Energy,Inc.Data subject to change 1G-21-2021 D 11 .0 CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE Certificate Number 20180530-E341165 Certificate Number 20180530-E341165 Report Reference E341165-20171030 Report Reference E341165-20171030 Issue Date 2018-MAY-30 Issue Date 2018-MAY-30 Issued to: ENPHASE ENERGY INC This is to certify that representative samples of the product as specified on this certificate were tested 1420 N McDowell Blvd according to the current UL requirements. Petaluma CA 94954-6515 Permanently-connected, Grid Support utility Interactive,208V single-phase, 240V single phase evaluated for use on a split phase system, distributed resource power system. This is to certify that STATIC INVERTERS, CONVERTERS AND representative samples of ACCESSORIES FOR USE IN INDEPENDENT POWER Models 2-2-U,land IQ7 -72, and IQ7X 96.followed by 2, 5,-B. or-ACM,followed by US+. Models IQ7PD-72-2-US and IQ7PD-84-2-US. SYSTEMS, PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM EQUIPMENT USL/CNL—Photovoltaic Rapid Shutdown Equipment. See Addendum CONTRACTOR Models IQ7-60,IQ7PLUS-72, and IQ7X-96,followed by-2,-5,-B, or-ACM,followed by-US+. Models IQ7PD-72-2-US and IQ7PD-84-2-US. Have been investigated by UL in accordance with the +may be followed by additional characters not affecting safety Standard(s) indicated on this Certificate. WOL�RIVER Standard(s)for Safety: ELECTRIC Standard(s)for Safety: See Addendum UL 62109-1,SAFETY OF POWER CONVERTERS FOR USE IN PHOTOVOLTAIC POWER Xcel Energy Application#05304632 Additional Information: See the UL Online Certifications Directory at SYSTEMS-PART 1: GENERAL REQUIREMENTS www.u1.com/database for additional information CSA C22.2 NO. 107.1-01, GENERAL USE POWER SUPPLIES IEEE 1547 INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Wolf River Electric Only those products bearing the UL Certification Mark should be considered as being covered by UL's Address:101 Isanti Parkway Certification and Follow-Up Service. IEEE 1547.1 IEEE STANDARD CONFORMANCE TEST PROCEDURES FOR EQUIPMENT NE, Isanti, MN 55040 Look for the UL Certification Mark on the product. INTERCONNECTING DISTRIBUTED RESOURCES WITH ELECTRIC POWER SYSTEMS Phone number: (763)229-6662 UL 1741. INVERTERS,CONVERTERS, CONTROLLERS AND INTERCONNECTION SYSTEM E-mail:contact@wolfriverelectric.com EQUIPMENT FOR USE WITH DISTRIBUTED ENERGY RESOURCES CEC-300-2011-005,-CMF GUIDELINES FOR CALIFORNIA'S SOLAR ELECTRIC INCENTIVE PROGRAMS PURSUANT TO SENATE BILL 1 INVERTER CERTIFICATION ENG I NEEr-:2 I Nr�_ Drawn by:New@engineerinc.io DATE: 1111612022 /]������� Project Name: Blum Mdvnlidt Dvacla Nonh An 11c Cvr A1c Progan I &ucv MahieiJ�ule.Drvcla lJonh Amancan CaniEcaoon P�ogam 1 Keith Eliason UL LLC U �` UL LLC Property Address: Anylnformdlw end doai d ion invdmy U L Mafi services a re pr dadon WAf of UL LLC LULtm arty ixllwrizuf l--,of U L For quvstlans.plea» Anylnfnmdlw and—mall,invdmg U L M1k svrvices are Provided on twhdl of UL LLC(UL)a ary aM har Uvd Ycensee d UL Fm Wa k,b p4v 4623 NE 2nd St mrt act a local UL Cuvarwr Set IRaprvsattdlvv at 1dWPul.caNabmadilocaI—, contacts bcal UL CUWomar Saiv.cv Rvprasei 11.al Lca doulullocatro Fridley, MN 55421 Page 1 of 2 Page 2 of 2 Project: Scale: PV SYSTEM AS INDICATED Created by UL Document Assembler 2018-07-05 15:07:07-05:00 Created by UL Document Assembler 2018-07-05 15:07:07-05:00 F-D 12.0 f f II L#J ,♦ Surge Protection 'ART NUMBER MNSPD-115 MNSPD-300-AC MNSPD-300-DC MNSPD-600 Nominal Voltage 0 to 90 VAC 0 to 250 VAC 0 to 300 VDC 0 to 480 VAC 0 to 1 15 VDC 0 to 600 VDC _ MCOV 180V 470V 470V 780V Surge Protection You Can / _ 1 VPRLinetoGround 600V 1200V 1200V 1800V 1 Suggested Placement Up to 