HomeMy WebLinkAboutRonald Long Plans and Specs DIRECTORY OF PAGES SCOPE OF WORK 74349 PV-1 PROJECT SUMMARY THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- PV 2 SITE PLAN N INTERACTIVE PV SYSTEM.PV MODULES WILL BE MOUNTED ALL USING A PREENGINEERED MOUNTING SYSTEM.THE MODULES PV-3 SINGLE-LINE DIAGRAM WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER ENERGY 67th Ave NE 67th Ave NE INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY � .;oi_A PV-4 PV SAFETY LABELS USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING PV-5.1-2 ATTACHMENT PLANS JURISDICTION. PV-6 ATTACHMENT DETAILS THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE 1264 ENERGY LANE PV-7 FIRE SAFETY PLAN DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO ST PAUL, MN 55108 DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND 800 620-3370 ANCHOR DATASHEET REGULATIONS.THE DOCUMENT SHALL NOT BE RELIED UPON AS ARRAY WIRING BOX DATASHEETS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS.THE SYSTEM SHALL COMPLY WITH ALL DISCONNECT DATASHEETS MANUFACTURERS INSTALLATION INSTRUCTIONS,AS WELL AS X INVERTER DATASHEET ALL APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE p INTERPRETED IN A WAY THAT OVERRIDES THEM.CONTRACTOR w MODULE DATASHEET IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. 0- MOUNTING SYSTEM DATASHEET Q MOUNTING SYSTEM ENGINEERING LETTER SYSTEM DETAILS UL 2703 CLASS A FIRE CERTIFICATION NEW GRID-INTERACTIVE CV DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO C� UL 2703 GROUNDING AND BONDING CERTIFICATION ENERGY STORAGE (D Z � PROJECT DETAILS DC RATING OF SYSTEM 7.56KW O LLJ LC-) • • ' Map data 0202? AC OUTPUT RATINGS 5.67KW,23.6A (n J > Z PROPERTY OWNER RONALD K LONG Y Q INVERTER(S) 18 X ENPHASE IQ7X-96-2-US _ PROPERTY ADDRESS 1010 67TH AVE NE,FRIDLEY,MN 55432 1 PARCEL MODULE(S) 18 X REC SOLAR REC420AAPURE-R APN 13-30-24-23-0069 SCALE: NTS Q PV-1 (2)BRANCH OF 9 IQ7X-96-2-US Uj Q C0Uj ZONING RESIDENTIAL ARRAY WIRING MICROINVERTERS Z O Q USE AND OCCUPANCY ONE-OR TWO-FAMILY DWELLING CLASSIFICATION GROUP(GROUP R3) INTERCONNECTION DETAILS �_ o AHJ CITY OF FRIDLEY N 51C POINT OF NEW SUPPLY SIDE AC CONNECTION UTILITY COMPANY XCEL ENERGY INTERCONNECTION PER NEC 705.11 0 a METER SERIAL NUMBER 94448812 UTILITY SERVICE 120/240V 10 ELECTRICAL CODE 2020 NEC NFPA 70 � a Spring INSIDE PANELBOARD FUSED EATON DG222NRB ( ) ❑ ❑ I DISCONNECT,2-POLE,60A,240VAC FIRE CODE 2018 IFC Lake Park Mounds View _ 2020 MN BUILDING CODE SITE DESIGN PARAMETERS OTHER BUILDING CODES 2020 MN RESIDENTIAL CODE 47 ASHRAE EXTREME LOW -26°C(-15°F) Account: 51-6117954-6 2020 MN PLUMBING CODE 2020 MN MECHANICAL CODE ASHRAE 2%HIGH 32°C(90°F) Meter: 94448812 Fridley RICE CREEK CLIMATE DATA SOURCE ANOKA COUNTY AIRPORT Premise: 303404282 Brooklyn Shoreview WIND(ASCE 7-16) 109 MPH,EXPOSURE CATEGORY B, Case: 05469040 y z5z RISK CATEGORY II 65 LONG LAKE 10 ORTH Center GROUND SNOW LOAD 50 PSF ® NSBRU INNSBRUCK New Brighton PROJECT SUMMARY SK'+'A'AY DOWNTOWN 47 DOC ID:90516C-1 Hilltop DATE:5/25/23 Columbia E Arden Hills CREATOR:A.F. Heights Map data©2023 Google REVIEWER:B.W. 2 LOCALE REVISIONS PV-1 SCALE: NTS PV-1 PROJECT INFORMATION 74349 O CONTRACTOR NAME E(800) ENERGY SOLAR CONTRACTOR PHONE 620-3370 ��� ALL ENERGY GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE 6 7T H AVE N E ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MIN.WORKING CLEARANCES PER NEC 110.26. 1264 ENERGY LANE 2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE ST PAUL, MN 55108 PROVIDED TO ALL XCEL ENERGY EQUIPMENT. (800)620-3370 3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 4 EQUIPMENT,CABLES,ADDITIONAL CONDUITS, RACEWAYS,AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. ALL EXPOSED PV ROOFTOP CONDUCTORS NOT UNDER 5 THE ARRAY SHALL BE PROTECTED BY A RACEWAY WITH A LISTED JUNCTION BOX AT BOTH ENDS AND COMPLY WITH NEC 690.31(A). W LLI CN 6 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS Z - WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A C/) z 1_0 RAINTIGHT FIT,PER NEC 358.42. >_ 0 Uj LC7 SITE SHALL MEET NESC CLEARANCE REQUIREMENTS z o (N)PROPOSED ROOF-MOUNTED PV ARRAY.6/12(26.6°) LLJ Q O J OSLOPED ROOF,(10)REC SOLAR REC420AA PURE-R — z O MODULES(BLACK FRAME,BLACK BACKSHEET),178° Q' O AZIMUTH O (N)PROPOSED ROOF-MOUNTED PV ARRAY.6/12(26.6°) LL O2 SLOPED ROOF,(8)REC SOLAR REC420AA PURE-R (D MODULES(BLACK FRAME,BLACK BACKSHEET),88° ® AZIMUTH 3O (E)MAIN SERVICE PANEL(MSP),INDOOR (N)VISIBLE-OPEN TYPE,LOCKABLE,READILY ® O4 ACCESSIBLE,LABELED UTILITY PV DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER(SW1), OUTDOOR Account: 51-6117954-6 1 2 O (N)AC COMBINER(Cl),OUTDOOR Meter: 94448812 ® ® ® 6O (E)UTILITY METER,OUTDOOR Premise: 303404282 3 O (N)PV SERVICE DISCONNECT(SW2),OUTDOOR Case: 05469040 ® (N)READILY ACCESSIBLE PRODUCTION METER 4 gO LOCATED WITHIN 10 FT OF UTILITY METER(M2), OUTDOOR 5 (N)TRANSITION BOX,OUTDOOR,OUTPUT CIRCUIT SITE PLAN 7 O CONDUCTORS ROUGH E CONDUIT E INTERIOR OF THE BUILDING THROUGH H N E DOC ID:90516C-1 ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE DATE:5/25/23 8 9 INTERIOR OF THE BUILDING,AND WHERE POSSIBLE, 10 ALONG THE BOTTOM OF LOAD BEARING MEMBERS.NO CREATOR:A.F. 14t a p i at '_ CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. REVIEWER:B.W. DISTANCE TO NEAREST CROSS STREET FROM ADDRESS 1 SITE PLAN REVISIONS 384' gR00KVIEW DRIVE NORTHEAST Pv-2 SCALE: 1" = 10' PV-2 74349 PM1-18 j+—; + PV MODULE MODULES GENERAL ELECTRICAL 420W MICROINVERTER REF. QTY. MAKE AND MODEL PMAX PTC ISC INIP VOC VMP TEMP.COEFF.OF VOC FUSE RATING NOTES PM1-18 18 REC SOLAR REC420AA PURE-R 420W 402W 8.89A 8.40A 59AV 50.OV -0.1408VPC(-0.24%FC) 25A 0A INVERTERS DISCONNECTS UTILITY HAS 24-HR UNRESTRICTED ALLI I Q Q QTY AC RATED MAX OUTPUT MAX INPUT MAX INPUT CEC WEIGHTED REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE ACCESS TO ALL PHOTOVOLTAIC REF. MAKE AND MODEL GROUND 1 VOLTAGE POWER CURRENT CURRENT VOLTAGE EFFICIENCY SW1 1 EATON DG221URBOR EQUIV. 30A 240VAC SYSTEM COMPONENTS LOCATED AT ENERGY 9IN 19IN 5QQ6 11-18 18 ENPHASE 240V NOT SOLIDLY 315W 1.31A 10.OA 80V 97.5% SW2 1 EATONDG222NRBOREQUIV. 60A 240VAC THE SERVICE ENTRANCE. �sR CH �R CH IQ7X-96-2-US GROUNDED II + III + /7\ OCPDS PASS-THRU BOXES AND COMBINERS CONDUCTORS EXPOSED TO r-- REF. QTY. RATED CURRENT MAX VOLTAGE REF.QTY MAKE MODEL RATED CURRENT MAX RATED VOLTAGE SUNLIGHT SHALL BE LISTED AS — — CB1-2 2 15A 240VAC 2 SUNLIGHT RESISTANT PER NEC 1264 ENERGY LANE F1-2 2 30A 240VAC J131 1 SOLADECK 0799-5 WITH 01611 KIT OR EQUIV. 30A 240VAC/60OVDC ARTICLE 300.6 (C)(1)AND ARTICLE I ENPHASE IQ COMBINER 4 W/IQ GATEWAY FOR CONDUCTORS EXPOSED TO WET ST PAUL, MN 55108 SYSTEM SUMMARY I Cl 1 PRODUCTION MONITORING 64A 240VAC 310.10(D). 1 1 (800)620-3370 I JUNCTION BOX BRANCH 1 BRANCH 2 RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2).PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY(DEFINED AS 3 FEET FROM THE POINT OF LOCATIONS SHALL BE SUITABLE FOR L— JB1 NVERTERS PER BRANCH 9 9 � PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY)SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION.CONDUCTORS LOCATED 3 AX AC CURRENT 11.79A 11.79A INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. USE IN WET LOCATIONS PER NEC 2 AXACOUTPUT 2,835W 2,835W ARTICLE 310.10(C). 2 ARRAY STC POWER 7,56OW © ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM,AS PER NEC 690.12(B)(2). AC COMBINER ARRAY PTC POWER 7,245W ©THE DC AND AC CONNECTORS OF THE ENPHASE IQ7X-96-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C).MATING CONNECTORS SHALL COMPLY L——— B1 CB2 Cl AXACCURRENT 24A WITH NEC690.33. GROUNDING NOTES r— 5A 15A AXAC POWER OUTPUT 5,670W 4 THE ENPHASE IQ7X-96-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS(GEC)OR EQUIPMENT GROUNDING CONDUCTORS(EGC).THE 8 Q DERATED AC POWER OUTPUT 5,670W A RATING INCLUDES GROUND FAULT PROTECTION(GFP).TO SUPPORT GFP,USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. ALL EQUIPMENT SHALL BE I PROPERLY GROUNDED PER THE I COMM ©MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS.THEYARE ROHS,OIL 1 REQUIREMENTS OF NEC ARTICLES GATEWAY 3 RESISTANT,AND UV RESISTANT.THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRYNVET AND CERTIFIED TO UL 3003 AND UL 9703. 250&690 RPA ® ALL METAL ENCLOSURES,RACEWAYS,CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B)AND PART III OF PV MODULES SHALL BE GROUNDEDCD CV ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45.THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A)AND NEC 250.169 AND U L M PoC INSTALLED IN COMPLIANCE WITH NEC 250.64. TO MOUNTING RAILS USING MODULE z MAX DC VOLTAGE OFPV MODULE IS EXPECTED TOBE66.6VAT-26°C(-26.1°C-25°C)X-0.141V/C+59AV=66.6V). LUGS OR RACKING INTEGRATED C/) z LJJ LO ( i UTILITY PV DISCONNECT ® AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3)(3). 2 GROUNDING CLAMPS AS ALLOWED > O �� SW1 I AA ± THE ENPHASE IQ COMBINER 4 CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 20A. BY LOCAL JURISDICTION.ALL OTHER \ Q z — i 30A I /'y 200A RINGLESS METER SOCKET WITH LEVER SAFETY BYPASS PER XCEL ENERGY SPECIFICATIONS. EXPOSED METAL PARTS SHALL BE / I L--- ---i 4 GROUNDED USING UL-LISTED LAY-IN Q UTILITY PV DISCONNECT SHALL BE VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY IN ACCORDANCE WITH NEC 690.13(E).THE DISCONNECT SHALL BE LUGS. Q LJJ r uNe ' GENERATION METER LOCATED WITHIN 10 FT OF UTILITY METER AND INSTALLED IN COMPLIANCE WITH NEC 705.20 AND GROUPED AS REQUIRED BY NEC 230.72. ,r(UTILITY-OWNED) INSTALLER SHALL CONFIRM THAT LJ I Z J L— 1 AUTILITY PV DISCONNECT MEETS NEC 690.12(C)REQUIREMENT FORA RAPID SHUTDOWN INITIATION DEVICE 0 KWHR , MOUNTING SYSTEM HAS BEEN ~ O � J I I POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT,INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS,TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING,OR 7 5 ® USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE,IN COMPLIANCE WITH NEC 705.11.THE PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED EVALUATED FOR COMPLIANCE WITH �_ O -- BY NEC 110.3 AND NEC 312.8(A) 3 UL 2703"GROUNDING AND BONDING" LL i F1-2 ir`PV SERVICE DISCONNECT ®ALL AC EQUIPMENT SHALL BE 3-WIRE,SINGLE-PHASE 120/240V. WHEN USED WITH PROPOSED PV CD L---yam 30A 1 EATON DG222NRB r———i N SWA CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS MODULE. 