HomeMy WebLinkAboutPeterson spec sheet L 1A A0US Deck Specifications
CONSTRUCTION Cory Maxon 1-800-873-1451
1 Footings: Conrete Footing with Sonotube:
Footing Diameter Depth Diameter
Or
PierTech helical piles 5' 12'
Z Support Posts: 6x6 Treated withstand Ott KDAI
3 Beams: Double 2x10 flush beam KDAT
4 Joists 2x10 Joists 12"O.C. KDAT
5 Lumber5pecles #1 Southern Yellow Pine KDAI
6 Decking 5/4 x 6 Timbertech
7 Helghtotdeckottground
8 Height of Guard Rail/Hand Rail 36"
9 Railing Spindle Spacing
10 Size of Deck 10 x9 15
x
Sq/ft 150
11 Distance to Property Lines:See Attached Site Plan
Side 1: 31'
Side 2: 43'
Rear: 74'
Front: 30'
Other: Exist
12 Connections:
Ledger to house: 1-3201-2 every 10"keep back from ends/splice, 1.785"from bottom/top. 1.5"wi
Fasteners: Support Posts to Footings: Simpson-Strong-Tie Metal Stand Off-ABA44Z
grk@grkfasteners.com Support Posts to Deck: GRK-Fasteners-RSS#5/16"x 4"
www.strongtie.com Joist to Ledger and Beam: 2x12 Joist Hangers with Galvanized Nails
Lateral Connection: Simpson DTT1Z Deck Tension Tie
13 7.75" rise/10" run stairs