90VAC circuits, 120/240 VAC circuits Off-grid PV combiners 316V/480 VAC circuits Count O n• 12V,24V,48VDC battery Charge controller inputs Grid-tie PV combiners circuits up to 30OVDC Grid-tie inverter input Non-Isolated Inverters MidNite Solar Surge Protection Devices are type 1 devices, designed for indoor and outdoor Type UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 UL14494th Ed.Type 1 applications. Engineered for both AC and PV Diagnostic Blue LED MNSPD-300-AC DC @I@CtrlCal systems, they rOVld@ protection LED indicates when voltage is present between L1 +ground and L2+ground y y P P MNSPD-115,MNSPD-300-DC and MNSPD-600: to service panels, load centers or electronic LED indicates when voltage is present between L1 +L2(PV+PV-) devices that are directly connected to a MidNite Thermal Disconnector Internal Fuse Surge Protection Device (SPD). Response Time <1 micro sec. MI CONTRACTOR MidNite's SPDs are offered in four models to ;y protect a variety of different voltage ranges. -- They achieve this protection by clamping surge MNSPD300ACFM (Cut-in box) WOL�RIVER voltage to a level that your system can sustain (MNSPD-300-AC included) ELECTRIC without damaging the components of the Performance System. Surge Current Rating per Phase 80kA Xcel Energy Application#05304632 03.527" Short Circuit Current Rating 10kA Compare our SPDs against other surge protec- Fusing Individually fused MOVs tion devices. You will see there is no com ari- Thermal Fusing Yes p Over current Fusing Yes Wolf River Electric son in both our price and features. All our SPDs Operating Frequency 0 to 500 Hz Address:101 Isanti Parkway are made in the USA and have a 5 year warranty. Mechanical Description NE, Isanti, MN 55040 Enclosure Polycarbonate UL94V-0 Phone number: (763)229-6662 Environmental Rating Type4X E-mail:contact@wolfriverelectric.com With lightning you only et one Weight Connection Method #1b AWG 9 9Y Y9 l Mounting Method 1/2"Conduit Knockout chance, so get the best! 3.82„ Operating Altitude Sea Level- 12,000'(3,658 Meters) 4.425" Storage Temp -40,Fto+185 F(-40°Cto+85,Q SURGE PROTECTION Operating Temp -40,F to+185,F(-40°C to+85,C) Diagnostics Four Models: Blue status LED,one per leg Listings and Performance 24"Wires CNGINCC�IN MNSPD-115 UL Standard for Safety,UL 1449 Surge Protective Devices-Fourth Edition CSA C22.2 No.8-M1986 Electromangetic Interference(EMI)Filters,Fourth Edition Drawn by:New@engineerinc.io MNSPD-300-AC I DATE: 1111612022 MNSPD-300-DC Project Name MNSPD-6V0 Model No. Max Operating Surge Current Configuration MCOV SCCR VPR 600V/3kA Keith Eliason Voltage i per Phase i I - L G Property Adieess: MNSPD-115 100 VAC/150VDC 4 80kA 1,0 3 wire(2 Legs) 180V L-N IOkA 600V - MNSPD-300-AC I 300VAC 80kA 1 3-wire 2 Les 470V L-N 10kA 1200V I��IITE MNSPD-300-DC_ 385VDC 180kA 1 3-wire 2 Les 470V L-N 10kA 1200V �) MNSPD-600 480VAC/600VDC 80kA . 1 ,3-wire 2 Les 780V L-N 10kA 1800V Project: Scale: www.mldnHesolar.comispd �11 aA� PV SYSTEM AS INDICATED 17722 67thAve.NE.,Arlington,WA.360-403-7207 FAX:360-M-6862 <,SxE www.midnitesolar.com/spd 17722-67th Ave NE.Arlington.WA 98223 PH. 360403-7207 FAX 360-691-6862 FD 13.0 WITNESS TEST PROCEDURE Keith Eliason A TEST PROCEDURE THAT WILL BE USED TO VERIFY THE PROTECTION AND OPERATION OF THE SYSTEM SHALL BE SUBMITTED TO XCEL ENERGY FOR APPROVAL.THE PROCEDURE INCLUDES AN ANTI-ISLAN DING TEST(FOR ALL SYSTEMS)TO VERIFYTHE SYSTEM CEASES GENERATING IN PARALLEL WITH THE XCEL ENERGY 4623 NE 2nd St,Fridley,MN 55421 DISTRIBUTION SYSTEM WHEN THE UTILITY SOURCE IS LOST.EACH SYSTEM IS UNIQUE AND WILL REQUIRE A CUSTOMTEST PROCEDURE BASED ON THE INVERTER MANUFACTURER'S RECOMENDATIONS FOR COMISSIONIND AND ANTI-ISLANDING.IN