HomeMy WebLinkAboutFinal solar Review 1475 Creek Park Lane GENERAL NOTES AERIAL VIEW CODE AND STANDARDS +# / 1.ALL WORK SHALL COMPLY WITH 2O20 NATIONAL ELECTRIC CODE(NEC),2020 MINNESOTA BUILDING CODE,2020 + - BLUE RAVE MINNESOTA RESIDENTIAL CODE(MRC),2018 INTERNATIONAL RESIDENTIAL CODE(IRC),2018 INTERNATIONAL S PLUMBING CODE(IPC),AND ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. 2.DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. - d fb `• r ` 1403 N. Research Way ir- SITE NOTES/OSHA REGULATION n I ► ", E � Orem, UT 84097 1.A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 800.377.4480 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM. f . 4 WWW.BLUERAVENSOLAR.COM 3.THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. ,i r " 4.ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND ' !� z 1 •' CONFIDENTIAL-THE INFORMATION THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SHALL SERVE TO PROTECT �► tA HEREIN CONTAINED SHALL NOT BE THE BUILDING OR STRUCTURE. R "M - M` 0 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR j t A- SHALL IT BE DISCLOSED IN WHOLE OR SOLAR CONTRACTOR +• * IN PART TO OTHERS OUTSIDE 1.MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. ry • �• RECIPIENTS ORGANIZATION,EXCEPT 2.IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING LUG HOLES PER i} 1 '+ IN CONNECTION WITH THE SALE AND THE MANUFACTURER'S INSTALLATION REQUIREMENTS. .�. USE OF THE RESPECTIVE EQUIPMENT, 3.AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF y r WITHOUT THE WRITTEN PERMISSION STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. 1 OF BLUE RAVEN SOLAR LLC. i 4.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO k F + LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. yr�{'f 5.CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND SEALED WITH A NAB C E P SUITABLE SEALING COMPOUND. 1 6.DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. ' { i• CERTIFIED 7.ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/SUITABLE WIRING CLIPS. 8.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC UNLESS NOT �• PV INSTALLATION AVAILABLE. 1 9.ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS,AC t •R PROFESSIONAL PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT COMBINERS,AND +a r y 4 _ Scott Gurney CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND +w � � #PV-011719-015866 LISTED FOR THE APPLICATION PER NEC 690A(B). r 10.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. F 1 - .L' } + ' CONTRACTOR: 11.TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED) * BRS FIELD OPS IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. + M 800-377-4480 EQUIPMENT LOCATIONS -� - Sealed For 1.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPME T WILL BE PROVIDED AS PER SECTION NEC 110.26. _ • % -r Existing Roof & 2.EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS n I SPECIFIED BY NEC 690.31(A)AND NEC TABLE 310.15(B). s Attachment O. y 3.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC M U APPLICABLE CODES. / } Z t Q Q 4.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 0 ♦ `�lillll��/' PROJECT INFORMATION: ':F Q z a) (0 10EN D Y NUMBER OF STORIES: 1 - - *e 0 Q N N CONDUIT RUN: Interior , "'�` '` - ENG E - ZW_ 0- (_n fn ECOBEE QTY: 0 % - 52823 - '" � LIGHT BULB QTY: 0 =•A� Y J PV METER: Not Required 2 ••'••. .•••5�; W a UJ O W W DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX •,F oF-Mi�yN��; 0 LU w D_ ROOF TYPE (1) INFORMATION: `r/l l l l l i`' � W >_ >_ O WIND SPEED: 115 mph CONSTRUCTION -V-B PV1 -COVER SHEET F_ Z U Z ROOF TYPE: Comp Shingle GROUND SNOW LOAD: 50 Ib/ft2 ZONING: RESIDENTIAL PV2-SITE PLAN � Z Lo FRAMING TYPE: Manufactured Truss WIND EXPOSURE FACTOR: C PV3- ROOF PLAN Q It z U U SHEATHING TYPE: OSB U H Q 0SEISMIC DESIGN CATEGORY: B PV4-STRUCTURAL 5/25/23 ATTACHMENT: SFM Infinity Flashkit PV5- ELECTRICAL 3-LINE DIAGRAM RACKING: Unirac SFM Infinity @ 24" OC Portrait/48" OC Landscape DRAWING BY: NUMBER OF ATTACHMENTS: 43 SCOPE OF WORK PV6- ELECTRICAL CALCULATIONS PV7-WARNING LABELS AND LOCATIONS Brendan Fillmore ROOF TYPE (2) INFORMATION (IF APPLICABLE): INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM AND ANY PV8- PLACARD PLOT DATE: *SEEPV4.2 NECESSARY ADDITIONAL WORK NEEDED FOR INSTALLATION. (ALL OTHER SHEETS AS REQUIRED) SS- PRODUCT SPEC. SHEETS May 24, 2023 Digitally signed SYSTEM TO BE INSTALLED INFORMATION: UTILITY COMPANY: by John A. PROJECT NUMBER y y p p p Energy Calvert 780719 DC SYSTEM SIZE: 6.4 kW DC Ihereb certify that this lan,s ecificationorre report Xcel Ener MN was prepared by me or under my direct supervision and SHEET NAME: AC SYSTEM SIZE: 4.64 kW AC that I am a duly Licensed Professional Engineer under Date: 2023.05.25 the laws of the State of Minnesota.John A.Calvert, MODULE TYPE: (16) URE FBM400MFG-BB COVER SHEET License No.52823 Expiration Date:30-June-2024 PERMIT ISSUER: INVERTER TYPE: Enphase IQ8PLUS-72-2-US 17:09:17 -06'00' MONITORING: Enphase IQ Combiner 4 X-IQ-AM1-240-4 City of Fridley REVISION: PAGE NUMBER: 0 1 PV1 PV SYSTEM SPECIFICATIONS — - LEGEND — TOTAL NUMBER OF MODULES: 16 JUNCTION BOX MODULE MAKE AND MODEL: URE FBM40OMFG-BB I MODULE WATTAGE: 400W DC ' � BLUE RAVEN r APPROVED I � UTILITY METER INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US I 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) JensenD06/05/2023 I FM SP MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC I 800.377.4480 INVERTER NOMINAL VOLTAGE: 240V AC AC DISCONNECT WWW.BLUERAVENSOLAR.COM INVERTER WATTAGE: 290W AC I I CONFIDENTIAL-THE INFORMATION SEPARATE PERMITS FOR: ELECT HEREIN SED CONTAINEDNEEFITOFNOTBE I NE CB COMBINER BOX UEXCEPT BLUE RA EN OL A NOR I EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR LOAD CENTER IN PART TO OTHERS OUTSIDE I I LC RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, I SUB WITHOUT THE WRITTEN PERMISSION SUBPANEL IOF BLUE RAVEN SOLAR LLC. I PV PV METER rNACEP I ITS TRANSFER SWITCH CERTIFIED Io PV INSTALLATION I ESS SUNPOWER ESS PROFESSIONAL IScott Gurney I #PV-011719-015866 I ® 19 HUB SUNPOWER HUB+ � CONTRACTOR: I RPO REMOTE POWER OFF BRS FIELD OPS I800-377-4480 I FIRE SETBACK I I ® 0 TRENCHING N Setback at ridge 2020 I z LO >a> o IRC ge p er � � I i PROPERTY LINE Q � Y C > 08 ® SCALE: 1/16" = V-0" z I I Sealed For LL Q 2 N N Existing Roof & z w a U) Fn Fn I I Attachment Only W Z) w O 2 2 LU C� w LU wa � � I � � � w U) U) .At Q ~ z UU = � I _ iCEN D _ � DRAWING BY: E" Brendan Fillmore •; 52823 AQ PLOT DATE: \ 5/25/23 T c,0� \ '�F•OF May 24, 2023 FRONT OF HOME 30' 1475 CREEK PARK LN q ST PROJECT NUMBER: °F RTtiC R°SS 780719 of TF URS ST F R FT I hereby certify that this plan,specification or report SHEET NAME was prepared by me or under my direct supervision and MF that I am a duly Licensed Professional Engineer under SITE PLAN \ the laws of the State of Minnesota.John A.Calvert, \ License No.52823 Expiration Date:30-June-2024 REVISION: PAGE NUMBER: NO CLEARANCE ISSUES EXIST FOR OVERHEAD OR UNDERGROUND SERVICE LINES. \ 0 P 2 PV SYSTEM SPECIFICATIONS LEGEND TOTAL NUMBER OF MODULES: 16 JUNCTION BOX MODULE MAKE AND MODEL: URE FBM40OMFG-BB MODULE WATTAGE: 40OW DC UTILITY METER BLUE RAVEN INVERTER MAKE AND MODEL: Enphase IQ8PLUS-72-2-US 1403 N. Research Way INVERTER TYPE: Microinverter(1 Inverter per PV Module) FM—SPI MAIN SERVICE PANEL Orem, UT 84097 INVERTER CURRENT OUTPUT: 1.21A AC 800.377.4480 INVERTER NOMINAL VOLTAGE: 240V AC AC DISCONNECT WWW.BLUERAVENSOLAR.COM INVERTER WATTAGE: 290W AC CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE CB COMBINER BOX USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR LOAD CENTER IN PART TO OTHERS OUTSIDE LC RECIPIENTS ORGANIZATION,EXCEPT 3' IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SUB SUBPANEL WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. PV PV METER NABCEP ❑ TS TRANSFER SWITCH I CERTIFIED O PV INSTALLATION MP2 ESS SUNPOWER ESS PROFESSIONAL #OF MODULES: 6 ® 3' Scott Gurney AZIMUTH: 248 0 0 #PV-011719-015866 PITCH: 23 HUB SUNPOWER HUB+ CONTRACTOR: TSRF: 82% ® BRS FIELD OPS AREA: 746 ft.2 T-6" RPO REMOTE POWER OFF 800-377-4480 • FIRE SETBACK O j TRENCHING -t Q U Z U-) > 0 • z i PROPERTY LINE 0 LO 31 z SCALE: 3/32" = V-0" a Z ° CO POINT OF INTERCONNECTION J (D It cfl UNDERGROUND SERVICE LINE 0 z 3' 0 N_ N_ 2'-6" Ms z 0 Z w_ 0- (_n U) U) wO LULU cg a OwofQ U w >- >- MP1 Sealed For z Lo Z v) (1) #OF MODULES: 10 Existing Roof & Q z 00 PHOTOVOLTAIC UTILITY AC DISCONNECT. AZIMUTH: 157 Attachment Only U ~ Q 24/7 KEYLESS UNESCORTED ACCESS SHALL BE PITCH: 23 PROVIDED TO ALL XCEL ENERGY EQUIPMENT. TSRF: 81% DRAWING BY: AREA: 678 ft.2 Brendan Fillmore PLOT DATE: iCEN D FRONT OF HOME • = May 24, 2023 - PROJECT NUMBER: ENG E -52823 780719 �Q 5/25/23 T'• �0 SHEET NAME: I hereby certify that this plan,specification or report r 1 OF•Z ROOF PLAN was prepared by me or under my direct supervision and that I aazn a duly Licensed Professional Engineer under REVISION: PAGE NUMBER: the laws ofthe State of Minnesota.John A.Calvert, NO CLEARANCE ISSUES EXIST FOR OVERHEAD OR UNDERGROUND SERVICE LINES. License No.52823 Expiration Date:30-June-2024 0 PV3 STRUCTURAL INFORMATION: STRUCTURAL NOTES: PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 6.5" SPLICE ROOF TYPE (1): ROOF TYPE: Comp Shingle SHEATHING TYPE: OSB BLUE RAVEN FRAMING TYPE: Manufactured Truss Mounting planes have same framework FRAMING SIZE: 2x4 @ 24"OC CEILING JOIST SIZE: 2x4 @ 24" OC _ 16" _ 1403 N. Research Way MAX. 48 MAX. LANDSCAPE Orem, UT 84097 ATTACHMENT: SFM Infinity Flashkit 800.377.4480 RACKING: Unirac SFM Infinity WWW.BLUERAVENSOLAR.COM @ 24" OC Portrait/48" OC Landscape PV MODULE UNIRAC SFM 2" MICRORAIL UNIRAC SFM 8" CONFIDENTIAL-THE INFORMATION ATTACHED SPLICE HEREIN CONTAINED SHALL NOT BE NUMBER OF ATTACHMENTS: 43 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR PV MODULE COUNT: 16 Modules SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE TOTAL ARRAY AREA: 326.4 ft2(20.4ft2/panel) RECIPIENTS ORGANIZATION,EXCEPT TOTAL ROOF AREA: 3252 ft2 N CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, ARRAY/ROOF AREA: 10% WITHOUT THE WRITTEN PERMISSION ARRAY WEIGHT: 800 Ibs (50 Ibs/panel) — 8 Ir 24" MAX. - OF BLUE RAVEN SOLAR LLC. DISTRIBUTED LOAD: 2.45 Ibs/ft2 MAX. PORTRAIT POINT LOAD: 18.6 Ibs/attachment *NOTE:LISTED NUMBER OF ATTACHMENT POINTS ARE AN ESTIMATE ONLY AND MAY VARY ATTACHMENT SPACING- FRONT VIEW -RACKING ATTACHMENTS TO BE STAGGERED NABCEP BASED ON FIELD CONDITIONS.MAXIMUM ATTACHMENT SPACING TO BE FOLLOWED PER li ENGINEER OF RECORD SPECIFICATIONS. SCALE: 3/4" = 1'-0" CERTIFIED UNIRAC SFM INFINITY UNIRAC SFM MICRORAIL/SPLICE A PV INSTALLATION PV MODULE PROFESSIONAL �- Scott Gurney URE FBM40OMFG-BB #PV-011719-015866 PV MODULE B PORTRAIT CONTRACTOR: UNIRAC SFM SLIDER BRS FIELD OPS _ ROOF STRUCTURE 800-377-4480 (E) ROOF MODULE- SHEATHING - WIDTH FLASHING '= A cV co (1) 5/16" STAINLESS STEEL LAG BOLT �� ���� B Q LANDSCAPE WITH 2-1/2" MIN. EMBEDMENT f �- o CU AND FLAT WASHER 2 ' MIN. EMBED. �� 23° "- MODULE Z N co � — WIDTH C: � Q � N N W W MIDDLE/TOP STANDOFF DETAIL ATTACHMENT SPACING- SIDE VIEW _ a 2 N N A SCALE: 3" = T-0" (E) BUILDING STRUCTURE D SCALE: 1/2" = T-0" z_ w IY � Y J Fn Fn W w0 W W URE FBM40OMFG-BB LL � Q PV MODULE 0 z U w >. >. Sealed For cl) z Lo z cl) cl) Existing Roof & U < � a UNIRAC SFM TRIMRAIL Attachment Only FLASHING DRAWING BY: UNIRAC SFM SLIDER AND ``` 111111,11� Brendan Fillmore TRIMRAIL ROOF ATTACHMENT (E) ROOF �� N- CAt ,� SHEATHING � � . , (i ., PLOT DATE: F � ••.