HomeMy WebLinkAboutErin Olson 30 panel design plan update.ADDENDUM PLANS TO ORIGINAL APPROVED PLANSpdf ALL ENERGY SOLAR I COMPANY INFORMATION ALL ENERGY SOLAR, INC 1264 ENERGY LANE ST PAUL, MN 55108 (800) 620-3370 INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION ERIN OLSON 97 CRAIG WAY NE FRIDLEY, MN 55432 PO 59927 Panel Type LG 370 # of Panels 30 System Size (kW) 11.10 FLUSH ROOF MOUNT NOTES: 1. (30)ENPHASE IQ7+ INVERTER(S) 2.ARRAY 1: 9°TILT,85°AZIMUTH AZIMUTH REVISIONS ♦ LAST:03/17/23 AK PROJECT-PAGE TITLE COVER PAGE PAGE NUMBER AO ALL CALL-OUTS: DISTANCES ENERGY SOLAR PANELS - INVERTERS: 5' MAX SOLAR I 1: SOLAR PANELS INVERTERS- IQ COMBINER PANEL: 75' MAX 2: INVERTERS IQ COMBINER PANEL-UTILITY AC DISCONNECT: 2' m COMPANY INFORMATION 3: ENPHASE IQ COMBINER PANEL UTILITY AC DISCONNECT-PV PRODUCTION METER: 2' 4: UTILITY AC DISCONNECT PV PRODUCTION METER-FUSED AC DISCONNECT: 2' N ALL ENERGY SOLAR, INC 5: PV PRODUCTION METER FUSED AC DISCONNECT-BI-DIRECTIONAL METER: 2' 1264 ENERGY LANE 6: FUSED AC DISCONNECT BI-DIRECTIONAL METER-MAIN ELECTRIC SERVICE: 5' ST PAUL, MN 55108 7: BI-DIRECTIONAL METER (800) 620-3370 8: MAIN ELECTRIC SERVICE — INFO@ALLENERGYSOLAR.COM m CLIENT INFORMATION <10' ~ ERIN OLSON 97 CRAIG WAY NE 3 4 5 g 7 v FRIDLEY, MN 55432 8 PO 59927 O SYSTEM DETAILS NOTES: 1.(30)ENPHASE IQ7+ INVERTER(S)=8.70kW AC 2.ARRAY 1: 85°AZIMUTH,9°TILT (30)LG 370W= 11.10kW O ARR Y 1 1 2 ACCOUNT: 51-9267230-1 PREMISE: 303470309 METER: 93658502 CASE# 05357136 AZIMUTH NOTES: N 1. LOCATION OF SERVICE PANEL AND ELECTRICAL EQUIPMENT ARE SHOWN. FINAL LOCATION MAY CHANGE 2. LOCATION OF SERVICE PANEL AND ADDITIONAL ELECTRICAL EQUIPMENT NOT DRAWN TO SCALE REVISIONS LAST:03/17/23 AK 3. PV INTERCONNECTION IS A SECONDARY INTERCONNECTION 4.AC DISCONNECT AND PRODUCTION METER IN C RAIG WAY NE ROOF PITCH IS LESS THAN 2112 READILY ACCESSIBLE LOCATION WITHIN 10' OF MAIN PITCH. FIRE SETBACKS NOT SERVICE METER/BI-DIRECTIONAL METER. 24/7 REQUIRED. UNESCORTED KEYLESS ACCESS TO BE PROVIDED PROJECT-PAGE TITLE FOR UTILITY AC DISCONNECT, PV PRODUCTION METER,&BI-DIRECTIONAL METER. 