60A i CURRENT-CARRYING MAX. TERM. AMP.@ IF THE EXISTING MAIN SERVICE --- ---� 6 TEMP.CORR. CONT. DERATED TERM. PANEL DOES NOT HAVE A ID TYP CONDUCTOR CONDUIT/CABLE CONDLITORSE. OCPD EGC FACTOR FILL FACTOR CURRENT CURRENT BASE AMP. AMP TEMP. TEMP. LEN. V.D. (150A MSP W/150A MCB) CONDUIT/CABLE. (125%) RATING RATING VERIFIABLE GROUNDING I r ---------1 1 2 10 AWG THHN/THWN-2IN CABLE 2 15A 10 AWG BARE,COPPER 0.76(55°C) 1.0 11.79A 14.74A 30A 23A 90°C 40A 118AFT 1.15% 4 ELECTRODE, IT IS THE I i ENPHASBXABLE,COPPER LOADS 2 2 10AWGTHWN-2,COPPER 0.75"DIA.EMT 4 15A 10 AWG THWN-2,COPPER 0.76(53°C) 0.8 11.79A 14.74A 40A 24.32A 90°C 40A 77.3FT 0.47% CONTRACTOR'S RESPONSIBILITY TO 3 1 1 10 AWG THWN-2,COPPER 0.75"DIA.EMT 2 30A 10 AWG THWN-2,COPPER 0.96(33°C) 1.0 23.58A 29.48A 40A 38AA 75°C 35A 48IN 0.1% INSTALL A SUPPLEMENTAL © 4 1 6 AWG THWN-2,COPPER 0.75"DIA.EMT 2 30A 10 AWG THWN-2,COPPER 0.96(33°C) 1.0 23.58A 29.48A 75A 72A 75°C 65A 48IN 0.04% -Lr 1 GROUNDING ELECTRODE. 1 5 1 1 6 AWG THWN-2,COPPER 0.75"DIA.EMT 2 30A 10 AWG THWN-2,COPPER 0.96(33°C) 1.0 23.58A 29.48A 75A 72A 75°C 65A 48IN 0.04% AC SYSTEM GROUNDING Account: 51-6117954-6 r—�7no ---i 6 1 6 AWG THWN-2,COPPER 1.0"DIA.PUC-80 2 30A N/A 0.96(33°C) 1.0 23.58A 29.48A 75A 72A 75°C 65A 481N 0.04% I I UTILITY METER ELECTRODE CONDUCTOR(GEC) Meter: 94448812 ) KWHR 1120/240V 1�,3W 5 SHALL BE A MINIMUM SIZE#8AWG (EGEC i NE SM 94448812 L___ ___I WHEN INSULATED,#6AWG IF BARE Premise: 303404282 WIRE. Case: 05469040 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED SINGLE-LINE DIAGRAM ACCORDING TO NEC ARTICLE 690.45, 6 AND BE A MINIMUM OF#10AWG PROJECT ID: 90516C-1 WHEN NOT EXPOSED TO DAMAGE, DATE: 5/25/23 AND#6AWG SHALL BE USED WHEN CREATED BY: A.F. EXPOSED TO DAMAGE GROUNDING AND BONDING CHECKED BY. B.W. CONDUCTORS, IF INSULATED,SHALL REVISIONS 7 BE COLOR CODED GREEN,OR MARKED GREEN IF#4AWG OR LARGER � SINGLE-LINE DIAGRAM PV-3 SCALE: NTS PV-3 H U U Lu 'If Wc-> Y aa a a zN U W Z � m Z Z -- _Z Lu m Z O N 0Wasa _ O O Lu- U Q WH O Z a N Q O U m l\\\ c) a J U O �'f > \ \ 1 m } IILW In \ N� Q� Lu = `oI ILL om cn I "j j I = �I r- m = I I h I I z I --------- T la S ZU I I I Y I I 1 to Y I I I I I I I I -----� )III � a-v L-----_ L----J L- • J L-- -J L- --J L-- - I w CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CURRENT-CARRYING MAX. TERM. AMP. TEMP.CORR. CONT. DERATED TERM. ID TYP CONDUCTOR CONDUIT/CABLE CONDUCTORS IN OCPD EGC FACTOR FILL FACTOR CURRENT CURRENT BASE AMP. AMP TEMP. TEMP. LEN. V.D. CONDUIT/CABLE. (125%) RATING RATING 1 2 10AWGTHHN/THWN-2IN CABLE 2 15A 10 AWG BARE,COPPER 0.76(55°C) 1.0 11.79A 14.74A 30A 23A 90°C 40A 118.1FT 1.15% ENPHASHCABLEFOPPER 2 2 10 AWG THWN-2,COPPER 0.75"DIA.EMT 4 15A 10 AWG THWN-2,COPPER 1 0.76(53°C) 0.8 11.79A 14.74A 40A 24.32A 90°C 40A 77.3FT 3 1 10 AWG THWN-2,COPPER 0.75"DIA.EMT 2 30A 10 AWG THWN-2,COPPER 0.96(33°C) 1 1.0 23.58A I 29.48A 40A 38AA 75°C 35A 48IN 1 0.1% 4 1 6 AWG THWN-2,COPPER 0.75"DIA.EMT 2 30A 10 AWG THWN-2,COPPER 0.96(33°C) 1.0 23.58A 29.48A 75A 72A 75°C 65A 48IN 0.04% 5 1 6 AWG THWN-2,COPPER 0.75"DIA.EMT 2 30A 10 AWG THWN-2,COPPER 0.96(33°C) 1.0 23.58A 29.48A 75A 72A 75°C 65A 48IN 0.04% 6 1 6 AWG THWN-2,COPPER 1.0"DIA.PVC-80 2 30A N/A 0.96(33°C) 1.0 23.58A 29.48A 75A 72A 75°C 65A 48IN 1 0.04% AC COMBINER LABELING NOTES 74349 OSEE NOTE NO.4 SW2,MSP) O POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT(MSP,UM)(O 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2020 NEC AND 2018 IFC WILL BE INSTALLED AS REQUIRED. ALL SOLAR PV SYSTEM EQUIPPED ! CAUTION: MULTIPLE SOURCES OF POWER ! LABELS,WARNING(S)AND MARKING SHALL COMPLY ENERGY SW1 -DISCONNECT WITH RAPID SHUTDOWN POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF-MOUNTED SOLAR ARRAYS WITH SAFETY WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, 1 Oi_A.; EATON DG221URB DISCONNECTS AS SHOWN WARNING,AND CAUTION SIGNS USED THE STANDARD TURN RAPID SHUTDOWN HEADER COLORS,HEADER TEXT,AND SAFETY ALERT O O O SWITCH TO THE'OFF' O SYMBOL ON EACH LABEL.THE ANSI STANDARD POSITION TO SHUT DOWN SOLAR ELECTRIC REQUIRES A HEADING THAT IS AT LEAST 50%TALLER PV SYSTEM AND REDUCE PV PANELS N THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 1264 ENERGY LANE 110.21(B). ST PAUL, MN 55108 SW2-DISCONNECT SHOCK HAZARD IN THE EATON DG222NRB ARRAY. A PERMANENT PLAQUE OR DIRECTORY SHALL BE (800)620-3370 O O O O INSTALLED PROVIDING THE LOCATION OF THE SERVICE O 1 4 5 6 7 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME OLOCATION IN ACCORDANCE WITH NEC 690.56(B). NEC 690.56(C)(1) AND IFC 1204.5.1 LABEL(S)WITH MARKING,"TURN RAPID SHUTDOWN SWITCH TO THE'OFF'POSITION TO SHUT DOWN PV UTILITY METER SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," O O AC COMBINER PANEL(Cl) SHALL BE LOCATED WITHIN 3 FT OF SERVICE 2 DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8" ! WARNING ! IN BLACK ON A YELLOW BACKGROUND,AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT CV MAIN SERVICE PANEL THIS EQUIPMENT FED BY MULTIPLE SOURCES. I OF 3/16"IN BLACK ON WHITE BACKGROUND Lli 0 z cy") TOTAL RATING OF ALL OVERCURRENT DEVICES, SERVICE UTILITYPV SOLAR ARRAY LABELS WITH MARKING,"RAPID SHUTDOWN SWITCH U� z LC7 O O O EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE DISCONNECT ( ) O UJ �DISCONNECT FOR SOLAR PV SYSTEM,"SHALL BE LOCATED WITHIN 3 SHALL NOT EXCEED AMPACITY OF BUSBAR. (INSIDE) AC COMBINER 5 FT OF RAPID SHUTDOWN SWITCH THE LABEL SHALL J � z NEC 705.12(B)(3)(3) PV SERVICE DISCONNECT HAVE 3/8"TALL LETTERS AND BE REFLECTIVE WITH > Y Q WHITE TEXT ON A RED BACKGROUND = INSTALLED BY ALL ENERGY SOLAR • 800 620-3370 0 >- NEC 690.56(B) AND NEC 705.10 w Q Uj J z OEACH DISCONNECTING MEANS FOR O PV SYSTEM DISCONNECT(SW1,SW2) O AC DISCONNECT(SW1,SW2) 0 E PHOTOVOLTAIC EQUIPMENT(SW1,SW2) L.L ! WARNING ! CD ELECTRIC SHOCK HAZARD.TERMINALS ON THE PV SYSTEM DISCONNECT MAXIMUM AC OPERATING CURRENT:23.6A LINE AND LOAD SIDES MAY BE ENERGIZED IN THE MAXIMUM AC OPERATING VOLTAGE:240V OPEN POSITION. NEC 690.13(B) NEC 690.13(B) NEC 690.54 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH Account: 51-6117954-6 O SEE NOTE NO.5(SW2) O THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW2,MSP) Meter: 94448812 Premise: 303404282 SHUTDOWNRAPID ! CAUTION ! Case: 05469040 FOR SOLAR PV SYSTEM MULTIPLE SOURCES OF POWER NEC 690.56(C)(3) AND IFC 1204.5.3 NEC 705.10 SAFETY LABELS DOC ID:90516C-1 DATE:5/25/23 CREATOR:A.F. REVIEWER:B.W. REVISIONS PV-4 STRUCTURAL DESIGN PARAMETERS 74349 ELEVATION 869 FT ALL SEISMIC 0.051 SDS ENERGY WIND(ASCE 7-16) 109 MPH,EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 150 PSF ROOF PROPERTIES RIDGE 1 1264 ENERGY LANE ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) y ST PAUL, MN 55108 SLOPE 6/12(26.6°) I I 31111 I I I I 1 0 (800)620-3370 MEAN ROOF HEIGHT 22.5FT I ROOF DECKING 15/32"OSB 1 I I 1 I 1 CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC I MODULE MECHANICAL PROPERTIES I I MODEL REC SOLAR REC420AA PURE-R zr I I I I I I 1 1 I DIMENSIONS(AREA) 68.11N X 44.01N X 1.21N(20.8 SQ FT) I 1 xx O CV WEIGHT 47.4 LBS r`Q I 1 z z MOUNTING SYSTEM PROPERTIES 1 I 1 I 1 1 1 1 I I I �P���` p j L0 RAIL MODEL SNAPNRACK UR-40 I > Y Q SNAPNRACK UR COMPOSITION _ ANCHOR MODEL FLASHED AIR GAP L FOOT(FLASHED),3.751N I Ze I I I I I I I I 1 Q Q O J 2.5 INCH EMBEDMENT INTO TRUSSES FASTENING METHOD WITH(1)5/161N DIA.FASTENER O I � O O � GROUNDING AND INTEGRAL GROUNDING CERTIFIED I I �O � BONDING TO UL 2703 REQUIREMENTS I I 1 I 1 I 1 I I 1 I DEAD LOAD CALCULATIONS LOAD QTY LBS TOTALLBS EAVE MODULES 10 47.4 474.0 MICROINVERTERS 10 2.4 23.8 LINEAR FEET OF RAIL 76 FT 0.4 32.0 ANCHORS 24 2.4 57.0 MISC.HARDWARE 5.8 5.8 TOTAL ARRAY WEIGHT 592.6 LBS AREA NAME QTY SQFT TOTAL SQFT ANCHOR PLACEMENT PARAMETERS ASCE 7-16 MODULES 10 20.8 208.0 � ) DISTANCE a IS EQUAL T010%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION("LHD")OR 40% WIND PRESSURE MODULE WIND MAX.ALLOWABLE MAX.ANCHOR MAX.ALLOWABLE OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LHD OR 3 POINT LOAD(592.6 LBS/24 ATTACHMENTS) 24.7 LBS ZONE EXPOSURE RAIL SPAN SPACING CANTILEVER FT.THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF DIST.LOAD(592.6 LBS/208.0 SQFT) 2.85 PSF ZONES 1,2E,2R NORMAL 48.01N 48.01N 16.31N PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-213-1. ATTACHMENT PLAN NOTES a=MAX(MIN(0.4"MEAN ROOF HEIGHT,0.1"LHD), 0.04"LHD,3 FT) DOC ID:90516C-1 TRUSS LOCATIONS ARE APPROXIMATE.CONTRACTOR DATE:5/25/23 1 MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR 4.8 FT=MAX(MIN(0.4"22.5 FT,0.1 "48.2 FT),0.04"48.2 FT,3 FT) CREATOR:A.F. LOCATIONS.IN NO CASE SHALL THE ANCHOR SPACING REVIEWER:B.W. EXCEED"MAX.ANCHOR SPACING" 1 ATTACHMENT PLAN ORTHOGONAL PROJECTION REVISIONS PV-5.1 SCALE: 1/4" = 1' PV-5. STRUCTURAL DESIGN PARAMETERS 74349 z ELEVATION 869 FT ALL SEISMIC 0.051 SDS ENERGY WIND(ASCE 7-16) 109 MPH,EXPOSURE CATEGORY B, RISK CATEGORY II 