• • - May 24, 2023 'C' D (1) 5/16" STAINLESS STEEL LAG BOLT �� ��� _ ��� �� = = = PROJECT NUMBER: WITH 2-1/2" MIN. EMBEDMENT _ ENG _ 780719 AND FLAT WASHER 2Yz' MIN. EMBED. a 52823 �/ 5/25/23 -..•.. �0 SHEET NAME: Ihereb certify that this plan,specification report 'T�,OF M1 %N STRUCTURAL Y Y P P P �frrrrrt��� was prepared by me or under my direct supervision and �\ that I am a duly Licensed Professional Engineer under REVISION: PAGE NUMBER BOTTOM STANDOFF DETAIL : p \ the laws of the State of Minnesota.John A.Calvert,: 3"= 1'-0" 0 PV4 o (E) BUILDING STRUCTURE License No.52823 Expiration Date:30-June-2024 SCALE (1) 10 AWG THHN/THWN-2,CU.,BLACK(1-1) 19.4 A AC (2) 10 AWG THHN/THWN-2,CU.,BLACK(1-1) MAX 9.7 A A (1) 10 AWG THHN/THWN-2,CU.,BLACK(1-1) MAX 9.7 A A (1) 12-2 TC-ER,THHN/THWN-2,CU. MAX 9.7 A AC 15 (1) 10 AWG THHN/THWN-2,CU.,RED(1-2) 240 V AC 3 (2) 10 AWG THHN/THWN-2,CU.,RED(L 2) 240 V AC 2 (1) 10 AWG THHN/THWN-2,CU.,RED(1.2) 240 V A 1 (1) 6 AWG BARE,CU(EGC) 240 V AC (1) 10 AWG THHN/THWN-2,CU.,WHITE(N) (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) (1) 10 AWG THHN/THWN-2,CU.,GREEN(EGC) OR 10-2 OF-B W/G(OR NM-B),THHN/THWN-2,SOLID CU. (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT(Not Required for OF-B or NM-B Cable) INTERIOR EXTERIOR BLUE RAVEN 1403 N. Research Way Orem, UT 84097 800.377.4480 DESIGNER NOTES: ELECTRICAL NOTES: WWW.BLUERAVENSOLAR.COM LOAD SIDE BREAKER IN MSP.INTERIOR POI AC SYSTEM SIZE:4.64 KW AC CONFIDENTIAL-THE INFORMATION PV INVERTER VOLTAGE:240V HEREIN CONTAINED SHALL NOT BE AMPERAGE:1.21A AC USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE (16) URE FBM40OMFG-BB RECIPIENTS ORGANIZATION,EXCEPT ENPHASE IQ COMBINER 4 UL 1703 COMPLIANT IN CONNECTION WITH THE SALE AND (E)200A MAIN SERVICE PANEL X-IQ-AM1-240-4 (16) Enphase IQ8PLUS-72-2-US USE OF THE RESPECTIVE EQUIPMENT, (E)200A/2P MAIN BREAKER (SOLAR LOAD ONLY) UL 1741 COMPLIANT WITHOUT THE WRITTEN PERMISSION 4'W'W"PVC JB-1 EZ SOLAR OF BLUE RAVEN SOLAR LLC. PV AC DISCONNECT JUNCTION BOX JUNCTION BOX (E)200A/2P NON-FUSED (N)20A/2P L1 LOCKABLE,VISIBLE OPEN L, JB L, JB-1 L, (1) CIRCUIT OF N2 30A,240V,2-POLE L2 ___EGC �___L2 _ _ 8 MODULES NABCEP (E)LOADS *PV BREAKER TO BE LOCATED ENVOY AT OPPOSITE END OF BUSSING 15A/2P CERTIFIED FROM MAIN BREAKER N I 2 1 PV INSTALLATION (N)25A/2P (N)20A/2P L1 L1 L, I L, JB-1 L, PROFESSIONAL L2 L2 - _ (1) CIRCUIT OF N N L2 L2 L2 Scott Gurney EGC __ EGC _______________________---__ EGC ___EGC }___EGo �_ = 8 MODULES #PV-011719-015866 120/240 VAC N G I CONTRACTOR: 60HZ 3 2 1 1 PHASE I BRS FIELD OPS TO UTILITY I PHOTOVOLTAIC UTILITY AC DISCONNECT. SINGLE PHASE MICROINVERTERS 800-377-4480 GRID I G J VISIBLE OPEN, LOCKABLE, AND READILY ACCESSIBLE WITH 24/7 KEYLESS UNESCORTED RPA LOCATION. TEST AT THE LUGS ON ACCESS PROVIDED TO ALL XCEL ENERGY EQUIPMENT. THE BOTTOM OF THE BUS BAR IN cV THE PV COMBINER BOX. co UQ U -----------, Z I I (E)GROUNDING (N) "COPPER GROUND ROD, 0 Y ELECTRODE(S) — 8'LONG,MIN.U FROM(E) / r GROUNDING CONDUCTOR. ` — Q 0 Y IF REQUIRED,VERIFICATION WILL BE DONE TO � C z � ENSURE THE GROUNDING ELECTRODE SYSTEM IS GEC INSTALLED PER NEC G J CONGRUENT WITH CURRENT REQUIREMENTS.(NEC 250.64:6 OR 4 AWG SOLID I Y 250 PART III)IF NOT,A NEW GROUND ROD WILL BE COPPER GEC. 1� 0 — W W INSTALLED. Z w 0— U) U) O ' ._ W wO W W waLL HH OLU � Q fn (n HZUuJ >. >. U) Zti � (n Z =) Q 0 1-- DRAWING BY: Brendan Fillmore PLOT DATE: ' May 24, 2023 INTERCONNECTION NOTES PROJECT NUMBER: 705.12(B)(3)THE FOLLOWING METHOD(S) SHALL BE USED TO 780719 DETERMINE THE RATINGS OF BUSBARS: (2)WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SHEET NAME: SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE i- ELECTRICAL POWER-SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT REVISION: PAGE NUMBER: EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. UTILITY COMPANY: Xcel Energy MN PERMIT ISSUER: City of Fridley 0 PV5 MODULE SPECIFICATIONS UREFBM40OMFG-BB DESIGN LOCATION ANDTEMPERATURES CONDUCTOR SIZE CALCULATIONS '**A* e RATED POWER(STC) 400W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMP MICROINVERTERTO MAX.SHORT CIRCUIT CURRRENT(ISC)= 9.7AAC MODULE VOC 37.2 V DC STATE Minnesota JUNCTION BOX(1) MAX.CURRENT(ISC X1.25)= 12.1 A AC MODULE VMP 31.17 V DC CITY MINNEAPOLIS CONDUCTOR(TC-ER,COPPER(90°C))= 12 AWG BLUE RAVEN MODULE IMP 12.84 A DC WEATHER STATION MINNEAPOLIS/BLAINE CONDUCTOR RATING= 30 A MODULE ISC 13.68 A DC ASHRAE EXTREME LOW TEMP(°C) -26 AMB.TEMP.AMP.CORRECTION= 0.96 VOC CORRECTION -0.27%/°C ASHRAE 2%AVG.HIGH TEMP(°C) 35 ADJUSTED AMP.= 28.8 > 12.1 1403 N. Research Way VMP CORRECTION -0.32%/°C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 9.7AAC Orem, UT84097 7.4480 SERIES FUSE RATING 30 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 12.1 AAC a W W W.BLUERAVRAVENSOSOLAR.COM ADJ. MODULE VOC @ ASHRAE LOW TEMP 42.3 V DC NUMBER OF MODULES PER MPPT 8 8 CONDUCTOR(UF-B,COPPER(60°C))= 10 AWG CONFIDENTIAL-THE INFORMATION ADJ. MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 27.0 V DC DC POWER RATING PER CIRCUIT(STC) 3200 3200 CONDUCTOR RATING= 30 A HEREIN CONTAINED SHALL NOT BE TOTAL MODULE NUMBER 16 CONDUIT FILL DERATE= 1 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR MICROINVERTER SPECIFICATIONS Enphase IQ8+Microinverters STC RATING OF ARRAY 6400 AMB.TEMP.AMP.CORRECTION= 0.96 SHALL IT BE DISCLOSED IN WHOLE OR IN TO POWER POINTTRACKING(MPPT) MIN/MAX 30 - 58 V DC AC CURRENT @ MAX POWER POINT(IMP 9.7 9.7 ADJUSTED AMP.= 28.8 > 12.1 REC PIENRTS ORGANIZATION,EIXCEPT IN MAXI MUM I N P LIT VOLTAGE 60VDC MAX.CURRENT(IMP X 1.25) 12.1 12.1 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 9.7AAC USE OF THE CONNECTITH ION EQUIPALE MENT, USE OF THE RESPECTIVE EQUIPMENT, MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 20 COMBI N ER BOX(3) MAX.CURRENT(ISC X1.25)= 12.1 A AC WITHOUT THE WRITTEN PERMISSION MAXIMUM USABLE DC INPUT POWER 440 W MAX.COMB.ARRAY AC CURRENT(IMP) 19.4 CONDUCTOR(UF-B,COPPER(60°C))= 10 AWG OF BLUE RAVEN SOLAR LLC. MAXIMUM OUTPUT CURRENT 1.21 A AC MAX.ARRAY AC POWER 4640W AC CONDUCTOR RATING= 30 A AC OVERCURRENT PROTECTION 20A CONDUIT FILL DERATE= 0.8 NABCEP MAXIMUM OUTPUT POWER 290 W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. ✓RISE(V) VEND(V) %VRISE AMB.TEMP.AMP.CORRECTION= 0.96 CERTIFIED CEC WEIGHTED EFFICIENCY 97 % VRISE SEC.1(MICRO TO J BOX) 28.8 12 Cu. 0.93 240.93 0.39% ADJUSTED AMP.= 23.04 > 12.1 VRISE SEC.2(J BOX T0 COMBINER BOX) 45 10 Cu. 1.11 241.11 0.46% COMBI N ER BOX TO INVERTER RATED AMPS= 19.4AAC PV INSTALLATION AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC.3(COMBINER BOX TO POI) 5 10 Cu. 0.25 240.25 0.10% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 24.2 A AC PROFESSIONAL NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 2.28 242.28 0.95% CONDUCTOR(THWN-2,COPPER(75°C TERM.))= 10 AWG Scott Gurney #PV-011719-015866 NOMI NAL OPERATI NG AC FREQUENCY 47-68HZAC CONDUCTOR RATING= 35A MAXIMUM AC POWER 240VAAC P HOTOVOLTAIC AC DI SCON N ECT OUTPUT LABEL(N EC 690.54) CONDUIT FILL DERATE= 1 CONTRACTOR: MAXI MUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 19.4 A AC AMB.TEMP.AMP.CORRECTION= 0.96 BRS FIELD OPS MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 33.6 > 24.2 800-377-4480 co GROUNDING NOTES WIRING & CONDUIT NOTES ** LO Q U 1.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH [NEC 690.47]AND[NEC 250.50-60]SHALL BE 1. ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE O LO PROVIDED. PER [NEC 690.47], THE GROUNDING ELECTRODE SYSTEM OF AN EXISTING BUILDING MAY BE APPLICATIONS. Y USED AND BE BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR 2. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED CONDUCTOR(USE Q Z N INADEQUATE, OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE POLARIS BLOCK OR NEUTRAL BAR). CC USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 3.ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS DISALLOWED ABOVE G J (.0 2.THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN LIVE PARTS,MEYERS HUBS RECOMMENDED THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER) IF SMALLER THAN#6 AWG COPPER WIRE 4. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT OFF THE ROOF O CC� IJ,I �JJ PER [NEC 250.64(B)]. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SURFACE IN ACCORDANCE WITH[NEC 11 0.2,1 10.3(A-B)]. LL Q G N N SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER[NEC 250.64(C)]. 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH WITH ROOF SURFACE TO BE USED FOR WIRE Z W (L (� (� (� 3.GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN 8 AWG AND NO GREATER THAN 6 AWG MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT RUNS. _ _ COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2, AND SINGLE-CONDUCTOR CABLE LISTED AND Y J C 4.PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 250.122],AND ALL METAL IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT.ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS LV LJJ a 2 2 PARTS OR MODULE FRAMES ACCORDING TO[NEC 690.46]. REQUIRED. 55.MODULE CO NNECTION CIRCUITS SHALL BE A GROUNDED IN ACE SHALL BCORDANCE TO SUCH THAT THE REMOVAL OF A CONDUCTORS.ONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 690.8]FOR MULTIPLE 0 LL Q 6. THE GROUNDINGMODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER MODULE. 8.ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED AT LEAST 7/81,ABOVE z U W 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE THE ROOF SURFACE AND DERATED ACCORDING TO [NEC TABLE 310.15 (13)(2)(A)], [NEC TABLE U) z Lo Z (n (n MANUFACTURER'S INSTALLATION INSTRUCTIONS. 310.15(13)(3)(A)],&[NEC 310.15(B)(3)(C)]. _ [-- Z V V 8.ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH AS APPROPRIATE WHEN 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED,WET AND UV RESISTANT,AND UL Q C GROUNDING EQUIPMENT WITH TERMINATION GROUNDING LUGS. LISTED RATED FOR 60oV, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP U H G Q 9.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND GROUNDING DEVISES EDGES. EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 INSULATED, 90°C RATED, 10.GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER, SOLID OR STRANDED,AND BARE WHEN WET AND UV RESISTANT,RATED FOR 600V DRAWING BY: EXPOSED. 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND 11. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO [NEC 690.45] AND BE A MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. Brendan FIIImOre MINIMUM OF 10 AWG WHEN NOT EXPOSED TO DAMAGE (6 AWG SHALL BE USED WHEN EXPOSED TO 12.ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION DAMAGE). 