HomeMy WebLinkAboutDAVID GAMRADT - Permit Plans ALL
TOTAL ROOF SURFACE AREA E N E R G Y
(PLAN VIEW):1,519 SQ FT
TOTAL
RFACEA EA(PLAMODULE COMPANY INFORMATION
SURFACE AREA(PLAN VIEW)
378.36 SQ FT
r ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
DAVID GAMRADT
6381 MADISON ST NE
FRIDLEY, MN 55432
PO 66150
Panel Type
JA 395
# of Panels
18
System Size (kW)
7.11
FLUSH ROOF MOUNT
NOTES:
1. (18)ENPHASE IQ 8M
INVERTER(S)
2.ARRAY 1:
20'TILT.269°AZIMUTH
/
/ AZIMUTH
REVISIONS
LAST:02/20/23 AH
PROJECT-PAGE TITLE
COVER PAGE
PAGE NUMBER
AO
SOUTH ELEVATION ALL
ENERGY
COMPANY INFORMATION
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
DAVID GAMRADT
6381 MADISON ST NE
FRIDLEY, MN 55432
PO 66150
SYSTEM DETAILS
0
NOTES:
60
1. ELEVATIONS MAY
VARY DEPENDING ON
GROUND ELEVATION
BUT ARE DRAWN TO
THE BEST OF OUR
ABILITY
2. 2x4 TRUSS 16" OC
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WEST ELEVATION
SETBACKS:
18" FROM RIDGE
18" FROM BOTH SIDES
OF VALLEY
36" FROM EDGE
REVISIONS
LAST:02/20/23 AH
O
O
PROJECT-PAGE TITLE
ELEVATION
DRAWINGS
PAGE NUMBER
Al
ALL
ENERGY
SOLAR I
COMPANY INFORMATION
ALL ENERGY SOLAR, INC
1264 ENERGY LANE
ST PAUL, MN 55108
(800) 620-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
DAVID GAMRADT
6381 MADISON ST NE
FRIDLEY, MN 55432
SNR FLASHING PO 66150
2x4 TRUSS 16" OC
SYSTEM DETAILS
SNAP-N-RACK
MOUNTING HARDWARE:
I I I I I I 1. (40)L-FEET
IF14 I 2. (8) RAIL SPLICES
I I I I I I 3. CLAMPS
I I I I I I I
I I I I (32)MIDCLAMPS
I I I I (8)ENDCLAMPS
I 4. RAIL LENGTHS:
I
I (10)172"RAILS
I
I I I I I 2x4 TRUSS 16"OC
I I I + I
I I I I
I I I
I I I I
I I I I I
I I I I I I
I I I + I I I
I I I + + I I
ARRAY 1
*STRINGING TO BE
DETERMINED ON SITE
REVISIONS
LAST:02/20/23 AH
(18)JA JAM54S31 MODULES
(18)ENPHASE IQ 8M
INVERTER(S)
CIRCUITS:
PROJECT-PAGE TITLE
(2)CIRCUIT(S)OF 9 MICROS RAIL AND
MAX CIRCUIT 15A 20A STRINGING
LENGTH (120/240V) BREAKER BREAKER DIAGRAM
ENPHASE IQ7 12 16 PAGE NUMBER
ENPHASE IQ7+ 9 13 A2
ENPHASE IQ7A 8 11
LABELS LOCATED ON PV PRODUCTION METER, BI- ALL
DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND ENERGY
APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL SOLAR I
LABELS ARE PERMANENT,WEATHERPROOF, AND DURABLE 18"
COMPANY INFORMATION
THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD
POWERLINES. ALL ENERGY SOLAR, INC
1264 ENERGY LANE
DISTANCES: ST PAUL, MN 55108
SOLAR PANELS - INVERTERS: MAX (800) 620-3370
5'
INVERTERS- IQ COMBINER PANEL: 75' MAX I 175' INFO@ALLENERGYSOLAR.COM
IQ COMBINER PANEL-UTILITY AC DISCONNECT: 2'
UTILITY AC DISCONNECT-PV PRODUCTION METER: 2' CLIENT INFORMATION
PV PRODUCTION METER-FUSED AC DISCONNECT: 2' B E N N ETT DR NE
FUSED AC DISCONNECT-BI-DIRECTIONAL METER: 2' DAVID S GAMRADT
BI-DIRECTIONAL METER-MAIN ELECTRIC SERVICE: 5' 6381 MADISON ST NE
FRIDLEY, MN 55432
CALL-OUTS: PO 66150
1: SOLAR PANELS
2: INVERTERS SYSTEM DETAILS
3: IQ COMBINER PANEL NOTES:
4: UTILITY AC DISCONNECT
5: PV PRODUCTION METER 1.(18)ENPHASE IQ 8M
6: FUSED AC DISCONNECT INVERTER(S)=5.85kW AC
7: BI-DIRECTIONAL METER 2.ARRAY 1:
8: MAIN ELECTRIC SERVICE 269'AZIMUTH,20'TILT
ARRAY
RR (18)JA 395W=7.11 kW
1&2
A
W `°
0
Z
H
U)
Z
0 ACCOUNT: 51-0649937-6
SETBACKS PER PREMISE: 303775311
Q I FIRE CODE METER: 13542135
CASE NUMBER: TBD
CAZIMUTH
C N
NOTES:
w
1. LOCATION OF SERVICE PANEL AND ELECTRICAL o
EQUIPMENT ARE SHOWN. FINAL LOCATION MAY -
CHANGE REVISIONS
LAST:02/20/23 AH
2. LOCATION OF SERVICE PANEL AND ADDITIONAL
ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE
3. PV INTERCONNECTION IS A SECONDARY
INTERCONNECTION
4.AC DISCONNECT AND PRODUCTION METER IN PROJECT-PAGE TITLE
READILY ACCCESSIBLE LOCATION WITHIN 10' OF
MAIN SERVICE METER/BI-DIRECTIONAL METER. 24/7
UNESCORTED KEYLESS ACCESS TO BE PROVIDED
FOR UTILITY AC DISCONNECT, PV PRODUCTION SITE MAP
METER,&BI-DIRECTIONAL METER.