341f GROUND SNOW LOAD 50 PSF ROOF PROPERTIES 1264 ENERGY LANE ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) RIDGE Nye y'O ST PAUL, MN 55108 SLOPE 6/12(26.6°) .. _:� j RIDGE (800)620-3370 MEAN ROOF HEIGHT 22AFT I 3r I I I zr I I I I ROOF DECKING 15/32"OSB I I I I I I CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC I I I I 13r I w Y Q I I I 1 I MODULE MECHANICAL PROPERTIES I I I I MODEL REC SOLAR REC420AA PURE-R 48`, DIMENSIONS(AREA) 68.11N X 44.01N X 1.21N(20.8 SQ FT) I I 1 I I RIDGE W W cN WEIGHT 47.4 LBS Y I I I I I I I I I— z Z I Zn I I I I I I I 1 I I Ol I I I 2n I I Cl) LJJ LC7 MOUNTING SYSTEM PROPERTIES O RAIL MODEL SNAPNRACK UR-40 A I I I I I I j Y SNAPNRACK UR COMPOSITION I w _ ANCHOR MODEL FLASHED L-FOOT(FLASHED),3.751N I I AIR GAP W FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES I I 1 1 I 1 1 I I I I I I 1 LJJ z O i WITH(1)5/161N DIA.FASTENER 3e 2e Q3e ~ O 0 CE GROUNDING AND INTEGRAL GROUNDING CERTIFIED I I I I I I Q OLj_ BONDING TO UL 2703 REQUIREMENTS I I I I 1 I I 1 I 1 I 1 DEAD LOAD CALCULATIONS EAVE LOAD QTY LBS TOTALLBS MODULES 8 47.4 379.2 MICROINVERTERS 8 2.4 19.0 LINEAR FEET OF RAIL 60 FT 0.4 25.4 ANCHORS 20 2.4 47.5 MISC.HARDWARE 4.9 4.9 TOTAL ARRAY WEIGHT 476.0 LBS AREA NAME QTY SQFT TOTAL SQFT ANCHOR PLACEMENT PARAMETERS ASCE 7-16 MODULES 8 20.8 166.4 � ) DISTANCE a IS EQUAL T010%OF THE BUILDING'S LEAST HORIZONTAL DIMENSION("LHD")OR 40% WIND PRESSURE MODULE WIND MAX.ALLOWABLE MAX.ANCHOR MAX.ALLOWABLE OF THE MEAN ROOF HEIGHT,WHICHEVER IS SMALLER,BUT NOT LESS THAN 4%OF THE LHD OR 3 POINT LOAD(476.0 LBS/20 ATTACHMENTS) 23.8 LBS ZONE EXPOSURE RAIL SPAN SPACING CANTILEVER FT.THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF DIST.LOAD(476.0 LBS/166.4 SQFT) 2.86 PSF ZONES 1,2E,2N, NORMAL 48.01N 48.01N 16.31N PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-213-1. ATTACHMENT PLAN 2R,3E,3R NOTES a=MAX(MIN(0.4"MEAN ROOF HEIGHT,0.1"LHD), 0.04"LHD,3 FT) DOC ID:90516C-1 TRUSS LOCATIONS ARE APPROXIMATE.CONTRACTOR DATE:5/25/23 1 MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR 4.8 FT=MAX(MIN(0.4"22.4 FT,0.1 "48.2 FT),0.04"48.2 FT,3 FT) CREATOR:A.F. LOCATIONS.IN NO CASE SHALL THE ANCHOR SPACING REVIEWER:B.W. EXCEED"MAX.ANCHOR SPACING" 1 ATTACHMENT PLAN ORTHOGONAL PROJECTION REVISIONS PV-5.2 SCALE: 1/4" = 1' PV-5. 2 S REC 420 BOB REC420AA PURE-R 11 .8" 7.9" Drive Link 1 L= 68. 10" 11.41" 20.4" l W= 44" D= 1 .20" Weight= 47.4 Ibs L Short Side Mounting - Yes 74349 MOUNTING SYSTEM NOTES FLASHING SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURERS'INSTRUCTIONS. I ALL IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED HERE AND INSTRUCTIONS ENERGY 2 PROVIDED BY A MANUFACTURER,THE MANUFACTURER'S INSTRUCTIONS SHALL CLAMPING ZONE SUPERCEDE. 1264 ENERGY LANE ST PAUL, MN 55108 (800)620-3370 --� SNAPNRACK PV MODULE C BONDING MID CLAMP ULTRA FOOT FOR U FLASHING ROOF FRAMING PV-6 PV MODULE SNAPNRACK \ � COMP FLASHING ' = W W CV (D Cy") B SNAPNRACK- CJ) Z Lo UR-40 RAIL I SLIDE FLASHING >- 0 W u PV-6 SNAPNRACK ULTRA �� UNDER THE 3RD Q z RAIL MOUNTING COURSE OF Y = HARDWARE SHINGLES COMP.SHINGLE ROOFING 0 J >- ROOF FRAMING Q O LLI ROOF UNDERLAYMENT � /'� LLJ J ROOF DECKING -- _i' SNAPNRACK UMBRELLA LAG Q O EMBEDDED INTO ROOF FRAMING O LL A RACKING ELEVATION TRANSVERSE VIEW ATTACHMENT DETAIL TRANSVERSE VIEW CD PV-6 SCALE: NTS PV-6 SCALE: NTS D PV MODULE PV-6 SNAPNRACK ' 1 I END CLAMP ASSEMBLY SNAPNRACK BONDING PV MODULE UR-40 RAIL (ADJUSTABLE END / ---� ULTRA FOOT MID CLAMP CLAMP SHOWN) CUT COMP.SHINGLE AS ; `, FOR U FLASHING SNAPNRACK UR-40I REQ'D TO CLEAR ULTRA SNAPNRACK RAIL END CAP �� FOOT - COMP FLASHING COMP.SHINGLE p ROOFING COMP.SHINGLE ROOFING ROOF UNDERLAYMENT SLIDE FLASHING UNDER SNAPNRACK ROOF DECKING THE 3RD COURSE OF ATTACHMENT DETAILS UR-40 RAIL ROOF DECKING `��_ - -� SHINGLES SNAPNRACK UMBRELLA LAG ROOF FRAMING DOC ID:90516C 1 ROOF FRAMING SPACING ATTACHMENT SPAN _ ROOF FRAMING EMBEDDED INTO ROOF FRAMING DATE:5/25/23 CREATOR:A.F. REVIEWER:B.W. B RACKING ELEVATION LONGITUDINAL VIEW D ATTACHMENT DETAIL LONGITUDINAL VIEW REVISIONS PV-6 SCALE: NTS PV-6 SCALE: NTS PV-6 ON GENERAL NOTES 74349 AT LEAST TWO 3'-WIDE PATHWAYS ON SEPARATE ROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE,SHALL ALL BE PROVIDED LDINGS,WITH AT LEAST ONE PATHWAY ON TOE STREEN ALL T OR DRIVEWAY SIDE OF HE ENERGY 1 ROOF.FOR EACH ROOF PLANE WITH A PV ARRAY,AT LEAST ONE SUCH PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE,OR ON AN ADJACENT ROOF PLANE,OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. (IFC 1204.2.1.1) 1264 ENERGY LANE FOR PV ARRAYS OCCUPYING 33%OR LESS OF THE PLAN ST PAUL, MN 55108 2 VIEW TOTAL ROOF AREA,A MIN.18"-WIDE SETBACK IS (800)620-3370 REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. (IFC 1204.2.1.2) PV MODULES SHALL NOT BE PLACED BELOW AN 3 EMERGENCY ESCAPE/RESCUE OPENING.A 3'-WIDE PATHWAY SHALL BE PROVIDED TO SUCH AN OPENING. (IFC 1204.2.2) 4 ROOF FACES WITH NO PV ARE DESIGNATED FOR FIRE VENTILATION AND ACCESS 1 1.5'WIDE SMOKE-VENTILATION SETBACK,PER IFC w z 1204.2.1.2 CV O Cy") CJ) z LLo O 3.0'WIDE FIRE ACCESS PATHWAY,PER IFC 1204.2.1.1 >_ 0 � Lc-) 3O ROOF ACCESS POINT Y Q 2 1 PV MODULES INSTALLED ON ROOF WITH SNAPNRACK ULTRA RAIL MOUNTING SYSTEM.THE MOUNTING 0 J W 2 O SYSTEM IS UL 2703 CLASS A FIRE RATED ON THIS W Q Co 4 WHEN INSTALLED WITH TYPE 1 C) OR 2 MODULES ROOF HE REC SOLAR REC4 0AA PURE-R IS O 3 UL 61730-1 CERTIFIED TYPE 2. Q0 p 5 BUILDING IS 2-STORY,GROUP R3 Q� Irl- L.L TOTAL PLAN VIEW ARRAY AREA IS 335.2 SQ.FT,WHICH 0 6 REPRESENTS 14.5%OF TOTAL PLAN VIEW ROOF AREA (2311.7 SQ.FT) 1 THIS SYSTEM UTILIZES MICROINVERTERS.THERE ARE 7 NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. 1 ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE $ INTERIOR OF THE BUILDING,AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS.NO 4 CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. 2 1 4 3 FIRE SAFETY PLAN 3 DOC ID:90516C-1 2 DATE:5/25/23 _ CREATOR:A.F. l41$p data @2023 REVIEWER:B.W. 1 FIRE SAFETY PLAN REVISIONS J SCALE: 1" = 10' PV-7 Conductor, Conduit, and OCPD Sizing Validation 2.Wire, Conduit, and OCPD Code Compliance Validation 1. Maximum System DC Voltage Test 2.1.#1: Branch cables: Microinverter to Transition Box 1.1. Enphase microinverter system w118 REC Solar REC420AA Pure-R(420W)s Circuit Section Properties G. Minimum Required EGC Size 14 AWG see NEC Table 250122 Conductor 12 AWG THHN/THWN-2 in Enphase Array Properties NEC Code Validation Tests Q Cable Copper The smallest EGC size allowed is 14 AWG for OCPD rating 15A Array Type Microinuerfer Array Equipment Ground Conductor EGC 6 AWG Bare Copper according to Table 250.122. PV Source Circuit maximum Voc must not exceed PASS OCPD s 15A System Description Enphase microinuerter system w/18 600V NEC Code Validation Tests REC Solar REC420AA Pure-R Raceway/Cable Cable 420W s 66.59V<600V=true Lowest Terminal Temperature 90°C o Module REC420AA Pure-R 420W RatingOCPD rating must be at least 125/o of Continuous PASS Highest number of modules in series 1 Maximum Wire Temperature 55°C Current(NEC 240.4) in a PV Source Circuit Power Source Description Branch of 9 IQ7X-96-2-US 15A-11.79A X 1.25=true Design Low Temp. -26.1°C microinuerters Module voc 59.4V Power Source Current 11.79A Derated ampacity must exceed OCPD rating,or PASS Temp.Coefficient voc -0.141V/C Volta e 240V rating of next smaller OCPD(NEC 240.4) 23A-15A(OCPD Rating)=true NEC Code Calculations NEC Code Calculations OCPD rating must not exceed max OCPD rating PASS for conductor(NEC 240.4) A. Maximum Voltage of PV Source Circuit 66.59V A. Continuous Current 11.79A 15(OCPD Rating)-20A =true see NEC 6907(A) see NEC Article 100 Equipment maximum rated output current is 9 X 1.31A=11.79A Derated Ampacity must be greater than or equal to PASS NEC 690.7(A)requires that if the PV module manufacturer provides a p the Continuous Current(NEC Article 100) temperature coefficient of open-circuit voltage,it must be used to 23A>-11.79A=true calculate the PV array's maximum system voltage.It includes an B. Ampacity of Conductor 30A information note recommending the use of the ASHRAE'Extreme Annual see NEC Table 31016 Conductor Ampacity must be at least 125%of PASS Mean Minimum Design Dry Bulb Temperature'as the design low Conti Current 215.2(A)(1)) temperature.Using these values,the module Voc(59.4V)will increase to Ampacity for a copper conductor with 90°C insulation in Continuous urren (NEC( 66.59V at the design low temperature(-26.1°C). conduit/cabblele is s 30A. 30A>11.79A x 1.25=true (-26.1°C-25°C)X-0.141V/C+59AV=66.59V C. Derated Ampacity of Conductor 23A Max current for terminal must be at least 125%of PASS The module Voc at the design low temperature is 66.59V. see NEC 31015(B)(2),NEC Table 31015(C)(1),and NEC Article 100 the Continuous Current.(NEC 110.14(C)) 66.59V X 1=66.59V 30A-11.79A X 1.25 =true The temperature factor for 90°C insulation at 55°C is 0.76. The fill factor for a conduit/cable that has 2 wires is 1. EGC must meet code requirements for minimum PASS The ampacity derated for Conditions of Use is the product of the size(NEC Table 250.122) conductor ampacity(30A)multiplied by the temperature factor(0.76)and 6 AWG>=14 AWG=true by the fill factor(1). 30A X 0.76 X 1 =22.8A rounded to 23A D. Max Current for Terminal Temp. Rating 30A see NEC 11014(C) The lowest temperature rating for this conductor at any termination is 90°C. Using the method specified in NEC 110.14(C),the maximum current permitted to ensure that the device terminal temperature does not exceed its 90°C rating would be the amount referenced in the 90°C column in NEC Table 310.16,which is 30A. E. Minimum Allowed OCPD Rating 15A see NEC 2404 NEC 690.9(B)(1)requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 11.79A X 1.25=14.74A F. Maximum Allowed OCPD Rating 20A see NEC 2404(D) NEC 240.4(D)requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. 