13.VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS PLOT DATE: 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR CODED GREEN(OR MARKED 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC CONDUIT BETWEEN GREEN IF 4 AWG OR POSITIVE- M GREY) THE UTILITY AC DISCONNECT AND THE POINT OF CONNECTION SHALL HAVE 5..POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED 3.AL May 24, 2023 GROUNDED BUSHINGS AT BOTH ENDS. DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) 14. SYSTEM GEC SIZED ACCORDING TO [NEC 690.47], [NEC TABLE 250.66], DC SYSTEM GEC SIZED 16.AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1-BLACK, PHASE B OR L2-RED, PROJECT NUMBER: ACCORDING TO[NEC 250.166],MINIMUM 8 AWG WHEN INSULATED,6 AWG WHEN EXPOSED TO DAMAGE. PHASE C OR L3-BLUE,NEUTRAL-WHITE/GRAY 15. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENTS, AND USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY BE USED INSIDE 780719 CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH[NEC 250.134]OR[NEC 250.136(A)] USE-2 IS AVAILABLE AS UV WHITE REGARDLESS OF VOLTAGE. 17.RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE EITHER EMT, SHEET NAME: FMC, OR MC CABLE IF DC CURRENT COMPLYING WITH [NEC 690.31], [NEC 250.118(10)]. DISCONNECTING /� /� MEANS SHALL COMPLY WITH[NEC 690.13]AND[NEC 690.15]. E LEC C/�"LC S 19.CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE COMPLYING WITH[NEC 230.6(4)]AND SECURED NO GREATER THAN 6'APART PER[NEC 330.30(B)]. REVISION: PAGE NUMBER: 0 PV6 STANDARD LABELS ADDITIONAL LABELS '**A* e LABEL 1 LABEL 8 BLUE RAVEN WARNING FOR PV SYSTEM DISCONNECTING MEANS WHERE THE L WARNING PERMANENT PLAQUE OR DIRECTORY DENOTING THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE LOCATION OF ALL ELECTRIC POWER SOURCE ELECTRIC SHOCK HAZARD OPEN POSITION. IMAIN DISTRIBUTION UTILITY DISCONNECT(S) DISCONNECTING MEANS ON OR IN THE PREMISES 1403 N. Research Way (2017 NEC 690.13(B)] OWER TO THIS BUILDING IS ALSO SUPPLIED SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT Orem, UT 84097 TERMINALS ON THE LINE AND (2020 NEC 690.13(B)] ROM A ROOF MOUNTED SOLAR ARRAY WITH LOCATION AND AT THE LOCATION(S)OF THE SYSTEM 800.377.4480 LOAD SIDES MAY BE ENERGIZED A RAPID SHUTDOWN DISCONNECTING MEANS DISCONNECT(S)FOR ALL ELECTRIC POWER WWW.BLUERAVENSOLAR.COM IN THE OPEN POSITION GROUPED AND LABELED WITHIN LINE OF SITE PRODUCTION SOURCES CAPABLE OF BEING AND 10 FT OF THIS LOCATION INTERCONNECTED. CONFIDENTIAL-THE INFORMATION (2017 NEC 705.101 HEREIN CONTAINED SHALL NOT BE (2020 NEC 705.101 USED FOR THE BENEFIT OF ANYONE LABEL 2 EXCEPT BLUE RAVEN SOLAR NOR PHOTOVOLTAIC SYSTEM SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT SHALL IT BE DISCLOSED IN WHOLE OR THE DISCONNECTING MEANS AS A POWER SOURCE LABEL 9 IN PART TO OTHERS OUTSIDE I ACDISCONNECTAND WITH THE RATED AC OUTPUT CURRENT AND THE E WA RN I N G PERMANENT PLAQUE OR DIRECTORY DENOTING THE RECIPIENTS ORGANIZATION,EXCEPT NOMINAL OPERATING AC VOLTAGE. LOCATION OF ALL ELECTRIC POWER SOURCE N CONNECTION WITH THE SALE AND (2017 NEC 690.54] USE OF THE RESPECTIVE EQUIPMENT, RATED AC OUTPUT CURRENT 19.36 A POWER TO THIS BUILDING IS ALSO DISCONNECTING MEANS ON OR IN THE PREMISES WITHOUT THE WRITTEN PERMISSION (2020 NEC 690.541 SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT OF BLUE RAVEN SOLAR LLC. NOMINAL OPERATING AC VOLTAGE 240 V SUPPLIED FROM MAIN DISTRIBUTION LOCATION AND AT THE LOCATION(S)OF THE SYSTEM UTILITY DISCONNECT LOCATED DISCONNECT(S)FOR ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING /� INTERCONNECTED. NAB C E P LABEL 3 (2017 NEC 705.101 IF INTERCONNECTING LOAD SIDE,INSTALL THIS LABEL (2020 NEC 705.101 CERTIFIED ANYWHERE THAT IS POWERED BY BOTH THE UTILITY DUAL POWER SUPPLY AND THE SOLAR PV SYSTEM,IE.MAIN SERVICE PANEL AND SUBPANELS. PV INSTALLATION [2017 NEC 705.12(B)(3)] LABEL EN PROFESSIONAL SOURCES: UTILITY GRID AND (2020 NEC 705.12(B)(3)] I WARNING PERMANTPLAQUE DIRECTORYTOBE PV SOLAR ELECTRIC SYSTEM LOCATED AT MAIN SERVVICE EQUIPMENT DENOTING Scott Gurney POWER TO THIS BUILDING IS ALSO SUPPLIED THE LOCATION OF THE RAPID SHUTDOWN SYSTEM #PV-011719-015866 FROM A ROOF MOUNTED SOLAR ARRAY.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID SHUTDOWN DISCONNECTING SWITCH IS NOT CONTRACTOR: ARRAY RAPID SHUTDOWN DISCONNECT IS GROUPED AND WITHIN LINE OF SITE OF MAIN OIWARNING LABEL4 BRS FIELD OPS APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT LOCATED OUTSIDE NEXTTOTHE UTILITY METER. SERVICE DISCONNECTING MEANS. TO THE BACK-FED BREAKER FROM THE POWER (2017 NEC 705.10 AND 690.56(C)(1)(a)] 800-377-4480 POWER SOURCE OUTPUT CONNECTION SOURCE. (2020 NEC 705.10 AND 690.56(C)] DO NOT RELOCATE [2017 NEC 705.12(B)(2)(3)(b)] (2020 NEC 705.12(B)(3)(2)] THIS OVERCURRENT WARNING LA N DEVICE PERMANENT T PLAQUE OR DIRECTORY TO BE � U I LOCATED AT AC COMBINER PANEL. '' Q U P [2017 NEC 110.21(B)] Z PHOTOVOLTAIC SYSTEM O WA R N I N G LABEL 5 (2020 NEC 110.21(B)] o APPLY TO THE PV COMBINER BOX COMBINER PANEL P: O (2017 NEC 705.12(B)(2)(3)(c)] Q [2020 NEC 705.12(B)(3)(3)] DO NOT ADD LOADS z � THIS EQUIPMENT FED BY MULTIPLE Y SOURCES.TOTAL RATING OF ALL Q OVERCURRENT DEVICES,EXCLUDING IL Q NN MAIN SUPPLY OVERCURRENT SUBPANEL Z W IZ U) U) Illy) DEVICE,SHALL NOT EXCEED UTILITY MAIN IF INTERCONNECTION AC PV PV COMBINER AMPACITY OF BUSBAR. METER SERVICE PANEL IS MADE HERE) DISCONNECT METER BOX Y J WawO W W W 0- LABEL 5 0 0 O O e (a) O O 0 LU C) Lu wUw SOLAR PV SYSTEM EQUIPPED BUILDINGS WITH PV SYSTEMS SHALL HAVE A U) z Lo Z U) U) WITH RAPID SHUTDOWN PERMANENT LABEL LOCATED AT EACH SERVICE T O Q � z O OO V V EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS V Q Q TURN RAPID SHUTDOWN ARE CONNECTED OR AT AN APPROVED READILY "OFSWITCH F"POSITION TO VISIBLE LOCATION AND SHALL INDICATE THE LOCATION0 O F BREAKER O O OOR PLACARD 11 SHUT DOWN PV SYSTEM OF RAPID SHUTDOWN INITIATION DEVICES. IS USED DRAWING BY: AND REDUCE SHOCK HAZARD (2017 NEC 690.56(C)(1)(a)] IN THE ARRAY (2020 NEC 690.56(C)] ( OR 10 Brendan Fillmore OR PLACARD PLOT DATE: RAPID LABEL 7 May 24, 2023 SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT SWITCH FOR SWITCH (2017 NEC 690.56(C)(3)] PROJECT NUMBER: SOLAR PV SYSTEM (2020 NEC 690.56(C)(2)] 780719 LABELING NOTES SHEET NAME: 1)LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE EXACT LABELS REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL 2)LABELING REQUIREMENTS BASED ON THE 2017&2020 NEC CODE,OSHA STANDARD 19010.145,ANSIZ535. REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED 3)MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. REVISION: PAGE NUMBER: 4)LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 HANDWRITTEN[NEC 110.21] DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. '**A* e BLUE RAVED CAUT ON 1403 N. Research Way Orem, UT 84097 MULTIPLE SOURCES OF POWER 8 W W W.BLUERAVRAVENSOSOLAR.COM DOWER TO THIS BUHEDM IS ALSO SUPPLIED FROM THE CONFIDENTIAL-THE INFORMATION HEREIN SHALLBE _OWING SOURCES WITH DISCONNECTS LOCATED AS SHMA/ USED FOROTHEABENDEFITOFANOYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED ROOFTOP PV ARRAY F M- - PV INSTALLATION PROFESSIONAL Scott Gurney MAIN SERVICE DISCONNECT #PV-011719-015866 UTILITY METER CONTRACTOR: BRS FIELD OPS 800-377-4480 m ROOFTOP PV ARRAY PV AC DISCONNECT SWITCH M U Q U Z Lo 0 FRONT OF HOME 0 o Y CU 1475 CREEK PARK LN z N � WNNEAPOHS WNNESOTA 55432 w Y �_ 00 Q � N N Z W 0- (n (n in Y J 22 WaWD W W W 0- � 11.— ofQ cnfn OLU Z U Z Z ti Z_ U H Q DRAWING BY: Brendan Fillmore PLOT DATE: DIRECTORY PLACARD NOTES May 24, 2023 PROJECT NUMBER: [NEC 705. 10]A PERMANENT PLAQUE OR DIRECTORY DENOTING THE 780719 LOCATION OF ALL ELECTRIC POWER SOURCE DISCONNECTING MEANS ON OR IN THE PREMISES SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT SHEET NAME LOCATION AND AT THE LOCATION(S) OF THE SYSTEM DISCONNECT(S) FOR PLACARD ALL ELECTRIC POWER PRODUCTION SOURCES CAPABLE OF BEING REVISION PAGE NUMBER INTERCONNECTED. THE MARKING SHALL COMPLY WITH [110.21(B)]. 0 PV8 ® UREE0 BLUE RAVEN UREE0 sol 1403 N.Research Way United Renewable Energy Co., Ltd. Orem.UT 84097 United Renewable Energy Co., Ltd. 800.377.4480 W W W.BLUERAVENSOLAR.COM Electrical Data CONFIDENTIAL-THE INFORMATION Model-STC FBM390MFG-BB FBM395MFG-BB FBM40OMFG-BB FBM405MFG-BB HEREIN CONTAINED SHALL NOT BE Maximum Rating Power(Pmax) [W] 390 395 400 405 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR C R C rillModule Efficiency [%] 19.98 20.23 20.49 20.75 SHALL IT BE DISCLOSED IN WHOLE OR Open Circuit Voltage(VOC) IV] 36.84 37.03 37.20 37.36 IN PART TO OTHERS OUTSIDE Maximum Power Voltage IV] 1 30.82 31.00 31.17 31.36 RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND FBM_MFG-BB / 108 cells Short Circuit Current(Isc) [A] 13.50 13.59 13.68 13.78 USE OF THE RESPECTIVE EQUIPMENT, Maximum Power Current [A] 12.66 12.75 12.84 12.92 WITHOUT THE WRITTEN PERMISSION 390 W - 405 W *Standard Test Condition(STC):Cell Temperature 25°C,Irradiance 1000 W/m�,AM 1.5 OF BLUE RAVEN SOLAR LLC. " *Values without tolerance are typical numbers.Measurement tolerance:±3% Mono-Crystalline PV Module NABCEP URE Peach module uses URE state-of-the a Mechanical Data Operating Conditions CERTIFIED cutting technology, and advanced mod Item Specification Item Specification PV INSTALLATION manufacturing experiences. Dimensions 1723 mm(L)1 x 1133 mm(W)1 x 35 mm(D)2 / Mechanical Load 5400 Pa PROFESSIONAL \ ! 67.83" L 1 x 44.61" W 1 x 1.38 D 2 Maximum System Voltage 1000V Scott Gurney Weight 21.7 kg/47.84 Ibs Series Fuse Rating 30 A #PV-011719-015866 Solar Cell 12x9 pieces monocrystalline solar cells series strings Operating Temperature -40 to 85°C Front Glass White toughened safety glass,3.2mm thickness Temperature Characteristics CONTRACTOR: Cell Encapsulation EVA(Ethylene-Viny-Acetate) BRS FIELD OPS Frame Black anodized aluminum profile Item Specification Junction Box IP>68,3 diodes Nominal Module Operating Temperature 45°C±2°C 385-498-6700 Cable 1200 mm(cable length can be customized),4mm2 Temperature Coefficient of Isc 0.048%/°C Connector Type MC4/MC4 Compatible Temperature Coefficient of Voc -0.27%/°C Package Configuration 31 pcs Per Pallet,806 pcs per 40'HQ container Temperature Coefficient of Pmax I -0.32%/°C 1•With assembly tolerance of±2 mm[±0.08"] *Nominal module operating temperature(NMOT):Air mass AM 1.5, T, C E z•With assembly tolerance of mm[±0.03"] irradiance SOOW/ma,temperature 20°C,windspeed 1 m/s. . *Reduction in efficiency from 1000W/m'to 200W/m2 at 25°C:3.5±2%. CH@ 1`N S�o • ffi UL 61730,CE-compliant Engineering Drawing(mm) Dependence on Irradiance Quality Controlled PV-TOV SUD la IEC 61215:2016,IEC 61730:2016 1000 w/m' Key Features to 800W/m' _ $ 600 W/m' u' 6 (� Positive power tolerance '�� 100% EL inline inspection _U 400W/m'+I +I +l a +0—+5 watt + = Better module reliability — 2 200 W/m' 0 IB00 Y 0 5 10 15 20 25 30 35 40 Withstand heavy loading Design for 1000 VDC voltage IV] Temperature 25°C Front load 5400 Pa & rear load 2400 Pa Reduce the system BOS effectively 0oa my I Illdn�ill I I I I I I '''''' B Reliability wit Warranty 25year a 1133±1 1092±1 _ ,00x Additional value from warranty FRONT VIEW BACK VIEW Excellent low light performance URE 3.5/0 0 Fire resistance A A B_Mounting Hole 3.5/ relative eff. Reduction at low ��� Class of reaction to Type 1/Class C Frame a place «ENr (200W/m2) 10 - 9_ t , 1 a% r s a zo 35 _ Years For more information,please visit us at www.urecorp.com • SHEET NAME: URECO Taipei Office 9F,NO.295,Sec.2,Tiding Blvd., Headquarters Hsi 7,u cit n 3rd Road,Hsinchu Science Park FI 1 •� Neihu Dist.,Taipei 11493,Taiwan Hsinchu city30078,Taiwan SPEC SHEETS {r United Renewable Energy Co.,Ltd. Tel:+886-2-2656-2000 Tel:+886-3-578-0011 FFax:+886-2-2656-0593 Fax:+886-3-578-1255 REVISION: PAGE NUMBER: For more information,please visit us at www.urecorp.comiim .