HomeMy WebLinkAboutFinal Deck Review 710 67th Ave APPROVED
Jensen D04/03/2023
Peterson Deck Plan BUILD GUARDS TO
WITHSTAND MIN.
200LB LATERAL
FORCE
Scope of Work:
2x10 Treated Ledger with Rino PVC Flashing
7'-6" New Footings: 12" PierTech Screw Pile to Spec
6x6 Treated Support Posts with Stand Off
1 , 24" 2x10 KDAT (Southern Yellow Pine)Joists 12"O.C.Joist Hangers
Double 2x10 flush beam
Staircase framed with 2x12 KDAT at 9"centers
New Decking will be TimberTech Prime Plus Sea Salt Fray installed with hidden fasteners
"Picture Frame"deck board with square edge will match decking
Deck Skirting with 12"skirt board will match decking
13'-6" Railing Post will be 2" Black Sand and FE26 welded railing
Add City Permit
PROVIDE STAIRWAY ILLUMINATION
MAX RAIL SPACING 4"
MIN GUARD HEIGHT;
36"
MAX STAIR RISE; 7 3/4"
MIN TREAD ; 10"
Provide deck attachment for lateral support, min (2)
Per section R507.9.2 2020 1 RC.