2.2.#2:AC Branch Output:Transition Box to AC Combiner 2.3.#3:AC Combiner Output:AC Combiner to AC Disconnect Circuit section Properties G. Minimum Required EGC Size 14 AWG Circuit section Properties G. Minimum Required EGC Size 10 AWG see NEC Table 250122 and NEC 69045 see NEC Table 250122 Conductor 10 AWG THWN-2 Copper Conductor 10 AWG THWN-2 Copper Equipment Ground Conductor(EG21 10 AWG THWN-2 Copper The smallest EGC size allowed is 14 AWG for OCPD rating 15A Equipment Ground Conductor EGC 10 AWG THWN-2 Copper The smallest EGC size allowed is 10 AWG for OCPD rating 30A OCPD s 15A according to Table 250.122. OCPD s 30A according to Table 250.122. According to NEC 690.45,it is not necessary to increase the size of the Raceway/Cable/Cable 0.75"dia.EMT Raceway/Cable 0.75"dia.EMT PV array's EGC when conductors are oversized for voltage drop H. Minimum Recommended Conduit Size 0.5 dia. Lowest Terminal Temperature 90°C considerations. Lowest Terminal Temperature 75°C RatingRating see NEC 30017 Maximum Wire Temperature 53°C Maximum Wire Temperature 33°C The total area of all conductors is 0.0633in2 With a maximum fill rate of Power Source Description Branch of 9 IQ7X-96-2-US H. Minimum Recommended Conduit Size 0.75 dla. Power Source Description Enphase microinverter system w/18 0.4,the recommended conduit diameter is 0.5. microinverters see NEC 30017 REC Solar REC420AA Pure-R Power Source Current 11.79A The total area of all conductors is 0.1266in2 With a maximum fill rate of 420W s 2L Descri tion Size Type Area Total Area Voltage 240V 0.4,the recommended conduit diameter is 0.75. Power Source Current 123.58A 2 Conductor 10 AWG THWN-2 0.0211in2 0.0422in2 Volta e 240V NEC Code Calculations Qt Description Size Type Area Total Area 1 Equipment Ground 10 AWG THWN-2 0.0211in2 0.0211in2 4 Conductor 10 AWG_THWN-2 0.0211in2 0.0844in2 NEC Code Calculations 3 0.0633in2 A. Continuous Current 11.79A 2 Equipment Ground 10 AWG THWN-2 0.0211in2 0.0422in' 0.0633in2/0.4=0.1583in2(Corresponding to a diameter of 0.5") see NEC A�tic%100 A. Continuous Current 23.58A 6 0.1266in2 see NECA#/c%100 Equipment maximum rated output current is 9 X 1.31A=11.79A z z NEC Code Validation Tests 0.1266in /0.4=0.3165in (Corresponding to a diameter of 0.75") Equipment maximum rated output current is 23.58A D rating must be at least 125%of Continuous PASS B. Ampacity of Conductor 40A NEC Code Validation Tests Current(NEC 240.4) see NEC Table 31016 B. Ampacity of Conductor 40A o see NEC Table 31016 30A>=23.58A X 1.25=true Ampacity(30°C)for a copper conductor with 90°C insulation in OCPD rating must be at least 125/o of Continuous PASS conduit/cable is 40A. Current(NEC 240.4) Ampacity(30°C)for a copper conductor with 90°C insulation in Derated ampacity must exceed OCPD rating,or PASS 15A-11.79A X 1.25=true conduit/cable is 40A. rating of next smaller OCPD(NEC 240.4) C. Derated Ampacity of Conductor 24.32A 38.4A-30A(OCPD Rating)=true Derated ampacity must exceed OCPD rating,or PASS see NEC 310 15(B)(2),NEC Table 31015(C)(1),and NECArtic%100 C. Derated Ampacity of Conductor 38.4A rating of next smaller OCPD(NEC 240.4) OCPD rating must not exceed max OCPD rating PASS see NEC 310,15(B)(2),NEC Table 310.15(C)(1),and NECA#ic%100 for conductor240.4 The temperature factor for 90°C insulation at 53°C is 0.76. 24.32A>=15A(OCPD Rating)=true (NEC( ) The fill factor for a conduit/cable that has 4 wires is 0.8. The temperature factor for 90°C insulation at 33°C is 0.96. 30(OCPD Rating)-30A =true The ampacity derated for Conditions of Use is the product of the OCPD rating must not exceed max OCPD rating PASS The fill factor for a conduit/cable that has 2 wires is 1. conductor ampacity(40A)multiplied by the temperature factor(0.76)and for conductor(NEC 240.4) The ampacity derated for Conditions of Use is the product of the Derated Ampacity must be greater than or equal to PASS by the fill factor(0.8). 15(OCPD Rating)<-30A =true conductor ampacity(40A)multiplied by the temperature factor(0.96)and the Continuous Current(NEC Article 100) 40A X 0.76 X 0.8=24.32A by the fill factor(1). 38.4A-23.58A=true Derated Ampacity must be greater than or equal to PASS 40A X 0.96 X 1 =38.4A D. Max Current for Terminal Temp. Rating 40A the Continuous Current(NEC Article 100) Conductor Ampacity must be at least 125%of PASS p g 24.32A>=11.79A=true Continuous Current(NEC 215.2(A)(1)) see NEC 11014(C) - - D. Max Current for Terminal Temp. Rating 35A 40A>23.58A x 1.25=true Conductor Ampacity must be at least 125%of PASS see NEC 1/014(C) The lowest temperature rating for this conductor at any termination is P ty 901C Continuous Current(NEC 215.2(A)(1)) The lowest temperature rating for this conductor at any termination is Max current for terminal must be at least 125%of PASS Using the method specified in NEC 110.14(C),the maximum current 40A>11.79A x 1.25=true 75°C. the Continuous Current.(NEC 110.14(C)) permitted to ensure that the device terminal temperature does not exceed Using the method specified in NEC 110.14(C),the maximum current 35A-23.58A X 1.25 =true Max current for terminal must be at least 125%of PASS permitted to ensure that the device terminal temperature does not exceed its NECTable rating would hi the amount referenced in the 90°C column in p EGC must meet code requirements for minimum PASS C Table 310.16,which is 40A. the Continuous Current.(NEC 110.14(C)) its 75°C rating would be the amount referenced in the 75°C column in q 40A-11.79A X 1.25 =true NEC Table 310.16,which is 35A. size(NEC Table 250.122) E. Minimum Allowed OCPD Rating 15A 10 AWG-10 AWG=true EGC must meet code requirements for minimum PASS see NEC 2404 E. Minimum Allowed OCPD Rating29A size(NEC Table 250.122) see NEC 2404 ; Conduit must meet code recommendation for PASS NEC 690.9(B)(1)requires OCPD be rated for no less than 1.25 times 10 AWG-14 AWG=true minimum size(NEC 300.17) Continuous Current of the circuit. NEC 690.9(B)(1)requires OCPD be rated for no less than 1.25 times 0.75in.-0.5in.=true 11.79A X 1.25=14.74A Conduit must meet code recommendation for PASS Continuous Current of the circuit. minimum size(NEC 300.17) 23.58A X 1.25=29.48A rounded down to 29A F. Maximum Allowed OCPD Rating 30A 0.75in.-0.75in.=true see NEC 2404(D) F. Maximum Allowed OCPD Rating 30A NEC 240.4(D)requires that OCPD rating not exceed 30A when see NEC 2404(D) protecting a Copper 10 AWG conductor. NEC 240.4(D)requires that OCPD rating not exceed 30A when protecting a Copper 10 AWG conductor. 2.4.#4:AC Disconnect Output:AC Disconnect to PV Generation Meter 2.5.#5: Production Meter Output: PV Generation Meter to Utility Disconnect Circuit section Properties F. Minimum Required EGC Size 10 AWG Circuit section Properties F. Minimum Required EGC Size 10 AWG Conductor 6 AWG THWN-2 Copper see NEC Table 250122 and Conductor 6 AWG THWN-2 NEC 69045 Copper see NEC Table 250122 and NEC 690 45 Equipment Ground Conductor(EG21 10 AWG THWN-2 Copper The smallest EGC size allowed is 10 AWG for OCPD rating 30A Equipment Ground Conductor EGC 10 AWG THWN-2 Copper The smallest EGC size allowed is 10 AWG for OCPD rating 30A OCPD s 30A according to Table 250.122. OCPD s 30A according to Table 250.122. Raceway/Cable 0.75"dia.EMT According to NEC 690.45,it is not necessary to increase the size of the Raceway/Cable 0.75"dia.EMT According to NEC 690.45,it is not necessary to increase the size of the PV array's EGC when conductors are oversized for voltage drop PV array's EGC when conductors are oversized for voltage drop Lowest Terminal Temperature 75°C considerations. Lowest Terminal Temperature 75°C considerations. RatingRating Maximum Wire Temperature 33°C Maximum Wire Temperature 33°C G. Minimum Recommended Conduit Size 0.75 dia. G. Minimum Recommended Conduit Size 0.75„ dia. Power Source Description Enphase microinverter system w/18 see NEC0017 Power Source Description Enphase microinverter system w/18 see NEC300,17 REC Solar REC420AA Pure-R REC Solar REC420AA Pure-R 420W s The total area of all conductors is 0.1225in'.With a maximum fill rate of 420W s The total area of all conductors is 0.1591 inZ.With a maximum fill rate of Power Source Current 23.58A 0.4,the recommended conduit diameter is 0.75. Power Source Current 23.58A 0.4,the recommended conduit diameter is 0.75. Volta e 1240V Ivoitage 1240V LtL Description Size Type Area Total Area 2L Description Size Type Area Total Area NEC Code Calculations 2 Conductor 6 AWG THWN-2 0.0507in' 0.1014in' NEC Code Calculations 2 Conductor 6 AWG THWN-2 0.0507in' 0.1014in' A. Continuous Current 23.58A 1 Equipment Ground 10AWG THWN-2 0.0211in' 0.0211in' A. Continuous Current 23.58A 1 Neutral 8AWG THWN-2 0.0366in' 0.0366in' see NECA#Icle 100 3 0.1225in' see NECA#Icle 100 1 Equipment Ground 10AWG THWN-2 0.0211in' 0.0211in' Equipment maximum rated output current is 23.58A 0.1225in2/0.4=0.3063in2(Corresponding to a diameter of 0.75") Equipment maximum rated output current is 23.58A 4 0.1591in' NEC Code Validation Tests B. Ampacity of Conductor 75A B. Ampacity of Conductor 75A 0.1591 inZ/0.4=0.3978in2(Corresponding to a diameter of 0.75") see NEC Table 31016 OCPD rating must be at least 125%of Continuous PASS see NEC Table 31016 NEC Code Validation Tests Ampacity(30°C)for a copper conductor with 900C insulation in Current(NEC 240.4) Ampacity(30°C)for a copper conductor with 900C insulation in OCPD rating must be at least 125%of Continuous PASS conduit/cable is 75A. 30A-23.58A X 1.25=true conduit/cable is 75A. Current(NEC 240.4) t72A ated ampacity must exceed OCPD rating,or PASS 30A-23.58A X 1.25=true C. Derated Ampacity of Conductor 72A C. Derated Ampacity of Conductor 72A see NEC 31015(B)(2),NEC Table 31015(C)(1J,and NECA#ic%100 I g of next smaller OCPD(NEC 240.4) see NEC 31015(B)(2),NEC Table 31015(C)(1J,andNECA#ic%100 Derated ampacity must exceed OCPD rating,or PASS >=30A(OCPD Rating)=true rating of next smaller OCPD(NEC 240.4) The temperature factor for 90°C insulation at 33°C is 0.96. The temperature factor for 900C insulation at 330C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. Derated Ampacity must be greater than or equal to PASS The fill factor for a conduit/cable that has 2 wires is 1. 