• e-mail:sales@urecorp.com opyright©2022 URE Corp.All rights reserved Copyright©2022 URE Corp.All rights reserved URECO_US_Peach_FBM_MFG-BB_V1_3.2_35mm_BS_EN_220602 0 SS `4% FLUE RAVEN soi ENPHASE. IQ8 and IQ8+ Microinverters 1403N Research Way Orem,UT 84097 INPUT DATA i 800.377.4480 Commonly used module pairings' w 235-350 235-440 WWW.BLUERAVENSOLAR.COM Module compatibility 60-cell/120half-cell 60-cell/120 half-cell,66-cell/132 half-cell and72-cell/144 CONFIDENTIAL-THE INFORMATION half-cell HEREIN CONTAINED SHALL NOT BE MPPT voltage range v 27-37 29-45 USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR Operating range v 25-48 25-58 SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Min/max start voltage v 30/48 30/58 RECIPIENTS ORGANIZATION,EXCEPT Max input DC voltage v 50 60 IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, Max DC current'[module lsc] A 15 WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. 0 Overvoltage class DC port II 0 DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit NAB C E P r CERTIFIED Peak output power VA 245 300 PV INSTALLATION Max continuous output power VA 240 290 PROFESSIONAL Nominal(L-L)voltage/range' v 240/211-264 Scott Gurney Max continuous output current A 1.0 1.21 #PV-011719-015866 IQ8 and IQ8+ Microinverters Nominal frequency Hz 60 CONTRACTOR: Easy to install Extended frequency range Hz 50-68 BRS FIELD OPS Our newest I08 Microinverters are the industry's first microgrid-forming,software- Lightweight and compact with AC short circuit fault current over 2 385-498-6700 defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors 3 cycles Arms power to AC power efficiently.The brain of the semiconductor-based microinverter Power Line Communication Max units per 20A(L-L)branch circuit4 16 13 is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components Total harmonic distortion <5% microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times Faster installation with simple Overvoltage class AC port III to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling AC port backfeed current mA 30 energy systems. Power factor setting 1.0 High productivity and reliability Grid-tied power factor(adjustable) 0.85leading-0.85lagging Produce power even when the Peak efficiency % 97.5 97.6 .,,,,•� a Enphasegrid is down* `" CEC weighted efficiency % 97 97 More than one million cumulative Nigh-time power consumption mW 60 ,k5 MIT --my hours of testing year limited MECHANICAL ATA Class II double-insulated r Part of the Enphase Energy System,I08 Series I08 Series Microinverters redefine reliability enclosure Ambient temperature range -40°C to+60°C(-40°F to+140°F) Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative Optimized for the latest high- Relative humidity range 4%to 100%(condensing) • Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- DC Connector type MC4 and analysis software. leading limited warranty of up to 25 years. powered PV modules Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Microgrid-forming Weight 1.08 kg(2.38lbs) Complies with the latest Cooling Natural convection-no fans advanced grid support** Approved for wet locations yes 6b::C CERTIFIED Remote automatic updates for Pollution degree PD3 L SAFETY -A DRAWING BY: the latest grid requirements Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Connect PV modules quickly and easily to IQ8 Series I08 Series Microinverters are UL Listed as ura Confi ble to support Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with g PPort a w Environ.category/UV exposure rating NEMA Type 6/outdoor cable with plug-n-play MC4 connectors. various regulations,when installed according to range of grid profiles COMPLIANCE PLOT DATE: manufacturer's instructions. Meets CA Rule 21(LIL 1741-SA) CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 N0.107.1-01 requirements Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to PROJECT NUMBER: 02022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,I08 Microinverters,and other *Only when installed with IQ System Controller 2, manufacturer's instructions. names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. (1)No enforced DC/AC ratio.See the compatibility calculator at https://linLenphase.com/module-compatibility **I08 and I08PIus supports split phase,240V (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required I08SP-DS-0002-01-EN-US-2022-03-17 installations only. by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. I08SP-DS-0002-01-EN-US-2022-03-17 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: `4% IQ Combiner 4/4C BLUE RAVEN Data Sheet Sol Enphase Networking MODEL NUMBER 1403 N.Research Way Orem,UT 84097 IQ Combiner 4 IQ Combiner4with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.51/) X-IQ-AM1-240-4 and consumption monitoring(±2.5%).Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to 800.377.4480 X2-IQ-AM1-240-4(IEEE 1547:2018) deflect heat. WWW.BLUERAVENSOLAR.COM IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%) CONFIDENTIAL-THE INFORMATION X-IQ-AM1-240-4C and consumption monitoring(±2.51/).Includes Mobile Connect cellular modem(CELLMODEM-M1-06-SP-05),a plug-and-play HEREIN CONTAINED SHALL NOT BE IQ Combiner 4/4C The IQ Combiner 4/4C with IQ Gateway and X2-IQ-AM1-240-4C(IEEE 1547:2018) industrial-grade cell modem for systems up to 60 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the USED FOR THE BENEFIT OF ANYONE US Virgin Islands,wherethereisadequatecellularserviceintheinstallationarea)Includesasilversolarshieldtomatchthe EXCEPT BLUE RAVEN SOLAR NOR integrated LTE-M1 cell modem (included IQ Battery and IQ System Controller and to deflect heat. SHALL IT BE DISCLOSED IN WHOLE OR only with lQ Combiner 4C) consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) IN PART TO OTHERS OUTSIDE Supported microinverters IQ6,IQ7,and IQ8.(Do not mix IQ6/7 Microinverters with IQ8) RECIPIENTS ORGANIZATION,EXCEPT interconnection equipment into a single INCOFTHE ON WITH EQUIPALE MENT, D Communications Kit USE OF THE RESPECTIVE EQUIPMENT, enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-M1-06 -Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05with 5-year Sprint data plan WITHOUT THE WRITTEN PERMISSION CELLMODEM-M1-06-SP-05 -4G based LTE-M1 cellular modem with 5-year Sprint data plan OF BLUE RAVEN SOLAR LLC. storage installations by providing a consistent, CELLMODEM-M1-06-AT-05 -4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. �ENPHASE pre-wired solution for residential applications. BRK-10A-2-240V Circuit breaker,2 pole,10A,Eaton BR210 NABCEP BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 It offers up to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 CERTIFIED BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support Eaton BR series busbar assembly. BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES Replacement solar shield for IQCombiner4/4C PV INSTALLATION XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) PROFESSIONAL X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws Scott Gurney #PV-011719-015866 Consumption monitoring CT A pair of 200A split core current transformers Smart (CT-200-SPLIT/CT-200-CLAMP) CONTRACTOR: ELECTRICAL SPECIFICATIONS BRS FIELD OPS • Includes IQ Gateway for communication and control Rating Continuous duty Includes Mobile Connect cellular modem 385-498-6700 (CELLMODEM-Ml-06-SP-05),included only with System voltage 120/240VAC,60 Hz IQ Combiner 4C Eaton BR series busbar rating 125A Includes solar shield to match Enphase IQ Battery Max.continuous current rating 65A aesthetics and deflect heat Max.continuous current rating(input from PV/storage) 64A Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 90A Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Provides production metering and consumption Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway Simple MECHANICAL DATA X-IQ-AM1-240-4C Mounts on single stud with centered brackets Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. • X2-IQ-AM1-240-4C(IEEE 1547:2018) Supports bottom,back and side conduit entry Weight 7.5 kg(16.5lbs) Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -400C to+46°C(-40°F to 1150F) plug-in breakers(not included) Cooling Natural convection,plus heat shield 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20A to 50A breaker inputs:14 to 4 AWG copper conductors .I Reliable 60A breaker branch input:4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14 to 1/0 copper conductors Durable NRTL-certified NEMA type 3R enclosure Always follow local code requirements for conductor sizing. Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS included for both the IQ Combiner SKU's Integrated Wi-Fi IEEE 802.11b/g/n X-IQ-AMl-240-4 UL listed � Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1.06-AT-05(4G based LTE-M1 cellular modem).Note that an Mobile Connect X2-I Q-AM 1-240-4 and X2-I Q-AM 1-240-4C comply with cellular modem is required for all Enphase Energy System installations. X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 1547:2018 rd UL 1741-SB,3 Ed. ( ) Ethernet Optional,IEEE 802.3,CatSE(or Cat6)UTP Ethernet cable (not included) COMPLIANCE Compliance,IQ Combiner CA Rule 21(UL 1741-SA) U1 IEEE 1547:2018-UL 1741-SB,31d Ed.(X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) ` CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 LISTED Production metering:ANSI C12.20 accuracy class 0.5(PV production) Consumption metering:accuracy class 2.5 E N P H A S E To learn more about Enphase offerings,visit enphase.com `04 Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 SHEET NAME: IQ-C-4-4C-DS-0103-EN-US-12-29-2022 ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject tochange. IQ-C-4-4C-DS-0103-EN-US-12-29-2022 SPEC SHEETS REVISION: PAGE NUMBER: 0 SS BLUE RAVEN 1403 N.Research Way Orem,UT 84097 WIRING DIAGRAMS 800.377.4480 W WW.BLUERAVENSOLAR.COM 6.75 FUSIBLE NOT FUSIBLE CONFIDENTIAL-THE INFORMATION [172] HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR 28 SHALL IT BE DISCLOSED IN WHOLE OR [7] _ Q Q IN PART TO OTHERS OUTSIDE I/ I/ RECIPIENTS ORGANIZATION,EXCEPT (3 HOLES) A C r 7 IN CONNECTION WITH THE SALE AND b/ 6 USE OF THE RESPECTIVE EQUIPMENT, „ WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. S N 9.00 NABCEP 6.00 [2292s] � � � [1521 g A,B,C B D p CERTIFIED � f-� KNOCKOUTS b PV INSTALLATION PROFESSIONAL S N Scott Gurney o #PV-011719-015866 A,B,C TERMINAL LUGS$ 4.50 KNOCKOUTS 4.60 CONTRACTOR: [1141 [117] BRS FIELD OPS AMPERES MAX. WIRE MIN. WIRE TYPE 385-498-6700 7.50 # 6 AWG # 12 AWG AL 30 # 6 AWG # 14 AWG CU [191]~ KNOCKOUTS SYMBOL A B C D O A,B,C CONDUIT SIZE .50 .75 1 1.25 KNOCKOUTS NEMA TYPE 3R ILLUSTRATED DUAL DIMENSIONS: INCHES MILLIMETERS A,B,C,D KNOCKOUTS HORSEPOWER RATINGS CATALOG VOTAGE WIRING 120VAC 240VAC NUMBER RATINGS DIAG. STD. MAX. STD. MAX. 10 10 10 30 10 30 D211NRB•0 240VAC A 1/2 2 1 1/2 — 3 — NOTES: D221NRB 240VAC A — — 1 1/2 3* 3 7 1/2* FINISH — GRAY BAKED ENAMEL ELECTRODEPOSITIED OVER CLEANED PHOSPHATIZED STEEL. D321NRB 240VAC B — — 1 1/2 3 3 7 1/2 UL LISTED — FILE E-2875 DRAWING BY: ALL NEUTRALS — INSULATED GROUNDABLE DU221RB 240VAC C — — — — 3 — SUITABLE FOR USE AS SERVICE EQUIPMENT DU321RB 240VAC D — — — — 3 7 1/2 TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT—ON HUB. SHORT CIRCUIT CURRENT RATINGS: • 10,000 AMPERES. PLOT DATE: 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES. GENERAL DUTY SAFETY SWITCHES r ' 100,000 AMPERES WITH CLASS R FUSES. VISIBLE BLADE TYPE * FOR CORNER GROUNDED DELTA SYSTEMS. 