ADDITION TO THE MANUFACTURER'S RECOMENDATIONS. UTILITY:XCEL ENERGY ALLTESTING SHALL BE PERFORMED BY QUALIFIED PERSONELLONLY PHOTOVOLTAIC PROJECT INFO PV MODULE:(16)HANWHA 40OW STEPS TO VERIFY PV SYSTEM IS READYTO BE ENERGIZED: INVERTER: 1.SITE SECURITY 1-PHASE 120/240 -SITE SHOULD HAVE 24/7 KEYLESS ENTRYAND DRIVABLE ACCESS IF XCEL EQUIPMENT IS PRESENT WITHIN THE SITE FENCE (16)IQ8+MICROINVERTERS -IF APPLICABLE,SITE SHOULD HAVE 24/7 DRIVABLE ACCESS TO ANY XCEL EQUIPMENT INSTALLED OUTSIDE OF THE SITE FENCE THAT IS USED FOR THE SOLE 6.40Kw(DC) PURPOSE OF FEEDING THE PV SYSTEM ARRAY 1AZIMUT:90(12) ARRAY 2 AZIMUT:270(4) 2.PROPER LABELLING VERIFY LABELING FOR THE MAIN SERVICE PANEL,PV SYSTEM CIRCUIT BREAKER,DC DISCONNECT(WHEN APPLICABLE),UTILITY AC DISCONNECT,PRODUCTION METER AND OTHER RELEVANT LABELLING AND SIGNAGE. ARRAY TILT:30 3.ENERGIZE THE PV SYSTEM BY CLOSING THE UTILITY DISCONNECT. PLEASE ALLOW 5-MINUTE FOR THE INVERTER TO BOOT-UP. NEC 2020/IRC 2018/IBC 2018 WOLF RIVER ELECTRIC COMPANY 4.WHILE IN NORMAL OPERATION,REFER TO THE REFERENCE POI NTOF APPLICABI LITY TO VERIFY THE VOLTAGES AT THE INVERTER AC OUTPUT ARE WITHIN 5%OF THE COMBINED INVERTED AC VOLTAGE RATINGS AND ALL INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE"NORMAL." 101 ISANTI PARKWAY NE#G ISANTI,MN 55040 5.WHILE I N NORMAL OPERATION,VERI FY THAT ALL INVERTERS ARE OPERATIONAL AN D PRODUCI NG POWER.VERI FY THAT SYSTEM IS GEN ERATI NG AT FULLEST CONTACT@WOLFRIVERELECTRIC.COM REASONABLE CAPACITY.WHILE I N NORMAL OPERATION VERI FY THE VOLTAGES AT THE DER AC TERMI NALS ARE WITHIN 5%OF THE COMBI NED DER AC VOLTAGE WOLFRIVERELECTRIC.COM CONTRACTOR RATINGS AND ALL LEDs,ALARMS AND/OR LCD CODES ARE"NORMAL" 6.SIMULATE THE LOSS OF UTILITY SOURCE FOR THE ANTI-ISLANDING TEST BY OPENING THE"UTILILITY AC DISCONNECT". Keith Eliason WOL�RIVER 7.USING A VOLTMETER,VERIFY THE VOLTAGE ATTHE INVERTER SIDE OF THE AC DISCONNECT HAS DROPPEDTO ZERO WOLF RIVER SOLAR ELECTRIC CASE#05304632 Xcel Energy Application#05304632 NOTE:ONLY CUSTOMER-OWNED EQUIPMENT SHALL BE USED FOR THIS VERI FICATION. 24/7 UNESCORTED ACCESS SHALL BE 8.USING AN AMMETER OR THE INVERTER'S DISPLAY,VERIFY THE DER OUTPUT OF THE INVERTER HAS CEASED WITHIN TWO SECONDS. PROVIDED FOR THE METERS&AC DISCONNECT Wolf River Electric 9.VERIFY INVERTER LED'S,ALARMS,AND/OR LCD CODES ARE APPROPRIATE FOR LOSS OF UTILITY SOURCE Address:101 Isanti Parkway METERS&UTILITY DISCONNECT WITHIN NE, Isanti, MN 55040 10.RESTORE THE LOST UTILITY SOURCE BYCLOSINGTHE"UTILITY AC DISCONNECT" 10'&LINE OF SIGHT Phone number: (763)229-6662 E-mail:contact@wolfriverelectric.com 11.VERIFYTHATTHE INVERTER SYSTEM DELAYS 5 MINUTES BEFORE RESUMING POWER OUTPUTAFTERTHE UTILITY SOURCE IS RESTORED UTILITYAC DISCONNECT IS VISIBLE LOCKABLE&READILY ACCESSIBLE 12.VERIFY FIXED POWER FACTOR SETTINGS FOR EACH INVERTER MEETTHE PROJECT REQUIREMENTS WITNESS TEST GROUND SNOW:50PSF PROCEDURE 13.METERTECH HAS VERIFIED METERING EQUIPMENT WIND SPEED:115MPH EXPOSURE CATEGORY:B 14.SYSTEM RESUMED DELIVERY OF POWER NO LESS THAN 5 MINUTES AFTER UTILITY SOURCE IS RESTORED PV ARRAY:2.75 PSF PRODUCTS: CNGINCCI�INC RAILS:SNAPNRACK Drawn by.New@engineerinc.io MOUNTS:S5-S DATE: 1111612022 ROOF-MOUNT Project Name: Keith Eliason Property Address: 4623 NE 2nd St Fridley, MN 55421 Project: Scale: PV SYSTEM AS INDICATED F-D 14.0 MDEPARTMENT OF LABOR AND INDUSTRY Wiring Methods and Disconnecting Means ❑ Are the conductor and cable ampacities determined at 125%before adjustment factors?690.8(B) Solar PV Inspection Checklist ❑ How are the PV Source and Output Circuit protected from overcurrent?690.9 ❑ Do AC or DC OCPD's have the appropriate voltage, current and interrupt ratings?690.9 Solar PV