Loading...
HomeMy WebLinkAboutfinal garage review 295 rice Creek Blvd LINE OF ROOF EAVE(ABOVE)r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � 0 I I I I / I I WC 1 1 00 1 E I I O I O DEN I OFFICE KITCHEN 00 DINING ROOM WC L BEDROOM 2 ' BONUS ROOM LAUNDRY + MECHANIC ' / o ; APPROVED I JensenD03/06/2023 OWN 1 o I I - - - - - - - - - - - - - - - - - - - - - - - - - - - - «STL beam» «STL beam» CENTER LINE OF TRUSSES/GABLE ROOF 1 STA [verify span condition w/existing trusses to determine if center walls are bearing] UNEX VATED I existing egress wdw. 1 I 1 Smoke detectors in each [deeper light well] I �' I `\ I sleeping room and on each level FAMILY ROOM BEDROOM 1 GARtr r LIVING ROOM BEDROOM 3 BEDROOM 4 i of the house per R314 UP �o°` 1 / remove as needed fornew garage ` I CO detection per R315 2020 I RC. I \ / <VERIFY BEARING+STRUCT. demo.as needed for new WDW+DR ' - - - - 1 - - - - `�i I CONDITION @ WALL/ROOF I i / 1000 gsf (lower level) / 1 demo.existing 1200 gsf (upper level)r v / I stoop+entry - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J - \ I 1 I DENOTES DEMOLITION 1 I I J�`-J :DENOTES DEMOLITION I I I 1: LOWER FLOORAS-BUILT/ DEMOLITION PLAN I 1 1 2: MAIN FLOOR AS-BUILT/ DEMOLITION PLAN 1/4"=1'-0" I garage:270gsf LINE OF ROOF EAVE(ABOVE)- - - - - - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J remove gable roof over south wall N a This plan copy to be at job site 3 A.2 LINE OF ROOF EAVE(ABOVE)r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LINE OF ROOF EAVE(ABOVE) I I I I I � 1 00134.001 >> I 1 � I .. 1 I DEN I OFFICE KITCHEN 00 DINING ROOM WC 2 SD BEDROOM 2 ' 1 c I 1 � I 1 2 8° 71-8m I 5 S 7 1 DOWN A.2 L '� high side(north) 00 r SD/CO r I o Provide min. 1/2" drywall on the garage - side that extends to the roof deck. RAGE NOTE:use 112"min.th.gyp.bd.OR fire protected sheathing S D 35' SETBACK (affected walls shown with dotted line) ------- b 1 i use mineral wool fiber insulation @ walls shown A.2 1 N r r '� y4aT✓y ` \ `-_\ NOTE.ASSURE 20minute.FIRE RATED DOOR i L ' '"" """� BEDROOM 3 BEDROOM 4 � z 14"!1i(@ Provide 20 minute fire -rated doors to °c SD 7F i / %pg EN garage from house. 2 o i 14"!!/� ` *4' ' 1 i V A.2 .2 2'-211 /r 24°o!� �op9 \ 2112 r.o. - r.o. i J n DOWN o DOWN ' 0 I LL C!3 - add blocking b eer CVLs a eeded i eta • r ' 00 74"T✓ to bear load @ existing t members /7L*w s 1 p • r / ��l�%\ o \NCRETF \ 'o9door newin swinging door - - - - _ - _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ LINE OF ROOF EAVE(ABOVE) S�4B - - -= -  - r - - - - - 6 -� E(A E) m NEW GARAGE �s BF1OWFFxst2stoo \ A.2 � o �sTo , Provide 36" entry/front door LLJ r r \ o (concre \ OP \ W v ---.NEW 6'x8'ENTRY DdOR+STOOP 4 W i r A.2 V a (Vlih-6"/clearance from Z framing/siding to ground. p :DENOTES NEW CONSTRUCTION G ` W N c.0 3: SITE PLAN Wo-- ;\ �� 4: MAIN FLOOR PLAN -with added garage/structural + electrical Q 1"=20'-0" ? 2X1g9ar9e \ , 1/4"=1'-0" a door 5 CD AG :600sf o / A.2 4'0' \ _ _zo r low side(south) \ *� r 2023*02920 A 1 location of garage angle relative to existing house � A•2 [rough/framing dimensions] ROOF CONSTRUCTION: 12 TPO or similar membrane roofing 1/2"th. protection board 2'-0" 6 ROOF PITCH -sloped rigid insulation or furring TYP.eave width 3/4"th. boards,(perimeter)+sheathing ---' - - EXISTING HOUSE/CONDITION SHOWN LIGHTER 14"structural members w/R-20 min.insulation 1/2"th.sheathing SEE DETAIL 7 (below) TYP. RUSS BEARING HEIGHT T.0.14"ROOF RAFTERS ------ - r-------- --- • • 1 O <<14 TJI I LVLs 24"o.c. >> oJ� 1 , 1 1 3/4"th.T+G boards @ overhang NEW GARAGE CEILING FRAMING SET 1 1/2" BELOW EXISTING ROOF FRAMING AS SHOWN (NOTE:existing eave and cross >> ' wood siding run horizontal exterior lights 1BD - - .354"th.LP SmartSide Vertical Siding, ' 1 gable over existing garage removed at new garage area) ; - cut from 16"xl6'stock,typical"wrap"over , EO EO EO extended TJI's+LVLs-(quirk miter @ corners) n n ro o A 1 118"th.PSL rim joist board between TJI/LVL ; ` � 2x4 blocking above walls,(typical @ TJI webs) ; n n 1 1 1 1 ' iEs - o oLn ; o - - - o -- I NEW DOOR+WDW. DEC