72A>=30A(OCPD Rating)=true The ampacity derated for Conditions of Use is the product of the the Continuous Current(NEC Article 100) The ampacity derated for Conditions of Use is the product of the Derated Ampacity must be greater than or equal to PASS conductor ampacity(75A)multiplied by the temperature factor(0.96)and 72A-23.58A=true conductor ampacity(75A)multiplied by the temperature factor(0.96)and the Continuous Current(NEC Article 100) by the fill factor(1). by the fill factor(1). 75A X 0.96 X 1=72.OA Conductor Ampacity must be at least 125%of PASS 75A X 0.96 X 1 =72.OA 72A-23.58A=true Continuous Current(NEC 215.2(A)(1)) Conductor Ampacity must be at least 125%of PASS D. Max Current for Terminal Temp. Rating 65A 75A>23.58Ax 1.25=true D. Max Current for Terminal Temp. Rating 65A Continuous Current(NEC 215.2(A)(1)) see NEC 11014(C) Max current for terminal must be at least 125%of PASS see NEC 1/014(C) 75A>23.58A x 1.25=true The lowest temperature rating for this conductor at any termination is the Continuous Current.(NEC 110.14(C)) The lowest temperature rating for this conductor at any termination is Max current for terminal must be at least 125%of PASS 75°C. 65A-23.58A X 1.25 =true 75°C. the Continuous Current.(NEC 110.14(C)) Using the method specified in NEC 110.14(C),the maximum current Using the method specified in NEC 110.14(C),the maximum current 65A>-23.58AX 1.25 =true permitted to ensure that the device terminal temperature does not exceed EGC must meet code requirements for minimum PASS permitted to ensure that the device terminal temperature does not exceed its 750C rating would be the amount referenced in the 750C column in size(NEC Table 250.122) its 750C rating would be the amount referenced in the 750C column in EGC must meet code requirements for minimum PASS NEC Table 310.16,which is 65A. 10 AWG-10 AWG=true NEC Table 310.16,which is 65A. size(NEC Table 250.122) Conduit must meet code recommendation for PASS 10 AWG-10 AWG=true E. Minimum Allowed OCPD Rating 29A E. Minimum Allowed OCPD Rating 29A see NEC 2404 minimum size(NEC 300.17) see NEC 2404 Conduit must meet code recommendation for PASS NEC 690.9(B)(1)requires OCPD be rated for no less than 1.25 times 0.75in.-0.75in.=true NEC 690.9(B)(1)requires OCPD be rated for no less than 1.25 times minimum size(NEC 300.17) Continuous Current of the circuit. Continuous Current of the circuit. 0.75in.-0.75in.=true 23.58A X 1.25=29.48A rounded down to 29A 23.58A X 1.25=29.48A rounded down to 29A 2.6.#6: Utility Disconnect Output: Utility Disconnect to Main Service Panel Circuit section Properties F. Minimum Recommended Conduit Size 0.75" dia. Conductor 6 AWG THWN-2 Copper see NEC 30017 Equipment Ground Conductor EGC N/A The total area of all conductors is 0.138inz.With a maximum fill rate of OCPD s 30A 0.4,the recommended conduit diameter is 0.75. Raceway/Cable 1.0"dia.PVC-80 jt Description Size Type Area Total Area Lowest Terminal Temperature 75°C 2 Conductor 6 AWG THWN-2 0.0507in' 0.1014in' Rating Maximum Wire Temperature 33°C 1 Neutral 8 AWG THWN-2 0.0366in' 0.0366in' Power Source Description Enphase microinverter system w/18 3 0.138in' REC Solar REC420AA Pure-R 420W s 0.138in2/0.4=0.345in2(Corresponding to a diameter of 0.75") Power Source Current 23.58A Volta e 1240V NEC Code Validation Tests NEC Code Calculations OCPD rating must be at least 125%of Continuous PASS Current(NEC 240.4) A. Continuous Current 23.58A 30A-23.58A X 1.25=true see NECA#lcle 100 Derated ampacity must exceed OCPD rating,or PASS Equipment maximum rated output current is 23.58A rating of next smaller OCPD(NEC 240.4) B. 72A>=30A(OCPD Rating)=true see Ampacitye NEC Table 3 1016 of Conductor 75A Derated Ampacity must be greater than or equal to PASS s the Continuous Current(NEC Article 100) Ampacity(30°C)for a copper conductor with 900C insulation in 72A>-23.58A=true conduit/cable is 75A. Conductor Ampacity must be at least 125%of PASS C. Derated Ampacity of Conductor 72A Continuous Current(NEC 215.2(A)(1)) see NEC 31015(B)(2),NEC Table 31015(C)(1),and NECA#ic%100 75A>23.58A x 1.25=true The temperature factor for 900C insulation at 330C is 0.96. Max current for terminal must be at least 125%of PASS The fill factor for a conduit/cable that has 2 wires is 1. the Continuous Current.(NEC 110.14(C)) The ampacity derated for Conditions of Use is the product of the 65A>-23.58A X 1.25 =true conductor ampacity(75A)multiplied by the temperature factor(0.96)and by the fill factor(1). Conduit must meet code recommendation for PASS 75A X 0.96 X 1=72.OA minimum size(NEC 300.17) 1.0in.>=0.75in.=true D. Max Current for Terminal Temp. Rating 65A see NEC 11014(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in NEC 110.14(C),the maximum current permitted to ensure that the device terminal temperature does not exceed its 750C rating would be the amount referenced in the 750C column in NEC Table 310.16,which is 65A. E. Minimum Allowed OCPD Rating 29A see NEC 2404 NEC 690.9(B)(1)requires OCPD be rated for no less than 1.25 times Continuous Current of the circuit. 23.58A X 1.25=29.48A rounded down to 29A REC SOLAR'S MOST TRUSTEDREC PROOLJET 5PEEIREATION5 , .. GENERAL DATA ,130±2.5[68.,!0.,] P � , Y �, • _ 880[34.6] _ 425 n611 Cell type: 80half-cut REC bifacial,heterojunction cells with -.,. lead-free,gaplesstechnology T ■ ■ T ALPHA accordance REC Glass 013in(3.2mm)solarglasswithantirefnccorda cewit EN121 0 in accordan ce with EN 12150 co=4.om� Backsheet: Highly resistant polymer(black) 1700[671 11-.7] Frame: Anodized aluminum(black) _ PURER SERIES ry Junction box: 4-part,4 bypass diodes,lead-free IP68rated,in accordancewith IEC 62790 R Connectors: StaubliMC4PV KBT4/KST4(4mm2) _A' • in accordancewith IEC 62852,IP68onlywhen connected ioa­.ou PRODUCT SPECIFICATIONS 12AWG(4mmz)PVwire,67+67in(1.7+1.7m) zo5V5 Cable:VMS in accordancewith EN 50618 ioa�.oz� Lorem iP-m17 Dimensions: 68.1x44.0x1.2in(20.77ft2)/1730x1118x30mm(1.93m2) _ �' s94i3R3.4*o.,2] 22.5[o.9] Weight: 47.4lbs(21.5 kg) 1 \ Vk Origin: Made in Singapore ir, Measurements in inches[mm[ ■ ELECTRICAL DATA Product Code`:RECxxxAA PURE-R CERTIFICATIONS Power Output-PMAJWp) 400 410 420 430 IEC61215:2016,IEC61730:2016,UL61730 .• ti IEC 62804 PID Watt Class Sorting-(W) 0/+10 0/+10 0/+10 0/+10 ( IEC61701 Salt Mist w+ ;� Nominal Power Voltage VMPPIV) 48.8 49.4 50.0 50.5 IEC62716 Ammonia Resistance 4 Nominal Power Current-IMPP(A) 8.20 8.30 8.40 8.52 U1_61730 Fire Type Class 2 to Open Circuit Voltage-Voc(V) 58.9 59.2 59.4 59.7 IEC62782 Dynamic Mechanical Load IEC61215-2:2016 Hailstone(35mm) o Short Circuit Current-Isc(A) 8.73 8.81 8.89 8.97 IEC62321 Lead-freeacc.toRoHSEU863/2015 Power Density(W/ft2) 19.26 19.74 20.22 20.7 ISO14001,ISO 9001,IEC 45001,IEC 62941 ,.� Panel Efficiency(%) 20.7 21.2 21.8 22.3 lC^II�J C (♦� " Power Output PMAx(Wp) ttv 305 312 320 327 nce cek r.d-Free ` r NominalPowerVoltage-VMPP(V) 46.0 46.6 47.1 47.6 TEMPERATURE RATINGS' O Nominal Power Current- (A) 6.64 6.70 6.78 6.88 2 MPP Nominal Module Operating Temperature: 44°C(±2°C) Z Open e-V (V) 55.5 55.8 56.0 56.3 0 P g oc Temperature coefficient of -0.26/o/°C Short CircuitCurrent-I5c(A) 7.05 7.12 7.18 7.24 Temperature coefficient ofVoc: -0.24%/°C -. PANEL Values at standard test conditions(STC:airmassAM15,irradiance10.75W/sgft(1000W/m'1temperature77°F(25°C),basedonaproductionspread Temperature coefficient oflsc: 0.04%/°C with a tolerance of Pam,V"&Ix±3%within onewatt class.Nominal module operatingtemperature(NMOT:air mass AM 1.5,irradiance800 W/m', temperature 68°F(20°C),windspeed 3.3 ft/s(1 m/s).'Where xxu indicatesthe nominal power class(P )at STC above. *The temperature coefficients stated are linear values j MAXIMUM RATINGS WARRANTY DELIVERY INFORMATION _ MODULE EURRENTOperationaItemperature: -40...