Loading...
HomeMy WebLinkAboutH- Series Heater 101HAYWARKY Universal H -Series POOL AND SPA HEATERS Right for so many reasons. Perfect for pp so many applications. Il: �tJr�W'0'90 0 vz, °cos *° �w Owl kw I Aw Total System: Pumps I Filters I Heating I Cleaners I Sanitization I Automation I Lighting I Safety I White Goods Hayward' Universal H -Series Heaters: Energy efficient and universal fit for added convenience . .j►Py W ARO Hayward is always looking for ways to make pool and spa ownership z z as affordable and effortless as possible. Our Universal H-Series pool Oi����►1 and spa heaters combine advanced technology with universal-fit flexibility, �10S *� making them a smart choice for virtually any new installation or system upgrade. They deliver state-of-the-industry performance, save up to 18% on energy costs, have extremely low NOx emission levels and a legendary reputation for durability. They're offered in 150,000, 200,000, 250,000, 300,000, 350,000 and 400,000 BTU/hr. models. Easy installation, simple operation. A choice of left-side or right-side electric, low-profile appearance and front-panel gas and water connections gives Universal only access required for both installation H-Series heaters unprecedented installation and service — ensures compatibility with flexibility. This enhanced adaptability— virtually all new or existing systems and coupled with a lightweight design, a modern equipment pad configurations. Exclusive me to Universal , o H-Series STANDARD Cupro Superior Hydraulic State-of-the-Art Finn Dual Voltage Heaters Nickel Heat Exchanger Performance Plate Heat Exchanger Installation is simplified Totally Managed Flow Industry-leading hydraulic State-of-the-industry Finn with voltage that adapts provides exceptional performance saves Plate heat exchanger with to either 110V or 220V. corrosion resistance and energy by reducing special V-groove design erosion protection.Ideal for circulation pump run time. for faster heating and today's salt-based electronic longer life. chlorination systems. re - AV r�_^r--n • i Q♦ �. J+.1 a♦ a 1� H400FD H250FD 4I II mom Environnn Friendly Universal Wiring Hot-Surface Silicon Digital LED Control Panel Insulated FireTile° Low NOx Emissions Junction Boxes Nitride Ignition System Electronic control Combustion Chamber Environmentally High and low voltage Exclusive silicon nitride display maintains water Unlike older forms of responsible;complies connections are easy and ignition system for temperature;monitors insulation,FireTile securely with all current California convenient with left and dependable lighting and heater performance with traps the heat,delivering and Texas air quality right side junction boxes. reliable operation. self-diagnostic capability. the most performance emission standards. from each BTU. Selecting the correct size Specifications and H-Series heater: Dimensions: For Your Swimming Pool Universal H-Series Heater Determine your pool's surface area in square feet: 400,000 350,000 300,000 250,000 200,000 150,000 'A B L r 36' 33' 30' 28' 25' 21" L R W i• 29Y2' 29Y2' 29Y2' 29Y2' 29Y2' 29Y2" 24' 24" 24' 24" 24' 24" Area=(A+B)xLx.45 Area=RxRx3.14 Area=LxW 2"x2Y2' 2"x2Y2' 2"x2Y2' 2"x2Y2' 2"x2Y2 2"x2Y2" Cupro Cupro Cupro Cupro Cupro Cupro N.71 Nickel Nickel Nickel Nickel Nickel Nickel In this table,locate the surface area that MODEL SURFACE AREA s equal to,orjust greaterthan,the pool's 8" 8' 8' 6' 6' 6" H400 1,200 surface area.To the left of this number is the H350 1,050 160 158 145 134 123 110 appropriate H-Series model that will fit the H300 900 selected area. onnection 3/4 3/4 3/4 3/4 3/4 3/4 at Heater H250 750 For indoor pool installations,divide the pool's H2O0 600 surface area by 3. Hill 50 450 Table is based on a30°F temperature nse,3l�mph average Millivolt Heaters wind velocity and elevation of up to 2,000 feet above sea level. 250,000 200,000 150,000 For Your Spa or Hot Tub ' 27" 24Y2" 21Y2" 27Y2" 27Y2" 27Y2" Determine your spa capacity in gallons(surface area x average depth x 7Y2). 28Y2" 28Y2" 28Y2" The reference table lists the time required in minutes to raise the temperature of the 1 Y2"x 2" 1 Y2"x 2" 1 Y2"x 2" spa/hot tub by 30`F.In the table below,locate the column with the spa/tub size in gallons that is closest to yours.Select the desired time to raise the spa/hot tub temperature 30`F, Cupro Nickel Cupro Nickel Cupro Nickel read to the left and select the appropriate H Series model. 7" 7" 6" This guide can be adjusted for other temperature rises.For example,if you desire a 150F 17Ya" 151/4" 14" increase in temperature,simply divide the time for 30`F rise by the ratio of 30/15,or 2. 144 141 131 Note:Heat lost and/or heat absorbed by spa walls or other objects will add to the time r 3/4" 3/4" 3/4" it takes the spa to heat up. Spa sizing is based on an insulated and covered spa.Always cover your spa or hot tub H-Series heaters are available in a comprehensive range of BTU sizes for natural or propane when not in use to minimize heat loss and evaporation. gas.All units are certified by the Canadian Standards Association and carry the exclusive Hayward®warranty. SPA/TUB SIZE IN GALLONS rr 300 400 500 600 700 :ii 900 1,000 MODEL Time in Minutes to Raise Spafrub Temperature 0' H400 9 14 19 23 28 33 37 42 47022 H350 11 16 21 27 32 37 43 48 54 H300 12 19 25 31 37 44 50 56 62 H250 15 22 30 37 45 52 60 67 75 H2O0 19 28 37 47 56 66 75 84 94 H150 25 37 50 62 75 87 100 112 125 Efficiency. Performance. Innovation. Whether you want to extend your swimming season or swim year-round,Universal H-Series ® ® gives you comfort with efficiency.It's the perfect addition to your Totally Hayward®System. To take a closer look at Universal H-Series Heaters or other Hayward products,go to www.haywardpool.com or call 1-888-HAYWARD HAYWARD'' 620 Division Street I Elizabeth, NJ 07201 Hayward,Hayward Energy Solutions,Totally Hayward and h FireTile are registered trademarks of Hayward Industries,Inc. ° 02011 Hayward Industries,Inc. UTHS11