30 AMPERE ■ PLUG FUSES by Schneider Electric LUGS SUITABLE FOR 60-C OR 75' CONDUCTORS. ENCLOSURE — NEMA TYPE 3R RAINPROOF PROJECT NUMBER: O.N 1852 0. FEBRUARY 2014 REF DWG #1852 SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ---- SS JB- 1 . 2 EZf SOLAR PHONE:385-202-4150 *10% EZf SOLAR Specification Sheet making solarslmple, WWW.EZSOLARPRODUCTS.COM BLUE RAVED making solar simple, PV Junction Box for Composition/Asphalt Shingle Roofs 1403 N.Research Way A. System Specifications and Ratings Orem,UT84097 Y p 9 ITEM N0. PART NUMBER DESCRIPTION OTY slzE DWG.No. REV 800.377.4480 POLYCARBONATE WWW.BLUERAVENSOLAR.COM • Maximum Voltage: 1,000 Volts 1 JB-1.2 BODY 1 CONFIDENTIAL-THE INFORMATION WITH UV INHIBITORS SCALE: WEIGHT: LBS SHEET 1 OF 3 HEREIN CONTAINED SHALL NOT BE • Maximum Current: 80 Amps USED FOR THE BENEFIT OF ANYONE POLYCARBONATE EXCEPT BLUE RAVEN SOLAR NOR • Allowable Wire: 14 AWG —6 AWG 2 JB-12 LID 1 SHALL IT BE DISCLOSED IN WHOLE OR WITH UV INHIBITORS TORQUE SPECIFICATION: 15-20 LBS N PART TO OTHERS OUTSIDE • S Spacing:: Please maintain a s acin of at least 1/2" between uninsulated live arts and fittin s for RECIPIENTS ORGANIZATION,EXCEPT p g spacing p g IN CONNECTION WITH THE SALE AND conduit, armored cable, and uninsulated live parts of opposite polarity. #10 X 1-1/4"PHILLIPS UL STANDARD 1741, USE OF THE RESPECTIVE EQUIPMENT, • Enclosure Rating: Type 3R 3 PAN HEAD SCREW NEMA 3R OF BLUE RAVEN SOLAR LLC. • Roof Slope Range: 2.5— 12:12 4 #8 X 3/4"PHILLIPS 6 WEIGHT: 1.45 LBS rNABCEP • Max Side Wall Fitting Size: 1" PAN HEAD SCREW • Max Floor Pass-Through Fitting Size: 1" 1 CERTIFIED • Ambient Operating Conditions: (-35°C) - (+75°C) PV INSTALLATION • Compliance: PROFoESSIONAL Gurneytt - JB-1.2: UL1741 #PV-011719-015866 -Approved wire connectors: must conform to UL1741 CONTRACTOR: • System Marking: Interek Symbol and File#5019942 / BRS FIELD OPS • Periodic Re-inspections: If re-inspections yield loose components, loose fasteners, or any corrosion 385-498-6700 between components, components that are found to be affected are to be replaced immediately. Table 1:Typical Wire Size,Torque Loads and Ratings Torque 1 Conductor 2 Conductor Type NM Inch Lbs Voltage Current ABB ZS6 terminal block 10-24awg 16-24awg Sol/Str 0.5-0.7 6.2-8.85 600V 30amp ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 amp ® g ABB ZS16 terminal bock 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp �a ABB M6/8terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp [279.68mm] [276.30mm] i 1 ].Olin 10.88in Ideal452 Red WING-NUTWire o 8-18awg Sol/Str Self Torque Self Torque 600V Connector SOLAR � L� Ideal 451 Yellow WING-NUT III \ O L A R III 10-18 awg Sol/Str Self Torque Self Torque 600V o w rr� Wire Connector Ideal,In-Sure Push-In 10-14awg Sol/Str Self Torque Self Torque 600V III III Connector Part#39 o �B-).2 n WAGO,2204-1201 10-20 awg 16-24 awg Sol/Str Self Torque Self Torque 600V 30 amp III III WAGO,221-612 10-20 awg 10-24 awg Sol/Str Self Torque Self Torque 600V 30 amp Dottie DRC75 6-12 awg Sol/Str Snap-In Snap-In 4-6 awg Sol/Str 45 ESP NG-53 2000V , 10-14 awg Sol/Str 35 ------------- ESP NG-717 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 35 1 DRAWING BY: 4-6 awg Sol/Str 45 Brumall4-5,3 2000V [ 10-14awg sol/str 35 [183.06mm] 72.53mm 7.21 in 2.86in PLOT DATE: Table 2:Minimum wire-bending space for conductors through a wall opposite terminals in mm(inches) [265.18mm] Wire size,AWG or Wires per terminal(pole) 10.44in 1 2 3 4 or More PROJECT NUMBER: kcmil (mm2) mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not specified - - 8 (8.4) 38.1 (1-1/2) SHEET NAME: 6 (13.3) 1 50.8 (2) SPEC SHEET REVISION: PAGE NUMBER: EZf SOLAR PHONE:385-202-4150 1 WWW.IZSOLARPRODUCTS.COM PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED INTHIS DRAWING ISTHE SOLE PROPERTYOF EZSOLAR. ———— SS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. `4% Rigid Nonmetallici i Boxes BLUE RAVED SP Carion• 1403 N.Research Way Molded Nonmetallic Junction Boxes Except where noted Orem UT 84097 LISTED by E42728 800.377.4480 VIEW SHOWN LESS WWW.BLUERAVENSOLAR.COM 6P Rated COVER FOR CLARITY 3.70 CONFIDENTIAL-THE INFORMATION [941 0.20 HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE It's another first from Carlon® the first nonmetallic r� [5, I 1 EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR junction boxes LIL Listed with a NEMA 6P rating per IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT Section 314.29,Exception of the National Electrical Code. AIN CONNECTION WITH THE SALE AND Manufactured from PVC or PPO thermoplastic molding USE OF THE RESPECTIVE EQUIPMENT, p g 3.70 WITHOUT THE WRITTEN PERMISSION compound and featuring foam-in-place gasketed lids [941 4 50 OF BLUE RAVEN SOLAR LLC. attached with stainless steel screws,these rugged [541 [12 71 enclosures offer all the corrosion resistance and physical NABCEP properties you need for direct burial applications. Type 6P enclosures are intended for indoor or outdoor CERTIFIED _ use,primarily to provide a degree of protection against PV INSTALLATION contact with enclosed equipment,falling dirt,hose- PROFESSIONAL Scott Gurney directed water,entry of water during prolonged B #PV-01 1 71 9-01 581i1i submersion at a limited depth,and external ice f CONTRACTOR: formation. BRS FIELD OPS Tc 385-498-6700 •All Carlon Junction Boxes w are LIL Listed and maintain O O_ O AT - !r a minimum of a NEMA Type �r 4/4x Rating. CO � o II • Parts numbers with an H OF B ° D asterisk(*)are LIL Listed and SIZE A e c maintain a NEMA Type 6P E989NNJ 2.00 4.63 5.13 O O RatingandT Type Rating. E989NNJB (50,8) (II7,6) (130,2) I w yp g' E989NNJ-CAR A TO E989NNJCL _ E989NNJL O O O AB T� 14X4X2) E989NNR fi.00 5.00 5.50 E989NNR-CAR 1152.d1 1127,0) 1139,7) I (4X4X6) I . 15 j Size in Std. Material Std. [3 81 Inches Ctn. Min Min. Min. Min. Ta Tc Thermo- Ctn. Part No. H x W x D Qty. AT AB B C Typical PVC plastic Wt.(Lbs.) E989NNJ-CAR* 4 x 4 x 2 5 311/16 35/8 N/A 2 .160 .155 X 3 E987N-CAR* 4x4x4 5 311/16 31/2 N/A 4 .160 .155 X 4 NOTES: I. ATERIAL: PVC SECTION 14-14 tE989NNR-CAR* 4x4x6 4 311/16 33/8 N/A 6 .160 .200 X 5 2. NEMA TYPES: 4/4X, 6P C SCALE 0,500 E989PP1-CAR* 5 x 5 x 2 4 411/16 41/2 N/A 2 .110 .150 X 3 E987R-CAR* 6 x 6 x 4 2 6 55/8 N/A 4 1 .190 .190 X 3 DRAWING BY: E989RRR-UPC* 6 x 6 x 6 8 55/8 53/8 N/A 6 .160 .150 X 14 GENERAL NOTES E989N-CAR 8 x 8 x 4 1 8 8 N/A 4 .185 .190 X 2 1. ALL DIMENSIONS ARE FOR REFERENCE ONLY. www.in— b.corn PLOT DATE: E989SSX-UPC 8 x 8 x 7 2 721/32 75/16 N/A 7 .160 .150 X 6 2. DIMENSIONS I N BRACKETS I I E989UUN 12 x 12 x 4 3 115/8 11112 111/8 4 .160 .150 x 12 ARE IN MEETTH��N I TS. DESCRIPTION: MOLDED NON-METALLIC ENCLOSURE E989R-UPC 12 x 12 x 6 2 1115/16 117/8 117/16 6 .265 .185 X 10 F PROJECT NUMBER: SEE ERN 20 16 195 FOR APPROVAL SIGNATURES ORIGINAL PROJECT NO I I ERN NO 1 1 SHEET NO: I REV. NO: I DRAWING NO: PROJECTS NO: 5AM000OD6 / 1 1 2 OF 2 F WSD-AC01977 THIS DRAWING IS INTENDED FOR DESCRIPTIVE PURPOSES ONLY. AND THE RIGHT IS RESERVED TO DEVIATE FROM ANY OF THE DETAILS SHOWN HEREON. SHEET NAME: 180 www.carIon.com Copyright Thomas A Betis - Proprietary, All Rights Reserved Gross Automation (877)268-3700 -www.carionsales.com -sales@grossautomation.com SPEC SHEET REVISION: PAGE NUMBER: ---- SS `4% BLUE RAVED SFM INFINITY U111111, IIIIIIIIIIIIIIIIII UNIRAL 1403 N.Research WSol ay Orem,UT 84097 BETTER SOLAR STARTS HERE 800.377.4480 WW W .BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE P­ JIM EXCEPT BLUE RAVEN SOLAR NOR eonoiING&G noiuc SHALL IT BE DISCLOSED IN WHOLE OR U L210 {MEWEnIChLEOAmnc IN PART TO OTHERS OUTSIDE o V MTEMFIRECEAssi=10TION RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SYSTEM OVERVIEW 20% FEWER ATTACHMENTS WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. PARTNAME DESCRIPTION Save time and money on every project:SFM INFINITY requires fewer attachments than rail systems. NABCEP 2 INSTALLS PER DAY TRIMRAIL Structural fronttrim provides aesthetic and aligns modules. CERTIFIED Make two installs per day your new standard.SFM INFINITY has fewer PV INSTALLATION TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. PROFESSIONAL roof attachments,one tool installation,and pre-assembled components Scott Gurney to get you off the roof 40%faster. #PV-011719-015866 TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof.Available for comp shingle or tile. CONTRACTOR: 1 SFM INFINITY 15 Attachments BRS FIELD OFFS MODULE CLIPS Secure modules to TRIMRAIL. 385-498-6700 MICRORAIL Connects modules to SLIDERS.Provides post-install array leveling. BETTER AESTHETICS 74F Install the system with the aesthetics preferred by homeowners, SPLICE Connects and supports modules.Provides east-west bonding. with integrated front trim,trim end caps,dark components,and ATTACHED SPLICE also available. recessed hardware. SLIDER FLASHKIT Roof attachment and flashing.Available for comp shingle and tile. RAIL 20 Attachments MAXIMUM POWER DENSITY 30% LOGISTICS SAVINGS Easily mix module orientations to achieve optimal power density With fewer SKUs and compact components,SFM INFINITY is easier to without incurring the increased bill of materials,labor,and BONDING AND ACCESSORIES attachments required by rail. stock,easier to transport,and easier to lift to the roof.Plus,make more PARTNAME DESCRIPTION efficient use of your vehicle fleet. TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules 164 U N/S BONDING CLAMP Electrically bonds rows of modules • • • • DRAWING BY PLOT DATE: SFM INFINITY REVOLUTIONIZES ROOFTOP SOLAR BENEFITS ACROSS YOUR BUSINESS, PROJECT NUMBER: I DESIGN AND LOGISTICS, THROUGH I ARRAY RRA INSTALLATION AI AND SERVICE. SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ---- SS `4% En SUN � SYSTEM BONDINGGROUNDING '� 19 BLUE RAVED ■ ■ ■ SFM FRAME Sol ■ ■ MICRORAILTM INSTALLATION GUIDE ; PAGE 140rem,UT84097yay 800.377.4480 --——————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————————— WWW.BLUERAVENSOLAR.COM ® CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION o OF BLUE RAVEN SOLAR LLC. NABCEP CERTIFIED PV INSTALLATION PROFESSIONAL Scott Gurney #PV-011719-015866 E-W BONDING PATH: CONTRACTOR: E-W module to module bonding is accomplished BRS