5. PV EQUIPMENT SHALL BE INSTALLED IN PAGE NUMBER
ACCORDANCE WITH NEC 690 AND POSTED WITH
APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES ��
PER NEC 705-10, 690-17, &690-64(b)(5).
ALL
ENERGY
(18) JA I SOLAR I
JA COMPANY INFORMATION
W 7.11 k kW
ALL ENERGY SOLAR, INC
MODULE DETAILS: 1264 ENERGY LANE
ST PAUL, MN 55108
(18)JA SOLAR (800) 620-3370
5' MAX JAM54S31-395/MR/1500V INFO@ALLENERGYSOLAR.COM
RATED POWER CLIENT INFORMATION
AT STC: 395W
VMP: 30.84V DAVID S GAMRADT
6381 MADISON ST NE
IMP: 12.81A FRIDLEY, MN 55432
VOC: 36.98V PO 66150
DC (18) ENPHASE ISC: 13.7A SYSTEM DETAILS
IQ 8 INVERTER DETAILS:
120/240V ENPHASE IQ8M-72-2-US SYSTEM SIZE:7.11kW DC
AC SEE LABEL(S) N/A TO UTILITY MAXIMUM POWER:5.85 kW AC
ON FOLLOWING PAGES Rating: 325W
OPERATING VOLTAGE:120/240V
CEC Weighted Efficiency: 97% MAXIMUM CURRENT:24.3A
Max DC Voltage: 58V ACCOUNT:51-0649937-6
Max AC Output Current: 1.35A PREMISE:303775311
Nominal Voltage Range: METER: 13542135
50' MAX 3/4" EMT: 240V/ 211-264V (1-Phase) ` ^ ^ CASE NUMBER:TBD
(4) #10 THWN Nominal Frequency: 60 Hz XCEL ENERGY
(1) #10 GROUND BI-DIRECTIONAL METER
120/240V, 1-PHASE, 3-WIRE NOTES:
SEE LABEL(S)41,42
ON FOLLOWING PAGES 1.DESIGN MEETS NEC CODE
AND SHALL BE INSTALLED/N
FUSED ACCORDANCE WITH NEC 690
AND POSTED WITH APPLICABLE
ENPHASE IQ COMBINER PANEL AC DISCONNECT 2' MAX 1" PVC: 5 WARNINGS, SIGNAGE,AND
120/240V: 125A: 1 PHASE 1 PHASE,60A, 120/240V (2) #6 THWN EXISTING PLAQUES PER NEC705-10, 690-
PLACARD INDICATING ON FOLSEE BLOWING PAGES (1) #6 NEUTRAL CONDUIT 17, &690-64(b) (5)
"NO LOAD TO BE SERVED" 2. SOLAR MODULES,INVERTERS,
SEE LABEL(S)16, 18,24 AND CORRESPONDING
ON FOLLOWING PAGES SOP ESTED.ICAL EQUIPMENT ARE
100A
3.INVERTERS ARE UL 1741
2' MAX 3/4" EMT: 5' LISTED
(2) #10 THWN EXISTING 4.PV INTERCONNECTION IS A
(1) #10 NEUTRAL POINT OF COMMON COUPLING CONDUIT SECONDARY INTERCONNECTION
(1) #10 GROUND LINETAP INSIDE MAIN SERVICE REVISIONS
DISCONNECT VIA POLARIS LUGS. LAST:02/20/23 AH
XCEL ENERGY INSTALLATION IS A SECONDARY 100A
2' MAX 3/4" EMT PRODUCTION METER 2' MAX 3/4" EMT INTERCONNECTION. MAIN
UTILITY (2) #6 THWN 120/240V, 200A WITH (2) #6 THWN
AC DISCONNECT BYPASS
VISIBLE-OPEN TYPE, LOCKABLE, (1) #6 NEUTRAL 1-PHASE, 3-WIRE (1) #6 NEUTRAL
READILY ACCESSIBLE (1) #10 GROUND (1) #10 GROUND
RPA
LINE PROJECT-PAGE TITLE
/PoC
ELECTRICAL
100A RATED BUS LINE DIAGRAM
LOAD
1 PHASE,60A, 120/240V MAIN SERVICE PANEL PAGE NUMBER
SEE LABEL(S)14, 15, 16 16,, 19,20 SEE LABEL(S)21 ON ON FOLLOWING PAGES FOLLOWING PAGES SEE LABEL(S)14, 16