5. PV EQUIPMENT SHALL BE INSTALLED IN LABELS LOCATED ON PV PRODUCTION METER, BI- SITE MAP ACCORDANCE WITH NEC 690 AND POSTED WITH DIRECTIONAL METER, AC DISCONNECT(S), INVERTER(S), AND APPLICABLE WARNINGS, SIGNAGE, AND PLAQUES APPROPRIATE LABELS ON MAIN ELECTRIC SERVICE. ALL PER NEC 705-10, 690-17, &690-64(b)(5). LABELS ARE PERMANENT, WEATHERPROOF, AND DURABLE PAGE NUMBER 6. CIRCUITS: THERE ARE NO CLEARANCE ISSUES DUE TO OVERHEAD POWERLINES. (3)CIRCUIT(S)OF 10 (20AMPS EACH) Al SOUTH ELEVATION ALL i SOLAR I COMPANY INFORMATION ALL ENERGY SOLAR, INC 1264 ENERGY LANE so'S., ST PAUL, MN 55108 (800) 620-3370 32'2" INFO@ALLENERGYSOLAR.COM 19,S„ CLIENT INFORMATION ERIN OLSON 97 CRAIG WAY NE FRIDLEY, MN 55432 PO 59927 SYSTEM DETAILS N NOTES: 60 1. ELEVATIONS MAY VARY DEPENDING ON GROUND ELEVATION BUT ARE DRAWN TO THE BEST OF OUR ABILITY 2. 2X6 RAFTERS @ 16" OC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EAST ELEVATION 32' 4' 27'9" REVISIONS LAST:03/17/23 AK PROJECT-PAGE TITLE 0 b ELEVATION DRAWINGS PAGE NUMBER A2 ALL ENERGY i SOLAR I COMPANY INFORMATION I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ALL ENERGY SOLAR, INC I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1264 ENERGY LANE I I I I I I I I I I I I I I I I I ST PAUL, MN 55108 I I I I I I I I I I I I I I (800) 620-3370 I I I I I I I I I INFO@ALLENERGYSOLAR.COM I I I I I I I I I I I I I I I I I I I I I El I I I I I I CLIENT INFORMATION I I I I I I I I I I I I I I I I I I I I I ERIN OLSON I I I I I I I I I 97 CRAIG WAY NE FRIDLEY, MN 55432 I I I I I I I I I I I I I I I I PO 59927 IIIII IIIII SYSTEM DETAILS R RA 11 I I I I I I I SNAP-N-RACK I I I I I I I I I I IfilI I -� I -- MOUNTING HARDWARE: I I I I I I I I I I I I I I 1. (78)L-FEET I I I 2. (4) RAIL SPLICES - -- -- -- 3. CLAMPS I I I i (42)MIDCLAMPS I , (36)ENDCLAMPS I ® I I I I I I I I 4. RAIL LENGTHS: I I - (16)172"RAILS I I I I I I I I I I I I I I I I I I _ 2X6 RAFTERS @ 16"OC I I *STRINGING TO BE I I I I DETERMINED ON SITE AZIMUTH i i l l l l l l i i l l l l l l I I I I I I I - I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ROOF PITCH IS LESS THAN 2112 PITCH. FIRE SETBACKS NOT i i i i i i i i REVISIONS REQUIRED. I I I I I I I I LAST:03/17/23 AK I I I I I I I I I I I I I I I I (30)LG LG370N1K-A6 MODULES I I I I I I I I I I I I I I I I (30)ENPHASE IQ7+INVERTER(S) � I I I I CIRCUITS: PROJECT-PAGE TITLE (3)CIRCUIT(S)OF 10 MICROS RAIL AND MAX I I (1R 20 2I LENGTH 40V) BREAKER BREAKER STRINGING ENPHASE IQ7 12 16 DIAGRAM PAGE NUMBER ENPHASE IQ7+ 9 13 68.51 x 41 .011 x 1 .57" ENPHASE IQ7A 8 11 A3 ALL MODULE DETAILS: ENERGY (30) LG LG370N1 K-A6 (30) LG 11.10kW LG370N1 K-A6 COMPANY INFORMATION RATED POWER ALL ENERGY SOLAR, INC AT STC: 370W 1264 ENERGY LANE ST PAUL, MN 55108 VMP: 35.50V (800) 