FIELD OPS with 2 pre-installed bonding pins which engage 385-498-6700 on the secure side of the MicrorailTM and splice. I I Star Washer is WEEBLUG Single Use Only Single Use Only Alternate method N-S BONDING PATH: TERMINALTOROUE, N-S module to module bonding is Install Conductor and accomplished with bonding clamp with 2 integral torque to the following: TERMINAL TORQUE" TERMINALTOROUE, bonding pins. ;refer also to alternate method) 4-6 AWG: 35in-lbs Install Conductor and Install Conductor and 8 AWG: 25 in-lbs torque to the following: torque to the following: 10-14 AWG:20 in-lbs 4-14 AWG: 35in-lbs 6-14 AWG:7ft-lbs DRAWING BY: LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO LUG DETAIL & TORQUE INFO Ilsco Lay-In Lug (GBL-4DBT) Ilsco Flange Lug (SGB-4) Wiley WEEBLug (6.7) ► 1 PLOT DATE • 10-32 mounting hardware 0 1/4" mounting hardware 0 1/4" mounting hardware _ _ _ � <<- • Torque = 5 ft-lb 0 Torque = 75 in-lb 0 Torque = 10 ft-lb Alternate method • AWG 4-14-Solid or Stranded 0 AWG 4-14-Solid or Stranded 0 AWG 6-14-Solid or Stranded PROJECT NUMBER: TRIMRAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION Trimrail to module bonding is accomplished with SHEET NAME System bonding is accomplished through modules.System grounding accomplished by attaching bonding clamp with integral bonding pin and SPEC SHEET a ground Lug to any module at a Location on the module specified by the module manufacturer. bonding T-bolt. (refer also to alternate method) REVISION PAGE NUMBER ---- SS `4% in SUN UL CODE COMPLIANCE NOTES ' 20 BLUE RAVE ANN SFM FRAME 03 N.Research ■ ■ MICRORAILTM INSTALLATION GUIDI ; PAGE 140rem,UT84097Vay 800.377.4480 _____________________________________________________________________________________________________________________________________________ WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN SHALL NBE SYSTEM LEVEL FIRE CLASSIFICATION USED OROINE THEABENDFIT OF AO ONE EXCEPT BLUE RAVEN SOLAR NOR The system fire class rating requires installation in the manners specified in the performance is inherent in the SFM design,and no additional mitigation measures SHALLITBTTOOT DISCLOSED IN OUTSIDE RECIPIENTS Y 9 q P p 9 � 9 IN PART TO OTHERS OUTSIDE SUNFRAME MICRORAIL SFM Installation Guide. SFM has been classified to are re uired.The fire classification rating is valid for an roof itch.There is no IN CI NNEC ION WITH THE ORGANIZATION, D q 9 Y P IN CONNECTION WITH THE SALE AND the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain WITHOUT THEWRITT N EQUIPMENT, Y P q 9 WITHOUT THE WRITTEN PERMISSION incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILT"'components shall OF BLUE RAVEN SOLAR LLC. B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. in conjunction with type 1 and type 2 modules. Class A, B & C system level fire NABCEP CERTIFIED Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required PV INSTALLATION PROFESSIONAL T e 1 and T e 2 Stee Slo e & Low Sloe Class A, B & C East-West Landsca e OR Portrait None Re uired Scott Gurney YP YP P P P P q #PV-011719-015866 CONTRACTOR: OPS UL2703 TEST MODULES B3R 5 4198 6 00 See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sgft • UL2703 Design Load Ratings: a) Downward Pressure — 113 PSF / 5400 Pa b) Upward Pressure — 50 PSF / 2400 Pa c) Down-Slope Load — 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure — 170 PSF / 8000 Pa b) Upward Pressure — 75 PSF / 3500 Pa c) Down-Slope Load — 32.4 PSF / 1550 Pa • Maximum Span = 6ft DRAWING BY: • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 PLOT DATE: • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information PROJECT NUMBER • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ---- SS ■ SUN 1 `4% CERTIFIEDMODULELISTZZ ■ ■ 1SFM FRAME BLUE RAVED ■ ■ ; MICRORAILTM INSTARATION GUIDE 'I PAGE 1403 N.Research Orem,UT84097Vay ______________________________________-_----------------------------------------------------------------------------------------------------- 800.377.4480 W WW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR Aleo P-Series Eco Solargy Orion 1000 &Apollo 1000 LGxxxN2T-A4 IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT ET Solar ET-M672BHxxxTW LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, DNA-120-(BF/MF)26 QlC/QWITHOUT THE WRITTEN PERMISSION DNA-144-(BF/MF)26 Aptos Freedom Forever FF-MP-BBB-370 LGxxxN 2T-B5 K/S1C/S2W)-A5 OF BLUE RAVEN SOLAR LLC. FreeVolt Mono PERC GxxxN CHSM6612P,CHSM6612P/HV,CHSM6612M, GCL GCL-P6 & GCL-M6 Series LGxxxN1K-B6 NABCEP LGxxx(A1C/M1C/M1K/N1C/N1K/01C/01K/ CERTIFIED Astronergy CHSM6612M/HV,CHSM6610M (BL)(BF)/(HF), Hansol TD-AN3,TD-AN4, LG Electronics OAC/OAK)-A6 CHSM72M-HC UB-AN1,UD-AN1 PV INSTALLATION LGxxx(N1C/N1K/N2T/N2W)-E6 PROFESSIONAL AXN6M610T,AXN6P610T, 36M,60M,60P,72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 Scott Gurney Auxin #PV-011719-015866 AXN6M612T&AXN6P612T Heliene 144HC M6 Monofacial/Bifacial Series, LGxxxN2T-J5 144HC M10 SL Bifacial CONTRACTOR: AXlblackpremium 60(35mm), LGxxx(N1K/N1W/N2T/N2W) L5 BRS FIELD OPS AXIpower 60 (35mm), HT Solar HT60-156(M) (NDV) (-F), LGxxx(N1C/01C/01K)-N5 385-498-6700 Axitec AXIpower 72 (40mm), HT 72-156(M/P) LGxxx(N1C/N1K/N2W/Q1C/Q1K)-V5 AXIpremium 60 (35mm), Hyundai KG,MG,TG,RI,RG,TI,MI,HI & KI Series LR4-60(HIB/HIH/HPB/HPH)-xxxM AXIpremium 72 (40mm). HiA-SxxxHG LR4-72(HIH/HPH)-xxxM Boviet BVM6610, ITEK iT,iT-HE & iT-SE Series LR6-60(BP/HBD/HIBD)-xxxM (30mm) BVM6612 Japan Solar JPS-60 &JPS-72 Series LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) BYD P6K & MHK-36 Series LONG LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) CS1(H/K/U/Y)-MS JAP6 60-xxx,JAM 6-60-xxx/SI,JAM 6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) CS3(K/L/U),CS3K-MB-AG,CS3K-(MS/P) xxx,1AP6(k)-72-xxx/4BB,1AP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM Canadian Solar CS3N-MS,CS3U-MB-AG,CS3U-(MS/P),CS3W JAP6(k)-60-xxx/4BB,JAP60SYY-xxx/ZZ, (35mm) CS5A-M,CS6(K/U),CS6K-(M/P),CS6K-MS JA Solar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) CS6P-(M/P),CS6U-(M/P),CS6V-M,CS6X-P JAM6(k)-60-xxx/ZZ,JAM60SYY-xxx/ZZ. Mission Solar Energy MSE Series i.YY:01,02,03,09,10 CentrosolarAmerica C-Series & E-Series ii.ZZ:SC,PR,BP,HiT,IB,MW,MR Mitsubishi MJE & MLE Series CT2xxMxx-01,CT2xxPxx-01, JKM &JKMS Series Neo Solar Power Co. D6M & D6P Series CertainTeed CTxxxMxx-02,CTxxxM-03, CTxxxMxx-04,CTxxxHC11-04 Jinko Eagle JKMxxxM JKMxxxM-72HL-V Dehui DH-60M Kyocera KU Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID SHEET NAME • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID SPEC SHEETS • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information REVISION PAGE NUMBER 0 SS ■ SUN 1 `4% CERTIFIEDMODULELIST1Z3■ ■ 1SFM FRAME BLUE RAVED ■ ■ 03 N.Research; MICRORAILTM INSTARATION GUIDE 'I PAGE 14Orem,UT84097Vay ______________________________________-_----------------------------------------------------------------------------------------------------- 800.377.4480 W WW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION Manufacture Module Model/Series Manufacture Module Model/Series Manufacture Module Model/Series HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR EVPVxxx(H/K/PK), TwinPeak Series Suniva MV Series & Optimus Series IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT VBHNxxxSA15 & SA16, TwinPeak 2 Series A-Series A400-BLK,SPR-MAX3-XXX-R, IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, SunPower VBHNxxxSA17 & SA18, TwinPeak 2 BLK2 Series X-Series,E-Series & P-Series WITHOUT THE WRITTEN PERMISSION REC Solar(cont.) OF BLUE RAVEN SOLAR LLC. Panasonic VBHNxxxSA17(E/G) & SA18E, TwinPeak 2S(M)72(XV) Suntech STP,STPXXXS-B60/Wnhb VBHNxxxKA01 & KA03 & KA04, TwinPeak 3 Series (38mm) TP572,TP596,TP654,TP660, NABCEP VBHNxxxZA01,VBHNxxxZA02, TP4(Black) Talesun TP672,Hipor M,Smart CERTIFIED V13HNxxxZA03,VI3HNxxxZA04 Renesola Vitrus2 Series & 156 Series SC,SC B,SC B1,SC B2 PV INSTALLATION Peimar SGxxxM FB/BF Risen RSM72-6 MDG M ,RSM60-6 Tesla PROFESSIONAL ( ) ( ) ( ) TxxxH,TxxxS Scott Gurney Phono Solar PS-60,PS-72 SEG Solar SEG-xxx-BMD-HV PA05,PD05,DD05,DE06,DD06,PE06, #PV-011719-015866 Prism Solar P72 Series SEG-xxx-BMD-TB Trina PD14,PE14,DD14,DE09.05,DE14,DE15, CONTRACTOR: S-Energy SN72 & SN60 Series 40mm BRS FIELD OPS Plus,Pro,Peak,G3,G4,G5,G6(+),G7,G8(+) 9Y ( ) PE15H 385-498-6700 Pro,Peak L-G2,L-G4,L-G5,L-G6,L-G7 Seraphim SEG-6 & SRP-6 Series UP-MxxxP(-B), O.PEAK DUO BLK-G6+ Upsolar Sharp NU-SA& NU-SC Series UP-MxxxM(-B) O.PEAK DUO BLK-G6+/TS SLA, SLG,BC Series & SlLxxx(BL/NL/NT/HL/ D7MxxxH7A,D7(M/K)xxxH8A O.PEAK DUO (BLK)-G8(+) Silfab ML/BK/NX/NU/HC) United Renewable Energy FAKxxx(C8G/E8G),FAMxxxE7G-BB O.Cells O.PEAK DUO L-G8.3/BFF Solarever USA SE-166*83-xxxM-120N (URE) FAMxxxE8G(-BB) O.PEAK DUO (BLK) ML-G9(+) F13MxxxMFG-BB PowerXT-xxxR-(AC/PD/BD) _ O.PEAK DUO XL-G9/G9.2/G9.3 Eldora, Solaria PowerXT-xxxC-PD O.PEAK DUO (BLK) ML-G10(+) PowerXT-xxxR-PM (AC) Vikram Solivo, O.PEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Sunmodule Protect, Somera O.PEAK DUO BLK ML-G10+/t SolarWorld Sunmodule Plus Waaree AC &Adiya Series Alpha (72) (Black) (Pure) SS-M-360 to 390 Series, Winaico WST&WSP Series RECxxxAA PURE-R SS-M-390 to 400 Series, Yingli YGE &YLM Series RECxxxNP3 Black Sonali SS-M-440 to 460 Series, ZN Shine ZXM6-72, ZXM6-NH144-166 2094 N-Peak(Black) - REC Solar SS-M-430 to 460 BiFacial Series, N-Peak 2 (Black) SS 230-265 PEAK Energy Series SunEdison F-Series,R Series & FLEX FXS Series PEAK Energy BLK2 Series PEAK Energy 72 Series • Unless otherwise noted,all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID SHEET NAME • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID SPEC SHEETS • Please see the SFM UL2703 Construction Data Report at Unirac.com to ensure the exact solar module selected is approved for use with SFM REVISION PAGE NUMBER • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 12 for further information 0 SS Intertek Lntertek BLUE RAVEN AUTHORIZATION TO MARK AUTHORIZATION TO MARK Total Quality.Assured. Total Quality.Assured. 1403 N.Research Way Orem,UT 84097 This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) 800.377.4480 Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing WWW.BLUERAVENSOLAR.COM Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing CONFIDENTIAL-THE INFORMATION HEREIN BE Report. Report. USED OROTHE ABENEFIT OFA SHALL NYONE EXCEPT BLUE RAVEN SOLAR NOR This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be SHALL IT BE DISCLOSED IN WHOLE OR applied only at the location of the Part Authorized To Apply Mark. applied only at the location of the Part Authorized To Apply Mark. N PART TO OTHERS OUTSIDE pP Y Y pp Y pp Y Y pp Y RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: OF BLUE RAVEN SOLAR LLC. 1411 Broadway Blvd NE 1411 Broadway Blvd NE NABCEP Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: CERTIFIED Country: USA Country: Country: USA Country: PV INSTALLATION Party Authorized To Apply Mark: Same as Manufacturer n' Party Authorized To Apply Mark: Same as Manufacturer PROFESSIONAL Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA 1/ Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA / Scott Gurney Control Number: 5003705 Authorized by: 'I`\ ac Control Number: 5014989 Authorized by: may #PV-011719-015866 for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager CONTRACTOR: BRS FIELD OPS 385-498-6700 C US C US 4areo tfareo Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Standard(s): Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM SHEET NAME: ATM for Report 102393982LAX-002 Page 1 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued: 17-May-2023 SPEC SHEETS ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory REVISION: PAGE NUMBER: 0 SS Intertek Intertek BLUE RAVEN AUTHORIZATION TO MARK AUTHORIZATION TO MARK Total Quality.Assured. Total Quality.Assured. 