STOOP Yi17 I 7'x18'garage door I " V 1 I o o ' ; �0 I I I N N ' 1 1 Zo r l_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ IT _ _ _ _ - - Min 36" entry door, tempered glass N N V V , 1 L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - v v 1 Overhead garage door shall be ' 1 ' 1: SOUTHERN ELEVATION wind-rated for 114 mph. WALL CONSTRUCTION: ; 3/4"th.cedar or thermally modified wood boards ; 1/4"=1'-0 (rain-screen application w/gaps between boards) 7mm drainage matt,(dark gray/black color) ; 1 water barrier layer ; 1 112"th.sheathing ' 2x6 framing FIFE ' ------ -------------- 1 1/2"th.sheathing44 N TOP OF NEW STOOP 1 DECK _ ^ Provide teated bottom plates + _ MATCH T.O.WALL BEARING HEIGHT r----------------- EXISTING HOUSE/CONDITION SHOWN LIGHTER SECTION @HIGH END ° FINISHED GRADE @STOOP ' (NORTH) °g _ 4N CONC.SLABLl ' = 4"CONC.SLAB SECT 0 N @ LOW EN D , �1 -x x x _x ' (SOUTH) I 1 1 ' o ' t 1 1 ' _ Anchor bolts: min 7" embedded in concrete, ' min 2 per sill, min. 12" from plate ends, min. Go - I v E 6 ' O.C. ,1 E E wood siding run horizontal - � woo iding run horizontal» � � ' N to be at job site plan py - n n n COhI .FTG. 1 5: BUILDING CROSS SECTION, [NEW GARAGE] 6: BUILDING SECTION, [EXISTING CONDITIONS V.I.F.] 3/4"=1'-0" 3/4"=1'-0" 3 4" Yx 6'-8"service door 7'x18'garage door � I I I I I r I- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LF - - - - - - - - -I 2"roof edge flashing 1/2"th.blocking L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -L _ _ _ _ _ _ _ _ _ - Min. 6" clearance from 1 framing/siding to ground. 7mm drainage mat .354"th.LP SmartSide Vertical Siding, 2: WESTERN ELEVATION cut from 1 6"x1 6'stock I 1 112"th.x 4114"x 14"wood trim, I (cut from 2x6 to allow for square edges) Provide engineer report on roof framing/ truss spans. cap flashing to protect siding boards below 3/4"cedar/thermally modified wood siding set over 7mm drainage matt,(rain-screen detail) -- - _-_-- allow for gaps between boards,see elevations to determine vertical or horizontal application CV - M L r) EXISTING HOUSE/CONDITION SHOWN LIGHTER Ltt'7 Z 7: BUILDING SECTION @ WEST EAVE > 1 1/2"=1'-0" LLI J ID 2" IZ — — - — J _ -- - 2"roof edge flashing W 1/2"th. blocking LLI - :- n �=10 wood trim @ S+ N perimeter Min. 6" clearance from V -- - n 10: IMAGE OF ENTRY AREA- n.t.s. framing/siding to ground. W 14"TJI,set beyond wall as shown v - 14" LVL header for garage door, o, attached directly to TJI @ 2x4 water barrier membrane/wrap L1C7 a a top and bottom cord a CV .354"th.LP SmartSide Vertical Siding, Provide tempered glass and 36" entry door �1 cut from 16"06'stock add furring to 14' LVLs to match width of TJI's V wood siding run horizon al water barrier membrane/wrap C 3/4"cedar/thermally modified wood siding C � 1 3/4" .354"th.LP SmartSide Vertical Siding, � L - - - - - - - - - - - - - - - - - - - - - - - - _ set over 7mm drainage matt,(rain-screen detail) Q I cut from 16"x16'stock,typical"wrap"over Q _ I _ _ _ _ _ _ _ _ _ _ - L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ allow for gaps between boards,see elevations i extended TJI's+LVLs-(quirk miter @ corners) L.IJ existing CMU foundation wall+footing to determine vertical or horizontal application Q CM 3: NORTHERN ELEVATION 4: EASTERN ELEVATION 8: BUILDING SECTION @ SOUTH EAVE, (north eave similar- mirrored) 9: BUILDING SECTION @ EXTENDED RAFTER 1/4"=1'-0" 1/4"=1'-0" 1 1/2"=1'-0" 1 112"=1'-0" CM 2023.02.20qD Land Plarunng 370Mississ ppiSt.Nf. Land Surveying Minneapolis 21, Soils Testing ENGINEERING., INC. Minnesola Owl&Municipal S1117se144066 E17JIneenny En9 ineers Survecyors certa,fic to of survey ► AP LOVED D Je enD03/07/2023 Ir°►^ _ t N �. Set 1 ' bdov'g r > W '1 > ;f w e 26' -new 9a 2 — e� p23 .sc ce/e "■�O R 02.20'2 U o .off• Z c.1 P-;:., l hereby cerfiry the*15 is a free and correct represenbf ion o�'a survey e#m boundor;es qr!he abore &sc-; ed land,and #'lfie lorgtion cal(bw/dings,lherean,ordo!/risible p�rcrnvdimenfs,rI'any, fv n or an said land As surveyed by me flns _cby A.0.19 SUBURBAN ENGINEERING, INC. [jYmeers fr Surreyors