HomeMy WebLinkAboutrc-report-sun-room-addition-apr-19-23 CGenerated by REScheck-Web Software
�(J Compliance Certificate
Project Sun Room Addition
Energy Code: 2009 IECC
Location: Fridley, Minnesota
Construction Type: Single-family
Project Type: Addition
Orientation: Bldg. faces 270 deg. from North
Climate Zone: 6 (7391 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
5250 Buchanan Street
Fridley, MN 55432
Compliance: Passes using UA trade-off
Compliance: 9.1%Better Than Code Maximum UA: 44 Your UA: 40
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Gross Area Cavity Cont. Prop. Req. Prop. Req.
Perimeter
Ceiling: Cathedral Ceiling 144 38.0 6.0 0.023 0.026 3 4
Wall: Wood Frame, 16" o.c. 288 19.0 0.0 0.060 0.057 13 13
Orientation: Unspecified
Door: Solid Door(under 50% glazing) 17 0.350 0.350 6 6
Orientation: Unspecified
Window:Vinyl Frame 47 0.300 0.350 14 16
Orientation: Unspecified
Floor: All-Wood JoistfFruss 144 30.0 6.0 0.027 0.033 4 5
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2009 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Title: Sun Room Addition Report date: 04/19/23
Data filename: Page 1 of 1