Inspection Checklist for REI#ELE- Installer Wolf Rlver Electric Job Address4623 NE 2nd St City/Township Fridley, MN 55421 ❑ Has arc-fault circuit protection been provided for DC source and/or output circuits?690.11 Required Documentation ❑ Is a rapid shutdown required and if so, how is it accomplished and identified?690.12&690.56(C) •Manufacturer's specifications for the inverter ❑ Is the PV disconnect permanently marked and installed in a readily accessible location?690.13 •Manufacturer's specifications for the module •Manufacturer's specifications for the optimizer(if used) ❑ Are the Isolating devices or equipment disconnecting means installed in circuits connected to •Verification that the racking system grounding and bonding is listed equipment at a location within the equipment,or within sight and 10 feet of the equipment?(Where PV Inverter the maximum circuit current is greater than 30 amperes an equipment disconnecting means shall be CONTRACTOR provided for isolation.)690.15 ❑ Is the PV system utility-interactive,stand alone or multimode?690.2 Q Has the fuse disconnecting means, if required, been installed?690.15 and 240.40 ❑ Is all the equipment listed for PV application?690.4 ❑ Are PV source or output circuits>30 volts in a raceway or guarded if readily accessible?690.31 WOLFRIVER ❑ Is the system grounded, ungrounded or(functionally grounded)?690.2 and 690.41 ❑ Is single conductor cable used outdoors Type USE-2 or listed&labeled PV wire?690.31 ELECTRIC ❑ Has DC Ground-Fault Protection been provided and properly labeled?690.41(B)? ❑ Are PV source or output circuits on or inside a building in a metal raceway and marked?690.31 Xcel Energy Application#05304632 ❑ What is the maximum PV system voltage?690.7 ❑ Is all listed equipment rated for the maximum voltage?690.7 Interconnection Wolf River Electric ❑ Determine the maximum circuit current for the PV Source and Output Circuit; Inverter Output Circuit; Q Has a plaque or directory been installed at each disconnecting means(capable of interconnection) Address:101 Isanti Parkway Inverter Input Circuit;and DC to DC Converter Output(refer to inverter documentation).690.8 denoting NE, Isanti, MN 55040 all electric power sources&power production sources. 705.10 Phone number: (763)229-6662 ❑ Has the point of connection to other sources been installed per 705.12? E-mail:contact@wolfriverelectric.com System Grounding ❑ Is the supply side disconnect readily accessible and within 10'of the connection point?705.11 ❑ Are all exposed non-current carrying metal parts of the PV system grounded?690.43 and 690.47 Q Are the utility interactive inverters connected to the system through a dedicated circuit breaker or PV INSPECTION ❑ Are the mounting structures or systems used for equipment grounding?690.43 fusible disconnecting means?705.12 CHECKLIST ❑ Does the bus or conductor ampacity comply with 705.12? ❑ Are the interconnecting devices used for equipment grounding listed and identified?690.43 ❑ Are the EGC properly sized and protected if exposed and not smaller than#6?690.45,690.46, Q Have all the required labels been applied?(See separate label list.) 690.50,250.122, 250.120(C) CNGINCCr,:aINC Drawn by.New@engineerinc.io ❑ Has the grounding electrode system been installed?690.47 DATE: 1111612022 ❑ If both are present, has the DC grounding electrode system been bonded to the AC GES?690.47(A) Project Name: Keith Eliason Property Address: 4623 NE 2nd St 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.mn.gov Fridley, MN 55421 443 Lafayette Road N.,St.Paul,MN 55155•(651)284-5005•www.dli.m n.>?ov sdarchecklo NEC2020Salar_Checkllst Checked 2=0317 Project: Scale: 1 2 PV SYSTEM AS INDICATED D 15.0