Loading...
HomeMy WebLinkAboutFinal Building remodel review 7579 Able Street SUBJECT 1�.� Dw�-�I�Y"a 1 li� a SHEET NO OF 3 o O y a yam;T a PROJECT NO. 75+1 - 7.51jj--J AL1:r BY l_Ptr- DATE 4- 13-2"3 CHECKED BY: APPROVED SEPARATE PERMITS FOR: ELECT, PLUMB. MECH. JensenD04/28/2023 Co 4- 1 le'-a' Arm. .��.�.r-� w a l 1 is -Z-7-1 O -Z. • �C'.b1t rr. i A -,eet m i w CO A oVse.. grs, --44 Provide proper sized supply and CO detection per R315 return air ducts to rooms 2020 I RC. This plan copy to be at job site Smoke detectors in each sleeping room and on each level of the house per R314 F3 r �9� bvar� D el�a►: 1 C. I It brac-Q.S W O , C . B GQ'rr. SkR-,&-4 v o Lk C Y•is`C z.>c4 p s, w a l rem Dvad � k-cL4. 4y, e-c. w q�L r�rnl7v� sego A SUBJECT l h e- �`A�e �" `' 4u SHEET NO '1 OF 3 goo-( F u-a m t r- PROJECT NO. 7517 � A-G DATE CHECKED BY: N-ew for e�c fie 2- N Z, SSA c, --- - ----1 — 1� N ew C.e,► (i i�� S�►T N o 1� �e.i .6 f p v e.- `a p d� i�1C>c.L � w a l , 5 ►•-��:o y, Ct'�' 3� brq. �r -! f moots-►- ► , �r Ct Wall re ►"Ove-j I � SUBJEC �- uus. I t SHEET NO 3 OF O/ r PROJECT NO.IL;T L,rL w •e L 1 re n,a v,.1 BY L-AG DATE 4 CHECKED BY: L iv �-b d i' ��^ot w.i i s CZ r Gt ��1� r' S 1 S o•n . svf,por4.d t*4- w = I C> z 2 o. -t5�1 "15�9 Abl , M - �to ,� il-i - 3JS 47r 12b 8 Tll z-zY' 1-L- L(."7 K, L �- Sic Irv �c /`� xt�.3 _ b • 3S ; r� xz- r •�� os toPs; ok 4 = D, S 3 ; ►,. z -�z 3 n o lam. u5IL E per engineered report The Dwelling Place April 14, 2023 Fridley, MN APPROVED Attn: Steve Chell, JensenD04/28/2023 Re: House Roof framing 7577 & 7579 Able Street NE, Fridley, MN Steve; I made a visual inspection on April 12, 2023 to verify the roof framing for the residence at 7527 & 7529 Able Street and have applied that existing roof framing to the residence at 7577 & 7579 Able Street. The existing roof framing for both residences is for a 4:12 sloped rafter system consisting of 2x4 rafters and 2x4 ceiling joists all at 16" o.c., diagonal bracing is a 2x4 at 32" o.c. The purpose of the inspection is to verify a way of supporting the ceiling once the first floor non- load bearing interior wall between the kitchen and the living room is removed. The wall in question once removed will make the room almost 22' in width for the residences use. The general procedure for the renovation, is to be able to support the existing ceiling framing. Items to be done; support the ceiling area being modified, remove the non-load bearing interior wall, cut out a 4'+/-width of the existing sheet rock ceiling for accessing the attic framing, adding a support beam (2 — 2x10's) above and perpendicular to the existing ceiling joists, tie the beam and joists together with 2 Simpson H2.5A clips and tying all the framing back together. Keep in mind that, the construction sequence and the means and method will be up to the contractor. Enclosed you will find three pages. • Page 1 of 3 — roof plan and section • Page 2 of 3 - construction details • Page 3 of 3 - Calculation of beam Respectfully Submitted, Lee A Granquist, P.E. MN 13935