1403 N.Research Way Orem,UT 84097 7.4480 This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) 8 WWW.BLUERAVRAVENSOSOLAR.COM Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE Report. Report. USED FOR THE BENEFIT OF ANYONE EXCEPT BLUE RAVEN SOLAR NOR This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE applied only at the location of the Party Authorized To Apply Mark. applied only at the location of the Party Authorized To Apply Mark. RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION Applicant: Unirac, Inc Manufacturer: Applicant: Unirac, Inc Manufacturer: OF BLUE RAVEN SOLAR LLC. 1411 Broadway Blvd NE 1411 Broadway Blvd NE NABCEP Address: Albuquerque, NM 87102 Address: Address: Albuquerque, NM 87102 Address: CERTIFIED Country: USA Country: Country: USA Country: PV INSTALLATION Party Authorized To Apply Mark: Same as Manufacturer Party Authorized To Apply Mark: Same as Manufacturer PROFESSIONAL Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA Report Issuing Office: Intertek Testing Services NA, Inc., Lake Forest, CA �Q Scott Gurney Control Number: 5019851 Authorized by: � ,,,,,/ Control Number: 5021866 Authorized by: ,Qyy�'y p�. #PV-011719-015866 for L. Matthew Snyder, Certification Manager for L. Matthew Snyder, Certification Manager CONTRACTOR: BRS FIELD OPS 385-498-6700 C US C us UdTEO traTeo Intertek Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat- Mounting Systems, Mounting Devices, Clamping/Retention Devices,and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] Standard(s): Plate Photovoltaic Modules and Panels[UL 2703:2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories[CSA TIL No.A-40:2020] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No.A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Product: Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2023MAY10 Brand Name: Unirac Brand Name: Unirac Models: Unirac SFM Models: Unirac SFM SHEET NAME: ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued: 17-May-2023 ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued: 17-May-2023 SPEC SHEETS ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory REVISION: PAGE NUMBER: 0 SS ntertek Listing Constructional Data Report (CDR) �ntertek Listing Constructional Data Report (CDR) BLUE RAVEN Total Quality.Assured. Total Quality.Assured. 1403 N.Research Way Orem,UT 84097 1.0 Reference and Address 1.0 Reference and Address Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 Report Number 102393982LAX-002 Original 11-Apr-2016 Revised: 5-Oct-2022 WWW.BLUERAV 800.377.4480 .4480LAR.COM Email CONFIDENTIAL-THE INFORMATION Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use HEREIN CONTAINED SHALL NOT BE with Flat-Plate Photovoltaic Modules and Panels rUL 2703:2015 Ed.1+R:24Mar2021] EXCEPT BLUE RAVEN SOL USED FOR THE BENEFIT OL AAR NE NOR Standard(s) ` R SHALL IT BE DISCLOSED IN WHOLE OR PV Module and Panel RackingMounting System and Accessories CSA TIL No. A-40:2020 N PARTT ORGANIZATION, EXCEPT 9 Y � � RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, Applicant Unirac, Inc Manufacturer 2 WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. 1411 Broadway Blvd NE Address Albuquerque, NM 87102 Address NABCEP Country USA Country Contact Klaus Nicolaedis Contact CERTIFIED Todd Ganshaw PV INSTALLATION 505-462-2190 PROFESSIONAL Phone 505-843-1418 Phone Scott Gurney #PV-011719-015866 FAX NA FAX klaus.nicolaedis@unirac.com CONTRACTOR: Email toddg@unirac.com Email BRS FIELD OPS 385-498-6700 Manufacturer 3 Manufacturer 4 Address Address Country Country Contact Contact Phone Phone FAX FAX Email Email Manufacturer 5 Address DRAWING BY: Country Contact PLOT DATE: Phone FAX PROJECT NUMBER: Page 1 of 138 Page 2 of 138 This report is for the exclusive use of Inlenek's Client and is provided pursuant to the agreement between Intertek and its Client Intertek's responstblty and This report 4 for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client Intertek's respons+W�ty and SHEET NAME: liability are limited to the terms and conditions of the agreement Inlertek assumes no hablrty to any party other than to the Client in accordance with the liabt•ty are limited to the terms and cond ons of the agreement Intertek assumes no Itat*rty to any party other than to the Client in accordance with the agreement for any loss,expense or damage occasioned by the use of this report Only the Client is authorized to permit eop'Mg or distribution of this report and agreement.for an toss,expense or dam occasioned the use of this r y age by sport Only the Client.s authorized to permit coping or distribution of the report and SPEC H E ET then only in its entirety Any use of the Wertek name or one of its marks for the sale or advertisement of the tested material. product or service must first be then only in its entirety Any use of the Intenek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek The observabons and test results in this report are relevant only to the sample tested This report by dsell does not empty that the approved in wnbng by Intertek The observations and test results in this report are relevant only to the sample tested This report by ttsetl does not imply that the material product,or service is or has ever been under an Intertek cenifrcawn program material product,or service is or has ever been under an Intertek certifrcabon program REVISION: PAGE NUMBER: SS Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-Apr-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-Apr-2016 Unirac, Inc Revised: 5-Oct-2022 Unirac, Inc Revised: 5-Oct-2022 2.0 Product Description 2.0 Product Description BLUE RAVEN Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Models Unirac SFM 1403 N.Research Way Brand name Unirac Model Similarity NA Orem,UT84097 800.377.4480 The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic WWW.BLUERAVENSOLAR.COM Rack Mounting System. This system is designed to provide bonding and grounding to Fuse Rating: 30A CONFIDENTIAL-THE INFORMATION photovoltaic modules. The mounting s employs anodized or mill finish aluminum brackets HEREIN CONTAINED SHALL NOT BE p 9 stem YUSED FOR THE BENEFIT OF ANYONE that are roof mounted using the slider, outlined in section 4 of this report. There are no rails Module Orientation: Portrait or Landscape EXCEPT BLUE RAVEN SOLAR NOR within this product, whereas the 3" Micro Rail, Floating Splice, and 9"Attached Splice Maximum Module Size: 17.98 ft2 SHALL IT BE DISCLOSED IN WHOLE OR p 9 p p IN PART TO OTHERS OUTSIDE electrically bond the modules together forming the path to ground. UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope RECIPIENTS ORGANIZATION,EXCEPT Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading WITHOUT THE WRITTEN PERMISSION OF BLUE RAVEN SOLAR LLC. with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate Increased size ML test: the anodized coating of the photovoltaic module frame (at bottom flange)to contact the metal, Maximum Module Size: 22.3 ft2 NABCEP creating a bonded connection from module to module. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope Description LG355S2W-A5 I CERTIFIED The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. 9 9 Y PV INSTALLATION National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Mounting configuration: Four mountings on each long side of panel with the longest span of 24" PROFESSIONAL Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope Scott Gurney revision in effect in the jurisdiction in which the project resides. Any local electrical codes must LG395N2W-A5, #PV-011719-015866 be adhered in addition to the national electrical codes. The GroundingLug is secured to the LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. g CONTRACTOR: photovoltaic module, torqued in accordance with the installation manual provided in this Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" BRS FIELD OPS document. IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift 385-498-6700 Other optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 which requires a minimum of 2 micro-inverters mounted to the same rail, and using the same Certifications, & Increase SFM System UL2703 Module Size: engage cable. Maximum Module Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: -Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roof's surface See section 7.0 illustractions# 1, 1 a and 1 b for a complete list of PV modules evaluated with DRAWING BY: these racking systems PLOT DATE: Other Ratings NA PROJECT NUMBER: SHEET NAME: SPEC SHEET REVISION: PAGE NUMBER: ED 16.3.15(1-Jul-2022)Mandatory ED 16.3.15(1-Jul-2022)Mandatory ———— SS Do M u S Domus Structural Engineering, LLC �7 TR1) CTURA1, P.O. Box560 Broomfield, CO 80038 -�- N Ci T NEER T N G T. LC 530-864-7055 projects@domusstruc.com May 25,2023 To: Blue Raven Solar 1403 North Research Way,Building J Orem,UT.84097 Subject: Certification Letter Quie Residence 1475 Creek Park Ln Minneapolis,MN.55432 To Whom It May Concern, A jobsite observation of the condition of the existing framing system was performed by an audit team of Blue Raven Solar as a request from Domus Structural Engineering.All review is based on these observations and the design criteria listed below and only deemed valid if provided information is true and accurate. On the above referenced project,the roof structural framing has been reviewed for additional loading due to the installation of the solar PV addition to the roof.The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements.The observed roof framing is described below.If field conditions differ,contractor to notify engineer prior to starting construction. The roof structures of(MP1&2)consist of composition shingle on roof plywood that is supported by pre-manufactured trusses that are spaced at @ 24"o.c..The top chords,sloped at 23 degrees,are 2x4 sections,the bottom chords are 2x4 sections and the web members are 2x4 sections.The truss members are connected by steel gusset plates.The max unsupported projected horizontal top chord span is approximately 6'-0". The existing roof framing systems of(MP1&2)are judged to be adequate to withstand the loading imposed by the installation of the solar panels.No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.for landscape and 24"o.c.for portrait orientation,with a staggered pattern to ensure proper distribution of loads. The scope of this report is strictly limited to an evaluation of the fastener attachment,underlying framing and supporting structure only.The attachment's to the existing structure are required to be in a staggered pattern to ensure proper distribution of loading.All panels,racking and hardware shall be installed per manufacturer specifications and within specified design limitations.All waterproofing shall be provided by the manufacturer. Domus Structural Engineering assumes no responsibility for misuse or improper installation of the solar PV panels or racking. Note:Seismic check is not required since Ss<.4g and Seismic Design Category(SDC)<B Design Criteria: ```Z+ l f r' • Applicable Codes=2020 Minnesota Building Code,ASCE 7-16 C,,N CA/ • Roof Dead Load=7 psf(MP1&2) ':� • Roof Live Load=20 psf f IC D • Wind Speed=115 mph(Vult),Exposure C _ I • Ground Snow Load=50 psf - Roof Snow Load=35 psf ENG E • Attachment:1-5/16 dia.lag screw with 2.5 inch min.embedment — depth,at spacing shown above. 