620-3370 IMP: 10.43A INFO@ALLENERGYSOLAR.COM 5' MAX VOC: 41.60V CLIENT INFORMATION ISC: 10.96A ERIN O INVERTER DETAILS: 97 CRAIG WAY NE ENPHASE IQ7PLUS-72-2-US FRIDLEY, MN 55432 Rating: 290 W PO 59927 CEC Weighted Efficiency: 97 % SYSTEM DETAILS (30) ENPHASE Max DC Voltage: 60.V V DC IQ7+ SYSTEM SIZE:11.10kW DC 120/240V Max AC Output Current: 1.21 A MAXIMUM POWER:8.70 kW AC AC (3) CIRCUIT(S) OF 10(20A EA) Nominal Voltage Range: OPERATING VOLTAGE:120/240V 240V/ 211-264V (1-Phase) MAXIMUM CURRENT:36.30A Nominal Frequency: 60 Hz ACCOUNT:51-9267230-1 TO UTILITY PREMISE:303470309 75' MAX 3/4" EMT: METER:93658502 (6) #10 THWN CASE#05357136 (1) #10 GROUND XCEL ENERGY BI-DIRECTIONAL METER 120/240V, 1-PHASE, 3-WIRE NOTES: SEE LABEL(S)41,42 ON FOLLOWING PAGES 1.DESIGN MEETS NEC CODE ENPHASE IQ COMBINER PANEL AND SHALL BE INSTALLED IN 120/240V 125A 1 PHASE ACCORDANCE WITH NEC 690 PLACARD INDICATING AND POSTED WITH APPLICABLE 2' MAX 1" PVC' �/�/� WARNINGS, SIGNAGE,AND "NO LOAD TO BE SERVED" SEE LABEL(S)16, 18,24 (2) #6 THWN v v ` 17,A&690- 4Eb NEC 705-10, 690- ON FOLLOWING PAGES (1) #6 NEUTRAL 2. SOLAR MODULES,INVERTERS, AND CORRESPONDING 2' MAX 3/4" EMT: ELECTRICAL EQUIPMENT ARE (2) #8 THWN LISTED. (1) #10 NEUTRAL LINETAP INSIDE MILBANK 200A 3.INVERTERS ARE UL 1741 (1) #10 GROUND W/ BYPASS METER SOCKET VIA LISTED MILBANK UL LISTED K4977 TAP 2, 4.PV INTERCONNECTION IS A CONNECTOR, SECONDARY INTERCONNECTION RPA Poc EXISTING REVISIONS LAST:03/17/23 AK XCEL ENERGY 200A 2' MAX 3/4" EMT PRODUCTION METER 2' MAX 3/4" EMT MAIN UTILITY (2) #6 THWN 120/240V, 200A WITH (2) #6 THWN AC DISCONNECT BYPASS (1) #6 NEUTRAL 1-PHASE, 3-WIRE (1) #6 NEUTRAL FUSED VISIBLE-OPEN TYPE,LOCKABLE, (1) #10 GROUND (1) #10 GROUND AC DISCONNECT READILY ACCESSIBLE LINE PROJECT-PAGE TITLE My ELECTRICAL 200A RATED BUS LINE DIAGRAM LOAD 1 PHASE,60A, 120/240V 1 PHASE,60A, 120/240V GE PAGE NUMBER SEE LABEL(S)10, 14, 15, 16,20,35 SEE LABEL(S)21 ON SEE LABEL(S) 10, 16, 18 LOAD PANEL ON FOLLOWING PAGES FOLLOWING PAGES ON FOLLOWING PAGES SEE LABEL(S) 18 ON FOLLOWING PAGES A4 *DISTANCES NOT TO SCALE WARNING : PHOTOVLTAICNOTE: LABELS ARE FOR ALL • • • 6 GENERAL REFERENCE. ENERGY NOT ALL LABELS ARE USED POWER SOURCE , , FOR EVERY INSTALLATION. COMPANY INFORMATION 5: EXPOSED DC CONDUIT, JUNCTION BOXES, ECT ALL ENERGY SOLAR, INC 1264 ENERGY LANE • 7 ST PAUL, MN 55108 10 (800) 620-3370 RAPID SHUTDOWN INFO@ALLENERGYSOLAR.COM CLIENT INFORMATION FOR