Loading...
HomeMy WebLinkAboutFinal Remodel Review 295 Rice Creek LINE OF ROOF EAVE(ABOVE),- r - - - - - - - - - - - - - - - - - - - .Ne I demo.as needed for new WDW demo.as needed for new WDW �J `a5 I - ° NEW ELECTRICAL I °' PANEL LOCATIOil. o utility sink I o _ 00 remove cabinets+fixtures = <DEMO WALL � \y� -o 0 C0 DEN I OFFIL� e} KITCHEN' DINING ROOM BEDROOM 2 MECHANICAL ' I � remove cabinets,soffits, c 0 +appliances <> �J�a `rea I OWN .� ^ � 5 -- c, - - - - - - - - - - - - - - - - - - - - - - - - - - - N ( «STL beam» «STL beam» i - - �� - - N - - - - - , CENTER LINE OF TRUSSES/GABLE ROOF I [verify span condition w/existing trusses to determine if center walls are bearing] 40 o I UNEXCAVATED CM �CU I I o <existing egress wdw. [deeper light well] I ' i Li FAMILY ROOM BEDROOM I I GARAGr LIVING ROOM BEDROOM 3 BEDROOM 4 remove as needed for new garage lea I Z4 I e I I demo.as needed for new WDW demo.a eded for new WDW de as needed for new WDW <VERIFY BEARING+STRUCT. J I l CONDITION @ WALL/ROOF 1000 gsf (lower level) 1200 gsf (upper level) � J demo.existing stoop+entry - - - - - - - - - -APPROVED Jensen D04/26/2023 I I SEPARATE PERMITS FOR: ELECT, PLUMB. MECH. DENOTES NEW CONSTRUCTION I garage:270 gsf I This plan copy to be at job site DENOTES DEMOLITION LINE OF ROOF EAVE(ABOVE) - - - ! _J � :DENOTES DEMOLITION 1 : LOWER FLOOR AS-BUILT I DEMOLITION PLAN 2: MAIN FLOOR AS-BUILT/ DEMOLITION PLAN 1l4'=1'-0' 1/4'=1'-0' Tempered glass per R308 Size all headers ar a} --; - - - - - - - - - - - - - - - - - - - - - - - LINE OF ROOF EAVE(ABOVE) LINE OF ROOF EAVE(ABOVE) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - s re purposed windows }� �J�� 3 W.3 Op i fixed csmt. - - - - - - - - - - - - - - - - - 3 — — — — — — — — — — — — — — — — — — aMin 15 inches to each side o 9 W.C., Min 24 inches in front of fixture. 1 F.1 00 >> I (tile) 7DR If stair way to be replaced must meet currant code for rise/tread, landings, width and headroom perR311 .7.1 2020 IRC R.I timer;' rgency escape openings per R310 2020 IRC — — — — — — — - - - - - - SD range range ood �0 SD/CO - - - - - - - - - - - - - - - — — — — — — — — — — — — S+ �� — I ? I I max +GPCFM - - n - - I hood/tan c N / C (wood) I D 0 SETBACK / ;0 = / Provide proper sized framing nails Z / I 3'-8" RN C.4 > / I - 32"R/F - LL1 —. DOWN C.3 INING LIVI / 2 rPn r,P`%E / (concrete) R �� wooIi0\ L z LI t *4' O motonnssensor (tile) 0 o Q - DOWN DOWN F., R.2 CID I Y 3► L U / Smoke detectors in each o°' C= - - - - - - - - - - - - - - - - - - - . - - - - - - - - - - - - - - - - .`c- - - - - - - - - - - -I LINE OF ROOF EAVE(ABOVE) C� / sleeping room and on each level �� Q. W / r i of the house per R314 FIXTURE: QTY: NOTES: V C 1 3 ceiling mounted decorative @ entry-TBD(on motion sensor) NEW LOCATION FpR ENTRY DOOR Hard wire main level C.2 3 ceiling mounted decorative @kitchen soffit-TBD LAI) / / - _ +STOOP C.3 4 ceiling mounted decorative @ kitchen island-TBD O% C.4 1 ceiling mounted decorative pendant @ dining-TBD �N CO detection per R315 F.1 1 exhaust fan from AERO-PURE DESIGNER SERIES-TBD Z 2020 IRC. F.2 1 52"+/ceilin fan w/integral light TBD O R.1 2 3"recessed wet rated lights,(HALOH3linevolta eorsimilar)-TBD R.2 2 3"recessed wall washing/directional lights,(HALO H3 line voltage orsimilar)-TBD C= C= L / DENOTES EXISTING"AS-BUILT"CONDITIONS W.1 1 wall mounted wet rated decorative fixture @bedroom patio door-TBD Q \ / + DENOTES NEW CONSTRUCTION/CONDITIONS med.cab 1 KOHLER,K-81146-SLE,wall mounted medicine cabinet w/LED side lights Z / NOTE:garge scope was permitted previously O_ � / Q N NOTE 9arge sco- 3: SITE PLAN 24 pewasper _ / 4: DESIGN PLAN - MAIN LEVEL COMPLETE w/ electrical CDZ 1"=20' 0" 0 mrttPdpreviousl _ _ /l 1/4"=1'-0' y � � ARAG . E.600s f c l A. 1 5'-6" *location of garage angle relative to existing house 2023.04.20 [rough/framing dimensions]