Loading...
HomeMy WebLinkAboutca tech2 (1) Spacing Recommendations Spacing Recommendations for Bowing Spacing Recommendations for Bowing Backfill ll Backfill Wall Height(ft) Elevation Elevation Below Top Courses Courses Courses Courses Below Top of Wall(ft) 7"-4" 8"-0" 8"-8" 9"-4" of Wall(ft) 8 9 10 Full Backfill 4.67 4.00 2.67 2.00 Full Backfill 5.00 4.50 2.50 1 4.67 4.67 4.00 2.67 1 5.00 5.00 3.50 2 4.67 4.67 4.67 4.00 2 5.00 5.00 5.00 3 4.67 4.67 4.67 4.67 3 5.00 5.00 5.00 4 4.67 4.67 4.67 4.67 4 5.00 5.00 5.00 5 4.67 4.67 4.67 4.67 5 5.00 5.00 5.00 Spacing Recommendations for Bowing Spacing Recommendations for Bowing 1 1 Poured Backfill ht Backfill Wall Height(ft) Elevation Elevation Below Top Courses Courses Courses Courses Below Top of Wall(ft) 7"-4" 8"-0" 8"-8" 9"-4" of Wall(ft) 8 9 10 Full Backfill 4.67 4.67 4.00 2.67 Full Backfill 5.00 5.00 3.50 1 4.67 4.67 4.67 4.00 1 5.00 5.00 5.00 2 4.67 4.67 4.67 4.67 2 5.00 5.00 5.00 3 4.67 4.67 4.67 4.67 3 5.00 5.00 5.00 4 4.67 4.67 4.67 4.67 4 5.00 5.00 5.00 5 4.67 4.67 4.67 4.67 5 5.00 5.00 5.00 (1) Spacing tables have been developed with consideration for the recommendations of ACl 440,design calculations,and current industry state of practice.The carbon fiber straps are to be installed per the installation instructions and must be the full height of the wall. (2) Listed spacing is center-to-center.Maximum recommended spacing from corners is 3 feet but should also not exceed the spacing of the interior straps. (3) Spacing could be less than listed in the above charts based on the condition of the wall and severity of the displacement. (4) Listed wall heights include the full height from top of footing to top of wall.Spacing recommendations assume the bottom 4 inches of the wall are restrained by an interior concrete slab. (s) Recommended spacing assumes the backfill soils exert an equivalent fluid pressure(EFP)equal to 60 psf/ft.The design professional may choose to consider alternate EFP values based on project-specific conditions. (6) Poured concrete walls most often show signs of distress by leaning instead of bowing. Leaning concrete walls are often intact and typically show maximum inward movement at the top of the wall. Leaning concrete walls may not benefit from carbon fiber strengthening and should consider alternate design recommendations to address the deficient connection at the top of the wall. (7) Because variations in building design and construction materials are common,CarbonArmor applications should be reviewed by a qualified professional. 02021 Supportworks® Appendix3C All Rights Reserved 310 CarbonArmor®Wall Reinforcing System