SOLAR PV SYSTEM ERIN OLSON 97 CRAIG WAY NE WARNIC FRIDLEY, MN 55432 P ' 13 A 8: PO 59927 ELECTRICAL SHOCK HAZARD SYSTEM DETAILS • INVERTER(S):N/A L Aj,,C DO NOT TOUCH TERMINALS AC DISCONNECT(S):10, 16, 18 TERMINALS ON BOTH LINE AND UTILITY AC A WARNING DUAL POWER SOURCE 14 LOAD SIDES MAY BE ENERGIZED DISCONNECT:10, 14, 15, 16,20, IN THE OPEN POSITION 35 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM PV PRODUCTION METER:21 MAIN ELECTRICAL SERVICE:18 15 PHOTOVOLTAIC AC DISCONNECT BI-DIRECTIONAL METER:41,42 MAIN7�, t', FOVOLTAIC OPERATING 16 IQ COMBINER PANEL:16, 18,24 SYSI"rir-I DISCONNECT L NOMINAL OPERATING AC VOLTAGE: INTERCONNECTION 17 20 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY DISCONNECT MOUNTED,AND COMPLY WITH SWITCH ' NEC 690 SOLAR PV SYSTEM EQUIPPED 35 ACCOUNT:51-9267230-1 PRODUCTION WITH RAPID SHUTDOWN PREMISE:303470309 AWARNING 36 METER:93658502 POWER SOURCE OUTPUT CONNECTION. DO NOT 21 CASE#05357136 RELOCATE THIS OVERCURRENT DEVICE. REVISIONS TURN RAPID SHUTDOWN HOUSE LAST:03117/23 AK SWITCH TO THE CAUTION 37 METER "OFF" POSITION TO SOLARELECTRIC PVPANELS PV SYSTEM CIRCUIT BREAKER IS BACKFED SHUT DOWN PV SYSTEM 41 PROJECT-PAGE TITLE AND REDUCE CAUTION : SOLAR ELECTRIC LABELS SHOCK HAZARD IN THE ARRAY SYSTEM CONNECTED PAGE NUMBER 42 A5 ALL 15 ENERGY i SOLAR I EMERGENCY DISCONNECT CAUTION . COMPANY INFORMATION ALL ENERGY SOLAR, INC DISCONNECTSERVICE 1264 ENERGY LANE MULTIPLE SOURCES OF POWER (800) 620-3370. STPAUL, 8 -3370 INFO@ALLENERGYSOLAR.COM PV COMBINER PANEL CLIENT INFORMATION UTILITY PV DISCONNECT ERIN OLSON PV SERVICE DISCONNECT 97 CRAIG WAY NE HOUSE SERVICE DISCONNECT SOLAR ARRAY FRIDLEY, MN 55432 INTERC • • 17 (BASEMENT) PO 59927 SYSTEM DETAILS DISCONNECT INVERTER(S):N/A AC DISCONNECT(S):10, 16, 18 ° UTILITY AC DISCONNECT:10, 14, 15, 16,20, 35 MAXIMUM VOLTAGE 22 PV PRODUCTION MAXIMUM CIRCUIT CURRENT N METER:21 MAIN ELECTRICAL SERVICE:18 BI-DIRECTIONAL METER:41,42 MAX RATED • • IQ COMBINER PANEL:16, 18,24 THE CHARGE CONTROLLER • ' •-DC CONVERTER All Energy Solar www.allenergysolar.com (800) 620-3370 18 . 24 LABELS ARE WEATHERPROOF, DURABLE, PERMANENTLY MOUNTED,AND COMPLY WITH NEC 690 PVCOMBINER ACCOUNT:51-9267230-1 POWER • PREMISE:303470309 PANELONLYMETER:93658502 NO LOADS PHOTOVOLTAIC CIRCUIT CASE#05357136 REVISIONS Operating Voltage : 120/240 LAST:03/17/23 AK Maximum - . • Amps Maximum Power : 8 . 70 KW PROJECT-PAGE TITLE LABELS 2 PAGE NUMBER 43 A6