ON FOLLOWING PAGES A4
*DISTANCES NOT TO SCALE
WARNING : PHOTOVLTAICNOTE: LABELS ARE FOR ALL
• • • 6 GENERAL REFERENCE. ENERGY
NOT ALL LABELS ARE USED
POWER
SOURCE
, , FOR EVERY INSTALLATION. COMPANY INFORMATION
5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT ALL ENERGY SOLAR, INC
1264 ENERGY LANE
• 7 ST PAUL, MN 55108
10 (800) 620-3370
RAPID SHUTDOWN
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
FOR SOLAR PV SYSTEM
DAVID S GAMRADT
6381 MADISON ST NE
WARNICFRIDLEY, MN 55432
P ' 13 F A
8: PO 66150
L Aj,,C DISCONNEq- -" TRICAL SHOCK HAZARD SYSTEM DETAILS
r
NOT TOUCH TERMINALS
INALS ON BOTH LINE AND
A WARNING DUAL POWER SOURCE 14 SIDES MAY BE ENERGIZEDN THE OPEN POSITION
SECOND SOURCE IS PHOTOVOLTAIC SYSTEM
15 PHOTOVOLTAIC AC DISC
OPERATINGMAII 4�, #,lFOVOLTAIC MAXIMUM AC
• OPERATING AC VOLTAGE:
SYSI"rir-DISCONNECT
INTERCONNECTION17 20
LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
DISCONNECT MOUNTED,AND COMPLY WITH
SWITCH - NEC 690
SOLAR PV SYSTEM EQUIPPED 35
ACCOUNT:51-0649937-6
PRODUCTION
WITH RAPID SHUTDOWN PREMISE:303775311
AWARNING 36 METER: 13542135
POWER SOURCE OUTPUT CONNECTION. DO NOT 21 CASE NUMBER:TBD
RELOCATE THIS OVERCURRENT DEVICE. REVISIONS
TURN RAPID SHUTDOWN HOUSE
LAST:02120/23 AH
SWITCH TO THE CAUTION 37 METER
"OFF" POSITION TO SOLARELECTRIC
PVPANELS PV SYSTEM CIRCUIT BREAKER IS BACKFED
SHUT DOWN PV SYSTEM
41 PROJECT-PAGE TITLE
AND REDUCE CAUTION : SOLAR ELECTRIC LABELS
SHOCK HAZARD
IN THE ARRAY SYSTEM CONNECTED PAGE NUMBER
42 A5
ALL
15 ENERGY
i SOLAR I
EMERGENCY DISCONNECT CAUTION . COMPANY INFORMATION
ALL ENERGY SOLAR, INC
DISCONNECTSERVICE 1264 ENERGY LANE
MULTIPLE SOURCES OF POWER (800) 620-3370- STPAUL, 8
-3370
INFO@ALLENERGYSOLAR.COM
CLIENT INFORMATION
PV COMBINER PANEL DAVID S GAMRADT
6381 MADISON ST NE
FRIDLEY, MN 55432
INTERCONNECTION 17 UTILITY PV DISCONNECT PO 66150
DISCONNECT PV SERVICE DISCONNECT SYSTEM DETAILS
HOUSE SERVICE DISCONNECT
VOLTAGEMAXIMUM 22
MAXIMUM CIRCUIT CURRENT SOLAR ARRAY N
MAX RATED OUTPUT CURRENT OF
THE CHARGE CONTROLLER
• - •-DC CONVERTER All Energy Solar
www.allenergysolar.com
(800) 620-3370
18
. 24 LABELS ARE WEATHERPROOF,
DURABLE, PERMANENTLY
MOUNTED,AND COMPLY WITH
NEC 690
PVCOMBINER ACCOUNT:51-0649937-6
POWER • PREMISE:303775311
PANELONLYMETER: 13542135
NO LOADSPHOTOVOLTAICCASE NUMBER:TBD
REVISIONS
Operating Voltage : 120/240 LAST:02/20/23 AH
MaximumMaximum Current : 24. 3 Amps
Power :
• •• PROJECT-PAGE TITLE
LABELS 2
PAGE NUMBER
43 A6