+85°C Standard REC ProTrust Panels per pallet: 33 - [ C P. S stemvolta e: 1000V Installed byanREC Panels er40ftGPhi GP/high 858(26 allets) lo Y g No Yes Yes P / g P Certified Solar Professional s Test load(front): +7000Pa(1461bs/ft2)` System Size All s25kW 25-500kW Panels per 53 ft truck: 858(26 pallets) 5R OIL ITest load(rear): -4000 Pa(83.5Ibs/ft2)` Product Warranty(yrs) 20 25 25 410111111 LOW LIGHT BEHAVIOUR Series fuse rating: 25 A Power Warranty(yrs) 25 25 25 • Labor Warrant (yrs) 0 25 10 Typical low irradiance performance of module atSTC: ,�• Reverse current: 25 A Y(Y ) See installation manualfor mounting instructions. Power in Year 1 98% 98% 98% .t Design load Test load/1.5(safetyfactor) o 0 o S m Annual Degradation 0.25% 0.25% 0.25/0 x-- :---- - - --J i i Power in Year 25 92% 92% 92% ------------------ ------------------ w See warranty documents for details.Conditions apply °1 -------------------------- •,,, �430 wP . n Availablefrom: 25_R�Ru YEA m r. •20.7 v-/F/T WARRANTY (X EFFIDENE Founded inl996,REC Group scomternational pioneering solar energy company dedicated to empowering consumers with clean,affordable solar power.As -❑ 5 R Solar's Most Trusted,REC 22.3% y is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar panels it manufactures. ■ . a Headquartered in Norway with operational headquarters in Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. www.recgroup.com Data Sheet Enphase IQ 7X Microinverter Enphase Microinverters Region:AMERICAS INPUT DATA(DC) IQ7X-96-2-US and IQ7X-96-B-US Commonly used module pairings' 320 W-460 W+ Module compatibility 96-cell PV modules Maximum input DC voltage 79.5 V Peak power tracking voltage 53 V-64 V Operating range 25 V-79.5 V Min/Max start voltage 33 V/79.5 V The high-powered smart grid-ready Max DC short circuit current(module Isc) 10 A Enphase Enphase IQ 7X Micro- dramatically simplifies the Overvoltage class DC port II installation process while achieving the highest DC port backfeed current 0 A Q 7X M i c ro i nve rte r PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; system efficiency for systems with 96-cell modules. AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @ 240 VAC @ 208 VAC Part of the Enphase IQ System,the IQ 7X Micro Peak output power 320 VA integrates with the Enphase IQ Envoy- Enphase IQ Maximum continuous output power 315 VA Nominal(L-L)voltage/rangez 240 V/211-264 V 208 V/183-229 V Battery'", and the Enphase Enlighten'" monitoring Maximum continuous output current 1.31 A(240 VAC) 1.51 A(208 VAC) and analysis software. Nominal frequency 60 Hz Extended frequency range 47-68 Hz The IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit3 12(240 VAC) 10(208 VAC) Overvoltage class AC port III undergo over a million hours of power-on testing, AC port backfeed current 18 mA enabling Enphase to provide an industry-leading Power factor setting 1.0 warranty of up to 25 years. Power factor(adjustable) 0.85leading...0.85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.5% 97.0% MECHANICAL DATA Ambient temperature range -400C to+60°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with optional Q-DCC-5 adapter) Easy to Install Connector type(IQ7X-96-B-US) Friends PV2,may require adapters for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 Lightweight and simple PV2 to UTX:order ECA-S20-S25 Faster installation with improved,lightertwo-wire cabling Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Built-in rapid shutdown compliant(NEC 2014&2017) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Efficient and Reliable Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Optimized for high powered 96 cell*modules Environmental category/UV exposure rating NEMA Type 6/outdoor Highest CEC efficiency of 97.5% FEATURES Q More than a million hours of testing Communication Power Line Communication(PLC) FQ_7X ,;, Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options Wi UL listed Compatible with Enphase IQ Envoy " Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Smart Grid Ready Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Complies with advanced grid support,voltage and CAN/CSA-C22.2 NO.107.1-01 frequency ride-through requirements This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) U1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase.com/en-us/support/module-compatibility. *The IQ 7X is required to support 96-cell modules. 2.Nominal voltage range can be extended beyond nominal if required bythe utility. 3.Limits mayvary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com " ENPHASE® " ENPHASE@ ,u �aiiimoreaboutEnphaseofferings,visitenphase.com ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-11-19 IQ Combiner 4/4C Data Sheet Enphase Networking MODEL NUMBER IQ Combiner 4 IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%) X-IQ-AM1-240-4 and consumption monitoring(±2.59%).Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to X2-IQ-AM1-240-4(IEEE 1547:2018) deflect heat. IQ Combiner 4C IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI C12.20±0.5%) X-IQ-AM1-240-4C and consumption monitoring(±2.59%).Includes Mobile Connect cellular modem(CELLMODEM-M1-06-SP-05),a plug-and-play IQ Combiner 4/4C The IQ Combiner 4/4C with IQ Gateway and X2-IQ-AM1-240-4C(IEEE 1547:2018) industrial-grade cell modernforsystems up to 60 microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,where there is adequate cellular service in the installation area.)Includes a silver solar shield to match the integrated LTE-M1 cell modem (included IQ Battery and IQ System Controller and to deflect heat. only with IQ Combiner 4C) consolidates ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Supported microinverters IQ6,IQ7, and IQ8.(Do not mix IQ6/7 Microinverters with IQ8) interconnection equipment into a single Communications Kit enclosure. It streamlines IQ Microinverters and COMMS-CELLMODEM-Ml-06 IncludesCOMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 4G based LTE-M1 cellular modem with 5-year Sprint data plan storage installations by providing a consistent, CELLMODEM-M1-06-AT-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. ENPHASE pre-wired solution for residential applications. BRK-1OA-2-240V Circuit breaker,2 pole,10A,Eaton BR210 BRK-15A-2-240V Circuit breaker,2 pole,15A,Eaton BR215 It offers up to four 2-pole input circuits and BRK-20A-2P-240V Circuit breaker,2 pole,20A,Eaton BR220 BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support Eaton BR series busbar assembly. BRK-20A-2P-240V-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support q XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C �j XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C(required for EPLC-01) *1 X-IQ-NA-HD-125A Hold-down kit for Eaton circuit breaker with screws n Consumption monitoring CT A pair of 200A split core current transformers Smart (CT-200-SPLIT/CT-200-CLAMP) ELECTRICAL SPECIFICATIONS Includes IQ Gateway for communication and control Rating Continuous duty Includes Mobile Connect cellular modem (CELLMODEM-Ml-06-SP-05),included only with System voltage 120/240VAC,60 Hz IQ Combiner 4C Eaton BR series busbar rating 125A Includes solar shield to match Enphase IQ Battery Max.continuous current rating 65A aesthetics and deflect heat Max.continuous current rating(input from PV/storage) 64A Supports Wi-Fi,Ethernet,or cellular connectivity Max.fuse/circuit rating(output) 90A Optional AC receptacle available for PLC bridge Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) Provides production metering and consumption Max.total branch circuit breaker rating(input) 80A of distributed generation/95A with IQ Gateway breaker included monitoring IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway Simple MECHANICAL DATA X IQ AMl 240 4C Dimensions(WxHxD) 37.5 cm x 49.5 cm x 16.8 cm(14.75 in x 19.5 in x 6.63 in).Height is 53.5 cm(21.06 in)with mounting brackets. i Mounts on single stud with centered brackets X2-IQ-AM1-240-4C(IEEE 1547:2018) Supports bottom,back and side conduit entry weight 7.5 kg(16.51bs) Allows up to four 2-pole branch circuits for 240VAC Ambient temperature range -400Cto+460C(-40°Fto 115°F) plug-in breakers(not included) Cooling Natural convection,plus heat shield 80A total PV or storage branch circuits Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20A to 50A breaker inputs:14 to 4 AWG copper conductors Reliable 60A breaker branch input:4 to 1/0 AWG copper conductors Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground:14to 1/0 copper conductors Durable N RTL-certified N EMA type 3R enclosure Always follow local code requirements for conductor sizing. Five-year limited warranty Altitude Up to 3,000 meters(9,842 feet) _ Two years labor reimbursement program coverage INTERNET CONNECTION OPTIONS included for both the IQ Combiner SKU's Integrated Wi-Fi IEEE802.11b/g/n �X-IQ-AM1-240-4 UL listed Cellular CELLMODEM-M1-06-SP-05,CELLMODEM-M1-06-AT-05(4G based LTE-M1 cellular modem). Notethatan Mobile Connect X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with cellular modem is required forall Enphase Energy System installations. X2-IQ-AM1-240-4(IEEE 1547:2018) IEEE 1547:2018 U -L 1741SB,3rd Ed. ( ) Ethernet Optional,IEEE 802.3,Cat5E(or Cat6)UTP Ethernet cable (not included) COMPLIANCE O Compliance,IQ Combiner UL Rule 21(UL 1741 SA) IEEE 1547:2018-UL 1741-SB,311 Ed.