52823 01 Please contact me with any further questions or concerns regarding this project. 'r Ofi MIXA '�t�f19141t�` Sincerely, I hereby certify that this plan,specification or reportwas prepared by me Digitally signed by or under my direct supervision and that I am a duly Licensed Professional John A.Calvert Engineer under the laws of the State of Minnesota.John A.Calvert, Date:2023.05.25 John Calvert,P.E. License No.52823 Expiration Date:30-June-2024 Project Engineer 17:10:49-06'00' Quie Minneapolis MN 1 Do m u S Domus Structural Engineering, LLC -c7 TRi) CTURA 1, P.O. Box560 Broomfield, CO 80038 E N G I N E F. R T N G T_ T. t: 530-864-7055 projects@domusstruc.com Gravity Loading Roof Snow Load Calculations pg=Ground Snow Load= 50.0 psf pf=0.7 Ce Cf I pg (ASCE7-Eq 7-1) Ce=Exposure Factor= 1 (ASCE7-Table 7-2) Cf=Thermal Factor= 1 (ASCE7-Table 7-3) 1=Importance Factor= 1 pf=Flat Roof Snow Load= 35.0 psf p5=CSpf (ASCE7-Eq 7-2) Cs=Slope Factor= 1 p,=Sloped Roof Snow Load= 35.0 psf PV Dead Load=3 psf(Per Blue Raven Solar) DL Adjusted to 23 Degree Slope 3.26 psf PV System Weight Weight of PV System(Per Blue Raven Solar) 3.0 psf X Standoff Spacing= 2.00 ft Y Standoff Spacing= 6.08 ft Standoff Tributary Area= 12.17 sft Point Loads of Standoffs 37 lb Note:PV standoffs are staggered to ensure proper distribution of loading Roof Live Load=20 psf Note:Roof live load is removed in area's covered by PV array. Roof Dead Load(MP1&2) Composition Shingle 4.00 Roof Plywood 2.00 2x4 Top Chords @ 24"o.c. 0.73 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.27 Total Roof DL(MP1&2) 7.0 psf DL Adjusted to 23 Degree Slope 7.6 psf Quie Minneapolis MN 2 Do M u S Domus Structural Engineering, LLC -S- T R U C T U R A L P.O. Box 560 Broomfield, CO 80038 N G I N E E R I n 6 1 T C 530-864-7055 projects@domusstruc.com Wind Calculations Per ASCE 7-16 Components and Cladding Input Variables Wind Speed 115 mph Exposure Category C Roof Shape Hip Roof Roof Slope 23 degrees Mean Roof Height 20 ft Effective Wind Area 21.3 ft Ground Elevation 0 ft Design Wind Pressure Calculations qh=0.00256*Kz*Kzt*Kd*Ke*V12 (Eq.26.10-1) Kz(Exposure Coefficient)=0.90 (Table 30.3-1) Kzl(topographic factor)= 1.00 (Fig.26.8-1) Kd(Wind Directionality Factor)= 0.85 (Table 26.6-1) Ke(Ground Elevation Factor)= 1.00 V(Design Wind Speed)= 115 mph (Fig.26.5-1A) Risk Category= II (Table 1.5-1) qh= 25.95 Standoff Uplift Calculations-Portrait Zone 1 Zone 2 Zone 3 Positive ya= 0.77 0.80 0.80 0.77 GCp= -1.35 -2.00 -2.00 0.67 (Fig.30.3) Uplift Pressure= -27.0 psf -41.5 psf -41.5 psf 13.3 psf (Eq.29.4-7) ASD Uplift Pressure= -16.2 psf -24.9 psf -24.9 psf 9.6 psf X Standoff Spacing= 2.00 2.00 1.33 Y Standoff Spacing= 6.08 3.04166667 3.04166667 Tributary Area= 12.17 6.08 4.06 Dead Load on attachment= 37 lb 18 lb 12 lb Footing Uplift(0.6D+0.6W)_ -175lb -141 lb -94lb Standoff Uplift Calculations-Landscape Zone 1 Zone 2 Zone 3 Positive ya= 0.75 0.80 0.80 0.75 GCp= -1.31 -2.00 -2.00 0.64 (Fig.30.3) Uplift Pressure= -25.6 psf -41.5 psf -41.5 psf 12.5 psf (Eq.29.4-7) ASD Uplift Pressure(0.6W)= -15.3 psf -24.9 psf -24.9 psf 9.6 psf X Standoff Spacing= 4.00 4.00 2.67 Y Standoff Spacing= 3.50 1.75 1.75 Tributary Area= 14.00 7.00 4.67 Dead Load on attachment= 42.00 21.00 14.00 Footing Uplift(0.6D+0.6W)_ -190 lb -162lb -108lb Standoff Uplift Check Maximum Design Uplift=-190 lb Standoff Uplift Capacity =450 lb 450 lb capacity>190 lb demand Therefore,OK Fastener Capacity Check I Fastener= 1-5/16"dia.lag Number of Fasteners= 1 Embedment Depth=2.5 Pullout Capacity Per Inch= 250 lb Fastener Capacity=625 lb w/F.S.of 1.5&DOL of 1.6=667 lb 667.2 lb capacity>190 lb demand Therefore,OK Quie Minneapolis MN 3 Do M t? S Domus Structural Engineering, LLC �7 TR1) CTURA1, P.O. Box560 Broomfield, CO 80038 -�- N Ci T NEER T N G T T. U. 530-864-7055 projects@domusstruc.com Framing Check (MP1&2) PASS w=92plf Dead Load 7.6 psf PV Load 3.3 psf Snow Load 35.0 psf 2x4 Top Chords @ 24"o.c. ZS, O Governing Load Combo=DL+SL CE Member Span=6'-0" Total Load 45.9 psf Member Properties Member Size S(in A3) 1(in A4) Lumber Sp/Gr Member Spacing 2x4 3.06 5.36 DF#2 @ 24"o.c. F = Check Bending Stress Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 900 x 1.15 x 1.5 x 1.15 Allowed Bending Stress=1785.3 psi Maximum Moment = (wLA2)/8 = 412.7724 ft# = 4953.269 in# Actual Bending Stress=(Maximum Moment)/S =1617.4 psi Allowed>Actual--90.6%Stressed -- Therefore,OK Check Deflection Allowed Deflection(Total Load) = U180 (E=1600000 psi Per NDS) = 0.4 in Deflection Criteria Based on = Continuous Span Actual Deflection(Total Load) _ (w'LA4)/(185'E'I) = 0.130 in = U554 > L/180 Therefore OK Allowed Deflection(Live Load) = U240 0.3 in Actual Deflection(Live Load) _ (w'LA4)/(185'E'I) 0.099 in L/728 > L/240 Therefore OK Check Shear _ Member Area=5.3 inA2 Fv(psi)= 180 psi (NDS Table 4A) Allowed Shear = Fv'A = 945 lb Max Shear(V)=w L/2 = 275 lb Allowed>Actual--29.2%Stressed -- Therefore,OK Quie Minneapolis MN 4 n M us Domus Structural Engineering, LLC J TR1) CTURAL P.O. Box560 -�: N G 1 NEER i N G 1. 1. C. Broomfield, CO 80038 530-864-7055 projects@domusstruc.com Appendix A:General Notes GENERAL • The contractor shall verify all dimensions,property setbacks,AHJ/HOA CC&R's,elevations and site conditions before starting work and shall notify Domus Structural Engineering,LLC of any discrepancies. • All report conclusions represent Domus Structural Engineering,LLC's best professional judgment based upon industry standards. • Resolve any conflicts on the drawings with Domus Structural Engineering,LLC before proceeding with construction. • The design criteria used for this project&listed on the first page of the report is based on the engineers best judgement and/or provided by the ATC council.AHJ specific requests may differ.Please contact our team if the design criteria needs to be modified. • A site visit was not physically conducted by Domus Structural Engineering,LLC.The accompanying calculations and certification are provided with the understanding that the site building and construction standards meet an acceptable level of industry standards.It shall be the contractors responsibility to identify any irregularities such as inconsistent framing conditions,water damage,fire damage,cracked,split or noticeably deflecting framing members. • Domus Structural Engineering,LLC is not responsible for enforcing safety measures or regulations.The contractor shall design,construct,and maintain all safety devices including shoring and bracing,and shall be solely responsible for conforming to all local,state and federal safety and health standards,laws and regulations.The contractor shall take necessary precautions to maintain and insure the integrity of the structure during construction.If a lawsuit is filed by one of the contractor's or subcontractor's employees,or any one else,the contractor will indemnify,defend and hold the owner and Domus Structural Engineering,LLC harmless of any and all such claims. • Any and all waterproofing shall be provided by the contractor.Domus Structural Engineering,LLC is not responsible for waterproofing. • All hardware shall be installed per manufacturer specifications and within specified design limitations.Domus Structural Engineering,LLC assumes no responsibility for incorrectly installed hardware or hardware installed outside of the manfacturer specifications. USER RELIANCE Domus Structural Engineering,LLC was engaged by Blue Raven Solar(Client)to perform this assessment.This report and the information therein,are for the exclusive use of the Client.This report has no other purpose and shall not be relied upon, or used,by any other person or entity without the written consent of Dous Structural Engineering,LLC.Third parties that obtain this report,or the information within shall have no rights of recourse or recovery against Domus Structural Engineering,LLC,it's officers or employees. ROOF MOUNTED ARRAYS • If an analysis of a supporting stucture is included in our scope of work,the structural assessment only applies to the section of the roof that is directly supporting the proposed solar PV system. • No structural members can be cut for conduit,etc.,unless specifically shown.Obtain prior written approval for installation of any additional conduit,etc. • It is assumed that a standard quality of construction care was used to construct the original building.It shall be the contractors responsibility to field verify any and all framing member supporting the proposed PV array are in adequate condition.The contractor shall field inspect for sub-standard construction means,signs of dry rot,mold,fire damage,etc.and notify engineer if any compromised material is found on site prior to starting construction. • It is assumed that there have been no additional loads(HVAC or MEP equipment,additional layers of roofing,etc)added to the building over the course of the structures histroy.The contractor and/or client shall verify this with the property owner and notify Domus Structural Engineering,LLC if additional load has been added to the structure already. • Flexible utility connections must be used at any building seismic joint. • Care should be taken to ensure that PV arrays do not preclude drainage of rain water. • Unless otherwise noted,construction material shall be evenly distributed if placed on framed floors or roofs.Loads shall not exceed the allowable loading for the supporting members and their connections. • All lags orwood screws at the roof shall be stainless steel and installed withing the middle 1/3 of the dimensional width of the framing members. • All fasteners shall be a minimum of 6"away from any truss panel or hinge joints,truss plates and/or member ends.Field verify location of fasteners prior to starting construction.All fasteners shall be pre-drilled to avoid splitting existing lumber. • Domus Structural Engineering,LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array nor any damage to downslope decks,roofs,walkways,landscaping,automobiles,pets,people,etc..If snow guards are requested by the customer,notify Domus Structural Engineering,LLC. Quie Minneapolis MN 5