(X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No.107.1,Title 47 CFR,Part 15,Class B,ICES 003 LISTED Production metering:ANSI C12.20 accuracy class 0.5(PV production) EN P H AS E. Consumption metering:accuracy class 2.5 To learn more about Enphase offerings,visit enphase.com Compliance,IQ Gateway UL 60601-1/CANCSA 22.2 No.61010-1 IQ-C-4-4C-DS-0103-EN-US-12-29-2022 ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 4/4C,and other names are trademarks of Enphase Energy,Inc.Data subject to change. IQ-C-4-4C-DS-0103-EN-US-12-29-2022 RSTC Enterprises, Inc. 2214 Heimstead Road Eau Claire, WI 54703 S %ALADECK 715-830-9997 FLASHED PV ROOF-MOUNT COMBINERANCLOSURES Outdoor Photovoltaic Enclosures 0799 Series Composition/Cedar Roof System ETL listed and labeled Report#3171411 PRT-002 Revised May, 2018 • UL50 Type 3R, 11 Edition Electrical equipment enclosures • CSA C22.2 No. 290 Nema Type 3R - • Conforms to UL 1741 Standard 0799 Series Includes: Sola Deck 0799-25 0799-2 Wire size 2/0-14 0799-5 Wire size 14-6 0799-D Wire size 14-8 Models available in Grey, Black or Stainless Steel Basic Specifications Material options: • Powder coated, 18 gauge galvanized 90 steel (1,100 hours salt spray) • Stainless steel Sola Deck 0799-5G Process- Seamless draw (stamped) Flashing - 15.25"x 17.25" Height- 3" Cavity- 255 Cubic inches Base Plate: • Fastened to base using toggle fastening system • 5 roof deck knockouts o Knockout sizes: (3) .5", (1) .75" and (1) 1" • 8", 35mm slotted din rail • Ground Block Passthrough and combiner kits are available for either Sola Deck 0799-DG - AC or DC applications. Fm'TeN Product compliance: No Data Powering Business Worldwide pe.eaton.com © 2016 Eaton. All rights reserved. Eaton general duty cartridge fuse safety switch DG222NRB UPC:782113144221 Dimensions: • Height: 14.38 IN • Length: 14.8 IN • Width: 9.7 IN Weight:10 LB Notes:Maximum hp ratings apply only when dual element fuses are used. 3-Phase hp rating shown is a grounded B phase rating, UL listed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: General duty, cartridge fused • Amperage Rating: 60A • Enclosure: NEMA 313 • Enclosure Material: Painted galvanized steel • Fuse Class Provision: Class H fuses • Fuse Configuration: Fusible with neutral • Number Of Poles: Two-pole • Number Of Wires: Three-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG222NRB Certifications: • UL Listed © 2016 Eaton. All rights reserved. pe.eaton.com :T•M JI'I Eaton general duty non-fusible safety switch ) -° DG221 U R B UPC:7821 1 31 20232 Dimensions: • Height: 10.81 IN • Length: 6.88 IN • Width: 6.38 IN Weight:6 LB Notes:WARNING! Switch is not approved for service entrance unless a neutral kit is installed. Warranties: • Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Specifications: • Type: Non-fusible, single-throw • Amperage Rating: 30A • Enclosure: NEMA 3R, Rainproof • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non-fusible • Number Of Poles: Two-pole • Number Of Wires: Two-wire • Product Category: General duty safety switch • Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution • Eaton Specification Sheet - DG221 URB Certifications: • UL Listed Product compliance: No Data Snap rack- UR-40 SnapNrack Ultra Rail - UR-60 - . . . . types. Rail Solar Mounting Solutions features two rail profiles; UR-40 is a lightweight rail profile that is suitable geographic Ultra Rail - • • • - - • •s. duty rail mpatible with all . . module The Entire System is a Snap to Install • New Ultra Rail Mounts include snap-in brackets for attaching rail • Compatible with all the SnapNrack Mid Clamps and End Clamps customers love • Universal End Clamps and snap-in End Caps provide a clean look to the array edge Unparalleled Wire Management ' • Open rail channel provides room for running wires resulting in a long-lasting quality install �L • Industry best wire management offering includes Junction Boxes, Universal Wire Clamps, MLPE Attachment Kits, and Conduit Clamps • System is fully bonded and listed to UL 2703 The Ultimate Value in Rooftop Solar Standard Industry leading Wire Mounts available for all Heavy Duty UR-60 Rail Management • • • • types • UR-60 rail profile provides increased span capabilities for high wind speeds and snow Single loads " • • • • • • • Taller, stronger rail profile includes profile- Clamps & Accessoriesspecific rail splice and end cap are compatible with • All existing mounts, module clamps, and accessories are retained for the same great both rafil profiles install experience InstallingStart UltraHaiiToday '4 Quality. Innovative . Superior. RESOURCES snapnrack.com/resources SnapNrack Solar Mounting Solutions are engineered to optimize material use and DESIGN snapnrack.com/conflgurator labor resources and improve overall installation quality and safety. WHERE TO BUY snapnrack.com/where-to-buy P70 L � structural ENGINEERS July 7, 2020 `o011111nui������ SnapNrack LICENSED 775 Fiero Lane, Ste. 200 = OFESSIONAL San Luis Obispo, CA 93401 _ ENGINEER p .06/30/2022. TEL: (877) 732-2860 52544 �Q Attn.: SnapNrack-Engineering Department /111 IIM'00��```�� Re: SnapNrack pre-engineered PV racking systems: I hereby certify that this plan,specification,or report was RL Universal System(Report#2019-02916A.01 and B.01)prepared by me or u der my direct supervision and that • am a duly Licensed rofessional Engineer under the laws of • S200 Ground Mount System(Report#2017-00240-D.02) the state of Minne o . • UR40 Railed System(Report#2017-03227.11) Signature: • UR60 Railed System(Report#2018-11940.03) Typed or Printed ffame: Paul Zacher Date: 07r07/2020 License Number: .52.54 Subject: Engineering certification for the State of Minnesota. PZSE, Inc. -Structural Engineers has provided engineering and span tables as presented in the above referenced reports. All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2020 Minnesota Building Code, by Minnesota Department of Labor& Industry 3. 2018 International Building Code, by International Code Council, Inc. 4. 2018 International Residential Code, by International Code Council, Inc. 5. AC428 Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV) Panels, November 1, 2012, by ICC-ES 6. Aluminum Design manual 2015, by The Aluminum Association, Inc. 7. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council This letter certifies that the design criteria and design methodology for the SnapNrack product span tables are in compliance with the above codes. Please refer to the system specific Engineering Certification Reports (listed above)for system specific design criteria and limitations. If you have any questions on the above, do not hesitate to call. Prepared by: PZSE, Inc. —Structural Engineers Roseville, CA 1478 Stone Point Drive,Suite 190, Roseville, CA 95661 916.961.3960 F 916.961.3965 W www.pzse.com Experience I Integrity I Empowerment Certification Details SnapNrack Ultra Rail system has been evaluated by Underwriters Laboratories(UL)and Listed to UL/ANSI Standard 2703 for Grounding/Bonding, Mechanical Loading,and Fire Classification. Grounding/Bonding The Ultra Rail system has been designed in compliance with UL Standard 2703 Section 9.1 Exception,which permits accessible components that are not part of the fault current ground path to not be electrically bonded to the mounting system (e.g.roof attachments,array skirt,etc.). For more details on the integrated grounding functionality see the Grounding Specifications section. This racking system may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. See the Grounding Specifications for the list of modules tested with the Ultra Rail system for integrated grounding. Ground Lugs have been evaluated to both UL 467 and UL 2703 Listing requirements. Ultra Rail has been listed with a number of Module Level Power Electronic(MLPE) devices.A complete list can be found in the Grounding Specifications section. The mounting system Bonding Listing is only valid when installed with a Non-Separately Derived PV system.The PV system is required to have a direct electrical connection to another source,such as connecting to the grid via a grid interactive inverter. SnapNrack recommends that bare copper never come into contact with aluminum. Mechanical Loading The Ultra Rail system is Listed for mechanical loading for different load ratings depending on the mounting configuration and PV module installed. For more details on the mechanical loading details see the Mechanical Loading Specifications section. SnapNrack engineered systems should only be used with SnapNrack components and hardware.Any application outside of those specified in this Installation Manual and the Structural Engineering Report may void the warranty and structural certification could become invalid. If the module clamps have been engaged and need to be loosened and reengaged, SnapNrack recommends moving the module frame 3mm to engage the bonding pin in a new location. The UL Listing covers mechanical load ratings for the various span lengths, module orientations and positive,negative,and side load ratings.These values can be found in the Mechanical Loading Specifications section. SnapNrack recommends a periodic re-inspection of the completed installation for loose components, loose fasteners,and any corrosion, such that if found,the affected components are to be immediately replaced. Fire The Ultra Rail system has been evaluated for a Class A System Fire Classification for a Steep-Sloped Roof(>_2:12 pitch) using Type 1 and Type 2 modules. In order to maintain the System Classification, modules are clamped to the mounting rails between 0 and 12 inches from the top and bottom edges of the module. The Ultra Rail system has been evaluated for a Class A System Fire Classification for a Low-Sloped Roof(< 2:12 pitch)using Type 1 and Type 2 modules. In order to maintain the System Classification,modules are clamped to the mounting rails be- tween 0 and 16.3 inches from the top and bottom edges of the module. The optional Array Skirt accessory has also been evaluated and the Ultra Rail system will maintain the Class A System Fire Classification detailed above if installed with the Skirt. Because the system was tested at 5 inches above the test roof fixture Ultra Rail can be installed without any height restric- tions and will maintain the Class A System Fire Classification. See Rail Installation section for potential module-specific height restrictions due to module temperature. Grounding . snapnrack.com . snapnrack.com Ultra Rail has been tested with the following UL Listed modules: Manufacturer Model The Ultra Rail System employs top-down clamps which have been evaluated for frame-to-system bonding,at specific mounting Q.PLUS BFR-G4.1/TAA-XXX Q.PEAK DUO-L-G7.3-XXX torques and with the specific modules listed below. Q.PLUS G4-XXX Q.PEAK DUO-L-G6-XXX Ultra Rail has been tested with the following UL Listed module series:The Ultra Rail System employs top-down clamps which Q.PLUS GY-XXX Q.PEAK DUO-L-G6.2-XXX have been evaluated for frame-to-system bonding,at specific mounting torques and with the specific module series listed below.All wattage values are covered. Q.PLUS BFR-GY-XXX Q.PEAK DUO-L-G6.3-XXX Q.PRO BFR-G4-XXX Q.PEAK DUO-L-GB-XXX ModelManufacturer Q.PRO BFR-G4.I-XXX Q.PEAK DUO-L-G8.I-XXX DNA-120-MF23-XXX DNA-120-MF26-XXXW Q.PRO BFR-G4.3-XXX Q.PEAK DUO-L-G8.2-XXX Aptos Solar DNA-120-BF23-XXX DNA-144-MF26-XXXW Q.PRO BFR-GY-XXX Q.PEAK DUO-L-G8.3-XXX DNA-144-MF23-XXX DNA-120-BF26-XXXW Q.PRO BLK-GY-XXX Q.PEAK DUO-G5/SC-XXX DNA-144-BF23-XXX DNA-144-BF26-XXXW I Q.PRO G4-XXX Q.PEAK DUO-BLK-G5/SC-XXX Boviet Solar BVM6610P-XXX BVM6612P-XXX I Q.PRO GY-XXX Q.PEAK DUO-G6+/SC-XXX BVM6610M-XXX BVM6612M-XXX Q.PRO GY/SC-XXX Q.PEAK DUO-BLK-G6+/SC-XXX CS6K-XXX-M CS3K-XXX-P Q.PEAK DUO-GS-XXX Q.PEAK DUO BLK-G6+/AC-XXX CS6K-XXX-M-SD CS3K-XXX-MS I Q.PEAK DUO-BLK-GS-XXX Q.PEAK DUO-ML-G9-XXX CS6K-XXX-P CS3U-XXX-MS I Q.PLUS DUO-GS-XXX Q.PEAK DUO-BLK-ML-G9-XXX CS6K-XXX-P-SD CS3U-XXX-P Q.PEAK DUO-G7-XXX Q.PEAK DUO-G5/TS-XXX CS6K-XXX-MS CS1K-XXX-MS Q.PEAK DUO-BLK-G7-XXX Q.PEAK DUO BLK-G5/TS-XXX Canadian Solar CS6P-XXX-M CS1H-XXX-MS Q.PEAK DUO-G7.2-XXX Q.PEAK DUO-G6/TS-XXX CS6P-XXX-P CS1H-XXX-MS-AB Q.PEAK DUO-G6+-XXX Q.PEAK DUO BLK-G6/TS-XXX CS6P-XXX-P-SD CS3W-XXX-P Hanwha Q Cells Q.PEAK DUO-BLK-G6+-XXX Q.PEAK DUO-G6+/TS-XXX CS6V-XXX-M CS3N-XXX-MS I Q.PEAK DUO-G6-XXX Q.PEAK DUO BLK-G6+/TS-XXX CS6V-XXX-P CS1Y-XXX-MS Q.PEAK DUO-BLK-G6-XXX Q.PEAK DUO XL-G9.2-XXX CS6X-XXX-P Q.PEAK DUO-G8+-XXX Q.PEAK DUO XL-G9.3-XXX CertainTeed CTXXXHCII-06 Q.PEAK DUO-BLK-G8+-XXX Q.PEAK DUO XL-G9.3/BFG-XXX* CHSM6612M-XXX CHSM72M-HC-XXX*(Astro 4) I Q.PEAK DUO-GB-XXX Q.PEAK DUO XL-G10.2-XXX Chint Solar CHSM6612M(BL)-XXX CHSM72M-HC-XXX*(Astro 5) I Q.PEAK DUO-BLK-GB-XXX Q.PEAK DUO XL-G10.3/BFG-XXX* CHSM6612M/HV-XXX I Q.PLUS L-G4-XXX Q.PEAK DUO XL-G10.3-XXX DH-M760B-XXXW DH-M760E-XXXW* Q.PLUS L-G4.I-XXX Q.PEAK DUO XL-G10.c-XXX Dehui Solar DH-M760W-XXXW DH-M772F-XXXW* I Q.PLUS L-G4.2-XXX Q.PEAK DUO XL-G10.d-XXX DH-M772W-XXXW Q.PEAK L-G4.I-XXX Q.PEAK DUO L-G8.3/BFG-XXX* ET-P660XXXBB P660XXXWB/WW Q.PEAK L-G4.2-XXX Q.PEAK DUO L-G8.3/BGT-XXX* ET-P660XXXWB P660XXXWWG Q.PLUS DUO-L-GS-XXX Q.PEAK DUO ML-GIO-XXX ET Solar ET-P660XXXWW M660XXXBB Q.PLUS DUO-L-G5.I-XXX Q.PEAK DUO BLK ML-G10+-XXX ET-P660XXXWWG M660XXXWW Q.PLUS DUO-L-G5.2-XXX Q.PEAK DUO ML-G10+-XXX Q.PEAK BLK-G3.I-XXX Q.PEAK BLK-G4.I-XXX Q.PLUS DUO-L-G5.3-XXX Q.PEAK DUO BLK ML-GIO-XXX Q.PEAK G3.1-XXX Q.PEAK BLK-G4.1/TAA-XXX Q.PEAK DUO-L-G5.2-XXX Q.PEAK DUO ML-G10.a+-XXX Q.PLUS BFR-G3.I-XXX Q.PEAK G4-XXX Q.PEAK DUO-L-G5.3-XXX Q.PEAK DUO BLK ML-G10.a+-XXX B.LINE PLUS BFR-G4.I-XXX Q.PEAK G4.1-XXX I Q.PEAK DUO-L-G7-XXX Q.PEAK DUO ML-G10.a-XXX Hanwha Q Cells B.LINE PRO BFR-G4.I-XXX Q.PEAK G4.1/MAX-XXX Q.PEAK DUO-L-G7.I-XXX Q.PEAK DUO BLK ML-G10.a-XXX Q.BASE GY-XXX Q.PEAK G4.1/TAA-XXX I Q.PEAK DUO-L-G7.2-XXX Q.PEAK BFR-G4-XXX Q.PLUS BFR-G4-XXX Hanwha SolarOne I HSL60P6-PB-2-XXXQ HSL60P6-PB-4-XXXQ Q.PEAK BFR-G4.I-XXX Q.PLUS BFR-G4.I-XXX Heliene 60M-XXX 72M-XXX 60P-XXX 72P-XXX 62 63 Grounding . snapnrack.com . snapnrack.com ModelManufacturer HiS-MXXXRG HiD-SXXXRG LGXXXNIC-V5 LGXXXNIK-B6 HiS-SXXXRG HiA-SXXXMS LGXXXNIW-V5 LGXXXN2W-E6 Hyundai HiS-SXXXRW HiS-SXXXXY LG LGXXXN2T-V5 LGXXXN2T-E6 HiS-MXXXMG HiS-SXXXYI I LGXXXN2T-J5 LGXXXNIK-E6 HiS-SXXXMG I I LGXXXNIT-V5 JAM6-60-XXX/SI JAM72SO9-XXX/PR I LR6-60-XXXM LR4-60HPB-XXXM JAPE-60-XXX/3BB JAM72S10-XXX/MR LR6-60BK-XXXM LR4-60HIB-XXXM JAM60SO9-XXX/PR JAM72S10-XXX/PR LR6-60HV-XXXM LR4-60HPH-XXXM JA Solar JAM60S10-XXX/MR JAM72S12-XXX/PR LR6-60PB-XXXM LR4-60HIH-XXXM JAM60S10-XXX/PR JAP6(k)-72-XXX/4BB I Longi LR6-60PE-XXXM LR6-60HIH-XXXM JAM60S12-XXX/PR JAM60S17-XXX/MR I LR6-60PH-XXXM LR6-60HIB-XXXM JAP72S01-XXX/SC I I LR6-60HPB-XXXM LR4-72HPH-XXXM JKMXXXM-60 JKMXXXP-72 LR6-60HPH-XXXM JKMXXXM-60L JKMXXXP-72-V MSEXXXS05T MSEXXXSQ4S JKMXXXM-60HL JKMXXXPP-72 MSEXXXS05K MSEXXXSR8K JKMXXXM-60HBL JKMXXXPP-72-V I I MSEXXXSQ5T MSEXXXSR8T JKMXXXP-60 JKMSXXXP-72 I I MSEXXXSQ5K MSEXXXSR9S Jinko Solar JKMXXXP-60-J4 JKMXXXM-72HL-V MSEXXXMM4J MSE60AXXX Mission Solar JKMXXXP-60-V JKMXXXM-72HL-TV MSEXXXMM6J MSEXXXTS60 JKMXXXP-60B-J4 JKMXXXM-72HBL MSEXXXS06W MSEXXXSX5K JKMXXXPP-60 JKMXXXM-6TL3-B MSEXXXSO4J MSEXXXSX5T JKMXXXPP-60-V JKMXXXM-6RL3-B I MSEXXXS06J MSEXXXSX6S JKMXXXM-72 JKMXXXM-7RL3-V I I MSEXXXS06S MSEXXXSX6W JKMXXXM-72L-V JKMXXXM-7RL3-TV USNEA-XXXM3-60 USNEA-XXXM3-72 Kyocera KUXXX-6YYY KUXXX-8YYY Next Energy Alliance USNEA-XXXM3B-60 USNEA-XXXM3B-72 LGXXXNIC-A5 LGXXXAIC-V5 I VBHNXXXKAOI VBHNXXXSA18 LGXXXNIK-A5 LGXXXMIC-L5 I VBHNXXXKA02 VBHN325SA17E LGXXXQIC-A5 LGXXXMIK-L5 I I VBHNXXXSA16 VBHXXXRA18N LGXXXQIK-A5 LGXXXNIC-N5 Panasonic VBHNXXXKA03 VBHXXXRA03K LGXXXSIC-A5 LGXXXNIK-L5 VBHNXXXKA04 EVPVXXX(K) LGXXXN2C-B3 LGXXXNIK-A6 VBHNXXXSA17 LGXXXN2W-B3 LGXXXNIC-A6 I Phono Solar I PSXXXM-20/U PSXXXMH-20/U LG I LGXXXNIC-G4 LGXXXNIW-A6 I RECXXXPE RECXXXPE72XV LGXXXNIK-G4 LGXXXQIC-A6 I RECXXXPE-BLK RECXXXTP2M 72 LGXXXSIC-G4 LGXXXQIK-A6 RECXXXTP RECXXXTP2M 72 BLK LGXXXN2C-G4 LGXXXMIK-A6 RECXXXTP-BLK RECXXXTP2M 72 BLK2 LGXXXN2K-G4 LGXXXMIC-A6 RECXXXTP IQ RECXXXTP2SM 72 LGXXXN2W-G4 LGXXXAIC-A6 I REC RECXXXTP2 RECXXXTP2SM 72 BLK LGXXXS2C-G4 LGXXXQAC-A6 I I RECXXXTP2-BLK RECXXXTP2SM 72 BLK2 LGXXXS2 W-G4 LGXXXQAK-A6 I R ECXXX N P R ECXXXAA RECXXXTP2M RECXXXTP3M RECXXXTP72 RECXXXNP2 RECXXXPE72 64 65 Grounding . snapnrack.Com . snapnrack.Com Manufacturer Model Ultra Rail has been tested with the following Module Level Power Electronic (MLPE) devices: Renesola JCXXXM-24/Bb JCXXXM-24/BBh XXXM-2 / SSGX-24/ I The UR-40 and UR-60 mounting systems have been tested with the following UL/NRTL Listed Module Level Power Electronic SLAXXX (MLPE) Devices.The back plates of the MLPEs have been evaluated for bonding to UR-40 and UR-60 rail through the MLPE SLAXXX-P SSGXXX-P Attachment Kit. SSAXXX-M S I LXXX NT SSAXXX-P SILXXXHL AP Smart RSD-S-PLC Silfab SILXXXBL SILXXXBK Celestica International DG-006-FO01201x DG-006-F001401x SILXXXML SILXXXHC Delta Electronics GPI00010105 SILXXXNL SILXXXNU I C250 IQ7-60-2-US SLGXXX-M SILXXXNX I M215 I07-60-B-US SLGXXX-P I Enphase M250 I07PLUS-72-2-US Solaria PowerXT-XXXR-PX Solaria PowerXT-XXXR-PM I06-60-2-US I07PLUS-72-B-US Solaria Solaria PowerXT-XXXR-BX Solaria PowerXT-XXXR-PM-AC I06PLUS-72-2-US Solaria PowerXT-XXXR-AC Solis-RSD-1G Solis-MLRSD-R2-1G SolarWorld I SWXXX-Mono SWXXX-Mono XL I GinlOng Technologies Solis-MLRSD-RI-1G M VX-XXX-60-5-701 O PT-XXX-60-4-1 BO P300-5NC4ARS P40 Suniva MVX-XXX-60-5-7B1 OPT-XXX-60-4-800 P320-5NC4ARS P485 OPT-XXX-60-4-100 OPT-XXX-60-4-8BO SPR-EYY-XXX SPR-XYY-XXX P370-5NC4AFS P505 Sunpower I SPR-XYY-XXX SPR-PI7-XXX-COM I P400-5NC4AFS P730 SPR-EYY-XXX SPR-PI9-XXX-COM SolarEdge P320 P800p SST-XXXM3-60 SST-XXXM3-72 P340 P850 SunSpark P370 P860 SST-XXXM3B-60 SST-XXXM3B-72 TP660M-XXX TP672M-XXX P400 P950 Talesun TP660P-XXX TP672P-XXX P401 Tesla I TXXXS TXXXH I SMA RSB-2S-US-10 TSM-XXXDD05(II) TSM-XXXPD05.05S I TS4-R-F TS4-R-S-DUO TSM-XXXDD05A.05(II) TSM-XXXPD05.08 TS4-R-M TS4-A-F TSM-XXXDD05A.08(II) TSM-XXXPD05.082 TS4-R-O TS4-A-2F TSM-XXXDD05A.082(II) TSM-XXXPD05.08D Tigo TS4-R-S TS4-A-0 Trina I TSM-XXXPA05 TSM-XXXPD05.OSS I TS4-R-M-DUO TS4-A-S TSM-XXXPA05.05 TSM-XXXDD06M.05(ll) I TS4-R-0-DUO TSM-XXXPA05.08 TSM-XXXDEI5H(ll) Vikram SOMERA VSMHBB.60.XXX.05 TSM-XXXPD05 TSM-XXXDEI5M(ll) TSM-XXXPD05.002 TSMXXXDD05H.05(II) Notes: TSM-XXXPD05.05 TSMXXXDE06X.05(II) Yingli YLXXXA-29b YLXXXP-29b AP Smart RSD-S-PLC, Ginlong Solis-MLRSD-RI-1G and Solis-MLRSD-R2-1G,and all Tigo models have not been investigated for I bonding since the enclosures are constructed entirely of polymeric materials. ZNShine ZM6-60-XXX/M ZXM6-NH144-XXXM The SolarEdge P320 and P370 models are both frame mount and rail mount.All other PXXX series models are rail mount. ZXM6-NH120-XXXM 66 67 DESCRIPTION: DRAWN BY: DESCRIPTION: DRAWN BY: SNAPNRACK, ULTRA RAIL COMP KIT mwatkins SnapWach- SNAPNRACK, ULTRA RAIL COMP KIT mwatkins SnapNmck- REVI SI ON: Solar Mounting Solutions REVISION: Solar Mounting Solutions PART NUMBER(S): PART NUMBER(S):B 585 MARKET PHONE(415)580 8900 FAX(4 5)580 8902A 84105 USA B 585 MARKET SP RONE(485)580 8900•FAX(4 5)580 8902A 84105 USA SEE BELOW THE INFORMATON N TH S DRAWN S CONE DENTAL AND PROPRIETARY ANY SEE BELOW WRITTEN CONSENTOFSUNRUN SOUTH LITC. WRITTEN CONSENTOFSUNRUN SOUTH UMBRELLA L FOOT PROPERTIES SKU DESCRIPTION 242-01219 ULTRA RAIL UMBRELLA L FOOT, SILVER 242-01220 ULTRA RAIL UMBRELLA L FOOT, BLACK 1.37 .38 .30 ® 1.00 SLOT 3.25 2.78 1.78 1.62 2 �1.50� 2 COMP FLASHING PROPERTIES 3 SKU DESCRIPTION 232-01375 COMP FLASHING, 9" X 12", BLACK ALUM ® 232-01376 COMP FLASHING, 9" X 12", SILVER ALUM io 01.00 O O 11.75 o 0 ITEM QTY PART NUMBER PARTS LIST DESCRI PTI ON 4.201050 1 1 242-92266 SNAPNRACK, UMBRELLA LAG, TYPE 3, 41N, SS 2 1 242-01219, 242-01220 SNAPNRACK, ULTRA FOOT FOR U FLASHING, SILVER/ BLACK 3 1 232-01375, 232-01376 SNAPNRACK, COMP FLASHI NG, 91 N X 121 N, SI LVER/ BLACK ALUM MATERIALS: 6000 SERIES ALUMINUM, STAINLESS STEEL, RUBBER 0.35 DESIGN LOAD (LBS): 802 UP, 1333 DOWN, 356 SIDE 3.25 ULTIMATE LOAD (LBS): 2005 UP, 4000 DOWN, 1070 SIDE TORQUE SPECIFICATION: 12 LB-FT CERTI FICATI ON: UL 2703, FI LE E359313; WI ND-DRI VEN RAI N TEST FROM UL SUBJECT 2582 8.75 .45 WEIGHT (LBS): 0.80 ALL DIMENSIONS IN INCHES